Gerbert M, Ernst A, Seidl R, Decker L, Scholz S, Lauer G, Mittmann P. Preservation of Residual Hearing: Long-Term Results With a Mid-Scala Electrode. J Otolaryngol Head Neck Surg 2024; 53:19160216241250351. [PMID: 38888946 PMCID: PMC11155315 DOI: 10.1177/19160216241250351] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 03/30/2024] [Indexed: 06/20/2024] Open
Abstract
OBJECTIVE The long-term preservation of residual hearing after cochlear implantation has become a major goal over the past few years. The aim of the present study was to evaluate residual hearing in the long-term follow-up using mid-scala electrodes. METHODS In this retrospective, single-center study, we collected data from 27 patients who were implanted between 2014 and 2015 with residual hearing in the low-frequency range using a mid-scala electrode. Measurements of the hearing thresholds were carried out directly postoperatively (day 1 after surgery) and in the long-term follow-up 43.7 ± 6.9 months. The calculation of the extent of audiological hearing preservation was determined using the HEARRING group formula by Skarsynski. RESULTS Postoperative preservation of residual hearing was achieved in 69.2% of the cases in the low-frequency range between 250 Hz and 1 kHz, of which 89.5% of the patients had frequencies that suggested using electroacoustic stimulation (EAS). In the long-term follow-up, 30.8% of the patients showed residual hearing; however, 57.1% had apparently benefited from EAS. CONCLUSION Preservation of residual hearing is feasible in the long term using mid-scala electrodes. Postoperatively, there is over the half of patients who benefit from an EAS strategy. The long-term follow-up shows a certain decrease in residual hearing. However, these results are comparable to studies relating to other types of electrodes. Further research should be conducted in future to better evaluate hearing loss in long-term follow-up, compared to direct postoperative audiological results.
Collapse
Affiliation(s)
- Martin Gerbert
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Arne Ernst
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Rainer Seidl
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Lars Decker
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Sandra Scholz
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Gina Lauer
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| | - Philipp Mittmann
- Department of Otolaryngology, Head and Neck Surgery, Unfallkrankenhaus Berlin, Berlin, Germany
| |
Collapse
|
2
|
Lambriks L, van Hoof M, Debruyne J, Janssen M, Hof J, Hellingman K, Devocht E, George E. Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and behavioral stimulation levels. Front Neurol 2023; 14:1093265. [PMID: 36846130 PMCID: PMC9948626 DOI: 10.3389/fneur.2023.1093265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Estimating differences in neural health across different sites within the individual cochlea potentially enables clinical applications for subjects with a cochlear implant. The electrically evoked compound action potential (ECAP) is a measure of neural excitability that possibly provides an indication of a neural condition. There are many factors, however, that affect this measure and increase the uncertainty of its interpretation. To better characterize the ECAP response, its relationship with electrode positioning, impedances, and behavioral stimulation levels was explored. Methods A total of 14 adult subjects implanted with an Advanced Bionics cochlear electrode array were prospectively followed up from surgery to 6 months postoperative. Insertion depth, distance to the modiolus, and distance to the medial wall were assessed for each electrode by postoperative CT analysis. ECAPs were measured intraoperatively and at three visits postoperatively on all 16 electrodes using the NRI feature of clinical programming software and characterized using multiple parameters. Impedances and behavioral stimulation levels were measured at every fitting session. Results Patterns in ECAPs and impedances were consistent over time, but high variability existed among subjects and between different positions in the cochlea. Electrodes located closer to the apex of the cochlea and closer to the modiolus generally showed higher neural excitation and higher impedances. Maximum loudness comfort levels were correlated strongly with the level of current needed to elicit a response of 100 μV ECAP. Conclusion Multiple factors contribute to the ECAP response in subjects with a cochlear implant. Further research might address whether the ECAP parameters used in this study will benefit clinical electrode fitting or the assessment of auditory neuron integrity.
