1
|
Choi CH, Choi JH, Che SH, Kim JY. The radiographic and clinical outcomes of stemless reverse total shoulder arthroplasty: a minimum 2-year follow-up study. Clin Shoulder Elb 2024:cise.2024.00472. [PMID: 39419632 DOI: 10.5397/cise.2024.00472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2024] [Accepted: 08/26/2024] [Indexed: 10/19/2024] Open
Abstract
Background The purpose of this study was to examine the radiographic and clinical outcomes of stemless reverse total shoulder arthroplasty (RTSA) after a minimum 2-year follow-up. Methods Between July 2018 and March 2023, 50 patients underwent 50 stemless RTSA with the Lima component. Twenty-eight patients with a follow-up of more than 2 years were reviewed. The average age was 71.9 years (range, 61-85 years), and the average follow-up period was 2.2 years (range, 2.0-5.1). Bone marrow density of the proximal humerus was measured before RTSA. We evaluated preoperative and postoperative range of motion, clinical score, radiographic change, and postoperative complications. Results Significant increases were observed postoperatively in forward flexion (112.0º-162.5º, P<0.01) and internal rotation (from L3 to T12 level; P<0.05). No changes were observed in external rotation (from 43.0º to 45.2º; P=0.762). The clinical scores improved for Korean Shoulder Scoring system (from 64 to 93, P<0.01) and American Shoulder and Elbow Surgeons score (from 17.5 to 27.3, P<0.01). Although radiolucent lines of less than 2 mm were observed in all cases, no osteolysis and loosening of the stemless humeral component was found. Scapular notching was observed in 18 cases (64.3%). Conclusions Stemless RTSA showed good radiographic and clinical results after a minimum 2-year follow-up. Level of evidence: IV.
Collapse
Affiliation(s)
- Chang-Hyuk Choi
- Department of Orthopedic Surgery, Daegu Catholic University School of Medicine, Daegu, Korea
| | - Ji Hoon Choi
- Department of Orthopedic Surgery, Daegu Catholic University School of Medicine, Daegu, Korea
| | - Sug Hun Che
- Department of Orthopedic Surgery, Daegu Catholic University School of Medicine, Daegu, Korea
| | - Jun-Young Kim
- Department of Orthopedic Surgery, Daegu Catholic University School of Medicine, Daegu, Korea
| |
Collapse
|
2
|
Moroder P, Siegert P, Coifman I, Rüttershoff K, Spagna G, Scaini A, Weber B, Schneller T, Scheibel M, Audigé L. Scapulothoracic orientation has a significant influence on the clinical outcome after reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2024; 33:2159-2170. [PMID: 38537767 DOI: 10.1016/j.jse.2024.02.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/14/2023] [Revised: 02/01/2024] [Accepted: 02/03/2024] [Indexed: 06/22/2024]
Abstract
BACKGROUND Computer simulation has indicated a significant effect of scapulothoracic orientation and posture on range of motion (ROM) after reverse total shoulder arthroplasty (RTSA). We analyzed this putative effect on the clinical and radiologic outcome post-RTSA. METHODS We retrospectively assessed 2-year follow-up data of RTSA patients treated at our clinic between 2008 and 2019. Patients were categorized into posture types A, B, and C based on an established method using scapular internal rotation on preoperative cross-sectional imaging. We compared differences in clinical ROM, pain, Subjective Shoulder Value, Constant Score, Shoulder Pain and Disability Index (SPADI), quality of life (EuroQol-5 Dimensions-5 Level utility index), and radiologic outcomes between posture types using linear regression analyses. RESULTS Of 681 included patients, 225 had type A posture, 326 type B, and 130 type C. Baseline group characteristics were comparable, although the type C group had a higher proportion of females (60% [A], 64% [B], 80% [C]) with lower abduction strength (0.7 kg [A], 0.6 kg [B], 0.3 kg [C]) and a slightly higher proportion with a Grammont design RTSA (41% [A], 48% [B], 54% [C]). There were significant adjusted differences in mean (±standard deviation) active flexion (A: 137° ± 21°; B: 136° ± 20°; C: 131° ± 19°) and passive flexion (A: 140° ± 19°; B: 138° ± 19°; C: 134° ± 18°), active (A: 127° ± 26°; B: 125° ± 26°; C: 117° ± 27°) and passive abduction (A: 129° ± 24°; B: 128° ± 25°; C: 121° ± 25°), SPADI (A: 81 ± 18; B: 79 ± 20; C: 73 ± 23), and pain (A: 1.2 ± 1.7; B: 1.6 ± 2.2; C: 1.8 ± 2.4) between posture types at 2 years (P ≤ .035). A higher distalization shoulder angle was associated with better abduction in type C patients (P = .016). Type C patients showed a trend toward a higher complication rate (3.9% vs. 1.1% [A], 3.2% [B]) (P = .067). CONCLUSIONS Type C posture influences the 2-year clinical outcome of RTSA patients in terms of worse flexion, abduction, SPADI, and pain. Scapulothoracic orientation and posture should be considered during the patient selection process, preoperative planning, and implantation of an RTSA.
Collapse
Affiliation(s)
- Philipp Moroder
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Paul Siegert
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland; Orthopaedic Department, Orthopaedic Hospital Speising, Vienna, Austria.
| | - Ismael Coifman
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | | | - Giovanni Spagna
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Alessandra Scaini
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland
| | - Beatrice Weber
- Research and Development, Schulthess Clinic, Zurich, Switzerland
| | - Tim Schneller
- Research and Development, Schulthess Clinic, Zurich, Switzerland
| | - Markus Scheibel
- Department of Shoulder and Elbow Surgery, Schulthess Clinic, Zurich, Switzerland; Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Laurent Audigé
- Research and Development, Schulthess Clinic, Zurich, Switzerland; University Hospital Basel, Basel, Switzerland
| |
Collapse
|
3
|
Bauer S, Blakeney WG, Lannes X, Wang AW, Shao W. Optimizing stability and motion in reverse shoulder arthroplasty with a 135° neck-shaft-angle: a computer model study of standard versus retentive humeral inserts. JSES Int 2024; 8:1087-1094. [PMID: 39280143 PMCID: PMC11401560 DOI: 10.1016/j.jseint.2024.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/18/2024] Open
Abstract
Background There has been a trend to shift from a 155° and 145° neck-shaft-angle (NSA) to a more "anatomical" reverse shoulder arthroplasty with less distalization and a 135° NSA. Multiple studies have shown that a 135° NSA is beneficial for motion. There are some concerns about primary implant stability with a 135° NSA. When instability is detected, increasing the tension with thicker inlays or changing the NSA to 145° are possible solutions. A retentive 135° (Ret135) inlay may be an alternative to avoiding increased distalization; however, retentive liners are widely regarded as salvage options reducing range of motion (ROM) and avoided by most surgeons. The hypothesis of this study was that a retentive 135° insert of the tested implant system may not have drawbacks for impingement-free ROM compared to a standard 145° insert (Sta145). Methods In this computer model study, 22 computed tomographic scans (11 males/11 females) were used to create models with a constant humeral stem (Perform/Stryker) and +3 mm lateralized baseplate +36 mm glenosphere for females and +6 mm lateralized baseplate +39 mm glenosphere for males using Blueprint software (Imascap, Brest, France). A Ret135, standard 135° (Sta135), and Sta145 (+10°) insert were compared for adduction (ADD), extension (EXT), external rotation (ER), and internal rotation (IR) all with the arm at the side as well as for combined IR (CIR = EXT + IR) and combined notching relevant (CNR) ROM (EXT + ER + IR + ADD). Results Sta135 showed significantly better ROM for ER, IR, ADD, EXT, CNR ROM, and CIR compared to Ret135 (P < .05) and significantly better EXT and ADD compared to Sta145 (P < .0001). Comparison of Ret135 and Sta145 showed equivalent ROM performance, which was slightly better but nonsignificant for ADD (P = .16), EXT (P = .31), CNR ROM (P = .7), and CIR (P = .54) in favor of Ret135. Isolated IR (P = .39) and ER (P = .32) were slightly better but nonsignificant in favor of a Sta145. Conclusion For this implant system tested in a computer model, a 135° standard liner offers the best ROM. A 135° retentive liner maintains at least equivalent CIR and motion to prevent notching compared to a standard 145° liner. 135° retentive liners are more than salvage options and may help to prevent distalization and overtensioning by increased liner thickness.
Collapse
Affiliation(s)
- Stefan Bauer
- Centre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland
- School of Surgery, University of Western Australia, Perth, WA, Australia
| | - William G Blakeney
- School of Surgery, University of Western Australia, Perth, WA, Australia
- Department of Orthopaedic Surgery, Royal Perth Hospital, Perth, WA, Australia
| | - Xavier Lannes
- Centre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland
| | - Allan W Wang
- School of Surgery, University of Western Australia, Perth, WA, Australia
| | - Wei Shao
- Centre de l'épaule et du membre supérieur de la Côte, Ensemble Hospitalier de la Côte, Morges, Switzerland
| |
Collapse
|
4
|
Ranieri R, Minelli M, Borroni M, Delle Rose G, Dubini L, Castagna A. Inverted-bearing reverse shoulder arthroplasty: long-term survivorship, complications, clinical, and radiological outcomes. J Shoulder Elbow Surg 2024:S1058-2746(24)00386-0. [PMID: 38810915 DOI: 10.1016/j.jse.2024.03.069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2023] [Revised: 03/14/2024] [Accepted: 03/29/2024] [Indexed: 05/31/2024]
Abstract
BACKGROUND Inverted-bearing reverse shoulder arthroplasty (IB-RSA) is characterized by a polyethylene glenosphere and a metallic humeral liner to minimize polyethylene wear and debris secondary to impingement between the humerus and glenoid neck. IB-RSA long-term survivorship, complication and revision rates, as well as clinical and radiographic outcomes have not been reported yet. METHODS This is a monocentric retrospective study on a consecutive series of 151 patients who underwent primary IB-RSA from January 2009 to September 2015 and were evaluated clinically and radiologically at the minimum 8-year follow-up. All complications and reoperations were recorded. Survivorship analysis with any revision surgery as endpoint was done using Kaplan-Meier survival curves. RESULTS Seventy-eight patients (follow-up rate 51.7%) were reviewed at a mean follow-up of 10.1 ± 1.9 years. At 10 years, the revision-free survival was 98.7% (95% confidence interval: 94.8-99.7). Sixteen complications (10.6%) were observed: 2 axillary nerve injuries, 2 infections, 2 glenoid loosening (which stabilized within 1 year), 2 cases of otherwise unexplained painful stiffness, 4 acromial fractures, 1 post-traumatic scapular pillar fracture, and 3 post-traumatic humeral periprosthetic fractures. Two patients were revised due to infection. No cases of late glenoid loosening and humeral loosening were observed. The revision rate was 1.3%. All the clinical scores and range of motion significantly improved at the last follow-up compared with preoperative status: final Constant score was 66.1 ± 17.4, Subjective Shoulder Value 79.1 ± 20.9, and the American Shoulder and Elbow Surgeons 82.2 ± 17.7. Scapular notching was observed in 51.4% of patients: only 1 case of grade 3 notching was observed in an early glenoid subsidence case. CONCLUSIONS Primary IB-RSA appears to be a safe and effective procedure and does not present specific implant-associated complications at long-term follow-up. Radiographic analysis showed that inverting the biomaterials leads to a distinct kind of notching with mainly mechanical features.
Collapse
Affiliation(s)
- Riccardo Ranieri
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
| | - Marco Minelli
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy.
| | - Mario Borroni
- IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| | | | - Luigi Dubini
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
| | - Alessandro Castagna
- Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy; IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
| |
Collapse
|
5
|
Pak T, Menendez ME, Gobezie R, Sears BW, Lederman E, Werner BC, Denard PJ. Rates of subacromial notching are low following reverse shoulder arthroplasty with a 135° inlay humeral component and a lateralized glenoid. JSES Int 2024; 8:522-527. [PMID: 38707585 PMCID: PMC11064686 DOI: 10.1016/j.jseint.2024.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/07/2024] Open
Abstract
Background Lateralization in reverse shoulder arthroplasty (RSA) decreases bony impingement and improves rotational range of motion, but has been theorized to increase the risk of subacromial notching (SaN). The purpose of this study was to evaluate the presence of SaN following RSA and its relationship with lateralization with a 135° inlay humeral component. The secondary purpose was to assess the association of SaN with functional outcomes. Methods A retrospective review was performed from a multicenter prospectively collected database on patients who underwent primary RSA from 2015 to 2021. All RSAs were performed with a 135° inlay humeral component. SaN was defined as bony erosion with sclerotic margins on the undersurface of the acromion on final follow-up radiographs not present preoperatively. Postoperative implant positioning (inclination, distalization, and lateralization) were evaluated on minimum 1-year postoperative radiographs. Regression analyses were performed on implant and clinical variables to assess for risk factors. A separate analysis was performed to determine the association of SaN with clinical outcomes. Results SaN was identified in 13 out of 442 shoulders (2.9%). Age, sex, body mass index, smoking status, diabetes mellitus, arm dominance had no relationship with SaN. Neither glenoid sided lateralization nor humeral offset were associated with SaN risk. Other implant characteristics such as distalization, glenosphere size, and postoperative inclination did not influence SaN risk. The presence of SaN did not affect patient-reported outcomes (American Shoulder and Elbow Surgeons: P = .357, Visual Analog Scale: P = .210) or range of motion. Conclusion The rate of SaN is low and not associated with glenoid or humeral prosthetic lateralization when using a 135° inlay humeral component. When SaN occurs, it is not associated with functional outcomes or range of motion at short-term follow-up.
Collapse
Affiliation(s)
- Theresa Pak
- Center for Orthopedic Research and Education, Phoenix, AZ, USA
| | | | | | | | - Evan Lederman
- University of Arizona College of Medicine – Phoenix, Phoenix, AZ, USA
| | - Brian C. Werner
- University of Virginia Health System, Charlottesville, VA, USA
| | | |
Collapse
|
6
|
Haase L, Ina J, Harlow E, Chen R, Gillespie R, Calcei J. The Influence of Component Design and Positioning on Soft-Tissue Tensioning and Complications in Reverse Total Shoulder Arthroplasty: A Review. JBJS Rev 2024; 12:01874474-202404000-00002. [PMID: 38574183 DOI: 10.2106/jbjs.rvw.23.00238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/06/2024]
Abstract
» Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.» Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.» Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.» A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.
