1
|
Eberhard KE, Merchant GR, Nakajima HH, Neely ST. Toward Automating Diagnosis of Middle- and Inner-ear Mechanical Pathologies With a Wideband Absorbance Regression Model. Ear Hear 2024:00003446-990000000-00283. [PMID: 38797886 DOI: 10.1097/aud.0000000000001516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
OBJECTIVES During an initial diagnostic assessment of an ear with normal otoscopic exam, it can be difficult to determine the specific pathology if there is a mechanical lesion. The audiogram can inform of a conductive hearing loss but not the underlying cause. For example, audiograms can be similar between the inner-ear condition superior canal dehiscence (SCD) and the middle-ear lesion stapes fixation (SF), despite differences in pathologies and sites of lesion. To gain mechanical information, wideband tympanometry (WBT) can be easily performed noninvasively. Absorbance , the most common WBT metric, is related to the absorbed sound energy and can provide information about specific mechanical pathologies. However, absorbance measurements are challenging to analyze and interpret. This study develops a prototype classification method to automate diagnostic estimates. Three predictive models are considered: one to identify ears with SCD versus SF, another to identify SCD versus normal, and finally, a three-way classification model to differentiate among SCD, SF, and normal ears. DESIGN Absorbance was measured in ears with SCD and SF as well as normal ears at both tympanometric peak pressure (TPP) and 0 daPa. Characteristic impedance was estimated by two methods: the conventional method (based on a constant ear-canal area) and the surge method, which estimates ear-canal area acoustically.Classification models using multivariate logistic regression predicted the probability of each condition. To quantify expected performance, the condition with the highest probability was selected as the likely diagnosis. Model features included: absorbance-only, air-bone gap (ABG)-only, and absorbance+ABG. Absorbance was transformed into principal components of absorbance to reduce the dimensionality of the data and avoid collinearity. To minimize overfitting, regularization, controlled by a parameter lambda, was introduced into the regression. Average ABG across multiple frequencies was a single feature.Model performance was optimized by adjusting the number of principal components, the magnitude of lambda, and the frequencies included in the ABG average. Finally, model performances using absorbance at TPP versus 0 daPa, and using the surge method versus constant ear-canal area were compared. To estimate model performance on a population unknown by the model, the regression model was repeatedly trained on 70% of the data and validated on the remaining 30%. Cross-validation with randomized training/validation splits was repeated 1000 times. RESULTS The model differentiating between SCD and SF based on absorbance-only feature resulted in sensitivities of 77% for SCD and 82% for SF. Combining absorbance+ABG improved sensitivities to 96% and 97%. Differentiating between SCD and normal using absorbance-only provided SCD sensitivity of 40%, which improved to 89% by absorbance+ABG. A three-way model using absorbance-only correctly classified 31% of SCD, 20% of SF and 81% of normal ears. Absorbance+ABG improved sensitivities to 82% for SCD, 97% for SF and 98% for normal. In general, classification performance was better using absorbance at TPP than at 0 daPa. CONCLUSION The combination of wideband absorbance and ABG as features for a multivariate logistic regression model can provide good diagnostic estimates for mechanical ear pathologies at initial assessment. Such diagnostic automation can enable faster workup and increase efficiency of resources.
Collapse
Affiliation(s)
- Kristine Elisabeth Eberhard
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Massachusetts Eye and Ear, Boston, MA, USA
- Copenhagen Hearing and Balance Centre, Department of Otolaryngology, Head and Neck Surgery & Audiology, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark
| | | | - Hideko Heidi Nakajima
- Department of Otolaryngology-Head and Neck Surgery, Harvard Medical School, Massachusetts Eye and Ear, Boston, MA, USA
| | | |
Collapse
|
2
|
AlMakadma HA, Reed BF, Sanford CA. An Absorbance Peak Template for Clinical Assessment of Sound Conduction in Newborn Ears. JOURNAL OF SPEECH, LANGUAGE, AND HEARING RESEARCH : JSLHR 2023; 66:5152-5168. [PMID: 37971558 DOI: 10.1044/2023_jslhr-23-00122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2023]
Abstract
PURPOSE Power absorbance measures recorded over a wide range of frequencies allow for clinical inferences about the outer/middle ears' acoustic mechanics. A frequency-dependent feature in the newborn wideband absorbance response, the prominent mid-frequency absorbance peak, has been linked to middle-ear resonance. However, current normative methods were not designed to assess subtle changes in such features. This work aims to develop and validate an absorbance peak template (APT) for assessment of absorbance peaks in newborns. Additional objectives are to compare test performance of absorbance peaks and APTs to existing normative methods, to demonstrate APT-based methods for categorization of abnormal absorbance peaks, and to describe absorbance peak test-retest variability. METHOD Peak absorbance and peak frequency were analyzed in a training data set (490 measurements in 84 newborn ears who passed transient evoked otoacoustic emissions [TEOAEs] screenings), and an APT was developed by computing normal limits on these two absorbance peak variables. Split-set analysis evaluated the reproducibility of APT, and test-retest analysis was performed. Test performance analysis, conveyed by area under the receiver operating characteristic curve (AROC) and 95% confidence intervals (CIs), compared absorbance peak variables to absorbance area indices (AAIs) in a validation data set (359 ears that passed distortion-product OAE [DPOAE] screening and 64 ears that failed). APT-based assessment paradigms for normal and abnormal ears were compared to the common absorbance normative range paradigm. RESULTS Split-set analysis demonstrated a good reproducibility of APT, and test-retest of absorbance peak variables showed that they were stable measures for clinical assessment. Test performance of peak absorbance (AROC = 0.83; 95% CI [0.77, 0.88]) was comparable to the top-performing AAI variables (AROC = 0.85; 95% CI [0.80, 0.90]). APT-based assessment categorized measurements based on their peak absorbance and peak frequency and enhanced the detection of subtle frequency changes that were missed by the normative range method. CONCLUSION Analysis of absorbance peaks guided by APT has the potential to simplify and improve assessments of sound conduction pathways in newborn ears and can be used together with or in-place of current methods for analysis of wideband absorbance data.
Collapse
Affiliation(s)
- Hammam A AlMakadma
- Department of Otolaryngology-HNS and Communicative Disorders, School of Medicine, University of Louisville, Louisville, KY
| | - Beth F Reed
- Penn State Health Milton S. Hershey Medical Center, Hershey, PA
| | - Chris A Sanford
- Department of Communication Sciences and Disorders, College of Health, Idaho State University, Pocatello
| |
Collapse
|
3
|
Golabbakhsh M, Funnell WRJ. Use of simulated data to explore the application of optical coherence tomography for classifying middle-ear pathologies. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:2790-2799. [PMID: 37916864 DOI: 10.1121/10.0022051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Accepted: 10/08/2023] [Indexed: 11/03/2023]
Abstract
Optical coherence tomography (OCT) vibrometry is a non-invasive tool for functional imaging of the middle ear. It provides spatially resolved vibrational responses and also anatomical images of the same ear. Our objective here was to explore the potential of OCT vibration measurements at the incus, as well as at the umbo, to distinguish among middle-ear disorders. Our approach was to build finite-element models of normal and pathological ears, generate large amounts of synthetic data, and then classify the simulated data into normal and pathological groups using a decision tree based on features extracted from simulated vibration magnitudes. We could distinguish between normal ears and ears with incudomallear joint (IMJ) disarticulation or stapes fixation, with the sensitivity and specificity both being 1.0; distinguish between stapes fixation and IMJ disarticulation with a sensitivity of 0.900 and a specificity of 0.889; and distinguish ears with ISJ disarticulation from normal ears with a sensitivity of 0.784 and a specificity of 0.872. Less extreme pathologies were also simulated. The results suggest that the vibration measurements within the middle ear that can be provided by OCT (e.g., at the incus) may be very valuable for diagnosis.
