Kisiel FB, Gurumurthy GJ. Endothelial cell loss post-implantable collamer lens V4c: meta-analysis. J Cataract Refract Surg 2024; 50:420-423. [PMID: 38194352 DOI: 10.1097/j.jcrs.0000000000001389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2023] [Accepted: 12/03/2023] [Indexed: 01/10/2024]
Abstract
Endothelial cell density (ECD) loss is a noted effect of implantable collamer lens (ICL) V4c surgery. Current literature provides a wide range of values for ECD loss postsurgery, which may not be helpful in advising patients and clinicians. A meta-analysis exploring ECD loss in ICL V4c for myopia correction was undertaken. 18 studies were included in this meta-analysis with 2 subgroup analyses to account for the variability in follow-up lengths. The average ECD loss 3 months, 12 months, and 21.25 (mean) months postsurgery were 1.32% ± 1.28% ( P < .001, 95% CI, -75.158 to -1.19), 1.75% ± 2.17% ( P < .001, 95% CI, -134.09 to 14.52), and 3.84% ± 1.78% ( P < .001, 95% CI, -156.04 to -54.26), respectively. ECD loss is most pronounced 3 months postsurgery, suggesting that acute surgical trauma was the primary contributor rather than long-term lens implantation. Overall, ICL V4c is for myopia correction exhibits similar ECD loss as seen in other ICL models, thereby affirming its safety.
Collapse
Affiliation(s)
- Filip Blazej Kisiel
- From the Department of Chemical Engineering, University of Manchester, Manchester, United Kingdom (Kisiel); Department of Medicine, University of Manchester, Manchester, United Kingdom (Gurumurthy)
| | | |
Collapse
|
2
|
Wei Q, Zhou X, Chang W, Jiang R, Zhou X, Yu Z. Retinal and Choroidal Changes Following Implantable Collamer Lens V4c Implantation in High Myopia Patients-A 1-Year Follow-Up Study. Diagnostics (Basel) 2023; 13:3097. [PMID: 37835840 PMCID: PMC10572683 DOI: 10.3390/diagnostics13193097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 09/25/2023] [Accepted: 09/28/2023] [Indexed: 10/15/2023] Open
Abstract
This prospective study aimed to evaluate the impact of Visian Implantable Collamer Lens (ICL) V4c implantation on retinal and choroidal morphology in patients with high myopia. A total of 97 eyes from 52 high myopic patients who underwent ICL V4c implantation were followed up for 12 months. Preoperative and postoperative evaluations included comprehensive ophthalmic assessments and enhanced depth imaging optical coherence tomography (EDI-OCT) to analyze changes in central retinal thickness (CRT), retinal volume (CRV), choroidal thickness (ChT), total choroidal area (TCA), luminal area (LA), and choroidal vascular index (CVI). Repeated measures mixed-effects models were used for comparing pre- and postoperative measurement variables and exploring relationships among age, axial length (AL), spherical equivalent refraction (SER), and postoperative retinal and choroidal changes, with statistical significance set at p < 0.05. Follow-up assessments were conducted at various time points, with participation rates ranging from 21% to 98%. Baseline characteristics showed a median age of 26.7 years, -10.14 diopters of SER, and an AL of 27.44 mm. Throughout the 12-month follow-up, CRT and 3.0 mm CRV consistently increased compared to the baseline, with statistically significant rises observed at postoperative day 1, week 1, and month 12. Most ChT measurements, including subfoveal ChT, declined over the 12 months, except at postoperative 6 months. Horizontal and vertical TCA and LA values significantly increased throughout the follow-up, except for month 6. After surgery, both horizontal and vertical CVI parameters exhibited an increase compared to the baseline, with some changes reaching statistical significance. Correlation analysis performed by repeated measures mixed-effects models showed that no relationship was found between age, AL, and SER and changes in postoperative retinal parameters and CVI parameters. However, postoperative changes in ChT and choroidal area parameters showed a negative correlation with AL and a positive correlation with SER. Our research demonstrated that ICL V4c implantation resulted in noteworthy alterations in retinal and choroidal morphology over a 1-year follow-up period. Moreover, in patients with high myopia, individuals with longer AL and higher degrees of myopia exhibited more pronounced postoperative changes in the choroid and retina. Further studies with extended follow-up durations are necessary to comprehensively understand the long-term effects of ICL implantation on retinal and choroidal morphology and function.
Collapse
Affiliation(s)
- Qiaoling Wei
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031, China
- Ocular Trauma Center, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China
| | - Xianjin Zhou
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Department of Ophthalmology, Shanghai Children’s Medical Center, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China
| | - Weiteng Chang
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031, China
| | - Rui Jiang
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031, China
- Ocular Trauma Center, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China
| | - Xingtao Zhou
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031, China
| | - Zhiqiang Yu
- Department of Ophthalmology, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai 200031, China; (Q.W.); (X.Z.); (W.C.); (R.J.)