Collapse
Affiliation(s)
- Lucas Haase
- University Hospitals of Cleveland, Cleveland, Ohio
| | | | | | | | | | | |
Collapse
|
7
|
Tarallo L, Giorgini A, Micheloni G, Montanari M, Porcellini G, Catani F. Navigation in reverse shoulder arthroplasty: how the lateralization of glenosphere can affect the clinical outcome. Arch Orthop Trauma Surg 2023; 143:5649-5656. [PMID: 37074371 PMCID: PMC10115375 DOI: 10.1007/s00402-023-04879-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 04/04/2023] [Indexed: 04/20/2023]
Abstract
INTRODUCTION One of the main causes of RSA failure is attributable to the malpositioning of the glenoid component. Initial experiences with computer-assisted surgery have shown promising results in increasing the accuracy and repeatability of placement of the glenoid component and screws. The aim of this study was to evaluate the functional clinical results, in terms of joint mobility and pain, by correlating them with intraoperative data regarding the positioning of the glenoid component. The hypothesis was that the lateralization more than 25 mm of the glenosphere can led to better stability of the prosthesis but should pay in term of a reduced range of movement and increased pain. MATERIALS AND METHODS 50 patients were enrolled between October 2018 and May 2022; they underwent RSA implantation assisted by GPS navigation system. Active ROM, ASES score and VAS pain scale were recorded before surgery. Preoperative data about glenoid inclination and version were collected by pre-op X-Rays an CT. Intraoperative data-inclination, version, medialization and lateralization of the glenoid component-were recorded using computer-assisted surgery. 46 patients had been further clinically and radiographically re-evaluated at 3-months, 6-months, 1-year, and 2-years follow-up. RESULTS We found a statistically significant correlation between anteposition and glenosphere lateralization value (DM - 6.057 mm; p = 0.043). Furthermore a statistically significant correlation has been shown between abduction movement and the lateralization value (DM - 7.723 mm; p = 0.015). No other statistically significant associations were found when comparing the values of glenoid inclination and version with the range of motion achieved by the patients after reverse shoulder arthroplasty. CONCLUSION We observed that the patients with the best anteposition and abduction results had a glenosphere lateralization between 18 and 22 mm. When increasing the lateralization above 22 mm or reducing it below 18 mm, on the other hand, both movements considered decreased their range. LEVEL OF EVIDENCE Level IV; Case Series; Treatment Study.
Collapse
Affiliation(s)
- Luigi Tarallo
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy.
| | - Andrea Giorgini
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy
| | - Gianmario Micheloni
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy
| | - Marta Montanari
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy
| | - Giuseppe Porcellini
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy
| | - Fabio Catani
- Orthopedics and Traumatology Department, University of Modena and Reggio Emilia - Modena, Via del Pozzo 71, 41125, Modena, Italy
| |
Collapse
|
8
|
Yoon DJY, Odri GA, Favard L, Samargandi R, Berhouet J. Preoperative Planning for Reverse Shoulder Arthroplasty: Does the Clinical Range of Motion Match the Planned 3D Humeral Displacement? J Pers Med 2023; 13:jpm13050771. [PMID: 37240941 DOI: 10.3390/jpm13050771] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2023] [Revised: 04/22/2023] [Accepted: 04/24/2023] [Indexed: 05/28/2023] Open
Abstract
INTRODUCTION The functional outcome after reverse shoulder arthroplasty (RSA) is closely linked to how much the humerus shifts because of the implants. While two-dimensional (2D) angle measurements have been used to capture this shift, it can be measured in three dimensions (3D) as the arm change position (ACP). In a previous study, the ACP was measured using 3D preoperative planning software with the passive virtual shoulder range of motion obtained after RSA. The main objective of this study was to evaluate the relationship between the ACP and the actual active shoulder range of motion measured after RSA. The hypothesis was that the ACP and the active clinical range of motion are related such that the ACP is a reliable parameter to guide the preoperative planning of an RSA. The secondary objective was to assess the relationship between 2D and 3D humeral displacement measurements. MATERIALS AND METHODS This prospective observational study enrolled 12 patients who underwent RSA and had a minimum follow-up of 2 years. The active range of motion in shoulder flexion, abduction, and internal and external rotation was measured. At the same time, ACP measurements were taken from a reconstructed postoperative CT scan, in addition to the radiographic measurements of humeral lateralization and distalization angles on AP views in neutral rotation. RESULTS The mean humeral distalization induced by RSA was 33.3 mm (±3.8 mm). A non-statistically significant increase in shoulder flexion was observed for humeral distalization beyond 38 mm (R2 = 0.29, p = 0.07). This "threshold" effect of humeral distalization was also observed for the gains in abduction, as well as internal and external rotations, which seemed better with less than 38 mm or even 35 mm distalization. No statistical correlation was found between the 3D ACP measurements and 2D angle measurements. CONCLUSION Excessive humeral distalization seems to be detrimental to joint mobility, especially shoulder flexion. Humeral lateralization and humeral anteriorization measured using the ACP seem to promote better shoulder range of motion, with no threshold effect. These findings could be evidence of tension in the soft tissues around the shoulder joint, which should be taken into consideration during preoperative planning.
Collapse
Affiliation(s)
- Diane Ji Yun Yoon
- Service de Chirurgie Orthopédique et Traumatologique, CHRU Trousseau, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Chambray-les-Tours, France
- Inserm U1132 BIOSCAR, Université Paris Cité, 75010 Paris, France
| | - Guillaume-Anthony Odri
- Inserm U1132 BIOSCAR, Université Paris Cité, 75010 Paris, France
- Service de Chirurgie Orthopédique et Traumatologique, Centre Hospitalier Universitaire Lariboisière, 75010 Paris, France
| | - Luc Favard
- Service de Chirurgie Orthopédique et Traumatologique, CHRU Trousseau, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Chambray-les-Tours, France
| | - Ramy Samargandi
- Service de Chirurgie Orthopédique et Traumatologique, CHRU Trousseau, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Chambray-les-Tours, France
- Department of Orthopedic Surgery, Faculty of Medicine, University of Jeddah, Jeddah 23218, Saudi Arabia
| | - Julien Berhouet
- Service de Chirurgie Orthopédique et Traumatologique, CHRU Trousseau, Faculté de Médecine de Tours, Université de Tours, 1C Avenue de la République, 37170 Chambray-les-Tours, France
- Equipe Reconnaissance de Forme et Analyse de l'Image, Laboratoire d'Informatique Fondamentale et Appliquée de Tours EA6300, Ecole d'Ingénieurs Polytechnique Universitaire de Tours, Université de Tours, 64 Avenue Portalis, 37200 Tours, France
| |
Collapse
|
9
|
Computer-assisted analysis of functional internal rotation after reverse total shoulder arthroplasty: implications for component choice and orientation. J Exp Orthop 2023; 10:23. [PMID: 36917396 PMCID: PMC10014642 DOI: 10.1186/s40634-023-00580-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 01/25/2023] [Indexed: 03/16/2023] Open
Abstract
PURPOSE Functional internal rotation (IR) is a combination of extension and IR. It is clinically often limited after reverse total shoulder arthroplasty (RTSA) either due to loss of extension or IR in extension. It was the purpose of this study to determine the ideal in-vitro combination of glenoid and humeral components to achieve impingement-free functional IR. METHODS RTSA components were virtually implanted into a normal scapula (previously established with a statistical shape model) and into a corresponding humerus using a computer planning program (CASPA). Baseline glenoid configuration consisted of a 28 mm baseplate placed flush with the posteroinferior glenoid rim, a baseplate inclination angle of 96° (relative to the supraspinatus fossa) and a 36 mm standard glenosphere. Baseline humeral configuration consisted of a 12 mm humeral stem, a metaphysis with a neck shaft angle (NSA) of 155° (+ 6 mm medial offset), anatomic torsion of -20° and a symmetric PE inlay (36mmx0mm). Additional configurations with different humeral torsion (-20°, + 10°), NSA (135°, 145°, 155°), baseplate position, diameter, lateralization and inclination were tested. Glenohumeral extension of 5, 10, 20, and 40° was performed first, followed by IR of 20, 40, and 60° with the arm in extension of 40°-the value previously identified as necessary for satisfactory clinical functional IR. The different component combinations were taken through simulated ROM and the impingement volume (mm3) was recorded. Furthermore, the occurrence of impingement was read out in 5° motion increments. RESULTS In all cases where impingement occurred, it occurred between the PE inlay and the posterior glenoid rim. Only in 11 of 36 combinations full functional IR was possible without impingement. Anterosuperior baseplate positioning showed the highest impingement volume with every combination of NSA and torsion. A posteroinferiorly positioned 26 mm baseplate resulting in an additional 2 mm of inferior overhang as well as 6 mm baseplate lateralization offered the best impingement-free functional IR (5/6 combinations without impingement). Low impingement potential resulted from a combination of NSA 135° and + 10° torsion (4/6 combinations without impingement), followed by NSA 135° and -20° torsion (3/6 combinations without impingement) regardless of glenoid setup. CONCLUSION The largest impingement-free functional IRs resulted from combining a posteroinferior baseplate position, a greater inferior glenosphere overhang, 90° of baseplate inclination angle, 6 mm glenosphere lateralization with respect to baseline setup, a lower NSA and antetorsion of the humeral component. Surgeons can employ and combine these implant configurations to achieve and improve functional IR when planning and performing RTSA. LEVEL OF EVIDENCE Basic Science Study, Biomechanics.
Collapse
|
10
|
Challenges for Optimization of Reverse Shoulder Arthroplasty Part I: External Rotation, Extension and Internal Rotation. J Clin Med 2023; 12:jcm12051814. [PMID: 36902601 PMCID: PMC10003696 DOI: 10.3390/jcm12051814] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/06/2023] [Accepted: 02/16/2023] [Indexed: 03/06/2023] Open
Abstract
A detailed overview of the basic science and clinical literature reporting on the challenges for the optimization of reverse shoulder arthroplasty (RSA) is presented in two review articles. Part I looks at (I) external rotation and extension, (II) internal rotation and the analysis and discussion of the interplay of different factors influencing these challenges. In part II, we focus on (III) the conservation of sufficient subacromial and coracohumeral space, (IV) scapular posture and (V) moment arms and muscle tensioning. There is a need to define the criteria and algorithms for planning and execution of optimized, balanced RSA to improve the range of motion, function and longevity whilst minimizing complications. For an optimized RSA with the highest function, it is important not to overlook any of these challenges. This summary may be used as an aide memoire for RSA planning.
Collapse
|
11
|
Bauer S, Blakeney WG, Goyal N, Flayac H, Wang A, Corbaz J. Posteroinferior relevant scapular neck offset in reverse shoulder arthroplasty: key player for motion and friction-type impingement in a computer model. J Shoulder Elbow Surg 2022; 31:2638-2646. [PMID: 35931331 DOI: 10.1016/j.jse.2022.06.014] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 06/07/2022] [Accepted: 06/21/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND Range of motion (ROM) and prevention of notching remain a challenge for reverse shoulder arthroplasty (RSA). Both may be affected by the morphology of the scapula. The purpose of this study was to define anteroinferior (a) and posteroinferior (p) relevant scapular neck offset (RSNO) and to examine the hypothesis that pRSNO is significantly smaller than aRSNO, and influences rigid body motion (RBM). Adapting glenosphere implantation strategies may therefore be of value. MATERIAL AND METHODS In this computer model study, we used deidentified computed tomographic scans of 22 patients (11 male and 11 female; mean age: 72.9 years) with massive cuff tears without joint space narrowing. Eight RSA glenoid configurations were tested with a constant neck-shaft angle (145°). Two baseplate types (25 mm; 25 + 3 mm lateralized) and 4 glenospheres (GS) (36 mm; 36 +2 mm of eccentricity; 39 mm; 39 + 3 mm) were used. RSNO was defined as the standardized measurement of the horizontal distance from the inferior extent of the GS to the bony margin of the scapula after baseplate positioning (flush to inferior glenoid extent; neutral position: 0° inclination and 0° version-both software computed). RESULTS There was a highly significant difference between pRSNO and aRSNO for both genders (P < .001). pRSNO was always smaller than aRSNO. pRSNO was strongly correlated with external rotation (ERO: 0.84) and extension (EXT: 0.74) and moderately correlated with global ROM (GROM: 0.68). There was a moderately strong correlation between aRSNO and internal rotation (IRO: 0.69). pRSNO was strongly correlated with aRSNO, EXT, ERO, IRO, adduction (ADD) and GROM (0.82, 0.72, 0,8, 0.71, 0.82, 0.76) in female patients and with EXT and ERO (0.82, 0.89) in male patients. The median pRSNO allowing for at least 45° ERO and 40° EXT was 14.2 mm for men and 13.8 mm for women. For all patients and models, pRSNO ≥14 mm increased EXT, ERO, and GROM significantly compared with pRSNO <14 mm (P < .001). The combination of lateralization and inferior overhang (eccentricity) led to the most significant increase of pRSNO for each GS size (P < .001). CONCLUSION This is one of the first RSA modeling studies evaluating nonarthritic glenoids of both genders. The lateral scapular extent to glenoid relationship is asymmetric. pRSNO is always smaller than aRSNO for both genders and was a critical variable for EXT and ERO, demonstrating additional strong correlation with aRSNO, IRO, ADD, and GROM in female patients. pRSNO ≥14 mm was a safe value to prevent friction-type impingement. Combining increased glenosphere size, lateralization, and inferior overhang gives the best results in this computer-simulated setting.
Collapse
Affiliation(s)
- Stefan Bauer
- Ensemble Hospitalier de la Côte, Morges, Switzerland; University of Western Australia, Perth, Australia.
| | - William G Blakeney
- Royal Perth Hospital, Perth, Australia; University of Western Australia, Perth, Australia
| | - Navendu Goyal
- Ensemble Hospitalier de la Côte, Morges, Switzerland
| | | | - Allan Wang
- University of Western Australia, Perth, Australia
| | - Jocelyn Corbaz
- Ensemble Hospitalier de la Côte, Morges, Switzerland; Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| |
Collapse
|
12
|
Holschen M, Körting M, Khourdaji P, Bockmann B, Schulte TL, Witt KA, Steinbeck J. Treatment of proximal humerus fractures using reverse shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical outcome and tuberosity healing? Arch Orthop Trauma Surg 2022; 142:3817-3826. [PMID: 34977963 DOI: 10.1007/s00402-021-04281-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Accepted: 11/24/2021] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The employment of reverse shoulder arthroplasty for dislocated proximal humerus fractures of elderly patients becomes increasingly relevant. The standard inclination angle of the humeral component was 155°. Lately, there is a trend towards smaller inclination angles of 145° or 135°. Additionally, there has been an increased focus on the lateralization of the glenosphere. This retrospective comparative study evaluates clinical and radiological results of patients treated for proximal humerus fractures by reverse shoulder arthroplasty with different inclination angles of the humeral component, which was either 135° or 155°. Additionally, a different lateral offset of the glenosphere, which was either 0 mm or 4 mm, was used. METHODS For this retrospective comparative analysis, 58 out of 66 patients treated by reverse total shoulder arthroplasty for proximal humerus fractures were included. The minimum follow-up was 24 months. Thirty (m = 3, f = 27; mean age 78 years; mean FU 35 months, range 24-58 months) were treated with a standard 155° humeral component and a glenosphere without lateral offset (group A), while 28 patients (m = 2, f = 26; mean age 79 years; mean FU 30 months, range 24-46 months) were treated with a 135° humeral component and a glenosphere with a 4 mm lateral offset (group B). We determined range of motion, Constant score, and the American Shoulder and Elbow Surgeons Shoulder score as clinical outcomes and evaluated tuberosity healing as well as scapula notching. RESULTS Neither forward flexion (A = 128°, B = 121°; p = 0.710) nor abduction (A = 111°, B = 106°; p = 0.327) revealed differences between the groups. The mean Constant Score rated 63 in group A, while it was 61 in group B (p = 0.350). There were no differences of the ASES Score between the groups (A = 74, B = 72; p = 0.270). There was an increased risk for scapula notching in group A (47%) in comparison to group B (4%, p = 0.001). Healing of the greater tuberosity was achieved in 57% of group A and in 75% of group B (p = 0.142). The healing rate of the lesser tuberosity measured 33% in group A and 71% in group B (p = 0.004). CONCLUSIONS Both inclination angles of the humeral component are feasible options for the treatment of proximal humerus fractures in elderly patients. Neither the inclination angle nor the lateral offset of the glenosphere seem to have a relevant influence on the clinical outcome. The healing rate of the lesser tuberosity was higher in implants with a decreased neck-shaft angle. There is an increased risk for scapula notching, if a higher inclination angle of the humeral component is chosen. LEVEL OF EVIDENCE III. Retrospective comparative study.
