1
|
Liu S, Zhang Y, Liu W, Yin T, Yuan J, Ran J, Li X. Simultaneous multi-slice technique for reducing acquisition times in diffusion tensor imaging of the knee: a feasibility study. Skeletal Radiol 2024:10.1007/s00256-024-04719-y. [PMID: 38913177 DOI: 10.1007/s00256-024-04719-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Revised: 05/30/2024] [Accepted: 05/30/2024] [Indexed: 06/25/2024]
Abstract
OBJECTIVES To explore the feasibility of simultaneous multi-slice (SMS) technique for reducing acquisition times in readout-segmented echo planar imaging (RESOLVE) for diffusion tensor imaging (DTI) of the knee. MATERIALS AND METHODS A total of 30 healthy volunteers and 23 patients with knee acute injury (12 cases with anterior ligament (ACL) tears and 16 cases with patellar cartilage (PC) injury) were enrolled in this prospective study. Three DTI protocols were used: conventional RESOLVE-DTI with 12 directions (protocol 1), SMS-RESOLVE-DTI with 12 directions (protocol 2) and 20 directions (protocol 3). DTI parameters of gastrocnemius, ACL and posterior cruciate ligament (PCL), and PC from three protocols were quantitatively assessed. RESULTS For volunteers, protocol 2 significantly reduced acquisition time by 38.6% and 34.2% compared to protocols 1 and 3 while maintaining similar high-quality images and similar diffusive parameters, except for the fractional anisotropy (FA) and axial diffusivity (AD) of the PC between protocols 2 and 1 (P < 0.05). For injured ACL and PC, protocols 1 and 2 showed similar accurate diffusive parameters (except for AD, P = 0.025) and similar diagnostic efficacy, which demonstrated significantly lower FA and higher radial diffusivity (RD) in protocols 1 and 2 compared to volunteers (P < 0.05). CONCLUSIONS The 12-direction SMS-RESOLVE-DTI demonstrated a favorable balance between acquisition time and image quality, making it a promising alternative to conventional DTI for evaluating ligament and cartilage injuries. ADVANCES IN KNOWLEDGE The SMS technique greatly reduces acquisition time while maintaining image quality, which signified the possibility of DTI's clinical application.
Collapse
Affiliation(s)
- Simin Liu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China
| | - Yao Zhang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China
| | - Wei Liu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., No. 32 Gaoxin C. Ave., 2nd, Shenzhen, China
| | - Ting Yin
- MR Collaborations, Siemens Healthineers Ltd., Chengdu, China
| | - Jie Yuan
- Department of Radiology, Zhongxiang People's Hospital, Zhongxiang City, China
| | - Jun Ran
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China.
| | - Xiaoming Li
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, No.1095, Jiefang Road, Wuhan, Hubei Province, China.
| |
Collapse
|
2
|
Zhang Y, Ye Z, Xia C, Tan Y, Zhang M, Lv X, Tang J, Li Z. Clinical Applications and Recent Updates of Simultaneous Multi-slice Technique in Accelerated MRI. Acad Radiol 2024; 31:1976-1988. [PMID: 38220568 DOI: 10.1016/j.acra.2023.12.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Revised: 12/15/2023] [Accepted: 12/19/2023] [Indexed: 01/16/2024]
Abstract
Simultaneous multi-slice (SMS) is a magnetic resonance imaging (MRI) acceleration technique that utilizes multi-band radio-frequency pulses to simultaneously excite and encode multiple slices. Currently, SMS has been widely studied and applied in the MRI examination to reduce acquisition time, which can significantly improve the examination efficiency and patient throughput. Moreover, SMS technique can improve spatial resolution, which is of great value in disease diagnosis, treatment response monitoring, and prognosis prediction. This review will briefly introduce the technical principles of SMS, and summarize its current clinical applications. More importantly, we will discuss the recent technical progress and future research direction of SMS, hoping to highlight the clinical value and scientific potential of this technique.
Collapse
Affiliation(s)
- Yiteng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zheng Ye
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Chunchao Xia
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Yuqi Tan
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Meng Zhang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Xinyang Lv
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Jing Tang
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital of Sichuan University, No. 37 Guoxue Alley, Chengdu, 610041, Sichuan, China.
| |
Collapse
|
3
|
Ye Z, Yao S, Yang T, Li Q, Li Z, Song B. Abdominal Diffusion-Weighted MRI With Simultaneous Multi-Slice Acquisition: Agreement and Reproducibility of Apparent Diffusion Coefficients Measurements. J Magn Reson Imaging 2024; 59:1170-1178. [PMID: 37334872 DOI: 10.1002/jmri.28876] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2022] [Revised: 06/07/2023] [Accepted: 06/07/2023] [Indexed: 06/21/2023] Open
Abstract
BACKGROUND Simultaneous multi-slice diffusion-weighted imaging (SMS-DWI) can shorten acquisition time in abdominal imaging. PURPOSE To investigate the agreement and reproducibility of apparent diffusion coefficient (ADC) from abdominal SMS-DWI acquired with different vendors and different breathing schemes. STUDY TYPE Prospective. SUBJECTS Twenty volunteers and 10 patients. FIELD STRENGTH/SEQUENCE 3.0 T, SMS-DWI with a diffusion-weighted echo-planar imaging sequence. ASSESSMENT SMS-DWI was acquired using breath-hold and free-breathing techniques in scanners from two vendors, yielding four scans in each participant. Average ADC values were measured in the liver, pancreas, spleen, and both kidneys. Non-normalized ADC and ADCs normalized to the spleen were compared between vendors and breathing schemes. STATISTICAL TESTS Paired t-test or Wilcoxon signed rank test; intraclass correlation coefficient (ICC); Bland-Altman method; coefficient of variation (CV) analysis; significance level: P < 0.05. RESULTS Non-normalized ADCs from the four SMS-DWI scans did not differ significantly in the spleen (P = 0.262, 0.330, 0.166, 0.122), right kidney (P = 0.167, 0.538, 0.957, 0.086), and left kidney (P = 0.182, 0.281, 0.504, 0.405), but there were significant differences in the liver and pancreas. For normalized ADCs, there were no significant differences in the liver (P = 0.315, 0.915, 0.198, 0.799), spleen (P = 0.815, 0.689, 0.347, 0.423), pancreas (P = 0.165, 0.336, 0.304, 0.584), right kidney (P = 0.165, 0.336, 0.304, 0.584), and left kidney (P = 0.496, 0.304, 0.443, 0.371). Inter-reader agreements of non-normalized ADCs were good to excellent (ICCs ranged from 0.861 to 0.983), and agreement and reproducibility were good to excellent depending on anatomic location (CVs ranged from 3.55% to 13.98%). Overall CVs for abdominal ADCs from the four scans were 6.25%, 7.62%, 7.08, and 7.60%. DATA CONCLUSION The normalized ADCs from abdominal SMS-DWI may be comparable between different vendors and breathing schemes, showing good agreement and reproducibility. ADC changes above approximately 8% may potentially be considered as a reliable quantitative biomarker to assess disease or treatment-related changes. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Shan Yao
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ting Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Li
- MR Collaborations, Siemens Healthineers, Shanghai, China
| | - Zhenlin Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
- Department of Radiology, Sanya People's Hospital, Sanya, China
| |
Collapse
|
4
|
Stabinska J, Wittsack HJ, Lerman LO, Ljimani A, Sigmund EE. Probing Renal Microstructure and Function with Advanced Diffusion MRI: Concepts, Applications, Challenges, and Future Directions. J Magn Reson Imaging 2023:10.1002/jmri.29127. [PMID: 37991093 PMCID: PMC11117411 DOI: 10.1002/jmri.29127] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 11/23/2023] Open
Abstract
Diffusion measurements in the kidney are affected not only by renal microstructure but also by physiological processes (i.e., glomerular filtration, water reabsorption, and urine formation). Because of the superposition of passive tissue diffusion, blood perfusion, and tubular pre-urine flow, the limitations of the monoexponential apparent diffusion coefficient (ADC) model in assessing pathophysiological changes in renal tissue are becoming apparent and motivate the development of more advanced diffusion-weighted imaging (DWI) variants. These approaches take advantage of the fact that the length scale probed in DWI measurements can be adjusted by experimental parameters, including diffusion-weighting, diffusion gradient directions and diffusion time. This forms the basis by which advanced DWI models can be used to capture not only passive diffusion effects, but also microcirculation, compartmentalization, tissue anisotropy. In this review, we provide a comprehensive overview of the recent advancements in the field of renal DWI. Following a short introduction on renal structure and physiology, we present the key methodological approaches for the acquisition and analysis of renal DWI data, including intravoxel incoherent motion (IVIM), diffusion tensor imaging (DTI), non-Gaussian diffusion, and hybrid IVIM-DTI. We then briefly summarize the applications of these methods in chronic kidney disease and renal allograft dysfunction. Finally, we discuss the challenges and potential avenues for further development of renal DWI. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Hans-Jörg Wittsack
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Lilach O. Lerman
- Division of Nephrology and Hypertension and Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA
| | - Alexandra Ljimani
- Department of Diagnostic and Interventional Radiology, Medical Faculty, Heinrich Heine University Düsseldorf, Dusseldorf, Germany
| | - Eric E. Sigmund
- Bernard and Irene Schwartz Center for Biomedical Imaging Center for Advanced Imaging Innovation and Research (CAI2R), New York University Langone Health, New York City, New York, USA
| |
Collapse
|
5
|
Huang H, Zhou M, Gong T, Wang Y. Feasibility of high-resolution readout-segmented echo-planar imaging with simultaneous multislice imaging in assessing rectal cancer. Abdom Radiol (NY) 2023; 48:2258-2269. [PMID: 37142823 DOI: 10.1007/s00261-023-03937-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2023] [Revised: 04/19/2023] [Accepted: 04/20/2023] [Indexed: 05/06/2023]
Abstract
PURPOSE To investigate the feasibility of high-resolution readout-segmented echo-planar imaging (rs-EPI) with simultaneous multislice (SMS) imaging to predict well-differentiated rectal cancer.Kindly check and confirm whether the Author Name 'Hongyun Huang ' is correctly identified.confirm METHODS: A total of eighty-three patients with nonmucinous rectal adenocarcinoma received both prototype SMS high-spatial-resolution and conventional rs-EPI sequences. Image quality was subjectively assessed by two experienced radiologists using a 4-point Likert scale (1 = poor, 4 = excellent). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) and apparent diffusion coefficient (ADC) of the lesion were measured by two experienced radiologists in the objective assessment. Paired t tests or Mann‒Whitney U tests were used to compare the two groups. The areas under the receiver operating characteristic (ROC) curves (AUCs) were used to determine the predictive value of the ADCs in discriminating well-differentiated rectal cancer in the two groups. A two-sided p value < 0.05 represented statistical significance.Please check and confirm if the authors and affiliation details have been correctly identified. Amend if necessary.confirm RESULTS: In the subjective assessment, high-resolution rs-EPI had better image quality than conventional rs-EPI (p < 0.001). High-resolution rs-EPI also had a significantly higher SNR and CNR (p < 0.001). The T stage of rectal cancer was inversely correlated with the ADCs measured on high-resolution rs-EPI (r = -0.622, p < 0.001) and rs-EPI (r = -0.567, p < 0.001). The AUC of high-resolution rs-EPI in predicting well-differentiated rectal cancer was 0.768. CONCLUSION High-resolution rs-EPI with SMS imaging provided significantly higher image quality, SNRs, and CNRs and more stable ADC measurements than conventional rs-EPI. Additionally, the pretreatment ADC on high-resolution rs-EPI could discriminate well-differentiated rectal cancer.
