1
|
Philibert M, Milea D. Basics, benefits, and pitfalls of pupillometers assessing visual function. Eye (Lond) 2024; 38:2415-2421. [PMID: 38802485 PMCID: PMC11306737 DOI: 10.1038/s41433-024-03151-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Revised: 04/22/2024] [Accepted: 05/17/2024] [Indexed: 05/29/2024] Open
Abstract
Numerous commercially and non-commercially available pupillometers are nowadays able to assess various biological functions in humans, by evaluating pupils' dynamics in response to specific stimuli. However, the use of pupillometers for ophthalmic afferent evaluations (i.e., photoreceptoral responses) in real-world settings is relatively limited. Recent scientific and technological advances, coupled with artificial intelligence methods have improved the performance of such devices to objectively detect, quantify, and classify functional disturbances of the retina and the optic nerve. This review aims to summarize the scientific principles, indications, outcomes, and current limitations of pupillometry used for evaluation of afferent pathways in ophthalmic clinical settings.
Collapse
Affiliation(s)
| | - Dan Milea
- Rothschild Foundation Hospital, Paris, France.
- Copenhagen University Hospital, Copenhagen, Denmark.
- Singapore National Eye Centre, Singapore, Singapore.
- Angers University Hospital, Angers, France.
- Duke-NUS Medical School, Singapore, Singapore.
- Singapore Eye Research Institute, Singapore, Singapore.
| |
Collapse
|
2
|
Sabeti F, van Kleef JP, Iyer RM, Carle CF, Nolan CJ, Chia RH, Maddess T. Discriminating early-stage diabetic retinopathy with subjective and objective perimetry. Front Endocrinol (Lausanne) 2024; 14:1333826. [PMID: 38264290 PMCID: PMC10804944 DOI: 10.3389/fendo.2023.1333826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 12/13/2023] [Indexed: 01/25/2024] Open
Abstract
Introduction To prevent progression of early-stage diabetic retinopathy, we need functional tests that can distinguish multiple levels of neural damage before classical vasculopathy. To that end, we compared multifocal pupillographic objective perimetry (mfPOP), and two types of subjective automated perimetry (SAP), in persons with type 2 diabetes (PwT2D) with either no retinopathy (noDR) or mild to-moderate non-proliferative retinopathy (mmDR). Methods Both eyes were assessed by two mfPOP test methods that present stimuli within either the central ±15° (OFA15) or ±30° (OFA30), each producing per-region sensitivities and response delays. The SAP tests were 24-2 Short Wavelength Automated Perimetry and 24-2 Matrix perimetry. Results Five of eight mfPOP global indices were significantly different between noDR and mmDR eyes, but none of the equivalent measures differed for SAP. Per-region mfPOP identified significant hypersensitivity and longer delays in the peripheral visual field, verifying earlier findings. Diagnostic power for discrimination of noDR vs. mmDR, and normal controls vs. PwT2D, was much higher for mfPOP than SAP. The mfPOP per-region delays provided the best discrimination. The presence of localized rather than global changes in delay ruled out iris neuropathy as a major factor. Discussion mfPOP response delays may provide new surrogate endpoints for studies of interventions for early-stage diabetic eye damage.