Collapse
Affiliation(s)
- Lars Lambriks
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,*Correspondence: Lars Lambriks ✉
| | - Marc van Hoof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Joke Debruyne
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Miranda Janssen
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | - Janny Hof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Katja Hellingman
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Elke Devocht
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Erwin George
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
3
|
Functional Outcomes and Quality of Life after Cochlear Implantation in Patients with Long-Term Deafness. J Clin Med 2022; 11:jcm11175156. [PMID: 36079089 PMCID: PMC9457208 DOI: 10.3390/jcm11175156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 11/17/2022] Open
Abstract
Background: Hearing-related quality of life (QoL) after cochlear implantation (CI) is as important as audiological performance. We evaluated the functional results and QoL after CI in a heterogeneous patient cohort with emphasis on patients with long-term deafness (>10 years). Methods: Twenty-eight patients (n = 32 implanted ears, within n = 12 long-term deaf ears) implanted with a mid-scala electrode array were included in this retrospective mono-centric cohort study. Speech intelligibility for monosyllables (SIM), speech reception thresholds (SRT50) and QoL with Nijmegen Cochlear Implant Questionnaire (NCIQ) were registered. Correlation of SIM and QoL was analyzed. Results: SIM and SRT50 improved significantly 12 months postoperatively up to 54.8 ± 29.1% and 49.3 ± 9.6 dB SPL, respectively. SIM progressively improved up to 1 year, but some early-deafened, late implanted patients developed speech understanding several years after implantation. The global and all subdomain QoL scores increased significantly up to 12 months postoperatively and we found a correlation of SIM and global QoL score at 12 months postoperatively. Several patients of the “poor performer” (SIM < 40%) group reported high improvement of hearing-related QoL. Conclusions: Cochlear implantation provides a benefit in hearing-related QoL, even in some patients with low postoperative speech intelligibility results. Consequently, hearing-related QoL scores should be routinely used as outcome measure beside standard speech understanding tests, as well. Further studies with a prospective multi-centric design are needed to identify factors influencing post-implantation functional results and QoL in the patient group of long-term deafness.
Collapse
|
4
|
Roberts JB, Christopher Stecker G, Holder JT, Gifford RH. Combined Electric and Acoustic Stimulation (EAS) in Children: Investigating Benefit Afforded by Bilateral Versus Unilateral Acoustic Hearing. Otol Neurotol 2021; 42:e836-e843. [PMID: 33859136 PMCID: PMC8627183 DOI: 10.1097/mao.0000000000003139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE Electric and acoustic stimulation (EAS) with preserved hearing in the implanted ear provides benefit for speech understanding, spatial hearing, and quality of life in adults. However, there is limited research on EAS outcomes in children. The aims of this study were to estimate the magnitude of EAS-related benefit on speech understanding in children with preserved acoustic hearing and to determine what role acoustic interaural time difference (ITD) sensitivity may have on said EAS benefit. METHODS Six children with acoustic hearing preservation and 20 children with normal hearing (NH) were recruited to participate. Speech recognition was assessed via an eight-loudspeaker array with speech presented from one loudspeaker at 0 degree and restaurant noise from all other loudspeakers (45-315 degrees). ITD thresholds were measured for a 250-Hz signal presented acoustically via insert earphones. RESULTS Only one EAS listener demonstrated significant benefit from bilateral acoustic hearing as compared with acoustic hearing from a single ear. ITD thresholds were poor in the range of 302 to 1000+ ms and were considerably poorer than ITD thresholds for the NH group. CONCLUSION These data suggest that children with acoustic hearing preservation may not exhibit initial EAS benefit for speech recognition in semi-diffuse noise; however, because none exhibited a decrement in performance with bilateral acoustic stimulation, EAS fittings are recommended to provide binaural acoustic access allowing for EAS adaptation to binaural cues over time. Future research should address the emergence of EAS benefit, binaural cue sensitivity, and the role of EAS experience in children and adults.
Collapse
|
5
|
Schwam ZG, Kaul VF, Perez E, Wanna GB, Cosetti MK. Initial Experience With a Recently Developed Lateral Wall Electrode. Laryngoscope 2021; 131:2782-2788. [PMID: 34296451 DOI: 10.1002/lary.29779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2021] [Revised: 07/07/2021] [Accepted: 07/15/2021] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To review our hearing preservation rates and speech recognition outcomes in patients undergoing cochlear implantation with a recently developed lateral wall electrode. STUDY DESIGN Retrospective cohort study. METHODS Retrospective case series of all patients, both pediatric and adult, undergoing cochlear implantation with the Advanced Bionics Hifocus™ SlimJ electrode between December 2017 and January 2020. Main outcomes included hearing preservation rates using several definitions, speech recognition testing primarily through Arizona Biosciences (AzBio) and Consonant-Nucleus-Consonant (CNC) testing, intra- and postoperative complications. RESULTS Sixty-one ears underwent implantation with the new electrode. Hearing preservation rates were 13.0% to 36.0% depending on the definition used. Speech recognition testing showed significant increases from pre- to postoperative condition (Implant-only AzBio: 24.1 to 48.3, P = .004, binaural AzBio: 46.1 to 65.9, P = .002, Implant-only CNC: 9.7 to 35.1, P < .001, binaural CNC: 29.8 to 59.40, P < .001) with last speech recognition testing occurring an average of 8.8 months postoperatively. The elderly population had the worst hearing preservation rates across all definitions. Five explantations were required due to two infections and three device failures. CONCLUSION Hearing preservation rates varied significantly depending on the definition used, but users experienced a significant improvement in speech recognition testing after implantation. More work is needed in the community to standardize the definition of residual hearing and hearing preservation. LEVEL OF EVIDENCE 4 Laryngoscope, 2021.