Collapse
Affiliation(s)
- Hongyun Huang
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 32, West Second Section of First Ring Road, Qingyang District, Chengdu, 610072, People's Republic of China
| | - Mi Zhou
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 32, West Second Section of First Ring Road, Qingyang District, Chengdu, 610072, People's Republic of China
| | - Tong Gong
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 32, West Second Section of First Ring Road, Qingyang District, Chengdu, 610072, People's Republic of China
| | - Yuting Wang
- Department of Radiology, Sichuan Provincial People's Hospital, University of Electronic Science and Technology of China, No. 32, West Second Section of First Ring Road, Qingyang District, Chengdu, 610072, People's Republic of China.
| |
Collapse
|
6
|
Yang T, Li Y, Ye Z, Yao S, Li Q, Yuan Y, Song B. Diffusion Weighted Imaging of the Abdomen and Pelvis: Recent Technical Advances and Clinical Applications. Acad Radiol 2023; 30:470-482. [PMID: 36038417 DOI: 10.1016/j.acra.2022.07.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/20/2022] [Accepted: 07/23/2022] [Indexed: 01/25/2023]
Abstract
Diffusion weighted imaging (DWI) serves as one of the most important functional magnetic resonance imaging techniques in abdominal and pelvic imaging. It is designed to reflect the diffusion of water molecules and is particularly sensitive to the malignancies. Yet, the limitations of image distortion and artifacts in single-shot DWI may hamper its widespread use in clinical practice. With recent technical advances in DWI, such as simultaneous multi-slice excitation, computed or reduced field-of-view techniques, as well as advanced shimming methods, it is possible to achieve shorter acquisition time, better image quality, and higher robustness in abdominopelvic DWI. This review discussed the recent advances of each DWI approach, and highlighted its future perspectives in abdominal and pelvic imaging, hoping to familiarize physicians and radiologists with the technical improvements in this field and provide future research directions.
Collapse
Affiliation(s)
- Ting Yang
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Ying Li
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Zheng Ye
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Shan Yao
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Qing Li
- MR Collaborations, Siemens Healthcare, Shanghai, China
| | - Yuan Yuan
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu, China; Department of Radiology, Sanya People's Hospital, Sanya, Hainan, China.
| |
Collapse
|
7
|
Effectiveness of simultaneous multislice accelerated readout-segmented echo planar imaging for the assessment of rectal cancer. Eur J Radiol 2023; 159:110649. [PMID: 36563564 DOI: 10.1016/j.ejrad.2022.110649] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 11/17/2022] [Accepted: 12/10/2022] [Indexed: 12/15/2022]
Abstract
PURPOSE To investigate the effectiveness of simultaneous multislice (SMS) accelerated readout-segmented echo planar imaging (RESOLVE) DWI for assessing rectal cancer in the clinic. METHOD Sixty consecutive histologically proven rectal cancer patients were enrolled. They all received MRI examinations, including both SMS-RESOLVE and RESOLVE sequences. Two readers visually assessed the overall image quality, distinction of anatomical structures, lesion conspicuity, and artifacts of two sequences by using a qualitative 4-point Likert scale. The quantitative ADC value, lesion contrast, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and temporal SNR (tSNR) were independently calculated in rectal cancer on the largest slice of the tumor. RESULTS The scan time was shortened from 3 min and 50 s to 1 min and 47 s. The interobserver agreement of visual and quantitative assessments between the two readers was good overall. There were no differences in overall image quality, lesion conspicuity or artifact scores between the two sequences in both readers (all p > 0.05). The lesion contrast (p = 0.013) was significantly higher in SMS-RESOLVE, and the CNR was similar in the two DWIs. The scores of distinctions of anatomical structures in SMS-RESOLVE were lower (all p < 0.05) in both readers. The SNR of SMS-RESOLVE was lower than that of RESOLVE (p = 0.004), and the tSNR of SMS-RESOLVE was significantly higher (p < 0.001). The ADC value of the tumor was lower in SMS-RESOLVE (p = 0.001), but the ADC values of the normal rectal wall showed no difference between the two DWIs. CONCLUSION SMS-RESOLVE allowed a substantial reduction in acquisition time while maintaining overall image quality and lesion conspicuity in rectal cancer. It also had a higher contrast of the lesion and a higher temporal SNR.
Collapse
|
8
|
Feasibility of Simultaneous Multislice Acceleration Technique in Readout-Segmented Echo-Planar Diffusion-Weighted Imaging for Assessing Rectal Cancer. Diagnostics (Basel) 2023; 13:diagnostics13030474. [PMID: 36766579 PMCID: PMC9914524 DOI: 10.3390/diagnostics13030474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 01/02/2023] [Accepted: 01/04/2023] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Readout-segmented echo-planar imaging (rs-EPI) with simultaneous multislice (SMS) technology has been successfully applied to tumor research in many organs, but no feasibility study in rectal cancer has been reported, and the optimal acceleration of SMS with rs-EPI in rectal cancer has not been well determined yet. OBJECTIVE To investigate the feasibility of SMS rs-EPI of rectal cancer with different acceleration factors (AFs) and its influence on image quality, acquisition time and apparent diffusion coefficients (ADCs) in comparison to conventional sequences. METHODS All patients underwent rs-EPI and SMS rs-EPI with AFs of 2 and 3 (2 × SMS rs-EPI and 3 × SMS rs-EPI, respectively) using a 3T scanner. Acquisition times of the three rs-EPI sequences were measured. Image qualitative parameters (5-point Likert scale), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), geometric distortion, and apparent diffusion coefficient (ADC) values of the three sequences were compared. RESULTS A total of eighty-three patients were enrolled in our study. rs-EPI and 2 × SMS rs-EPI offered equivalently high overall image quality with a scan time reduction to nearly half (rs-EPI: 137 s, 2 × SM rs-EPI: 60 s). 3 × SMS rs-EPI showed significantly poorer image quality (p < 0.05). ADC values were significantly lower in 3 × SMS rs-EPI compared to rs-EPI in rectal tumors and normal tissue (tumor tissue: rs-EPI 1.19 ± 0.21 × 10-3 mm2/s, 3 × SMS rs-EPI 1.10 ± 0.26 × 10-3 mm2/s, p < 0.001; normal tissue: rs-EPI 1.68 ± 0.13 × 10-3 mm2/s, 3 × SMS rs-EPI 1.54 ± 0.20 × 10-3 mm2/s, p < 0.001). CONCLUSIONS SMS rs-EPI using an AF of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of rs-EPI when the slice distance and number of shots are the same among three rs-EPI sequences.
Collapse
|
9
|
Culleton S, Hashemizadeh Kolowori SK, Roberts J, de Havenon A, DiBella E, McNally JS. A comparison of simultaneous multislice and conventional diffusion tensor imaging techniques for ischemic stroke evaluation at 1.5T. Br J Radiol 2023; 96:20220222. [PMID: 36469531 PMCID: PMC10997011 DOI: 10.1259/bjr.20220222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 09/02/2022] [Accepted: 10/05/2022] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVE Diffusion tensor imaging (DTI) is a promising technique for ischemic stroke evaluation; however, acquisition time is longer than DWI. Simultaneous multislice (SMS) imaging acquires multiple slices together and reduces scan time. This study compared conventional and SMS DTI for ischemic stroke workup. METHODS Following IRB approval, the departmental stroke protocol was supplemented with SMS DTI on a clinical 1.5T MRI. Cases suspicious for ischemic stroke outside the treatment window were included. Standard DTI (STD-DTI, 20-direction, b = 2000 s/mm2), was followed by SMS-2-DTI (two slices simultaneously imaged). Two blinded neuroradiologists independently assessed image quality and DTI-trace status (positive/negative = stroke/other). Average image quality, interrater reliability (κ), receiver operating characteristic area under the curve (AUC), signal-to-noise ratio (SNR = DTI-source min/max/average), coefficient of variation (CV), mean diffusivity (MD), and fractional anisotropy (FA, of DTI-trace) were compared using two-tailed t-tests and a p < .05. RESULTS 41 patients were evaluated. SMS-2-DTI decreased DTI time by 132.17 ± 15.33 s, a 45% reduction. SMS-2-DTI reduced image quality (STD-DTI 4.7 ± 0.5 vs SMS-2-DTI 3.8 ± 0.6, p < .001). Diagnostic accuracy persisted, AUC was high for observer 1 (STD-DTI 0.95, 95%CI = 0.88-1.00 vs SMS-2-DTI 0.94, 95%CI = 0.87-1.00, p = .86) and observer 2 (STD-DTI 0.89, 95%CI = 0.79-0.99 vs SMS-2-DTI 0.86, 95%CI = 0.76-0.97, p = .66). Interrater reliability was high for STD-DTI (κ = 0.80, 95%CI = 0.61-0.98) and SMS-2-DTI (κ = 0.84, 95%CI = 0.67-1.00). SMS-2-DTI significantly decreased average SNR (STD-DTI 42.85 ± 4.44 vs SMS-2-DTI 32.58 ± 4.30, p < .001), and CV MD (STD-DTI 0.23 ± 0.03 vs 0.20 ± 0.04, p < .001). CV FA and CV DTI-trace were not statistically different. CONCLUSIONS This study supports using SMS to accelerate DTI for ischemic stroke workup at 1.5T in the non-hyper-acute setting. ADVANCES IN KNOWLEDGE This study highlights the feasibility of accelerated multislice DTI for faster diagnostic DTI-trace images capable of ischemic stroke detection.
