Singhal S, Gurjar M, Sahoo JN, Saran S, Dua R, Sahoo AK, Sharma A, Agarwal S, Sharma A, Ghosh PS, Rao PB, Kothari N, Joshi K, Deokar K, Mukherjee S, Sharma P, Sreedevi BP, Sivaramakrishnan P, Singh U, Sundaram D, Agrawal A, Katoch CDS. Aerosol drug therapy in critically ill patients (Aero-in-ICU study): A multicentre prospective observational cohort study. Lung India 2024; 41:200-208. [PMID: 38687231 DOI: 10.4103/lungindia.lungindia_580_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Accepted: 02/23/2024] [Indexed: 05/02/2024] Open
Abstract
BACKGROUND In recent years, a significant understanding of delivering optimal aerosol therapy and the availability of various drugs and devices have led to an increase in its use in clinical practice. There are only a few studies available regarding their use in critically ill patients from a few parts of the world. We aimed to study the practice pattern of aerosol therapy in critically ill patients from Indian intensive care units (ICUs). METHODS After ethical approval, this multi-centric prospective observational study was performed over a study period of four weeks. Newly admitted adult patients considered who had an artificial airway and/or ventilation (including non-invasive). Patients were followed up for the next 14 days or until ICU discharge/death (whichever came first) for details of each aerosol therapy, including ongoing respiratory support, drug type, and aerosol-generating device. RESULTS From the nine participating centers across India, 218 patients were enrolled. Of 218 enrolled patients, 72.48% received 4884 aerosols with 30.91 ± 27.15 (95%CI: 26.6-35.1) aerosols per patient over 1108 patient days. Approximately 62.7% during IMV, 30.2% during NIV, 2.3% in spontaneously breathing patients with an artificial airway during weaning, and 4.7% were given without an artificial airway after weaning or decannulation. In 59%, a single drug was used, and bronchodilators were the most frequent. The jet nebulizer was the most common, followed by the ultrasonic and vibrating mesh aerosol generator. The ventilator setting was changed in only 6.6% of the aerosol sessions with IMV and none with NIV. CONCLUSION Aerosol therapy is frequently used with a wide variation in practices; bronchodilators are the most commonly used drugs, and jet nebulizers are the most widely used.
Collapse
Affiliation(s)
- Sanjay Singhal
- Pulmonary Medicine, All India Institute of Medical Science, Rajkot, Gujarat, India
| | - Mohan Gurjar
- Critical Care Medicine, Sanjay Gandhi Post Graduate Institute of Medical Sciences (SGPGIMS), Lucknow, Uttar Pradesh, India
| | - Jyoti Narayan Sahoo
- Department of Critical Care Medicine, Apollo Hospital, Bhubaneswar, Odisha, India
| | - Sai Saran
- Critical Care Medicine, King George's Medical University, Lucknow, Uttar Pradesh, India
| | - Ruchi Dua
- Pulmonary Medicine, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Alok Kumar Sahoo
- Anaesthesiology and Critical Care, All India Institute of Medical Sciences (AIIMS), Bhubaneswar, Odisha, India
| | - Ankur Sharma
- Trauma and Emergency (Anaesthesia and Critical Care), AIIMS Jodhpur, Rajasthan, India
| | - Sonika Agarwal
- Critical Care Medicine, HIMS, SRHU, Dehradun, Uttarakhand, India
| | | | | | | | - Nikhil Kothari
- Anaesthesia and Critical Care, AIIMS Jodhpur, Rajasthan, India
| | - Krupal Joshi
- Community and Family Medicine, All India Institute of Medical Sciences, Rajkot, Gujarat, India
| | - Kunal Deokar
- Pulmonary Medicine, All India Institute of Medical Science, Rajkot, Gujarat, India
| | | | - Prakhar Sharma
- Pulmonary Medicine, All India Institute of Medical Sciences, Rishikesh, Uttarakhand, India
| | - Billa Ps Sreedevi
- Critical Care Medicine, King George's Medical University, Lucknow, Uttar Pradesh, India
| | | | - Umadri Singh
- Critical Care Medicine, Sanjay Gandhi Post Graduate Institute of Medical Sciences (SGPGIMS), Lucknow, Uttar Pradesh, India
| | - Dhivya Sundaram
- Anaesthesia and Critical Care, AIIMS Jodhpur, Rajasthan, India
| | - Avinash Agrawal
- Critical Care Medicine, King George's Medical University, Lucknow, Uttar Pradesh, India
| | | |
Collapse
|
2
|
Reilly L, Mac Giolla Eain M, Murphy S, O’Sullivan A, Joyce M, MacLoughlin R. An in vitro study of the effects of respiratory circuit setup and parameters on aerosol delivery during mechanical ventilation. Front Med (Lausanne) 2024; 10:1307301. [PMID: 38327274 PMCID: PMC10847248 DOI: 10.3389/fmed.2023.1307301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/26/2023] [Indexed: 02/09/2024] Open
Abstract
Introduction Aerosol therapy is often prescribed concurrently during invasive mechanical ventilation (IMV). This study determines the effects of nebuliser position, circuit humidification source, and most importantly, lung health on the delivery of aerosol in simulated adult and paediatric IMV patients. Furthermore, the influence of closed suction catheters on aerosol delivery is also addressed. Methods A vibrating mesh nebuliser was used to deliver Albuterol to simulated adult and paediatric IMV patients with differing states of lung health. Four different nebuliser positions and two types of humidification were analysed. Closed suction catheter mounts, a mainstay in IMV therapy, were incorporated into the circuits. The mean ± SD dose of aerosol (%) was assayed from a filter at the distal end of the endotracheal tube. Results Nebuliser placement and circuit humidification source had no effect on the delivered dose (%) in adults, yet both significantly did in the simulated paediatric patients. The use of closed suction catheter mounts significantly reduced the delivered dose (%) in adults but not in paediatric patients. A simulated healthy lung state generated the largest delivered dose (%), irrespective of nebuliser position in the adult. However, different lung health and nebuliser positions yielded higher delivered doses (%) in paediatrics. Conclusion Lung health and respiratory circuit composition significantly affect aerosol delivery in both adult and paediatric IMV patients. Nebuliser placement and respiratory circuit humidification source do not affect the delivered dose in adult but do in paediatric IMV patients.