Collapse
Affiliation(s)
- Zachary G Schwam
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.,Department of Otolaryngology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, U.S.A
| | - Vivian F Kaul
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.,Department of Otolaryngology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, U.S.A
| | - Enrique Perez
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.,Department of Otolaryngology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, U.S.A
| | - George B Wanna
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.,Department of Otolaryngology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, U.S.A
| | - Maura K Cosetti
- Department of Otolaryngology-Head and Neck Surgery, Icahn School of Medicine at Mount Sinai, New York, New York, U.S.A.,Department of Otolaryngology, New York Eye and Ear Infirmary of Mount Sinai, New York, New York, U.S.A
| |
Collapse
|
6
|
Bilateral Cochlear Implants or Bimodal Hearing for Children with Bilateral Sensorineural Hearing Loss. CURRENT OTORHINOLARYNGOLOGY REPORTS 2021; 8:385-394. [PMID: 33815965 DOI: 10.1007/s40136-020-00314-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Purpose of review This review describes speech perception and language outcomes for children using bimodal hearing (cochlear implant (CI) plus contralateral hearing aid) as compared to children with bilateral CIs and contrasts said findings with the adult literature. There is a lack of clinical evidence driving recommendations for bimodal versus bilateral CI candidacy and as such, clinicians are often unsure about when to recommend a second CI for children with residual acoustic hearing. Thus the goal of this review is to identify scientific information that may influence clinical decision making for pediatric CI candidates with residual acoustic hearing. Recent findings Bilateral CIs are considered standard of care for children with bilateral severe-to-profound sensorineural hearing loss. For children with aidable acoustic hearing-even in just the low frequencies-an early period of bimodal stimulation has been associated with significantly better speech perception, vocabulary, and language development. HA audibility, however, is generally poorer than that offered by a CI resulting in interaural asymmetry in speech perception, head shadow, as well as brainstem and cortical activity and development. Thus there is a need to optimize "two-eared" hearing while maximizing a child's potential with respect to hearing, speech, and language while ensuring that we limit asymmetrically driven auditory neuroplasticity. A recent large study of bimodal and bilateral CI users suggested that a period of bimodal stimulation was only beneficial for children with a better-ear pure tone average (PTA) ≤ 73 dB HL. This 73-dB-HL cutoff applied even to children who ultimately received bilateral CIs. Summary Though we do not yet have definitive guidelines for determining bimodal versus bilateral CI candidacy, there is increasing evidence that 1) bilateral CIs yield superior outcomes for children with bilateral severe-to-profound hearing loss and, 2) an early period of bimodal stimulation is beneficial for speech perception and language development, but only for children with better-ear PTA ≤ 73 dB HL. For children with residual acoustic hearing, even in just the low-frequency range, rapid sequential bilateral cochlear implantation following a trial period with bimodal stimulation will yield best outcomes for auditory, language, and academic development. Of course, there is also an increasing prevalence of cochlear implantation with acoustic hearing preservation allowing for combined electric and acoustic stimulation even following bilateral implantation.
