1
|
Kolbe O, Becker P, Degle S, Anders C. Trapezius activity during personal computer work with progressive addition lenses for general purpose and for computer work in neophytes. Ophthalmic Physiol Opt 2023; 43:1391-1405. [PMID: 37417310 DOI: 10.1111/opo.13196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 06/12/2023] [Accepted: 06/14/2023] [Indexed: 07/08/2023]
Abstract
INTRODUCTION This study analysed the impact of general purpose progressive addition lenses (GP-PALs) and computer progressive addition lenses (PC-PALs) on the activity of the trapezius muscle during computer operation. METHODS In this randomised, single-blinded, crossover study, surface electromyography (SEMG) signals were recorded bilaterally from the trapezius muscle during a 30-min computer task performed wearing different presbyopic corrections. The amplitude probability distribution function and its percentiles, gap frequency, muscular rest time and sustained low-level muscle activity periods were analysed in 32 subjects with artificially induced presbyopia. Subjectively perceived differences in vision and postural load between lenses were evaluated using a seven-item questionnaire (non-standardised, visual analogue scale ranged from 1 [bad] to 100 [good]). RESULTS Considering the SEMG data, no significant difference in the muscular activity of the trapezius muscle was observed when using GP-PALs or PC-PALs for computer operation. However, PC-PALs showed statistically and clinically significantly higher results for subjectively perceived visual quality (78.4-31.3; p < 0.001), spontaneous tolerance (79.2-31.3; p < 0.001) and field of view (75.9-23.5; p < 0.001) compared with GP-PALs. CONCLUSIONS Even though the electromyographic approach did not show a significant differentiation between the lenses, the subjective evaluation was clearly in favour of PC-PALs. Eye care practitioners should always take an occupational history of presbyopes, ask about the workplace situation and consider the use of PC-PALs.
Collapse
Affiliation(s)
- Oliver Kolbe
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Patrick Becker
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Stephan Degle
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Christoph Anders
- Division of Motor Research, Jena University Hospital, Jena, Germany
| |
Collapse
|
2
|
Kolbe O, Müller J, Degle S, Anders C. Analysis of real-world visual ergonomics at the visual display unit. Ophthalmic Physiol Opt 2023; 43:1169-1178. [PMID: 37278397 DOI: 10.1111/opo.13170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 05/10/2023] [Accepted: 05/12/2023] [Indexed: 06/07/2023]
Abstract
INTRODUCTION In this interventional study, the ergonomic workplace set-up and the impact of character size on subjectively estimated working productivity and computer vision syndrome (CVS) were evaluated in the field. METHODS The number of displays and their size, resolution, surface structure, position in the room and relation to the eye were evaluated for 152 units. CVS was assessed using the CVS-Questionnaire. Habitually used character size for an uppercase E was recorded and compared to the ISO 9241-303:2011, national standards (e.g., ANSI/HFES 100-2007) and national guidelines (e.g., German DGUV Information 215-410). In case of failure to comply with these standards, character size was increased to 22 angular minutes to reach the recommended ranges. Reasons for returning to former or smaller character sizes were recorded, and subjectively perceived changes in productivity were estimated by the participants using a visual analogue scale before and 2 weeks after the intervention using a questionnaire. RESULTS The average visual display unit consisted of two non-glare (matt) 24″ widescreen monitors that were located approximately 73 cm (primary) and 76 cm (secondary) from the eyes. The mean (SD) habitually set character size was 14.29 angular minutes (3.53) and therefore both statistically and clinically significantly too small compared with ISO 9241-303:2011 (p < 0.001). Increasing the character size to 22 angular minutes produced a 26% reduction in subjectively rated productivity (p < 0.001). No significant correlation between character size and symptoms of CVS was demonstrated. CONCLUSIONS In the workplaces investigated, recommendations for character size were not adhered to. This resulted in a reduction in productivity and was not compatible with some of the work requirements, for example, obtaining a broad overview of a spreadsheet.