Collapse
Affiliation(s)
- Malte Holschen
- Orthopedic Practice Clinic (OPPK), Von-Vincke-Str. 14, 48143, Münster, Germany.
- Raphaelsklinik, Loerstr. 23, 48143, Münster, Germany.
| | - Maria Körting
- Orthopedic Practice Clinic (OPPK), Von-Vincke-Str. 14, 48143, Münster, Germany
| | | | - Benjamin Bockmann
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Tobias L Schulte
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Kai-Axel Witt
- Orthopedic Practice Clinic (OPPK), Von-Vincke-Str. 14, 48143, Münster, Germany
| | - Jörn Steinbeck
- Orthopedic Practice Clinic (OPPK), Von-Vincke-Str. 14, 48143, Münster, Germany
| |
Collapse
|
13
|
Castagna A, Borroni M, Dubini L, Gumina S, Delle Rose G, Ranieri R. Inverted-Bearing Reverse Shoulder Arthroplasty: Consequences on Scapular Notching and Clinical Results at Mid-Term Follow-Up. J Clin Med 2022; 11:jcm11195796. [PMID: 36233664 PMCID: PMC9572577 DOI: 10.3390/jcm11195796] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 09/09/2022] [Accepted: 09/25/2022] [Indexed: 11/16/2022] Open
Abstract
Background: Scapular notching following reverse shoulder arthroplasty (RSA) is caused by both biological and mechanical mechanisms. Some authors postulated that osteolysis that extends over the inferior screw is caused mainly by biological notching. Inverted-bearing RSA (IB-RSA) is characterized by a polyethylene glenosphere and a metallic humeral liner, decreasing the poly debris formation and potentially reducing high grades of notching. This study aims to report the results of IB-RSA on a consecutive series of patients at mid-term follow-up, focusing on the incidence of Sirveaux grade 3 and 4 scapular notching. Methods: A retrospective study on 78 consecutive patients who underwent primary IB-RSA between 2015−2017 was performed. At a 4 years minimum follow-up, 49 patients were evaluated clinically with Constant score (CS), Subjective shoulder value (SSV), American Shoulder and Elbow score (ASES), pain and range of motion, and with an X-ray assessing baseplate position (high, low), implant loosening, and scapular notching. Results: At a mean follow-up of 5.0 ± 0.9, all the clinical parameters improved (p < 0.05). One patient was revised for an infection and was excluded from the evaluation, two patients had an acromial fracture, and one had an axillary neuropraxia. Scapular notching was present in 13 (27%) patients (six grade 1, seven grade 2) and no cases of grade 3 and 4 were observed. Scapular nothing was significantly associated with high glenoid position (p < 0.001) and with lower CS (70 ± 15 vs. 58 ± 20; p = 0.046), SSV (81 ± 14 vs. 68 ± 20; p = 0.027), ASES (86 ± 14 vs. 70 ± 22; p = 0.031), and anterior elevation (148 ± 23 vs. 115 ± 37; p = 0.006). A 44 mm- compared to 40 mm-glenosphere was associate with better CS (63 ± 17 vs. 78 ± 11; p = 0.006), external (23 ± 17 vs. 36 ± 17; p = 0.036), and internal rotation (4.8 ± 2.7 vs. 7.8 ± 2.2; p = 0.011). Conclusions: IB-RSA is a safe and effective procedure for mid-term follow-up. Inverting biomaterials leads to a distinct kind of notching with mainly mechanical features. Scapular notching is associated with a high baseplate position and has a negative influence on range of motion and clinical outcome.
Collapse
Affiliation(s)
- Alessandro Castagna
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Mario Borroni
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Luigi Dubini
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
| | - Stefano Gumina
- Department of Anatomy, Histology, Forensic Medicine and Orthopaedics, Sapienza University of Rome, Piazzale Aldo Moro 5, 00185 Roma, Italy
- Istituto Clinico Ortopedico Traumatologico (ICOT), Via Franco Faggiana 1668, 04100 Latina, Italy
| | - Giacomo Delle Rose
- IRCCS Humanitas Clinical and Research Center, Via Manzoni 56, Rozzano (Mi), 20089 Milan, Italy
| | - Riccardo Ranieri
- Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, Rozzano (Mi), 20090 Milan, Italy
- Correspondence: ; Tel.: +39-33-8857-1926
| |
Collapse
|
14
|
Warnhoff M, Jensen G, Lill H, Ellwein A. [Current trends in reverse fracture arthroplasty]. UNFALLCHIRURGIE (HEIDELBERG, GERMANY) 2022; 125:690-698. [PMID: 35861875 DOI: 10.1007/s00113-022-01211-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 06/27/2022] [Indexed: 06/15/2023]
Abstract
The reliable results of reverse arthroplasty have made this the preferred treatment method for non-reconstructable proximal humeral fractures. The individual consideration of the patient and the morphological features of the fractures are essential. Computed tomography (CT) images provide crucial information on the perfusion of the humeral head relevant for the prognosis and treatment. In this context a differentiation must be made between hard and soft criteria against a reconstruction. Tuberosities should be reduced whenever possible, because reverse arthroplasty with healed tuberosities provides a better range of motion and more strength for external rotation and anteversion, less complications and longer survival rates. In recent years the trend has been towards anatomical designs of prostheses with a humeral inclination of 135°. Revision rates for primary fracture prostheses are overall low with instability as the main reason for revision surgery, followed by periprosthetic fractures and infections. Reverse fracture arthroplasty has comparable or better clinical results compared to conservative treatment, osteosynthesis for geriatric patients, hemiarthroplasty and prosthesis implantation by elective surgery. Reverse arthroplasties, which were implanted in conditions of fracture sequelae, did not achieve significantly poorer clinical outcome at mid-term follow-up and can significantly improve shoulder function.
Collapse
Affiliation(s)
- M Warnhoff
- Klinik für Orthopädie und Unfallchirurgie, DIAKOVERE Friederikenstift, Humboldtstr. 5, 30169, Hannover, Deutschland.
| | - G Jensen
- Klinik für Orthopädie und Unfallchirurgie, DIAKOVERE Friederikenstift, Humboldtstr. 5, 30169, Hannover, Deutschland
| | - H Lill
- Klinik für Orthopädie und Unfallchirurgie, DIAKOVERE Friederikenstift, Humboldtstr. 5, 30169, Hannover, Deutschland
| | - A Ellwein
- Klinik für Orthopädie und Unfallchirurgie, DIAKOVERE Friederikenstift, Humboldtstr. 5, 30169, Hannover, Deutschland
| |
Collapse
|
15
|
Gauci MO, Chaoui J, Berhouet J, Jacquot A, Walch G, Boileau P. Can surgeons optimize range of motion and reduce scapulohumeral impingements in reverse shoulder arthroplasty? A computational study. Shoulder Elbow 2022; 14:385-394. [PMID: 35846405 PMCID: PMC9284303 DOI: 10.1177/1758573221994141] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 12/12/2020] [Accepted: 01/20/2021] [Indexed: 11/17/2022]
Abstract
BACKGROUND Early glenohumeral impingement leads to poor range of motion and notching in reverse shoulder arthroplasty. The aim was to find from planning software which implant configuration provides the best motions in reverse shoulder arthroplasty. PATIENTS AND METHODS Reverse shoulder arthroplasty planning (Glenosys) was made in 31 patients (12 men, 19 women, 76 ± 6 yo) and impingements were analyzed. Inlay (155°-inclined) and Onlay (145°-inclined) humeral designs were tested. Four configurations were tested for each shoulder: "INLAY": non-lateralized glenoid-inlay humerus, "BIO-INLAY": lateralized glenoid (BIO-RSA)-inlay humerus, "ONLAY": non-lateralized glenoid-onlay humerus, and "BIO-ONLAY": lateralized (BIO-RSA) glenoid-onlay humerus. RESULTS BIO-ONLAY and BIO-INLAY groups presented a significantly better result in all tested motion (p < 0.001 for all tests). BIO-ONLAY allowed a significantly better external rotation, extension and adduction than BIO-INLAY with decreased impingements with the pilar. BIO-INLAY presented a significantly better abduction. In abduction, an abutment of the greater tuberosity against the acromion was associated with a lower range of motion (p < 0.0001) and did not depend on the lateralization. CONCLUSION Glenoid lateralization delays the glenohumeral impingement in reverse shoulder arthroplasty and gives the best rotations, adduction and extension when associated with neutral inclination and humeral 145° inclination. Greater tuberosity abutment has to be avoided in abduction and the Inlay design provides the best abduction.
Collapse
Affiliation(s)
- Marc-Olivier Gauci
- Institut Universitaire Locomoteur et du Sport
(IULS), Unité de Recherche Clinique Côte d’Azur (UR2CA), CHU de Nice, Université Côte d’Azur
(UCA), Nice, France,Marc-Olivier Gauci, IULS, CHU de Nice, UR2CA,
Université Côte d'Azur, 30 Voie Romaine, CHU de Nice, Consultation de Chirurgie
orthopédique, Nice 06000, France.
| | | | | | | | - Gilles Walch
- Ramsay Générale de Santé, Hôpital Privé Jean
Mermoz, Lyon, France
| | - Pascal Boileau
- Institut Universitaire Locomoteur et du Sport
(IULS), Unité de Recherche Clinique Côte d’Azur (UR2CA), CHU de Nice, Université Côte d’Azur
(UCA), Nice, France
| |
Collapse
|
16
|
The arm change position: Additional information for optimizing range of motion after reverse shoulder arthroplasty. Orthop Traumatol Surg Res 2022; 108:103246. [PMID: 35167964 DOI: 10.1016/j.otsr.2022.103246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/12/2020] [Revised: 02/05/2021] [Accepted: 02/22/2021] [Indexed: 02/03/2023]
Abstract
INTRODUCTION The arm change position (ACP) is a new parameter for evaluating the humerus' 3D displacement following reverse shoulder arthroplasty (RSA) during 3D pre operative planning. The purpose of this study was to analyze the relationship between ACP variations after RSA and simulated passive joint mobility. The assumption is that the ACP will to help optimize the passive joint mobility of a RSA implant. METHODS In 30 degenerative shoulders, four shoulder surgeons planned a RSA with virtual motion analysis. After this analysis, each plan was revised to optimize the range of motion. Relationships between the differences in movement amplitude and the differences in ACP were evaluated. RESULTS Arm lengthening and humerus lateralization were significantly associated with better joint mobility in all three planes (frontal, sagittal and axial). They were equally important for improving external rotation, extension, flexion and adduction. Anterior displacement of the humerus improved both internal and external rotation. DISCUSSION The ACP is a useful preoperative planning parameter for RSA. It could help with selecting the best implant combination, as well as determining their position, in order to optimize the simulated passive mobility relative to humerus displacement after RSA. To validate the value of the ACP in clinical practice, a prospective study is needed in which the postoperative joint mobility is measured in vivo as a function of the ACP. LEVEL OF EVIDENCE III, case control study.
Collapse
|
17
|
Imam MA, Neumann J, Siebert W, Mai S, Verborgt O, Eckers F, Jacobs L, Meyer DC. Prospective multicentre mid-term clinical and radiological outcomes of 159 reverse total shoulder replacements and assessment of the influence of post-operative complications. Shoulder Elbow 2022; 14:169-180. [PMID: 35265183 PMCID: PMC8899321 DOI: 10.1177/1758573220977184] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2019] [Revised: 10/13/2020] [Accepted: 10/26/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND The aim of our prospective multicentre study is to evaluate the five-year follow-up outcomes of primary reverse shoulder replacement utilizing two different designs of glenoid baseplates. METHODS There were 159 reverse shoulder replacements (91 cemented and 68 uncemented stems, 67 Trabecular Metal baseplates and 92 Anatomical Shoulder baseplates in 152 patients (99 women) with a mean age of 74.5 (58-90) years. The principal diagnosis was rotator cuff arthropathy in 108 shoulders. RESULTS Clinical and functional results improved significantly overall; the adjusted Constant Murley score improved from 28.2 ± 13.3 pre-operatively to 75.5 ± 22.8 (p < 0.0001) and the mean Subjective Shoulder Value improved from 27.5 ± 20 to 73.8 ± 21.3 points (p < 0.0001). Radiologically, there was good bony stability in 88% and 86% of cemented and uncemented stems without significant impact on the Constant Murley score and Subjective Shoulder Value at one, two and five years post-surgery. There were no significant clinical differences between Trabecular Metal and Anatomical Shoulder baseplates at five years. There were four cases of intraoperative shaft fractures that were managed with cables. Although the Trabecular Metal baseplates showed better integration radiologically, there was no significant difference in the mean of Constant Murley, Subjective Shoulder Value and the range of motion depending on the grade of inferior scapular notching at one-, two- and five-year intervals. CONCLUSIONS Reverse total shoulder arthroplasty restores the function in shoulder with significant improvements in function and moderate complications with minor differences between both designs of baseplates that were not reflected clinically.
Collapse
Affiliation(s)
- Mohamed A Imam
- Shoulder and Elbow unit, Balgrist University Hospital, University of Zurich, Zurich, Switzerland,Rowley Bristow Orthopaedic Unit, Ashford and St Peter’s Hospital, Ashford, UK,Norwich Medical School, University of East Anglia, Norwich, UK,Mohamed A Imam, Department of Orthopaedic Surgery, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
| | - Jörg Neumann
- Department of Orthopaedic Surgery, HELIOS ENDO-Klinik Hamburg GmbH, Hamburg, Germany
| | - Werner Siebert
- Department of Orthopaedic Surgery, Vitos Orthopädische Klinik Kassel GmbH, Kassel, Germany
| | - Sabine Mai
- Department of Orthopaedic Surgery, Vitos Orthopädische Klinik Kassel GmbH, Kassel, Germany
| | - Olivier Verborgt
- Department of Orthopaedic Surgery, AZ Monica Hospital and University Hospital of Antwerp, Antwerpen, Belgium
| | - Franziska Eckers
- Shoulder and Elbow unit, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Leo Jacobs
- Department of Orthopaedic Surgery, Royal Oldham Hospital, Oldham, UK
| | - Dominik C Meyer
- Shoulder and Elbow unit, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
18
|
Frank JK, Siegert P, Plachel F, Heuberer PR, Huber S, Schanda JE. The Evolution of Reverse Total Shoulder Arthroplasty-From the First Steps to Novel Implant Designs and Surgical Techniques. J Clin Med 2022; 11:1512. [PMID: 35329837 PMCID: PMC8949196 DOI: 10.3390/jcm11061512] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Revised: 03/06/2022] [Accepted: 03/08/2022] [Indexed: 02/04/2023] Open
Abstract
PURPOSE OF REVIEW The purpose of this review is to summarize recent literature regarding the latest design modifications and biomechanical evolutions of reverse total shoulder arthroplasty and their impact on postoperative outcomes. RECENT FINDINGS Over the past decade, worldwide implantation rates of reverse total shoulder arthroplasty have drastically increased for various shoulder pathologies. While Paul Grammont's design principles first published in 1985 for reverse total shoulder arthroplasty remained unchanged, several adjustments were made to address postoperative clinical and biomechanical challenges such as implant glenoid loosening, scapular notching, or limited range of motion in order to maximize functional outcomes and increase the longevity of reverse total shoulder arthroplasty. However, the adequate and stable fixation of prosthetic components can be challenging, especially in massive osteoarthritis with concomitant bone loss. To overcome such issues, surgical navigation and patient-specific instruments may be a viable tool to improve accurate prosthetic component positioning. Nevertheless, larger clinical series on the accuracy and possible complications of this novel technique are still missing.