Collapse
|
7
|
Woodson E, Nelson RC, Smeal M, Haberkamp T, Sydlowski S. Initial hearing preservation outcomes of cochlear implantation with a slim perimodiolar electrode array. Cochlear Implants Int 2021; 22:148-156. [PMID: 33443000 DOI: 10.1080/14670100.2020.1858553] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To assess the slim modiolar array as a hearing preservation electrode. METHODS Retrospective chart review of adult, post-lingual CI recipients implanted with slim modiolar array Sept 2016 to July 2017 in a tertiary referral center. Baseline audiograms were obtained within six months of initial CI evaluation. Patients with low frequency pure tone average (LFPTA) (125, 250, 500 Hz) <80 dB were considered HP candidates. Postoperative audiograms were obtained within 48 h before activation. Successful HP was considered as (1) retention of LFPTA threshold <80 dB and (2) change in threshold from pre- to post-operative. RESULTS Sixty-three patients received the slim perimodiolar array and 42 were HP candidates. Post-operative audiograms were obtained for 39 of 42 patients an average of 28.92 days after surgery. 56.4% of HP candidates retainedLFPTA <80 dB. Mean ΔLFPTA was 24.15 dB (±16.14; p < 0.001). 56.4% of HP candidates experienced Δ LFPTA <20 dB; 69.2% <30 dB. Functional hearing preservation was more successful in lower frequencies where starting thresholds were better - 78% with LFPTA <50 dB retained serviceable hearing at activation. The postoperative change was similar in each low frequency (Δ125 Hz: mean 21.25 +/- 14.76 (N = 28); Δ250 Hz: 26.28 +/- 19.29 (N = 39); Δ500 Hz: 25.00 +/- 17.73 (N = 39)). CONCLUSIONS The slim perimodiolar array is moderately effective at immediate hearing preservation. In subjects with preoperative audiometric profiles similar to those in prior EAS trials, immediate HP is comparable.
Collapse
Affiliation(s)
- Erika Woodson
- Cleveland Clinic Head and Neck Institute, Cleveland, OH, USA
| | | | - Molly Smeal
- Cleveland Clinic Head and Neck Institute, Cleveland, OH, USA
| | | | - Sarah Sydlowski
- Cleveland Clinic Head and Neck Institute, Cleveland, OH, USA
| |
Collapse
|
8
|
Spitzer ER, Waltzman SB, Landsberger DM, Friedmann DR. Acceptance and Benefits of Electro-Acoustic Stimulation for Conventional-Length Electrode Arrays. Audiol Neurootol 2020; 26:17-26. [PMID: 32721977 DOI: 10.1159/000507975] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Accepted: 04/17/2020] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Prior studies have shown an advantage for electro-acoustic stimulation (EAS) in cochlear implant (CI) patients with residual hearing, but the degree of benefit can vary. The objective was to explore which factors relate to performance with and acceptance of EAS for CI users with conventional-length electrodes. METHODS A retrospective chart review was conducted for adults with an average threshold of 75 dB hearing loss or better across 250 and 500 Hz preoperatively (n = 83). All patients underwent cochlear implantation with a conventional-length electrode. Low-frequency audiometric thresholds were measured at initial activation as well as 3 and 12 months postoperatively to determine who met the criteria for EAS. Speech perception for CNC words and AzBio sentences in quiet and +10 dB SNR noise was evaluated 3 and 12 months after activation. RESULTS Speech perception in quiet and noise was similar regardless of whether or not the patient was eligible for EAS. Less than half of the patients who met the EAS criteria chose to use it, citing reasons such as physical discomfort or lack of perceived benefit. EAS users performed better on CNC words but not sentence recognition than EAS nonusers. CONCLUSIONS EAS use is dependent on audiologic and nonaudiologic issues. Hearing preservation is possible with conventional electrodes, but hearing preservation alone does not guarantee superior speech perception.
Collapse
Affiliation(s)
- Emily R Spitzer
- Department of Otolaryngology - Head and Neck Surgery, New York University School of Medicine, New York, New York, USA
| | - Susan B Waltzman
- Department of Otolaryngology - Head and Neck Surgery, New York University School of Medicine, New York, New York, USA
| | - David M Landsberger
- Department of Otolaryngology - Head and Neck Surgery, New York University School of Medicine, New York, New York, USA
| | - David R Friedmann
- Department of Otolaryngology - Head and Neck Surgery, New York University School of Medicine, New York, New York, USA,
| |
Collapse
|
9
|
|
10
|
Abstract
INTRODUCTION A modern cochlear implant electrode array design must combine: improved surgical ease of use, structure preservation, particularly important for pediatric application, stable position within the cochlea over time, and a meaningful balance between hearing preservation against addressing sufficient cochlear tissue to support electrical-only hearing. The aim of this study was to investigate a new lateral wall electrode array design from Advanced Bionics on human temporal bones (TBs). METHODS Ten fresh-frozen TBs were implanted with the SlimJ electrode array via the round window. The electrode array is 23 mm long, with a cross-section varying from 0.25 × 0.55 mm at the most apical contact to 0.6 × 0.8 mm at the proximal marker contact. To assess location of the electrode array, the TBs were postoperatively scanned using cone beam computed tomography, and histology was performed to assess intracochlear trauma (Grades 0-4). RESULTS All electrode arrays were considered easy to insert. The average insertion depth was 432 degrees measured from the round window with a range from 411 to 450 degrees azimuth. Nine out of 10 electrode arrays were inserted fully (<0.5 mm out of the cochlea), one electrode array was left 1.5 mm out of the cochlea. No translocations were observed in all 10 cochleae, slight touching of the basilar membrane at the distal portion of the array was observed in 50% of the cases. CONCLUSION The results from the new thin lateral wall electrode array from Advanced Bionics provided consistent scala tympani locations. No translocations were observed and almost all electrode arrays were fully inserted. These results are promising and the new electrode array will be further studied in clinical practice investigating hearing preservation capabilities and speech performance.