Collapse
Affiliation(s)
- Marzieh Golabbakhsh
- Department of BioMedical Engineering, McGill University, Montréal, Québec, Canada
| | - W Robert J Funnell
- Department of BioMedical Engineering, McGill University, Montréal, Québec, Canada
| |
Collapse
|
4
|
Zhang L, Wang J, Grais EM, Li Y, Zhao F. Three-dimensional wideband absorbance immittance findings in young adults with large vestibular aqueduct syndrome. Laryngoscope Investig Otolaryngol 2022; 8:236-244. [PMID: 36846429 PMCID: PMC9948593 DOI: 10.1002/lio2.988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 10/30/2022] [Accepted: 11/11/2022] [Indexed: 12/14/2022] Open
Abstract
Objective To investigate the effect of large vestibular aqueduct syndrome (LVAS) on middle ear sound transmission using wideband absorbance immittance (WAI). Methods WAI results from young adult LVAS patients and normal adults were compared. Results Averaged energy absorbance (EA) at ambient and peak pressure in the LVAS group showed differences to the normal group. Under ambient pressure, the average EA of the LVAS group was significantly higher than the normal group at frequencies 472-866 Hz and 6169-8000 Hz (p < .05) and lower at frequencies 1122-2520 Hz (p < .05). Under peak pressure, absorbance was increased at frequencies 515-728, 841, and 6169-8000 Hz (p < .05) and decreased at 1122-1374 Hz and 1587-2448 Hz (p < .05). An investigation into the effect of external auditory canal pressure on EA across frequencies in the pressure-frequency domain, showed that EA differed significantly in the low-frequency region of 707and 1000 Hz from 0 to 200 daPa and 500 Hz at 50 daPa (p < .05). There was also a significant difference in EA between the two groups at 8000 Hz (p < .05) in the pressure range -200-300 daPa. Conclusion WAI is a valuable tool to measure the effect of LVAS on middle ear sound transmission. LVAS has a significant effect on EA at low and mid frequencies under ambient pressure, while the frequencies affected are mainly at low frequencies when positive pressure is presented. Level of Evidence Level 3a.
Collapse
Affiliation(s)
- Lifang Zhang
- Department of Otolaryngology Head and Neck Surgery, Key Laboratory of Otolaryngology Head and Neck Surgery, Ministry of EducationBeijing Tongren Hospital, Capital Medical UniversityBeijingChina
| | - Jie Wang
- Department of Otolaryngology Head and Neck Surgery, Key Laboratory of Otolaryngology Head and Neck Surgery, Ministry of EducationBeijing Tongren Hospital, Capital Medical UniversityBeijingChina,Beijing Engineering Research Center of Audiological TechnologyBeijingChina
| | - Emad M. Grais
- Department of Automatic Control and Systems EngineeringUniversity of SheffieldSheffieldUK,Centre for Speech and Language Therapy and Hearing Science, Cardiff School of Sport and Health SciencesCardiff Metropolitan UniversityCardiffUnited Kingdom
| | - Yongxin Li
- Department of Otolaryngology Head and Neck Surgery, Key Laboratory of Otolaryngology Head and Neck Surgery, Ministry of EducationBeijing Tongren Hospital, Capital Medical UniversityBeijingChina
| | - Fei Zhao
- Centre for Speech and Language Therapy and Hearing Science, Cardiff School of Sport and Health SciencesCardiff Metropolitan UniversityCardiffUnited Kingdom
| |
Collapse
|
5
|
Pieterse H, Biagio-De Jager L, Hofmeyr LM, Vinck BHME. Wideband acoustic immittance in superior semicircular canal dehiscence. Auris Nasus Larynx 2022; 49:921-927. [PMID: 35351349 DOI: 10.1016/j.anl.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 02/28/2022] [Accepted: 03/04/2022] [Indexed: 10/18/2022]
Abstract
OBJECTIVE The apparent effect of superior semicircular canal dehiscence (SSCD) on middle ear- and cochlear impedance has led researchers to investigate the use of wideband acoustic immittance as a screening tool when SSCD is suspected. The purpose of the study was to describe the absorbance characteristics and tympanometric values of ears with confirmed SSCD measured at tympanometric peak pressure (TPP) and at ambient pressure. METHODS Wideband Acoustic Immittance was performed at ambient pressure and at TPP on ten participants (12 ears) with confirmed SSCD, as well as on an age- and gender matched control group (12 ears). Inferential statistics were used to determine whether statistical differences existed for the absorbance values at each of the averaged frequencies, the resonance frequency (RF) and tympanometric data between the SSCD and control groups. RESULTS The mean absorbance of the SSCD group reached a maximum at 890.9 Hz and a minimum at 6349.6 Hz. When testing absorbance at TPP, a statistically significant increase/peak in the absorbance values of the SSCD group (compared to those of the control group) was found from 630 to 890.9 Hz and a decrease from 4489.8 to 6349.6 Hz. Similar patterns were observed for absorbance at ambient pressure. A lower mean RF for ears with SSCD as well as an increased mean admittance magnitude (AM) value at RF was found compared to those of the control group. CONCLUSION The use of SSCD as a screening tool when SSCD is suspected was strengthened by results similar to those of previous studies. As a result of the significant difference in RF of SSCD ears compared to the RF of the control group, the potential value of measuring the RF of the middle ear to differentiate between mass-and stiffness dominated pathologies, was also illustrated.
Collapse
Affiliation(s)
- Hendriena Pieterse
- Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa
| | - Leigh Biagio-De Jager
- Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa.