Collapse
Affiliation(s)
- Faran Sabeti
- Eccles Institute for Neuroscience, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT, Australia
- Discipline of Optometry, Faculty of Health, University of Canberra, Canberra, ACT, Australia
| | - Joshua P. van Kleef
- Eccles Institute for Neuroscience, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT, Australia
| | - Rakesh M. Iyer
- Department of Endocrinology, The Canberra Hospital, Garran, ACT, Australia
| | - Corinne F. Carle
- Eccles Institute for Neuroscience, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT, Australia
| | - Christopher J. Nolan
- Department of Endocrinology, The Canberra Hospital, Garran, ACT, Australia
- School of Medicine and Psychology, The Australian National University, Canberra, ACT, Australia
| | - Rong Hui Chia
- School of Medicine, University of Western Australia, Crawley, WA, Australia
| | - Ted Maddess
- Eccles Institute for Neuroscience, The John Curtin School of Medical Research, The Australian National University, Canberra, ACT, Australia
| |
Collapse
|
3
|
Decleva D, Vidal KS, Kreuz AC, de Menezes PAHL, Ventura DF. Alterations of color vision and pupillary light responses in age-related macular degeneration. Front Aging Neurosci 2023; 14:933453. [PMID: 36688155 PMCID: PMC9849391 DOI: 10.3389/fnagi.2022.933453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Accepted: 11/24/2022] [Indexed: 01/06/2023] Open
Abstract
Introduction Age-related macular degeneration (AMD) is the leading cause of irreversible central vision loss in developed countries and one of the leading causes of blindness. In this work, we evaluated color vision and the pupil light reflex (PLR) to assess visual function in patients with early and neovascular AMD (NVAMD) compared with the control group. Methods We recruited 34 early patients with dry AMD and classified them into two groups following AREDS: 13 patients with NVAMD and 24 healthy controls. Controls and patients with early dry AMD had visual acuity (VA) best or equal to 20/25 (0.098 logMAR). Color vision was assessed in controls and patients with early dry AMD using the Cambridge Color Test (CCT) 2.0 through the Trivector protocol. The PLR was evaluated using a Ganzfeld, controlled by the RETI-port system. The stimuli consisted of 1s blue (470 nm) and red (631 nm) light flashes presented alternately at 2-min intervals. To assess the cone contribution, we used a red flash at 2.4 log cd.m-2, with a blue background at 0.78 log cd.m-2. For rods, we used 470-nm flashes at -3 log cd.m-2, and for the melanopsin function of ipRGCs, we used 470 nm at 2.4 log cd.m-2. Results Patients with early dry AMD had reduced color discrimination in all three axes: protan (p = 0.0087), deutan (p = 0.0180), and tritan (p = 0.0095) when compared with the control group. The PLR has also been affected in patients with early dry AMD and patients with NVAMD. The amplitude for the melanopsin-driven response was smaller in patients with early dry AMD (p = 0.0485) and NVAMD (p = 0.0035) than in the control group. The melanopsin function was lower in patients with NVAMD (p = 0.0290) than the control group. For the rod-driven response, the latency was lower in the NVAMD group (p = 0.0041) than in the control group. No changes were found in cone-driven responses between the control and AMD groups. Conclusion Patients with early dry AMD present diffusely acquired color vision alteration detected by CCT. Rods and melanopsin contributions for PLR are affected in NVAMD. The CCT and the PLR may be considered sensitive tests to evaluate and monitor functional changes in patients with AMD.
Collapse
Affiliation(s)
- Diego Decleva
- Department of Experimental Psychology, Institute of Psychology, University of São Paulo, São Paulo, Brazil,Neuroscience and Behavior Graduate Studies Program, Institute of Psychology, University of São Paulo, São Paulo, Brazil,*Correspondence: Diego Decleva,
| | - Kallene Summer Vidal
- Department of Experimental Psychology, Institute of Psychology, University of São Paulo, São Paulo, Brazil,Prevent Senior Health Operator, São Paulo, Brazil,Service of Interdisciplinary Neuromodulation, Laboratory of Neurosciences (LIM-27), Institute of Psychiatry, Medical School, University of São Paulo, São Paulo, Brazil,Young Medical Leadership Program of National Academy of Medicine in Brazil, Rio de Janeiro, Brazil
| | - Andre Carvalho Kreuz
- Neuroscience and Behavior Graduate Studies Program, Institute of Psychology, University of São Paulo, São Paulo, Brazil
| | | | - Dora Fix Ventura
- Department of Experimental Psychology, Institute of Psychology, University of São Paulo, São Paulo, Brazil,Neuroscience and Behavior Graduate Studies Program, Institute of Psychology, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
4
|