Collapse
Affiliation(s)
- Sinéad Culleton
- Utah Center for Advanced Imaging Research, Department of
Radiology, University of Utah, Salt Lake City, Utah,
United States
| | | | - John Roberts
- Utah Center for Advanced Imaging Research, Department of
Radiology, University of Utah, Salt Lake City, Utah,
United States
| | - Adam de Havenon
- Department of Neurology, Yale University, New
Haven, Connecticut, United States
| | - Edward DiBella
- Utah Center for Advanced Imaging Research, Department of
Radiology, University of Utah, Salt Lake City, Utah,
United States
| | - J Scott McNally
- Utah Center for Advanced Imaging Research, Department of
Radiology, University of Utah, Salt Lake City, Utah,
United States
| |
Collapse
|
10
|
Koëter T, Jongen G, Hanrath-Vos E, Smit E, Fütterer J, Maas M, Scheenen T. Reducing Acquisition Time of Diffusion Weighted MR Imaging of the Rectum with Simultaneous Multi-Slice Acquisition: A Reader Study. Acad Radiol 2022; 29:1802-1807. [PMID: 35256274 DOI: 10.1016/j.acra.2022.02.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 02/03/2022] [Accepted: 02/05/2022] [Indexed: 01/26/2023]
Abstract
RATIONALE AND OBJECTIVES To assess the acquisition time and image quality of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) versus conventional DWI (C-DWI) of the rectum. MATERIALS AND METHODS In patients scheduled for a magnetic resonance imaging of the rectum, both SMS-DWI and C-DWI were performed on a 3T whole body magnetic resonance scanner. Image quality of the DWI sequences was reviewed by two independent radiologists who were blinded to the method of imaging using a five-point Likert scale: (score ranging from 1 (non-diagnostic) to 5 (excellent). The mean scores of SMS-DWI versus C-DWI were compared for the individual readers using a nonparametric test (Wilcoxon signed ranks). RESULTS The SMS-DWI protocol acquisition time was 4:08 min vs. 7:24 min per patient, which led to a reduction of 44.1% for the C-DWI protocol, both excluding time for sequence specific adjustments (shimming). No statistical differences between the conventional-, and SMS- diffusion weighted images were seen for both readers. Mean overall image quality of the SMS-DWI TRACE images was 3.5 (SD: 1.3) and 3.3 (SD: 1.0) for reader 1 and reader 2, respectively. Mean overall image quality of the C-DWI TRACE images was 3.4 (SD: 1.3) and 3.2 (SD: 1.1) for reader 1 and reader 2, respectively. CONCLUSION Optimized SMS-DWI compared to C-DWI in imaging of the rectum showed similar image quality while a significant acquisition time reduction was achieved.
Collapse
Affiliation(s)
- Tijmen Koëter
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands; Department of Surgery, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands.
| | - Germaine Jongen
- Department of Radiation Oncology, Radboud University Medical Center, Nijmegen, The Netherlands
| | - Eline Hanrath-Vos
- Department of Radiology, Elisabeth-TweeSteden Ziekenhuis (ETZ), Tilburg, The Netherlands
| | - Ewoud Smit
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands
| | - Jurgen Fütterer
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands
| | - Marnix Maas
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands
| | - Tom Scheenen
- Department of Medical Imaging, Radboud University Medical Center, Geert Grooteplein Zuid 10, Nijmegen, The Netherlands
| |
Collapse
|
11
|
Whole-tumor apparent diffusion coefficient (ADC) analyses of breast lesions based on simultaneous multi-slice readout-segmented echo-planar diffusion-weighted imaging. Magn Reson Imaging 2022; 94:119-126. [PMID: 36191856 DOI: 10.1016/j.mri.2022.09.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/28/2022] [Accepted: 09/27/2022] [Indexed: 11/24/2022]
Abstract
OBJECTIVE We aimed to evaluate the effectiveness of simultaneous multi-slice readout-segmented echo-planar diffusion-weighted imaging (SMS rs-EPI DWI), compared with readout-segmented echo-planar diffusion-weighted imaging (NOSMS rs-EPI DWI), in discriminating between benign and malignant breast lesions. MATERIALS AND METHODS This retrospective study evaluated breast lesions from 185 consecutive patients who had undergone preoperative breast MRI. The NOSMS rs-EPI DWI and the prototype SMS rs-EPI DWI sequences were performed on a 1.5-T MR scanner. Two independent radiologists evaluated the image quality of the two sequences using a 5-point scale (1 = poor, 5 = excellent) and then assessed the scores through visual grading characteristics analysis (VGC). The values of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and whole-tumor-based histogram parameter (ADCmedian) were compared between the two sequences using the Wilcoxon test. Then ROC curves were used for statistical analysis. RESULTS The visual assessment showed that the SMS rs-EPI yielded superior overall image quality and lesion delineation than the NOSMS rs-EPI (AUCVGC = 0.980 and 0.984, respectively; all Ps < 0.001). There were no significant differences in relevant artifacts between the two sequences (AUCVGC = 0.531, P = 0.462). The SNR values for SMS rs-EPI DWI were significantly lower than for NOSMS rs-EPI DWI (P = 0.019) while there was no significant difference in CNR values between the two sequences (P = 0.955). In addition, evaluation of the diagnostic performance demonstrated that the difference in ADCmedian values for both DWI sequences between the malignant and benign lesions was statistically significant (P < 0.001). In contrast, the AUC for ADCmedian was higher with SMS rs-EPI than NOSMS rs-EPI (0.879 for SMS vs. 0.839 for NOSMS, P = 0.025). CONCLUSION The SMS technique could further improve the image quality and the diagnostic performance of rs-EPI DWI in a comparable time.
Collapse
|
12
|
Hausmann D, Pindur A, Todorski I, Weiland E, Kuehn B, Zhou K, Bosshard L, Prummer M, Kubik-Huch RA. Quantitative assessment of iteratively denoised 3D SPACE with inner-volume excitation and simultaneous multi-slice BLADE for optimizing female pelvis magnetic resonance imaging at 1.5 T. Acad Radiol 2022; 30:1129-1140. [PMID: 35871059 DOI: 10.1016/j.acra.2022.06.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 11/01/2022]
Abstract
RATIONALE AND OBJECTIVES High-resolution T2-weighted magnetic resonance imaging (MRI) of the pelvis is the main technique used for diagnosing benign and malignant uterine diseases. However, the procedure may be time-consuming and requires training and experience. Therefore, this study was performed to compare the image quality of standard clinical BLADE (stBLADE) with a prototypical accelerated simultaneous multi-slice (SMS) BLADE procedure with either improved temporal resolution (tr) at the same slice thickness (SL) or improved spatial resolution (sr) with the same examination time and a prototypical isotropic 3D SPACE procedure with inner-volume excitation and iterative denoising. MATERIALS AND METHODS Patients who underwent clinically indicated MRI of the uterus were included in this prospective study and underwent stBLADE (acquisition time, 2 min 59 s; SL, 4 mm) and SMS BLADE (tr) with the same SL (4 mm) but reduced examination time (1 min 20 s) as well as SMS BLADE (sr) with thinner slices (3 mm) and comparable examination time (3 min 16 s). In addition, 3D SPACE was acquired in a sagittal orientation (5 min 36 s). The short axis of the cervix and the long axis of the corpus uteri were reconstructed in 1-mm and 3-mm SLs, retrospectively. Subjective overall image impression, delineation of anatomy/organs, lesion demarcation, and motion artifacts were assessed using a 5-point Likert scale and compared among the different techniques. The preferred sequence was then selected by three independent assessors. RESULTS The analysis was based on 38 women (mean age, 44 ± 15 years). The overall image impression was similar for stBLADE, SMS BLADE (sr), and SMS BLADE (tr) but was significantly lower for 3D SPACE than stBLADE (p = 0.01). SMS BLADE (sr) was considered the preferred sequence because of slightly better performance in terms of overall image impression, organ delineation, and lesion demarcation, but without statistical significance. Both SMS BLADE (tr) and (sr) produced significantly fewer motion artifacts than stBLADE (p < 0.01 and p = 0.01), with no significant difference between SMS BLADE (tr) and (sr), while 3D SPACE had a significantly lower rating than stBLADE (p < 0.01). Image quality was rated as the least diagnostic criterion in all sequences and all cases. CONCLUSION SMS BLADE (sr) was the preferred sequence for MRI of the female pelvis, with higher sr than stBLADE. SMS BLADE (tr) may also be used to reduce the acquisition time without compromising image quality. Despite its lower image quality, 3D SPACE can also reduce the examination time and improve the workflow because of the possibility of retrospective multiplanar reconstructions.
Collapse
Affiliation(s)
- Daniel Hausmann
- Department of Radiology, Institute of Radiology, Kantonsspital Baden, Im Ergel 1, Baden 5404, Switzerland; Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
| | - Alexandra Pindur
- Department of Radiology, Institute of Radiology, Kantonsspital Baden, Im Ergel 1, Baden 5404, Switzerland
| | - Inga Todorski
- Department of Radiology, Institute of Radiology, Kantonsspital Baden, Im Ergel 1, Baden 5404, Switzerland
| | - Elisabeth Weiland
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Bernd Kuehn
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Khun Zhou
- Digital Department, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Lars Bosshard
- Nexus Personalized Health Technologies, ETH Zurich, and Swiss Institute for Bioinformatics (SIB), Zurich, Switzerland
| | - Michael Prummer
- Nexus Personalized Health Technologies, ETH Zurich, and Swiss Institute for Bioinformatics (SIB), Zurich, Switzerland
| | - Rahel A Kubik-Huch
- Department of Radiology, Institute of Radiology, Kantonsspital Baden, Im Ergel 1, Baden 5404, Switzerland
| |
Collapse
|
13
|
Tang C, Qin Y, Hu Q, Ai T. Diagnostic value of multi-model high-resolution diffusion-weighted MR imaging in breast lesions: Based on simultaneous multi-slice readout-segmented echo-planar imaging. Eur J Radiol 2022; 154:110439. [PMID: 35863281 DOI: 10.1016/j.ejrad.2022.110439] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 06/30/2022] [Accepted: 07/05/2022] [Indexed: 11/19/2022]
Abstract
PURPOSE To investigate the diagnostic value of multi-model high-resolution diffusion-weighted MR imaging (DWI) in breast lesions, with a comparison of simultaneous multi-slice readout-segmented echo-planar imaging (SMS rs-EPI) and single-shot EPI (ss-EPI). MATERIALS AND METHODS This retrospective study was approved by the institutional ethics committee and included 120 patients with 122 breast lesions (25 benign and 97 malignant). All patients underwent breast DWI with multi-b values (0, 50, 100, 200, 400, 800, 1200, and 2000 s/mm2) based on both SMS rs-EPI and ss-EPI on a 3.0 T MR scanner. Quantitative DWI-derived parameters including ADC, MK, MD, D, D*, and f were calculated based on mono-exponential (Mono), intravoxel incoherent motion (IVIM), diffusion kurtosis (DKI) models. Meanwhile, both DWI sequences were qualitatively evaluated with respect to overall image quality, lesion conspicuity, image artifact, geometric distortion, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and lesion contrast. The differences in DW-derived parameters, image quality, and diagnostic performance were statistically compared between SMS rs-EPI and ss-EPI groups. RESULTS The SMS rs-EPI produced higher Contrast, CNR and lower SNR than ss-EPI (p < 0.01). The image quality of SMS rs-EPI was superior to ss-EPI either in subjective or objective evaluation. There was no significant difference between the SMS rs-EPI and ss-EPI for either MD or the D* (p > 0.05). However, the MK and f between the two sequences showed significant differences (p < 0.05). Spearman's correlation coefficient displayed good linear correlation for MK values (r = 0.73, 95% CI 0.617-0.857), MD values (r = 0.88, 95% CI 0.814-0.926), ADC values (r = 0.93, 95% CI 0.869-0.948) and D values (r = 0.93, 95% CI 0.856-0.948) between SMS rs-EPI and ss-EPI. Spearman's correlation coefficient for f values (r = 0.25, 95% CI 0.226-0.559) and D* values (r = 0.22, 95% CI 0.025-0.348) were fair and no correlation between the two sequences. MK values have the highest diagnostic value in differentiating benign and malignant breast lesions. CONCLUSIONS High-resolution multi-model DWI based on SMS rs-EPI technique can provide superior image quality and lesion characterization, with comparable diagnostic performance as compared with ss-EPI DWI in differentiating benign and malignant breast lesions. Of different DWI-derived parameters, MK values showed the best diagnostic performance.