| | - Louis M Hofmeyr
- Department of Speech-Language Pathology and Audiology, University of Pretoria, South Africa
| | - Bart H M E Vinck
- Department of Rehabilitation Sciences, Ghent University, Belgium
| |
Collapse
|
6
|
Preserving Wideband Tympanometry Information With Artifact Mitigation. Ear Hear 2022; 43:563-576. [PMID: 34387582 PMCID: PMC8855961 DOI: 10.1097/aud.0000000000001117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Absorbance measured using wideband tympanometry (WBT) has been shown to be sensitive to changes in middle and inner ear mechanics, with potential to diagnose various mechanical ear pathologies. However, artifacts in absorbance due to measurement noise can obscure information related to pathologies and increase intermeasurement variability. Published reports frequently present absorbance that has undergone smoothing to minimize artifact; however, smoothing changes the true absorbance and can destroy important narrow-band characteristics such as peaks and notches at different frequencies. Because these characteristics can be unique to specific pathologies, preserving them is important for diagnostic purposes. Here, we identify the cause of artifacts in absorbance and develop a technique to mitigate artifacts while preserving the underlying WBT information. DESIGN A newly developed Research Platform for the Interacoustics Titan device allowed us to study raw microphone recordings and corresponding absorbances obtained by WBT measurements. We investigated WBT measurements from normal hearing ears and ears with middle and inner ear pathologies for the presence of artifact and noise. Furthermore, it was used to develop an artifact mitigation procedure and to evaluate its effectiveness in mitigating artifacts without distorting the true WBT information. RESULTS We observed various types of noise that can plague WBT measurements and that contribute to artifacts in computed absorbances, particularly intermittent low-frequency noise. We developed an artifact mitigation procedure that incorporates a high-pass filter and a Tukey window. This artifact mitigation resolved the artifacts from low-frequency noise while preserving characteristics in absorbance in both normal hearing ears and ears with pathology. Furthermore, the artifact mitigation reduced intermeasurement variability. CONCLUSIONS Unlike smoothing algorithms used in the past, our artifact mitigation specifically removes artifacts caused by noise. It does not change frequency response characteristics, such as narrow-band peaks and notches in absorbance at different frequencies that can be important for diagnosis. Also, by reducing intermeasurement variability, the artifact mitigation can improve the test-retest reliability of these measurements.
Collapse
|
7
|
Velikoselskii A, Papatziamos G, Smeds H, Verrecchia L. Wideband tympanometry in ears with superior canal dehiscence before and after surgical correction. Int J Audiol 2021; 61:692-697. [PMID: 34420430 DOI: 10.1080/14992027.2021.1964041] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
OBJECTIVES Wideband tympanometry (WBT) has been shown to be sensitive to mechanical changes in the ear. This study investigated the effect of surgical correction of superior canal dehiscence (SCD) on WBT (i.e. absorbance and middle ear resonance frequency) compared to those on common surgical outcomes such as symptom resolution, vestibular evoked myogenic potentials (VEMP), and hearing thresholds. STUDY SAMPLE AND STUDY DESIGN Seven patients (eight ears with SCD) who underwent surgical correction of SCD underwent WBT in addition to pure-tone audiometry and VEMP assessment. RESULTS Postoperatively, all ears showed normalised/decreased absorbance at low frequencies and slightly enhanced absorbance in the middle frequency range (7/8 ears). The middle ear resonance frequency, which was initially lower than normal in most patients, increased in 6/8 operated ears, and decreased in two ears with no/partial symptom relief. In comparison, complete symptom control was observed in 6/8 operated ears, VEMP amplitudes reduced or normalised in all ears, and hearing thresholds remained stable or improved in 6/8 ears and worsened in two ears. CONCLUSIONS Surgery seems to change the response to WBT in patients with SCD. The results of WBT may represent mechanical changes induced by SCD, and should be considered when evaluating surgical outcomes.
Collapse
Affiliation(s)
- Aleksandr Velikoselskii
- Division of Ear, Nose and Throat Diseases, Audiology and Neurotology Section, Karolinska University Hospital, Stockholm, Sweden
| | - Georgios Papatziamos
- Division of Ear, Nose and Throat Diseases, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Science, Intervention and Technology, Otolaryngology Unit, Karolinska Institute, Stockholm, Sweden
| | - Henrik Smeds
- Division of Ear, Nose and Throat Diseases, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Science, Intervention and Technology, Otolaryngology Unit, Karolinska Institute, Stockholm, Sweden
| | - Luca Verrecchia
- Division of Ear, Nose and Throat Diseases, Audiology and Neurotology Section, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Science, Intervention and Technology, Otolaryngology Unit, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
8
|
Attias J, Rabinovics N, Nageris B, Hilly O. The Impact of Superior Canal Dehiscence on Power Absorbance, Otoacoustic Emissions, and Hearing in Fat Sand Rats. Otol Neurotol 2021; 42:1104-1111. [PMID: 34191786 DOI: 10.1097/mao.0000000000003147] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND Superior Semicircular Canal Dehiscence (SSCD) may lead to vestibular and auditory impairments. OBJECTIVE To study the effects of power absorbance (PA), Distortion Product Otoacoustic emissions (DPOAE), and hearing thresholds in normal ears of fat sand rats, after a bullotomy, creation and patching. METHODS SSCD was performed unilaterally in eight normal hearing animals while the contra-lateral un-operated ear was used as a control. Measures included auditory brain stem responses thresholds for air and bone conduction stimuli, DPOAEs and PA at peak pressure. RESULTS The normal PA pattern of the animals grossly resembled that of human ears. A bullotomy generated specific, large and significant (p < 0.0001) changes in PA without altering hearing thresholds. SSCD significantly decreased PA at low (p < 0.02) and increased at high frequencies (p < 0.03), but on a smaller scale than the bullotomy. SSCD, induced a mean air-bone gaps of 24.3 for clicks, and 31.2 dB for 1 kHz TB. SSCD also increased the DPOAEs levels by mean of 10.1 dB SPL (p < 0.03). Patching the dehiscence, reversed partially the PA changes, the auditory threshold shifts, and the DPOAEs levels to pre-SSCD values. CONCLUSIONS SSCD affects both incoming and emitting sounds from the ear, probably due to its effect on cochlear impedance and stiffness of the middle and inner ear. The presence of DPOAEs and ABGs indicated a "third window" disease, i.e., SSCD. Due to similar PA patterns after bullotomy and SCCD, PA alone has limited diagnostic yield for patients with SCCD.
Collapse
Affiliation(s)
- Joseph Attias
- Department of Communication Sciences & Disorders, University of Haifa, Haifa
- The Institute for Audiology & Clinical Neurophysiology, Schneider Children's Medical Center of Israel
| | - Naomi Rabinovics
- Department of Otorhinolaryngology-Head and Neck Surgery, Rabin Medical Center, Beilinson Campus, Petach Tikva
- Department of Otorhinolaryngology-Head and Neck Surgery, Samson Assuta Ashdod Hospital, Ashdod
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv to Ohad Hilly
| | - Benny Nageris
- Department of Otorhinolaryngology-Head and Neck Surgery, Samson Assuta Ashdod Hospital, Ashdod
- Department of Otorhinolaryngology-Head and Neck Surgery, Meir Medical Center, Kfar Saba, Israel
| | - Ohad Hilly
- Department of Otorhinolaryngology-Head and Neck Surgery, Rabin Medical Center, Beilinson Campus, Petach Tikva
| |
Collapse
|
9
|
Merchant GR, Neely ST. The influence of otitis media with effusion on middle-ear impedance estimated from wideband acoustic immittance measurements. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:969. [PMID: 34470321 PMCID: PMC8349246 DOI: 10.1121/10.0005822] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Revised: 07/14/2021] [Accepted: 07/14/2021] [Indexed: 06/13/2023]
Abstract
The goal of this work was to estimate the middle-ear input impedance ( Zme) from wideband acoustic immittance (WAI) measures and determine whether Zme improves the clinical utility of WAI. The data used in this study were from a previously reported set of WAI measurements in ears with otitis media with effusion [OME; Merchant, Al-Salim, Tempero, Fitzpatrick, and Neely (2021). Ear Hear., published online]. Ears with OME were grouped based on effusion volume, which was confirmed during tube surgery. Zme was estimated from the measured ear-canal impedance. An electrical-analog model of ear-canal acoustics and middle-ear mechanics was used to model the ear canal and Zme. The model results fit the measured responses well for all conditions. A regression approach was used to classify the responses of different variable types to effusion volume groups and determine the specificity and sensitivity of the binary classifications. The Zme magnitude increased with increasing effusion volume. The area under the receiver operating characteristic curve (AUC) was compared for binary decisions of the OME categories. The Zme estimate resulted in a clinically meaningful improvement in the AUC for distinguishing healthy ears from ears with OME. Overall, these results suggest that Zme estimation may provide useful information of potential clinical value to improve the diagnostic utility of WAI measurements for OME.
