Song H, Liu C, Yang W, Yang C, Cheng X. Comparison of central corneal thickness measured in myopic eyes by Pentacam, Sirius and IOLMaster 700. Photodiagnosis Photodyn Ther 2024; 49:104302. [PMID: 39134252 DOI: 10.1016/j.pdpdt.2024.104302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 07/24/2024] [Accepted: 08/05/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE The purpose of this study was to evaluate the correlations and consistency among the central corneal thickness (CCT) of healthy myopic patients measured with three different anterior segment analysis systems. DESIGN This was a retrospective study. The study included myopia patients who had undergone preoperative examinations in the refractive surgery department of our hospital between January 2021 and December 2023. The CCT was measured separately using Pentacam, Sirius, and IOLMaster 700. METHODS Statistical analysis was conducted using SPSS software. Correlations among the three groups of measured values were assessed using the Pearson method, and a simple scatter plot and fitting line were drawn. Bland‒Altman scatter plots and 95 % limits of agreement (LoAs) were used to evaluate consistency in the data among the systems. RESULTS A total of 269 patients participated in the study, including 134 males (49.8 %) and 135 females (50.2 %). The CCT measurements by Pentacam, Sirius, and IOLMaster 700 instruments were found to be 541.63 ± 31.67 μm, 541.74 ± 33.36 μm, and 548.90 ± 34.19 μm respectively; significant differences were observed among these measurements (p < 0.05). Significant differences were also observed in CCT between Pentacam and IOLMaster 700 as well as between Sirius and IOLMaster 700 (p < 0.05). The CCT measurements by all three devices showed high positive correlation with all p values less than 0.001: Pentacam and Sirius, r = 0.972; Pentacam and IOLMaster 700, r = 0.966; and Sirius and IOLMaster 700, r = 0.962. The respective 95 % LoAs were -0.18∼0.18; -1.51∼-1.11; and -1.52∼-1. CONCLUSION The results indicate that there is a high correlation in measuring CCT for healthy myopic eyes using three different anterior segment analysis systems. However, the differences in the values measured by the three devices were statistically significant. Therefore, in actual clinical practice, it is suggested that the same device should be used to measure and evaluate the CCT across visits.
Collapse
Affiliation(s)
- Han Song
- Harbin Bright Eye Hospital, Harbin, Heilongjiang, China
| | - Chengyang Liu
- Harbin Bright Eye Hospital, Harbin, Heilongjiang, China
| | - Wei Yang
- Harbin Bright Eye Hospital, Harbin, Heilongjiang, China
| | - Chunliu Yang
- Harbin Bright Eye Hospital, Harbin, Heilongjiang, China
| | - Xiaodong Cheng
- Heilongjiang Provincial Hospital, Harbin, Heilongjiang, China.
| |
Collapse
|
2
|
Baxter J, Atwan N. A Comparison Between Ultrasound Pachymetry and CASIA2 (Anterior-Segment Optical Coherence Tomography) in the Measurement of Central Corneal Thickness. Cureus 2023; 15:e39921. [PMID: 37409208 PMCID: PMC10317844 DOI: 10.7759/cureus.39921] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/01/2023] [Indexed: 07/07/2023] Open
Abstract
Background and objective Due in part to its effect on intraocular pressure (IOP) measurements, the assessment of central corneal thickness (CCT) is recognized as an essential part of the initial glaucoma assessment. The most widely utilized clinical technique to measure CCT is ultrasound pachymetry (USP). In recent years, many dedicated anterior-segment optical coherence tomography scanners (AS-OCTs) have been developed. Previous studies have compared CCT measurements between USP and various AS-OCTs. This study aimed to assess the degree of agreement between USP and CASIA2 (Tomey Corporation, Nagoya, Japan), a second-generation swept-source AS-OCT developed in Japan. Methodology The data on CCT screening measurements of 156 eyes (88 patients) performed over a period of three months, from January to March 2020, on glaucoma patients attending the Royal Hallamshire Hospital (RHH) in Sheffield, UK were collected retrospectively and statistically analyzed. Results The average age of the 88 patients included in the study was 66 years (range: 20-86 years). Our findings show that when compared to CASIA2 measurements, USP measurement of the CCT resulted in significantly thicker values (paired t-test: t=23.15,p<2.2 x 10-16). The average difference between the two methods was 19.98 ± 10.78 μm. It is hypothesized that this difference may be due in part to inaccurate probe placement during ultrasound probe measurement, resulting in thicker CCT values. Conclusion The observed difference may be clinically significant as it could induce clinical discrepancy in terms of perceived glaucoma risk in patients. Therefore, USP and CASIA2 should not be used interchangeably, and clinicians should take into account the significant difference between these methods.