Collapse
|
11
|
Assessing Cochlear Implant Insertion Angle From an Intraoperative X-ray Using a Rotating 3D Helical Scala Tympani Model. Otol Neurotol 2020; 41:e686-e694. [DOI: 10.1097/mao.0000000000002638] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
12
|
Comparison of a Mid Scala and a Perimodiolar Electrode in Adults: Performance, Impedances, and Psychophysics. Otol Neurotol 2020; 41:467-475. [PMID: 32176125 DOI: 10.1097/mao.0000000000002579] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The HiFocus Mid-Scala electrode array (HFms) is designed to sit within the scala tympani without touching either the lateral wall or the modiolus. The aim of this study was to compare the HFms to the Helix perimodiolar electrode array. METHOD Two groups of recipients with Helix (n = 22 ears) and HFms (n = 29 ears) electrode arrays were retrospectively identified and matched by age at implantation and duration of severe to profound deafness. Most comfortable listening levels (M), impedances, Freiburger Monosyllables in quiet, and Oldenburg sentences in adaptive noise were compared at 3, 6, and 12 months postimplant. RESULTS Median scores for monosyllables in quiet for the HFms group were significantly better than the Helix group at each test interval (p < 0.05). Speech perception in quiet also significantly improved from 3 to 12 months for both groups (p < 0.001). There was no significant difference between the groups for speech in noise. Impedances were significantly lower for the HFms group at 12 months (p < 0.05) except at the basal end and M levels were generally higher. CONCLUSIONS The HFms group had better median performance for monosyllables in quiet than the Helix group at each test interval, although performance in noise was similar. For speech in noise, the HFms group appear to reach optimum performance quicker than the Helix group. Impedances were lower in the HFms group across the array, other than at the most basal end, and support our hypothesis that the HFms assumes a more lateral position within the cochlea than the Helix electrode, although our article did not include imaging data.
Collapse
|
13
|
Slim Perimodiolar Arrays Are as Effective as Slim Lateral Wall Arrays for Functional Hearing Preservation After Cochlear Implantation. Otol Neurotol 2020; 41:e674-e679. [DOI: 10.1097/mao.0000000000002622] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
14
|
Outcomes for a clinically representative cohort of hearing-impaired adults using the Nucleus® CI532 cochlear implant. Eur Arch Otorhinolaryngol 2020; 277:1625-1635. [PMID: 32140773 PMCID: PMC7198645 DOI: 10.1007/s00405-020-05893-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Accepted: 02/17/2020] [Indexed: 11/03/2022]
Abstract
PURPOSE Hearing performance data was collected from a large heterogeneous group of subjects implanted with the Cochlear™ Nucleus® CI532 with Slim Modiolar Electrode, for the purposes of postmarket clinical follow-up. Data was analysed for factors which may predict postoperative speech recognition scores. METHODS Data was collected retrospectively from five German clinics for 159 subjects from March 2017 to August 2018. Hearing thresholds and recognition scores for monosyllabic words in quiet and sentences in noise were measured preoperatively and at 3 and 6 months postoperatively. RESULTS There was a mean gain of 44% points (95% CI 39-49%) at 6 months in monosyllable scores in quiet for implanted ears. Preoperative hearing thresholds in implant ears increased systematically with decreasing age; however, younger subjects had better baseline monosyllable scores with hearing aids compared with older subjects. Baseline performance alone explained 14% of the variation in postoperative scores. Residual hearing was preserved on average to within 22 dB at 250 Hz and 30 dB at 500 Hz of preoperative levels. CONCLUSIONS In a large and varied cohort of routinely treated hearing-impaired adults, speech recognition with the CI532 for German monosyllabic words in quiet at 6 months was equivalent to performance reported at one year or more in other published studies. Although younger subjects had poorer preoperative pure-tone thresholds, they had better preoperative word recognition scores compared with older subjects, and also had higher post implant scores. Further research is required to identify if this phenomenon is just applicable to German health system assessment and referral practices.