Rapid Objective Testing of Visual Function Matched to the ETDRS Grid and Its Diagnostic Power in Age-Related Macular Degeneration. OPHTHALMOLOGY SCIENCE 2022; 2:100143. [PMID: 36249701 PMCID: PMC9559873 DOI: 10.1016/j.xops.2022.100143] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 01/17/2022] [Accepted: 03/14/2022] [Indexed: 11/21/2022]
Abstract
Purpose To study the power of an 80-second multifocal pupillographic objective perimetry (mfPOP) test tailored to the ETDRS grid to diagnose age-related macular degeneration (AMD) by Age-Related Eye Disease Study (AREDS) severity grade. Design Evaluation of a diagnostic technology. Methods We compared diagnostic power of acuity, ETDRS grid retinal thickness data, new 80-second M18 mfPOP test, and two wider-field 6-minute mfPOP tests (Macular-P131, Widefield-P129). The M18 stimuli match the size and shape of bifurcated ETDRS grid regions, allowing easy structure–function comparisons. M18, P129, and P131 stimuli test both eyes concurrently. We recruited 34 patients with early-stage AMD with a mean ± standard deviation (SD) age of 72.6 ± 7.06 years. The M18 and P129 plus P131 stimuli had 26 and 51 control participants, respectively with mean ± SD ages of 73.1 ± 8.17 years and 72.1 ± 5.83 years, respectively. Multifocal pupillographic objective perimetry testing used the Food and Drug Administration-cleared Objective FIELD Analyzer (OFA; Konan Medical USA). Main Outcome Measures Percentage area under the receiver operator characteristic curve (AUC) and Hedge’s g effect size. Results Acuity and OCT ETDRS grid thickness and volume produced reasonable diagnostic power (percentage AUC) for AREDS grade 4 eyes at 83.9 ± 9.98% and 90.2 ± 6.32% (mean ± standard error), respectively, but not for eyes with less severe disease. By contrast, M18 stimuli produced percentage AUCs from 72.8 ± 6.65% (AREDS grade 2) to 92.9 ± 3.93% (AREDS grade 4), and 82.9 ± 3.71% for all eyes. Hedge’s g effect sizes ranged from 0.84 to 2.32 (large to huge). Percentage AUC for P131 stimuli performed similarly and for P129 performed somewhat less well. Conclusions The rapid and objective M18 test provided diagnostic power comparable with that of wider-field 6-minute mfPOP tests. Unlike acuity or OCT ETDRS grid data, OFA tests produced reasonable diagnostic power in AREDS grade 1 to 3 eyes.
Collapse
|
5
|
Multifocal pupillographic objective perimetry for assessment of early diabetic retinopathy and generalised diabetes-related tissue injury in persons with type 1 diabetes. BMC Ophthalmol 2022; 22:166. [PMID: 35418088 PMCID: PMC9008936 DOI: 10.1186/s12886-022-02382-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Accepted: 03/28/2022] [Indexed: 12/01/2022] Open
Abstract
Background To examine the potential utility of five multifocal pupillographic objective perimetry (mfPOP) protocols, in the assessment of early diabetic retinopathy (DR) and generalised diabetes-related tissue injury in subjects with type 1 diabetes (T1D). Methods Twenty-five T1D subjects (age 41.8 ± 12.1 (SD) years, 13 male) with either no DR (n = 13) or non-proliferative DR (n = 12), and 23 age and gender-matched control subjects (age 39.7 ± 12.9 years, 9 male) were examined by mfPOP using five different stimulus methods differing in visual field eccentricity (central 30° and 60°), and colour (blue, yellow or green test-stimuli presented on, respectively, a blue, yellow or red background), each assessing 44 test-locations per eye. In the T1D subjects, we assessed 16 metabolic status and diabetes complications variables. These were summarised as three principal component analysis (PCA) factors. DR severity was assessed using Early Treatment of Diabetic Retinopathy Study (ETDRS) scores. Area under the curve (AUC) from receiver operator characteristic analyses quantified the diagnostic power of mfPOP response sensitivity and delay deviations for differentiating: (i) T1D subjects from control subjects, (ii) T1D subjects according to three levels of the identified PCA-factors from control subjects, and (iii) TID subjects with from those without non-proliferative DR. Results The two largest PCA-factors describing the T1D subjects were associated with metabolic variables (e.g. body mass index, HbA1c), and tissue-injury variables (e.g. serum creatinine, vibration perception). Linear models showed that mfPOP per-region response delays were more strongly associated than sensitivities with the metabolic PCA-factor and ETDRS scores. Combined mfPOP amplitude and delay measures produced AUCs of 90.4 ± 8.9% (mean ± SE) for discriminating T1D subjects with DR from control subjects, and T1D subjects with DR from those without of 85.9 ± 8.8%. The yellow and green stimuli performed better than blue on most measures. Conclusions/interpretation In T1D subjects, mfPOP testing was able to identify localised visual field functional abnormalities (retinal/neural reflex) in the absence or presence of mild DR. mfPOP responses were also associated with T1D metabolic status, but less so with early stages of non-ophthalmic diabetes complications.