Collapse
Affiliation(s)
- Caili Tang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yanjin Qin
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Qilan Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
| |
Collapse
|
14
|
Starekova J, Zhao R, Colgan TJ, Johnson KM, Rehm JL, Wells SA, Reeder SB, Hernando D. Improved free-breathing liver fat and iron quantification using a 2D chemical shift–encoded MRI with flip angle modulation and motion-corrected averaging. Eur Radiol 2022; 32:5458-5467. [DOI: 10.1007/s00330-022-08682-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Revised: 01/07/2022] [Accepted: 02/17/2022] [Indexed: 11/29/2022]
|
15
|
Vasylechko SD, Warfield SK, Afacan O, Kurugol S. Self-supervised IVIM DWI parameter estimation with a physics based forward model. Magn Reson Med 2022; 87:904-914. [PMID: 34687065 PMCID: PMC8627432 DOI: 10.1002/mrm.28989] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 07/29/2021] [Accepted: 08/08/2021] [Indexed: 02/03/2023]
Abstract
PURPOSE To assess the robustness and repeatability of intravoxel incoherent motion model (IVIM) parameter estimation for the diffusion-weighted MRI in the abdominal organs under the constraints of noisy diffusion signal using a novel neural network method. METHODS Clinically acquired abdominal scans of Crohn's disease patients were retrospectively analyzed with regions segmented in the kidney cortex, spleen, liver, and bowel. A novel IVIM parameter fitting method based on the principle of a physics guided self-supervised convolutional neural network that does not require reference parameter estimates for training was compared to a conventional non-linear least squares (NNLS) algorithm, and a voxelwise trained artificial neural network (ANN). RESULTS Results showed substantial increase in parameter robustness to the noise corrupted signal. In an intra-session repeatability experiment, the proposed method showed reduced coefficient of variation (CoV) over multiple acquisitions in comparison to conventional NLLS method and comparable performance to ANN. The use of D and f estimates from the proposed method led to the smallest misclassification error in linear discriminant analysis for characterization between normal and abnormal Crohn's disease bowel tissue. The fitting of D∗ parameter remains to be challenging. CONCLUSION The proposed method yields robust estimates of D and f IVIM parameters under the constraints of noisy diffusion signal. This indicates a potential for the use of the proposed method in conjunction with accelerated DW-MRI acquisition strategies, which would typically result in lower signal to noise ratio.
Collapse
Affiliation(s)
- Serge Didenko Vasylechko
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
- Corresponding author: Name Serge Didenko Vasylechko, Department Computational Radiology Laboratory, Institute Boston Children’s Hospital, Address 360 Longwood Avenue, Boston, MA, 02215, USA,
| | - Simon K. Warfield
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Onur Afacan
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| | - Sila Kurugol
- Computational Radiology Laboratory, Boston Children’s Hospital, Boston, MA, USA
- Harvard Medical School, Boston, MA, USA
| |
Collapse
|
16
|
Glutig K, Krüger PC, Oberreuther T, Nickel MD, Teichgräber U, Lorenz M, Mentzel HJ, Krämer M. Preliminary results of abdominal simultaneous multi-slice accelerated diffusion-weighted imaging with motion-correction in patients with cystic fibrosis and impaired compliance. Abdom Radiol (NY) 2022; 47:2783-2794. [PMID: 35596778 PMCID: PMC9300552 DOI: 10.1007/s00261-022-03549-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2022] [Revised: 04/27/2022] [Accepted: 04/28/2022] [Indexed: 01/18/2023]
Abstract
OBJECTIVES The aim of this prospective study was to compare scan time, image quality, signal-to-noise Ratio (SNR), and apparent diffusion coefficient (ADC) values of simultaneous multi-slice accelerated diffusion-weighted imaging with motion-correction (DWI SMS Moco) to standard diffusion-weighted imaging (sDWI) in free-breathing abdominal magnetic resonance imaging (MRI) in pediatric and young adult patients with cystic fibrosis (CF). MATERIAL AND METHODS 16 patients (7 male and 9 female, 12-41 years old) with CF were examined prospectively in a single-center from November 2020 to March 2021 on a 1.5 Tesla clinical MR scanner. The characteristics of overall image quality and delimitability of mesenteric lymph nodes were evaluated using a 5-point Likert scale by two experienced pediatric radiologists independently from each other. Quantitative parameters with SNR and ADC values were assessed in 8 different locations and compared using a Wilcoxon signed-rank test. RESULTS The acquisition time for DWI SMS Moco was 32% shorter than for sDWI. Regarding quality comparison, overall image quality and delimitability of mesenteric lymph nodes were significant higher in DWI SMS Moco (p ≤ 0.05 for both readers). The readers preferred DWI SMS Moco to sDWI in all cases (16/16). Mean SNR values from DWI SMS Moco and sDWI were similar in 7 from 8 locations. The ADC values showed no significant difference between DWI SMS Moco and sDWI in any of the evaluated locations (p > 0.05). CONCLUSIONS The DWI SMS Moco improves overall image quality and delimitability of mesenteric lymph nodes compared to sDWI with similar SNR and ADC values and a distinguished reduction of scan time in free-breathing by one third. We conclude that MRI with DWI SMS Moco could be helpful in monitoring the effect of the high-efficiency modulator (HEM) therapy in cystic fibrosis (CF) patients homozygous or heterozygous for F508del in the abdomen.
Collapse
Affiliation(s)
- Katja Glutig
- Department of Radiology, Section Pediatric Radiology, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany.
| | - Paul-Christian Krüger
- Department of Radiology, Section Pediatric Radiology, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany
| | - Theresa Oberreuther
- Department of Radiology, Section Pediatric Radiology, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany
| | | | - Ulf Teichgräber
- Department of Radiology, Jena University Hospital, Jena, Germany
| | - Michael Lorenz
- Cystic Fibrosis Centre, Department of Paediatrics, Jena University Hospital, Jena, Germany
| | - Hans-Joachim Mentzel
- Department of Radiology, Section Pediatric Radiology, Jena University Hospital, Am Klinikum 1, 07747, Jena, Germany
| | - Martin Krämer
- Department of Radiology, Jena University Hospital, Jena, Germany
| |
Collapse
|
17
|
Khodarahmi I, Fritz J. The Value of 3 Tesla Field Strength for Musculoskeletal Magnetic Resonance Imaging. Invest Radiol 2021; 56:749-763. [PMID: 34190717 DOI: 10.1097/rli.0000000000000801] [Citation(s) in RCA: 45] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
ABSTRACT Musculoskeletal magnetic resonance imaging (MRI) is a careful negotiation between spatial, temporal, and contrast resolution, which builds the foundation for diagnostic performance and value. Many aspects of musculoskeletal MRI can improve the image quality and increase the acquisition speed; however, 3.0-T field strength has the highest impact within the current diagnostic range. In addition to the favorable attributes of 3.0-T field strength translating into high temporal, spatial, and contrast resolution, many 3.0-T MRI systems yield additional gains through high-performance gradients systems and radiofrequency pulse transmission technology, advanced multichannel receiver technology, and high-end surface coils. Compared with 1.5 T, 3.0-T MRI systems yield approximately 2-fold higher signal-to-noise ratios, enabling 4 times faster data acquisition or double the matrix size. Clinically, 3.0-T field strength translates into markedly higher scan efficiency, better image quality, more accurate visualization of small anatomic structures and abnormalities, and the ability to offer high-end applications, such as quantitative MRI and magnetic resonance neurography. Challenges of 3.0-T MRI include higher magnetic susceptibility, chemical shift, dielectric effects, and higher radiofrequency energy deposition, which can be managed successfully. The higher total cost of ownership of 3.0-T MRI systems can be offset by shorter musculoskeletal MRI examinations, higher-quality examinations, and utilization of advanced MRI techniques, which then can achieve higher gains and value than lower field systems. We provide a practice-focused review of the value of 3.0-T field strength for musculoskeletal MRI, practical solutions to challenges, and illustrations of a wide spectrum of gainful clinical applications.
