1
|
Zhu Q, Guan J, Tian B, Wang P. Rational design of antibiotic-free antimicrobial contact lenses: Trade-offs between antimicrobial performance and biocompatibility. BIOMATERIALS ADVANCES 2024; 164:213990. [PMID: 39154560 DOI: 10.1016/j.bioadv.2024.213990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 07/20/2024] [Accepted: 08/05/2024] [Indexed: 08/20/2024]
Abstract
Microbial keratitis associated with contact lenses (CLs) wear remains a significant clinical concern. Antibiotic therapy is the current standard of care. However, the emergence of multidrug-resistant pathogens necessitates the investigation of alternative strategies. Antibiotic-free antimicrobial contact lenses (AFAMCLs) represent a promising approach in this regard. The effectiveness of CLs constructed with a variety of antibiotic-free antimicrobial strategies against microorganisms has been demonstrated. However, the impact of these antimicrobial strategies on CLs biocompatibility remains unclear. In the design and development of AFAMCLs, striking a balance between robust antimicrobial performance and optimal biocompatibility, including safety and wearing comfort, is a key issue. This review provides a comprehensive overview of recent advancements in AFAMCLs technology. The focus is on the antimicrobial efficacy and safety of various strategies employed in AFAMCLs construction. Furthermore, this review investigates the potential impact of these strategies on CLs parameters related to wearer comfort. This review aims to contribute to the continuous improvement of AFAMCLs and provide a reference for the trade-off between resistance to microorganisms and wearing comfort. In addition, it is hoped that this review can also provide a reference for the antimicrobial design of other medical devices.
Collapse
Affiliation(s)
- Qiang Zhu
- School of Pharmacy, Jiangsu Key Laboratory of Inflammation and Molecular Drug Targets, Nantong University, Nantong 226001, China.
| | - Jian Guan
- School of Pharmacy, Shenyang Key Laboratory of Intelligent Mucosal Drug Delivery Systems, Shenyang Pharmaceutical University, Shenyang 110016, China
| | - Bin Tian
- Department of Pharmaceutical Sciences, School of Biomedical and Pharmaceutical Sciences, Shaanxi University of Science and Technology, Xi'an 710021, China
| | - Puxiu Wang
- Department of Pharmacy, The First Hospital of China Medical University, Shenyang 110001, China.
| |
Collapse
|
2
|
Suliński T, Nowak N, Szymański J, Pniewski J. Analysis of Deposition and Diffusion of Cholesterol in Silicone Hydrogel Contact Lenses Using Confocal Microscopy. Vision (Basel) 2024; 8:55. [PMID: 39311323 PMCID: PMC11417713 DOI: 10.3390/vision8030055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2024] [Revised: 09/06/2024] [Accepted: 09/11/2024] [Indexed: 09/26/2024] Open
Abstract
In this study, we investigated lipid deposition and diffusion in silicone hydrogel (Si-Hy) contact lenses using confocal microscopy. Different Si-Hy lenses were analyzed to understand the interaction patterns of cholesterol with various lens materials. The results highlight significant differences in the deposition and diffusion of lipids through the lenses, revealing that some materials, such as comfilcon A, allow lipids to diffuse more freely compared to others, such as samfilcon A, which provides a greater barrier. The study also observed different morphology and movement of lipid agglomerates across the lenses and above it surfaces. These findings contribute to the understanding of lipid-lens interaction, which is important for the development of lenses with improved comfort and functionality. The research highlights the importance of considering lipid interactions in the design and selection of Si-Hy contact lenses to enhance wearer comfort and lens performance.
Collapse
Affiliation(s)
- Tomasz Suliński
- Alcon Polska, Marynarska 15, 02-674 Warsaw, Poland
- Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw, Poland;
| | - Natalia Nowak
- Nencki Institute of Experimental Biology PAS, Pasteura 3, 02-093 Warsaw, Poland; (N.N.)
| | - Jędrzej Szymański
- Nencki Institute of Experimental Biology PAS, Pasteura 3, 02-093 Warsaw, Poland; (N.N.)
| | - Jacek Pniewski
- Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw, Poland;
| |
Collapse
|
3
|
Puertas-Bartolomé M, Gutiérrez-Urrutia I, Teruel-Enrico LL, Duong CN, Desai K, Trujillo S, Wittmann C, Del Campo A. Self-Lubricating, Living Contact Lenses. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2313848. [PMID: 38583064 DOI: 10.1002/adma.202313848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Revised: 03/04/2024] [Indexed: 04/08/2024]
Abstract
The increasing prevalence of dry eye syndrome in aging and digital societies compromises long-term contact lens (CL) wear and forces users to regular eye drop instillation to alleviate discomfort. Here a novel approach with the potential to improve and extend the lubrication properties of CLs is presented. This is achieved by embedding lubricant-secreting biofactories within the CL material. The self-replenishable reservoirs autonomously produce and release hyaluronic acid (HA), a natural lubrication and wetting agent, long term. The hydrogel matrix regulates the growth of the biofactories and the HA production, and allows the diffusion of nutrients and HA for at least 3 weeks. The continuous release of HA sustainably reduces the friction coefficient of the CL surface. A self-lubricating CL prototype is presented, where the functional biofactories are contained in a functional ring at the lens periphery, outside of the vision area. The device is cytocompatible and fulfils physicochemical requirements of commercial CLs. The fabrication process is compatible with current manufacturing processes of CLs for vision correction. It is envisioned that the durable-by-design approach in living CL could enable long-term wear comfort for CL users and minimize the need for lubricating eye drops.
Collapse
Affiliation(s)
- María Puertas-Bartolomé
- INM-Leibniz Institute for New Materials, Campus D2 2, 66123, Saarbrücken, Germany
- Chemistry Department, Saarland University, 66123, Saarbrücken, Germany
| | | | | | - Cao Nguyen Duong
- INM-Leibniz Institute for New Materials, Campus D2 2, 66123, Saarbrücken, Germany
| | - Krupansh Desai
- INM-Leibniz Institute for New Materials, Campus D2 2, 66123, Saarbrücken, Germany
| | - Sara Trujillo
- INM-Leibniz Institute for New Materials, Campus D2 2, 66123, Saarbrücken, Germany
| | - Christoph Wittmann
- Institute for Systems Biotechnology, Saarland University, Campus A1 5, 66123, Saarbrücken, Germany
| | - Aránzazu Del Campo
- INM-Leibniz Institute for New Materials, Campus D2 2, 66123, Saarbrücken, Germany
- Chemistry Department, Saarland University, 66123, Saarbrücken, Germany
| |
Collapse
|
4
|
Yamasaki K, Dantam J, Sasanuma K, Hisamura R, Mizuno Y, Hui A, Jones L. Impact of in vitro lens deposition and removal on bacterial adhesion to orthokeratology contact lenses. Cont Lens Anterior Eye 2024; 47:102104. [PMID: 38161140 DOI: 10.1016/j.clae.2023.102104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 11/22/2023] [Accepted: 12/11/2023] [Indexed: 01/03/2024]
Abstract
PURPOSE The purpose of this study was to explore the impact of several contact lens (CL) care solutions on the removal of proteins and lipids, and how deposit removal impacts bacterial adhesion and solution disinfection. METHODS Lysozyme and lipid deposition on three ortho-k (rigid) and two soft CL materials were evaluated using an ELISA kit and gas chromatography respectively. Bacterial adhesion to a fluorosilicone acrylate material using Pseudomonas aeruginosa with various compositions of artificial tear solutions (ATS), including with denatured proteins, was also investigated. The impact of deposition of the different formulations of ATS on biofilm formation was explored using cover slips. Finally, the lysozyme and lipid cleaning efficacy and disinfection efficacy against P. aeruginosa and Staphylococcus aureus of four different contact lens care solutions were studied using qualitative analysis. RESULTS While maximum lysozyme deposition was observed with the fluorosilicone acrylate material (327.25 ± 54.25 µg/lens), the highest amount of lipid deposition was recorded with a fluoro-siloxanyl styrene material (134.71 ± 19.87 µg/lens). Adhesion of P. aeruginosa to fluorosilicone acrylate lenses and biofilm formation on cover slips were significantly greater with the addition of denatured proteins and lipids. Of the four contact lens care solutions investigated, the solution based on povidone-iodine removed both denatured lysozyme and lipid deposits and could effectively disinfect against P. aeruginosa and S. aureus when contaminated with denatured proteins and lipids. In contrast, the peroxide-based solution was able to inhibit P. aeruginosa growth only, while the two multipurpose solutions were unable to disinfect lenses contaminated with denatured proteins and lipids. CONCLUSION Bacterial adhesion and biofilm formation is influenced by components within artificial tear solutions depositing on lenses, including denatured proteins and lipids, which also affects disinfection. The ability of different solutions to remove these deposits should be considered when selecting systems to clean and disinfect ortho-k lenses.
Collapse
Affiliation(s)
| | - Jaya Dantam
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada
| | | | | | - Yohei Mizuno
- Kobe Research Center, OPHTECS Corporation, Kobe, Japan
| | - Alex Hui
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Australia.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Ontario, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong Special Administrative Region, Hong Kong
| |
Collapse
|
5
|
Scheuer C, Barniak VL, Phatak NR, Rah MJ, Reindel W. Effect of Contact Lens Solutions in Stabilizing the Activity of Tear Lysozyme [Response to Letter]. CLINICAL OPTOMETRY 2024; 16:81-82. [PMID: 38444786 PMCID: PMC10913791 DOI: 10.2147/opto.s463864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 02/26/2024] [Indexed: 03/07/2024]
Affiliation(s)
| | | | | | - Marjorie J Rah
- Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA
| | | |
Collapse
|
6
|
Sun Y, Wang J, Li D, Cheng F. The Recent Progress of the Cellulose-Based Antibacterial Hydrogel. Gels 2024; 10:109. [PMID: 38391439 PMCID: PMC10887981 DOI: 10.3390/gels10020109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 01/26/2024] [Accepted: 01/26/2024] [Indexed: 02/24/2024] Open
Abstract
Cellulose-based antibacterial hydrogel has good biocompatibility, antibacterial performance, biodegradability, and other characteristics. It can be very compatible with human tissues and degradation, while its good water absorption and moisturizing properties can effectively absorb wound exudates, keep the wound moist, and promote wound healing. In this paper, the structural properties, and physical and chemical cross-linking preparation methods of cellulose-based antibacterial hydrogels were discussed in detail, and the application of cellulose-based hydrogels in the antibacterial field was deeply studied. In general, cellulose-based antibacterial hydrogels, as a new type of biomaterial, have shown good potential in antimicrobial properties and have been widely used. However, there are still some challenges, such as optimizing the preparation process and performance parameters, improving the antibacterial and physical properties, broadening the application range, and evaluating safety. However, with the deepening of research and technological progress, it is believed that cellulose-based antibacterial hydrogels will be applied and developed in more fields in the future.