Collapse
|
6
|
Carle CF, James AC, Sabeti F, Kolic M, Essex RW, Shean C, Jeans R, Saikal A, Licinio A, Maddess T. Clustered Volleys Stimulus Presentation for Multifocal Objective Perimetry. Transl Vis Sci Technol 2022; 11:5. [PMID: 35113130 PMCID: PMC8819283 DOI: 10.1167/tvst.11.2.5] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose Multifocal pupillographic objective perimetry (mfPOP) is being developed as an alternative to subjective threshold perimetry for the management of visual and neurological disorders. Here, we evaluate, in normal subjects, differences in signal quality between the original mfPOP method of spatially sparse Continuous stimulus presentation and the new Clustered Volleys (CVs) method. We hypothesized that the CVs method would lead to increased signal-to-noise ratios (SNRs) over the original method due to the stabilization of gain within the pupillary system. Methods Data were collected from six separate studies where otherwise-identical pairs of mfPOP tests using either the original Continuous stimulus presentation method or the new CVs method were undertaken; 440 6-minute tests from 96 normal subjects of varying ages were included. Per-region SNRs were compared between the two methods. Results Mean SNRs for the CVs mfPOP variants were between 35% and 57% larger than the original Continuous mfPOP variants (P < 0.001 in five of six studies). Similarly, the goodness-of-fit measure (r2) demonstrated large and significant fold increases of between 2.3× and 3.4× over the original method (all P < 0.001). Significant improvements in SNRs were present in all of the 88 test regions (44/eye), ranging between 8.4% and 93.7%; mean SNRs were significantly larger in 98% of test subjects. Conclusions The CVs mfPOP stimulus presentation method produced substantial increases in signal quality over the original method. This is likely due to the stabilization of pupillary gain during stimulus presentation. Translational Relevance These improvements increase diagnostic accuracy and have enabled shorter, 80-second mfPOP tests to be developed.
Collapse
Affiliation(s)
- Corinne F Carle
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Andrew C James
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Faran Sabeti
- John Curtin School of Medical Research, Australian National University, Canberra, Australia.,Optometry and Vision Science, University of Canberra, Canberra, Australia
| | - Maria Kolic
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Rohan W Essex
- John Curtin School of Medical Research, Australian National University, Canberra, Australia.,Canberra Hospital, Canberra, Australia
| | - Chris Shean
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Rhiannon Jeans
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Aiasha Saikal
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Alice Licinio
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Ted Maddess
- John Curtin School of Medical Research, Australian National University, Canberra, Australia
| |
Collapse
|
7
|
Rai BB, Essex RW, Sabeti F, Maddess T, Rohan EMF, van Kleef JP, Carle CF. An Objective Perimetry Study of Central Versus Peripheral Sensitivities and Delays in Age-Related Macular Degeneration. Transl Vis Sci Technol 2021; 10:24. [PMID: 34932115 PMCID: PMC8711003 DOI: 10.1167/tvst.10.14.24] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 11/18/2021] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to compare central versus peripheral retinal sensitivities and delays in neovascular age-related macular degeneration (nAMD) using US Food and Drug Administration (FDA)-cleared multifocal pupillographic objective perimetry (mfPOP). Methods We recruited 18 patients with nAMD and commenced Pro re nata intravitreal anti- vascular endothelial growth factor (VEGF) injection. We compared macular (±15 degrees) and wide-field (±30 degrees) mfPOP variants. We examined temporal correlations between treated and untreated fellow eyes. We fitted linear models to selected treatment patterns, and compared the ability of central versus peripheral responses to predict the need for treatment. Results Central sensitivity decreased by -2.23 ± 0.051 dB/month (P < 0.0002) in treated eyes, and -0.17 ± 0.07 dB/month (P = 0.033) in untreated eyes. Treated eyes showed quicker central responses by 13.08 ± 3.77 ms than untreated eyes (P = 0.001). Based on peripheral responses, we identified two eye-types. Among positive-eyes peripheral sensitivity increased by 9.88 ± 4.41 dB (P = 0.042) before treatment; delays increased by 3.49 ± 1.75 ms/month (P = 0.049). For negative-eyes peripheral delays were shorter a month before treatment by 9.38 ± 3.59 ms (P = 0.013). Correlations between treatment and peripheral sensitivities or delays peaked at 1 to 2 months post-treatment. Peripheral data significantly determined treatment frequency and final acuity (all P < 0.044). Conclusions Peripheral macular function of treated and untreated eyes divided eyes into positive and negative groups. Those peripheral responses determined outcomes; changes preceding active disease by 1 to 3 months. Overall, mfPOP may provide potential biomarkers to assist nAMD management. Translational Relevance Objective perimetry may identify the requirement for treatment in nAMD that accords with the decision of a skilled clinician based on optical coherence tomography (OCT) and clinical findings.