Collapse
Affiliation(s)
- Iman Khodarahmi
- From the Division of Musculoskeletal Radiology, Department of Radiology, NYU Grossman School of Medicine, New York, NY
| | | |
Collapse
|
18
|
Xu H, Zhang N, Yang DW, Ren A, Ren H, Zhang Q, Zhu JX, Li GJ, Yang ZH. Feasibility study of simultaneous multislice diffusion kurtosis imaging with different acceleration factors in the liver. BMC Med Imaging 2021; 21:132. [PMID: 34503482 PMCID: PMC8431937 DOI: 10.1186/s12880-021-00661-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 08/28/2021] [Indexed: 12/02/2022] Open
Abstract
Background Simultaneous multislice diffusion-weighted imaging (SMS-DWI) has been used to reduce image acquisition time. The purpose of this study was to investigate the feasibility of diffusion kurtosis imaging (DKI) based on the SMS technique in the liver and the influence of this method compared with that of conventional DWI sequences on image quality and DKI-derived quantitative parameters. Methods Forty volunteers underwent SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI, SMS3-DWI) and conventional DWI (C-DWI) of the liver with three b-values (50, 800, 2000 s/mm2) in a 3T system. Qualitative image quality parameters and quantitative measurements of the signal-to-noise ratio (SNR), mean kurtosis (MK), mean apparent diffusivity (MD) and apparent diffusion coefficient (ADC) for the liver were compared between the three sequences. Results The scan times of C-DWI, SMS2-DWI, and SMS3-DWI were 4 min 11 s, 2 min 2 s, and 1 min 34 s, respectively. For all image quality parameters, there were no significant differences observed between C-DWI and SMS2-DWI (all p > 0.05) in the images with b-values of 800 and 2000 s/mm2. C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI (all p < 0.01) in the images with b-values of 2000 s/mm2. In the images with b-values of 800 s/mm2, C-DWI and SMS2-DWI exhibited better scores than SMS3-DWI for artefacts and overall image quality (all p < 0.01), and C-DWI exhibited better scores than SMS3-DWI for the visibility of intrahepatic vessels (p < 0.001). There were no significant differences in the sharpness of the right lobe edge (p = 0.144), conspicuity of the left lobe (p = 0.370) or visibility of intrahepatic vessels (p = 0.109) between SMS2-DWI and SMS3-DWI. There were no significant differences in the sharpness of the right lobe edge (p = 0.066) or conspicuity of the left lobe (p = 0.131) between C-DWI and SMS3-DWI. For the b-value of 800 s/mm2, there were no statistically significant differences between SMS2-DWI and C-DWI (p = 1.000) or between SMS2-DWI and SMS3-DWI (p = 0.059), whereas SMS3-DWI had a significantly lower SNR than C-DWI (p = 0.024). For the DKI-derived parameters (MK and MD) and ADC values, there were no significant differences between the three sequences (MK, p = 0.606; MD, p = 0.831; ADC, p = 0.264). Conclusions SMS-DWI with an acceleration factor of 2 is feasible for the liver, resulting in considerable reductions in scan time while maintaining similar image quality, comparable DKI parameters and ADC values compared with those of C-DWI.
Collapse
Affiliation(s)
- Hui Xu
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China
| | - Nan Zhang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China
| | - Da-Wei Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China
| | - Ahong Ren
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China
| | - Hao Ren
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China
| | - Qian Zhang
- Clinical Epidemiology and EBM Unit, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China
| | - Jin-Xia Zhu
- MR Collaboration, Siemens Healthineers Ltd., Beijing, China
| | - Gui-Jin Li
- MR Application, Siemens Healthineers Ltd., Guangzhou, China
| | - Zheng-Han Yang
- Department of Radiology, Beijing Friendship Hospital, Capital Medical University, 95 Yong an Road, Xicheng District, Beijing, 100050, China.
| |
Collapse
|
19
|
Scan Time Reduction in Intravoxel Incoherent Motion Diffusion-Weighted Imaging and Diffusion Kurtosis Imaging of the Abdominal Organs: Using a Simultaneous Multislice Technique With Different Acceleration Factors. J Comput Assist Tomogr 2021; 45:507-515. [PMID: 34270482 DOI: 10.1097/rct.0000000000001189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE To investigate the feasibility of quantitative intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) analyses in the upper abdominal organs by simultaneous multislice diffusion-weighted imaging (SMS-DWI). SUBJECTS AND METHODS In this prospective study, a total of 32 participants underwent conventional DWI (C-DWI) and SMS-DWI sequences with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) in the upper abdomen with multiple b-values (0, 10, 20, 50, 80, 100, 150, 200, 500, 800, 1000, 1500, and 2000 seconds/mm2) on a 3 T system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany). Image quality and quantitatively measurements of apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudodiffusion coefficient (D*), perfusion fraction (f), mean kurtosis (MK), and mean apparent diffusivity (MD) for the liver, pancreas, kidney cortex and medulla, spleen, and erector spine muscle were compared between the 3 sequences. RESULTS The acquisition times for C-DWI, SMS2-DWI, and SMS3-DWI were 10 minutes 57 seconds, 5 minutes 9 seconds, and 3 minutes 54 seconds. For image quality parameters, C-DWI and SMS2-DWI yielded better results than SMS3-DWI (P < 0.05). SMS2-DWI had equivalent IVIM and DKI parameters compared with that of C-DWI (P > 0.05). No statistically significant differences in the ADC, D, f, and MD values between the 3 sequences (P > 0.05) were observed. The D* and MK values of the liver (P = 0.005 and P = 0.012) and pancreas (P = 0.019) between SMS3-DWI and C-DWI were significantly different. CONCLUSIONS SMS2-DWI can substantially reduce the scan time while maintaining equivalent IVIM and DKI parameters in the abdominal organs compared with C-DWI.
Collapse
|
20
|
Tu C, Shen H, Liu D, Chen Q, Yuan X, Li X, Wang X, Liu R, Wang X, Li Q, Liu W, Zhang J. Simultaneous multi-slice readout-segmentation of long variable echo-trains for accelerated diffusion-weighted imaging of nasopharyngeal carcinoma: A feasibility and optimization study. Clin Imaging 2021; 79:119-124. [PMID: 33940488 DOI: 10.1016/j.clinimag.2021.04.009] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 03/27/2021] [Accepted: 04/12/2021] [Indexed: 12/29/2022]
Abstract
OBJECTIVES We aimed to evaluate the feasibility of simultaneous multi-slice readout segmentation of long variable echo-trains (SMS-RESOLVE) for diffusion-weighted imaging (DWI) of nasopharyngeal carcinoma (NPC) and determine the optimal acceleration factor of SMS-RESOLVE DWI compared with conventional RESOLVE DWI. MATERIALS AND METHODS One hundred and five patients with histologically confirmed NPC were enrolled. DWIs including conventional RESOLVE DWI, SMS-RESOLVE DWI with acceleration factors of 2 and 3 (2 × SMS-RESOLVE and 3 × SMS-RESOLVE) were acquired at b-values of 0 and 800 s/mm2. The subjective image quality, including overall image quality, lesion conspicuity, and lesion distortion scores, and objective image quality, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast in these three protocols, were assessed and compared. The apparent diffusion coefficients (ADCs) of the primary tumor and right masseter muscle and normalized ADCs in the three protocols were measured and compared. RESULTS The 2 × SMS-RESOLVE provided comparable image quality and ADCs with a 48.3% reduction in scan time compared with conventional RESOLVE DWI. The 3 × SMS-RESOLVE showed significantly poorer image quality and the highest ADCs with a 56.9% reduction in scan times compared with conventional RESOLVE DWI. CONCLUSION The SMS-RESOLVE DWI with an acceleration factor of 2 yielded the best compromise between image quality and scan time reduction and could be an alternative to conventional RESOLVE DWI for nasopharyngeal carcinoma.
Collapse
Affiliation(s)
- Chunrong Tu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Hesong Shen
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Daihong Liu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qiuzhi Chen
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoqian Yuan
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoqin Li
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xing Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Renwei Liu
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Xiaoxia Wang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China
| | - Qing Li
- MR Collaborations, Siemens Healthcare Ltd., Shanghai, China
| | - Wei Liu
- MR Application Development, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen, China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital, Chongqing, China.
| |
Collapse
|
21
|
Hu Y, Zhan C, Yang Z, Zhang X, Zhang H, Liu W, Xia L, Ai T. Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions. Eur Radiol 2020; 31:2667-2676. [PMID: 33146797 DOI: 10.1007/s00330-020-07393-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 09/09/2020] [Accepted: 10/08/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To investigate the feasibility and effectiveness of SMS rs-EPI for evaluating breast lesions. METHODS This prospective study was approved by IRB. Ninety-six patients had 102 histopathologically verified lesions (80 malignant and 22 benign) that were evaluated. Conventional rs-EPI and SMS rs-EPI data were acquired on a 3T scanner. Mean kurtosis (MK), mean diffusion (MD), and apparent diffusion coefficient (ADC) values were quantitatively calculated for each lesion on both sequences. Images were qualitatively and quantitatively analyzed with respect to image sharpness, geometric distortion, lesion conspicuity, anatomic structure, overall image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Student's t test, Pearson correlation, receiver operating characteristic curve, Wilcoxon rank sum test, and paired-sample t tests were used for statistical analysis. RESULTS Compared to conventional rs-EPI, the acquisition time of SMS rs-EPI was markedly reduced (2:17 min vs 4:27 min). Pearson's correlations showed excellent linear relationships for each parameter between conventional rs-EPI and SMS rs-EPI (MK, r = 0.908; MD, r = 0.938; and ADC, r = 0.975; p < 0.01 for all). Furthermore, SMS rs-EPI had similar diagnostic performance compared with conventional rs-EPI. SMS rs-EPI had comparable visual image quality as conventional rs-EPI, with excellent inter-reader reliability (ICC = 0.851-0.940). No differences existed between conventional rs-EPI and SMS rs-EPI for either SNR or CNR (p > 0.05). CONCLUSIONS Applying the SMS technique can significantly reduce the acquisition time and produce similar diagnostic accuracy while generating comparable image quality as the conventional rs-EPI. KEY POINTS • SMS rs-EPI reduces scan time from 4:27 min to 2:17 min compared with conventional rs-EPI. • SMS rs-EPI has a comparable diagnostic performance to conventional rs-EPI in the differentiation between malignant and benign breast lesions. • SMS rs-EPI demonstrates comparable image quality to conventional rs-EPI with shorter scan time.