Collapse
Affiliation(s)
- Ying Sun
- College of Light Industry and Textile, Qiqihar University, Qiqihar 161006, China
- Cold Area Hemp and Products Engineering Research Center of Ministry of Education, Qiqihar 161006, China
| | - Jiayi Wang
- College of Light Industry and Textile, Qiqihar University, Qiqihar 161006, China
| | - Duanxin Li
- College of Light Industry and Textile, Qiqihar University, Qiqihar 161006, China
- Cold Area Hemp and Products Engineering Research Center of Ministry of Education, Qiqihar 161006, China
| | - Feng Cheng
- School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin 150001, China
| |
Collapse
|
7
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
8
|
Zhao M, Huang M, Li Z. Exploring the therapeutic potential of recombinant human lysozyme: a review on wound management system with antibacterial. Front Bioeng Biotechnol 2023; 11:1292149. [PMID: 38026866 PMCID: PMC10646323 DOI: 10.3389/fbioe.2023.1292149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 12/01/2023] Open
Abstract
Lysozyme, a natural antibacterial enzyme protein, possesses the ability to dissolve the cell walls of Gram-positive bacteria, demonstrating broad-spectrum antibacterial activity. Despite its significant potential in treating wound infections and promoting wound healing, its widespread clinical application has yet to be realized. Current research is primarily focused on carrier-based delivery systems for lysozyme. In this review, we discuss four delivery systems that can be employed for lysozyme in wound healing treatment, specifically hydrogels, nanofilms, electrospun fibrous membranes, and modified-lysozyme composite systems. These systems not only enhance the stability of lysozyme but also enable its controlled and sustained release at wound sites, potentially overcoming some of the challenges associated with its direct application. Lastly, we delve into the perspectives and challenges related to the use of these delivery systems, hoping to spur further research and innovation in this promising field.
Collapse
Affiliation(s)
- Meiping Zhao
- Nursing Department, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Meili Huang
- Nursing Department, Sir Run Run Shaw Hospital Affiliated to Zhejiang University School of Medicine Alar Hospital, Alar, China
| | - Zhen Li
- Emergency Department, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
| |
Collapse
|
9
|
Zhu Q, Zhang Q, Fu DY, Su G. Polysaccharides in contact lenses: From additives to bulk materials. Carbohydr Polym 2023; 316:121003. [PMID: 37321708 DOI: 10.1016/j.carbpol.2023.121003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/26/2023] [Accepted: 05/07/2023] [Indexed: 06/17/2023]
Abstract
As the number of applications has increased, so has the demand for contact lenses comfort. Adding polysaccharides to lenses is a popular way to enhance comfort for wearers. However, this may also compromise some lens properties. It is still unclear how to balance the variation of individual lens parameters in the design of contact lenses containing polysaccharides. This review provides a comprehensive overview of how polysaccharide addition impacts lens wear parameters, such as water content, oxygen permeability, surface wettability, protein deposition, and light transmittance. It also examines how various factors, such as polysaccharide type, molecular weight, amount, and mode of incorporation into lenses modulate these effects. Polysaccharide addition can improve some wear parameters while reducing others depending on the specific conditions. The optimal method, type, and amount of added polysaccharides depend on the trade-off between various lens parameters and wear requirements. Simultaneously, polysaccharide-based contact lenses may be a promising option for biodegradable contact lenses as concerns regarding environmental risks associated with contact lens degradation continue to increase. It is hoped that this review will shed light on the rational use of polysaccharides in contact lenses to make personalized lenses more accessible.
Collapse
Affiliation(s)
- Qiang Zhu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Qiao Zhang
- Department of Clinical Pharmacy, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China
| | - Ding-Yi Fu
- School of Pharmacy, Nantong University, Nantong 226001, China
| | - Gaoxing Su
- School of Pharmacy, Nantong University, Nantong 226001, China.
| |
Collapse
|
10
|
Su CY, Yeh LK, Huang PH, Lin WP, Huang HF, Lai CC, Fang HW. Long-term effects of tear film component deposition on the surface and optical properties of two different orthokeratology lenses. Cont Lens Anterior Eye 2023; 46:101852. [PMID: 37150645 DOI: 10.1016/j.clae.2023.101852] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 03/08/2023] [Accepted: 04/28/2023] [Indexed: 05/09/2023]
Abstract
PURPOSE To understand the effects of long-term deposition of tear film components on the surface and optical properties of orthokeratology (ortho-k) lenses, two different lenses, Brighten 22 and Optimum Extra, were tested here. METHODS Ortho-k lenses were immersed in artificial tears and cleaned with a commercial care solution repeatedly for up to 90 days. Both the daily and accumulated lysozyme deposition amounts using an Enzyme-Linked ImmunoSorbent Assay were then analyzed. The base curve, central thickness, power, and transmission of visible light, ultraviolet A, and ultraviolet B were analyzed before and after repeated tear film component deposition procedures. The surface roughness using atomic force microscopy was observed and an energy dispersive spectrometer was used to analyze the composition of the deposits. RESULTS The highest levels of lysozyme were adsorbed on both lens materials during the first four days of the procedure and became saturated by day 6. For both lens materials, contamination on the lenses was easily observed by day 30, and the degree of surface roughness was higher. The transmission levels of different light spectrums were reduced showing that the optical characteristics of both lenses were also affected. CONCLUSIONS The results provide in vitro evidence that lysozyme could not be completely removed from orthokeratology lenses. Both surface and optical properties were affected by the deposition of tear film components. However, only one commercial multipurpose care solution was used to clean the lens in this study when the main ingredient was a surfactant, and the results might be different when other care regimens with other key ingredients are used. In addition, whether tear film component deposition might result in increased risks of infection or corneal abrasion will require further investigation.
Collapse
Affiliation(s)
- Chen-Ying Su
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Lung-Kun Yeh
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, No. 5, Fuxing St., Taoyuan 333, Taiwan; College of Medicine, Chang Gung University, No. 259, Wenhua 1st Rd., Taoyuan 333, Taiwan
| | - Pin-Hsuan Huang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan
| | - Wen-Pin Lin
- Research and Development Center, Brighten Optix Co., 6F-1, No. 150, Sec.4, Chengde Rd., Shilin Dist., Taipei 111, Taiwan; Department of Optometry, University of Kang Ning, No. 137, Alley 75, Sec. 3, Kang Ning Road, Neihu District, Taipei 11485, Taiwan
| | - Hsueh-Fang Huang
- Research and Development Center, Brighten Optix Co., 6F-1, No. 150, Sec.4, Chengde Rd., Shilin Dist., Taipei 111, Taiwan
| | - Chi-Chun Lai
- Department of Ophthalmology, Chang Gung Memorial Hospital, Linkou, No. 5, Fuxing St., Taoyuan 333, Taiwan; College of Medicine, Chang Gung University, No. 259, Wenhua 1st Rd., Taoyuan 333, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology. 1, Sec. 3, Zhongxiao E. Rd., Taipei 10608, Taiwan; Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes, No. 35, Keyan Road, Zhunan Town, Miaoli County 35053, Taiwan.
| |
Collapse
|
11
|
Nath H, Sarmah RJ, Kundu S. Langmuir monolayer of lysozyme at variable subphase pH conditions: a comprehensive study on structure, morphology and hysteresis behaviour. RSC Adv 2023; 13:22789-22799. [PMID: 37520086 PMCID: PMC10373444 DOI: 10.1039/d3ra03710j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Accepted: 07/15/2023] [Indexed: 08/01/2023] Open
Abstract
Formation of a pure Langmuir monolayer of lysozyme at the air-water interface and its investigation by means of a surface pressure (π)-mean molecular area (A) isotherm has been accomplished under different subphase pH conditions. A normalized area-time curve confirms the stable nature of the lysozyme monolayer whose compressibility variation with an increased surface pressure at specific subphase pH has also been studied from π-A isotherms. The monolayers exhibit irreversible hysteresis behaviour irrespective of subphase pH conditions, as evidenced from successive compression-expansion π-A isotherm cycles. Comparison of surface thermodynamics under hysteresis with subphase pH variation confirms that the monolayer at subphase pH ≈ 4.0 involves a greater amount of energy to attain and retain the ordered and compact monolayer than the other two pH conditions (pH ≈ 7.0 and 9.5). In situ visualization of lysozyme monolayers by Brewster angle microscopy suggests the homogeneous and stripe-like pattern formation at lower and higher surface pressure respectively. Further investigations of lysozyme films at solid surfaces have been carried out with atomic force microscopy and X-ray reflectivity (XRR) analysis. Structural reversibility of lysozyme molecules under compression-expansion-compression of the monolayer is revealed from the comparison of height profiles of AFM images and electron density profiles as extracted from XRR analysis of the films deposited during both first and second compressions of the monolayer. The mechanism of the structural rearrangement of lysozyme molecules with surface pressure variation at different subphase pH is explored, correlating macroscopic and microscopic information.