Collapse
Affiliation(s)
- Joe Baxter
- Ophthalmology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, GBR
| | - Nadeem Atwan
- Ophthalmology, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, GBR
| |
Collapse
|
3
|
Kan E, Duran M, Yakar K. Comparison of central corneal thickness measurements using three different imaging devices. J Fr Ophtalmol 2023:S0181-5512(23)00037-2. [PMID: 37076388 DOI: 10.1016/j.jfo.2022.09.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2022] [Accepted: 09/12/2022] [Indexed: 04/21/2023]
Abstract
PURPOSE The purpose of this study was to compare central corneal thickness (CCT) values and evaluate the agreement obtained with three different devices in healthy eyes. METHODS A total of 120 eyes of 60 healthy individuals (36 men and 24 women) were enrolled in this retrospective study. CCT measurements were performed using an optical biometer (AL-Scan), spectral-domain optical coherence tomography (SD-OCT) (Topcon 3D) and ultrasonic pachymetry (UP) (Accupach VI), and the results were compared. Bland-Altman analysis was used to quantify the agreement between methods. MAIN RESULTS The mean patient age was 28±5.73years (18-40years). The mean CCT values obtained by AL-Scan, UP, and SD-OCT were 532.4μm±29.7, 549μm±30.4, and 547μm±30.6, respectively. The mean differences in CCT were 15.30±9.52μm between AL-Scan and OCT (P<0.01), 17.15±8.42μm between AL-Scan and UP (P<0.01), and 1.85± 8.78μm between UP and OCT (P=0.067). All three methods of CCT measurement were closely correlated with each other. CONCLUSION The present study results suggest that, despite good agreement between the three devices, AL-Scan significantly underestimated CCT compared to UP and OCT. Therefore, clinicians should be aware that different results can be obtained using different devices for CCT measurements. It would be a better approach not to use them as interchangeable in clinical practice. CCT examination and follow-up should be performed using the same device, especially for patients who will undergo refractive surgery.
Collapse
Affiliation(s)
- E Kan
- Medicana International Hospital, Department of Ophthalmology, Samsun, Turkey.
| | - M Duran
- Medicana International Hospital, Department of Ophthalmology, Samsun, Turkey
| | - K Yakar
- Medicana International Hospital, Department of Ophthalmology, Samsun, Turkey
| |
Collapse
|
4
|
Ulutas HG, Ozkaya G, Amuk Hamidi N. Comparison of central corneal thickness measured by ultrasound pachymetry, corneal topography, spectral domain- optical coherence tomography, and non-contact specular microscopy. Photodiagnosis Photodyn Ther 2023; 42:103527. [PMID: 36966866 DOI: 10.1016/j.pdpdt.2023.103527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 03/20/2023] [Accepted: 03/21/2023] [Indexed: 04/16/2023]
Abstract
BACKGROUND This study aims to investigate the compatibility of central corneal thickness (CCT) measurements obtained with spectral-domain optical coherence tomography (SD-OCT), Scheimpflug-Placido-based corneal topography (CT), non-contact specular microscopy (NCSM), and ultrasonic pachymetry (UP). These four corneal measurement techniques have not been compared in a single study on these many subjects. METHODS CCT was measured in 185 eyes of 185 volunteers with each of the four devices by a single observer. CCTs from Optovue® iVue SD-OCT, Sirius corneal topography, NonconRobo NCSM, and Accutom UP devices were recorded. Compatibility between devices was evaluated with intraclass correlation coefficient (ICC) and Bland-Altman plots. Pairwise comparisons were performed using the Bonferroni test. Measurement differences between devices were analyzed with the Pearson correlation coefficient. RESULTS Of the 185 volunteers, 103 were men, and 82 were women. Their mean age was 48.55 ± 16.6 (18-70) years. Mean CCT values measured by UP, CT, OCT, and NCSM were 546.77 ± 39.2, 535.29 ± 39.2, 526.49 ± 39.05, 505.15 ± 46.1 µm, respectively. Statistically significant differences were found between the mean CCT values obtained from the paired devices (p <0.001). The highest difference between pairs was found between UP and NCSM (43.63 ± 1.8 µm; CI 38.74 to 48.5 µm; p <0.001), while the lowest difference was found between OCT and CT (7.3 ± 1.5 µm; 95%CI 3.1 to 11.6 µm; p <0.001). In pairwise comparisons of four devices, the highest ICC value was between UP and CT (ICC: 0.899, 95%CI 0.759-0.947; p <0.001). CONCLUSION Despite the high correlation between measurements obtained from different methods, notable differences in CCT values exist, rendering devices non-interchangeable. Therefore, alternative brands of the same device may yield different outcomes.