Collapse
Affiliation(s)
- Oliver Kolbe
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Jennifer Müller
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Stephan Degle
- Department of Optometry and Vision Sciences, Faculty of SciTec, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Christoph Anders
- Division of Motor Research, Jena University Hospital, Jena, Germany
| |
Collapse
|
3
|
Oscar GE, Irene S, Raul M. Visual satisfaction with progressive addition lenses prescribed with novel foveal fixation axis measurements. Sci Rep 2023; 13:11262. [PMID: 37438410 DOI: 10.1038/s41598-023-38446-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2023] [Accepted: 07/08/2023] [Indexed: 07/14/2023] Open
Abstract
Progressive addition lens (PAL) prescription is usually conducted using the pupillary centre as a reference, which in general does not coincide with the visual axis (kappa distance), and this difference could induce undesired prismatic effects in far and near vision distances and adaptation problems. This study aimed to assess the impact on subjects' visual satisfaction with PALs prescribed based on foveal fixation axis (FFA) measurements. Two different PALs (LifeStyle 3i, Hoya Lens Iberia) were randomly prescribed [one with a customized inset (the difference between the FFA measurements (Ergofocus®, Lentitech, Spain) at far and near distances and the second with a standard inset (2.5 mm)] to be used by 71 healthy presbyopic volunteers in a prospective double-masked crossover clinical study involving one month of use of each PAL. Patients were self-classified into four groups according to their previous experience with PALs: neophyte, PAL users, PAL drop-out, and uncomfortable PAL users. Visual function and overall satisfaction with each PAL were collected and compared. Ninety-seven percent (95% CI 93-100%) of participants successfully adapted to PALs prescribed with FFA without significant differences (P = 0.26) among the study groups (100% neophyte and uncomfortable PAL users (95% CI 100% in both groups), 89% (95% CI 67-100%) PAL users and 94% (95% CI 82-100%) PAL drop-out group). There were no statistically significant differences in visual function (P > 0.05) between customized and standard inset PALs. Customized and standard inset lenses showed similar satisfaction (P > 0.42) that increased significantly (P < 0.01 without any carry-over effect) after 30 days of wear. PALs prescribed with FFA measurements showed high visual satisfaction, suggesting that these measurements are suitable for prescribing PAL adaptation processes. Additional research is necessary to assess differences in PAL users' performance with different prescription methods and lens designs.
Collapse
Affiliation(s)
- Garcia-Espinilla Oscar
- Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, 47011, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Paseo de Belén, 7 - Campus Miguel Delibes, 47011, Valladolid, Spain
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén, 17 - Campus Miguel Delibes, 47011, Valladolid, Spain
| | - Sanchez Irene
- Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, 47011, Valladolid, Spain.
- Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Paseo de Belén, 7 - Campus Miguel Delibes, 47011, Valladolid, Spain.
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén, 17 - Campus Miguel Delibes, 47011, Valladolid, Spain.
| | - Martin Raul
- Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, 47011, Valladolid, Spain
- Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Paseo de Belén, 7 - Campus Miguel Delibes, 47011, Valladolid, Spain
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Paseo de Belén, 17 - Campus Miguel Delibes, 47011, Valladolid, Spain
| |
Collapse
|
4
|
Galindo-Romero C, Rodríguez-Zamora CL, García-Ayuso D, Di Pierdomenico J, Valiente-Soriano FJ. Computer vision syndrome-related symptoms in presbyopic computer workers. Int Ophthalmol 2023:10.1007/s10792-023-02724-z. [PMID: 37103757 PMCID: PMC10133911 DOI: 10.1007/s10792-023-02724-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Accepted: 04/09/2023] [Indexed: 04/28/2023]
Abstract
PURPOSE To evaluate the prevalence of computer vision syndrome (CVS)-related symptoms in a presbyopic population using the computer as the main work tool, as well as the relationship of CVS with the electronic device use habits and the ergonomic factors. METHODS A sample of 198 presbyopic participants (aged 45-65 years) who regularly work with a computer completed a customised questionnaire divided into: general demographics, optical correction commonly used and for work, habits of electronic devices use, ergonomic conditions during the working hours and CVS-related symptoms during work performance. A total of 10 CVS-related symptoms were questioned indicating the severity with which they occurred (0-4) and the median total symptom score (MTSS) was calculated as the sum of the symptoms. RESULTS The MTSS in this presbyopic population is 7 ± 5 symptoms. The most common symptoms reported by participants are dry eyes, tired eyes and difficulties in refocusing. MTSS is higher in women (p < 0.05), in laptop computer users (p < 0.05) and in teleworkers compared to office workers (p < 0.05). Regarding ergonomic conditions, MTSS is higher in participants who do not take breaks while working (p < 0.05), who have an inadequately lighting in the workspace (p < 0.05) and in the participants reporting neck (p < 0.01) or back pain (p < 0.001). CONCLUSION There is a relationship between CVS-related symptoms, the use of electronic devices and the ergonomic factors, which indicates the importance of adapting workplaces, especially for home-based teleworkers, and following basic visual ergonomics rules.