Collapse
Affiliation(s)
- Leanne Reilly
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Marc Mac Giolla Eain
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Sarah Murphy
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Andrew O’Sullivan
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Mary Joyce
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
| | - Ronan MacLoughlin
- Research and Development, Science and Emerging Technologies, Aerogen Ltd., Galway Business Park, Galway, Ireland
- School of Pharmacy & Biomolecular Science, Royal College of Surgeons in Ireland, Dublin, Ireland
- School of Pharmacy and Pharmaceutical Sciences, Trinty College, Dublin, Ireland
| |
Collapse
|
3
|
Katiyar SK, Gaur SN, Solanki RN, Sarangdhar N, Suri JC, Kumar R, Khilnani GC, Chaudhary D, Singla R, Koul PA, Mahashur AA, Ghoshal AG, Behera D, Christopher DJ, Talwar D, Ganguly D, Paramesh H, Gupta KB, Kumar T M, Motiani PD, Shankar PS, Chawla R, Guleria R, Jindal SK, Luhadia SK, Arora VK, Vijayan VK, Faye A, Jindal A, Murar AK, Jaiswal A, M A, Janmeja AK, Prajapat B, Ravindran C, Bhattacharyya D, D'Souza G, Sehgal IS, Samaria JK, Sarma J, Singh L, Sen MK, Bainara MK, Gupta M, Awad NT, Mishra N, Shah NN, Jain N, Mohapatra PR, Mrigpuri P, Tiwari P, Narasimhan R, Kumar RV, Prasad R, Swarnakar R, Chawla RK, Kumar R, Chakrabarti S, Katiyar S, Mittal S, Spalgais S, Saha S, Kant S, Singh VK, Hadda V, Kumar V, Singh V, Chopra V, B V. Indian Guidelines on Nebulization Therapy. Indian J Tuberc 2022; 69 Suppl 1:S1-S191. [PMID: 36372542 DOI: 10.1016/j.ijtb.2022.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2022] [Revised: 06/03/2022] [Accepted: 06/09/2022] [Indexed: 06/16/2023]
Abstract
Inhalational therapy, today, happens to be the mainstay of treatment in obstructive airway diseases (OADs), such as asthma, chronic obstructive pulmonary disease (COPD), and is also in the present, used in a variety of other pulmonary and even non-pulmonary disorders. Hand-held inhalation devices may often be difficult to use, particularly for children, elderly, debilitated or distressed patients. Nebulization therapy emerges as a good option in these cases besides being useful in the home care, emergency room and critical care settings. With so many advancements taking place in nebulizer technology; availability of a plethora of drug formulations for its use, and the widening scope of this therapy; medical practitioners, respiratory therapists, and other health care personnel face the challenge of choosing appropriate inhalation devices and drug formulations, besides their rational application and use in different clinical situations. Adequate maintenance of nebulizer equipment including their disinfection and storage are the other relevant issues requiring guidance. Injudicious and improper use of nebulizers and their poor maintenance can sometimes lead to serious health hazards, nosocomial infections, transmission of infection, and other adverse outcomes. Thus, it is imperative to have a proper national guideline on nebulization practices to bridge the knowledge gaps amongst various health care personnel involved in this practice. It will also serve as an educational and scientific resource for healthcare professionals, as well as promote future research by identifying neglected and ignored areas in this field. Such comprehensive guidelines on this subject have not been available in the country and the only available proper international guidelines were released in 1997 which have not been updated for a noticeably long period of over two decades, though many changes and advancements have taken place in this technology in the recent past. Much of nebulization practices in the present may not be evidence-based and even some of these, the way they are currently used, may be ineffective or even harmful. Recognizing the knowledge deficit and paucity of guidelines on the usage of nebulizers in various settings such as inpatient, out-patient, emergency room, critical care, and domiciliary use in India in a wide variety of indications to standardize nebulization practices and to address many other related issues; National College of Chest Physicians (India), commissioned a National task force consisting of eminent experts in the field of Pulmonary Medicine from different backgrounds and different parts of the country to review the available evidence from the medical literature on the scientific principles and clinical practices of nebulization therapy and to formulate evidence-based guidelines on it. The guideline is based on all possible literature that could be explored with the best available evidence and incorporating expert opinions. To support the guideline with high-quality evidence, a systematic search of the electronic databases was performed to identify the relevant studies, position papers, consensus reports, and recommendations published. Rating of the level of the quality of evidence and the strength of recommendation was done using the GRADE system. Six topics were identified, each given to one group of experts comprising of advisors, chairpersons, convenor and members, and such six groups (A-F) were formed and the consensus recommendations of each group was included as a section in the guidelines (Sections I to VI). The topics included were: A. Introduction, basic principles and technical aspects of nebulization, types of equipment, their choice, use, and maintenance B. Nebulization therapy in obstructive airway diseases C. Nebulization therapy in the intensive care unit D. Use of various drugs (other than bronchodilators and inhaled corticosteroids) by nebulized route and miscellaneous uses of nebulization therapy E. Domiciliary/Home/Maintenance nebulization therapy; public & health care workers education, and F. Nebulization therapy in COVID-19 pandemic and in patients of other contagious viral respiratory infections (included later considering the crisis created due to COVID-19 pandemic). Various issues in different sections have been discussed in the form of questions, followed by point-wise evidence statements based on the existing knowledge, and recommendations have been formulated.
Collapse
Affiliation(s)
- S K Katiyar
- Department of Tuberculosis & Respiratory Diseases, G.S.V.M. Medical College & C.S.J.M. University, Kanpur, Uttar Pradesh, India.