Collapse
Affiliation(s)
- Julia K. Frank
- Vienna Shoulder and Sports Clinic, Baumgasse 20A, 1030 Vienna, Austria
- Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with the AUVA, Donaueschingenstraße 13, 1200 Vienna, Austria;
| | - Paul Siegert
- 1st Orthopaedic Department, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130 Vienna, Austria;
- Michael Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130 Vienna, Austria
| | - Fabian Plachel
- Center for Musculoskeletal Surgery, Campus Mitte, Charité Universitaetsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany;
- Department of Orthopaedics and Traumatology, Paracelsus Medical University Salzburg, Müllner Hauptstraße 48, 5020 Salzburg, Austria
| | - Philipp R. Heuberer
- HealthPi Medical Center, Wollzeile 1/3, 1010 Vienna, Austria;
- Austrian Research Group for Regenerative and Orthopaedic Medicine, 1010 Vienna, Austria
| | - Stephanie Huber
- Ludwig Boltzmann Institute of Osteology at Hanusch Hospital of OEGK and AUVA Trauma Center Vienna-Meidling, 1140 Vienna, Austria;
| | - Jakob E. Schanda
- Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with the AUVA, Donaueschingenstraße 13, 1200 Vienna, Austria;
- Michael Ogon Laboratory for Orthopaedic Research, Orthopaedic Hospital Vienna-Speising, Speisinger Straße 109, 1130 Vienna, Austria
- AUVA Trauma Center Vienna-Meidling, Kundratstraße 37, 1120 Vienna, Austria
- Austrian Cluster for Tissue Regeneration, 1200 Vienna, Austria
| |
Collapse
|
19
|
Razmjou H, van Osnabrugge V, Anunciacion M, Nunn A, Drosdowech D, Roszkowski A, Szafirowicz A, Boljanovic D, Wainwright A, Nam D. Maximizing Muscle Function in Cuff-Deficient Shoulders: A Rehabilitation Proposal for Reverse Arthroplasty. J Shoulder Elb Arthroplast 2022; 5:24715492211023302. [PMID: 34993379 PMCID: PMC8492033 DOI: 10.1177/24715492211023302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 05/17/2021] [Indexed: 11/15/2022] Open
Abstract
Purpose The purpose of this review is to describe the role of altered joint biomechanics in reverse shoulder arthroplasty and to propose a rehabilitation protocol for a cuff-deficient glenohumeral joint based on the current evidence.Methods and Materials: The proposed rehabilitation incorporates the principles of pertinent muscle loading while considering risk factors and surgical complications. Results In light of altered function of shoulder muscles in reverse arthroplasty, scapular plane abduction should be more often utilized as it better activates deltoid, teres minor, upper trapezius, and serratus anterior. Given the absence of supraspinatus and infraspinatus and reduction of external rotation moment arm of the deltoid in reverse arthroplasty, significant recovery of external rotation may not occur, although an intact teres minor may assist external rotation in the elevated position. Conclusion Improving the efficiency of deltoid function before and after reverse shoulder arthroplasty is a key factor in the rehabilitation of the cuff deficient shoulders. Performing exercises in scapular plane and higher abduction angles activates deltoid and other important muscles more efficiently and optimizes surgical outcomes.
Collapse
Affiliation(s)
- Helen Razmjou
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada.,Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Varda van Osnabrugge
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Mark Anunciacion
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Andrea Nunn
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Darren Drosdowech
- Roth
- McFarlane Hand & Upper Limb Centre, St. Joseph's Health Care, London, Ontario, Canada.,Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, Western University, London, Ontario, Canada
| | - Ania Roszkowski
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Analia Szafirowicz
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada
| | - Dragana Boljanovic
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Amy Wainwright
- Holland Bone and Joint Program, Holland Orthoapaedic & Arthritic Centre, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Department of Physical Therapy, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| | - Diane Nam
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Division of Orthopedic Surgery, Department of Surgery, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.,Division of Orthopaedic Surgery, Department of Surgery, Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
20
|
Collotte P, Bercik M, Vieira TD, Walch G. Long-term Reverse Total Shoulder Arthroplasty Outcomes: The Effect of the Inferior Shifting of Glenoid Component Fixation. Clin Orthop Surg 2021; 13:505-512. [PMID: 34868500 PMCID: PMC8609210 DOI: 10.4055/cios20245] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 12/28/2020] [Accepted: 12/28/2020] [Indexed: 11/30/2022] Open
Abstract
Backgroud The 155° Grammont reverse shoulder replacement has a long track record of success, but also a high radiographic notching rate. The increased distance between the scapular pillar and the humeral component theoretically decreases postoperative notching. The glenoid component can be shifted inferiorly relative to the glenoid; however, there also is some concern that shifting the glenoid component too far inferiorly (inferior glenoid component overhang > 3.5 mm) may compromise long-term stability of the glenoid component. This study was conducted to determine if clinical outcomes, scapular notching, and complications vary with more inferior placement of the glenoid component. Methods A retrospective analysis of prospectively collected data was performed in order to compare radiographic outcomes (notching rate and signs of glenoid loosening or component disassembly) and clinical outcomes (range of motion, Constant score, subjective shoulder value, and complication rate) of all patients who underwent reverse shoulder replacement with the glenosphere positioned either flush with the inferior rim of the glenoid (flush group) or with at least 3.5 mm of inferior overhang (overhang group) at a minimum follow-up of 60 months. Ninety-seven patients ultimately met the inclusion criteria, with 41 patients with flush glenoid component and 56 patients with at least 3.5 mm of inferior overhang. Results Average follow-up was 97.8 months. The overhang group had a lower rate of radiographic notching (37% vs. 82.5%, p < 0.05), better clinical outcomes (improvement in Constant score: +40 vs. +32, p = 0.036), and higher subjective shoulder value (79 vs. 69, p = 0.026) than the flush group. No difference in complications between groups was found. Conclusions In this study, at least 3.5 mm of inferior glenosphere overhang relative to the inferior rim of the glenoid was associated with the lower notching rate without negative effect on the clinical outcomes in 155° Grammont-style reverse shoulder replacement. Therefore, no increase in complications should be expected when using this surgical technique.
Collapse
Affiliation(s)
- Philippe Collotte
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| | | | - Thais Dutra Vieira
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| | - Gilles Walch
- Centre Orthopedique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Generale de Sante, Hopital Prive Jean Mermoz, Lyon, France
| |
Collapse
|
21
|
Huang Y, Ernstbrunner L, Robinson DL, Lee PVS, Ackland DC. Complications of Reverse Total Shoulder Arthroplasty: A Computational Modelling Perspective. J Clin Med 2021; 10:5336. [PMID: 34830616 PMCID: PMC8625535 DOI: 10.3390/jcm10225336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 11/09/2021] [Accepted: 11/09/2021] [Indexed: 11/29/2022] Open
Abstract
Reverse total shoulder arthroplasty (RTSA) is an established treatment for elderly patients with irreparable rotator cuff tears, complex proximal humerus fractures, and revision arthroplasty; however, with the increasing indications for RTSA over the last decade and younger implant recipients, post-operative complications have become more frequent, which has driven advances in computational modeling and simulation of reverse shoulder biomechanics. The objective of this study was to provide a review of previously published studies that employed computational modeling to investigate complications associated with RTSA. Models and applications were reviewed and categorized into four possible complications that included scapular notching, component loosening, glenohumeral joint instability, and acromial and scapular spine fracture, all of which remain a common cause of significant functional impairment and revision surgery. The computational shoulder modeling studies reviewed were primarily used to investigate the effects of implant design, intraoperative component placement, and surgical technique on postoperative shoulder biomechanics after RTSA, with the findings ultimately used to elucidate and mitigate complications. The most significant challenge associated with the development of computational models is in the encapsulation of patient-specific anatomy and surgical planning. The findings of this review provide a basis for future direction in computational modeling of the reverse shoulder.
Collapse
Affiliation(s)
- Yichen Huang
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia; (Y.H.); (L.E.); (D.L.R.); (P.V.S.L.)
| | - Lukas Ernstbrunner
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia; (Y.H.); (L.E.); (D.L.R.); (P.V.S.L.)
- Department of Orthopaedic Surgery, Royal Melbourne Hospital, Parkville, VIC 3050, Australia
- Melbourne Orthopaedic Group, Windsor, VIC 3181, Australia
| | - Dale L. Robinson
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia; (Y.H.); (L.E.); (D.L.R.); (P.V.S.L.)
| | - Peter Vee Sin Lee
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia; (Y.H.); (L.E.); (D.L.R.); (P.V.S.L.)
| | - David C. Ackland
- Department of Biomedical Engineering, University of Melbourne, Parkville, VIC 3010, Australia; (Y.H.); (L.E.); (D.L.R.); (P.V.S.L.)
| |
Collapse
|
22
|
Nabergoj M, Denard PJ, Collin P, Trebše R, Lädermann A. Mechanical complications and fractures after reverse shoulder arthroplasty related to different design types and their rates: part I. EFORT Open Rev 2021; 6:1097-1108. [PMID: 34909228 PMCID: PMC8631242 DOI: 10.1302/2058-5241.6.210039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The initial reverse shoulder arthroplasty (RSA), designed by Paul Grammont, was intended to treat rotator cuff tear arthropathy in elderly patients. In the early experience, high complication rates (up to 24%) and revision rates (up to 50%) were reported.The most common complications reported were scapular notching, whereas clinically more relevant complications such as instability and acromial fractures were less commonly described.Zumstein et al defined a 'complication' following RSA as any intraoperative or postoperative event that was likely to have a negative influence on the patient's final outcome.High rates of complications related to the Grammont RSA design led to development of non-Grammont designs, with 135 or 145 degrees of humeral inclination, multiple options for glenosphere size and eccentricity, improved baseplate fixation which facilitated glenoid-sided lateralization, and the option of humeral-sided lateralization.Improved implant characteristics combined with surgeon experience led to a dramatic fall in the majority of complications. However, we still lack a suitable solution for several complications, such as acromial stress fracture. Cite this article: EFORT Open Rev 2021;6:1097-1108. DOI: 10.1302/2058-5241.6.210039.
Collapse
Affiliation(s)
- Marko Nabergoj
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Patrick J. Denard
- Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, Oregon, USA
| | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, Ankaran, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
23
|
Serrano N, Kissling M, Krafft H, Link K, Ullrich O, Buck FM, Mathews S, Serowy S, Gascho D, Grüninger P, Fornaciari P, Bouaicha S, Müller-Gerbl M, Rühli FJ, Eppler E. CT-based and morphological comparison of glenoid inclination and version angles and mineralisation distribution in human body donors. BMC Musculoskelet Disord 2021; 22:849. [PMID: 34610804 PMCID: PMC8493698 DOI: 10.1186/s12891-021-04660-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2021] [Accepted: 08/25/2021] [Indexed: 11/11/2022] Open
Abstract
Background For optimal prosthetic anchoring in omarthritis surgery, a differentiated knowledge on the mineralisation distribution of the glenoid is important. However, database on the mineralisation of diseased joints and potential relations with glenoid angles is limited. Methods Shoulder specimens from ten female and nine male body donors with an average age of 81.5 years were investigated. Using 3D-CT-multiplanar reconstruction, glenoid inclination and retroversion angles were measured, and osteoarthritis signs graded. Computed Tomography-Osteoabsorptiometry (CT-OAM) is an established method to determine the subchondral bone plate mineralisation, which has been demonstrated to serve as marker for the long-term loading history of joints. Based on mineralisation distribution mappings of healthy shoulder specimens, physiological and different CT-OAM patterns were compared with glenoid angles. Results Osteoarthritis grades were 0-I in 52.6% of the 3D-CT-scans, grades II-III in 34.3%, and grade IV in 13.2%, with in females twice as frequently (45%) higher grades (III, IV) than in males (22%, III). The average inclination angle was 8.4°. In glenoids with inclination ≤10°, mineralisation was predominantly centrally distributed and tended to shift more cranially when the inclination raised to > 10°. The average retroversion angle was − 5.2°. A dorsally enhanced mineralisation distribution was found in glenoids with versions from − 15.9° to + 1.7°. A predominantly centrally distributed mineralisation was accompanied by a narrower range of retroversion angles between − 10° to − 0.4°. Conclusions This study is one of the first to combine CT-based analyses of glenoid angles and mineralisation distribution in an elderly population. The data set is limited to 19 individuals, however, indicates that superior inclination between 0° and 10°-15°, and dorsal version ranging between − 9° to − 3° may be predominantly associated with anterior and central mineralisation patterns previously classified as physiological for the shoulder joint. The current basic research findings may serve as basic data set for future studies addressing the glenoid geometry for treatment planning in omarthritis. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-04660-4.
Collapse
Affiliation(s)
- Nabil Serrano
- Institute of Evolutionary Medicine (IEM), University of Zurich, Zurich, Switzerland
| | - Marc Kissling
- Institute of Anatomy, University of Bern, Bern, Switzerland
| | - Hannah Krafft
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Karl Link
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland.,Anatomy, University of Fribourg, Fribourg, Switzerland
| | - Oliver Ullrich
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Florian M Buck
- Medical Radiology Institute, Schulthess Clinic, Zurich, Switzerland
| | - Sandra Mathews
- Institute of Evolutionary Medicine (IEM), University of Zurich, Zurich, Switzerland
| | - Steffen Serowy
- Clinic of Neuroradiology, University Hospital of Magdeburg, Magdeburg, Germany
| | - Dominic Gascho
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | | | - Paolo Fornaciari
- Department of Orthopaedics, Balgrist University Hospital, Zurich, Switzerland.,Department of Orthopaedic Surgery and Traumatology, University Hospital Fribourg, Fribourg, Switzerland
| | - Samy Bouaicha
- Department of Orthopaedics, Balgrist University Hospital, Zurich, Switzerland
| | - Magdalena Müller-Gerbl
- Musculoskeletal Research, Department of Biomedicine, University of Basel, Basel, Switzerland
| | - Frank-Jakobus Rühli
- Institute of Evolutionary Medicine (IEM), University of Zurich, Zurich, Switzerland.
| | - Elisabeth Eppler
- Musculoskeletal Research, Department of Biomedicine, University of Basel, Basel, Switzerland. .,Clinic of Neuroradiology, University Hospital of Magdeburg, Magdeburg, Germany. .,Institute of Anatomy, University of Bern, Bern, Switzerland.
| |
Collapse
|
24
|
Goetti P, Denard PJ, Collin P, Ibrahim M, Mazzolari A, Lädermann A. Biomechanics of anatomic and reverse shoulder arthroplasty. EFORT Open Rev 2021; 6:918-931. [PMID: 34760291 PMCID: PMC8559568 DOI: 10.1302/2058-5241.6.210014] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
The biomechanics of the shoulder relies on careful balancing between stability and mobility. A thorough understanding of normal and degenerative shoulder anatomy is necessary, as the goal of anatomic total shoulder arthroplasty is to reproduce premorbid shoulder kinematics.With reported joint reaction forces up to 2.4 times bodyweight, failure to restore anatomy and therefore provide a stable fulcrum will result in early implant failure secondary to glenoid loosening.The high variability of proximal humeral anatomy can be addressed with modular stems or stemless humeral components. The development of three-dimensional planning has led to a better understanding of the complex nature of glenoid bone deformity in eccentric osteoarthritis.The treatment of cuff tear arthropathy patients was revolutionized by the arrival of Grammont's reverse shoulder arthroplasty. The initial design medialized the centre of rotation and distalized the humerus, allowing up to a 42% increase in the deltoid moment arm.More modern reverse designs have maintained the element of restored stability but sought a more anatomic postoperative position to minimize complications and maximize rotational range of motion. Cite this article: EFORT Open Rev 2021;6:918-931. DOI: 10.1302/2058-5241.6.210014.