Collapse
Affiliation(s)
- Hafize Gokben Ulutas
- Department of Ophthalmology, University of Health Sciences, Yuksek Ihtisas Training and Research Hospital, Bursa, Türkiye.
| | - Guven Ozkaya
- Department of Biostatistics, Bursa Uludag University, Faculty of Medicine, Bursa, Türkiye
| | - Nagihan Amuk Hamidi
- Department of Ophthalmology, University of Health Sciences, Yuksek Ihtisas Training and Research Hospital, Bursa, Türkiye
| |
Collapse
|
5
|
New Findings in Early-Stage Keratoconus: Lamina Cribrosa Curvature, Retinal Nerve Fiber Layer Thickness, and Vascular Perfusion. Am J Ophthalmol 2023; 246:122-129. [PMID: 36323392 DOI: 10.1016/j.ajo.2022.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 10/15/2022] [Accepted: 10/20/2022] [Indexed: 01/24/2023]
Abstract
PURPOSE Our aim was to investigate the involvement of posterior pole structures in eyes affected by keratoconus (KC). Optical coherence tomography (OCT) and OCT angiography (OCTA) were used to determine the status of lamina cribrosa (LC), peripapillary retinal nerve fiber layer (RNFL), macular and peripapillary microvasculature. DESIGN Observational, cross-sectional, case-control analysis. METHODS Single-center investigation involving patients with KC and healthy control subjects. Enrolled subjects underwent anterior segment OCT combined with Placido-disk topography, macular and optic nerve head swept-source OCT and swept-source OCTA scans, and 3D wide glaucoma module for peripapillary RNFL thickness measurement. The LC curvature index was used to express the degree of LC posterior bowing. We calculated the vessel density and vessel length density at the macular superficial capillary plexus, deep capillary plexus, choriocapillaris, and nerve radial peripapillary capillary plexus. RESULTS Overall, 32 eyes with KC and an equal number of age- and axial length-matched control eyes were included in the analysis. Almost all (97%) of eyes with KC were classified as early stage. KC displayed a reduction in peripapillary RNFL thickness (104.8 ± 11.9 µm vs 110.7 ± 10.5 µm; P = .039) and nerve radial peripapillary capillary plexus vessel density (46.31% ± 3% vs 43.82% ± 4%; P = .006) when compared with control subjects; these differences were more evident in the temporal sector and were associated with a higher LC curvature index (9.9% ± 2.6% vs 8.48% ± 1.7%; P = .012). Mean macular superficial capillary plexus vessel density was 3 percentage points lower in eyes with KC than in healthy controls (P < .001). CONCLUSION Early-stage KC may be characterized by a posterior bowing of the LC along with a subtle peripapillary RNFL thinning and vascular impairment. These findings support the hypothesis that KC may be a corneal manifestation of a more generalized "eye collagen disease."
Collapse
|
6
|
Muijzer MB, Noordmans HJ, Delbeke H, Dickman MM, Nuijts RMMA, Dunker S, Imhof SM, Wisse RPL. Establishing a Biomarker for the Prediction of Short-Term Graft Detachment After Descemet Membrane Endothelial Keratoplasty. Cornea 2023; 42:204-210. [PMID: 35184123 DOI: 10.1097/ico.0000000000003006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/03/2022] [Indexed: 01/03/2023]
Abstract
PURPOSE The purpose of this study was to investigate the predictive value of pachymetry mapping 1 day after Descemet membrane endothelial keratoplasty (DMEK) as a biomarker for early graft detachment. METHODS This was a post hoc analysis of 65 pseudophakic subjects with Fuchs endothelial dystrophy who underwent DMEK surgery between December 2018 and April 2021 as part of the Advanced Visualization In Corneal Surgery Evaluation international multicenter randomized controlled trial. One eye per patient was included. Preoperatively and 1 day postoperatively, patients underwent anterior segment optical coherence tomography imaging. Using a grid consisting of 25 zones (ie, pachymetry map), corneal thickness and presence of a graft detachment were mapped for each patient. Detachments of any size were considered, regardless of subsequent clinical interventions. Missing data were imputed and subsequently divided into a training and test set. Two prediction methods were evaluated: one model based on absolute corneal thickness and a regression model. RESULTS A total of 65 eyes were included for analysis of which 33 developed any form of graft detachment. Preoperatively, no significant differences were observed between the groups ( P = 0.221). Corneal thickness in the corneal zones with a detached graft was significantly increased compared with corneal zones with an attached graft ( P < 0.001). The regression prediction model had an area under the curve of 0.87 (sensitivity: 0.79 and specificity: 0.75), whereas the absolute thickness cutoff model only reached 0.65. CONCLUSIONS Pachymetry mapping 1 day after DMEK was predictive for early graft detachment, and the prediction model had a good to excellent performance. This aids in identifying patients at risk for graft detachment and subsequent tailored postoperative care.