Collapse
Affiliation(s)
- Gabrielle R Merchant
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska, USA
| | - Stephen T Neely
- Center for Hearing Research, Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska, USA
| |
Collapse
|
10
|
Torrecilla SG, Avan P. Wideband tympanometry patterns in relation to intracranial pressure. Hear Res 2021; 408:108312. [PMID: 34298416 DOI: 10.1016/j.heares.2021.108312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Revised: 06/19/2021] [Accepted: 07/08/2021] [Indexed: 10/20/2022]
Abstract
Wideband tympanometry performs a more thorough analysis of middle-ear mechanics than the conventional single-frequency method with a 226-Hz probe tone. The present work examines the sensitivity of wideband tympanometry to the stiffness of the stapes-annular ligament system in relation to intracranial pressure (ICP) and labyrinthine fluid pressure. Here, body tilt allowed ICP to be set at different values. Sixty-eight ears of volunteers were tested sequentially in upright, supine, head-down (-30°) and upright postures. Energy absorbance of the ear was measured in these postures with a commercially available wideband-tympanometry device between 0.25 and 3 kHz, at ear-canal pressures between -600 and 300 daPa. In each posture, it was possible to find a single (posture-dependent) pressure in the ear canal at which a tympanometric peak occurred at all frequencies below about 1.1 kHz. The average across ears of tympanometric-peak pressure (TPP), close to 0 in upright posture, got increasingly positive, +19 daPa in supine and +27 daPa in head-down positions. The three-dimensional plot of energy absorbance against frequency and pressure displayed an invariant shape, merely shifting with TPP along the pressure axis. Thus, a properly adjusted ear-canal pressure neutralized the effects of ICP on the ear's energy absorbance. Comparisons to published invasive assessments of ICP in the different tested body positions led to the proposed relationship ICP ≈ 15 TPP, likely describing the transformer effect between tympanic membrane and stapes-annular ligament system at quasi-static pressures. With wideband tympanometry, the middle ear may serve as a precision scales for noninvasive ICP measurements.
Collapse
Affiliation(s)
| | - Paul Avan
- Neurosensory Biophysics Laboratory, University Clermont Auvergne, France; Institut de l'Audition, Paris, France; Centre Jean Perrin, Clermont-Ferrand, France.
| |
Collapse
|
11
|
Merchant GR, Schulz KM, Patterson JN, Fitzpatrick D, Janky KL. Effect of Cochlear Implantation on Vestibular Evoked Myogenic Potentials and Wideband Acoustic Immittance. Ear Hear 2021; 41:1111-1124. [PMID: 32032225 PMCID: PMC7392788 DOI: 10.1097/aud.0000000000000831] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The objective of this study was to determine if absent air conduction stimuli vestibular evoked myogenic potential (VEMP) responses found in ears after cochlear implantation can be the result of alterations in peripheral auditory mechanics rather than vestibular loss. Peripheral mechanical changes were investigated by comparing the response rates of air and bone conduction VEMPs as well as by measuring and evaluating wideband acoustic immittance (WAI) responses in ears with cochlear implants and normal-hearing control ears. The hypothesis was that the presence of a cochlear implant can lead to an air-bone gap, causing absent air conduction stimuli VEMP responses, but present bone conduction vibration VEMP responses (indicating normal vestibular function), with changes in WAI as compared with ears with normal hearing. Further hypotheses were that subsets of ears with cochlear implants would (a) have present VEMP responses to both stimuli, indicating normal vestibular function and either normal or near-normal WAI, or (b) have absent VEMP responses to both stimuli, regardless of WAI, due to true vestibular loss. DESIGN Twenty-seven ears with cochlear implants (age range 7 to 31) and 10 ears with normal hearing (age range 7 to 31) were included in the study. All ears completed otoscopy, audiometric testing, 226 Hz tympanometry, WAI measures (absorbance), air conduction stimuli cervical and ocular VEMP testing through insert earphones, and bone conduction vibration cervical and ocular VEMP testing with a mini-shaker. Comparisons of VEMP responses to air and bone conduction stimuli, as well as absorbance responses between ears with normal hearing and ears with cochlear implants, were completed. RESULTS All ears with normal hearing demonstrated 100% present VEMP response rates for both stimuli. Ears with cochlear implants had higher response rates to bone conduction vibration compared with air conduction stimuli for both cervical and ocular VEMPs; however, this was only significant for ocular VEMPs. Ears with cochlear implants demonstrated reduced low-frequency absorbance (500 to 1200 Hz) as compared with ears with normal hearing. To further analyze absorbance, ears with cochlear implants were placed into subgroups based on their cervical and ocular VEMP response patterns. These groups were (1) present air conduction stimuli response, present bone conduction vibration response, (2) absent air conduction stimuli response, present bone conduction vibration response, and (3) absent air conduction stimuli response, absent bone conduction vibration response. For both cervical and ocular VEMPs, the group with absent air conduction stimuli responses and present bone conduction vibration responses demonstrated the largest decrease in low-frequency absorbance as compared with the ears with normal hearing. CONCLUSIONS Bone conduction VEMP response rates were increased compared with air-conduction VEMP response rates in ears with cochlear implants. Ears with cochlear implants also demonstrate changes in low-frequency absorbance consistent with a stiffer system. This effect was largest for ears that had absent air conduction but present bone conduction VEMPs. These findings suggest that this group, in particular, has a mechanical change that could lead to an air-bone gap, thus, abolishing the air conduction VEMP response due to an alteration in mechanics and not a true vestibular loss. Clinical considerations include using bone conduction vibration VEMPs and WAI for preoperative and postoperative testing in patients undergoing cochlear implantation.