Collapse
Affiliation(s)
- Caridad Galindo-Romero
- Departamento de Oftalmología, Facultad de Medicina, Universidad de Murcia and Instituto Murciano de Investigación Biosanitaria Pascual Parrilla (IMIB-Pascual Parrilla), Murcia, Spain.
- Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain.
- Grupo de Oftalmología Experimental, Instituto Murciano de Investigación Biosanitaria-Pascual Parrilla, Edificio LAIB Planta 5ª, Carretera Buenavista s/n, El Palmar, 30120, Murcia, Spain.
| | | | - Diego García-Ayuso
- Departamento de Oftalmología, Facultad de Medicina, Universidad de Murcia and Instituto Murciano de Investigación Biosanitaria Pascual Parrilla (IMIB-Pascual Parrilla), Murcia, Spain
- Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain
| | - Johnny Di Pierdomenico
- Departamento de Oftalmología, Facultad de Medicina, Universidad de Murcia and Instituto Murciano de Investigación Biosanitaria Pascual Parrilla (IMIB-Pascual Parrilla), Murcia, Spain
- Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain
| | - Francisco J Valiente-Soriano
- Departamento de Oftalmología, Facultad de Medicina, Universidad de Murcia and Instituto Murciano de Investigación Biosanitaria Pascual Parrilla (IMIB-Pascual Parrilla), Murcia, Spain.
- Facultad de Óptica y Optometría, Universidad de Murcia, Murcia, Spain.
- Grupo de Oftalmología Experimental, Instituto Murciano de Investigación Biosanitaria-Pascual Parrilla, Edificio LAIB Planta 5ª, Carretera Buenavista s/n, El Palmar, 30120, Murcia, Spain.
| |
Collapse
|
5
|
Wolffsohn JS, Davies LN, Sheppard AL. New insights in presbyopia: impact of correction strategies. BMJ Open Ophthalmol 2023. [DOI: 10.1136/bmjophth-2022-001122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
Presbyopia occurs when the physiologically normal age-related reduction in the eyes focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual’s requirements. Hence, it is more about the impact it has on an individual’s visual ability to function in their environment to maintain their lifestyle than a measured loss of focusing ability. Presbyopia has a significant impact on an individual’s quality of life and emotional state. While a range of amelioration strategies exist, they are often difficult to access in the developing world and prescribing is generally not optimal even in developed countries. This review identified the need for a standardised definition of presbyopia to be adopted. An appropriate battery of tests should be applied in evaluating presbyopic management options and the results of clinical trials should be published (even if unsuccessful) to accelerate the provision of better outcomes for presbyopes.
Collapse
|
6
|
Kolbe O, Bitterlich K, Lahne J, Degle S, Anders C. Surface Electromyography of the Trapezius and Sternocleidomastoid during Computer Work with Presbyopic Corrections. Optom Vis Sci 2022; 99:496-504. [PMID: 35412478 DOI: 10.1097/opx.0000000000001899] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
SIGNIFICANCE During computer work in controlled laboratory conditions, wearing multifocal contact lenses (MFCLs) showed no lower muscle load but increased subjective perception of comfort with equivalent visual quality and comparable tolerance. PURPOSE Because musculoskeletal complaints are frequent among computer workers, this study used the muscle electrophysiological activity of shoulder and neck muscles in presbyopic computer workers who received either progressive addition lenses for general purpose (GP-PALs) or MFCLs. METHODS For this crossover study, 11 presbyopic computer workers aged 55 ± 4 years (mean ± standard deviation) were equipped with GP-PALs and MFCLs in a randomized order. Surface electromyography signals were recorded bilaterally from shoulder and neck muscles during short-term computer work tasks using an optimally adjusted visual display unit workplace. The amplitude probability distribution function, the number and total duration of EMG gaps, and sustained low-level muscle activity periods of the surface electromyography signals were calculated. Comfort and correction type preferences were assessed. Head inclination was objectively evaluated. RESULTS Multifocal contact lenses elicited no significant lower muscle load than GP-PALs. The number of sustained low-level muscle activity periods longer than 60 seconds was similar between visual aids. The total amount of gaps was significantly higher with MFCLs (44 gaps) compared with progressive addition lenses for general purpose (15 gaps) in all analyzed periods for all participants. However, there were no significant differences for the median in the intraindividual comparisons (P = .22, dz = 0.52). Multifocal contact lenses scored statistically significant higher in comfort values with equivalent visual quality and comparable tolerance (P = .003, dz = 1.51). CONCLUSIONS Although the study failed to show clear results, wearing MFCLs seems to enhance working comfort compared with GP-PALs subjectively.