Collapse
Affiliation(s)
- Marc B Muijzer
- Utrecht Cornea Research Group, Ophthalmology Department, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Herke-Jan Noordmans
- Medical Technical and Clinical Physics Department, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Heleen Delbeke
- Ophthalmology Department, University Hospital Leuven, Leuven, Belgium; and
| | - Mor M Dickman
- University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Rudy M M A Nuijts
- University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Suryan Dunker
- University Eye Clinic, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Saskia M Imhof
- Utrecht Cornea Research Group, Ophthalmology Department, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Robert P L Wisse
- Utrecht Cornea Research Group, Ophthalmology Department, University Medical Center Utrecht, Utrecht, the Netherlands
| |
Collapse
|
7
|
Thin Central Corneal Thickness May Be a Risk Factor for Myopia Progression in Children. J Ophthalmol 2023; 2023:3815863. [PMID: 36700116 PMCID: PMC9870691 DOI: 10.1155/2023/3815863] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/20/2022] [Accepted: 01/05/2023] [Indexed: 01/18/2023] Open
Abstract
Purpose This study investigated the correlation between corneal biomechanical parameters and the speed of myopia progression. Methods This is a retrospective, multicenter study. Both Chinese and Caucasian children were involved. The follow-up time was at least 12 months. Ocular biometry data including the central corneal thickness (CCT), axial length (AL), corneal keratometry (K), anterior chamber depth (ACD), white-to-white (WTW) distance, and pupil size (PS) were measured. The age of onset, speed of progression of spherical equivalent (SE), and speed of AL elongation were calculated. Data were analyzed using the R programming language. Results This study comprised 306 eyes of 153 myopic children. 122 children were Chinese, and 31 children were Caucasian. The myopia progression was faster in Chinese children than that in the Caucasian group in both SE progression speed and AL elongation speed. The CCT was negatively correlated with the SE speed of progression (correlation coefficient, R = -0.65, and p=7.25 × 10-38) and AL speed (R = -0.47 and p=1.62 × 10-18). CCT was positively correlated with the age of onset (R = 0.35 and p=4.53 × 10-10). No significant correlation (R > 0.3 and p < 0.01) was found between other ocular biometries (K, ACD, WTW, and PS) and the onset and speed of the progression of myopia. The same trends were found in both Chinese and Caucasian children and in both the right eye and left eye. Conclusion CCT was negatively correlated with myopia (SE) progression speed and AL elongation speed. Thin CCT may be associated with faster myopia progression.
Collapse
|
8
|
Corneal and Epithelial Thickness Mapping: Comparison of Swept-Source- and Spectral-Domain-Optical Coherence Tomography. J Ophthalmol 2021; 2021:3444083. [PMID: 34650817 PMCID: PMC8510821 DOI: 10.1155/2021/3444083] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2021] [Accepted: 09/23/2021] [Indexed: 11/17/2022] Open
Abstract
Objective To compare the results and repeatability of the corneal thickness (CT) and epithelial thickness (ET) maps provided by Enhanced Spectral-Domain-Optical Coherence Tomography with those of Spectral-Domain-OCT in normal eyes. Methods 30 normal eyes of 30 patients were assessed by 3 trained operators with ESD-OCT and SD-OCT. Results The central and minimum ET obtained with both devices were correlated: central ET, r = 0.86, p < 0.05; minimum ET, r = 0.72, p < 0.05. Compared with SD-OCT, ESD-OCT tended to underestimate these figures by 1.4 and 1.9 μm on average. The central and minimum CT obtained with both devices were strongly correlated: central CT, r = 0.994, p < 0.05; minimum CT, r = 0.995, p < 0.05. ESD-OCT tended to overestimate these figures by 11 and 14 μm on average. Repeatability was good for both devices with a mean coefficient of variation of measurements <6% for ET and <2% for CT. Interoperator variability (standard deviation and COV) was significantly higher for ESD-OCT than for SD-OCT for all local epithelial thicknesses and significantly lower for the central CT and several local corneal thicknesses, whereas no significant differences between both technologies were found for the central and minimum ET and the minimum CT. Conclusion ESD-OCT and SD-OCT provide reproducible measurements of CT and ET in normal corneas with a strong correlation between both technologies. However, both technologies are not interchangeable when the main thickness parameters (i.e., central and minimum CT and minimum ET) are used for diagnosing early keratoconus or calculating the expected residual stromal bed thickness before corneal refractive surgery or anterior lamellar keratoplasty.
