Zhou ZY, Zhu JX, Zhao DS, Ding BQ, Wang JL, Lin G. Evaluating the predictive efficacy of real-time 3D echocardiography in cardiac resynchronization therapy.
J Cardiothorac Surg 2024;
19:580. [PMID:
39354607 PMCID:
PMC11445956 DOI:
10.1186/s13019-024-03058-2]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2024] [Accepted: 09/15/2024] [Indexed: 10/03/2024] Open
Abstract
BACKGROUND
The aim of this study is to assess the predictive efficacy of real-time three-dimensional echocardiography (RT-3DE) and QRS wave duration in determining the response to cardiac resynchronization therapy (CRT) and assessing left ventricular systolic function pre- and post-CRT device implantation.
METHOD
A total of 51 patients with heart failure undergoing CRT at the Second Affiliated Hospital of Nantong University between January 1, 2013, and October 31, 2020, were enrolled in this study. Traditional two-dimensional echocardiography and RT-3DE were performed pre and post-CRT, with QRS wave width data from electrocardiograms and additional clinical information collected. Patients were categorized into CRT responder (n = 36) and CRT non-responder (n = 15) groups based on their response to CRT device implantation. Comparative analyses were conducted on the general characteristics of both groups, as well as the predictive efficacy of RT-3DE and QRS wave width for CRT responsiveness and left ventricular systolic function. Data on the standard deviation (Tmsv16-SD, Tmsv12-SD, Tmsv6-SD) and maximum difference (Tmsv16-Dif, Tmsv12-Dif, Tmsv6-Dif) of left ventricular end-systolic volume (LVESV) at segments 16, 12, and 6, as well as QRS wave width, were collected and analyzed.
RESULTS
The indicators Tmsv6-Dif, Tmsv12-Dif, Tmsv16-Dif, Tmsv6-SD, Tmsv12-SD, Tmsv16-SD, and QRS wave width exhibited significantly higher values in the CRT responder group when compared to the CRT non-responder group (P < 0.05). Among these, Tmsv16-SD demonstrated superior predictive performance for post-CRT response, with a sensitivity of 88.9%, specificity of 80.0%, and a diagnostic cut-off value of 6.19%. This predictive capability exceeded that of the conventional indicator, QRS wave width.
CONCLUSION
RT-3DE enables accurate prediction of post-CRT patient response and significantly facilitates quantitative assessment of CRT therapy efficacy.