Collapse
Affiliation(s)
| | - Kyli M. Schulz
- Boys Town National Research Hospital, Omaha, NE 68131
- The University of Texas at Austin, TX 78712
| | | | | | | |
Collapse
|
12
|
Song Cheng Y, Raufer S, Guan X, Halpin CF, Lee DJ, Nakajima HH. Superior Canal Dehiscence Similarly Affects Cochlear Pressures in Temporal Bones and Audiograms in Patients. Ear Hear 2021; 41:804-810. [PMID: 31688316 PMCID: PMC7190445 DOI: 10.1097/aud.0000000000000799] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVES The diagnosis of superior canal dehiscence (SCD) is challenging and audiograms play an important role in raising clinical suspicion of SCD. The typical audiometric finding in SCD is the combination of increased air conduction (AC) thresholds and decreased bone conduction thresholds at low frequencies. However, this pattern is not always apparent in audiograms of patients with SCD, and some have hearing thresholds that are within the normal reference range despite subjective reports of hearing impairment. In this study, we used a human temporal bone model to measure the differential pressure across the cochlear partition (PDiff) before and after introduction of an SCD. PDiff estimates the cochlear input drive and provides a mechanical audiogram of the temporal bone. We measured PDiff across a wider frequency range than in previous studies and investigated whether the changes in PDiff in the temporal bone model and changes of audiometric thresholds in patients with SCD were similar, as both are thought to reflect the same physical phenomenon. DESIGN We measured PDiff across the cochlear partition in fresh human cadaveric temporal bones before and after creating an SCD. Measurements were made for a wide frequency range (20 Hz to 10 kHz), which extends down to lower frequencies than in previous studies and audiograms. PDiff = PSV- PST is calculated from pressures measured simultaneously at the base of the cochlea in scala vestibuli (PSV) and scala tympani (PST) during sound stimulation. The change in PDiff after an SCD is created quantifies the effect of SCD on hearing. We further included an important experimental control-by patching the SCD, to confirm that PDiff was reversed back to the initial state. To provide a comparison of temporal bone data to clinical data, we analyzed AC audiograms (250 Hz to 8kHz) of patients with symptomatic unilateral SCD (radiographically confirmed). To achieve this, we used the unaffected ear to estimate the baseline hearing function for each patient, and determined the influence of SCD by referencing AC hearing thresholds of the SCD-affected ear with the unaffected contralateral ear. RESULTS PDiff measured in temporal bones (n = 6) and AC thresholds in patients (n = 53) exhibited a similar pattern of SCD-related change. With decreasing frequency, SCD caused a progressive decrease in PDiff at low frequencies for all temporal bones and a progressive increase in AC thresholds at low frequencies. SCD decreases the cochlear input drive by approximately 6 dB per octave at frequencies below ~1 kHz for both PDiff and AC thresholds. Individual data varied in frequency and magnitude of this SCD effect, where some temporal-bone ears had noticeable effects only below 250 Hz. CONCLUSIONS We found that with decrease in frequency the progressive decrease in low-frequency PDiff in our temporal bone experiments mirrors the progressive elevation in AC hearing thresholds observed in patients. This hypothesis remains to be tested in the clinical setting, but our findings suggest that that measuring AC thresholds at frequencies below 250 Hz would detect a larger change, thus improving audiograms as a diagnostic tool for SCD.
Collapse
Affiliation(s)
- Y. Song Cheng
- New York University Medical Center, New York, NY, 10016, USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear, 243 Charles St, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02114, USA
| | - Stefan Raufer
- Speech and Hearing Bioscience and Technology Program, Harvard Medical School, 260 Longwood Ave., Boston, MA, 02115, USA
| | - Xiying Guan
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear, 243 Charles St, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02114, USA
| | | | - Daniel J. Lee
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear, 243 Charles St, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02114, USA
| | - Hideko Heidi Nakajima
- Speech and Hearing Bioscience and Technology Program, Harvard Medical School, 260 Longwood Ave., Boston, MA, 02115, USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear, 243 Charles St, Boston, MA, 02114, USA
- Department of Otolaryngology, Harvard Medical School, Boston, MA, 02114, USA
| |
Collapse
|
13
|
Ward BK, van de Berg R, van Rompaey V, Bisdorff A, Hullar TE, Welgampola MS, Carey JP. Superior semicircular canal dehiscence syndrome: Diagnostic criteria consensus document of the committee for the classification of vestibular disorders of the Bárány Society. J Vestib Res 2021; 31:131-141. [PMID: 33522990 PMCID: PMC9249274 DOI: 10.3233/ves-200004] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This paper describes the diagnostic criteria for superior semicircular canal dehiscence syndrome (SCDS) as put forth by the classification committee of the Bárány Society. In addition to the presence of a dehiscence of the superior semicircular canal on high resolution imaging, patients diagnosed with SCDS must also have symptoms and physiological tests that are both consistent with the pathophysiology of a ‘third mobile window’ syndrome and not better accounted for by another vestibular disease or disorder. The diagnosis of SCDS therefore requires a combination of A) at least one symptom consistent with SCDS and attributable to ‘third mobile window’ pathophysiology including 1) hyperacusis to bone conducted sound, 2) sound-induced vertigo and/or oscillopsia time-locked to the stimulus, 3) pressure-induced vertigo and/or oscillopsia time-locked to the stimulus, or 4) pulsatile tinnitus; B) at least 1 physiologic test or sign indicating that a ‘third mobile window’ is transmitting pressure including 1) eye movements in the plane of the affected superior semicircular canal when sound or pressure is applied to the affected ear, 2) low-frequency negative bone conduction thresholds on pure tone audiometry, or 3) enhanced vestibular-evoked myogenic potential (VEMP) responses (low cervical VEMP thresholds or elevated ocular VEMP amplitudes); and C) high resolution computed tomography (CT) scan with multiplanar reconstruction in the plane of the superior semicircular canal consistent with a dehiscence. Thus, patients who meet at least one criterion in each of the three major diagnostic categories (symptoms, physiologic tests, and imaging) are considered to have SCDS.
Collapse
Affiliation(s)
- Bryan K Ward
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University, Baltimore, USA
| | - Raymond van de Berg
- Department of Otorhinolaryngology and Head & Neck Surgery, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Vincent van Rompaey
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Belgium
| | - Alexandre Bisdorff
- Clinique du Vertige, Centre Hospitalier Emile Mayrisch, Esch-sur-Alzette, Luxembourg
| | - Timothy E Hullar
- VA Portland National Center for Rehabilitative Auditory Research and Department of Otolaryngology-Head & Neck Surgery, Oregon Health & Science University, Portland, USA
| | - Miriam S Welgampola
- Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Central Clinical School, University of Sydney, Australia
| | - John P Carey
- Department of Otolaryngology-Head & Neck Surgery, Johns Hopkins University, Baltimore, USA
| |
Collapse
|
14
|
Improving the Differential Diagnosis of Otitis Media With Effusion Using Wideband Acoustic Immittance. Ear Hear 2021; 42:1183-1194. [PMID: 33928915 DOI: 10.1097/aud.0000000000001037] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The objective of this work is to determine whether there is a systematic effect of middle ear effusion volume on wideband acoustic immittance in children with surgically confirmed otitis media with effusion. DESIGN Wideband acoustic immittance was measured in 49 ears from children (9 months to 11 years) who had a diagnosis of otitis media with effusion and compared to 14 ears from children (10 months to 10 years) without a recent history of otitis media. For children with otitis media with effusion, wideband acoustic immittance testing took place in the child's preoperative waiting room before surgical placement of tympanostomy tubes. Testing was completed in a pressurized condition (wideband tympanometry) for all ears as well as in an ambient condition in a subset of ears. Intraoperative findings regarding effusion volume were reported by the surgeons immediately before tube placement and confirmed following myringotomy. This classified the volume of effusion as compared to middle ear volume categorically as either full, partial, or clear of effusion. The type of wideband acoustic immittance explored in this work was absorbance. Absorbance responses were grouped based on effusion volume into one of four groups: full effusions, partial effusions, ears clear of effusion at the time of surgery, and normal control ears. Standard tympanometry was also completed on all ears. RESULTS Absorbance is systematically reduced as the volume of the middle ear effusion increases. This reduction is present at most frequencies but is greatest in the frequency range from 1 to 5 kHz. A multivariate logistic regression approach was utilized to classify ears based on effusion volume. The regression approach classified ears as effusion present (full and partial ears) or absent (clear ears and normal control ears) with 100% accuracy, ears with effusion present as either partial or full with 100% accuracy, and ears without effusion as either normal control ears or ears clear of effusion with 75% accuracy. Regression performance was also explored when the dataset was split into a training set (70% of the data) and a validation test set (30% of the data) to simulate how this approach would perform on unseen data in a clinical setting. Accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve are reported. Overall, this approach demonstrates high sensitivity and specificity for classifying ears as effusion being present or absent and as present effusions being full or partial with areas under the curve ranging from 1 to 0.944. Despite the lack of effusion present in both clear ears and normal control ears, this approach was able to distinguish between these ears, but with a more moderate sensitivity and specificity. No systematic effect of effusion volume was found on standard tympanometry. CONCLUSIONS Wideband acoustic immittance, and more specifically, absorbance, is a strong and sensitive indicator of the volume of a middle ear effusion in children with otitis media with effusion.