| | - S N Gaur
- Vallabhbhai Patel Chest Institute, University of Delhi, Respiratory Medicine, School of Medical Sciences and Research, Sharda University, Greater NOIDA, Uttar Pradesh, India
| | - R N Solanki
- Department of Tuberculosis & Chest Diseases, B. J. Medical College, Ahmedabad, Gujarat, India
| | - Nikhil Sarangdhar
- Department of Pulmonary Medicine, D. Y. Patil School of Medicine, Navi Mumbai, Maharashtra, India
| | - J C Suri
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - Raj Kumar
- Vallabhbhai Patel Chest Institute, Department of Pulmonary Medicine, National Centre of Allergy, Asthma & Immunology; University of Delhi, Delhi, India
| | - G C Khilnani
- PSRI Institute of Pulmonary, Critical Care, & Sleep Medicine, PSRI Hospital, Department of Pulmonary Medicine & Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Dhruva Chaudhary
- Department of Pulmonary & Critical Care Medicine, Pt. Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences, Rohtak, Haryana, India
| | - Rupak Singla
- Department of Tuberculosis & Respiratory Diseases, National Institute of Tuberculosis & Respiratory Diseases (formerly L.R.S. Institute), Delhi, India
| | - Parvaiz A Koul
- Sher-i-Kashmir Institute of Medical Sciences, Srinagar, Jammu & Kashmir, India
| | - Ashok A Mahashur
- Department of Respiratory Medicine, P. D. Hinduja Hospital, Mumbai, Maharashtra, India
| | - A G Ghoshal
- National Allergy Asthma Bronchitis Institute, Kolkata, West Bengal, India
| | - D Behera
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - D J Christopher
- Department of Pulmonary Medicine, Christian Medical College, Vellore, Tamil Nadu, India
| | - Deepak Talwar
- Metro Centre for Respiratory Diseases, Noida, Uttar Pradesh, India
| | | | - H Paramesh
- Paediatric Pulmonologist & Environmentalist, Lakeside Hospital & Education Trust, Bengaluru, Karnataka, India
| | - K B Gupta
- Department of Tuberculosis & Respiratory Medicine, Pt. Bhagwat Dayal Sharma Post Graduate Institute of Medical Sciences Rohtak, Haryana, India
| | - Mohan Kumar T
- Department of Pulmonary, Critical Care & Sleep Medicine, One Care Medical Centre, Coimbatore, Tamil Nadu, India
| | - P D Motiani
- Department of Pulmonary Diseases, Dr. S. N. Medical College, Jodhpur, Rajasthan, India
| | - P S Shankar
- SCEO, KBN Hospital, Kalaburagi, Karnataka, India
| | - Rajesh Chawla
- Respiratory and Critical Care Medicine, Indraprastha Apollo Hospitals, New Delhi, India
| | - Randeep Guleria
- All India Institute of Medical Sciences, Department of Pulmonary Medicine & Sleep Disorders, AIIMS, New Delhi, India
| | - S K Jindal
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - S K Luhadia
- Department of Tuberculosis and Respiratory Medicine, Geetanjali Medical College and Hospital, Udaipur, Rajasthan, India
| | - V K Arora
- Indian Journal of Tuberculosis, Santosh University, NCR Delhi, National Institute of TB & Respiratory Diseases Delhi, India; JIPMER, Puducherry, India
| | - V K Vijayan
- Vallabhbhai Patel Chest Institute, Department of Pulmonary Medicine, University of Delhi, Delhi, India
| | - Abhishek Faye
- Centre for Lung and Sleep Disorders, Nagpur, Maharashtra, India
| | | | - Amit K Murar
- Respiratory Medicine, Cronus Multi-Specialty Hospital, New Delhi, India
| | - Anand Jaiswal
- Respiratory & Sleep Medicine, Medanta Medicity, Gurugram, Haryana, India
| | - Arunachalam M
- All India Institute of Medical Sciences, New Delhi, India
| | - A K Janmeja
- Department of Respiratory Medicine, Government Medical College, Chandigarh, India
| | - Brijesh Prajapat
- Pulmonary and Critical Care Medicine, Yashoda Hospital and Research Centre, Ghaziabad, Uttar Pradesh, India
| | - C Ravindran
- Department of TB & Chest, Government Medical College, Kozhikode, Kerala, India
| | - Debajyoti Bhattacharyya
- Department of Pulmonary Medicine, Institute of Liver and Biliary Sciences, Army Hospital (Research & Referral), New Delhi, India
| | | | - Inderpaul Singh Sehgal
- Department of Pulmonary Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh, India
| | - J K Samaria
- Centre for Research and Treatment of Allergy, Asthma & Bronchitis, Department of Chest Diseases, IMS, BHU, Varanasi, Uttar Pradesh, India
| | - Jogesh Sarma
- Department of Pulmonary Medicine, Gauhati Medical College and Hospital, Guwahati, Assam, India
| | - Lalit Singh
- Department of Respiratory Medicine, SRMS Institute of Medical Sciences, Bareilly, Uttar Pradesh, India
| | - M K Sen
- Department of Respiratory Medicine, ESIC Medical College, NIT Faridabad, Haryana, India; Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - Mahendra K Bainara
- Department of Pulmonary Medicine, R.N.T. Medical College, Udaipur, Rajasthan, India
| | - Mansi Gupta
- Department of Pulmonary Medicine, Sanjay Gandhi PostGraduate Institute of Medical Sciences, Lucknow, Uttar Pradesh, India
| | - Nilkanth T Awad
- Department of Pulmonary Medicine, Lokmanya Tilak Municipal Medical College, Mumbai, Maharashtra, India
| | - Narayan Mishra
- Department of Pulmonary Medicine, M.K.C.G. Medical College, Berhampur, Orissa, India
| | - Naveed N Shah
- Department of Pulmonary Medicine, Chest Diseases Hospital, Government Medical College, Srinagar, Jammu & Kashmir, India
| | - Neetu Jain
- Department of Pulmonary, Critical Care & Sleep Medicine, PSRI, New Delhi, India
| | - Prasanta R Mohapatra
- Department of Pulmonary Medicine & Critical Care, All India Institute of Medical Sciences, Bhubaneswar, Orissa, India
| | - Parul Mrigpuri
- Department of Pulmonary Medicine, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | - Pawan Tiwari
- School of Excellence in Pulmonary Medicine, NSCB Medical College, Jabalpur, Madhya Pradesh, India
| | - R Narasimhan
- Department of EBUS and Bronchial Thermoplasty Services at Apollo Hospitals, Chennai, Tamil Nadu, India
| | - R Vijai Kumar
- Department of Pulmonary Medicine, MediCiti Medical College, Hyderabad, Telangana, India
| | - Rajendra Prasad
- Vallabhbhai Patel Chest Institute, University of Delhi and U.P. Rural Institute of Medical Sciences & Research, Safai, Uttar Pradesh, India
| | - Rajesh Swarnakar
- Department of Respiratory, Critical Care, Sleep Medicine and Interventional Pulmonology, Getwell Hospital & Research Institute, Nagpur, Maharashtra, India
| | - Rakesh K Chawla
- Department of, Respiratory Medicine, Critical Care, Sleep & Interventional Pulmonology, Saroj Super Speciality Hospital, Jaipur Golden Hospital, Rajiv Gandhi Cancer Hospital, Delhi, India
| | - Rohit Kumar
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | - S Chakrabarti
- Department of Pulmonary, Critical Care & Sleep Medicine, Vardhman Mahavir Medical College & Safdarjung Hospital, New Delhi, India
| | | | - Saurabh Mittal
- Department of Pulmonary, Critical Care & Sleep Medicine, All India Institute of Medical Sciences, New Delhi, India
| | - Sonam Spalgais
- Department of Pulmonary Medicine, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | | | - Surya Kant
- Department of Respiratory (Pulmonary) Medicine, King George's Medical University, Lucknow, Uttar Pradesh, India