Collapse
|
15
|
Comparison of Skull Radiograph and Computed Tomography Measurements of Cochlear Implant Insertion Angles. Otol Neurotol 2020; 40:e298-e303. [PMID: 30741910 DOI: 10.1097/mao.0000000000002121] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Measurement of the angular depth of insertion (aDOI) of cochlear implant electrode arrays has numerous clinical and research applications. Plain-film radiographs are easily obtained intraoperatively and have been described as a means to calculate aDOI. CT imaging with 3D reformatting can also be used for this measurement, but is less conveniently obtained and requires higher radiation doses, a particular concern in pediatrics. The extent to which plain-film and 3D CT image-based measurements are representative of the true position of the electrode within the cochlea is unknown. METHODS Cochlear implantation was performed on 10 cadaveric temporal bones. Five bones were implanted with perimodiolar electrodes (Contour Advance TM, Cochlear, Sydney, Australia) and five were implanted with lateral wall electrodes (Slim Straight, Cochlear). The insertion depths of the electrodes were varied. Each bone was imaged with a radiograph and CT. aDOI was measured for each bone in each imaging modality by a neurotologist and a neuroradiologist. To obtain a 'gold standard' estimate of aDOI, the implanted temporal bones were embedded in an epoxy resin and methodically sectioned at 100 μm intervals; histologic images were captured at each interval. A 3D stack of the images was compounded, and a MATLAB script used to calculate aDOI of the most apical electrode. Measurements in the three modalities (radiograph, CT, and histology) were then compared. RESULTS The average aDOI across all bones was similar for all modalities: 423° for radiographs, 425° for CT scans, and 427° for histology, indicating that neither imaging modality resulted in large systematic errors. Using the histology-measured angles as a reference, the average error for CT-based measures (regardless of whether the error was in the positive or negative direction) was 12°, and that for radiograph-based measures was 15°. This small difference (12 vs 15° error) was not statistically significant. CONCLUSION Based on this cadaveric temporal bone model, both radiographs and CTs can provide reasonably accurate aDOI measurements. In this small sample, and as expected, the CT-based estimates were more accurate than the radiograph-based measurements. However, the difference was small and not statistically significant. Thus, the use of plain radiographs to calculate aDOI seems judicious whenever it is desired to prevent unnecessary radiation exposure and expense.
Collapse
|
16
|
Ishiyama A, Risi F, Boyd P. Potential insertion complications with cochlear implant electrodes. Cochlear Implants Int 2020; 21:206-219. [PMID: 32079506 DOI: 10.1080/14670100.2020.1730066] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Objectives: The aim of this discussion paper and literature review was to estimate the incidence of a variety of complications associated with the surgical placement of cochlear implant (CI) electrode arrays and to discuss the implications and management of sub-optimal electrode placement. Results: A review of the peer-reviewed literature suggests that the incidence of incomplete electrode insertion and kinking is more prevalent in straight arrays and not more than about 2% in CI recipients with normal cochlear anatomy/patency. Incidence of tip fold-over is greater with perimodiolar arrays but also occurs with straight arrays and is typically less than 5%. Conversely, electrode migration is more common with straight arrays, and high rates (up to 46%) have been reported in some studies. Scalar translocations have also been reported for both perimodiolar and straight arrays. Higher rates have been reported for stylet-based perimodiolar electrodes inserted via cochleostomy (up to 56%), but with much lower rates (<10%) with both sheath-based perimodiolar arrays and lateral wall arrays. Electrode positioning complications represent a significant proportion of perioperative CI complications and compromise the level of benefit from the device. Careful surgical planning and appropriate pre- and intraoperative imaging can reduce the likelihood and impact of electrode positioning complications. There is also evidence that newer array designs are less prone to certain complications, particularly scalar translocation. Conclusions: It is important that implanting surgeons are aware of the impact of sub-optimal electrode placement and the steps that can be taken to avoid, identify and manage such complications.