Collapse
|
9
|
Jin Y, McAlinden C, Sun Y, Wen D, Wang Y, Yu J, Feng K, Song B, Wang Q, Chen S, Huang J. Sirius Scheimpflug-Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis. EYE AND VISION 2021; 8:5. [PMID: 33602345 PMCID: PMC7891160 DOI: 10.1186/s40662-021-00227-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Accepted: 01/13/2021] [Indexed: 11/26/2022]
Abstract
Background To compare the difference in central corneal thickness (CCT) measurements in normal eyes between a rotating Scheimpflug camera combined with a Placido-disk corneal topographer (Sirius, CSO, Italy) and ultrasound pachymetry (USP). Methods A systematic literature search was conducted for relevant studies published on PubMed, Medline, EMBASE, and the Cochrane Library and ClinicalTrials.gov from inception to August 1st, 2019. Primary outcome measures were CCT measurements between Sirius and USP. A random effects model was used to pool CCT measurements. Results A total of twelve studies involving 862 eyes were included in this meta-analysis. The meta-analysis found CCT measurements between Sirius and USP to be statistically significantly different (P < 0.0001). The mean difference between Sirius and USP was −11.26 μm with a 95% confidence interval (CI) (−16.92 μm, −5.60 μm). The heterogeneity was I2 = 60% (P = 0.004). Conclusion CCT measurements with the Sirius Scheimpflug-Placido topographer were statistically significantly lower than USP. However, it may be argued that the mean difference of 11.26 μm is not a clinically significant difference.
Collapse
Affiliation(s)
- Yili Jin
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Colm McAlinden
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.,Department of Ophthalmology, Singleton Hospital, Swansea Bay University Health Board, Swansea, UK
| | - Yong Sun
- Shenzhen Hospital of Integrated Traditional and Western Medicine, Shenzhen, China
| | - Daizong Wen
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Yiran Wang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Jinjin Yu
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Ke Feng
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Benhao Song
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Qinmei Wang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China.,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China
| | - Shihao Chen
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China. .,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China. .,Eye Hospital of Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, 325027, Zhejiang, China.
| | - Jinhai Huang
- School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China. .,Key Laboratory of Vision Science, Ministry of Health P.R. China, Wenzhou, Zhejiang, China. .,Eye Hospital of Wenzhou Medical University, 270 West Xueyuan Road, Wenzhou, 325027, Zhejiang, China.
| |
Collapse
|
10
|
Zhang XF, Li M, Shi Y, Wan XH, Wang HZ. Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation. Int J Ophthalmol 2020; 13:625-631. [PMID: 32399415 DOI: 10.18240/ijo.2020.04.15] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 07/11/2019] [Indexed: 12/27/2022] Open
Abstract
AIM To evaluate the intra-operator repeatability of time domain and swept-source Fourier domain anterior segment optical coherence tomography (AS-OCT), namely, Visante AS-OCT and Casia SS-1000 OCT, in measuring the preoperative parameters of implantable collamer lens (ICL) in myopic eyes, as well as the agreement between the two devices. METHODS A total of 97 eyes from 49 myopes were investigated in this prospective case series study. The anterior chamber depth (ACD), angle-to-angle distance (ATA), pupil diameter (PD) and crystalline lens rise (CLR) in all subjects were measured for three times during one session by the same operator. The repeatability was evaluated using the within-subject standard deviation (Sw), repeatability limits and intraclass correlation coefficients (ICC). The agreement between the two systems was evaluated using the Bland-Altman plots and 95% limits of agreement (LoA). RESULTS The repeatability limits of Visante AS-OCT in measuring ACD, ATA, PD and CLR were 0.099, 0.141, 0.304, and 0.079 mm, respectively. The repeatability limits of Casia SS-1000 OCT in measuring ACD, ATA, PD, and CLR were 0.105, 0.127, 0.357, and 0.082 mm, respectively. Excellent repeatability could be attained in both devices, with the ICC>0.8 for all the measured variables. The interdevice agreement was excellent (P>0.05) for ACD and ATA, but poor (P<0.05) for PD and CLR. CONCLUSION Good repeatability can be attained by time domain and swept-source Fourier-domain OCT for all the measured variables. Moreover, interdevice agreement analysis suggests that interchangeable measurements between two devices can be achieved for ACD and ATA, but not for PD and CLR; but the differences in measurements were not clinically significant.