Collapse
Affiliation(s)
- Himadri Nath
- Soft Nano Laboratory (SNL), Physical Sciences Division, Institute of Advanced Study in Science and Technology (IASST) Vigyan Path, Paschim Boragaon, Garchuk Guwahati Assam 781035 India
- Academy of Scientific and Innovative Research (AcSIR) Ghaziabad 201002 India
| | - Raktim J Sarmah
- Soft Nano Laboratory (SNL), Physical Sciences Division, Institute of Advanced Study in Science and Technology (IASST) Vigyan Path, Paschim Boragaon, Garchuk Guwahati Assam 781035 India
| | - Sarathi Kundu
- Soft Nano Laboratory (SNL), Physical Sciences Division, Institute of Advanced Study in Science and Technology (IASST) Vigyan Path, Paschim Boragaon, Garchuk Guwahati Assam 781035 India
- Academy of Scientific and Innovative Research (AcSIR) Ghaziabad 201002 India
| |
Collapse
|
12
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
13
|
Ahn J, Choi M. The Ionization of Polymeric Materials Accelerates Protein Deposition on Hydrogel Contact Lens Material. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2119. [PMID: 36903237 PMCID: PMC10004484 DOI: 10.3390/ma16052119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/24/2023] [Accepted: 03/03/2023] [Indexed: 06/18/2023]
Abstract
Contact lens materials include polymers that are ionized in the ocular pH condition and are susceptible to protein deposition due to their surface characteristics. Herein, we investigated the effect of the electrostatic state of the contact lens material and protein on protein deposition level using hen egg white lysozyme (HEWL) and bovine serum albumin (BSA) as model proteins and etafilcon A and hilafilcon B as model contact lens materials. Only HEWL deposition on etafilcon A showed a statistically significant pH-dependency (p < 0.05); protein deposition increased with pH. HEWL showed a positive zeta potential at acidic pH, while BSA showed a negative zeta potential at basic pH. Only etafilcon A showed a statistically significant pH-dependent point of zero charge (PZC) (p < 0.05), implying that its surface charge became more negative under basic conditions. This pH-dependency of etafilcon A is attributed to the pH-responsive degree of ionization of its constituent methacrylic acid (MAA). The presence of MAA and its degree of ionization could accelerate protein deposition; more HEWL deposited as pH increased despite the weak positive surface charge of HEWL. The highly negatively charged etafilcon A surface attracted HEWL, even overwhelming weak positive charge of HEWL, increasing the deposition with pH.
Collapse
Affiliation(s)
- Jihye Ahn
- Department of Optometry, College of Energy and Biotechnology, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
| | - Moonsung Choi
- Department of Optometry, College of Energy and Biotechnology, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
- Convergence Institute of Biomedical Engineering and Biomaterials, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea
| |
Collapse
|
14
|
Scheuer CA, Barniak VL, Phatak NR, Rah MJ, Reindel W. Effect of Contact Lens Solutions in Stabilizing the Activity of Tear Lysozyme. CLINICAL OPTOMETRY 2023; 15:119-127. [PMID: 37205004 PMCID: PMC10187650 DOI: 10.2147/opto.s404261] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Accepted: 04/17/2023] [Indexed: 05/21/2023]
Abstract
Purpose Interactions between tear proteins and the interfaces of contact lenses can be complex and can influence contact lens wear success. Tear proteins, including lysozyme, function to maintain the balance of ocular surface homeostasis, as evidenced by the effects of its conformation relative to stabilizing the tear film and its potential impact on corneal epithelial cells. Contact lens manufacturers include components in lens care and blister package solutions to help stabilize the tear film and preserve homeostasis. This in vitro study was performed to evaluate the ability of daily disposable contact lens package solutions to stabilize lysozyme and preserve its native conformation under denaturing conditions. Methods Lysozyme was added to contact lens solutions sampled from kalifilcon A, etafilcon A, senofilcon A, narafilcon A, nelfilcon A, verofilcon A, delefilcon A, somofilcon A, and stenfilcon A blister packages, then mixed with the protein denaturant sodium lauryl sulfate. Lysozyme activity was evaluated by adding test solutions to a suspension of Micrococcus luteus. Native lysozyme lyses the Micrococcus luteus cell wall, which decreases suspension turbidity. Stabilization of lysozyme activity was determined by comparing suspension turbidity before and after exposure to test solutions. Results Lysozyme stabilization was 90.7% for kalifilcon A solution, a statistically significant improvement (p < 0.05) compared to phosphate buffered saline (PBS, negative control). No significant improvement was observed with any other contact lens solution (all lysozyme stabilization < 5.00%). Conclusion The representative tear protein lysozyme was significantly more stable in the novel kalifilcon A contact lens solution containing multiple moisturizers and osmoprotectants than in PBS or other daily disposable contact lens solutions. The lysozyme activity assay provides mechanistic evidence that the kalifilcon A contact lens solution can stabilize proteins under conditions that typically denature proteins, which may contribute to maintaining ocular surface homeostasis.
Collapse
Affiliation(s)
| | | | - Nitasha R Phatak
- Vision Care, Bausch & Lomb Inc., Rochester, NY, USA
- Correspondence: Nitasha R Phatak, Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA, Tel +1 585 413-6397, Email
| | | | | |
Collapse
|
15
|
Contact Lens Wear Induces Alterations of Lactoferrin Functionality in Human Tears. Pharmaceutics 2022; 14:pharmaceutics14102188. [PMID: 36297623 PMCID: PMC9612143 DOI: 10.3390/pharmaceutics14102188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 10/10/2022] [Accepted: 10/12/2022] [Indexed: 11/06/2022] Open
Abstract
The tear film is a complex matrix composed of several molecular classes, from small metal ions to macromolecules. Contact lens (CL) wear can affect the protein homeostasis of the tear film, by accumulating deposits on the CL surface and/or altering their structural and functional properties. This work investigates the effect of CL wear on lactoferrin (Lf), one of the most abundant tear proteins, known as an unspecific biomarker of inflammation. Tears from eight volunteers were collected and analyzed after alternated periods of CL wear and without CL. The experimental approach is to probe Lf into unprocessed human tears by the peculiar fluorescence emission originating from complex formation of Lf with terbium (Tb3+) at the iron-binding sites. The experimental data indicate that CL wear does not significantly affect the total amount of Lf. On the other hand, Lf affinity for Tb3+ is reduced upon CL wear, suggesting relevant changes in Lf structure and possible alterations of protein functionality. Future studies based on this approach will help define CL features (material, lens-care solution, wearing time, etc.) with minimal effects on tear protein activity, in order to obtain more biocompatible and comfortable devices.
Collapse
|
16
|
Cathcarth M, Picco AS, Mondo GB, Cardoso MB, Longo GS. Competitive protein adsorption on charge regulating silica-like surfaces: the role of protonation equilibrium. JOURNAL OF PHYSICS. CONDENSED MATTER : AN INSTITUTE OF PHYSICS JOURNAL 2022; 34:364001. [PMID: 35366656 DOI: 10.1088/1361-648x/ac6388] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 04/01/2022] [Indexed: 06/14/2023]
Abstract
We develop a molecular thermodynamic theory to study the interaction of some proteins with a charge regulating silica-like surface under a wide range of conditions, including pH, salt concentration and protein concentration. Proteins are modeled using their three dimensional structure from crystallographic data and the average experimental pKa of amino acid residues. As model systems, we study single-protein and binary solutions of cytochrome c, green fluorescent protein, lysozyme and myoglobin. Our results show that protonation equilibrium plays a critical role in the interactions of proteins with these type of surfaces. The terminal hydroxyl groups on the surface display considerable extent of charge regulation; protein residues with titratable side chains increase protonation according to changes in the local environment and the drop in pH near the surface. This behavior defines protein-surface interactions and leads to the emergence of several phenomena: (i) a complex non-ideal surface charge behavior; (ii) a non-monotonic adsorption of proteins as a function of pH; and (iii) the presence of two spatial regions, a protein-rich and a protein-depleted layer, that occur simultaneously at different distances from the surface when pH is slightly above the isoelectric point of the protein. In binary mixtures, protein adsorption and surface-protein interactions cannot be predicted from single-protein solution considerations.
Collapse
Affiliation(s)
- Marilina Cathcarth
- Instituto de Investigaciones Fisicoquímicas, Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| | - Agustin S Picco
- Instituto de Investigaciones Fisicoquímicas, Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| | - Gabriela B Mondo
- Brazilian Synchrotron (LNLS) and Brazilian Nanotechnology Laboratory (LNNano), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, Brazil
- Institute of Chemistry (IQ), University of Campinas (UNICAMP), Campinas, Brazil
| | - Mateus B Cardoso
- Brazilian Synchrotron (LNLS) and Brazilian Nanotechnology Laboratory (LNNano), Brazilian Center for Research in Energy and Materials (CNPEM), Campinas, Brazil
- Institute of Chemistry (IQ), University of Campinas (UNICAMP), Campinas, Brazil
| | - Gabriel S Longo
- Instituto de Investigaciones Fisicoquímicas, Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| |
Collapse
|
17
|
Xu Y, Li H. In vitro and in vivo evaluation of brimonidine loaded silica nanoparticles-laden silicone contact lenses to manage glaucoma. J Biomater Appl 2022; 37:333-343. [PMID: 35482359 DOI: 10.1177/08853282221090880] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Glaucoma is treated by frequent instillation of 0.2% w/v brimonidine tartrate eye drop solution, which showed poor ocular bioavailability of 1-3%. Medicated contact lenses can be used to improve the ocular drug bioavailability. However, drug loading in the contact lens matrix showed high burst release and changes the optophysical properties of the contact lens material. In this paper, a novel brimonidine loaded silica nanoparticles-laden silicone contact lenses (Bri-Si) were designed to achieve controlled drug delivery without altering the optophysical properties of the contact lens. Silica nanoparticles were prepared by polymerizing octadecyltrimethoxysilane (OTMS) molecules at the oil/water interface of microemulsion. Traditional soaking method (Bri-SM), direct brimonidine-loading method (Bri-DL) and microemulsion-laden contact lens (Bri-ME) were developed for comparison. The Bri-Si lens showed improved swelling, transmittance, oxygen permeability and lysozyme adherence compared to Bri-SM, Bri-DL and Bri-ME lenses. The Bri-DL lens showed high brimonidine leaching during extraction and sterilization steps, with low cumulative drug release. While, Bri-Si lens show controlled brimonidine release for 144 h. In a rabbit tear fluid model, the Bri-Si lens showed high brimonidine concentration for 96 h compared to Bri-ME lens and eye drop therapy. Based on histopathological studies of cornea, the Bri-Si lens was found to be safe for human applications. The data demonstrated the novel application of silica nanoparticles to control brimonidine release from the contact lens without altering the optophysical properties of the contact lens.