Collapse
Affiliation(s)
- Patrick Goetti
- Division of Orthopaedics and Trauma Surgery, Centre Hospitalier |Universitaire Vaudois, Lausanne, Switzerland
| | - Patrick J. Denard
- Denard Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, Oregon, United States
| | - Philippe Collin
- Collin Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint- Grégoire, France
| | - Mohamed Ibrahim
- Mohamed Ibrahim, Department of Orthopaedics and Trauma Surgery, Faculty of Medicine, Fayoum University, Fayoum, Egypt
| | - Adrien Mazzolari
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| |
Collapse
|
25
|
Nabergoj M, Onishi S, Lädermann A, Kalache H, Trebše R, Bothorel H, Collin P. Can Lateralization of Reverse Shoulder Arthroplasty Improve Active External Rotation in Patients with Preoperative Fatty Infiltration of the Infraspinatus and Teres Minor? J Clin Med 2021; 10:jcm10184130. [PMID: 34575241 PMCID: PMC8468982 DOI: 10.3390/jcm10184130] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/28/2021] [Accepted: 09/08/2021] [Indexed: 11/16/2022] Open
Abstract
(1) Background: Postoperative recovery of external rotation after reverse shoulder arthroplasty (RSA) has been reported despite nonfunctional external rotator muscles. Thus, this study aimed to clinically determine the ideal prosthetic design allowing external rotation recovery in such a cohort. (2) Methods: A monocentric comparative study was retrospectively performed on patients who had primary RSA between June 2013 and February 2018 with a significant preoperative fatty infiltration of the infraspinatus and teres minor. Two groups were formed with patients with a lateral humerus/lateral glenoid 145° onlay RSA-the onlay group (OG), and a medial humerus/lateral glenoid 155° inlay RSA-the inlay group (IG). Patients were matched 1:1 by age, gender, indication, preoperative range of motion (ROM), and Constant score. The ROM and Constant scores were assessed preoperatively and at a minimum follow-up of two years. (3) Results: Forty-seven patients have been included (23 in OG and 24 in IG). Postoperative external rotation increased significantly in the OG only (p = 0.049), and its postoperative value was significantly greater than that of the IG by 11.1° (p = 0.028). (4) Conclusion: The use of a lateralized humeral stem with a low neck-shaft angle resulted in significantly improved external rotation compared to a medialized humeral 155° stem, even in cases of severe fatty infiltration of the infraspinatus and teres minor. Humeral lateralization and a low neck-shaft angle should be favored when planning an RSA in a patient without a functional posterior rotator cuff.
Collapse
Affiliation(s)
- Marko Nabergoj
- Valdoltra Orthopaedic Hospital, 6280 Ankaran, Slovenia; (M.N.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Shinzo Onishi
- Department of Orthopaedic Surgery, Faculty of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan;
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, 1217 Meyrin, Switzerland
- Faculty of Medicine, University of Geneva, 1211 Geneva, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, 1205 Geneva, Switzerland
- Correspondence: ; Tel.: +41-22-719-75-55
| | - Houssam Kalache
- Hôpital Saint-Camille, 2 Rue des Pères Camilliens, 94360 Bry-sur-Marne, France;
| | - Rihard Trebše
- Valdoltra Orthopaedic Hospital, 6280 Ankaran, Slovenia; (M.N.); (R.T.)
- Faculty of Medicine, University of Ljubljana, Vrazov trg 2, 1000 Ljubljana, Slovenia
| | - Hugo Bothorel
- Research Department, La Tour Hospital, 1217 Meyrin, Switzerland;
| | - Philippe Collin
- Clinique Victor Hugo 5 Bis Rue du Dôme, 75116 Paris, France;
| |
Collapse
|
26
|
Collotte P, Erickson J, Vieira TD, Domos P, Walch G. Clinical and radiologic outcomes of eccentric glenosphere versus concentric glenosphere in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2021; 30:1899-1906. [PMID: 33276160 DOI: 10.1016/j.jse.2020.10.032] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 10/28/2020] [Accepted: 10/30/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The use of an eccentric glenosphere (EG) has been proposed as a way to prevent scapular notching in reverse shoulder arthroplasty (RSA). The purpose of this study was to investigate whether the use of an EG decreases scapular notching compared with matched standard concentric glenosphere (CG) controls. METHODS A retrospective analysis was performed. This study included 49 RSAs with an EG and 49 paired RSAs with a CG with a minimum 60 months of both clinical and radiographic follow-up. Clinical and radiologic outcomes of the EG and CG groups were compared at inclusion and at the last follow-up using the paired Student t test for quantitative data and the χ2 test for qualitative data. Scapular notching was graded according to the Sirveaux classification. Statistical significance was set at P < .05. RESULTS Notching was observed 2.7 times (95% confidence interval, 1.0-6.8 times) more often in the CG group (P = .037). The difference in notching severity between the groups was not statistically relevant; however, there was a trend toward more severe notching in the CG group (P = .059). Compared with a CG, an EG did not increase the percentage of radiolucent lines around the screws (3% vs. 1.5%, P = .62), around the post (3% vs. 1.5%, P = .62), or below the baseplate (15% vs. 7.5%, P = .18). CONCLUSION EGs are associated with less notching than CGs. This finding confirms that RSA with an EG is an effective procedure without specific complications at a minimum follow-up of 5 years.
Collapse
Affiliation(s)
- Philippe Collotte
- Centre Orthopédique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, Lyon, France.
| | | | - Thais Dutra Vieira
- Centre Orthopédique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, Lyon, France
| | - Peter Domos
- Royal Free London NHS Foundation Trust, London, UK
| | - Gilles Walch
- Centre Orthopédique Santy, FIFA Medical Centre of Excellence, Groupe Ramsay-Générale de Santé, Hôpital Privé Jean Mermoz, Lyon, France
| |
Collapse
|
27
|
Patel M, Martin JR, Campbell DH, Fernandes RR, Amini MH. Inferior tilt of the glenoid leads to medialization and increases impingement on the scapular neck in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2021; 30:1273-1281. [PMID: 33069903 DOI: 10.1016/j.jse.2020.09.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/15/2020] [Accepted: 09/21/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND In reverse shoulder arthroplasty, Inferior tilt was originally promoted to decrease rates of baseplate failure. However, the literature is conflicting regarding the effect of tilt on scapular neck impingement, which has been associated with an increased risk of notching, increased risk of impingement-related instability, and decreased range of motion. We hypothesized that inferior tilt of -10° would lead to increased medialization and increased scapular neck impingement compared with 0° of tilt. METHODS Twenty patients without glenoid bone loss undergoing reverse shoulder arthroplasty (RSA) at a single institution underwent computed tomography scans of the entire scapula and proximal humerus for preoperative planning. For each patient, we digitally implanted a 25-mm glenoid baseplate flush with the inferior rim of the glenoid. We then simulated impingement-free range of motion with 16 different implant configurations: glenoid tilt (0° vs. -10°), baseplate lateralization (0 mm vs. +6 mm), glenosphere size (36 mm vs. 42 mm), and neck-shaft angle (135° vs. 145°). The primary endpoint was external rotation with the arm at the side (ERS), which is the primary mode of both notching and impingement-related instability, and the secondary endpoint was adduction (ADD). We recorded the RSA angle, preoperative scapular neck length (SNL), and postoperative SNL. Data were compared by paired t tests and a multivariable regression analysis. RESULTS In every simulation, inferior tilt led to more impingement on the scapular neck. Inferior tilt of the glenoid component was associated with a mean 27% decrease in impingement-free external rotation (P < .01 in all cases) and a mean 32% decrease in impingement-free ADD (P < .01 in all cases). Inferior tilt removed 3.2 mm of additional SNL (P < .001). Multivariable regression analysis showed that lateralization had the most impact on impingement-free external rotation and ADD (P < .001), followed by glenosphere size (P < .001), neck-shaft angle (P < .001), postoperative SNL (P < .001), glenoid tilt (P = .001), inclination (P < .001), and RSA angle (P = .023 for ERS and P = .025 for ADD). CONCLUSION Relative to 0° of tilt of the baseplate, inferior tilt of -10° was associated with increased scapular neck impingement in ERS and ADD, likely a result of the increased medialization necessary to seat an inferiorly tilted implant, which shortens the scapular neck and brings the humerus closer to the scapula. This scapular neck impingement increases the risk of notching and impingement-related instability.
Collapse
Affiliation(s)
- Midhat Patel
- Department of Orthopaedic Surgery, University of Arizona College of Medicine, Phoenix, AZ, USA
| | - John R Martin
- Department of Orthopaedic Surgery, University of Arizona College of Medicine, Phoenix, AZ, USA
| | - David H Campbell
- Department of Orthopaedic Surgery, University of Arizona College of Medicine, Phoenix, AZ, USA
| | | | | |
Collapse
|
28
|
Holschen M, Kiriazis A, Bockmann B, Schulte TL, Witt KA, Steinbeck J. Treating cuff tear arthropathy by reverse total shoulder arthroplasty: do the inclination of the humeral component and the lateral offset of the glenosphere influence the clinical and the radiological outcome? EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:307-315. [PMID: 33880654 DOI: 10.1007/s00590-021-02976-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Accepted: 04/12/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE Reverse total shoulder arthroplasty is widely used for the treatment of cuff tear arthropathy. Standard implants consist of a humeral component with an inclination angle of 155° and a glenosphere without lateral offset. Recently, lower inclination angles of the humeral component as well as lateralized glenospheres are implanted to provide better rotation of the arm and to decrease the rate of scapular notching. This study investigates the clinical and radiological results of a standard reverse total shoulder in comparison with an implant with an inclination angle of 135° in combination with a 4 mm lateralized glenosphere in context of cuff tear arthropathy. MATERIAL AND METHODS For this retrospective comparative analysis 42 patients treated by reverse total shoulder arthroplasty for cuff tear arthropathy were included. Twenty-one patients (m = 11, f = 10; mean age 76 years; mean follow-up 42 months) were treated with a standard 155° humeral component and a standard glenosphere with caudal eccentricity (group A), while twenty-one patients (m = 5, f = 16; mean age 72 years; mean follow-up 34 months) were treated with a 135° humeral component and 4 mm lateral offset of the glenosphere (group B). At follow-up patients of both groups were assessed with plain X-rays (a.p. and axial view), Constant Score, adjusted Constant Score, the subjective shoulder value and the range of motion. RESULTS The clinical results were similar in both groups concerning the Constant Score (group A = 56.3 vs. group B = 56.1; p = 0.733), the adjusted CS (group A = 70.4% vs. group B = 68.3%; p = 0.589) and the SSV (group A = 72.0% vs. group B = 75.2%; p = 0.947). The range of motion of the operated shoulders did not differ significantly between group A and group B: Abduction = 98° versus 97.9°, p = 0.655; external rotation with the arm at side = 17.9° versus 18.7°, p = 0.703; external rotation with the arm positioned in 90° of abduction = 22.3° versus 24.7°, p = 0.524; forward flexion = 116.1° versus 116.7°, p = 0.760. The rate of scapular notching was higher (p = 0.013) in group A (overall: 66%, grade 1: 29%, grade 2: 29%, grade 3: 10%, grade 4: 0%) in comparison to group B (overall: 33%, grade 1: 33%, grade 2: 0%, grade 3: 0%, grade 4: 0%). Radiolucency around the humeral component was detected in two patients of group B. Stress shielding at the proximal humerus was observed in six patients of Group A (29%; cortical thinning and osteopenia in zone M1 and L1) and two patients of group B (10%; cortical thinning and osteopenia in zone M1 and L1). Calcifications of the triceps origin were observed in both groups (group A = 48% vs. group B = 38%). CONCLUSION Theoretically, a lower inclination angle of the humeral component and an increased lateral offset of the glenosphere lead to improved impingement-free range of motion and a decreased rate of scapular notching, when compared to a standard reverse total shoulder implant. This study compared two different designs of numerous options concerning the humeral component and the glenosphere. In comparison to a standard-fashioned implant with a humeral inclination of 155° and a standard glenosphere, implants with a humeral inclination angle of 135° and a 4 mm lateralized glenosphere lead to comparable clinical results and rotatory function, while the rate of scapular notching is decreased by almost 50%. While the different implant designs did not affect the clinical outcome, our results indicate that a combination of a lower inclination angle of the humeral component and lateralized glenosphere should be favored to reduce scapular notching. LEVEL OF EVIDENCE Level III, retrospective comparative study.
Collapse
Affiliation(s)
- Malte Holschen
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany. .,Raphaelsklinik, Münster, Germany.
| | | | - Benjamin Bockmann
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Tobias L Schulte
- Department of Orthopedics and Trauma Surgery, St. Josef Hospital, Ruhr-University Bochum, Bochum, Germany
| | - Kai-Axel Witt
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany
| | - Jörn Steinbeck
- Orthopedic Practice Clinic (OPPK), Schuerbusch 55, 48143, Münster, Germany
| |
Collapse
|
29
|
Factors Influencing Appropriate Implant Selection and Position in Reverse Total Shoulder Arthroplasty. Orthop Clin North Am 2021; 52:157-166. [PMID: 33752837 DOI: 10.1016/j.ocl.2020.12.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Reverse shoulder arthroplasty has increased in popularity and has provided improved but somewhat variable results. These variable outcomes may be related to many factors, including implant design, component positioning, specific indication, and patient anatomy. The original Grammont design provided a solution to the high failure rate at the time but was found to have a high rate of scapular notching and poor restoration of rotation. Modern lateralized designs are more consistent in reducing scapular notching while improving range of motion, especially in regards to external rotation. This review article summarizes the effects of modern reverse shoulder prostheses on outcomes.
Collapse
|
30
|
Impact of humeral and glenoid component variations on range of motion in reverse geometry total shoulder arthroplasty: a standardized computer model study. J Shoulder Elbow Surg 2021; 30:763-771. [PMID: 32763384 DOI: 10.1016/j.jse.2020.07.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 07/13/2020] [Accepted: 07/19/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Multiple modifications of reverse total shoulder arthroplasty (RTSA) since the first Grammont design have developed to improve range of motion (ROM) and avoid notching. The effect of these changes in shoulder kinematics and the best compromise for ROM is still under debate. This computer simulation study evaluates the influence of humeral design, humeral neck-shaft angle (NSA), glenoid lateralization, and glenoid eccentricity on ROM of RTSA. METHODS We created a 3-dimensional computer model from computed tomography scans of 13 patients with primary osteoarthritis simulating implantation of a standardized reverse shoulder arthroplasty. We analyzed the effect of 4 different variables on impingement-free ROM: humeral design (inlay vs. semi-inlay vs. onlay), humeral NSA (135° vs. 145° vs. 155°), glenoid lateralization, and glenoid eccentricity on ROM. RESULTS The use of different humeral stem designs did not have a significant effect on total global ROM. Reducing NSA demonstrated a significant increase in adduction, and external and internal rotation in adduction, whereas a decrease in abduction and external rotation in abduction. Glenosphere lateralization was the most effective method for increasing total global ROM (P < .0001); however, extreme lateralization (+12 mm) did not show significant benefit compared with moderate lateralization (+4 mm). Glenosphere eccentricity increased only adduction and internal rotation in adduction. CONCLUSION Only glenoid lateralization has a significant effect on increasing total global ROM in RTSA. The use of the semi-inlay 145° model combined with 4 mm lateralization and 2 mm inferior eccentricity represents the middle ground and the most universal approach in RTSA.