Collapse
Affiliation(s)
- Akira Ishiyama
- Rehabilitation Center, 1000 Veteran Ave., Los Angeles, CA, USA
| | - Frank Risi
- Clinical Affairs, Cochlear Ltd, Macquarie University, Sydney, Australia
| | - Paul Boyd
- Clinical Affairs, Cochlear Ltd, Macquarie University, Sydney, Australia
| |
Collapse
|
17
|
The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion. Otol Neurotol 2019; 39:e1019-e1025. [PMID: 30444847 DOI: 10.1097/mao.0000000000002045] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To investigate the results of clinical surgical insertions with a Mid-scala array (HIFocus Mid-Scala Electrode, HFms). STUDY DESIGN Consecutive retrospective case study. SETTINGS Tertiary referral center. PATIENTS Analyses of imaging data of 26 consecutive patients (31 insertions) implanted with the HFms. INTERVENTION (S) The evaluation of insertion trauma evoked by a previously validated image fusion technique. Electrode reconstructions from postoperative cone-beam computed tomography (CBCT) were overlaid onto preoperative magnetic resonance imaging (MRI) scans to create artifact-free images. MAIN OUTCOME MEASURES The electrode position was quantified in relation to the basilar membrane. Trauma scaling adopted from Eshraghi was used for evaluating insertion trauma. The results of the visual assessment of the postoperative CBCT were compared to those obtained with the fusion technique. RESULTS Three insertions had to be excluded due to incompatibility of the imaging data with the fusion software. We found consistent peri- to mid-modiolar placement of the HFms with a mean insertion depth angle of 376°. According to the medical records, a visual examination of the postoperative CBCT indicated that there had been no scala dislocations but when assessed by the image fusion technique, five scala dislocations (17.8%) were found. Additionally, one tip fold-over was detected in the postoperative CBCT even though this was not evident in any intraoperative measurements. CONCLUSION HFms showed atraumatic surgical insertion results with consistent mid-modiolar placement. Image fusion enhances the accuracy of the insertion trauma assessment. Routine postoperative imaging is recommended for identifying tip fold-over as well as for quality control and documentation.
Collapse
|
18
|
Vu TH, Perazzini C, Puechmaille M, Bachy A, Mulliez A, Boyer L, Mom T, Gabrillargues J. CT-scan contouring technique allows for direct and reliable measurements of the cochlear duct length: implication in cochlear implantation with straight electrode-arrays. Eur Arch Otorhinolaryngol 2019; 276:2135-2140. [PMID: 31011800 DOI: 10.1007/s00405-019-05432-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2019] [Accepted: 04/12/2019] [Indexed: 10/27/2022]
Abstract
OBJECTIVES The advent of hybrid electro-acoustic implants requires precise positioning of the electrode-array (EA) within the cochlea. The cochlea size, that is, the length of the cochlear scala tympani, is often indirectly estimated from distance A by Escudé's method. This technique has been confirmed by anatomical studies, in a bunch of cadaveric specimens, but it is not yet widely established in the field of computed tomography (CT). We compared cochlear duct length obtained by Escudé's method to those directly acquired on CT images. MATERIALS AND METHODS The lengths of cochlear scala tympani were directly measured on CT scans by contouring the external cochlear wall (contouring technique-CoT). In fifteen patients implanted with a straight EA, the length of the EA and the measured length of the cochlea by the CoT were compared, to check the reliability of the CoT. Then, in 200 CT-scans, the length of the cochlear duct was measured by the CoT then compared to Escudé's method. RESULTS In the 200 CT-scans which served for cochlear length measurements, a significant variability between the cochleae were observed, as expected. At 360°, the correlation between the measurements of the length of the cochlear scala tympani between the two techniques differed, with a difference of 0.2 ± 0.7 mm at 360° (extreme: 2 mm; p < 0.001) and 2.2 ± 1.2 mm at 540° (extreme: 5.6 mm; p < 0.001). CONCLUSION The CoT can predict with accuracy the length of EA-insertion depth, more precisely than estimation methods such as Escudé's.