Collapse
Affiliation(s)
- Yunli Xu
- Department of Ophtalmology, 74723Zhenjiang Hospital Affiliated to Nanjing University of Chinese Medicine (Zhenjiang Hospital of Traditional Chinese Medicine), Zhenjiang, Jiangsu Province, 212008, China
| | - Hongyi Li
- Department of Ophtalmology, 12432Heilongjiang University Hospital, Heilongjiang University, Harbin, Heilongjiang Province, 150080, China
| |
Collapse
|
18
|
Carpa R, Remizovschi A, Culda CA, Butiuc-Keul AL. Inherent and Composite Hydrogels as Promising Materials to Limit Antimicrobial Resistance. Gels 2022; 8:70. [PMID: 35200452 PMCID: PMC8870943 DOI: 10.3390/gels8020070] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 12/22/2021] [Accepted: 01/11/2022] [Indexed: 01/25/2023] Open
Abstract
Antibiotic resistance has increased significantly in the recent years, and has become a global problem for human health and the environment. As a result, several technologies for the controlling of health-care associated infections have been developed over the years. Thus, the most recent findings in hydrogel fabrication, particularly antimicrobial hydrogels, could offer valuable solutions for these biomedical challenges. In this review, we discuss the most promising strategies in the development of antimicrobial hydrogels and the application of hydrogels in the treatment of microbial infections. The latest advances in the development of inherently and composite antimicrobial hydrogels will be discussed, as well as hydrogels as carriers of antimicrobials, with a focus on antibiotics, metal nanoparticles, antimicrobial peptides, and biological extracts. The emergence of CRISR-Cas9 technology for removing the antimicrobial resistance has led the necessity of new and performant carriers for delivery of the CRISPR-Cas9 system. Different delivery systems, such as composite hydrogels and many types of nanoparticles, attracted a great deal of attention and will be also discussed in this review.
Collapse
Affiliation(s)
- Rahela Carpa
- Molecular Biology and Biotechnology Department, Faculty of Biology and Geology, Babeş-Bolyai University, 1 M. Kogalniceanu Street, 400084 Cluj-Napoca, Romania; (R.C.); (A.L.B.-K.)
- Center of Systems Biology, Biodiversity and Bioresources, Babeş-Bolyai University, 5-7 Clinicilor Street, 400006 Cluj-Napoca, Romania
| | - Alexei Remizovschi
- Molecular Biology and Biotechnology Department, Faculty of Biology and Geology, Babeş-Bolyai University, 1 M. Kogalniceanu Street, 400084 Cluj-Napoca, Romania; (R.C.); (A.L.B.-K.)
- Center of Systems Biology, Biodiversity and Bioresources, Babeş-Bolyai University, 5-7 Clinicilor Street, 400006 Cluj-Napoca, Romania
| | - Carla Andreea Culda
- Parasitology and Parasitic Diseases Department, University of Agricultural Sciences and Veterinary Medicine, 3-5 Calea Manastur Street, 400372 Cluj-Napoca, Romania;
| | - Anca Livia Butiuc-Keul
- Molecular Biology and Biotechnology Department, Faculty of Biology and Geology, Babeş-Bolyai University, 1 M. Kogalniceanu Street, 400084 Cluj-Napoca, Romania; (R.C.); (A.L.B.-K.)
- Center of Systems Biology, Biodiversity and Bioresources, Babeş-Bolyai University, 5-7 Clinicilor Street, 400006 Cluj-Napoca, Romania
| |
Collapse
|
19
|
Chang WH, Liu PY, Lin DE, Jiang YT, Lu CJ, Hsu YHH. Dynamic Protein Adsorption-Desorption Analysis of Contact Lenses in a Three-Dimensional-Printed Eye Model. Macromol Res 2022. [DOI: 10.1007/s13233-022-0003-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
20
|
Masoudi S, Willcox M. Development of an enzymatic method for the evaluation of protein deposition on contact lenses. BIOFOULING 2022; 38:84-99. [PMID: 35016572 DOI: 10.1080/08927014.2021.2019225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 12/09/2021] [Accepted: 12/10/2021] [Indexed: 06/14/2023]
Abstract
The aim of this study was to evaluate a new digestion method to quantify protein deposition on contact lenses. Four silicone hydrogel and one hydrogel contact lens material were incubated in lactoferrin, lysozyme, immunoglobulin A, and bovine serum albumin solutions at approximate physiological concentrations and temperature. Immobilized trypsin was used to digest the protein deposits from the contact lens surfaces. The total protein absorbed to lenses was extracted and digested using sequencing grade trypsin. The tryptic peptides were quantified using selected reaction monitoring mass spectrometry. The concentration of surface protein deposits was either lower than or the same as the total protein for all lens types and proteins. Immobilised trypsin can digest protein deposits from the surface of contact lenses. This ability to analyse the amount of protein at a contact lens surface may help in elucidating the effect of surface deposition on clinical outcomes during lens wear.
Collapse
Affiliation(s)
- Simin Masoudi
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
21
|
Kamiya T, Komatsu S, Kikuchi A. Protein Removal from Hydrogels through Repetitive Surface Degradation. ACS APPLIED BIO MATERIALS 2021; 4:8498-8502. [PMID: 35005931 PMCID: PMC8693177 DOI: 10.1021/acsabm.1c00993] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
![]()
Suppression of protein
adsorption is a necessary property for materials
used in the living body. In this study, thermoresponsive and degradable
hydrogels were prepared by the radical polymerization of 2-methylene-1,3-dioxepane,
2-hydroxyethyl acrylate (HEA), and poly(ethylene glycol) monomethacrylate
(PEGMA). The prepared hydrogels re-exposed PEG-grafted chains to the
interface through surface degradation, which was confirmed by the
maintenance of the chemical composition of the hydrogel surfaces after
hydrolysis. Notably, adsorbed proteins can be removed from the hydrogel
surfaces through hydrogel surface degradation at least thrice.
Collapse
Affiliation(s)
- Tatsuki Kamiya
- Department of Materials Science and Technology, Tokyo University of Science, 6-3-1 Niijuku,
Katsushika-ku, Tokyo 125-8585, Japan
| | - Syuuhei Komatsu
- Department of Materials Science and Technology, Tokyo University of Science, 6-3-1 Niijuku,
Katsushika-ku, Tokyo 125-8585, Japan
| | - Akihiko Kikuchi
- Department of Materials Science and Technology, Tokyo University of Science, 6-3-1 Niijuku,
Katsushika-ku, Tokyo 125-8585, Japan
| |
Collapse
|
22
|
The Effect of Different Cleaning Methods on Protein Deposition and Optical Characteristics of Orthokeratology Lenses. Polymers (Basel) 2021; 13:polym13244318. [PMID: 34960869 PMCID: PMC8707220 DOI: 10.3390/polym13244318] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/06/2021] [Accepted: 12/07/2021] [Indexed: 11/29/2022] Open
Abstract
Orthokeratology lenses are commonly used for myopia control, especially in children. Tear lipids and proteins are immediately adsorbed when the lens is put on the cornea, and protein deposition may cause discomfort or infection. Therefore, we established an in vitro protein deposition analysis by mimicking the current cleaning methods for orthokeratology lens wearers for both short-term and long-term period. The results showed that the amounts of tear proteins accumulated daily and achieved a balance after 14 days when the lens was rubbed to clean or not. Protein deposition also affected the optical characteristics of the lens regardless of cleaning methods. Our results provided an in vitro analysis for protein deposition on the lens, and they may provide a potential effective method for developing care solutions or methods that can more effectively remove tear components from orthokeratology lenses.
Collapse
|
23
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
24
|
Chernysheva MG, Shnitko AV, Skrabkova HS, Badun GA. Peculiarities of alkylamidopropyldimethylbenzylammonium (Miramistin) in the relationship to lysozyme in comparison with quaternary ammonium surfactants: Coadsorption at the interfaces, enzymatic activity and molecular docking. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
25
|
Kita M, Kanai K, Ono HK, Otaka Y, Okada D, Nagai N, Kudo R, Yamashita Y, Hino S, Matsunaga T, Tajima K. Retention, Bacterial Adhesion, and Biofilm Formation between Anionic and Zwitterionic Bandage Contact Lenses in Healthy Dogs: A Pilot Study. Vet Sci 2021; 8:vetsci8100238. [PMID: 34679069 PMCID: PMC8539595 DOI: 10.3390/vetsci8100238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2021] [Revised: 10/11/2021] [Accepted: 10/16/2021] [Indexed: 12/03/2022] Open
Abstract
This study aimed to compare the in vitro and in vivo retention, bacterial adhesion, and biofilm formation between anionic and zwitterionic bandage contact lenses (BCLs) in healthy canines. BCL retention and tolerance were evaluated in 10 healthy canines via a single-masked, crossover study for 7 days. To compare in vitro bacterial adhesion and biofilm formation, four Staphylococcus strains were incubated with the BCLs at 37 °C for 2 or 24 h, and the bacterial colony forming units (CFUs) adhering to the BCLs were counted. Next, to compare in vivo bacterial adhesion, the CFUs of bacteria adhering to the BCLs worn by canines for 24 h were counted. Anionic lenses significantly retained and reduced in vitro bacterial adhesion than in the zwitterionic lenses. However, the amount of in vitro biofilm formation was more likely to be higher on anionic lenses than on zwitterionic lenses. In vivo bacterial adhesion was not significantly different between the two types of BCLs. Nevertheless, both BCLs were well-tolerated by the canines; thus, their short-term use in dogs can be recommended as safe.