Collapse
Affiliation(s)
- Bhim B Rai
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
| | - Rohan W Essex
- Academic Unit, ANU Medical School, ANU, Canberra, Australia Capital Territory, Australia
- Department of Ophthalmology, The Canberra Hospital, ACT Health, Canberra, ACT, Australia
| | - Faran Sabeti
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
- School of Optometry, University of Canberra, Bruce, Canberra, Australia Capital Territory, Australia
| | - Ted Maddess
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
| | - Emilie M F Rohan
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
| | - Joshua P van Kleef
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
| | - Corinne F Carle
- John Curtin School of Medical Research, Australian National University, Australia Capital Territory, Australia
| |
Collapse
|
8
|
Sabeti F, James AC, Carle CF, Essex RW, Bell A, Maddess T. Comparing multifocal pupillographic objective perimetry (mfPOP) and multifocal visual evoked potentials (mfVEP) in retinal diseases. Sci Rep 2017; 7:45847. [PMID: 28368051 PMCID: PMC5377468 DOI: 10.1038/srep45847] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2016] [Accepted: 03/03/2017] [Indexed: 11/09/2022] Open
Abstract
Multifocal pupillographic objective perimetry (mfPOP) shows regions of slight hypersensitivity away from retinal regions damaged by diabetes or age-related macular degeneration (AMD). This study examines if such results also appear in multifocal visual evoked potentials (mfVEPs) recorded on the same day in the same patients. The pupil control system receives input from the extra-striate cortex, so we also examined evidence for such input. We recruited subjects with early type 2 diabetes (T2D) with no retinopathy, and patients with unilateral exudative AMD. Population average responses of the diabetes patients, and the normal fellow eyes of AMD patients, showed multiple regions of significant hypersensitivity (p < 0.05) on both mfPOP and mfVEPs. For mfVEPs the occipital electrodes showed fewer hypersensitive regions than the surrounding electrodes. More advanced AMD showed regions of suppression becoming centrally concentrated in the exudative AMD areas. Thus, mfVEP electrodes biased towards extra-striate cortical responses (surround electrodes) appeared to show similar hypersensitive visual field locations to mfPOP in early stage diabetic and AMD damage. Our findings suggest that hypersensitive regions may be a potential biomarker for future development of AMD or non-proliferative diabetic retinopathy, and may be more informative than visual acuity which remains largely undisturbed during early disease.
Collapse
Affiliation(s)
- Faran Sabeti
- Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Canberra, Australia.,Department of Ophthalmology, The Canberra Hospital, Canberra, Australia
| | - Andrew C James
- Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Corinne F Carle
- Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Rohan W Essex
- Department of Ophthalmology, The Canberra Hospital, Canberra, Australia.,Medical School, Australian National University, Canberra, Australia
| | - Andrew Bell
- Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Canberra, Australia
| | - Ted Maddess
- Eccles Institute of Neuroscience, John Curtin School of Medical Research, Australian National University, Canberra, Australia
| |
Collapse
|
9
|
Chibel R, Sher I, Ben Ner D, Mhajna MO, Achiron A, Hajyahia S, Skaat A, Berchenko Y, Oberman B, Kalter-Leibovici O, Freedman L, Rotenstreich Y. Chromatic Multifocal Pupillometer for Objective Perimetry and Diagnosis of Patients with Retinitis Pigmentosa. Ophthalmology 2016; 123:1898-911. [PMID: 27432203 DOI: 10.1016/j.ophtha.2016.05.038] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2016] [Revised: 05/21/2016] [Accepted: 05/23/2016] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To assess visual field (VF) defects and retinal function objectively in healthy participants and patients with retinitis pigmentosa (RP) using a chromatic multifocal pupillometer. DESIGN Cross-sectional study. PARTICIPANTS The right eyes of 16 healthy participants and 13 RP patients. METHODS Pupil responses to red and blue light (peak, 485 and 625 nm, respectively) presented by 76 light-emitting diodes, 1.8-mm spot size at different locations of a 16.2° VF were recorded. Subjective VFs of RP patients were determined using chromatic dark-adapted Goldmann VFs (CDA-GVFs). Six healthy participants underwent 2 pupillometer examinations to determine test-retest reliability. MAIN OUTCOME MEASURES Three parameters of pupil contraction were determined automatically: percentage of change of pupil size (PPC), maximum contraction velocity (MCV; in pixels per second), and latency of MCV (LMCV; in seconds). The fraction of functional VF was determined by CDA-GVF. RESULTS In healthy participants, higher PPC and MCV were measured in response to blue compared with red light. The LMCV in response to blue light was relatively constant throughout the VF. Healthy participants demonstrated higher PPC and MCV and shorter LMCV in central compared with peripheral test points in response to red light. Test-retest correlation coefficients were 0.7 for PPC and 0.5 for MCV. In RP patients, test point in which the PPC and MCV were lower than 4 standard errors from the mean of healthy participants correlated with areas that were indicated as nonseeing by CDA-GVF. The mean absolute deviation in LMCV parameter in response to the red light between different test point was significantly higher in RP patients (range, 0.16-0.47) than in healthy participants (range, 0.02-0.16; P < 0.0001) and indicated its usefulness as a diagnostic tool with high sensitivity and specificity (area under the receiver operating characteristic curve (AUC), 0.97, Mann-Whitney-Wilcoxon analysis). Randomly reducing the number of test points to a total of 15 points did not significantly reduce the AUC in RP diagnosis based on this parameter. CONCLUSIONS This study demonstrates the feasibility of using a chromatic multifocal pupillometer for objective diagnosis of RP and assessment of VF defects.