Collapse
Affiliation(s)
- Yiqi Hu
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Chenao Zhan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Zhenlu Yang
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Xiaoyong Zhang
- MR Collaborations, Siemens Healthcare, Shenzhen, 518000, China
| | - Huiting Zhang
- MR Scientific Marketing, Siemens Healthcare, Wuhan, 430030, Hubei, China
| | - Wei Liu
- Siemens Shenzhen Magnetic Resonance, Shenzhen, 518000, China
| | - Liming Xia
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China
| | - Tao Ai
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, Hubei, China.
| |
Collapse
|
22
|
Attenberger UI, Tavakoli A, Stocker D, Stieb S, Riesterer O, Turina M, Schoenberg SO, Pilz L, Reiner CS. Reduced and standard field-of-view diffusion weighted imaging in patients with rectal cancer at 3 T-Comparison of image quality and apparent diffusion coefficient measurements. Eur J Radiol 2020; 131:109257. [PMID: 32947092 DOI: 10.1016/j.ejrad.2020.109257] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 06/30/2020] [Accepted: 08/24/2020] [Indexed: 01/03/2023]
Abstract
PURPOSE To compare a zoomed EPI-DWI (z-EPI) with a standard EPI-DWI (s-EPI) in the primary diagnostics of rectal cancer and assess its potential of reduced image artifacts. METHOD 22 therapy-naïve patients with rectal cancer underwent rectal MRI at a 3 T-system. The protocols consisted of a z-EPI DWI and s-EPI DWI sequence. Images were assessed by two independent and experienced readers regarding overall image quality and artifacts on a 5-point Likert scale, as well as overall sequence preference. In a lesion-based analysis, tumor and lymph node detection were rated on a 4-point Likert scale. Apparent diffusion coefficient (ADC) measurements were performed. RESULTS Overall Image quality score for z-EPI and s-EPI showed no statistically significant differences (p = 0.80/0.54, reader 1/2) with a median score of 4 ("good" image quality) for both sequences. The image quality preference rank for z-EPI and s-EPI was given the category 'no preference' in 64 % (reader 1) and 50 % (reader 2). Most artifact-related scores (susceptibility, motion and distortion) did not show reproducible significant differences between z-EPI and s-EPI. The two sequences exhibited comparable, mostly good and excellent quality scores for tumor and lymph node detection (p = 0.19-0.99). ADC values were significantly lower for z-EPI than for s-EPI (p = 0.001/0.002, reader 1/2) with good agreement of ADC measurements between both readers. CONCLUSION Our data showed comparable image quality and lesion detection for the z-EPI and the s-EPI sequence in MRI of rectal cancer, whereas the mean ADC of the tumor was significantly lower in z-EPI compared to s-EPI.
Collapse
Affiliation(s)
- U I Attenberger
- Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany.
| | - A Tavakoli
- Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany; Department of Radiology, German Cancer Research Center (DKFZ), Germany.
| | - D Stocker
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
| | - S Stieb
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - O Riesterer
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland.
| | - M Turina
- Department of Surgery and Transplantation, University Hospital Zurich, Zurich, Switzerland.
| | - S O Schoenberg
- Department of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Germany.
| | - L Pilz
- Medical Faculty Mannheim, University of Heidelberg, Mannheim, Germany.
| | - C S Reiner
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland.
| |
Collapse
|
23
|
Park JH, Seo N, Lim JS, Hahm J, Kim MJ. Feasibility of Simultaneous Multislice Acceleration Technique in Diffusion-Weighted Magnetic Resonance Imaging of the Rectum. Korean J Radiol 2020; 21:77-87. [PMID: 31920031 PMCID: PMC6960306 DOI: 10.3348/kjr.2019.0406] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 09/17/2019] [Indexed: 12/17/2022] Open
Abstract
Objective To assess the feasibility of simultaneous multislice-accelerated diffusion-weighted imaging (SMS-DWI) of the rectum in comparison with conventional DWI (C-DWI) in rectal cancer patients. Materials and Methods This study included 65 patients with initially-diagnosed rectal cancer. All patients underwent C-DWI and SMS-DWI with acceleration factors of 2 and 3 (SMS2-DWI and SMS3-DWI, respectively) using a 3T scanner. Acquisition times of the three DWI sequences were measured. Image quality in the three DWI sequences was reviewed by two independent radiologists using a 4-point Likert scale and subsequently compared using the Friedman test. Apparent diffusion coefficient (ADC) values for rectal cancer and the normal rectal wall were compared among the three sequences using repeated measures analysis of variance. Results Acquisition times using C-DWI, SMS2-DWI, and SMS3-DWI were 173 seconds, 107 seconds, (38.2% shorter than C-DWI), and 77 seconds (55.5% shorter than C-DWI), respectively. For all image quality parameters other than distortion (margin sharpness, artifact, lesion conspicuity, and overall image quality), C-DWI and SMS2-DWI yielded better results than did SMS3-DWI (Ps < 0.001), with no significant differences observed between C-DWI and SMS2-DWI (Ps ≥ 0.054). ADC values of rectal cancer (p = 0.943) and normal rectal wall (p = 0.360) were not significantly different among C-DWI, SMS2-DWI, and SMS3-DWI. Conclusion SMS-DWI using an acceleration factor of 2 is feasible for rectal MRI resulting in substantial reductions in acquisition time while maintaining diagnostic image quality and similar ADC values to those of C-DWI.
Collapse
Affiliation(s)
- Jae Hyon Park
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Nieun Seo
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| | - Joon Seok Lim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| | | | - Myeong Jin Kim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
24
|
Chan WY, Hartono S, Thng CH, Koh DM. New Advances in Magnetic Resonance Techniques in Abdomen and Pelvis. Magn Reson Imaging Clin N Am 2020; 28:433-445. [PMID: 32624160 DOI: 10.1016/j.mric.2020.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
This article explores new acquisition methods in magnetic resonance (MR) imaging to provide high spatial and temporal resolution imaging for a wide spectrum of clinical applications in the abdomen and pelvis. We present an overview of some of these advanced MR techniques, such as non-cartesian image acquisition, fast sampling and compressed sensing, diffusion quantification and quantitative MR that can improve data sampling, enhance image quality, yield quantitative measurements, and/or optimize diagnostic performance in the body.
Collapse
Affiliation(s)
- Wan Ying Chan
- Division of Oncologic Imaging, National Cancer Centre, 11 Hospital Crescent, Singapore 169610, Singapore
| | - Septian Hartono
- Department of Neurology, National Neuroscience Institute, Singapore, 11 Jln Tan Tock Seng, Singapore 308433, Singapore
| | - Choon Hua Thng
- Division of Oncologic Imaging, National Cancer Centre, 11 Hospital Crescent, Singapore 169610, Singapore
| | - Dow-Mu Koh
- Department of Radiology, Royal Marsden Hospital, Downs Road, Sutton SM2 5PT, UK.
| |
Collapse
|
25
|
Buus TW, Sivesgaard K, Jensen AB, Pedersen EM. Simultaneous multislice diffusion-weighted imaging with short tau inversion recovery fat suppression in bone-metastasizing breast cancer. Eur J Radiol 2020; 130:109142. [PMID: 32619754 DOI: 10.1016/j.ejrad.2020.109142] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 06/02/2020] [Accepted: 06/14/2020] [Indexed: 02/04/2023]
Abstract
PURPOSE To compare image quality and ADC values of simultaneous multislice diffusion-weighted imaging (mb-DWI) with that of conventional DWI (c-DWI) using short tau inversion recovery fat saturation (STIR) in women with bone-metastasizing breast cancer. METHOD c-DWI and mb-DWI were acquired at 1.5 T in 23 breast cancer patients from skull base to mid thighs. mb-DWI was compared to c-DWI in terms of subjective image quality, artefacts and bone metastasis lesion conspicuity assessed on a 5-point Likert scale. ADC values of different organs as well as bone metastasis ADC values were compared between c-DWI and mb-DWI. RESULTS mb-DWI reduced scan time by 48 % compared with c-DWI (1 min 58 s vs. 3 min 45 s per station). mb-DWI provided similar subjective image quality (3.8 vs. 3.7, p = 0.70), number of artefacts (50 vs. 56), severity of these (4.6 vs. 4.7, p = 0.11), and lesion conspicuity (4.2 vs. 4.4, p = 0.31) compared to c-DWI. mb-DWI showed lower mean ADC values in liver (0.5 × 10-3 mm2/s vs. 0.7 × 10-3 mm2/s, p = 0.002) and erector spine muscle (1.3 × 10-3 mm2/s vs. 1.5 × 10-3 mm2/s, p < 0.001). Bone metastasis ADC values from mb-DWI were 6.4 % lower than c-DWI (95 % confidence interval: 5.4%-7.4%, p < 0.001). CONCLUSIONS mb-DWI provides similar subjective image quality to c-DWI with the same level of artefacts. Although bone metastasis ADC values were lower, mb-DWI can substantially reduce scan times of whole-body DWI in women with bone-metastasizing breast cancer.
Collapse
Affiliation(s)
- Thomas Winther Buus
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark.
| | - Kim Sivesgaard
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
| | - Anders Bonde Jensen
- Department of Oncology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
| | - Erik Morre Pedersen
- Department of Radiology, Aarhus University Hospital, Palle Juul-Jensens Boulevard 99, 8200 Aarhus N, Denmark
| |
Collapse
|
26
|
|
27
|
Improved Liver Diffusion-Weighted Imaging at 3 T Using Respiratory Triggering in Combination With Simultaneous Multislice Acceleration. Invest Radiol 2020; 54:744-751. [PMID: 31335634 DOI: 10.1097/rli.0000000000000594] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
OBJECTIVES The aim of this study was to retrospectively compare optimized respiratory-triggered diffusion-weighted imaging with simultaneous multislice acceleration (SMS-RT-DWI) of the liver with a standard free-breathing echo-planar DWI (s-DWI) protocol at 3 T with respect to the imaging artifacts inherent to DWI. MATERIALS AND METHODS Fifty-two patients who underwent a magnetic resonance imaging study of the liver were included in this retrospective study. Examinations were performed on a 3 T whole-body magnetic resonance system (MAGNETOM Skyra; Siemens Healthcare, Erlangen, Germany). In all patients, both s-DWI and SMS-RT-DWI of the liver were obtained. Images were qualitatively evaluated by 2 independent radiologists with regard to overall image quality, liver edge sharpness, sequence-related artifacts, and overall scan preference. For quantitative evaluation, signal-to-noise ratio was measured from signal-to-noise ratio maps. The mean apparent diffusion coefficient (ADC) was measured in each liver quadrant. The Wilcoxon rank-sum test was used for analysis of the qualitative parameters and the paired Student t test for quantitative parameters. RESULTS Overall image quality, liver edge sharpness, and sequence-related artifacts of SMS-RT-DWI received significantly better ratings compared with s-DWI (P < 0.05 for all). For 90.4% of the examinations, both readers overall preferred SMS-RT-DWI to s-DWI. Acquisition time for SMS-RT-DWI was 34% faster than s-DWI. Signal-to-noise ratio values were significantly higher for s-DWI at b50 but did not statistically differ at b800, and they were more homogenous for SMS-RT-DWI, with a significantly lower standard deviation at b50. Mean ADC values decreased from the left to right hepatic lobe as well as from cranial to caudal for s-DWI. With SMS-RT-DWI, mean ADC values were homogeneous throughout the liver. CONCLUSIONS Optimized, multislice, respiratory-triggered DWI of the liver at 3 T substantially improves image quality with a reduced scan acquisition time compared with s-DWI.