Collapse
Affiliation(s)
- Thi Hau Vu
- Department of Radiology, Hôpital Bach Mai, Université de Médecine de Ha Noi, 78 Giai Phong, Dong Da, Ha Noi, Viet Nam.,Department of Radiology, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France
| | - Chiara Perazzini
- Department of Radiology, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France
| | - Mathilde Puechmaille
- Department of Otolaryngology Head and Neck Surgery, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France.,Unité Mixte de Recherche de l'Institut National des Sciences et de la Recherche en Médecine (UMR-INSERM, 1107), Laboratory of Neurosensory Biophysics, Université Clermont Auvergne, 63000, Clermont-Ferrand, France
| | - Aurélie Bachy
- Department of Otolaryngology Head and Neck Surgery, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France
| | - Aurélien Mulliez
- Délégation à la Recherche Clinique et aux Innovations, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France
| | - Louis Boyer
- Department of Radiology, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France.,Cardiovascular Interventional Therapy and Imaging (CaVITI Team), Therapy Guided By Imaging Institute (TGI-Institut Pascal), Unité Mixte de Recherche 6602 du Centre National de la Recherche Scientifique (UMR-CNRS), Université Clermont Auvergne, UCA/CNRS/SIGMA, Campus Universitaire des Cézeaux, 4 Avenue Blaise Pascal, Clermont-Ferrand, France
| | - Thierry Mom
- Department of Otolaryngology Head and Neck Surgery, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France. .,Unité Mixte de Recherche de l'Institut National des Sciences et de la Recherche en Médecine (UMR-INSERM, 1107), Laboratory of Neurosensory Biophysics, Université Clermont Auvergne, 63000, Clermont-Ferrand, France.
| | - Jean Gabrillargues
- Department of Radiology, CHU Gabriel Montpied, Université Clermont Auvergne, 58 Rue Montalembert, 63000, Clermont-Ferrand, France
| |
Collapse
|
19
|
|
20
|
Evaluation of a new slim lateral wall electrode for cochlear implantation: an imaging study in human temporal bones. Eur Arch Otorhinolaryngol 2018; 275:1723-1729. [DOI: 10.1007/s00405-018-5004-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2018] [Accepted: 05/16/2018] [Indexed: 11/26/2022]
|
21
|
Survey of the American Neurotology Society on Cochlear Implantation: Part 2, Surgical and Device-Related Practice Patterns. Otol Neurotol 2018; 39:e20-e27. [DOI: 10.1097/mao.0000000000001631] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
22
|
O'Connell BP, Hunter JB, Haynes DS, Holder JT, Dedmon MM, Noble JH, Dawant BM, Wanna GB. Insertion depth impacts speech perception and hearing preservation for lateral wall electrodes. Laryngoscope 2017; 127:2352-2357. [PMID: 28304096 DOI: 10.1002/lary.26467] [Citation(s) in RCA: 121] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2016] [Revised: 11/11/2016] [Accepted: 11/22/2016] [Indexed: 11/06/2022]
Abstract
OBJECTIVES 1) Examine angular insertion depths (AID) and scalar location of Med-El (GmbH Innsbruck, Austria) electrodes; and 2) determine the relationship between AID and audiologic outcomes controlling for scalar position. STUDY DESIGN Retrospective review. METHODS Postlingually deafened adults undergoing cochlear implantation with Flex 24, Flex 28, and Standard electrode arrays (Med-El) were identified. Patients with preoperative and postoperative computed tomography scans were included so that electrode location and AID could be determined. Outcome measures were 1) speech perception in the cochlear implant (CI)-only condition, and 2) short-term hearing preservation. RESULTS Forty-eight implants were included; all electrodes (48 of 48) were positioned entirely within the scala tympani. The median AID was 408° (interquartile [IQ] range 373°-449°) for Flex 24, 575° (IQ range 465°-584°) for Flex 28, and 584° (IQ range 368°-643°) for Standard electrodes (Med-El). The mean postoperative CNC score was 43.7% ± 21.9. A positive correlation was observed between greater AID and better CNC performance (r = 0.48, P < 0.001). Excluding patients with postoperative residual hearing, a strong correlation between AID and CNC persisted (r = 0.57, P < 0.001). In patients with preoperative residual hearing, mean low-frequency pure-tone average (PTA) shift was 27 dB ± 14. A correlation between AID and low-frequency PTA shift at activation was noted (r = 0.41, P = 0.04). CONCLUSION Favorable rates of scala tympani insertion (100%) were observed. In the CI-only condition, a direct correlation between greater AID and CNC score was noted regardless of postoperative hearing status. Deeper insertions were, however, associated with worse short-term hearing preservation. When patients without postoperative residual hearing were analyzed independently, the relationship between greater insertion depth and better performance was strengthened. LEVEL OF EVIDENCE 4. Laryngoscope, 127:2352-2357, 2017.
Collapse
Affiliation(s)
- Brendan P O'Connell
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jacob B Hunter
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - David S Haynes
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jourdan T Holder
- Department of Hearing and Speech Sciences, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Matt M Dedmon
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Jack H Noble
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - Benoit M Dawant
- Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee, U.S.A
| | - George B Wanna
- Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University, Nashville, Tennessee, U.S.A
| |
Collapse
|