Collapse
|
31
|
Dimock R, Fathi Elabd M, Imam M, Middleton M, Godenèche A, Narvani AA. Bony increased-offset reverse shoulder arthroplasty: A meta-analysis of the available evidence. Shoulder Elbow 2021; 13:18-27. [PMID: 33717215 PMCID: PMC7905510 DOI: 10.1177/1758573220916848] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 03/05/2020] [Accepted: 03/10/2020] [Indexed: 11/16/2022]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) has revolutionized the management of many shoulder pathologies. Lateralization has become favourable to combat complications (e.g. notching, compromised external rotation), using a metallic, or autogenous bone-graft baseplates - bony increased-offset reverse shoulder arthroplasty (BIO-RSA). We systematically reviewed the literature to determine: Does BIO-RSA improve range of motion and outcome scores?Are notching rates decreased?Does the graft heal? METHODS All available prospective studies, trials and case series reporting on BIO-RSA were included. Outcomes were grouped into outcome scores, range of motion and radiographic outcomes. Data were pooled and statistical analysis performed. RESULTS Eight studies reported on 385 RSA - 235 BIO-RSA and 150 standard-RSA (STD-RSA). Follow-up was 20-36 months; average age 74 years. Outcome scores: Constant-Murley and SSV scores showed statistically significant post-operative benefit of BIO-RSA (mean-difference 4.0 (95% confidence interval (CI): 0.79,7.1) and 6.8 (95% CI: 3.8, 9.9)). No Minimal Clinically Importance Difference was surpassed. Range of motion: No difference was found in any direction. Notching: Notching was less likely with BIO-RSA (odds ratio 0.19 (95% CI: 0.10, 0.38)). Healing and loosening: 92% grafts fully healed/incorporated. Loosening rate was 2.4%. CONCLUSIONS Literature on BIO-RSA is limited with only one randomised controlled trial (RCT). Weak evidence exists for improved outcome scores. Range of motion is equivocal. Notching rates are significantly lower in BIO-RSA. The graft usually heals.
Collapse
Affiliation(s)
- Richard Dimock
- Rowley Bristow Unit, Ashford &
St Peters NHS FT, Surrey, UK
| | | | - Mohamed Imam
- Rowley Bristow Unit, Ashford &
St Peters NHS FT, Surrey, UK,University of East Anglia, Norwich,
UK
| | - Mark Middleton
- Rowley Bristow Unit, Ashford &
St Peters NHS FT, Surrey, UK
| | | | - A Ali Narvani
- Rowley Bristow Unit, Ashford &
St Peters NHS FT, Surrey, UK,Fortius Clinic, London, UK,A Ali Narvani, Fortius Clinic, 17
Fitzhardinge Street, London W1H 6EQ, UK.
| |
Collapse
|
32
|
Huish EG, Athwal GS, Neyton L, Walch G. Adjusting Implant Size and Position Can Improve Internal Rotation After Reverse Total Shoulder Arthroplasty in a Three-dimensional Computational Model. Clin Orthop Relat Res 2021; 479:198-204. [PMID: 33044311 PMCID: PMC7899712 DOI: 10.1097/corr.0000000000001526] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 09/16/2020] [Indexed: 01/31/2023]
Abstract
BACKGROUND Efforts during reverse total shoulder arthroplasty (RSA) have typically focused on maximizing ROM in elevation and external rotation and avoiding scapular notching. Improving internal rotation (IR) is often overlooked, despite its importance for functional outcomes in terms of patient self-care and hygiene. Although determinants of IR are multifactorial, it is unable to surpass limits of bony impingement of the implant. Identifying implant configurations that can reduce bony impingement in a computer model will help surgeons during preoperative planning and also direct implant design and clinical research going forward. QUESTIONS/PURPOSES In a CT-modeling study, we asked: What reverse total shoulder arthroplasty implant position improves the range of impingement free internal rotation without compromising other motions (external rotation and extension)? METHODS CT images stored in a deidentified teaching database from 25 consecutive patients with Walch A1 glenoids underwent three-dimensional templating for RSA. Each template used the same implant and configuration, which consisted of an onlay humeral design and a 36-mm standard glenosphere. The resulting constructs were virtually taken through ROM until bony impingement was found. Variations were made in the RSA parameters of baseplate lateralization, glenosphere size, glenosphere overhang, humeral version, and humeral neck-shaft angle. Simulated ROM was repeated after each parameter was changed individually and then again after combining multiple changes into a single configuration. The impingement-free IR was calculated and compared between groups. We also evaluated the effect on other ROM including external rotation and extension to ensure that configurations with improvements in IR were not associated with losses in other areas. RESULTS Combining lateralization, inferiorization, varus neck-shaft angle, increased glenosphere size, and increased humeral anteversion resulted in a greater improvement in internal rotation than any single parameter change did (median baseline IR: 85° [interquartile range 73° to 90°]; combined changes: 119° [IQR 113° to 121°], median difference: 37° [IQR 32° to 43°]; p < 0.001). CONCLUSION Increased glenosphere overhang, varus neck-shaft angle, and humeral anteversion improved internal rotation in a computational model, while glenoid lateralization alone did not. Combining these techniques led to the greatest improvement in IR. CLINICAL RELEVANCE This computer model study showed that various implant changes including inferiorization, varus neck-shaft angle, increased glenosphere size, and increased humeral anteversion can be combined to increase impingement-free IR. Surgeons can employ these currently available implant configurations to improve IR when planning and performing RSA. These findings support the need for further clinical studies validating the effect of implant configuration on resultant IR.
Collapse
Affiliation(s)
- Eric G Huish
- E. G. Huish, L. Neyton, G. Walch, Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
- E. G. Huish, Department of Orthopaedic Surgery, San Joaquin General Hospital, French Camp, CA, USA
- G. S. Athwal, St. Joseph's Health Care, Hand and Upper Limb Centre, University of Western Ontario, Western University, London, ON, Canada
| | - George S Athwal
- E. G. Huish, L. Neyton, G. Walch, Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
- E. G. Huish, Department of Orthopaedic Surgery, San Joaquin General Hospital, French Camp, CA, USA
- G. S. Athwal, St. Joseph's Health Care, Hand and Upper Limb Centre, University of Western Ontario, Western University, London, ON, Canada
| | - Lionel Neyton
- E. G. Huish, L. Neyton, G. Walch, Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
- E. G. Huish, Department of Orthopaedic Surgery, San Joaquin General Hospital, French Camp, CA, USA
- G. S. Athwal, St. Joseph's Health Care, Hand and Upper Limb Centre, University of Western Ontario, Western University, London, ON, Canada
| | - Gilles Walch
- E. G. Huish, L. Neyton, G. Walch, Ramsay Générale de Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
- E. G. Huish, Department of Orthopaedic Surgery, San Joaquin General Hospital, French Camp, CA, USA
- G. S. Athwal, St. Joseph's Health Care, Hand and Upper Limb Centre, University of Western Ontario, Western University, London, ON, Canada
| |
Collapse
|
33
|
The influence of posture and scapulothoracic orientation on the choice of humeral component retrotorsion in reverse total shoulder arthroplasty. J Shoulder Elbow Surg 2020; 29:1992-2001. [PMID: 32327269 DOI: 10.1016/j.jse.2020.01.089] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2019] [Revised: 01/16/2020] [Accepted: 01/21/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The literature suggests implantation of the humeral component in reverse total shoulder arthroplasty (RTSA) in 0°-40° of retrotorsion without further specification. We hypothesized that optimal humeral component retrotorsion to avoid notching and gain balanced rotational capacity would depend on scapular position and posture. METHODS We investigated 200 shoulders in 100 patients with available whole-body computed tomography scans and created 3-dimensional models. Implantation of a humeral component in 20° of retrotorsion was simulated, and a correction angle (CA) to yield perfect opposition to the glenosphere was calculated. Patient-specific variables such as age, sex, posture, and scapular orientation parameters were correlated with this CA. RESULTS Scapular orientation showed large interindividual differences. A highly significant correlation was seen between the CA and scapular internal rotation (R = 0.71, P < .001) and protraction (R = 0.39, P < .001). When the CA was adjusted for glenoid retroversion, the correlation coefficient of scapular internal rotation increased even further (R = 0.91, P < .001). Scapular internal rotation itself showed a correlation with thoracic kyphosis (R = 0.27, P < .001), protraction (R = 0.57, P < .001), tilt (R = 0.29, P < .001), and scapular translation (R = -0.23, P < .001). CONCLUSION Scapular orientation and posture should be integrated into the determination process of humeral component retrotorsion in RTSA. In theory, implantation of the humeral component with increased retrotorsion leads to improved neutral opposition of the RTSA components in patients with extensive internal rotation of the scapula. On the basis of varying scapular internal rotation, we propose the distinction of 3 different posture types (A-C) for enhanced appraisal of scapulothoracic orientation.
Collapse
|
34
|
O'Sullivan J, Lädermann A, Parsons BO, Werner B, Steinbeck J, Tokish JM, Denard PJ. A systematic review of tuberosity healing and outcomes following reverse shoulder arthroplasty for fracture according to humeral inclination of the prosthesis. J Shoulder Elbow Surg 2020; 29:1938-1949. [PMID: 32815808 DOI: 10.1016/j.jse.2020.03.032] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 03/21/2020] [Accepted: 03/26/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Proximal humerus fractures are common in the elderly population and are often treated with reverse shoulder arthroplasty (RSA). The purpose of this systematic review was to compare tuberosity healing and functional outcomes in patients undergoing RSA with humeral inclinations of 135°, 145°, and 155°. METHODS A systematic review was performed of RSA for proximal humerus fracture using Preferred Reporting Items for Systemic Reviews and Meta-Analyses (PRISMA) guidelines. Radiographic and functional outcome data were extracted to evaluate tuberosity healing according to humeral inclination. Analysis was also performed of healed vs. nonhealed tuberosities. RESULTS A total of 873 patients in 21 studies were included in the analysis. The mean age was 77.5 years (range of 58-97) and the mean follow-up was 26.2 months. Tuberosity healing was 83% in the 135° group compared with 69% in the 145° group and 66% in the 155° group (P = .030). Postoperative abduction was highest in the 155° group (P < .001). No significant difference was found in forward flexion, external rotation, or postoperative Constant score between groups. Patients with tuberosity healing demonstrated 18° higher forward flexion (P = .008) and 16° greater external rotation (P < .001) than those with unhealed tuberosities. CONCLUSION RSA for fracture with 135° humeral inclination is associated with higher tuberosity healing rates compared with 145° or 155°. Postoperative abduction is highest with a 155° implant, but there is no difference in in postoperative forward flexion, external rotation, or Constant score according to humeral inclination. Patients with healed tuberosities have superior postoperative forward flexion and external rotation than those with unhealed tuberosities.
Collapse
Affiliation(s)
- Joseph O'Sullivan
- Department of Orthopaedics and Rehabilitation, Oregon Health and Science University, Portland, OR, USA
| | - Alexandre Lädermann
- Division of Orthopedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | - Bradford O Parsons
- Department of Orthopedics, Mount Sinai Medical Center, New York, NY, USA
| | - Brian Werner
- Department of Orthopedics, University of Virginia, Charlottesville, VA, USA
| | | | - John M Tokish
- Department of Orthopedics, Mayo Clinic, Scottsdale, AZ, USA
| | - Patrick J Denard
- Southern Oregon Orthopedics, Medford, OR, USA; Department of Orthopaedic & Rehabilitation, Oregon Health & Science University, Portland, OR, USA.
| |
Collapse
|
35
|
Collotte P, Erickson J, Vieira TD, Domos P, Walch G. Midterm clinical and radiologic results of reverse shoulder arthroplasty with an eccentric glenosphere. J Shoulder Elbow Surg 2020; 29:976-981. [PMID: 31911214 DOI: 10.1016/j.jse.2019.09.044] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 09/25/2019] [Accepted: 09/30/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND An eccentric glenosphere (EG) has been proposed as a way of preventing scapular notching after reverse shoulder arthroplasty (RSA). Our aim was to report the midterm clinical and radiographic results of EG after RSA. A number of the patients described here were included in a previous study with short-term follow-up. The current retrospective study gave us the opportunity to follow many of these patients for a longer period of time. METHODS A retrospective analysis of prospectively collected data was conducted. Statistical significance was set at P < .001. Forty-nine RSAs with an EG and at least 60 months of follow-up were included. Range of motion (ROM), Constant scores (CSs), and Subjective Shoulder Value (SSV) were assessed. Scapular notching was graded according to the Sirveaux classification. RESULTS At the last follow-up, the mean improvement in active elevation (ROM) was 46° and the mean CS increased by nearly 31 points (both groups P < .001). The final SSV was 70%. Twenty-one patients (43%) had scapular notching, but in two-thirds of patients it was low-grade. CONCLUSION The use of an EG provided excellent clinical outcomes that persisted with midterm follow-up. The rate of notching was lower than in other studies with EGs, but further studies are required to confirm this. An EG was safe and there were no issues with baseplate loosening or failure.
Collapse
Affiliation(s)
- Philippe Collotte
- Ramsay Générale de Santé, Hôpital privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France.
| | | | - Thais Dutra Vieira
- Ramsay Générale de Santé, Hôpital privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| | - Peter Domos
- The Royal Free London NHS Foundation Trust, London, UK
| | - Gilles Walch
- Ramsay Générale de Santé, Hôpital privé Jean Mermoz, Centre Orthopédique Santy, Lyon, France
| |
Collapse
|
36
|
Lädermann A, Chiu JCH, Cunningham G, Hervé A, Piotton S, Bothorel H, Collin P. Do short stems influence the cervico-diaphyseal angle and the medullary filling after reverse shoulder arthroplasties? Orthop Traumatol Surg Res 2020; 106:241-246. [PMID: 32057747 DOI: 10.1016/j.otsr.2019.12.010] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Revised: 11/29/2019] [Accepted: 12/18/2019] [Indexed: 02/03/2023]
Abstract
BACKGROUND Shorter humeral stems were developed to improve bone preservation, vascularity and osteointegration in reverse total shoulder arthroplasty (RSA). While some studies examined the relationship between canal filling and radiographic changes, none evaluated the association between stem alignment and canal fill ratio (CFR). HYPOTHESIS The hypothesis was that stem misalignment after RSA would be associated with lower CFR. PATIENTS AND METHODS The authors retrospectively reviewed immediate postoperative radiographs of 157 patients, comprising 56 men (36%), who underwent RSA with a short uncemented stem with neck shaft angle (NSA) default of 145°. The parameters included postoperative NSA and metaphyseal CFR, both measured with excellent inter-observer agreement. Uni- and multivariable linear regressions were performed to determine associations between postoperative NSA and 5 variables (CFR, gender, age, BMI, and surgical approach). RESULTS Postoperative NSA was 149°±8°, exceeding 5° of varus in 15 shoulders (9%) and 5° of valgus in 60 shoulders (38%), and CFR was 58%±8%. CFR was lower in shoulders with varus stem alignment (54%±6%) than shoulders with neutral stem alignment (59%±8%, p=0.033). Multivariable regression revealed that postoperative NSA increased with age (beta: 0.20; p=0.008), was higher for shoulders operated with the subscapularis- and deltoid-sparing approach (beta: 3.82; p=0.040) but lower for men (beta: -4.14; p=0.002). CONCLUSIONS Stem misalignment exceeded 5° in 47% of the shoulders. Women, older age, and subscapularis- and deltoid-sparing approach are associated with greater risks of valgus stem positioning, while lower CFR seems to be associated with greater risks of varus stem positioning. LEVEL OF EVIDENCE IV; case series.