Collapse
|
28
|
|
29
|
Szklaruk J, Son JB, Wei W, Bhosale P, Javadi S, Ma J. Comparison of free breathing and respiratory triggered diffusion-weighted imaging sequences for liver imaging. World J Radiol 2019; 11:134-143. [PMID: 31798795 PMCID: PMC6885723 DOI: 10.4329/wjr.v11.i11.134] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 08/26/2019] [Accepted: 09/26/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) has become a useful tool in the detection, characterization, and evaluation of response to treatment of many cancers, including malignant liver lesions. DWI offers higher image contrast between lesions and normal liver tissue than other sequences. DWI images acquired at two or more b-values can be used to derive an apparent diffusion coefficient (ADC). DWI in the body has several technical challenges. This include ghosting artifacts, mis-registration and susceptibility artifacts. New DWI sequences have been developed to overcome some of these challenges. Our goal is to evaluate 3 new DWI sequences for liver imaging.
AIM To qualitatively and quantitatively compare 3 DWI sequences for liver imaging: free-breathing (FB), simultaneous multislice (SMS), and prospective acquisition correction (PACE).
METHODS Magnetic resonance imaging (MRI) was performed in 20 patients in this prospective study. The MR study included 3 separate DWI sequences: FB-DWI, SMS-DWI, and PACE-DWI. The image quality, mean ADC, standard deviations (SD) of ADC, and ADC histogram were compared. Wilcoxon signed-rank tests were used to compare qualitative image quality. A linear mixed model was used to compare the mean ADC and the SDs of the ADC values. All tests were 2-sided and P values of < 0.05 were considered statistically significant.
RESULTS There were 56 lesions (50 malignant) evaluated in this study. The mean qualitative image quality score of PACE-DWI was 4.48. This was significantly better than that of SMS-DWI (4.22) and FB-DWI (3.15) (P < 0.05). Quantitatively, the mean ADC values from the 3 different sequences did not significantly differ for each liver lesion. FB-DWI had a markedly higher variation in the SD of the ADC values than did SMS-DWI and PACE-DWI. We found statistically significant differences in the SDs of the ADC values for FB-DWI vs PACE-DWI (P < 0.0001) and for FB-DWI vs SMS-DWI (P = 0.03). The SD of the ADC values was not statistically significant for PACE-DWI and SMS-DWI (P = 0.18). The quality of the PACE-DWI ADC histograms were considered better than the SMS-DWI and FB-DWI.
CONCLUSION Compared to FB-DWI, both PACE-DWI and SMS-DWI provide better image quality and decreased quantitative variability in the measurement of ADC values of liver lesions.
Collapse
Affiliation(s)
- Janio Szklaruk
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Jong Bum Son
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Wei Wei
- Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Priya Bhosale
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Sanaz Javadi
- Department of Diagnostic Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| | - Jingfei Ma
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States
| |
Collapse
|
30
|
Simultaneous Multislice Echo Planar Imaging for Accelerated Diffusion-Weighted Imaging of Malignant and Benign Breast Lesions. Invest Radiol 2019; 54:524-530. [DOI: 10.1097/rli.0000000000000560] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
31
|
Modulating Diffusion-Weighted Magnetic Resonance Imaging for Screening in Oncologic Tertiary Prevention: A Prospective Ex Vivo and In Vivo Study. Invest Radiol 2019; 54:704-711. [PMID: 31356384 DOI: 10.1097/rli.0000000000000596] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Diffusion-weighted imaging (DWI) is an important part of oncological magnetic resonance imaging (MRI) examinations, especially for tertiary cancer prevention in terms of early detection of recurrent disease. However, abdominal studies can be challenged by motion artifacts, poor signal-to-noise ratios, and visibility of retroperitoneal structures, which necessitates sequence optimization depending on the investigated region. This study aims at prospectively evaluating an adapted DWI sequence ex vivo and in vivo in oncologic patients undergoing abdominal MRI. METHODS This institutional review board-approved, prospective study included phantom measurements, volunteer examinations, and oncologic patient examinations of the abdomen. Fifty-seven MRI examinations in 54 patients (mean age, 58 years; range, 21-90 years) were included into the analysis. The MRI examination were performed at a 1.5 T MRI scanner (MAGNETOM Aera; Siemens Healthcare, Erlangen, Germany) and included both a standard EPI-DWI (s-DWI; b = 50, 900 s/mm) and an adapted DWI (opt-DWI; EPI-DWI with b = 0, 50, 900, 1500 s/mm, acquisition with higher spatial resolution and optimized processing for the abdomen including motion correction, adaptive image combination, and background suppression). For b = 900 s/mm, the ratio of signal intensity in the normal tissue and the standard deviation of the noise in the surrounding air was quantitatively calculated; image quality and tissue differentiation parameters were rated by 2 independent, blinded readers using a 5-point Likert scale. Statistics included Wilcoxon signed-rank test and kappa statistic (P < 0.05/0.0125 after Bonferroni correction). RESULTS The DWI phantom demonstrated an optimized contour sharpness and inlay differentiation for opt-DWI. The apparent ratio of normal tissue signal/standard deviation of background noise at b = 900 s/mm of the right/left hemiabdomen was significantly increased in opt-DWI (mean, 71.9 ± 23.5/86.0 ± 43.3) versus s-DWI (mean, 51.4 ± 15.4/63.4 ± 36.5; P < 0.001). Image quality parameters (contour sharpness and tissue differentiation of upper abdominal and retroperitoneal structures) were significantly increased in opt-DWI versus s-DWI (P < 0.001). Interreader reliability test showed good agreement (kappa = 0.768; P < 0.001). DISCUSSION This study prospectively evaluated the potential of adapted DWI for screening in tertiary prevention of oncologic patients. An optimized DWI protocol with advanced processing achieved improved image quality in quantitative and qualitative analyses. Oncological optimization of DWI should be performed before its application in cancer patients to improve both screening and follow-up examinations, to better unleash the diagnostic potential of DWI.
Collapse
|
32
|
Performance of an Automated Versus a Manual Whole-Body Magnetic Resonance Imaging Workflow. Invest Radiol 2019; 53:463-471. [PMID: 29697493 DOI: 10.1097/rli.0000000000000471] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the performance of an automated workflow for whole-body magnetic resonance imaging (WB-MRI), which reduces user interaction compared with the manual WB-MRI workflow. MATERIALS AND METHODS This prospective study was approved by the local ethics committee. Twenty patients underwent WB-MRI for myopathy evaluation on a 3 T MRI scanner. Ten patients (7 women; age, 52 ± 13 years; body weight, 69.9 ± 13.3 kg; height, 173 ± 9.3 cm; body mass index, 23.2 ± 3.0) were examined with a prototypical automated WB-MRI workflow, which automatically segments the whole body, and 10 patients (6 women; age, 35.9 ± 12.4 years; body weight, 72 ± 21 kg; height, 169.2 ± 10.4 cm; body mass index, 24.9 ± 5.6) with a manual scan. Overall image quality (IQ; 5-point scale: 5, excellent; 1, poor) and coverage of the study volume were assessed by 2 readers for each sequence (coronal T2-weighted turbo inversion recovery magnitude [TIRM] and axial contrast-enhanced T1-weighted [ce-T1w] gradient dual-echo sequence). Interreader agreement was evaluated with intraclass correlation coefficients. Examination time, number of user interactions, and MR technicians' acceptance rating (1, highest; 10, lowest) was compared between both groups. RESULTS Total examination time was significantly shorter for automated WB-MRI workflow versus manual WB-MRI workflow (30.0 ± 4.2 vs 41.5 ± 3.4 minutes, P < 0.0001) with significantly shorter planning time (2.5 ± 0.8 vs 14.0 ± 7.0 minutes, P < 0.0001). Planning took 8% of the total examination time with automated versus 34% with manual WB-MRI workflow (P < 0.0001). The number of user interactions with automated WB-MRI workflow was significantly lower compared with manual WB-MRI workflow (10.2 ± 4.4 vs 48.2 ± 17.2, P < 0.0001). Planning efforts were rated significantly lower by the MR technicians for the automated WB-MRI workflow than for the manual WB-MRI workflow (2.20 ± 0.92 vs 4.80 ± 2.39, respectively; P = 0.005). Overall IQ was similar between automated and manual WB-MRI workflow (TIRM: 4.00 ± 0.94 vs 3.45 ± 1.19, P = 0.264; ce-T1w: 4.20 ± 0.88 vs 4.55 ± .55, P = 0.423). Interreader agreement for overall IQ was excellent for TIRM and ce-T1w with an intraclass correlation coefficient of 0.95 (95% confidence interval, 0.86-0.98) and 0.88 (95% confidence interval, 0.70-0.95). Incomplete coverage of the thoracic compartment in the ce-T1w sequence occurred more often in the automated WB-MRI workflow (P = 0.008) for reader 2. No other significant differences in the study volume coverage were found. CONCLUSIONS In conclusion, the automated WB-MRI scanner workflow showed a significant reduction of the examination time and the user interaction compared with the manual WB-MRI workflow. Image quality and the coverage of the study volume were comparable in both groups.
Collapse
|
33
|
Intra-individual comparison of conventional and simultaneous multislice-accelerated diffusion-weighted imaging in upper abdominal solid organs: value of ADC normalization using the spleen as a reference organ. Abdom Radiol (NY) 2019; 44:1808-1815. [PMID: 30737546 DOI: 10.1007/s00261-019-01924-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
PURPOSE To compare the apparent diffusion coefficient (ADC) value of conventional diffusion-weighted imaging (cDWI) to simultaneous multislice-accelerated DWI (sDWI) and to evaluate the possibility of ADC normalization using the spleen as a reference organ. METHODS We retrospectively evaluated 92 patients (68 men, 24 women; mean age 60.0 years) who underwent liver magnetic resonance imaging (MRI) including both cDWI and sDWI. sDWI was obtained with an acceleration factor of 2. ADC values were measured from the right liver lobe, left liver lobe, spleen, pancreas, right kidney, and left kidney. ADC values of the spleen were used for normalization. Paired sample t test, Pearson's correlation coefficient, and Bland-Altman method were used for statistical analysis. RESULTS ADC values of cDWI were significantly lower than sDWI in all six anatomic regions (p < 0.001). The mean difference in ADC value between cDWI and sDWI ranged from 0.048 to 0.125 × 10-3 mm2/s. ADC values from cDWI and sDWI showed a moderate to very high positive correlation (p < 0.001). After ADC normalization using the spleen as a reference organ, there was no significant difference between normalized ADC of cDWI and sDWI in all 5 anatomic regions (p = 0.11 - 0.74). CONCLUSIONS Normalization of ADC using the spleen could be useful for comparing upper abdominal organs acquired with either cDWI or sDWI in longitudinal and follow-up studies.