Collapse
Affiliation(s)
- Oliver Kolbe
- Faculty of SciTec, Department of Optometry and Vision Sciences, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Kathrin Bitterlich
- Faculty of SciTec, Department of Optometry and Vision Sciences, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Johanna Lahne
- Faculty of SciTec, Department of Optometry and Vision Sciences, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Stephan Degle
- Faculty of SciTec, Department of Optometry and Vision Sciences, Ernst-Abbe-University of Applied Sciences Jena, Jena, Germany
| | - Christoph Anders
- Division of Motor Research, Jena University Hospital, Jena, Germany
| |
Collapse
|
7
|
Sánchez-Brau M, Domenech-Amigot B, Brocal-Fernández F, Seguí-Crespo M. Computer vision syndrome in presbyopic digital device workers and progressive lens design. Ophthalmic Physiol Opt 2021; 41:922-931. [PMID: 33945635 DOI: 10.1111/opo.12832] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 03/16/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE To estimate the prevalence of computer vision syndrome (CVS) in presbyopic digital device workers using two ophthalmic progressive lens designs during the working day, and to analyse the association of CVS with sociodemographic, occupational, digital device exposure and refractive factors. METHODS This time series, quasi-experimental design study included 69 presbyopic digital device workers (age range: 46-69 years; mean ± SD = 54.7 ± 5.0). All used desktop computers at their workplace. Progressive addition lenses (PALs) and occupational lenses were used for three months each. CVS was measured with the CVS-Q© questionnaire before intervention (baseline) and at 1 week, 1 month and 3 months after wearing the lenses. A multivariate logistic regression model was used to identify the factors that were associated with an improved CVS-Q© score. RESULTS 37.7% of the subjects were female and 78.3% were ametropes; 65.2% had advanced presbyopia. 56.2% used digital devices at work >6 h day-1 . The prevalence of CVS at baseline, after wearing PALs for three months and after three months of occupational lens wear was 68.1%, 33.3% and 18.8%, respectively. The mean CVS-Q© score was lower with occupational lenses than with PALs (p = 0.001). 40.6% of the digital device workers improved their CVS-Q© score ≥2 points with the occupational lenses. Ametropes were less likely than emmetropes to improve with occupational lenses (OR = 0.27, p = 0.05). 89.8% of the sample workers were satisfied or very satisfied with the occupational lenses and 71% were similarly satisfied with the PALs. 73.9% chose the occupational lenses as their first choice of lens for digital device use, compared with 17.4% for PALs. CONCLUSIONS Computer vision syndrome is reduced in presbyopic desktop computer workers wearing occupational lenses compared with PALs, especially in emmetropes.
Collapse
Affiliation(s)
- Mar Sánchez-Brau
- Doctoral Programme in Health Sciences, University of Alicante, Alicante, Spain
| | | | - Francisco Brocal-Fernández
- Department of Physics, Systems Engineering and Signal Theory, University of Alicante, Alicante, Spain.,University Institute of Physics Applied to Sciences and Technologies, University of Alicante, Alicante, Spain
| | - Mar Seguí-Crespo
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.,Public Health Research Group, University of Alicante, Alicante, Spain
| |
Collapse
|
8
|
Abstract
CLINICAL RELEVANCE Home-isolation and social distancing during the COVID-19 pandemic caused increased use of digital devices, posing a greater risk of developing digital eye strain-related symptoms. Eye-care professionals should educate patients about limiting screen time and managing digital eye strain symptoms. BACKGROUND This study aimed to evaluate the COVID-19 isolation's impact on digital device use by comparing hours spent on digital devices before and during the 24-hour curfew in Saudi Arabia, while assessing the symptoms associated with digital eye strain. METHODS A self-reported questionnaire was used to compare the total hours per day, either continuous or intermittent, spent on digital devices during and before curfew, and the association of these durations with digital eye strain. RESULTS A total of 1,939 participants, (mean ± SD: 33 ± 12.2 years and 72% women) were recruited. Results showed a significant difference between usage duration before and during curfew. Digital eye strain incidence was 78% during the curfew. Chi-squared analysis indicated most symptoms are associated with usage duration and employment status. Multivariate analysis revealed significant associations between digital eye strain and the following factors: using more than one device (odds ratio 1.208, 95% confidence interval: 1.068-1.3661), age, optical correction, employment status, gender, using rewetting drops, and usage duration. CONCLUSIONS In this population, prolonged use of digital devices significantly increased during home-isolation. Digital eye strain incidence increased during curfew. Regular eye exams should be encouraged to ensure the use of optimum prescription use and meet the specific visual demands required for the use of digital devices. Eye-health strategies and awareness campaigns should be employed on the importance of regular eye exams, decreasing screen time, practising the 20-20-20 rule, and the use of rewetting drops to help reduce the symptoms of digital eye strain during this period.