| | - V K Singh
- Centre for Visceral Mechanisms, Vallabhbhai Patel Chest Institute, University of Delhi, Delhi, India
| | - Vijay Hadda
- Department of Pulmonary Medicine & Sleep Disorders, All India Institute of Medical Sciences, New Delhi, India
| | - Vikas Kumar
- All India Institute of Medical Sciences, Raipur, Chhattisgarh, India
| | - Virendra Singh
- Mahavir Jaipuria Rajasthan Hospital, Jaipur, Rajasthan, India
| | - Vishal Chopra
- Department of Chest & Tuberculosis, Government Medical College, Patiala, Punjab, India
| | - Visweswaran B
- Interventional Pulmonology, Yashoda Hospitals, Hyderabad, Telangana, India
| |
Collapse
|
4
|
Mac Giolla Eain M, O'Sullivan A, Joyce M, MacLoughlin R. In vitro evaluation of disposable transport ventilators with combination aerosol therapy. BMJ Open Respir Res 2021; 8:8/1/e000739. [PMID: 33771812 PMCID: PMC8006849 DOI: 10.1136/bmjresp-2020-000739] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 11/30/2020] [Accepted: 03/13/2021] [Indexed: 11/17/2022] Open
Abstract
Background The COVID-19 pandemic has highlighted the need for alternative short-term, reliable means to aid in the treatment of patients requiring ventilatory support. Concurrent aerosol drug delivery is often prescribed to such patients. As such, this study examines one such short-term option, the disposable gas-powered transport ventilator to effectively deliver aerosol therapy. Factors such as aerosol generator type, patient breathing pattern, humidification and nebuliser position within the respiratory circuit were also examined. Methods Aerosol drug delivery characterisation was undertaken using two different disposable transport ventilators (DTVs). Two different nebuliser types, a closed circuit vibrating mesh nebuliser (VMN) and an open circuit jet nebuliser (JN), at different locations in a respiratory circuit, proximal and distal to an endotracheal tube (ETT), with and without passive humidification, were evaluated in simulated adult and paediatric patients. Results Placement of a nebuliser proximal to the ETT (VMN: 25.19%–34.15% and JN: 3.14%–8.92%), and the addition of a heat and moisture exchange filter (VMN: 32.37%–40.43% and JN: 5.60%–9.91%) resulted in the largest potential lung dose in the adult patient model. Irrespective of nebuliser position and humidification in the respiratory circuit, use of the VMN resulted in the largest potential lung dose (%). A similar trend was recorded in the paediatric model data, where the largest potential lung dose was recorded with both nebuliser types placed proximal to the ETT (VMN: 8.12%–10.89% and JN: 2.15%–3.82%). However, the addition of a heat and moisture exchange filter had no statistically significant effect on the potential lung dose (%) a paediatric patient would receive (p>>0.05). Conclusions This study demonstrates that transport ventilators, such as DTVs, can be used concurrently with aerosol generators to effectively deliver aerosolised medication in both adult and paediatric patients.
Collapse
Affiliation(s)
| | | | - Mary Joyce
- R&D Science and Emerging Technologies, Aerogen Ltd, Galway, Ireland
| | | |
Collapse
|
5
|
Li J, Wu W, Fink JB. In vitro comparison between inspiration synchronized and continuous vibrating mesh nebulizer during trans-nasal aerosol delivery. Intensive Care Med Exp 2020; 8:6. [PMID: 32006290 PMCID: PMC6994578 DOI: 10.1186/s40635-020-0293-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 01/14/2020] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Compared to continuous vibrating mesh nebulizer (VMN), inspiration synchronized VMN has shown increased inhaled dose during noninvasive ventilation; however, its use during aerosol delivery via high-flow nasal cannula (HFNC) is still unknown. METHODS An adult manikin was connected to a dual-chamber model lung, which was driven by a critical care ventilator to simulate spontaneous breathing. A HFNC system was utilized with temperature at 37 ° C while gas flow at 5, 10, 20, 40, and 60 L/min. Inspiration synchronized and continuous aerosol generation were compared at different positions (at the inlet of humidifier vs close to patient). One milliliter of albuterol (2.5 mg/mL) was used in each run (n = 3). Collection filter was placed at the trachea and was removed after each run. Drug was eluted from the filter and assayed with UV spectrophotometry (276 nm). RESULTS When nebulizer was placed close to patient, inhaled dose was higher with inspiration synchronized than continuous aerosol generation at all gas flows (p = 0.05) except at 5 L/min. When placed at the inlet of humidifier, compared to continuous, inspiration synchronized aerosol generated higher inhaled dose with gas flow set below 50% of patient inspiratory flow [23.9 (20.6, 28.3)% vs 18.1 (16.7, 19.6)%, p < 0.001], but lower inhaled dose with gas flow set above 50% of patient inspiratory flow [3.5 (2.2, 9.3)% vs 9.9 (8.2, 16.4)%, p = 0.001]. Regardless of breathing pattern, continuous aerosol delivered greater inhaled dose with nebulizer placed at humidifier than close to patient at all gas flows except at 5 L/min. CONCLUSION When the HFNC gas flow was set higher than 50% of patient inspiratory flow, no significant advantage was found in inspiration synchronized over continuous aerosol. However, inspiration synchronized aerosol generated 30% more inhaled dose than continuous with gas flow set below 50% of patient inspiratory flow, regardless of nebulizer placement. Continuous nebulizer needs to be placed at the inlet of humidifier.
Collapse
Affiliation(s)
- Jie Li
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA.
| | - Wei Wu
- Department of Critical Care Medicine, Shanghai Zhongshan Hospital, Fu Dan University, Shanghai, China
| | - James B Fink
- Department of Cardiopulmonary Sciences, Division of Respiratory Care, Rush University Medical Center, 1620 W Harrison St, Tower LL1202, Chicago, IL, 60612, USA
- Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
6
|
Ari A, Fink JB. Recent advances in aerosol devices for the delivery of inhaled medications. Expert Opin Drug Deliv 2020; 17:133-144. [PMID: 31959028 DOI: 10.1080/17425247.2020.1712356] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Introduction: Aerosolized medications are commonly prescribed for the treatment of patients with pulmonary diseases, and there has been an increased interest in the development of aerosol delivery devices over the years. Technical innovations have advanced device design, novel features such as breath actuation, dose tracking, portability, and feedback mechanism during treatment that improved the performance of aerosol devices, and effectiveness of inhalation therapy.Areas covered: The purpose of this paper is to review recent advances in aerosol devices for delivery of inhaled medications.Expert opinion: Drug formulations and device designs are rapidly evolving to make more consistent dosing across a broad range of inspiratory efforts, to maximize dose and target specific areas of the diseased lung.