Collapse
Affiliation(s)
- Ron Chibel
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Ifat Sher
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Daniel Ben Ner
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Mohamad O Mhajna
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel
| | - Asaf Achiron
- Department of Ophthalmology, Wolfson Medical Center, Holon, Israel
| | - Soad Hajyahia
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel
| | - Alon Skaat
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yakir Berchenko
- Biostatistics Unit, Gertner Institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Bernice Oberman
- Biostatistics Unit, Gertner Institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Ofra Kalter-Leibovici
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Unit of Cardiovascular Epidemiology, Gertner Institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Laurence Freedman
- Biostatistics Unit, Gertner Institute for Epidemiology and Health Policy Research, Ramat Gan, Israel
| | - Ygal Rotenstreich
- The Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
10
|
Sabeti F, Maddess T, Essex RW, Saikal A, James AC, Carle CF. Multifocal pupillography in early age-related macular degeneration. Optom Vis Sci 2014; 91:904-15. [PMID: 24987814 DOI: 10.1097/opx.0000000000000319] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the potential of multifocal pupillographic objective perimetry to assess changes in retinal function with clinical severity of age-related macular degeneration (AMD). METHODS Pupil responses were recorded from 40 subjects with AMD and 23 normal control subjects (mean ± SD age, 71.3 ± 5.1 years). Age-related macular degeneration subjects were classified according to the Age-Related Eye Disease Study (AREDS) classification system and allocated into one of four AMD severity groups. Three multifocal pupillographic objective perimetry stimulus variants that were identical in luminance but varied in spatiotemporal sequence were used. In one of the three protocols, stimuli were presented with a pedestal flicker for 266 milliseconds at 15 Hz. RESULTS On average, response amplitudes demonstrated a significant change in sensitivity with progression from early-stage (0.32 ± 0.08 dB, t = 3.88) to late-stage (-1.60 ± 0.12 dB, t = -12.7) age-related macular degeneration. Response delays followed a similar trend with the longest delays in AREDS4 (57.2 ± 1.9 milliseconds, t = 29.5). Ring analysis identified the largest mean effect on responses within the central 6 degrees of fixation. The NewStimuli protocol achieved the best diagnostic accuracy across all severity groups with area under the curve values of 0.85 ± 0.066 (AREDS1), 0.908 ± 0.085 (AREDS2), 0.929 ± 0.040 (AREDS3), and 1.0 ± 0.0 (AREDS4). CONCLUSIONS The mean effect of AMD on contraction amplitudes and response delays reflected the severity of disease, and the NewStimuli protocol achieved good diagnostic accuracy across all AMD severity groups. Multifocal pupillographic objective perimetry may potentially be a useful method in monitoring progression of AMD and assessing change in retinal function with novel interventions in early AMD. Longitudinal studies are required to identify biomarkers that predict eyes at risk of progression.