Collapse
Affiliation(s)
- Xi-Fang Zhang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
| | - Meng Li
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
| | - Yan Shi
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
| | - Xiu-Hua Wan
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
| | - Huai-Zhou Wang
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Institute of Ophthalmology, Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing 100730, China
| |
Collapse
|
11
|
A Review of the Use of Confidence Intervals for Bland-Altman Limits of Agreement in Optometry and Vision Science. Optom Vis Sci 2020; 97:3-8. [PMID: 31895271 DOI: 10.1097/opx.0000000000001465] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Confidence intervals are still seldom reported for Bland-Altman 95% limits of agreement. When they are reported, 50% of articles use approximate methods and 50% use exact methods. PURPOSE Bland-Altman limits of agreement can be unreliable estimates, especially for small sample sizes. However, authors seldom use confidence intervals for limits of agreement. This article reviews their use in Optometry and Vision Science. METHODS A keyword search for "Bland," "Altman," "Bland-Altman," "LoA," and "limits of agreement" was conducted on the Optometry and Vision Science website within a time range from January 2016 to December 2018. RESULTS Fifty articles were reported or were judged to use Bland-Altman analysis; sample sizes ranged from 3 to 2072. Eight of these article reported confidence limits for limits of agreement, four of which used exact methods and four used Bland and Altman's approximate method. CONCLUSIONS Use of confidence intervals for limits of agreement has increased in Optometry and Vision Science but is far from universal. To assist researchers in calculating exact confidence limits for Bland-Altman limits of agreement, spreadsheets are included for performing the calculations and generating Bland-Altman plots with the confidence intervals included.
Collapse
|
12
|
Corneal oedema in a unilateral corneal graft patient induced by high Dk mini-scleral contact lens. Cont Lens Anterior Eye 2018; 41:458-462. [DOI: 10.1016/j.clae.2018.05.004] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 04/04/2018] [Accepted: 05/14/2018] [Indexed: 01/19/2023]
|
13
|
Vincent SJ, Alonso-Caneiro D, Collins MJ. Optical coherence tomography and scleral contact lenses: clinical and research applications. Clin Exp Optom 2018; 102:224-241. [PMID: 30062745 DOI: 10.1111/cxo.12814] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2018] [Revised: 06/20/2018] [Accepted: 06/24/2018] [Indexed: 12/30/2022] Open
Abstract
Anterior segment optical coherence tomography (OCT) provides a wealth of opportunities for modern contact lens practice. OCT imaging has numerous clinical and research applications related to the tear film, cornea, conjunctiva, sclera and ocular adnexae, in addition to soft, rigid, and hybrid contact lenses. This review summarises the potential use of OCT imaging in modern scleral contact lens practice including initial lens selection, assessing the scleral contact lens fit with respect to the cornea and sclera, and accurately quantifying the ocular response to lens wear. Recent advances in the understanding of anterior segment metrics including scleral thickness, curvature, toricity, and the anatomy of the corneoscleral limbal junction are also discussed.
Collapse
Affiliation(s)
- Stephen J Vincent
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Queensland, Australia
| | - David Alonso-Caneiro
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Michael J Collins
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Queensland, Australia
| |
Collapse
|
14
|
Gokcinar NB, Yumusak E, Ornek N, Yorubulut S, Onaran Z. Agreement and repeatability of central corneal thickness measurements by four different optical devices and an ultrasound pachymeter. Int Ophthalmol 2018; 39:1589-1598. [PMID: 29984376 DOI: 10.1007/s10792-018-0983-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Accepted: 06/26/2018] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the repeatability and agreement of central corneal thickness (CCT) measurements by spectral-domain optical coherence tomography (OCT), corneal topography (CT) with a combined Scheimpflug-Placido system, optical biometry (OB), specular microscopy (SM), and ultrasound pachymetry (UP). METHODS A single observer measured CCT twice in 150 eyes of 150 subjects with each of five devices: Nidek RS-3000 Advance OCT, CSO Sirius combined Scheimpflug-Placido disc system CT, Nidek AL-Scan partial coherence interferometry-based OB, Tomey EM-3000 SM, and Reichert iPac ultrasonic pachymeter. Pachymetry values corrected by the SM device software were also recorded. Levels of agreement between devices were evaluated by Bland-Altman plots with 95% limits of agreement, and repeatability for each device was analysed with intraclass correlation coefficients. RESULTS The mean CCTs measured by OCT, CT, OB, SM, corrected SM, and UP were 544.60 ± 29.56, 536.19 ± 32.14, 528.29 ± 29.45, 524.88 ± 32.38, 537.88 ± 32.38, and 545.29 ± 30.75 μm, respectively. Mean CCT differed significantly between the devices (p < 0.05) apart from between OCT and UP, and between CT and corrected SM. Mean paired differences between devices ranged between 0.68 and 20.41 μm. Repeatability with all devices was excellent (> 0.99). The range of limits of agreement was the least between OCT and UP. CONCLUSIONS Different CCT measurement techniques produce quite different results, so CCT evaluation and follow-up should be performed using the same device or devices with close compatibility.