Collapse
|
15
|
Eberhard KE, Chari DA, Nakajima HH, Klokker M, Cayé-Thomasen P, Lee DJ. Current Trends, Controversies, and Future Directions in the Evaluation and Management of Superior Canal Dehiscence Syndrome. Front Neurol 2021; 12:638574. [PMID: 33889125 PMCID: PMC8055857 DOI: 10.3389/fneur.2021.638574] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2020] [Accepted: 02/08/2021] [Indexed: 01/14/2023] Open
Abstract
Patients with superior canal dehiscence syndrome (SCDS) can present with a range of auditory and/or vestibular signs and symptoms that are associated with a bony defect of the superior semicircular canal (SSC). Over the past two decades, advances in diagnostic techniques have raised the awareness of SCDS and treatment approaches have been refined to improve patient outcomes. However, a number of challenges remain. First, there is currently no standardized clinical testing algorithm for quantifying the effects of superior canal dehiscence (SCD). SCDS mimics a number of common otologic disorders and established metrics such as supranormal bone conduction thresholds and vestibular evoked myogenic potential (VEMP) measurements; although useful in certain cases, have diagnostic limitations. Second, while high-resolution computed tomography (CT) is the gold standard for the detection of SCD, a bony defect does not always result in signs and symptoms. Third, even when SCD repair is indicated, there is a lack of consensus about nomenclature to describe the SCD, ideal surgical approach, specific repair techniques, and type of materials used. Finally, there is no established algorithm in evaluation of SCDS patients who fail primary repair and may be candidates for revision surgery. Herein, we will discuss both contemporary and emerging diagnostic approaches for patients with SCDS and highlight challenges and controversies in the management of this unique patient cohort.
Collapse
Affiliation(s)
- Kristine Elisabeth Eberhard
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
- Copenhagen Hearing and Balance Centre, Department of Otorhinolaryngology, Head and Neck Surgery & Audiology, Copenhagen University Hospital – Rigshospitalet, Copenhagen, Denmark
| | - Divya A. Chari
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
| | - Hideko Heidi Nakajima
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
| | - Mads Klokker
- Copenhagen Hearing and Balance Centre, Department of Otorhinolaryngology, Head and Neck Surgery & Audiology, Copenhagen University Hospital – Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Per Cayé-Thomasen
- Copenhagen Hearing and Balance Centre, Department of Otorhinolaryngology, Head and Neck Surgery & Audiology, Copenhagen University Hospital – Rigshospitalet, Copenhagen, Denmark
- Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Daniel J. Lee
- Department of Otolaryngology, Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, United States
| |
Collapse
|
16
|
Abstract
OBJECTIVE Determine if changes in middle ear absorbance measured with wide-band tympanometry (WBT) occur following hearing-preservation cochlear implantation (CI). Such measures may provide insight into the mechanisms of acoustic hearing loss postimplantation. STUDY DESIGN Clinical capsule report. SETTING Tertiary academic referral center. DESIGN WBT absorbance was measured bilaterally during pre- and postoperative clinical office visits in five unilaterally-implanted cochlear implant recipients. Pre- and postoperative WBT measures were compared within each subject in the implanted and contralateral, unimplanted ears. RESULTS In general, WBT absorbance measurements show a broad spectral pattern including two or three distinct peaks measured over a frequency range of 226 to 8000 Hz. Grand average and linear mixed model comparisons between the pre- and postoperative WBT patterns show significantly reduced (p < 0.05) low-frequency absorbance in the implanted ears in the frequency region over 0.6 to 1.1 kHz, but not in the unimplanted ears. The maximum effect occurred at 1 kHz with absorbance decreasing from ∼0.8 to ∼0.5 after implantation. The limited data are consistent with expected relationships between WBT absorbance and air- and bone-conduction thresholds, assuming an increased air-bone gap reflects conductive hearing loss. CONCLUSION Cochlear implantation can result in reduction of low-frequency acoustic absorbance as measured by WBT. WBT may be a useful and sensitive tool for monitoring the mechanical status of the middle and inner ears following cochlear implantation.
Collapse
|
17
|
Merchant GR, Siegel JH, Neely ST, Rosowski JJ, Nakajima HH. Effect of Middle-Ear Pathology on High-Frequency Ear Canal Reflectance Measurements in the Frequency and Time Domains. J Assoc Res Otolaryngol 2019; 20:529-552. [PMID: 31673928 PMCID: PMC6889121 DOI: 10.1007/s10162-019-00735-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 08/20/2019] [Indexed: 10/25/2022] Open
Abstract
The effects of middle-ear pathology on wideband acoustic immittance and reflectance at frequencies above 6-8 kHz have not been documented, nor has the effect of such pathologies on the time-domain reflectance. We describe an approach that utilizes sound frequencies as high as 20 kHz and quantifies reflectance in both the frequency and time domains. Experiments were performed with fresh normal human temporal bones before and after simulating various middle-ear pathologies, including malleus fixation, stapes fixation, and disarticulation. In addition to experimental data, computational modeling was used to obtain fitted parameter values of middle-ear elements that vary systematically due to the simulated pathologies and thus may have diagnostic implications. Our results demonstrate that the time-domain reflectance, which requires acoustic measurements at high frequencies, varies with middle-ear condition. Furthermore, the extended bandwidth frequency-domain reflectance data was used to estimate parameters in a simple model of the ear canal and middle ear that separates three major conductive pathologies from each other and from the normal state.