Collapse
Affiliation(s)
- Faran Sabeti
- *PhD †MBBS ‡BSc ARC Centre of Excellence in Vision Science and Centre for Visual Sciences, The John Curtin School of Medical Research, The Australian National University, Canberra, Australian Capital Territory, Australia (all authors); and Ophthalmology Department, The Australian National University, Canberra Hospital, Australian Capital Territory, Australia (RWE)
| | | | | | | | | | | |
Collapse
|
11
|
Carle CF, James AC, Kolic M, Essex RW, Maddess T. Luminance and colour variant pupil perimetry in glaucoma. Clin Exp Ophthalmol 2014; 42:815-24. [PMID: 24725214 DOI: 10.1111/ceo.12346] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2013] [Accepted: 04/06/2014] [Indexed: 11/28/2022]
Abstract
BACKGROUND This study investigated the diagnostic utility for glaucoma of multifocal pupillographic objective perimetry stimuli targeting different components of the pupillary response: cortically derived colour responses and subcortical luminance responses. DESIGN Observational cross-sectional study undertaken at the Australian National University. PARTICIPANTS Thirty-five eyes of 24 glaucoma subjects and 46 eyes of 23 normal subjects. METHODS Subjects were tested with three multifocal pupillographic objective perimetry stimulus variants. The luminance-only variant (YYbal) utilized yellow stimuli on a yellow background; mixed colour and luminance protocols utilized green stimuli on a red background (RGbal, RG). Stimuli of 33 ms duration were presented at mean intervals of 4 s/region. MAIN OUTCOME MEASURES Pupil constriction amplitude and time to peak. Area under the receiver operating characteristic curve was the main measure of sensitivity and specificity for glaucoma. RESULTS Colour and luminance protocols were more accurate at differentiating glaucoma subjects from normal subjects than the luminance-only protocol, and produced the largest reductions in amplitudes. This type of protocol also produced the highest overall sensitivity and specificity for glaucoma (receiver operating characteristic % area under the curve: severe, 100%; moderate, 94.4%; mild, 71.0%). Pattern deviations tended to produce higher area under the receiver operating characteristic curves in eyes classified as mild. Significant differences in the means of the six worst amplitude deviations were observed between normal and severe glaucoma subjects only. CONCLUSIONS Stimuli targeting both cortical pupillary colour response and subcortical pupillary luminance response components produced higher diagnostic accuracy than stimuli targeting subcortical pupillary luminance responses alone. Inclusion of constriction latencies further improved accuracy.
Collapse
Affiliation(s)
- Corinne F Carle
- ARC Centre of Excellence in Vision Science, The John Curtin School of Medical Research, The Australian National University, Canberra, Australian Capital Territory, Australia
| | | | | | | | | |
Collapse
|
12
|
Development and validation of an associative model for the detection of glaucoma using pupillography. Am J Ophthalmol 2013; 156:1285-1296.e2. [PMID: 24011523 DOI: 10.1016/j.ajo.2013.07.026] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2013] [Revised: 07/26/2013] [Accepted: 07/29/2013] [Indexed: 11/22/2022]
Abstract
PURPOSE To develop and validate an associative model using pupillography that best discriminates those with and without glaucoma. DESIGN A prospective case-control study. METHODS We enrolled 148 patients with glaucoma (mean age 67 ± 11) and 71 controls (mean age 60 ± 10) in a clinical setting. This prototype pupillometer is designed to record and analyze pupillary responses at multiple, controlled stimulus intensities while using varied stimulus patterns and colors. We evaluated three approaches: (1) comparing the responses between the two eyes; (2) comparing responses to stimuli between the superonasal and inferonasal fields within each eye; and (3) calculating the absolute pupil response of each individual eye. Associative models were developed using stepwise regression or forward selection with Akaike information criterion and validated by fivefold cross-validation. We assessed the associative model using sensitivity, specificity and the area-under-the-receiver operating characteristic curve. RESULTS Persons with glaucoma had more asymmetric pupil responses in the two eyes (P < 0.001); between superonasal and inferonasal visual field within the same eye (P = 0.014); and smaller amplitudes, slower velocities and longer latencies of pupil responses compared to controls (all P < 0.001). A model including age and these three components resulted in an area-under-the-receiver operating characteristic curve of 0.87 (95% CI 0.83 to 0.92) with 80% sensitivity and specificity in detecting glaucoma. This result remained robust after cross-validation. CONCLUSIONS Using pupillography, we were able to discriminate among persons with glaucoma and those with normal eye examinations. With refinement, pupil testing may provide a simple approach for glaucoma screening.