Collapse
Affiliation(s)
- Mizuki Kita
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| | - Kazutaka Kanai
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
- Correspondence: ; Tel.: +81-176-23-4371
| | - Hisaya K. Ono
- Department of Zoonoses, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan;
| | - Yuya Otaka
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| | - Daiki Okada
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| | - Noriaki Nagai
- Faculty of Pharmacy, Kindai University, 3-4-1 Kowakae, Higashi-Osaka, Osaka 577-8502, Japan;
| | - Rina Kudo
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| | - Yohei Yamashita
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| | - Shiori Hino
- SEED Co., Ltd., 2-40-2 Hongo, Bunkyo-ku, Tokyo 113-8402, Japan; (S.H.); (T.M.)
| | - Toru Matsunaga
- SEED Co., Ltd., 2-40-2 Hongo, Bunkyo-ku, Tokyo 113-8402, Japan; (S.H.); (T.M.)
| | - Kazuki Tajima
- Department of Small Animal Internal Medicine II, School of Veterinary Medicine, Kitasato University, 35-1 Higashi 23 ban-cho, Towada, Aomori 034-8628, Japan; (M.K.); (Y.O.); (D.O.); (R.K.); (Y.Y.); (K.T.)
| |
Collapse
|
26
|
Saliman NH, Maldonado-Codina C, Morgan PB. Effect of material and care system combination on subclinical inflammation of the ocular surface in soft contact lens wear. Cont Lens Anterior Eye 2021; 45:101489. [PMID: 34281726 DOI: 10.1016/j.clae.2021.101489] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 07/03/2021] [Accepted: 07/07/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE To investigate the ocular subclinical inflammatory response in two soft contact lens materials when used in combination with two different care systems ('solutions'). METHODS Fifteen established soft contact lens wearers wore each of two lenses: Acuvue® 2 (CH) and Acuvue® Oasys® (SiH) or no lenses in random sequence for one week. Two care systems were used: a peroxide system: Oxysept 1 Step® (P) for the right lens and Opti-Free® Replenish® (MPS) for the left lens. After one week of lens/no lens wear, in vivo confocal microscopy (IVCM) of corneal and conjunctival regions was carried out. Density of presumed dendritic cells (DC) and 'white spots' (WS) were quantified. Impression cytology of the bulbar and upper eyelid margin conjunctivae was carried out and samples were analysed for CD45+, CD3+ and CD11c+ cells. RESULTS The SiH + MPS combination showed a greater inflammatory response compared to SiH + P in seven out of 12 parameters investigated (p < 0.05). The remaining five were not statistically different between the two solutions. The converse was found for the CH lens, with four of the 12 parameters showing a greater response with the P solution compared to the MPS (p < 0.05). CONCLUSION This study suggests that the SiH lens investigated demonstrated an upregulated response when used with a MPS compared to a P solution whereas the converse is true for the CH lens which showed a reduced response when used with a MPS compared to a P solution. This finding aids in the understanding of the biological underpinnings of manifest corneal inflammatory events during contact lens wear.
Collapse
Affiliation(s)
- Noor Haziq Saliman
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom; Neuroscience and Ophthalmology, Institute of Inflammation and Ageing, College of Medical and Dental Sciences, University of Birmingham, Birmingham, United Kingdom; NIHR Surgical Reconstruction and Microbiology Research Centre, University Hospitals Birmingham NHS Foundation Trust, Birmingham, United Kingdom.
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
27
|
Chan VWY, Phan CM, Ngo W, Jones L. Lysozyme Deposition on Contact Lenses in an In Vitro Blink-Simulation Eye Model Versus a Static Vial Deposition Model. Eye Contact Lens 2021; 47:388-393. [PMID: 33840748 DOI: 10.1097/icl.0000000000000784] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/07/2021] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate active lysozyme deposition on daily disposable (DD) contact lenses (CL) using a novel in vitro blink model. METHODS Three conventional hydrogel DD CL materials (etafilcon A, omafilcon A, nelfilcon A) and three silicone hydrogel DD CL materials (delefilcon A, senofilcon A, somofilcon A) were tested. The device blink rate was set to 6 blinks/min with a tear flow rate of 1 μL/min using an artificial tear solution (ATS) containing lysozyme and other typical tear film components. After incubation at 2, 4, or 8 hr, lenses were removed, and lysozyme activity was measured. A separate experiment was conducted with lenses incubated in a static vial containing 480 μL of ATS. RESULTS Etafilcon A deposited significantly higher amounts of active lysozyme (402±102 μg/lens) than other lens materials after 8 hr (P<0.0001). Etafilcon A had a higher amount of active lysozyme using the blink model compared with the static vial (P=0.0435), whereas somofilcon A (P=0.0076) and senofilcon A (P=0.0019) had a higher amount of lysozyme activity in the vial compared with the blink model. CONCLUSION The blink model can be tuned to provide quantitative data that closely mimics ex vivo studies and can be used to model deposition of lysozyme on CL materials.
Collapse
Affiliation(s)
- Vivian W Y Chan
- Centre for Ocular Research and Education (CORE) (V.W.Y.C., C.-M.P., W.N., L.J.), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada ; and Centre for Eye and Vision Research (CEVR) (C.-M.P., W.N., L.J.), Hong Kong, China
| | | | | | | |
Collapse
|
28
|
Heynen M, Ng A, Martell E, Subbaraman LN, Jones L. Activity of Deposited Lysozyme on Contemporary Soft Contact Lenses Exposed to Differing Lens Care Systems. Clin Ophthalmol 2021; 15:1727-1733. [PMID: 33935489 PMCID: PMC8079347 DOI: 10.2147/opth.s296116] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/17/2021] [Indexed: 11/23/2022] Open
Abstract
Purpose The amount of protein deposition on soft contact lenses and to what extent the proteins are denatured may have an impact on comfortable wearing times of contact lenses. The purpose of this study was to evaluate the effects of two lens care systems on total protein and the quantity and activity of lysozyme deposited on worn senofilcon A, silicone hydrogel contact lenses. Participants and Methods Thirty symptomatic soft contact lens wearers were enrolled into a 4-week prospective, randomized, bilateral eye, daily-wear, crossover, double-masked study. Participants were fitted with biweekly senofilcon A lenses and were assigned either a polyquaternium-1 and myristamidopropyl dimethylamine-containing system (OPTI-FREE RepleniSH) or a peroxide-based system (CLEAR CARE). After each wear period, proteins were extracted from the lenses and analyzed for total protein, total lysozyme quantity and activity. Results The use of either the peroxide-based system or the polyquaternium-1 and myristamidopropyl dimethylamine-containing system resulted in no difference (P>0.05) to the amount of total protein deposited on the lenses (6.7 ± 2.8 micrograms/lens versus 7.3 ± 2.8 micrograms/lens, respectively) or to the amount of denatured lysozyme deposits (0.8 ± 0.7 versus 0.9 ± 0.7 micrograms/lens), respectively. The total amount of lysozyme deposited on the lenses was significantly lower when using the peroxide-based system (1.3 ± 0.9 micrograms/lens) compared to the polyquaternium-1 and myristamidopropyl dimethylamine-containing system (1.7 ± 1.0 micrograms/lens) (P=0.02). Conclusion The inactivation of lysozyme deposited on senofilcon A lenses when disinfected with the peroxide-based or the polyquaternium-1 and myristamidopropyl dimethylamine-containing systems were neither statistically nor clinically significant and the overall amounts of denatured lysozyme recovered from the lenses were low (<1 microgram/lens).
Collapse
Affiliation(s)
- Miriam Heynen
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Alan Ng
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Elizabeth Martell
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | - Lyndon Jones
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.,Centre for Eye and Vision Research (CEVR), Hong Kong Science Park, Hong Kong
| |
Collapse
|
29
|
Efron N. Contact lens wear is intrinsically inflammatory. Clin Exp Optom 2021; 100:3-19. [DOI: 10.1111/cxo.12487] [Citation(s) in RCA: 56] [Impact Index Per Article: 18.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2016] [Revised: 05/07/2016] [Accepted: 06/09/2016] [Indexed: 11/28/2022] Open
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia,
| |
Collapse
|
30
|
Efron N, Morgan PB. Rethinking contact lens aftercare. Clin Exp Optom 2021; 100:411-431. [DOI: 10.1111/cxo.12588] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Revised: 05/10/2017] [Accepted: 05/21/2017] [Indexed: 11/28/2022] Open
Affiliation(s)
- Nathan Efron
- School of Optometry and Vision Science,Queensland University of Technology, Kelvin Grove, Queensland, Australia,
| | - Philip B Morgan
- Eurolens Research,The University of Manchester, Manchester, UK,
| |
Collapse
|
31
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
32
|
Mimura T, Fujishima H, Uchio E, Fukagawa K, Kawashima M, Kitsu K, Horikawa H, Mizota A. Adhesion of Pollen Particles to Daily Disposable Soft Contact Lenses. CLINICAL OPTOMETRY 2021; 13:93-101. [PMID: 33790684 PMCID: PMC8007601 DOI: 10.2147/opto.s297531] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 02/13/2021] [Indexed: 06/12/2023]
Abstract
PURPOSE Pollen and proteins attached to soft contact lenses (SCLs) exacerbate allergic conjunctivitis. The material of SCLs may affect the pollen adhesion to the SCLs. The factors associated with the number of pollen particles that are adherent to daily disposable SCL were investigated. METHODS Pollen particles were experimentally exposed to the contact lens surface of 12 types of SCLs for 1 hour, and the SCLs were washed and rinsed with a physiological saline (n=10 for each SCL type). A total of 120 contact lenses were used in this study. The pollen particles attached to the SCL were observed and photographed under a microscope. The influence of the materials of the SCLs on the degree of pollen adhesion were investigated. RESULTS The number of residual pollen particles attached to SCLs was in the range from 0-293/area of 200×200 µm. Percentage of pollen adhesion area of the surface of the SCL was in the range from 0.01% to 3.25%. There were significant differences in both the number and adhesion area of pollen particles among the 12 types of SCLs tested (P<0.0001 and P<0.0001, respectively). The number of pollen particles adhered to SCLs was significantly higher in colored SCLs than clear SCLs (unpaired t-test, p<0.001). The portion of pollen adhesion area was the lowest in the silicone hydrogel SCLs made with delefilcon-A (0.01 ± 0.02%). CONCLUSION Pollen adhesion in daily disposable SCLs depends on the characteristics and materials of the SCLs and was high in colored SCLs and lowest in delefilcon-A silicone hydrogel SCL. These results suggest that colored SCLs are not preferred during pollen season.