Collapse
Affiliation(s)
- Nesrin Buyuktortop Gokcinar
- Department of Ophthalmology, Faculty of Medicine, Kırıkkale University Hospital, Yahşihan, Kırıkkale, Turkey.
| | - Erhan Yumusak
- Department of Ophthalmology, Faculty of Medicine, Kırıkkale University Hospital, Yahşihan, Kırıkkale, Turkey
| | - Nurgul Ornek
- Department of Ophthalmology, Faculty of Medicine, Kırıkkale University Hospital, Yahşihan, Kırıkkale, Turkey
| | - Serap Yorubulut
- Department of Statistics, Faculty of Science and Letters, Kırıkkale University, Kırıkkale, Turkey
| | - Zafer Onaran
- Department of Ophthalmology, Faculty of Medicine, Kırıkkale University Hospital, Yahşihan, Kırıkkale, Turkey
| |
Collapse
|
15
|
Repeatability and Intersession Reproducibility of Pentacam Corneal Thickness Maps in Fuchs Dystrophy and Endothelial Keratoplasty. Cornea 2018; 37:987-992. [PMID: 29781926 DOI: 10.1097/ico.0000000000001634] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess intrasession repeatability and intersession reproducibility of Pentacam corneal thickness maps in patients with Fuchs endothelial corneal dystrophy (FECD) before and after endothelial transplantation. METHODS In this observational diagnostic evaluation, 20 healthy subjects along with 81 consecutive patients were examined. Patients were classified into 4 groups: FECD without corneal edema, FECD with corneal edema, Descemet stripping automated endothelial keratoplasty, and Descemet membrane endothelial keratoplasty. Three consecutive scans of each eye were obtained at 2 different sessions. Raw pachymetry data were used to calculate average values of 4 concentric annular zones, which were also divided into 8 sectors. Repeatability and reproducibility coefficients (CR), coefficient of variation (CV), intraclass correlation coefficient, and 95% limits of agreement were calculated. RESULTS The intrasession repeatability CV was ≤1% in the central 6 mm for all groups, with an intraclass correlation coefficient ≥0.97. It was better at the central zone than the periphery in all groups. Intersession reproducibility tended to be worse in the central area than the periphery in FECD without edema (CR ≤ 24.37; CV ≤ 1.48) and FECD with edema (CR ≤ 36.74; CV ≤ 2.03), whereas it was better in the central area in healthy eyes (CR ≤ 20.11; CV ≤ 1.32) and improved after Descemet stripping automated endothelial keratoplasty (CR ≤ 21.93; CV ≤ 1.31) and Descemet membrane endothelial keratoplasty (CR ≤ 30.83; CV ≤ 1.94). CONCLUSIONS Pentacam corneal thickness maps showed good repeatability and intersession reproducibility in virgin and grafted corneas with FECD, which makes it a valid tool for monitoring these patients. Central areas showed the highest variability between sessions in diseased groups.