Collapse
Affiliation(s)
- Arzu Ari
- Department of Respiratory Care, Texas State University, College of Health Professions, Round Rock, TX, USA
| | - James B Fink
- Department of Respiratory Care, Texas State University, College of Health Professions, Round Rock, TX, USA.,Aerogen Pharma Corp, San Mateo, CA, USA
| |
Collapse
|
7
|
Stylianou E, Paul MJ, Reljic R, McShane H. Mucosal delivery of tuberculosis vaccines: a review of current approaches and challenges. Expert Rev Vaccines 2019; 18:1271-1284. [PMID: 31876199 PMCID: PMC6961305 DOI: 10.1080/14760584.2019.1692657] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Introduction: Tuberculosis (TB) remains a major health threat and it is now clear that the current vaccine, BCG, is unable to arrest the global TB epidemic. A new vaccine is needed to either replace or boost BCG so that a better level of protection could be achieved. The route of entry of Mycobacterium tuberculosis, the causative organism, is via inhalation making TB primarily a respiratory disease. There is therefore good reason to hypothesize that a mucosally delivered vaccine against TB could be more effective than one delivered via the systemic route. Areas covered: This review summarizes the progress that has been made in the area of TB mucosal vaccines in the last few years. It highlights some of the strengths and shortcomings of the published evidence and aims to discuss immunological and practical considerations in the development of mucosal vaccines. Expert opinion: There is a growing body of evidence that the mucosal approach to vaccination against TB is feasible and should be pursued. However, further key studies are necessary to both improve our understanding of the protective immune mechanisms operating in the mucosa and the technical aspects of aerosolized delivery, before such a vaccine could become a feasible, deployable strategy.
Collapse
Affiliation(s)
- Elena Stylianou
- The Jenner Institute, Nuffield Department of Medicine, University of Oxford, Oxford, UK
| | - Matthew J Paul
- Institute for Infection and Immunity, St George's University of London, Tooting, London, UK
| | - Rajko Reljic
- Institute for Infection and Immunity, St George's University of London, Tooting, London, UK
| | - Helen McShane
- The Jenner Institute, Nuffield Department of Medicine, University of Oxford, Oxford, UK
| |
Collapse
|
8
|
Yang SH, Yang TM, Lin HL, Tsai YH, Fang TP, Wan GH. Size distribution of salbutamol/ipratropium aerosols produced by different nebulizers in the absence and presence of heat and humidification. Pulm Pharmacol Ther 2017; 48:22-27. [PMID: 29054517 DOI: 10.1016/j.pupt.2017.10.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/31/2017] [Revised: 10/12/2017] [Accepted: 10/16/2017] [Indexed: 11/17/2022]
Abstract
BACKGROUND Few studies have evaluated the size distribution of inhaled and exhaled aerosolized drugs, or the effect of heated humidification on particle size and lung deposition. The present study evaluated these aspects of bronchodilator (salbutamol/ipratropium) delivery using a lung model in the absence and presence of heat and humidification. METHODS We positioned filters to collect and measure the initial drug, inhaled drug, and exhaled drug. Particle size distribution was evaluated using an 8-stage Marple personal cascade impactor with 0.2-μm polycarbonate filters. RESULTS A greater inhaled drug mass was delivered using a vibrating mesh nebulizer (VMN) than by using a small volume nebulizer (SVN), when heated humidifiers were not employed. When heated and humidified medical gas was used, there was no significant difference between the inhaled drug mass delivered by the VMN and that delivered by the SVN. A significantly greater mass of inhaled 1.55-μm drug particles was produced by the VMN than with the SVN, under heated and humidified conditions. However, the mass median aerodynamic diameters (MMADs) of the aerosolized drug produced by the SVN and VMN did not differ significantly under the same conditions. CONCLUSIONS The VMN produced more fine particles of salbutamol/ipratropium, and the drug particle size clearly increased in the presence of heat and humidification.
Collapse
Affiliation(s)
- Ssu-Han Yang
- Graduate Institute of Clinical Medicine, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Respiratory Therapy Team of Chest Department, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Tsung-Ming Yang
- Department of Pulmonary and Critical Care, Chiayi Chang Gung Memorial Hospital, Chiayi, Taiwan
| | - Hui-Ling Lin
- Department of Respiratory Therapy, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Department of Respiratory Therapy, Chang Gung University of Science and Technology, Chiayi, Taiwan; Department of Respiratory Therapy, Chiayi Chang Gung Memorial Hospital, Chiayi, Taiwan
| | - Ying-Huang Tsai
- Department of Pulmonary and Critical Care, Chiayi Chang Gung Memorial Hospital, Chiayi, Taiwan; Department of Respiratory Therapy, Chiayi Chang Gung Memorial Hospital, Chiayi, Taiwan
| | - Tien-Pei Fang
- Department of Respiratory Therapy, Chiayi Chang Gung Memorial Hospital, Chiayi, Taiwan
| | - Gwo-Hwa Wan
- Department of Respiratory Therapy, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Department of Respiratory Therapy, Chang Gung University of Science and Technology, Chiayi, Taiwan; Department of Neurosurgery, Linkuo Chang Gung Memorial Hospital, Taoyuan, Taiwan.
| |
Collapse
|
9
|
Holbrook L, Hindle M, Longest PW. In Vitro Assessment of Small Charged Pharmaceutical Aerosols in a Model of a Ventilated Neonate. JOURNAL OF AEROSOL SCIENCE 2017; 110:25-35. [PMID: 29276307 PMCID: PMC5737757 DOI: 10.1016/j.jaerosci.2017.05.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Aerosolized medications may benefit infants receiving mechanical ventilation; however, the lung delivery efficiency of these aerosols is unacceptably low. In vitro experiments were conducted to evaluate aerosol delivery through conventional and modified ventilation systems to the end of a 3mm endotracheal tube (ETT) under steady state and realistic cyclic flow conditions. System modifications were employed to investigate the use of small charged particles and included streamlined components, a reduction in nebulizer liquid flow rate, synchronization with inspiration, and implementation of a previously designed low-flow induction charger (LF-IC), which was further modified in this study. Cyclic flow experiments implemented a modern ventilator with bias airflow and an inline flow meter, both of which are frequently excluded from in vitro tests but included in clinical practice. The modified LF-IC system demonstrated superior delivery efficiency to the end of the ETT (34%) compared with the commercial system (~1.3%) operating under cyclic ventilation conditions. These findings indicate that commercial systems still provide very low lung delivery efficiencies despite decades of innovation. In contrast, the modified system increased dose delivery to the end of the ETT by 26-fold. Despite initial concerns, the charged aerosol could be efficiently delivered through the small diameter ETT and reach the lungs. Future studies will be required to determine if the applied particle charge can eliminate expected high exhalation aerosol loss and will require the development of a realistic lung model.