Collapse
Affiliation(s)
- Tatsuya Mimura
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Hiroshi Fujishima
- Department of Ophthalmology, Tsurumi University School of Dental Medicine, Yokohama, Kanagawa, Japan
| | - Eiichi Uchio
- Department of Ophthalmology, Fukuoka University School of Medicine, Fukuoka, Japan
| | - Kazumi Fukagawa
- Ryogoku Eye Clinic, Tokyo, Japan
- Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan
| | - Makoto Kawashima
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Kazuma Kitsu
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Hiroaki Horikawa
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| | - Atsushi Mizota
- Department of Ophthalmology, Teikyo University School of Medicine, Tokyo, Japan
| |
Collapse
|
33
|
Diken Gür S, Bakhshpour M, Bereli N, Denizli A. Antibacterial effect against both Gram-positive and Gram-negative bacteria via lysozyme imprinted cryogel membranes. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2021; 32:1024-1039. [PMID: 33704023 DOI: 10.1080/09205063.2021.1892472] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The development of novel biocompatible and cost effective cryogel membrane which shows enhanced antimicrobial properties in order to use for several approaches such as wound dressing, scaffold or food packaging was aimed in this study. A super macro porous lysozyme imprinted cryogel membranes showing antibacterial effect against both Gram-positive and Gram-negative bacteria were prepared by using molecular imprinting technique. N-methacryloyl-(L)-histidine methyl ester (MAH) was used as the pseudo specific ligand and complexed with Cu++ in order to provide metal ion coordination between MAH and template molecule (lysozyme). Comparing the antibacterial activity of different lysozyme concentrations, cryogel membranes were prepared in three different concentrations. To synthesize Poly (hydroxyethyl methacrylate-N-methacryloyl-(L)-histidine methylester) P(HEMA-MAH) cryogel membrane, free radical polymerization initiated by N, N, N', N'-tetramethylene diamine (TEMED) and ammonium persulfate (APS) was carried out at -12 °C. The characterization of the lysozyme imprinted cryogel membrane was accomplished by using scanning electron microscopy (SEM), swelling degree measurements and Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR) spectroscopy. The cytotoxicity test of produced membrane was performed by using mouse fibroblast cell line L929. The antibacterial activity of P(HEMA-MAH) lysozyme molecular imprinted [P(HEMA-MAH) Lyz-MIP] cryogel membranes against Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) were determined by Kirby-Bauer membranes diffusion and viable cell counting methods. When the antibacterial effect of P(HEMA-MAH) Lyz-MIP cryogel membranes were evaluated, it was found that P(HEMA-MAH) Lyz-MIP cryogel membranes had stronger antibacterial effects against Gram-negative E. coli bacteria even in low lysozyme concentrations. In addition, 100% bacterial inhibition was detected for both of two bacteria at increasing lysozyme concentrations.
Collapse
Affiliation(s)
| | | | - Nilay Bereli
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| | - Adil Denizli
- Department of Chemistry, Hacettepe University, Ankara, Turkey
| |
Collapse
|
34
|
Phan CM, Qiao H, Yee A, Jones L. Deposition of Fluorescently Tagged Lysozyme on Contact Lenses in a Physiological Blink Model. Eye Contact Lens 2021; 47:127-133. [PMID: 31789754 DOI: 10.1097/icl.0000000000000683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/02/2019] [Indexed: 11/25/2022]
Abstract
PURPOSE To visualize the deposition of fluorescein isothiocyanate (FITC) lysozyme on daily disposable contact lenses (CLs) using a novel blink model. METHODS Three daily disposable conventional hydrogel CLs (etafilcon A, omafilcon A, and nelfilcon A) and three silicone hydrogel CLs (delefilcon A, senofilcon A, and somofilcon A) were evaluated in the study. The CLs were mounted onto a novel blink model and exposed to an artificial tear solution containing FITC lysozyme for 2 and 10 hr. The flow rate and blink speed were set to 1 μL/min and 6 blinks/min, respectively. After the incubation period, a 5-mm-diameter disc was punched out from the center of the lens and mounted on a microscope slide. The slides were imaged using the Zeiss 510 Meta confocal laser scanning microscope, which scanned the lens from the front to the back surface at 5-μm increments. RESULTS There was an increase in deposition of FITC lysozyme for all lens types with increasing incubation time (P<0.05), with the exception of somofilcon A, which did not show statistical significance between 2 and 10 hr (P>0.05). The conventional hydrogel CLs deposited higher amounts of FITC lysozyme than the silicone hydrogel CLs (P<0.001), with etafilcon A depositing the highest at all time points (P<0.05). Interestingly, at the 2-hr incubation time, most CLs showed a higher amount of deposition at the front surface than the back surface of the lens. In particular, etafilcon A showed preferred deposition at the front surface at all time points. CONCLUSION The results suggest that there is differential deposition at the front surface of the CL, which is exposed to the prelens tear film, compared with the back surface of the CL, which is exposed to the postlens tear film. Therefore, it may be beneficial to design CL materials with differing surface properties for the front and back surfaces of the CL to enhance interactions with the tear film and ocular surface.
Collapse
Affiliation(s)
- Chau-Minh Phan
- Centre for Ocular Research and Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada
| | | | | | | |
Collapse
|
35
|
Fouling in ocular devices: implications for drug delivery, bioactive surface immobilization, and biomaterial design. Drug Deliv Transl Res 2021; 11:1903-1923. [PMID: 33454927 DOI: 10.1007/s13346-020-00879-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2020] [Indexed: 10/22/2022]
Abstract
The last 30 years has seen a proliferation of research on protein-resistant biomaterials targeted at designing bio-inert surfaces, which are prerequisite for optimal performance of implantable devices that contact biological fluids and tissues. These efforts have only been able to yield minimal results, and hence, the ideal anti-fouling biomaterial has remained elusive. Some studies have yielded biomaterials with a reduced fouling index among which high molecular weight polyethylene glycols have remained dominant. Interestingly, the field of implantable ocular devices has not experienced an outflow of research in this area, possibly due to the assumption that biomaterials tested in other body fluids can be translated for application in the ocular space. Unfortunately, progression in the molecular understanding of many ocular conditions has brought to the fore the need for treatment options that necessitates the use of anti-fouling biomaterials. From the earliest implanted horsehair and silk seton for glaucoma drainage to the recent mini telescopes for sight recovery, this review provides a concise incursion into the gradual evolution of biomaterials for the design of implantable ocular devices as well as approaches used to overcome the challenges with fouling. The implication of fouling for drug delivery, the design of immune-responsive biomaterials, as well as advanced surface immobilization approaches to support the overall performance of implantable ocular devices are also reviewed.
Collapse
|
36
|
Reduction of Physical Strength and Enhancement of Anti-Protein and Anti-Lipid Adsorption Abilities of Contact Lenses by Adding 2-Methacryloyloxyethyl Phosphorylcholine. Macromol Res 2020. [DOI: 10.1007/s13233-020-8149-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
37
|
Giant papillary conjunctivitis: A review. Ocul Surf 2020; 18:396-402. [DOI: 10.1016/j.jtos.2020.03.007] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2020] [Accepted: 03/29/2020] [Indexed: 11/23/2022]
|
38
|
Omali NB, Subbaraman LN, Heynen M, Lada M, Canavan K, Fadli Z, Ngo W, Jones L. Lipid deposition on contact lenses in symptomatic and asymptomatic contact lens wearers. Cont Lens Anterior Eye 2020; 44:56-61. [PMID: 32466858 DOI: 10.1016/j.clae.2020.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 05/08/2020] [Accepted: 05/11/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE Lipid deposition on contact lenses (CL) has traditionally been believed to reduce comfort during CL wear. The purpose of this study was to quantify lipid deposition on CL in a group of symptomatic and asymptomatic adapted CL wearers. METHODS This was a single-masked, randomized clinical trial. Only confirmed symptomatic (comfortable lens wear time (CWT) < 8 h and a noticeable reduction in comfort over the course of the day) and asymptomatic (CWT > 10 h and minimal reduction in comfort over the course of the day) participants were recruited to participate in the study. Participants wore senofilcon A lenses in combination with a polyquaternium-based care solution (OPTI-FREE Replenish). Worn CL samples were collected on Day 14. Deposited lipid amounts from the lenses (including cholesteryl ester, cholesterol and triolein) were quantified using a liquid chromatography-mass spectrometry technique. RESULTS Lipid deposition was significantly higher in CL extracts of asymptomatic wearers compared to the symptomatic wearers for all lipid types quantified, including cholesteryl ester (2.1 ± 0.6 vs 1.6 ± 0.5 log μg/lens), cholesterol (1.5 ± 0.3 vs 1.1 ± 0.3 log μg/lens) and triolein (0.3 ± 0.2 vs 0.1 ± 0.1 log μg/lens) (all p < 0.002). The amount of cholesteryl ester deposited was greatest (p = 0.0001), followed by cholesterol, then triolein, for both the asymptomatic and symptomatic groups (both p = 0.0001). CONCLUSION This study demonstrated that the asymptomatic group deposited a significantly greater amount of lipid on their CL. Although lipid levels measured are considered low to trigger any observable clinical deposition, they may influence other clinical outcomes, particularly comfort.
Collapse
Affiliation(s)
- Negar Babaei Omali
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Miriam Heynen
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| | - Mark Lada
- Johnson and Johnson Vision, Jacksonville, USA
| | | | - Zohra Fadli
- Johnson and Johnson Vision, Jacksonville, USA
| | - William Ngo
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada.