Collapse
|
16
|
Vincent SJ, Alonso-Caneiro D, Collins MJ. The temporal dynamics of miniscleral contact lenses: Central corneal clearance and centration. Cont Lens Anterior Eye 2018; 41:162-168. [DOI: 10.1016/j.clae.2017.07.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 06/29/2017] [Accepted: 07/04/2017] [Indexed: 01/12/2023]
|
17
|
Vincent SJ, Alonso-Caneiro D, Collins MJ. The time course and nature of corneal oedema during sealed miniscleral contact lens wear. Cont Lens Anterior Eye 2018; 42:49-54. [PMID: 29548929 DOI: 10.1016/j.clae.2018.03.001] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2017] [Revised: 02/22/2018] [Accepted: 03/06/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE To examine the magnitude and time course of central epithelial, stromal and total corneal thickness changes during sealed miniscleral contact lens wear and the influence of initial central corneal clearance upon these thickness changes. METHODS High-resolution OCT images were captured over an 8 h period of miniscleral contact lens wear (using a rotationally symmetric 16.5 mm diameter lens) in 15 young, healthy participants with normal corneae. Corneal thickness data were derived from OCT images using semi-automated image processing techniques over the central 4 mm. RESULTS Changes in stromal and total corneal thickness followed a similar pattern throughout lens wear with oedema first detected 15 min after lens insertion (0.47 ± 0.09% increase in stromal and total corneal thickness, both p < 0.01) which peaked after 90 min of lens wear (1.36 ± 0.24% increase in stromal and 1.18 ± 0.20% increase in total corneal thickness, both p < 0.01) and gradually decreased thereafter. Epithelial thickness increased slightly during the first 30 min of lens wear (0.56 ± 0.30% increase, p > 0.05), then rapidly decreased reaching a minimum thickness 480 min after lens insertion (2.38 ± 0.70% decrease, p < 0.05). The maximum total corneal oedema, maximum stromal oedema, and maximum epithelial thinning were not associated with the initial central corneal clearance or the extent of lens settling over the 8 h period (all p > 0.05). Greater initial central corneal clearance resulted in less oxygen concentration reaching the cornea (∼2% less) based on previously published data, which manifested as ∼0.5% more central corneal oedema. CONCLUSIONS Scleral lens induced corneal oedema is stromal in nature. On average, central stromal and total corneal thickness increased rapidly following lens insertion and peaked after 90 min, while central epithelial thickness gradually decreased throughout lens wear consistent with natural diurnal variation. A greater initial central corneal clearance resulted in reduced oxygen delivery to the cornea, which had minimal short-term impact upon healthy eyes, however, minimising central corneal clearance may be important in eyes with reduced endothelial cell function to minimise hypoxic stress.
Collapse
Affiliation(s)
- Stephen J Vincent
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Australia.
| | - David Alonso-Caneiro
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Australia
| | - Michael J Collins
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Queensland University of Technology, Australia
| |
Collapse
|
18
|
Ozyol E, Özyol P. Comparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology. Indian J Ophthalmol 2017. [PMID: 28643709 PMCID: PMC5508455 DOI: 10.4103/ijo.ijo_618_16] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Purpose: The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. Materials and Methods: In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-domain OCT (SD-OCT) device with an anterior segment module (Spectralis), and noncontact pachymetry (NCP) device (Topcon TRK-2P). Agreement among the devices was analyzed using mean differences (i.e., bias) and Bland–Altman analysis with 95% limits of agreement (LoA). Results: Mean CCT measurements were 537.5 ± 47.5 μm for SS-OCT optical biometer, 532.3 ± 43.8 μm for Scheimpflug system, 521.3 ± 44.7 μm for SD-OCT device, and 518.0 ± 43.1 μm for NCP (P < 0.001). The SD-OCT device and NCP showed the closest agreement, with a bias of 2.6 μm (95% LoA, −3.6–8.8 μm), whereas the SS-OCT optical biometer and NCP showed the least agreement, with a bias of 18.7 μm (95% LoA, −2.1–39.5 μm). Bias was 16.1 μm (95% LoA, −3.1–35.3 μm) for SS-OCT optical biometer and SD-OCT, 5.1 μm (95% LoA, −6.8–17.0 μm) for SS-OCT optical biometer and Scheimpflug system, 10.9 μm (95% LoA, −15.1–36.9 μm) for SD-OCT device and Scheimpflug system, and 13.6 μm (95% LoA, −5–32.2 μm) for Scheimpflug system and NCP. Conclusions: SS-OCT optical biometer overestimates CCT measurements compared to Scheimpflug system, SD-OCT device, and NCP. Given mean differences and range variations in CCT measurements between devices, SS-OCT optical biometer and Scheimpflug system are interchangeable as are SD-OCT and NCP.
Collapse
Affiliation(s)
- Erhan Ozyol
- Department of Ophthalmology, Mugla Sitki Kocman University Training and Research Hospital, Muğla, Turkey
| | - Pelin Özyol
- Department of Ophthalmology, Faculty of Medicine, Mugla Sitki Kocman University, Muğla, Turkey
| |
Collapse
|