Collapse
Affiliation(s)
- Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland; Faculty of Medicine, University of Geneva, Geneva, Switzerland; Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland; Division of Orthopaedics and Trauma Surgery, Hirslanden Clinique La Colline, Geneva, Switzerland
| | - Joe Chih-Hao Chiu
- Department of Orthopaedic Sports Medicine, Chang Gung Memorial Hospital, Taoyuan City, Taiwan
| | - Grégory Cunningham
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland; Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Anthony Hervé
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Sébastien Piotton
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
| | - Hugo Bothorel
- ReSurg SA, Rue Saint-Jean 22, 1260 Nyon, Switzerland.
| | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| |
Collapse
|
37
|
Lädermann A, Denard PJ, Collin P, Zbinden O, Chiu JCH, Boileau P, Olivier F, Walch G. Effect of humeral stem and glenosphere designs on range of motion and muscle length in reverse shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2020; 44:519-530. [PMID: 31900574 DOI: 10.1007/s00264-019-04463-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2019] [Accepted: 12/06/2019] [Indexed: 01/27/2023]
Abstract
PURPOSE To determine how different combinations of humeral stem and glenosphere designs for reverse shoulder arthroplasty (RSA) influence range of motion (ROM) and muscle elongation. METHODS A computed tomography scan of a non-pathologic shoulder was used to simulate all shoulder motions, and thereby compare the ROM and rotator cuff muscle lengths of the native shoulder versus 30 combinations of humeral components (1 inlay straight stem with 155° inclination and five onlay curved stems with 135°, 145° or 155° inclinations, using concentric, medialized or lateralized trays) and glenospheres (standard, large, lateralized, inferior eccentric and bony increased-offset (BIO-RSA)). RESULTS Only five of the 30 combinations restored ≥ 50% of the native ROM in all directions: the 145° onlay stem (concentric tray) combined with lateralized or inferior eccentric glenospheres and the 145° stem (lateralized tray) combined with either a large, lateralized or inferior eccentric glenosphere. Lengthening of the supraspinatus and infraspinatus, observed for all configurations, was greatest using onlay stems (7-30%) and BIO-RSA glenospheres (13-31%). Subscapularis lengthening was observed for onlay stems combined with BIO-RSA glenospheres (5-9%), while excessive subscapularis shortening was observed for the inlay stem combined with all glenospheres except the BIO-RSA design (> 15%). CONCLUSIONS The authors suggest implanting 145° onlay stems, with concentric or lateralized trays, together with lateralized or inferior eccentric glenospheres.
Collapse
Affiliation(s)
- Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
- Division of Orthopaedics and Trauma Surgery, Hirslanden Clinique La Colline, Geneva, Switzerland
| | - Patrick J Denard
- Southern Oregon Orthopedics, Medford, OR, USA
- Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, OR, USA
| | - Philippe Collin
- Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Olivia Zbinden
- Service of Orthopedics and Traumatology, Lausanne University Hospital, Lausanne, Switzerland
| | - Joe Chih-Hao Chiu
- Department of Orthopaedic Sports Medicine, Chang Gung Memorial Hospital, Taoyuan City, Taiwan
| | - Pascal Boileau
- iULS (Institut Universitaire Locomoteur et du Sport), Hôpital Pasteur 2, University Côte d'Azur, Nice, France
| | - Flora Olivier
- ReSurg SA, Rue Saint-Jean 22, 1260, Nyon, Switzerland.
| | - Gilles Walch
- Centre Orthopédique Santy, Hôpital Privé Jean Mermoz Ramsay GDS, Lyon, France
| |
Collapse
|
38
|
Torrens C, Miquel J, Martínez R, Santana F. Can small glenospheres with eccentricity reduce scapular notching as effectively as large glenospheres without eccentricity? A prospective randomized study. J Shoulder Elbow Surg 2020; 29:217-224. [PMID: 31784386 DOI: 10.1016/j.jse.2019.09.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2019] [Revised: 09/11/2019] [Accepted: 09/12/2019] [Indexed: 02/01/2023]
Abstract
BACKGROUND The objective of this study was to analyze whether small glenospheres with eccentricity were comparable to large glenospheres in scapular notch development. METHODS This prospective randomized study included 82 patients who had undergone a reverse shoulder arthroplasty with a 2-year follow-up period. After randomization, 43 patients were allocated to receive a 42-mm glenosphere and 39 patients were allocated to receive a 38-mm glenosphere with 2 mm of eccentricity. Scapular notch development was defined after examination of an anteroposterior radiograph at the end of follow-up. Functional outcomes were recorded using the Constant score before surgery and at the end of follow-up. RESULTS Scapular notch development was present in 16.6% of patients who received a 42-mm glenosphere and 34.2% of patients who received a 38-mm eccentric glenosphere. No significant difference was found between the groups with the number of cases available (P = .07). Functional outcomes significantly increased from preoperatively to postoperatively in both groups, with no significant difference found between them (P = .77). The mean glenosphere overhang measure was 6.3 mm in patients with a 42-mm glenosphere and 6.0 mm in those with a 38-mm eccentric glenosphere (P = .68). No significant differences were noted between patients with a scapular notch and patients without a scapular notch in terms of functional outcomes. DISCUSSION Small glenospheres with eccentricity fared slightly worse than large glenospheres regarding scapular notch development, even though no significant differences were noted. Functional outcomes were comparable between the 2 designs.
Collapse
Affiliation(s)
- Carlos Torrens
- Department of Orthopedics, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain.
| | - Joan Miquel
- Department of Orthopedics, Hospital d'Igualada, Consorci Sanitari de l'Anoia, Barcelona, Spain
| | - Raquel Martínez
- Department of Orthopedics, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain
| | - Fernando Santana
- Department of Orthopedics, Hospital del Mar, Parc de Salut Mar, Barcelona, Spain
| |
Collapse
|
39
|
Rol M, Favard L, Berhouet J. Factors associated with internal rotation outcomes after reverse shoulder arthroplasty. Orthop Traumatol Surg Res 2019; 105:1515-1519. [PMID: 31680017 DOI: 10.1016/j.otsr.2019.07.024] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 06/11/2019] [Accepted: 07/19/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND Reverse shoulder arthroplasty (RSA) was introduced in 1985 by Grammont for patients with gleno-humeral osteoarthritis and severe rotator cuff damage. Internal rotation (IR) is limited in some patients after RSA. The objective of this study was to identify pre- and intra-operative factors associated with good IR outcomes 6 months after RSA. HYPOTHESIS The condition of the residual cuff (usually the sub-scapularis and teres minor) and inferior glenosphere overhang are the main factors associated with IR outcomes after RSA. MATERIAL AND METHOD A total of 36 patients who underwent RSA between 2 November 2015 and 10 January 2017 were enrolled prospectively. The inclusion criterion was massive rotator cuff tear with or without osteoarthritis and gleno-humeral osteoarthritis with asymmetrical glenoid wear. The pre-operative work-up included determination of the Constant score, Subjective Shoulder Value (SSV), and passive and active motion ranges; standard radiographs; and computed tomography. The same clinical and radiological parameters were recorded in all patients during a visit 6 months after surgery. RESULTS After surgery, all motion ranges were improved except IR with the elbow by the side (IR1, ability to place the hand on the back). IR1 to or above L3 was significantly associated with a lower body mass index (p=0.04), good passive IR before surgery (p=0.056), a smaller pre-operative glenoid inclination angle, and greater glenosphere overhang (p=0.03). Neither the condition of the sub-scapularis nor sub-scapularis repair were significantly associated with post-operative IR1. IR1 was significantly more limited in patients whose teres minor was normal. CONCLUSION Satisfactory active IR1 correlated with good passive IR1. IR1 was better in thin individuals who had non-concentric gleno-humeral osteoarthritis. Inferior glenosphere overhang of 6mm or more was associated with a greater range of IR. LEVEL OF EVIDENCE IV, prospective observational cohort study.
Collapse
Affiliation(s)
- Morgane Rol
- Service d'orthopédie traumatologie, Université François-Rabelais-de-Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-les-Tours, France.
| | - Luc Favard
- Service d'orthopédie traumatologie, Université François-Rabelais-de-Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-les-Tours, France
| | - Julien Berhouet
- Service d'orthopédie traumatologie, Université François-Rabelais-de-Tours, CHRU Trousseau, avenue de la République, 37170 Chambray-les-Tours, France
| |
Collapse
|
40
|
Boileau P, Gauci MO, Wagner ER, Clowez G, Chaoui J, Chelli M, Walch G. The reverse shoulder arthroplasty angle: a new measurement of glenoid inclination for reverse shoulder arthroplasty. J Shoulder Elbow Surg 2019; 28:1281-1290. [PMID: 30935825 DOI: 10.1016/j.jse.2018.11.074] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Revised: 11/26/2018] [Accepted: 11/30/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Avoiding superior inclination of the glenoid component in reverse shoulder arthroplasty (RSA) is crucial. We hypothesized that superior inclination was underestimated in RSA. Our purpose was to describe and assess a new measurement of inclination for the inferior portion of the glenoid (where the baseplate rests). METHODS The study included 47 shoulders with rotator cuff tear arthropathy (mean age, 76 years). The reverse shoulder arthroplasty angle (RSA angle), defined as the angle between the inferior part of the glenoid fossa and the perpendicular to the floor of the supraspinatus, was compared with the global glenoid inclination (β angle or total shoulder arthroplasty [TSA] angle). Measurements were made on plain anteroposterior radiographs and reformatted 2-dimensional (2D) computed tomography (CT) scans by 3 independent observers and compared with 3-dimensional (3D) software (Glenosys) measurements. RESULTS The mean RSA angle was 25° ± 8° on plain radiographs, 20° ± 6° on reformatted 2D CT scans, and 21° ± 5° via 3D reconstruction software. The mean TSA angle was on average 10° ± 5° lower than the mean RSA angle (P < .001); this difference was observed regardless of the method of measurement (radiographs, 2D CT, or 3D CT) and type of glenoid erosion according to Favard. In Favard type E1 glenoids with central concentric erosion, the difference between the 2 angles was 12° ± 4° (P < .001). CONCLUSION The same angle cannot be used to measure glenoid inclination in anatomic and reverse prostheses. The TSA (or β) angle underestimates the superior orientation of the reverse baseplate in RSA. The RSA angle (20° ± 5°) needs to be corrected to achieve neutral inclination of the baseplate (RSA angle = 0°). Surgeons should be aware that E1 glenoids (with central erosion) are at risk for baseplate superior tilt if the RSA angle is not corrected.
Collapse
Affiliation(s)
- Pascal Boileau
- University Institute of Locomotion & Sport (iULS), Pasteur 2 Hospital, University of Nice-Sophia Antipolis, Nice, France.
| | - Marc-Olivier Gauci
- University Institute of Locomotion & Sport (iULS), Pasteur 2 Hospital, University of Nice-Sophia Antipolis, Nice, France
| | - Eric R Wagner
- Division of Upper Extremity Surgery, Department of Orthopaedic Surgery, Emory University, Atlanta, GA, USA
| | - Gilles Clowez
- University Institute of Locomotion & Sport (iULS), Pasteur 2 Hospital, University of Nice-Sophia Antipolis, Nice, France
| | | | - Mikaël Chelli
- University Institute of Locomotion & Sport (iULS), Pasteur 2 Hospital, University of Nice-Sophia Antipolis, Nice, France
| | | |
Collapse
|
41
|
Werner BS, Chaoui J, Walch G. Glenosphere design affects range of movement and risk of friction-type scapular impingement in reverse shoulder arthroplasty. Bone Joint J 2018; 100-B:1182-1186. [DOI: 10.1302/0301-620x.100b9.bjj-2018-0264.r1] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims Scapular notching is a frequently observed radiographic phenomenon in reverse shoulder arthroplasty (RSA), signifying impingement of components. The purposes of this study were to evaluate the effect of glenoid component size and glenosphere type on impingement-free range of movement (ROM) for extension and internal and external rotation in a virtual RSA model, and to determine the optimal configuration to reduce the incidence of friction-type scapular notching. Materials and Methods Preoperative CT scans obtained in 21 patients (three male, 18 female) with primary osteoarthritis were analyzed using modelling software. Two concurrent factors were tested for impingement-free ROM and translation of the centre of rotation: glenosphere diameter (36 mm vs 39 mm) and type (centred, 2 mm inferior eccentric offset, 10° inferior tilt). Results Glenosphere size was most predictive of increased extension and external rotation, whereas lateralization of the centre of rotation was the most predictive factor for internal rotation. A larger diameter of glenosphere combined with a 10° tilted configuration demonstrated superior values for extension and external rotation, whereas the eccentric component improved internal rotation by a mean 8.9° (standard deviation 2.7°) compared with a standard concentric glenosphere. Conclusion Glenosphere configuration can be modified to increase range of movement in RSA. Friction-type scapular notching was most effectively reduced by use of a large-diameter glenosphere with 10° inferior tilt. Cite this article: Bone Joint J 2018;100-B:1182–6.