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
39
|
Burgener K, Bhamla MS. A polymer-based technique to remove pollutants from soft contact lenses. Cont Lens Anterior Eye 2020; 44:101335. [PMID: 32444249 DOI: 10.1016/j.clae.2020.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 05/07/2020] [Accepted: 05/10/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE To demonstrate an alternative to the rinse and rub (RR) method for cleaning pollutants from the exterior surface of soft contact lenses. This proposed technique is termed Polymer on Polymer Pollutant Removal (PoPPR), which utilizes the elastic properties of polydimethylsiloxane (PDMS) to physically remove contaminants from contact lens surfaces through non-adhesive unpeeling. METHODS Three different ratios of setting agent to polymer PDMS (1:30, 1:40, and 1:50) were evaluated using the PoPPR method against the control method of RR with a commercial multi-purpose lens cleaning solution. Three simulated pollutants of different sizes: pollen (25-40 μm), microbeads (1-5 μm), and nanoparticles (5-10 nm), were used to test the effectiveness of both cleaning methods. The fraction of pollutants removed from each contact lens was recorded and evaluated for significance. RESULTS PDMS 1:40 was found to be the optimal ratio for lens cleaning using the PoPPR method. For larger particles (>10 μm), no difference was observed between conventional RR and proposed PoPPR method (p > 0.05). However, the new PoPPR technique was significantly better at removing small PM2.5 particles (<2.5 μm) compared to the RR method, specifically for microbeads (p = 0.006) and nanoparticles (p < 0.001). CONCLUSION This proof-of-concept work demonstrates that the PoPPR method of cleaning contact lenses is as effective as the conventional cleaning method for larger particles such as pollen. The PoPPR method is more effective at removing extremely fine particulate pollutants, including microplastics and nanoparticles. This method offers a potentially more efficient cleaning protocol that could enhance the safety, health, and comfort of contact lens users, especially those living in regions with significant air pollution.
Collapse
Affiliation(s)
- Katherine Burgener
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, United States
| | - M Saad Bhamla
- School of Chemical and Biomolecular Engineering, Georgia Institute of Technology, Atlanta, GA, United States.
| |
Collapse
|
40
|
Ballard Z, Bazargan S, Jung D, Sathianathan S, Clemens A, Shir D, Al-Hashimi S, Ozcan A. Contact lens-based lysozyme detection in tear using a mobile sensor. LAB ON A CHIP 2020; 20:1493-1502. [PMID: 32227027 PMCID: PMC7189769 DOI: 10.1039/c9lc01039d] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We report a method for sensing analytes in tear-fluid using commercial contact lenses (CLs) as sample collectors for subsequent analysis with a cost-effective and field-portable reader. In this study we quantify lysozyme, the most prevalent protein in tear fluid, non-specifically bound to CLs worn by human participants. Our mobile reader uses time-lapse imaging to capture an increasing fluorescent signal in a standard well-plate, the rate-of-change of which is used to indirectly infer lysozyme concentration through the use of a standard curve. We empirically determined the best-suited CL material for our sampling procedure and assay, and subsequently monitored the lysozyme levels of nine healthy human participants over a two-week period. Of these participants who were regular CL wearers (6 out of 9), we observed an increase in lysozyme levels from 6.89 ± 2.02 μg mL-1 to 10.72 ± 3.22 μg mL-1 (mean ± SD) when inducing an instance of digital eye-strain by asking them to play a game on their mobile-phones during the CL wear-duration. We also observed a lower mean lysozyme concentration (2.43 ± 1.66 μg mL-1) in a patient cohort with dry eye disease (DED) as compared to the average monitoring level of healthy (no DED) human participants (6.89 ± 2.02 μg mL-1). Taken together, this study demonstrates tear-fluid analysis with simple and non-invasive sampling steps along with a rapid, easy-to-use, and cost-effective measurement system, ultimately indicating physiological differences in human participants. We believe this method could be used in future tear-fluid studies, even supporting multiplexed detection of a panel of tear biomarkers toward improved diagnostics and prognostics as well as personalized mobile-health applications.
Collapse
Affiliation(s)
- Zachary Ballard
- Department of Electrical and Computer Engineering, University of California, Los Angeles, USA.
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Efron N, Brennan NA, Chalmers RL, Jones L, Lau C, Morgan PB, Nichols JJ, Szczotka-Flynn LB, Willcox MD. Thirty years of 'quiet eye' with etafilcon A contact lenses. Cont Lens Anterior Eye 2020; 43:285-297. [PMID: 32278644 DOI: 10.1016/j.clae.2020.03.015] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/27/2020] [Accepted: 03/28/2020] [Indexed: 11/17/2022]
Abstract
Frequent replacement contact lenses made from the etafilcon A hydrogel lens material were introduced onto the market over 30 years ago, and etafilcon A remains the most widely used hydrogel lens material today. Although the prescribing of silicone hydrogel lenses is increasing, millions of lens wearers globally have been wearing hydrogel lenses for many years and exhibit a physiologically-stable 'quiet eye', with a low profile of adverse events. Hydrogel lenses are demonstrated to maintain a low inflammatory response and infection risk profile during daily wear, which in the case of etafilcon A, may be related to its low modulus, and the naturally-protective, anti-microbial, non-denatured lysozyme absorbed into the lens from the tear fluid. Although improved corneal physiology from decreased hypoxia with silicone hydrogel lenses is well accepted, equivalent levels of corneal oxygenation are maintained during daily wear of low to medium powered hydrogel lenses, which do not impede the daily corneal de-swelling process, and do not induce clinically significant changes in ocular health. Therefore, hydrogel lenses remain an important alternative for daily wear in modern contact lens practice.
Collapse
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | | | | | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada
| | - Charis Lau
- Johnson & Johnson Vision, Inc, Jacksonville, FL, USA
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, UK
| | - Jason J Nichols
- The University of Alabama at Birmingham, School of Optometry, Birmingham, AL, USA
| | - Loretta B Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Department of Ophthalmology & Visual Sciences, Case Western Reserve University, Cleveland, OH, USA
| | - Mark D Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
42
|
Sulley A, Dumbleton K. Silicone hydrogel daily disposable benefits: The evidence. Cont Lens Anterior Eye 2020; 43:298-307. [PMID: 32098715 DOI: 10.1016/j.clae.2020.02.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/18/2020] [Accepted: 02/12/2020] [Indexed: 10/24/2022]
Abstract
Daily disposable (DD) contact lenses first came to the market approximately 25 years ago and eye care professionals (ECPs) started prescribing silicone hydrogel (SiH) contact lenses, primarily for extended or continuous wear, approximately 20 years ago. It has now been over ten years since SiH DD contact lenses have been available, and while SiH materials are routinely prescribed by ECPs for reusable daily wear, hydrogel materials are still frequently selected for the DD modality of contact lens wear. This article reviews the evidence to support the benefits of both a DD modality and SiH materials and how patients' needs may be met with SiH DD contact lenses, with respect to clinical performance, health outcomes, satisfaction, compliance and convenience. Factors which may enable or constrain ECPs from prescribing SiH DD contact lenses, as opposed to hydrogel DD and reusable contact lenses, for more of their patients are discussed with the objective of providing ECPs with a greater understanding of the advantages that can be afforded by prescribing SiH DD contact lenses to both their new and existing contact lens wearers.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- Clinical Research Scientist and Consultant, Berkeley, CA, USA; Associate Clinical Professor, School of Optometry, University of California Berkeley, CA, USA.
| |
Collapse
|
43
|
Dogan C, Bahar Tokman H, Mergen B, Arslan OS, Iskeleli G. Effect of scleral lens use on conjunctival microbiota. Cont Lens Anterior Eye 2019; 43:189-191. [PMID: 31744671 DOI: 10.1016/j.clae.2019.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 09/21/2019] [Accepted: 11/01/2019] [Indexed: 10/25/2022]
Abstract
AIM This study aimed to investigate the effect of scleral lens (SL) use on conjunctival microbiota. METHOD A total of 26 eyes of 26 patients using an SL and 25 eyes of 25 healthy controls were included in the study. The samples were obtained from the lower fornices of the eyes using sterile swabs. For the bacteriological examination, a bacterial culture was obtained by inoculating the samples on chocolate agar, blood agar, MacConkey agar, and fluid thioglycollate medium. After 24-48 h of incubation at 37 0C, the growth of different colonies of bacteria was identified using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (Bruker MALDI Biotyper). RESULTS The mean age of the study group was 41.6 ± 19.1 years (18-65); the mean age of the control group was 40 ± 6 (21-62) (p = 0.69). There were 10 male patients and 16 female patients in the study group and 9 male patients and 16 female patients in the control group (p = 0.86). The mean duration of SL use was 13.7 ± 13.4 months (1-42 months). No bacterial growth was observed in 17 (65.4 %) of the 26 eyes in the SL group and 5 (20 %) of the 25 eyes in the control group (p = 0.001). The most commonly observed microorganisms were Staphylococcus epidermidis (S.epidermidis) and Staphylococcus aureus (S.aureus) in both groups. CONCLUSION SL users were found to have a higher rate of culture negativity in comparison to the healthy controls, suggesting that SLs have a significant effect on conjunctival microbiota.
Collapse
Affiliation(s)
- Cezmi Dogan
- Department of Ophthalmology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey.
| | - Hrisi Bahar Tokman
- Department of Medical Microbiology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Burak Mergen
- Department of Ophthalmology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Osman Sevki Arslan
- Department of Ophthalmology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| | - Guzin Iskeleli
- Department of Ophthalmology, Cerrahpasa Medical Faculty, Istanbul University-Cerrahpasa, Istanbul, Turkey
| |
Collapse
|
44
|
Moringo NA, Bishop LDC, Shen H, Misiura A, Carrejo NC, Baiyasi R, Wang W, Ye F, Robinson JT, Landes CF. A mechanistic examination of salting out in protein-polymer membrane interactions. Proc Natl Acad Sci U S A 2019; 116:22938-22945. [PMID: 31659038 PMCID: PMC6859367 DOI: 10.1073/pnas.1909860116] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Developing a mechanistic understanding of protein dynamics and conformational changes at polymer interfaces is critical for a range of processes including industrial protein separations. Salting out is one example of a procedure that is ubiquitous in protein separations yet is optimized empirically because there is no mechanistic description of the underlying interactions that would allow predictive modeling. Here, we investigate peak narrowing in a model transferrin-nylon system under salting out conditions using a combination of single-molecule tracking and ensemble separations. Distinct surface transport modes and protein conformational changes at the negatively charged nylon interface are quantified as a function of salt concentration. Single-molecule kinetics relate macroscale improvements in chromatographic peak broadening with microscale distributions of surface interaction mechanisms such as continuous-time random walks and simple adsorption-desorption. Monte Carlo simulations underpinned by the stochastic theory of chromatography are performed using kinetic data extracted from single-molecule observations. Simulations agree with experiment, revealing a decrease in peak broadening as the salt concentration increases. The results suggest that chemical modifications to membranes that decrease the probability of surface random walks could reduce peak broadening in full-scale protein separations. More broadly, this work represents a proof of concept for combining single-molecule experiments and a mechanistic theory to improve costly and time-consuming empirical methods of optimization.