- Shanghai Key Laboratory of Visual Impairment and Restoration, Fudan University, Shanghai 200031, China
| |
Collapse
|
3
|
Alfonso JF, Fernández-Vega-Cueto L, Lisa C, Alfonso-Bartolozzi B, Palacios A, Madrid-Costa D. Clinical and Aberrometric Outcomes of a New Implantable Collamer Lens for Myopia and Presbyopia Correction in Phakic Patients. J Refract Surg 2023; 39:589-596. [PMID: 37675906 DOI: 10.3928/1081597x-20230726-02] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
PURPOSE To assess the clinical and aberrometric outcomes of a new Implantable Collamer Lens (EVO Viva ICL; STAAR Surgical) to correct moderate to high myopia and presbyopia. METHODS The study included 80 eyes of 40 patients who had bilateral EVO Viva ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, presbyopic add power, binocular through-focus visual acuity, total ocular spherical aberration (SA), coma aberration, and root mean square of ocular higher order aberrations (RMS HOAs) (i-Trace Aberrometer; Tracey Technologies) for a 4.5-mm pupil size were evaluated. RESULTS The mean binocular postoperative UDVA and CDVA were 0.09 ± 0.19 and 0.02 ± 0.03 logMAR, respectively. The postoperative spherical equivalent was -0.61 ± 0.54 diopters (D). The presbyopic add power reduced from +1.31 ± 0.74 D preoperatively to +0.44 ± 0.58 D after surgery (P < .0001). The mean visual acuity was 0.1 logMAR or better (20/25 or better) across the vergence range from +0.50 to -1.50 D, better than 0.2 logMAR (20/32 or better) up to the vergence of -2.00 D, and remained better than 0.3 logMAR (20/40 or better) up to the vergence of -2.50 D. The total ocular aberrations induced by EVO Viva ICL were -0.34 ± 0.09 µm of SA, 0.24 ± 0.18 µm of coma, and 0.26 ± 0.12 µm of RMS HOAs. CONCLUSIONS The outcomes support that the new ICL might be a good alternative for myopia and presbyopia correction in patients aged between 45 and 55 years. Further studies are needed to evaluate the threshold lens misalignment from which the patient´s visual quality would be affected. [J Refract Surg. 2023;39(9):589-596.].
Collapse
|
4
|
Wang Q, Fan L, Zhou Q. The best choice for low and moderate myopia patients incapable for corneal refractive surgery: implantation of a posterior chamber phakic intraocular lens. Int Ophthalmol 2023; 43:575-581. [PMID: 35984557 PMCID: PMC9971141 DOI: 10.1007/s10792-022-02459-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Accepted: 07/31/2022] [Indexed: 11/28/2022]
Abstract
PURPOSE This study aims to evaluate the early clinical outcomes of central hole phakic posterior chamber intraocular lens(ICLV4c) implantation for low and moderate myopia correction. METHODS This retrospective clinical study included 27 patients(47 eyes)who underwent ICLV4c implantation to correct myopia with spherical equivalent (SE) between - 1.75D and -6.0D. The uncorrected visual acuity (UCVA), intraocular pressure(IOP), central anterior chamber depth (ACD), vault, and endothelial cell density (ECD) were evaluated after surgery. RESULTS At one year follow-up, the postoperative UCVA of patients was higher than the preoperative CDVA and showed a stable trend. There was no significant difference in ECD (p > 0.05) one month after the surgery, the vault was 0.77 ± 0.32 mm, which decreased to 0.63 ± 0.26 mm after one year of surgery. Similarly, ACD was 3.24 ± 0.25 mm in the preoperative, which decreased significantly to 2.05 ± 0.39 mm at one month, while rose to 2.2 ± 0.39 mm at one year after surgery. There was no significant correlation between IOP and ACD and vault at one month and one year after surgery. The correlation coefficient between ACD and vault was found to be - 0.72 at one month after surgery, while the same -0.71 after one year. One patient developed visual fatigue, one with glare, and while no other complications were observed with the rest of the patients. CONCLUSION The ICL implantation is a safe, effective and stable method to correct low and moderate myopia, and may be a good alternative for patients with low and moderate myopia who cannot undergo corneal refractive surgery.
Collapse
Affiliation(s)
- Qin Wang
- Chongqing Aier Eye Hospital, Chongqing, 400020 China
| | - Lina Fan
- Chongqing Aier Eye Hospital, Chongqing, 400020 China
| | - Qizhi Zhou
- Aier Chongqing Optometry Eye hospital, No. 77, Daping Changjiang Second Road, Yuzhong, Chongqing, 400040, China.
| |
Collapse
|
5
|
Zhang H, Gong R, Zhang X, Deng Y. Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation. Int Ophthalmol 2022; 42:3625-3641. [PMID: 35731355 PMCID: PMC9587946 DOI: 10.1007/s10792-022-02355-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Accepted: 04/18/2022] [Indexed: 02/05/2023]
Abstract
PURPOSE To introduce a modified procedure of ICL implantation, to summarize the perioperative problems and their corresponding treatment after myopia correction with Implantable Collamer Lens (ICL), and to compare the difference of complications between the no-hole ICL and hole ICL. METHODS We searched all articles on ICL-related perioperative problems and their corresponding treatment in Scopus, Embase, PubMed and Web of Science databases for the last 22 years. RESULTS ICL implantation is safe, effective, stable and predictable in the correction of myopia, hyperopia and astigmatism, but can also cause a series of perioperative problems, including intraoperative and postoperative complications. CONCLUSION There are many kinds of complications related to ICL, but the common intraoperative and postoperative complications mainly include abnormality of arch height, abnormal position of ICL, loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma, cataract and night vision symptoms. Compared with ICL without central pore, the incidence of complications such as loss of corneal endothelial cells and corneal decompensation, high intraocular pressure and secondary glaucoma and cataract was relatively lower in central hole ICL, while postoperative complications such as night vision symptoms were obvious.
Collapse
Affiliation(s)
- Hao Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Rui Gong
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Xiaolan Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| | - Yingping Deng
- Department of Ophthalmology, West China Hospital, Sichuan University, No.37, Guoxue Xiang, Chengdu, 610041 Sichuan China
| |
Collapse
|