Collapse
Affiliation(s)
- Landon Holbrook
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
10
|
ElHansy MHE, Boules ME, Farid H, Chrystyn H, El-Maraghi SK, Al-Kholy MB, El-Essawy AFM, Abdelrahman MM, Said ASA, Hussein RRS, Rabea H, Abdelrahim MEA. In vitro aerodynamic characteristics of aerosol delivered from different inhalation methods in mechanical ventilation. Pharm Dev Technol 2016; 22:844-849. [PMID: 27493018 DOI: 10.1080/10837450.2016.1221427] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Aerodynamic characteristics of aerosol delivery during invasive mechanical ventilation (IMV) are mostly determined by inserting cascade impactor in the circuit. Impactor might have some effect on airflow within IMV. Hence, the aim of the present study was to develop and evaluate new in vitro aerodynamic characterization methodology without affecting airflow in IMV. Breathing simulator was set in standard adult IMV circuit with inspiratory and expiratory pressures of 20 and 5 cm H2O, 1:3 inspiratory-expiratory ratio, 15 breaths min-1, and tidal volume of 500 ml. Two ml of salbutamol solution containing 10,000 μg was nebulized using three different vibrating mesh nebulizers (VMNs) and Sidestream jet nebulizer (JET). Sixteen-metered doses, containing 100 μg salbutamol each, were delivered using three different spacers. Each device was placed in inspiration limb of Y-piece of ventilator tubing. Aerodynamic characteristics of aerosol delivered were measured using cooled Andersen cascade impactor, with mixing inlet connected to it. VMNs used had significantly more total mass in the impactor (p < .001) and fine particle dose (p < .001) compared to JET. Spacers used had higher total mass in the impactor percent (p < .001) and fine particle fraction compared to nebulizers. The in vitro IMV methodology setting suggested here showed encouraging results in comparison of different aerosol delivery systems in intubated patient.
Collapse
Affiliation(s)
- Muhammad H E ElHansy
- a Department of Clinical Pharmacy, Teaching Hospital of Faculty of Medicine , Fayoum University , Fayoum , Egypt
| | - Marina E Boules
- b Department of Clinical Pharmacy, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| | - Heba Farid
- c Department of Clinical Pharmacy, Teaching Hospital of Faculty of Medicine , Beni-Suef University , Beni-Suef , Egypt
| | - Henry Chrystyn
- d Inhalation Consultancy Ltd. , Leeds , UK.,e Faculty of Health and Human Sciences, Plymouth University , Plymouth , UK
| | - Sameh Kamal El-Maraghi
- f Department of Critical Care, Faculty of Medicine , Beni-Suef University , Beni-Suef , Egypt
| | - Mohamed Bakry Al-Kholy
- f Department of Critical Care, Faculty of Medicine , Beni-Suef University , Beni-Suef , Egypt
| | | | - Maha M Abdelrahman
- h Department of Analytical Chemistry, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| | - Amira S A Said
- b Department of Clinical Pharmacy, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| | - Raghda R S Hussein
- b Department of Clinical Pharmacy, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| | - Hoda Rabea
- b Department of Clinical Pharmacy, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| | - Mohamed E A Abdelrahim
- b Department of Clinical Pharmacy, Faculty of Pharmacy , Beni-Suef University , Beni-Suef , Egypt
| |
Collapse
|
11
|
Ari A, Fink JB. Differential Medical Aerosol Device and Interface Selection in Patients during Spontaneous, Conventional Mechanical and Noninvasive Ventilation. J Aerosol Med Pulm Drug Deliv 2016; 29:95-106. [DOI: 10.1089/jamp.2015.1266] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Affiliation(s)
- Arzu Ari
- Division of Respiratory Therapy, Georgia State University, Atlanta, Georgia
| | - James B. Fink
- Division of Respiratory Therapy, Georgia State University, Atlanta, Georgia
| |
Collapse
|
12
|
Xi J, Yuan JE, Si XA. Simulation study of electric-guided delivery of 0.4µm monodisperse and polydisperse aerosols to the ostiomeatal complex. Comput Biol Med 2016; 72:1-12. [PMID: 26969803 DOI: 10.1016/j.compbiomed.2016.03.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2016] [Revised: 03/02/2016] [Accepted: 03/02/2016] [Indexed: 10/22/2022]
Abstract
Despite the high prevalence of rhinosinusitis, current inhalation therapy shows limited efficacy due to extremely low drug delivery efficiency to the paranasal sinuses. Novel intranasal delivery systems are needed to enhance targeted delivery to the sinus with therapeutic dosages. An optimization framework for intranasal drug delivery was developed to target polydisperse charged aerosols to the ostiomeatal complex (OMC) with electric guidance. The delivery efficiency of a group of charged aerosols recently reported in the literature was numerically assessed and optimized in an anatomically accurate nose-sinus model. Key design variables included particle charge number, particle size and distribution, electrode strength, and inhalation velocity. Both monodisperse and polydisperse aerosol profiles were considered. Results showed that the OMC delivery efficiency was highly sensitive to the applied electric field and electrostatic charges carried by the particles. Through the synthesis of electric-guidance and point drug release, focused deposition with significantly enhanced dosage in the OMC can be achieved. For 0.4 µm charged aerosols, an OMC delivery efficiency of 51.6% was predicted for monodisperse aerosols and 34.4% for polydisperse aerosols. This difference suggested that the aerosol profile exerted a notable effect on intranasal deliveries. Sensitivity analysis indicated that the OMC deposition fraction was highly sensitive to the charge and size of particles and was less sensitive to the inhalation velocity considered in this study. Experimental studies are needed to validate the numerically optimized designs. Further studies are warranted to investigate the targeted OMC delivery with both electric and acoustics controls, the latter of which has the potential to further deliver the drug particles into the sinus cavity.