Collapse
Affiliation(s)
- B. S. Werner
- Clinic for Shoulder and Elbow Surgery, Bad
Neustadt an der Saale, Germany
| | | | - G. Walch
- Centre Orthopédique Santy, Hôpital Jean
Mermoz, Lyon, France
| |
Collapse
|
42
|
Kolmodin J, Davidson IU, Jun BJ, Sodhi N, Subhas N, Patterson TE, Li ZM, Iannotti JP, Ricchetti ET. Scapular Notching After Reverse Total Shoulder Arthroplasty: Prediction Using Patient-Specific Osseous Anatomy, Implant Location, and Shoulder Motion. J Bone Joint Surg Am 2018; 100:1095-1103. [PMID: 29975263 DOI: 10.2106/jbjs.17.00242] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Scapular notching is frequently observed following reverse total shoulder arthroplasty (rTSA), although the etiology is not well understood. METHODS Twenty-nine patients with preoperative computed tomography (CT) scans who underwent rTSA with a Grammont design were evaluated after a minimum of 2 years of follow-up with video motion analysis (VMA), postoperative three-dimensional (3D) CT, and standard radiographs. The glenohumeral range of motion demonstrated by the VMA and the postoperative implant location on the CT were used in custom simulation software to determine areas of osseous impingement between the humeral implant and the scapula and their relationship to scapular notching on postoperative CT. Patients with and without notching were compared with one another by univariable and multivariable analyses to determine factors associated with notching. RESULTS Seventeen patients (59%) had scapular notching, which was along the posteroinferior aspect of the scapular neck in all of them and along the anteroinferior aspect of the neck in 3 of them. Osseous impingement occurred in external rotation with the arm at the side in 16 of the 17 patients, in internal rotation with the arm at the side in 3, and in adduction in 12. The remaining 12 patients did not have notching or osseous impingement. Placing the glenosphere in a position that was more inferior (by a mean of 3.4 ± 2.3 mm) or lateral (by a mean of 6.2 ± 1.4 mm) would have avoided most impingement in the patients' given range of motion. Notching was associated with glenosphere placement that was insufficiently inferior (mean inferior translation, -0.3 ± 3.4 mm in the notching group versus 3.0 ± 2.9 mm in the no-notching group; p = 0.01) or posterior (mean, -0.3 ± 3.5 mm versus 4.2 ± 2.2 mm; p < 0.001). Two-variable models showed inferior and posterior (area under the curve [AUC], 0.887; p < 0.001), inferior and lateral (AUC, 0.892; p < 0.001), and posterior and lateral (AUC, 0.892; p < 0.001) glenosphere positions to be significant predictors of the ability to avoid scapular notching. CONCLUSIONS Osseous impingement identified using patients' actual postoperative range of motion and implant position matched the location of scapular notching seen radiographically. Inferior, lateral, and posterior glenosphere positions are all important factors in the ability to avoid notching. Only small changes in implant position were needed to avoid impingement, suggesting that preoperative determination of the ideal implant position may be a helpful surgical planning tool to avoid notching when using this implant design. LEVEL OF EVIDENCE Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Joel Kolmodin
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Iyooh U Davidson
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Bong Jae Jun
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Nipun Sodhi
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Naveen Subhas
- Imaging Institute, Cleveland Clinic, Cleveland, Ohio
| | - Thomas E Patterson
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Zong-Ming Li
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Joseph P Iannotti
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| | - Eric T Ricchetti
- Department of Orthopaedic Surgery, Orthopaedic and Rheumatologic Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
43
|
Lädermann A, Denard PJ, Boileau P, Farron A, Deransart P, Walch G. What is the best glenoid configuration in onlay reverse shoulder arthroplasty? INTERNATIONAL ORTHOPAEDICS 2018; 42:1339-1346. [DOI: 10.1007/s00264-018-3850-x] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2017] [Accepted: 02/15/2018] [Indexed: 10/17/2022]
|
44
|
Lädermann A, Tay E, Scheibel M. Subscapularis-On Approach in Reverse Shoulder Arthroplasty. J Shoulder Elb Arthroplast 2018. [DOI: 10.1177/2471549218808818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Using a subscapularis- and deltoid-preserving anterior approach is an option for patients undergoing reverse shoulder arthroplasty. Outcomes are better at short term than compared with the standard deltopectoral approach. Maintaining the integrity of the subscapularis tendon and preserving the deltoid muscle minimizes the need for postoperative immobilization and rehabilitation, allowing the patient to achieve active shoulder range of motion more rapidly, without increasing the incidence of shoulder dislocation. Overall length of hospital stay and duration of postoperative physical therapy are minimized, leading to significant economic gain. Future studies with longer follow-up are required to document the potential long-term benefits of this surgical technique. Level of Evidence of the study: Review, Level IV
Collapse
Affiliation(s)
- Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Faculty of Medicine, University of Geneva, Geneva, Switzerland
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Eileen Tay
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland
- Department of Orthopaedic Surgery, Ng Teng Fong General Hospital, Singapore, Singapore
| | - Markus Scheibel
- Center for Musculoskeletal Surgery, Campus Virchow, Charité-Universitaetsmedizin Berlin, Berlin, Germany
| |
Collapse
|
45
|
Collin P, Liu X, Denard PJ, Gain S, Nowak A, Lädermann A. Standard versus bony increased-offset reverse shoulder arthroplasty: a retrospective comparative cohort study. J Shoulder Elbow Surg 2018; 27:59-64. [PMID: 28969891 DOI: 10.1016/j.jse.2017.07.020] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/11/2017] [Accepted: 07/14/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND To date, only a few comparative studies with small sample sizes have compared a traditional reverse shoulder arthroplasty (tRSA) to a bony increased-offset RSA (BIO-RSA). We hypothesized that the BIO-RSA would lead to lower notching rates and improved range of motion (ROM) compared with a tRSA. METHODS A retrospective review was performed of 69 tRSAs and 61 BIO-RSAs performed by a single surgeon. At 2 years postoperative, ROM and Constant scores were compared. Radiographs were examined for scapular notching, scapular spurring or ossification, and graft healing. RESULTS At the 2-year follow-up, the BIO-RSA group demonstrated improved anterior forward flexion compared with the tRSA group (145° ± 20° vs. 138° ± 20°, respectively; P = .017). There was no difference in external or internal rotation between the 2 groups. The BIO-RSA group had a higher Constant score than the tRSA group (69 ± 9 vs. 61 ± 13; P < .001). The radiographs showed no difference between the 2 groups, including scapular notching (P = .150). CONCLUSION At the 2-year follow-up, BIO-RSA does not lead to a clinically significantly improvement in ROM, Constant scores, or change in scapular notching compared with a tRSA.
Collapse
Affiliation(s)
- Philippe Collin
- Division of Orthopaedics and Trauma Surgery, Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Xin Liu
- Sports Medicine Service, Beijing Jishuitan Hospital, Beijing, China
| | - Patrick J Denard
- Southern Oregon Orthopedics, Medford, OR, USA; Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, OR, USA
| | - Soleen Gain
- Division of Orthopaedics and Trauma Surgery, Centre Hospitalier Privé Saint-Grégoire (Vivalto Santé), Saint-Grégoire, France
| | - Alexandra Nowak
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland; Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Meyrin, Switzerland; Faculty of Medicine, University of Geneva, Geneva, Switzerland; Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Geneva, Switzerland.
| |
Collapse
|
46
|
Reverse Shoulder Arthroplasty with a New Convertible Short Stem: Preliminary 2- to 4-year Follow-up Results. J Shoulder Elb Arthroplast 2017. [DOI: 10.1177/2471549217746272] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023] Open
|
47
|
Werner BS, Chaoui J, Walch G. The influence of humeral neck shaft angle and glenoid lateralization on range of motion in reverse shoulder arthroplasty. J Shoulder Elbow Surg 2017; 26:1726-1731. [PMID: 28528016 DOI: 10.1016/j.jse.2017.03.032] [Citation(s) in RCA: 105] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Revised: 03/20/2017] [Accepted: 03/27/2017] [Indexed: 02/01/2023]
Abstract
BACKGROUND Recent developments in reverse shoulder arthroplasty (RSA) have focused on changes in several design-related parameters, including humeral component design, to allow for easier convertibility. Alterations in humeral inclination and offset on shoulder kinematics may have a relevant influence on postoperative outcome. This study used a virtual computer simulation to evaluate the influence of humeral neck shaft angle and glenoid lateralization on range of motion in onlay design RSA. METHODS Three-dimensional RSA computer templating was created from computed tomography (CT) scans in 20 patients undergoing primary total shoulder arthroplasty for concentric osteoarthritis (Walch A1). Two concurrent factors were tested for impingement-free range of motion: humeral inclination (135° vs. 145°) and glenoid lateralization (0 mm vs. 5 mm). RESULTS Decreasing the humeral neck shaft angle demonstrated a significant increase in impingement-free range of motion. Compared to the 145° configuration, extension was increased by 42.3° (-8.5° to 73.5°), adduction by 15° (10° to 23°), and external rotation with the arm at side by 15.1° (8.5° to 26.5°); however, abduction was decreased by 6.5° (-1° to 12.5°). Glenoid lateralization led to comparable results, but an additional increase in abduction of 7.6° (-1° to 16.5°) and forward flexion of 26.6° (6.5° to 62°) was observed. CONCLUSION Lower humeral neck shaft angle and glenoid lateralization are effective for improvement in range of motion after RSA. The use of the 135° model with 5 mm of glenoid lateralization provided the best results in impingement-free range of motion, except for abduction.
Collapse
Affiliation(s)
- Birgit S Werner
- Clinic for Shoulder and Elbow Surgery, Bad Neustadt/Saale, Germany; Centre Orthopédique Santy, Hôpital Jean Mermoz, Lyon, France.
| | | | - Gilles Walch
- Centre Orthopédique Santy, Hôpital Jean Mermoz, Lyon, France
| |
Collapse
|
48
|
Pre-operative factors influence the recovery of range of motion following reverse shoulder arthroplasty. INTERNATIONAL ORTHOPAEDICS 2017; 41:2135-2142. [DOI: 10.1007/s00264-017-3573-4] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Accepted: 06/30/2017] [Indexed: 11/25/2022]
|
49
|
Lädermann A, Denard PJ, Tirefort J, Collin P, Nowak A, Schwitzguebel AJP. Subscapularis- and deltoid-sparing vs traditional deltopectoral approach in reverse shoulder arthroplasty: a prospective case-control study. J Orthop Surg Res 2017; 12:112. [PMID: 28705164 PMCID: PMC5513373 DOI: 10.1186/s13018-017-0617-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 07/03/2017] [Indexed: 02/05/2023] Open
Abstract
Background With the growth of reverse shoulder arthroplasty (RSA), it is becoming increasingly necessary to establish the most cost-effective methods for the procedure. The surgical approach is one factor that may influence the cost and outcome of RSA. The purpose of this study was to compare the clinical results of a subscapularis- and deltoid-sparing (SSCS) approach to a traditional deltopectoral (TDP) approach for RSA. The hypothesis was that the SSCS approach would be associated with decreased length of stay (LOS), equal complication rate, and better short-term outcomes compared to the TDP approach. Methods A prospective evaluation was performed on patients undergoing RSA over a 2-year period. A deltopectoral incision was used followed by either an SSCS approach or a traditional tenotomy of the subscapularis (TDP). LOS, adverse events, physical therapy utilization, and patient satisfaction were collected in the 12 months following RSA. Results LOS was shorter with the SSCS approach compared to the TDP approach (from 8.2 ± 6.4 days to 15.2 ± 11.9 days; P = 0.04). At 3 months postoperative, the single assessment numeric evaluation score (80 ± 11% vs 70 ± 6%; P = 0.04) and active elevation (130 ± 22° vs 109 ± 24°; P = 0.01) were higher in the SSCS group. The SSCS approach resulted in a net cost savings of $5900 per patient. Postoperative physical therapy, pain levels, and patient satisfaction were comparable in both groups. No immediate intraoperative complications were noted. Conclusion Using a SSCS approach is an option for patients requiring RSA. Overall LOS is minimized compared to a TDP approach with subscapularis tenotomy. The SSCS approach may provide substantial healthcare cost savings, without increasing complication rate or decreasing patient satisfaction.
Collapse
Affiliation(s)
- Alexandre Lädermann
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Rue J.-D. Maillard 3, 1217, Meyrin, Switzerland. .,Faculty of Medicine, University of Geneva, Rue Michel-Servet 1, 1211, Geneva 4, Switzerland. .,Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, CH-1211, Geneva 14, Switzerland.
| | - Patrick Joel Denard
- Southern Oregon Orthopedics, Medford, Oregon, USA.,Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, Oregon, USA
| | - Jérome Tirefort
- Division of Orthopaedics and Trauma Surgery, Department of Surgery, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, CH-1211, Geneva 14, Switzerland
| | - Philippe Collin
- Saint-Grégoire Private Hospital Center, Boulevard Boutière 6, 35768, Saint-Grégoire cedex, France
| | - Alexandra Nowak
- Division of Orthopaedics and Trauma Surgery, La Tour Hospital, Rue J.-D. Maillard 3, 1217, Meyrin, Switzerland
| | | |
Collapse
|
50
|
Mathews S, Burkhard M, Serrano N, Link K, Häusler M, Frater N, Franke I, Bischofberger H, Buck FM, Gascho D, Thali M, Serowy S, Müller-Gerbl M, Harper G, Qureshi F, Böni T, Bloch HR, Ullrich O, Rühli FJ, Eppler E. Glenoid morphology in light of anatomical and reverse total shoulder arthroplasty: a dissection- and 3D-CT-based study in male and female body donors. BMC Musculoskelet Disord 2017; 18:9. [PMID: 28068966 PMCID: PMC5223371 DOI: 10.1186/s12891-016-1373-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2016] [Accepted: 12/19/2016] [Indexed: 11/19/2022] Open
Abstract
Background Placement of the glenoid baseplate is of paramount importance for the outcome of anatomical and reverse total shoulder arthroplasty. However, the database around glenoid size is poor, particularly regarding small scapulae, for example, in women and smaller individuals, and is derived from different methodological approaches. In this multimodality cadaver study, we systematically examined the glenoid using morphological and 3D-CT measurements. Methods Measurements of the glenoid and drill hole tunnel length for superior baseplate screw placement were recorded to define size of the glenoid and the distance to the scapular notch on cadaveric specimens. Glenoid angles were determined on both, 3D-CT-scans of the thoraxes using the Friedman method and on subsequently isolated scapulae from 18 male and female donors (average 84 years, range 60–98 years). Results Mean glenoid height was 36.6 mm ± 3.6, and width 27.8 mm ± 3.1 with a significant sex dimorphism (p ≤ 0.001): in males, glenoid height 39.5 mm ± 3.5, and width 30.3 mm ± 3.3, and in females, glenoid height 34.8 mm ± 2.2, and width 26.2 mm ± 1.6. The average distance from the superior screw entry to its exit in the scapular notch measured by calliper was 27.2 mm ± 6.0 with a sex difference: in males, 29.4 mm ± 5.7, and in females, 25.8 mm ± 5.9 mm with a minimum recorded distance of 15 mm. Measured by CT, the mean inclination angle for male and female donors combined was 13.0° ± 7.0, and the ante-/retroversion angle −1.0° ± 4.0°. Conclusion This study is one of the first to combine dissection, including drill holes, with anatomical measurements and radiological data. In some women and smaller individuals, smaller baseplates should be selected. The published safe zone of 20 mm is generally feasible for superior screw placement, however, in small patients this distance may be substantially shorter than expected and start as of 13 and 15 mm, respectively. No correlation between glenoid height or width with the length of our drilling canal towards the scapular notch was found. Preoperative CT-based treatment planning to determine version and inclination angles is recommended.
Collapse
Affiliation(s)
- Sandra Mathews
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland.
| | - Marco Burkhard
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Nabil Serrano
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland.,Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Karl Link
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland.,Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Martin Häusler
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland.,Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Nakita Frater
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland
| | - Ingeborg Franke
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Helena Bischofberger
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Florian M Buck
- Medical Radiology Institute, Schulthess Clinic, Zurich, Switzerland.,Medical Faculty, University of Zurich, Zurich, Switzerland
| | - Dominic Gascho
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Michael Thali
- Institute of Forensic Medicine, University of Zurich, Zurich, Switzerland
| | - Steffen Serowy
- Institute of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany
| | - Magdalena Müller-Gerbl
- Musculoskeletal Research Unit, Department of Biomedicine, University of Basel, Basel, Switzerland
| | - Gareth Harper
- Shoulder Unit, Queen Alexandra Hospital, Portsmouth, UK
| | - Ford Qureshi
- Shoulder Unit, Doncaster Royal Infirmary, Doncaster, UK
| | - Thomas Böni
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland.,Technical Orthopedics Unit, University Hospital Balgrist, Zurich, Switzerland
| | | | - Oliver Ullrich
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland
| | - Frank-Jakobus Rühli
- Institute of Evolutionary Medicine (IEM), University of Zurich, Winterthurerstrasse 190, CH-8057, Zurich, Switzerland
| | - Elisabeth Eppler
- Division of Gross Anatomy, Institute of Anatomy, University of Zurich, Zurich, Switzerland.,Institute of Neuroradiology, University Hospital Magdeburg, Magdeburg, Germany.,Musculoskeletal Research Unit, Department of Biomedicine, University of Basel, Basel, Switzerland
| |
Collapse
|