Collapse
|
13
|
Sabeti F, James AC, Essex RW, Maddess T. Multifocal pupillography identifies retinal dysfunction in early age-related macular degeneration. Graefes Arch Clin Exp Ophthalmol 2013; 251:1707-16. [DOI: 10.1007/s00417-013-2273-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 12/17/2012] [Accepted: 01/22/2013] [Indexed: 10/27/2022] Open
|
14
|
Maddess T, Essex RW, Kolic M, Carle CF, James AC. High- versus low-density multifocal pupillographic objective perimetry in glaucoma. Clin Exp Ophthalmol 2013; 41:140-7. [DOI: 10.1111/ceo.12016] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Accepted: 10/01/2012] [Indexed: 11/30/2022]
Affiliation(s)
- Ted Maddess
- The ARC Vision Centre, John Curtin School of Medical Research, Australian National University, Australia.
| | | | | | | | | |
Collapse
|
15
|
Sabeti F, James AC, Essex RW, Maddess T. Dichoptic multifocal visual evoked potentials identify local retinal dysfunction in age-related macular degeneration. Doc Ophthalmol 2012; 126:125-36. [PMID: 23238587 DOI: 10.1007/s10633-012-9366-6] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2012] [Accepted: 12/03/2012] [Indexed: 10/27/2022]
Abstract
PURPOSE To evaluate the ability of multifocal visual evoked potentials (mfVEPs) to identify functional loss in patients with early and exudative age-related macular degeneration (AMD). A dichoptic multifocal stimulus presentation was employed to investigate the regional effects of AMD and the potential diagnostic utility in macular disease. METHODS MfVEP responses were recorded from 19 unilateral exudative AMD patients with non-exudative (n = 15) or normal (n = 4) presentations in the fellow eye and 28 age-matched controls. Root mean square (RMS) waveforms were pooled across selected EEG channels to produce global field RMS (gfRMS) waveforms. GfRMS amplitudes and response delays were analysed by multivariate linear models, and diagnostic capacity was measured using areas under the curve (AUC) of receiver operator characteristic plots. RESULTS The mean gfRMS amplitude of the exudative eye of AMD patients was significantly reduced compared with the controls (-2.03 ± 0.08 dB, t = -12.9). Fellow non-exudative AMD eyes were less effected but still significantly reduced (-0.84 ± 0.07 dB, t = -11.5). No significant difference in mean gfRMS delay of AMD eyes across the central 46° was observed. AUC values of 100 ± 0.0% (mean ± SE) for exudative and 79.7 ± 6.5% for non-exudative eyes were obtained for response amplitudes. CONCLUSION The study demonstrated that mfVEP identified retinal dysfunction in both exudative AMD and fellow non-exudative AMD eyes, but mostly affecting the macular field. The reduced testing duration and good diagnostic accuracy suggest that dichoptic mfVEPs may be a sensitive tool for monitoring progression in AMD.
Collapse
Affiliation(s)
- Faran Sabeti
- ARC Centre of Excellence in Vision Science, John Curtin School of Medical Research, The Australian National University, Canberra, ACT 0200, Australia.
| | | | | | | |
Collapse
|
16
|
Rosli Y, Bedford SM, James AC, Maddess T. Photopic and scotopic multifocal pupillographic responses in age-related macular degeneration. Vision Res 2012; 69:42-8. [PMID: 22898702 DOI: 10.1016/j.visres.2012.07.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2012] [Revised: 07/23/2012] [Accepted: 07/27/2012] [Indexed: 11/29/2022]
Abstract
We compared photopic and scotopic multifocal pupillographic stimuli in age-related macular degeneration (AMD). Both eyes of 18 normal and 14 AMD subjects were tested with four stimulus variants presented at photopic and 126 times lower luminances. The multifocal stimuli presented 24 test regions/eye to the central 60°. The stimulus variants had two different check sizes, and when presented either flickered (15 Hz) for 266 ms, or were steady for 133 ms. Mean differences from normal of 5 to 7 dB were observed in the central visual field for both photopic and scotopic stimuli (all p < 0.00002). The best areas under receiver operating characteristic plots for exudative AMD in the photopic and scotopic conditions were 92.9 ± 8.0 and 90.3 ± 5.7% respectively, and in less severely affected eyes 83.8 ± 9.7% and 76.9 ± 8.2%. Damage recorded at photopic levels was possibly more diffusely distributed across the visual field. Sensitivity and specificity was similar at photopic and scotopic levels.
Collapse
Affiliation(s)
- Y Rosli
- Program of Biomedical Science, School of Diagnostic and Applied Health Sciences, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur, Malaysia
| | | | | | | |
Collapse
|