Collapse
Affiliation(s)
- Jinxiang Xi
- School of Engineering and Technology, Central Michigan University, 1200 South Franklin Street, Mount Pleasant, MI 48858, USA.
| | - Jiayao Eddie Yuan
- School of Engineering and Technology, Central Michigan University, 1200 South Franklin Street, Mount Pleasant, MI 48858, USA
| | - Xiuhua April Si
- Department of Mechanical Engineering, California Baptist University, Riverside, CA, USA
| |
Collapse
|
13
|
Inhaled Drug Delivery for Children on Long-term Mechanical Ventilation. Respir Med 2016. [DOI: 10.1007/978-1-4939-3749-3_11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
Holbrook L, Hindle M, Longest PW. Generating Charged Pharmaceutical Aerosols Intended to Improve Targeted Drug Delivery in Ventilated Infants. JOURNAL OF AEROSOL SCIENCE 2015; 88:35-47. [PMID: 26273108 PMCID: PMC4530998 DOI: 10.1016/j.jaerosci.2015.05.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
The delivery of pharmaceutical aerosols to infants receiving mechanical ventilation is extremely challenging due to small diameter flow passages, low tidal volumes, and frequent exhalation of the aerosol. The use of small charged particles is proposed as a novel method to prevent deposition in ventilator components and foster deposition in the lower infant airways. The objective of this study was to compare the performance of multiple new devices for generating small charged particles that are expected to maximize respiratory drug delivery in ventilated infants. Criteria used to select a leading device included production of a charged aerosol with a mass median aerodynamic diameter (MMAD) ≤ approximately 1.8 μm; low device depositional loss of the aerosol (<20%); particle charge in the range of the Rayleigh limit/100; and high drug output with low performance variability. Proposed new devices were a wick electrospray (WES) system with accelerated cross-flow air; a condensational vapor (CV) system with a charged solution and strong field gradient; and a low flow - induction charger (LF-IC) designed to operate with a modified commercial mesh nebulizer. Based on infant ventilation conditions, flow rates through the devices were in a range of 2-5 L/min and the devices were assessed in terms of depositional drug loss and emitted drug mass; droplet size distribution (DSD) using a Mini-MOUDI; and DSD and net charge with a modified ELPI. Considering the WES, primary limitations were (i) low and variable aerosol production rates and (ii) high device depositional losses. The CV device produced a high quality aerosol with a MMAD of 0.14 μm and a drug delivery rate of 25 μg/min. However, the device was excluded because it failed to produce a charged aerosol. In contrast, the LF-IC produced a 1.6 μm aerosol with high net charge, low device depositional loss (<15% based on recovery), and low variability. In the ELPI size fraction bin nearest the MMAD, the LF-IC produced >100 elementary charges per particle, which was an order of magnitude increase compared to the case of zero charging voltage. In conclusion, the LF-IC was selected as a leading system that is expected to improve aerosol delivery efficiency in ventilated infants through the use of small charged particles.
Collapse
Affiliation(s)
- Landon Holbrook
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - P. Worth Longest
- Department of Mechanical Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
15
|
Michotte JB, Jossen E, Roeseler J, Liistro G, Reychler G. In vitro comparison of five nebulizers during noninvasive ventilation: analysis of inhaled and lost doses. J Aerosol Med Pulm Drug Deliv 2015; 27:430-40. [PMID: 24517084 DOI: 10.1089/jamp.2013.1070] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Few studies on performance comparison of nebulizer systems coupled with a single-limb circuit bilevel ventilator are available. Most of these data compared the aerosol drug delivery for only two different systems. Using an adult lung bench model of noninvasive ventilation, we compared inhaled and lost doses of three nebulizer systems coupled with a single-limb circuit bilevel ventilator, as well as the influence of the nebulizer position. METHOD Three vibrating mesh nebulizers (Aeroneb(®) Pro, Aeroneb(®) Solo, and NIVO(®)), one jet nebulizer (Sidestream(®)), and one ultrasonic nebulizer (Servo Ultra Nebulizer 145(®)) coupled with a bilevel ventilator were tested. They were charged with amikacin solution (500 mg/4 mL) and operated at two different positions: before and after the exhalation port (starting from the lung). The inhaled dose, the expiratory wasted dose, and the estimated lost dose were assessed by the residual gravimetric method. RESULTS The doses varied widely among the nebulizer types and position. When the nebulizer was positioned before the exhalation port, the vibrating mesh nebulizer delivered the highest inhaled dose (p<0.001), the jet nebulizer the highest expiratory wasted dose (p<0.001), and the ultrasonic device the highest total lost dose (p<0.001). When the nebulizer was positioned after the exhalation port, the vibrating mesh nebulizers delivered the highest inhaled (p<0.001) and expiratory wasted doses (p<0.001), and the ultrasonic device the highest total lost dose (p<0.001). The most efficient nebulizers were NIVO and Aeroneb Solo when placed before the exhalation port. CONCLUSIONS In a single-limb circuit bilevel ventilator, vibrating mesh nebulizers positioned between the exhalation port and lung model are more efficient for drug delivery compared with jet or ultrasonic nebulizers. In this position, the improved efficiency of vibrating mesh nebulizers was due to an increase in the inhaled dose and a reduction in the exhaled wasted dose compared with placement between the ventilator and the expiratory port. Because of the high total lost dose, the ultrasonic device should not be recommended. Nebulizer placement before the exhalation port increased the inhaled dose and decreased the expiratory wasted dose, except for the jet nebulizer.