Collapse
Affiliation(s)
| | | | - Hao Shen
- Department of Chemistry, Rice University, Houston, TX 77251
| | | | | | - Rashad Baiyasi
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77251
| | - Wenxiao Wang
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77251
| | - Fan Ye
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77251
| | - Jacob T Robinson
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77251
- Department of Bioengineering, Rice University, Houston, TX 77251
| | - Christy F Landes
- Department of Chemistry, Rice University, Houston, TX 77251;
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77251
- Smalley-Curl Institute, Rice University, Houston, TX 77251
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX 77251
| |
Collapse
|
45
|
Colciago S, Picarazzi S, Lecchi M, D'Arienzo M, Tavazzi S, Zeri F. Zeta potential of tear samples: A tool to explore the effects of wear of contact lenses. Cont Lens Anterior Eye 2019; 42:487-491. [PMID: 31519352 DOI: 10.1016/j.clae.2019.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 06/14/2019] [Accepted: 06/17/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE The aim was to develop a method to assess the electrostatic properties of human tear samples, and to evaluate their modifications induced by the wear of contact lenses (CLs). METHOD The barrier method was developed for the measurement of the isoelectric point (IEP) on relatively small quantities. The method was applied to compare three groups: tears (TNW) of non-wearers, tears (TW_etaf) of regular wearers of etafilcon A CLs, and tears (TW_omaf) of regular wearers of omafilcon A CLs. Zeta potential (ζ) as a function of pH was measured by a Zetasizer Nano ZS90 (Malvern Instruments) on 40%-diluted samples, obtained by mixing 57 μL of tears of different subjects of the same group with 85 μL of HCl aqueous solution. IEP was deduced as the pH at which ζ is zero, i.e. the net electric charge on tear constituents being neutralized. RESULTS Within an error of about 0.05, IEPs were found to be 2.90 (TNW), 2.80 (TW_omaf), and 3.16 (TW_etaf). On average, a lower H+ concentration is needed to neutralize the surface charge of the tear components of etafilcon A wearers, compared to both TNW and TW_omaf. CONCLUSION IEP measurements on tear samples of wearers of different types of CLs are proposed in order to enhance the knowledge on the modifications of the profile of charged species in tears. The TW_etaf results, compared to those of the other groups, are compatible with an increase, due to the wear of etafilcon A CLs, of the relative concentration of high-IEP proteins.
Collapse
Affiliation(s)
- Sara Colciago
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy
| | - Sara Picarazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy
| | - Marzia Lecchi
- University of Milano Bicocca, Department of Biotechnology and Bioscience, Piazza della Scienza 2, I-20126 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy
| | - Massimiliano D'Arienzo
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy.
| | - Fabrizio Zeri
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy; School of Life & Health Sciences, Aston University, Aston Triangle, Birmingham, B4 7ET, UK
| |
Collapse
|
46
|
Longo GS, Pérez-Chávez NA, Szleifer I. How protonation modulates the interaction between proteins and pH-responsive hydrogel films. Curr Opin Colloid Interface Sci 2019. [DOI: 10.1016/j.cocis.2018.11.009] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
47
|
Yang X, Zhang Y, Lai W, Xiang Z, Tu B, Li D, Nan X, Chen C, Hu Z, Fang Q. Proteomic profiling of RAW264.7 macrophage cells exposed to graphene oxide: insights into acute cellular responses. Nanotoxicology 2019; 13:35-49. [DOI: 10.1080/17435390.2018.1530389] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Xiaoliang Yang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Yan Zhang
- Central laboratory, Beijing Luhe Hospital, Capital Medical University, Beijing, China
| | - Wenjia Lai
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Zhichu Xiang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
- Sino-Danish Center for Education and Research, Beijing, China
| | - Bin Tu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Dan Li
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Xiaohui Nan
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
| | - Chunying Chen
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
- Sino-Danish Center for Education and Research, Beijing, China
| | - Zhiyuan Hu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
- Sino-Danish Center for Education and Research, Beijing, China
| | - Qiaojun Fang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials & Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology, Beijing, China
- Beijing Key Laboratory of Ambient Particles Health Effects and Prevention Techniques, National Center for Nanoscience and Technology, Beijing, China
- University of Chinese Academy of Sciences, Beijing, China
- Sino-Danish Center for Education and Research, Beijing, China
| |
Collapse
|
48
|
Walther H, Subbaraman LN, Jones L. Novel in vitro method to determine pre-lens tear break-up time of hydrogel and silicone hydrogel contact lenses. Cont Lens Anterior Eye 2018; 42:178-184. [PMID: 30442514 DOI: 10.1016/j.clae.2018.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2018] [Revised: 10/10/2018] [Accepted: 11/04/2018] [Indexed: 10/27/2022]
Abstract
PURPOSE To develop an in vitro model to determine pre-lens non-invasive break-up time (NIBUT) and to subsequently use this method to compare the NIBUT over contemporary daily disposable (DD) contact lenses (CL). METHODS Three silicone hydrogel (SH) and two conventional hydrogel (CH) DD CLs were incubated in an artificial tear solution (ATS). A model blink cell (MBC) was utilised to mimic intermittent air exposure. CLs were repeatedly submerged for 3 seconds (s) and exposed to air for 10 s over periods of 2, 6, 12, and 16 hours (h). NIBUTs (n = 4) were determined out of the blister pack (T0) and at the end of each incubation period. RESULTS Overall, nesofilcon A showed the longest NIBUTs (p < 0.001). At T0, CHs revealed significantly longer NIBUTs (p ≤ 0.001) than SHs. After 2 h, nesofilcon A showed the longest NIBUT, however, this was only statistically significant compared with delefilcon A (p ≤ 0.001). After 6 h, nesofilcon A NIBUT was significantly longer than all other CLs (p ≤ 0.001). Etafilcon A showed a significantly longer NIBUT (p ≤ 0.001) after 12 h and delefilcon A had the longest NIBUT (p ≤ 0.001) after 16 h. Statistically significant (p ≤ 0.05) changes of NIBUT within the lens materials varied between time points. After 16 h, all CLs showed significant reductions in NIBUTs (p ≤ 0.001) in comparison to T0. CONCLUSION NIBUT values reduced gradually over time and varying levels of deposition impacted measured pre-lens NIBUTs. While NIBUT of CH materials are longer immediately out of the blister pack, after tear film exposure, the NIBUTs obtained using this methodology became very similar.
Collapse
Affiliation(s)
- Hendrik Walther
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada.
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE, formerly CCLR), School of Optometry and Vision Science, 200 University Avenue West, Waterloo, ON, N2L 3G1, Canada
| |
Collapse
|
49
|
Hagemann A, Giussi JM, Longo GS. Use of pH Gradients in Responsive Polymer Hydrogels for the Separation and Localization of Proteins from Binary Mixtures. Macromolecules 2018. [DOI: 10.1021/acs.macromol.8b01876] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- Annika Hagemann
- Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| | - Juan M. Giussi
- Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| | - Gabriel S. Longo
- Instituto de Investigaciones Fisicoquímicas Teóricas y Aplicadas (INIFTA), UNLP-CONICET, La Plata, Argentina
| |
Collapse
|
50
|
Efficacy of Contact Lens Care Solutions in Removing Cholesterol Deposits From Silicone Hydrogel Contact Lenses. Eye Contact Lens 2018; 45:105-111. [PMID: 30199424 DOI: 10.1097/icl.0000000000000547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To determine the efficacy of multipurpose solutions (MPSs) on the removal of cholesterol deposits from silicone hydrogel (SH) contact lens materials using an in vitro model. MATERIALS AND METHODS Five SH lens materials: senofilcon A, comfilcon A, balafilcon A, lotrafilcon A, and lotrafilcon B were removed from the blister pack (n=4 for each lens type), incubated for 7 days at 37°C in an artificial tear solution containing C radiolabeled cholesterol. Thereafter, lenses were stored in a preserved saline solution control (Sensitive Eyes Saline Plus) or cleaned with 1 of the 5 MPSs incorporating different preservatives (POLYQUAD/ALDOX, polyquaternium-1/alexidine, polyquaternium-1/PHMB, and 2 based on PHMB alone) using a rub and rinse technique, according to the manufacturer's recommendations, and stored in the MPS for a minimum of 6 hr. Lenses were then extracted with 2:1 chloroform:methanol, analyzed in a beta counter, and μg/lens of cholesterol was determined. RESULTS Balafilcon A and senofilcon A lens materials showed the highest amounts of accumulated cholesterol (0.93±0.02 μg/lens; 0.95±0.01 μg/lens, respectively), whereas lotrafilcon A and lotrafilcon B deposited the lowest amounts (0.37±0.03 μg/lens; 0.47±0.12 μg/lens, respectively). For all lens materials, the MPS preserved with POLYQUAD/ALDOX removed more deposited cholesterol than any other test solution; however, the amount of removed cholesterol contamination from the individual contact lenses was only statistically significant for balafilcon A and senofilcon A (P=0.006 and P=0.042, respectively). Sensitive eyes and the other evaluated MPSs showed no significant effect on cholesterol removal (P>0.05). CONCLUSION Cholesterol-removal efficacy varies depending on the combination of lens material and solution. Only 1 MPS showed a statistically significant reduction of cholesterol deposit for only 2 of the 5 tested lens materials.
Collapse
|