Collapse
|
9
|
Garcia Garcia M, Rifai K, Wahl S, Watson T. Adaptation to geometrically skewed moving images: An asymmetrical effect on the double-drift illusion. Vision Res 2020; 179:75-84. [PMID: 33310640 DOI: 10.1016/j.visres.2020.11.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 10/28/2020] [Accepted: 11/07/2020] [Indexed: 11/29/2022]
Abstract
Progressive addition lenses introduce distortions in the peripheral visual field that alter both form and motion perception. Here we seek to understand how our peripheral visual field adapts to complex distortions. The adaptation was induced across the visual field by geometrically skewed image sequences, and aftereffects were measured via changes in perception of the double-drift illusion. The double-drift or curveball stimulus contains both local and object motion. Therefore, the aftereffects induced by geometrical distortions might be indicative of how this adaptation interacts with the local and object motion signals. In the absence of the local motion components, the adaptation to skewness modified the perceived trajectory of object motion in the opposite direction of the adaptation stimulus skew. This effect demonstrates that the environment can also tune perceived object trajectories. Testing with the full double-drift stimulus, adaptation to a skew in the opposite direction to the local motion component induced a change in perception, reducing the illusion magnitude (when the stimulus was presented on the right side of the screen. A non-statistically significant shift, when stimuli were on the left side). However, adaptation to the other orientation resulted in no change in the strength of the double-drift illusion (for both stimuli locations). Thus, it seems that the adaptor's orientation and the motion statistics of the stimulus jointly define the perception of the measured aftereffect. In conclusion, not only size, contrast or drifting speed affects the double-drift illusion, but also adaptation to image distortions.
Collapse
Affiliation(s)
- Miguel Garcia Garcia
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Tuebingen 72076, Germany; School of Psychology, Western Sydney University, New South Wales 2214, Australia.
| | - Katharina Rifai
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Tuebingen 72076, Germany
| | - Siegfried Wahl
- Carl Zeiss Vision International GmbH, Turnstrasse 27, 73430 Aalen, Germany; Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Tuebingen 72076, Germany
| | - Tamara Watson
- School of Psychology, Western Sydney University, New South Wales 2214, Australia
| |
Collapse
|
10
|
Prevalence of Computer Vision Syndrome and Its Relationship with Ergonomic and Individual Factors in Presbyopic VDT Workers Using Progressive Addition Lenses. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17031003. [PMID: 32033372 PMCID: PMC7038098 DOI: 10.3390/ijerph17031003] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 02/01/2020] [Accepted: 02/02/2020] [Indexed: 11/25/2022]
Abstract
This cross-sectional study estimated computer vision syndrome (CVS) prevalence and analysed its relationship with video display terminal (VDT) exposure, as well as sociodemographic, refractive, environmental, and ergonomic characteristics in 109 presbyopic VDT workers wearing progressive addition lenses (PALs). Usual spectacles were measured with a lens analyser, and subjective refraction was performed by an optometrist. CVS was measured with the CVS-Q©. VDT exposure was collected. Ergonomic evaluations were conducted in a normal working posture looking at the screen. Air temperature and relative humidity were measured (thermohygrometer), and illumination was measured (luxmeter). Descriptive analysis and differences in CVS prevalence, as a function of the explanatory variables, were performed (chi-square test). Multivariate logistic regression was used to identify factors associated with CVS (OR and 95% CI). The mean age was 54.0 ± 4.8 years, and 43.1% were women. The mean hours of VDT use at work was 6.5 ± 1.3 hours/day. The prevalence of CVS was 74.3%. CVS was significantly associated with women (OR 3.40; 95% CI, 1.12–10.33), non-neutral neck posture (OR 3.27; 95% CI, 1.03–10.41) and altered workplace lighting (OR 3.64; 95% CI, 1.22–10.81). Providing training and information to workers regarding the importance of adequate lighting and ergonomic postures during VDT use is advised to decrease CVS and increase workplace quality of life.
Collapse
|