Collapse
Affiliation(s)
- Jean-Bernard Michotte
- 1 University of Health Sciences (HESAV), University of Applied Sciences and Arts Western Switzerland (HES-SO) , 1011 Lausanne, Switzerland
| | | | | | | | | |
Collapse
|
16
|
|
17
|
Ari A, de Andrade AD, Sheard M, AlHamad B, Fink JB. Performance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children. J Aerosol Med Pulm Drug Deliv 2014; 28:281-9. [PMID: 25493535 DOI: 10.1089/jamp.2014.1149] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of JN and MN will differ depending on the interface used during aerosol therapy in simulated spontaneously breathing adult and pediatric models. While we expect that aerosol delivery with JN will be less efficient than MN, we also hypothesize that lung deposition obtained with the adult lung model will be more than that with the pediatric lung model in all conditions tested in this study. METHODS A lung model using a teaching manikin connected to a sinusoidal pump via a collecting filter at the level of the bronchi simulating a spontaneously breathing adult (Vt 500 mL, RR 15 bpm, I:E ratio 1:2) or pediatric patient (Vt 150 mL, RR 25 bpm, I:E ratio 1:2). Albuterol sulfate (2.5 mg/3 mL) was aerosolized with JN (Mistymax 10, Airlife) or MN (Aerogen Solo(®), Aerogen) with the Adapter (Aerogen Solo(®) Adapter, Aerogen Ltd, Galway, Ireland) using mouthpiece, aerosol mask, and valved-mask in adults and the dragon mask, aerosol mask, and valved-mask in pediatrics (n=3). The Adapter, specifically designed for MN, was attached to all the interfaces used in this study with supplemental oxygen of 2 lpm, and in addition, the MP was tested with no additional flow in the adult model. The JN was driven with 10 lpm based on the manufacturer's label. Drug was eluted from the filter and analyzed via spectrophotometry. Descriptive statistics, dependent t-test and one-way analysis of variance were used for data analysis. Significant level was set at 0.05. RESULTS In adults, delivery efficiency of JN with the valved mask was significantly greater than that with the aerosol mask (p=0.01). Aerosol delivery of JN with the mouthpiece was not statistically significant from the valved mask (p=0.123) and the aerosol mask (p=0.193). Drug delivery with MN with mouthpiece (15.42±1.4%) and valved-mask (15.15±1.1%) was greater than the open aerosol mask (7.54±0.39%; p=0.0001) in the adult lung model. With no flow mouthpiece delivery increased>2 fold (34.9±3.1%; p=.0001) compared to use of 2 lpm of flow. Using the JN with the pediatric model deposition with valved-mask (5.3±0.8%), dragon mask (4.7±0.9%), and aerosol mask (4.1±0.3%) were similar (p>0.05); while drug delivery with MN via valved-mask (11.1±0.7%) was greater than the dragon mask (6.44±0.3%; p=0.002) and aerosol mask (4.6±0.4%; p=0.002), and the dragon mask was more efficient than the open aerosol mask (p=0.009) CONCLUSION: The type of nebulizer and interface used for aerosol therapy affects delivery efficiency in these simulated spontaneously breathing adult and pediatric models. Drug delivery was greatest with the valved-mouthpiece and mask with JN and MN, while the standard aerosol mask was least efficient in these simulated spontaneously breathing adult and pediatric lung models. Delivery efficiency of JN was less than MN in all conditions tested in this study except in the aerosol mask. Lung deposition obtained with the adult lung model was more than that with the pediatric lung model.
Collapse
Affiliation(s)
- Arzu Ari
- 1 Department of Respiratory Therapy, Georgia State University , Atlanta, Georgia
| | | | - Meryl Sheard
- 1 Department of Respiratory Therapy, Georgia State University , Atlanta, Georgia
| | - Bshayer AlHamad
- 1 Department of Respiratory Therapy, Georgia State University , Atlanta, Georgia
| | - James B Fink
- 1 Department of Respiratory Therapy, Georgia State University , Atlanta, Georgia
| |
Collapse
|
18
|
Longest PW, Azimi M, Hindle M. Optimal delivery of aerosols to infants during mechanical ventilation. J Aerosol Med Pulm Drug Deliv 2014; 27:371-85. [PMID: 24299500 PMCID: PMC4227441 DOI: 10.1089/jamp.2013.1077] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2013] [Accepted: 10/17/2013] [Indexed: 02/06/2023] Open
Abstract
PURPOSE The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS In vitro experiments used a vibrating mesh nebulizer and evaluated drug deposition fraction and emitted dose through ventilation circuits containing either a commercial (CM) or new streamlined (SL) wye connector and 3-mm endotracheal tube (ETT) for aerosols with mass median aerodynamic diameters of 880 nm, 1.78 μm, and 4.9 μm. The aerosol was released into the circuit either over the full inhalation cycle (T1 delivery) or over the first half of inhalation (T2 delivery). Validated computational fluid dynamics (CFD) simulations and whole-lung model predictions were used to assess lung deposition and exhaled dose during cyclic ventilation. RESULTS In vitro experiments at a steady-state tracheal flow rate of 5 L/min resulted in 80-90% transmission of the 880-nm and 1.78-μm aerosols from the ETT. Based on CFD simulations with cyclic ventilation, the SL wye design reduced depositional losses in the wye by a factor of approximately 2-4 and improved lung delivery efficiencies by a factor of approximately 2 compared with the CM device. Delivery of the aerosol over the first half of the inspiratory cycle (T2) reduced exhaled dose from the ventilation circuit by a factor of 4 compared with T1 delivery. Optimal lung deposition was achieved with the SL wye connector and T2 delivery, resulting in 45% and 60% lung deposition for optimal polydisperse (∼1.78 μm) and monodisperse (∼2.5 μm) particle sizes, respectively. CONCLUSIONS Optimization of selected factors and use of a new SL wye connector can substantially increase the lung delivery efficiency of medical aerosols to infants from current values of <1-10% to a range of 45-60%.
Collapse
Affiliation(s)
- P. Worth Longest
- Department of Mechanical and Nuclear Engineering, Virginia Commonwealth University, Richmond, VA
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Mandana Azimi
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| | - Michael Hindle
- Department of Pharmaceutics, Virginia Commonwealth University, Richmond, VA
| |
Collapse
|
19
|
Development of a new technique for the efficient delivery of aerosolized medications to infants on mechanical ventilation. Pharm Res 2014; 32:321-36. [PMID: 25103332 DOI: 10.1007/s11095-014-1466-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Accepted: 07/24/2014] [Indexed: 01/19/2023]
Abstract
PURPOSE To evaluate the efficiency of a new technique for delivering aerosols to intubated infants that employs a new Y-connector, access port administration of a dry powder, and excipient enhanced growth (EEG) formulation particles that change size in the airways. METHODS A previously developed CFD model combined with algebraic correlations were used to predict delivery system and lung deposition of typical nebulized droplets (MMAD = 4.9 μm) and EEG dry powder aerosols. The delivery system consisted of a Y-connector [commercial (CM); streamlined (SL); or streamlined with access port (SL-port)] attached to a 4-mm diameter endotracheal tube leading to the airways of a 6-month-old infant. RESULTS Compared to the CM device and nebulized aerosol, the EEG approach with an initial 0.9 μm aerosol combined with the SL and SL-port geometries reduced device depositional losses by factors of 3-fold and >10-fold, respectively. With EEG powder aerosols, the SL geometry provided the maximum tracheobronchial deposition fraction (55.7%), whereas the SL-port geometry provided the maximum alveolar (67.6%) and total lung (95.7%) deposition fractions, respectively. CONCLUSIONS Provided the aerosol can be administered in the first portion of the inspiration cycle, the proposed new method can significantly improve the deposition of pharmaceutical aerosols in the lungs of intubated infants.
Collapse
|
20
|
Kamin W, Erdnüss F, Krämer I. Inhalation solutions — Which ones may be mixed? Physico-chemical compatibility of drug solutions in nebulizers — Update 2013. J Cyst Fibros 2014; 13:243-50. [DOI: 10.1016/j.jcf.2013.09.006] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2013] [Revised: 09/16/2013] [Accepted: 09/20/2013] [Indexed: 12/13/2022]
|