Collapse
Affiliation(s)
- Gabrielle R. Merchant
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Boys Town National Research Hospital, Omaha, NE USA
| | | | | | - John J. Rosowski
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Department of Otology and Laryngology, Harvard Medical School, Boston, MA USA
| | - Hideko H. Nakajima
- Speech and Hearing Bioscience and Technology, Harvard Division of Medical Sciences (formerly the Harvard-MIT Division of Health Sciences and Technology), Cambridge, MA USA
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA USA
- Department of Otology and Laryngology, Harvard Medical School, Boston, MA USA
| |
Collapse
|
18
|
Nørgaard KR, Charaziak KK, Shera CA. On the calculation of reflectance in non-uniform ear canals. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1464. [PMID: 31472574 PMCID: PMC6713557 DOI: 10.1121/1.5124000] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 08/02/2019] [Accepted: 08/08/2019] [Indexed: 05/29/2023]
Abstract
Ear-canal reflectance is useful for quantifying the conductive status of the middle ear because it can be measured non-invasively at a distance from the tympanic membrane. Deriving the ear-canal reflectance requires decomposing the total acoustic pressure into its forward- and reverse-propagating components. This decomposition is conveniently achieved using formulas that involve the input and characteristic impedances of the ear canal. The characteristic impedance is defined as the ratio of sound pressure to volume flow of a propagating wave and, for uniform waveguides, the plane-wave characteristic impedance is a real-valued constant. However, in non-uniform waveguides, the characteristic impedances are complex-valued quantities, depend on the direction of propagation, and more accurately characterize a propagating wave in a non-uniform ear canal. In this paper, relevant properties of the plane-wave and spherical-wave characteristic impedances are reviewed. In addition, the utility of the plane-wave and spherical-wave reflectances in representing the reflection occurring due to the middle ear, calibrating stimulus levels, and characterizing the emitted pressure in simulated non-uniform ear canals is investigated and compared.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Karolina K Charaziak
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| |
Collapse
|
19
|
Nørgaard KR, Charaziak KK, Shera CA. A comparison of ear-canal-reflectance measurement methods in an ear simulator. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 146:1350. [PMID: 31472530 PMCID: PMC6707811 DOI: 10.1121/1.5123379] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Revised: 08/02/2019] [Accepted: 08/03/2019] [Indexed: 05/30/2023]
Abstract
Ear-canal reflectance has been researched extensively for diagnosing conductive hearing disorders and compensating for the ear-canal acoustics in non-invasive measurements of the auditory system. Little emphasis, however, has been placed on assessing measurement accuracy and variability. In this paper, a number of ear-canal-reflectance measurement methods reported in the literature are utilized and compared. Measurement variation seems to arise chiefly from three factors: the residual ear-canal length, the ear-probe insertion angle, and the measurement frequency bandwidth. Calculation of the ear-canal reflectance from the measured ear-canal impedance requires estimating the ear-canal characteristic impedance in situ. The variability in ear-canal estimated characteristic impedance and reflectance due to these principal factors is assessed in an idealized controlled setup using a uniform occluded-ear simulator. In addition, the influence of this measurement variability on reflectance-based methods for calibrating stimulus levels is evaluated and, by operating the condenser microphone of the occluded-ear simulator as an electro-static speaker, the variability in estimating the emitted pressure from the ear is determined. The various measurement methods differ widely in their robustness to variations in the three principal factors influencing the accuracy and variability of ear-canal reflectance.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Karolina K Charaziak
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| | - Christopher A Shera
- Caruso Department of Otolaryngology, University of Southern California, 1640 Marengo Street, Los Angeles, California 90033, USA
| |
Collapse
|
20
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. Compensating for oblique ear-probe insertions in ear-canal reflectance measurements. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3499. [PMID: 31255109 DOI: 10.1121/1.5111340] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 05/22/2019] [Indexed: 06/09/2023]
Abstract
Measurements of the ear-canal reflectance using an ear probe require estimating the characteristic impedance of the ear canal in situ. However, an oblique insertion of the ear probe into a uniform waveguide prevents accurately estimating its characteristic impedance using existing time-domain methods. This is caused by the non-uniformity immediately in front of the ear probe when inserted at an oblique angle, resembling a short horn loading, and introduces errors into the ear-canal reflectance. This paper gives an overview of the influence of oblique ear-probe insertions and shows how they can be detected and quantified by estimating the characteristic impedance using multiple truncation frequencies, i.e., limiting the utilized frequency range. Additionally, a method is proposed to compensate for the effects on reflectance of an oblique ear-probe insertion into a uniform waveguide. The incident impedance of the horn loading is estimated, i.e., were the uniform waveguide anechoic, which replaces the characteristic impedance when calculating reflectance. The method can compensate for an oblique ear-probe insertion into a uniform occluded-ear simulator and decrease the dependency of reflectance on insertion depth in an ear canal. However, more research is required to further assess the method in ear canals.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
21
|
Demir E, Afacan NN, Celiker M, Celiker FB, İnecikli MF, Terzi S, Dursun E. Can Wideband Tympanometry Be Used as a Screening Test for Superior Semicircular Canal Dehiscence? Clin Exp Otorhinolaryngol 2018; 12:249-254. [PMID: 30458602 PMCID: PMC6635713 DOI: 10.21053/ceo.2018.01137] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 10/01/2018] [Indexed: 11/22/2022] Open
Abstract
OBJECTIVES We explored whether wideband tympanometry (WBT) could be used as a screening test for superior semicircular canal dehiscence (SSCD), and obtained new WBT data (given that the test is not yet in common clinical use) on patients with SSCD. METHODS We compared the WBT data of patients clinically and radiologically diagnosed with SSCD in our hospital between 2013 and 2018 to those of healthy volunteers. We compared the resonance frequency (RF), maximum absorbance frequency (MAF), and maximum absorbance ratio (MAR). The t-test was used for statistical analysis with the significance level set to P<0.05. In addition, we used receiver operating characteristic analysis to derive cutoff values for SSCD diagnosis in terms of sensitivity and specificity. RESULTS Seventeen patients (four with bilateral and 13 with unilateral disease; 17 ears) diagnosed with SSCD and 27 healthy volunteers (47 ears) were included. The mean RFs of the SSCD patients and healthy subjects were 548.7 Hz (range, 243 to 853 Hz) and 935.1 Hz (range, 239 to 1,875 Hz), respectively (P<0.001). The mean MARs of the SSCD patients and healthy subjects were 89.4% (range, 62% to 100%) and 82.4% (range, 63% to 99%), respectively (P=0.005). The mean MAFs of the SSCD patients and healthy subjects were 1,706.3 Hz (range, 613 to 3,816 Hz) and 2,668 Hz (range, 876 to 4,387 Hz), respectively (P<0.001). In terms of SSCD diagnosis, a MAR above 86% afforded 81% sensitivity and 77% specificity; an RF below 728 Hz, 86% sensitivity and 81% specificity; and an MAF below 1,835 Hz, 79% sensitivity and 67% specificity. CONCLUSION WBT may be a useful clinical screening test for SSCD. The RF and MAF were lower, and the MAR higher, in SSCD patients than in normal controls.
Collapse
Affiliation(s)
- Emine Demir
- Department of Otorhinolaryngology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Nazife Nur Afacan
- Department of Otorhinolaryngology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Metin Celiker
- Department of Otorhinolaryngology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Fatma Beyazal Celiker
- Department of Radiology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Mehmet Fatih İnecikli
- Department of Radiology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Suat Terzi
- Department of Otorhinolaryngology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| | - Engin Dursun
- Department of Otorhinolaryngology, Recep Tayyip Erdogan University Faculty of Medicine, Rize, Turkey
| |
Collapse
|
22
|
Nørgaard KR, Neely ST, Rasetshwane DM. Quantifying undesired parallel components in Thévenin-equivalent acoustic source parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 143:1491. [PMID: 29604709 PMCID: PMC5856597 DOI: 10.1121/1.5026796] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The calibration of an ear probe to determine its Thévenin-equivalent acoustic source parameters facilitates the measurement of ear-canal impedance and reflectance. Existing calibration error metrics, used to evaluate the quality of a calibration, are unable to reveal undesired parallel components in the source parameters. Such parallel components can result from, e.g., a leak in the ear tip or improperly accounting for evanescent modes, and introduce errors into subsequent measurements of impedance and reflectance. This paper proposes a set of additional error metrics that are capable of detecting such parallel components by examining the causality of the source admittance in the frequency domain and estimating the source pressure in the time domain. The proposed and existing error metrics are applied to four different calibrations using two existing calibration methods, representing typical use cases and introducing deliberate parallel components. The results demonstrate the capability of the proposed error metrics in identifying various undesired components in the source parameters that might otherwise go undetected.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Stephen T Neely
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| | - Daniel M Rasetshwane
- Boys Town National Research Hospital, 555 North 30th Street, Omaha, Nebraska 68131, USA
| |
Collapse
|
23
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. Compensating for evanescent modes and estimating characteristic impedance in waveguide acoustic impedance measurements. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:3497. [PMID: 29289093 DOI: 10.1121/1.5016808] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The ear-canal acoustic impedance and reflectance are useful for assessing conductive hearing disorders and calibrating stimulus levels in situ. However, such probe-based measurements are affected by errors due to the presence of evanescent modes and incorrect estimates or assumptions regarding characteristic impedance. This paper proposes a method to compensate for evanescent modes in measurements of acoustic impedance, reflectance, and sound pressure in waveguides, as well as estimating the characteristic impedance immediately in front of the probe. This is achieved by adjusting the characteristic impedance and subtracting an acoustic inertance from the measured impedance such that the non-causality in the reflectance is minimized in the frequency domain using the Hilbert transform. The method is thus capable of estimating plane-wave quantities of the sought-for parameters by supplying only an arbitrary initial value for the characteristic impedance. From a comparison with a simulated waveguide, it is shown that this method can accurately estimate these quantities in a waveguide that is uniform at the position of the probe. Finally, it is demonstrated how evanescent modes, characteristic impedance, and the proposed methodology can affect the measured acoustic impedance and reflectance of an occluded-ear simulator.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
24
|
Nørgaard KR, Fernandez-Grande E, Laugesen S. Incorporating evanescent modes and flow losses into reference impedances in acoustic Thévenin calibration. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2017; 142:3013. [PMID: 29195468 DOI: 10.1121/1.5010891] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This paper proposes an alternative approach to acoustic Thévenin calibration of an ear probe. An existing methodology derives the Thévenin-equivalent source parameters from the measured probe pressures in a number of short waveguides by solving an overdetermined system of equations. This existing methodology is affected by errors caused by evanescent modes when the waveguide model lengths are estimated. These errors introduce a parallel acoustic compliance into the source parameters. The proposed methodology takes into account evanescent modes and flow losses in the transition between the probe tube and waveguides during calibration. This is achieved by positioning the probe tube, without an ear tip, flush with the input plane in waveguides of well-defined dimensions and utilizing the physical rather than estimated lengths to calculate the analytical waveguide models. Terms that model evanescent modes and flow losses are added to the plane-wave impedance and adjusted to minimize the calibration error. It is shown that this method can reduce the calibration error across a wide frequency range and remove the parallel compliance from the source parameters. This approach leads to an independence of the source parameters on the calibration waveguide radius, though subsequent impedance measurements are still affected by evanescent modes.
Collapse
Affiliation(s)
- Kren Rahbek Nørgaard
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Efren Fernandez-Grande
- Acoustic Technology, Department of Electrical Engineering, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| | - Søren Laugesen
- Interacoustics Research Unit, Technical University of Denmark, Ørsteds Plads, Building 352, Kongens Lyngby, DK-2800, Denmark
| |
Collapse
|
25
|
Controlled exploration of the effects of conductive hearing loss on wideband acoustic immittance in human cadaveric preparations. Hear Res 2016; 341:19-30. [PMID: 27496538 DOI: 10.1016/j.heares.2016.07.018] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 07/26/2016] [Accepted: 07/30/2016] [Indexed: 11/24/2022]
Abstract
Current clinical practice cannot distinguish, with any degree of certainty, the multiple pathologies that produce conductive hearing loss in patients with an intact tympanic membrane and a well-aerated middle ear without exploratory surgery. The lack of an effective non-surgical diagnostic procedure leads to unnecessary surgery and limits the accuracy of information available during pre-surgical consultations with the patient. A non-invasive measurement to determine the pathology responsible for a conductive hearing loss prior to surgery would be of great value. This work investigates the utility of wideband acoustic immittance (WAI), a non-invasive measure of middle-ear mobility, in the differential diagnosis of pathologies responsible for conductive hearing loss. We focus on determining whether power reflectance (PR), a derivative of WAI, is a possible solution to this problem. PR is a measure of the fraction of sound power reflected from the middle ear when a sound stimulus is presented to the ear canal. PR and other metrics of middle-ear performance (such as ossicular motion via laser Doppler vibrometry) were measured in well-controlled human temporal bone preparations with simulated pathologies. We report measurements before and after simulation of stapes fixation (n = 8), malleus fixation (n = 10), ossicular disarticulation (n = 10), and superior canal dehiscence (n = 8). Our results are consistent with the small set of previously published reflectance measurements made in temporal bones and patients. In this present study, these temporal bone experiments with different middle- and inner-ear pathologies were compared to the initial normal state by analyzing both WAI and ossicular motion, demonstrating that WAI can be a valuable tool in the diagnosis of conductive hearing loss.
Collapse
|
26
|
Rasetshwane DM, Neely ST. Reflectance measurement validation using acoustic horns. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2015; 138:2246-55. [PMID: 26520306 PMCID: PMC4617734 DOI: 10.1121/1.4930948] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Variability in wideband acoustic reflectance (and absorbance) measurements adversely affects the clinical utility of reflectance for diagnosis of middle-ear disorders. A reflectance standard would encourage consistency across different measurement systems and help identify calibration related issues. Theoretical equations exist for the reflectance of finite-length exponential, conical, and parabolic acoustic horns. Reflectance measurements were repeatedly made in each of these three horn shapes and the results were compared to the corresponding theoretical reflectance. A method is described of adjusting acoustic impedance measurements to compensate for spreading of the wave front that propagates from the small diameter sound port of the probe to the larger diameter of the acoustic cavity. Agreement between measured and theoretical reflectance was less than 1 dB at most frequencies in the range from 0.2 to 10 kHz. Pearson correlation coefficients were greater than 0.95 between measured and theoretical time-domain reflectance within the flare region of the horns. The agreement suggests that the distributed reflectance of acoustic horns may be useful for validating reflectance measurements made in human ear canals; however, refinements to reflectance measurement methods may still be needed.
Collapse
Affiliation(s)
| | - Stephen T Neely
- Boys Town National Research Hospital, Omaha, Nebraska 68131, USA
| |
Collapse
|