Collapse
|
34
|
Zhang G, Sun H, Qian T, An J, Shi B, Zhou H, Liu Y, Peng X, Liu Y, Chen L, Jin Z. Diffusion-weighted imaging of the kidney: comparison between simultaneous multi-slice and integrated slice-by-slice shimming echo planar sequence. Clin Radiol 2019; 74:325.e1-325.e8. [DOI: 10.1016/j.crad.2018.12.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Accepted: 12/11/2018] [Indexed: 12/13/2022]
|
35
|
Wang P, Wang D, Zhang J, Bai R, Qian M, Sun Y, Lu Y, Zhang X. Evaluation of Submillimeter Diffusion Imaging of the Macaque Brain Using Readout-Segmented EPI at 7 T. IEEE Trans Biomed Eng 2019; 66:2945-2951. [PMID: 30762524 DOI: 10.1109/tbme.2019.2899132] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE The purpose of the present study was to achieve submillimeter-level diffusion tensor imaging (DTI) of the macaque brain by using diffusion weighted (DW) readout-segmented echo planar imaging (rsEPI) with an optimized protocol at 7 T MRI. METHODS Three anesthetized macaques were included in this study. Under different scan settings, we compared the signal-to-noise ratio (SNR) and geometric distortion of DW images, implemented an optimized protocol for submillimeter-level DTI acquisition, and evaluated its performance. RESULTS The parallel-imaging-enabled (in GRAPPA mode) monopolar or monopolar+ diffusion scheme has higher SNR versus bipolar scheme, whereas trivial differences in SNR and image geometric distortion occurred when using increased readout segments with monopolar and monopolar+ that did not reach statistical significance. Submillimeter-level (0.8 mm isotropic) DTI data provide a sharper delineation of white matter contour than the 1 mm level. CONCLUSION The rsEPI technique with parallel imaging enabled, and with the shortest readout segments in conjunction with monopolar/monopolar+ diffusion encoding scheme, may be optimal for submillimeter-level diffusion imaging over macaque brains in vivo. SIGNIFICANCE rsEPI could effectively merit high-resolution DTI for in vivo macaque brain submillimeter structural architecture investigations at ultrahigh fields.
Collapse
|
36
|
Implementation of a 5-Minute Magnetic Resonance Imaging Screening Protocol for Prostate Cancer in Men With Elevated Prostate-Specific Antigen Before Biopsy. Invest Radiol 2019; 53:186-190. [PMID: 29077588 DOI: 10.1097/rli.0000000000000427] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
PURPOSE The aims of this study were to establish a 5-minute magnetic resonance (MR) screening protocol for prostate cancer in men before biopsy and to evaluate effects on Prostate Imaging Reporting and Data System (PI-RADS) V2 scoring in comparison to a conventional, fully diagnostic multiparametric MR imaging (mpMRI) approach. MATERIALS AND METHODS Fifty-two patients with elevated prostate-specific antigen levels and without prior biopsy were prospectively included in this institutional review board-approved study. In all patients, an mpMRI protocol according to the PI-RADS recommendations was acquired on a 3 T MRI system. In addition, an accelerated diffusion-weighted imaging sequence was acquired using simultaneous multislice technique (DW-EPISMS). Two readers independently evaluated the images for the presence/absence of prostate cancer according to the PI-RADS criteria and for additional findings. In a first reading session, only the screening protocol consisting of axial T2-weighted and DW-EPISMS images was made available. In a subsequent reading session, the mpMRI protocol was assessed blinded to the results of the first reading, serving as reference standard. RESULTS Both readers successfully established a final diagnosis according to the PI-RADS criteria in the screening and mpMRI protocol. Mean lesion size was 1.2 cm in the screening and 1.4 cm in the mpMRI protocol (P = 0.4) with 35% (18/52) of PI-RADS IV/V lesions. Diagnostic performance of the screening protocol was excellent with a sensitivity and specificity of 100% for both readers with no significant differences in comparison to the mpMRI standard (P = 1.0). In 3 patients, suspicious lymph nodes were reported as additional finding, which were equally detectable in the screening and mpMRI protocol. CONCLUSIONS A 5-minute MR screening protocol for prostate cancer in men with elevated prostate-specific antigen levels before biopsy is applicable for clinical routine with similar diagnostic performance as the full diagnostic mpMRI approach.
Collapse
|
37
|
Lateral geniculate nucleus volumetry at 3T and 7T: Four different optimized magnetic-resonance-imaging sequences evaluated against a 7T reference acquisition. Neuroimage 2018; 186:399-409. [PMID: 30342237 DOI: 10.1016/j.neuroimage.2018.09.046] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 08/24/2018] [Accepted: 09/17/2018] [Indexed: 11/20/2022] Open
Abstract
PURPOSE The lateral geniculate nucleus (LGN) is an essential nucleus of the visual pathway, occupying a small volume (60-160 mm3) among the other thalamic nuclei. The reported LGN volumes vary greatly across studies due to technical limitations and due to methodological differences of volume assessment. Yet, structural and anatomical alterations in ophthalmologic and neurodegenerative pathologies can only be revealed by a precise and reliable LGN representation. To improve LGN volume assessment, we first implemented a reference acquisition for LGN volume determination with optimized Contrast to Noise Ratio (CNR) and high spatial resolution. Next, we compared CNR efficiency and rating reliability of 3D Magnetization Prepared Rapid Gradient Echo (MPRAGE) images using white matter nulled (WMn) and grey matter nulled (GMn) sequences and its subtraction (WMn-GMn) relative to the clinical standard Proton Density Turbo Spin Echo (PD 2D TSE) and the reference acquisition. We hypothesized that 3D MPRAGE should provide a higher CNR and volume determination accuracy than the currently used 2D sequences. MATERIALS AND METHODS In 31 healthy subjects, we obtained at 3 and 7 T the following MR sequences: PD-TSE, MPRAGE with white/grey matter signal nulled (WMn/GMn), and a motion-corrected segmented MPRAGE sequence with a resolution of 0.4 × 0.4 × 0.4 mm3 (reference acquisition). To increase CNR, GMn were subtracted from WMn (WMn-GMn). Four investigators manually segmented the LGN independently. RESULTS The reference acquisition provided a very sharp depiction of the LGN and an estimated mean LGN volume of 124 ± 3.3 mm3. WMn-GMn had the highest CNR and gave the most reproducible LGN volume estimations between field strengths. Even with the highest CNR efficiency, PD-TSE gave inconsistent LGN volumes with the weakest reference acquisition correlation. The LGN WM rim induced a significant difference between LGN volumes estimated from WMn and GMn. WMn and GMn LGN volume estimations explained most of the reference acquisition volumes' variance. For all sequences, the volume rating reliability were good. On the other hand, the best CNR rating reliability, LGN volume and CNR correlations with the reference acquisition were obtained with GMn at 7 T. CONCLUSION WMn and GMn MPRAGE allow reliable LGN volume determination at both field strengths. The precise location and identification of the LGN (volume) can help to optimize neuroanatomical and neurophysiological studies, which involve the LGN structure. Our optimized imaging protocol may be used for clinical applications aiming at small nuclei volumetric and CNR quantification.
Collapse
|
38
|
Ciritsis A, Rossi C, Marcon M, Van VDP, Boss A. Accelerated diffusion-weighted imaging for lymph node assessment in the pelvis applying simultaneous multislice acquisition: A healthy volunteer study. Medicine (Baltimore) 2018; 97:e11745. [PMID: 30095628 PMCID: PMC6133413 DOI: 10.1097/md.0000000000011745] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
To evaluate the feasibility of accelerated simultaneous multislice diffusion weighted sequences (SMS-DWI) for lymph node detection in the abdominopelvic region. Sequences were evaluated regarding the number and depiction of lymph nodes detected with SMS-DWI compared with conventional diffusion weighted sequences, the most suitable SMS- acceleration factor, signal-to-noise ratio (SNR), and the overall acquisition time (TA).Eight healthy volunteers (4 men, 4 women; age range 21-39 years; median age 25 years) were examined in the pelvic region at 3T using a conventional DWI sequence and a SMS DWI sequence with different acceleration factors (AF: 2-3). Moreover, a SMS DWI sequence with AF 3 and higher slice resolution was applied. For morphological correlation of the lymph nodes and as a reference standard, an isotropic 3-dimensional T2-weighted fast-spin-echo sequence with high sampling efficiency (SPACE) was acquired. Two radiologists reviewed each DWI sequence and assessed the number of lymph nodes and the overall image quality. For each DWI sequence, SNR, SNR efficiency per time, contrast to noise (CNR), and ADC values were calculated. Values were statistically compared using a Wilcoxon test (P < .05).Overall, scan time of SMS-DWI with AF2 (AF3) decreased by 46.9% (57.2%) with respect to the conventional DWI. Compared with the SPACE sequence, the detection rate was 89.6% for conventional DWI, 69.4% for SMS-DWI with AF2, and 59.9% for SMS-DWI with AF3. The highly resolved SMS-DWI with AF3 leads to a scan time reduction of 46.9% and detection rate of 83.0%. SNR and CNR were lower in the accelerated sequences (up to 51.0%, P < .001) as compared with the conventional DWI. SNR efficiency decreased to 19.3% for AF2 and to 31.3% for AF3. In the highly resolved dataset, an SNR efficiency reduction of 51.2% was found.This study showed that lymph node detection in the abdominopelvic region with accelerated SMS-DWI sequences is feasible whereby an AF of 2 represents the best compromise between image quality, SNR, CNR, TA, and detection rate.
Collapse
|
39
|
|
40
|
Clinical Robustness of Accelerated and Optimized Abdominal Diffusion-Weighted Imaging. Invest Radiol 2017; 52:590-595. [DOI: 10.1097/rli.0000000000000370] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
41
|
|
42
|
Esses SJ, Lu X, Zhao T, Shanbhogue K, Dane B, Bruno M, Chandarana H. Automated image quality evaluation of T 2 -weighted liver MRI utilizing deep learning architecture. J Magn Reson Imaging 2017; 47:723-728. [PMID: 28577329 DOI: 10.1002/jmri.25779] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 05/15/2017] [Indexed: 12/13/2022] Open
Abstract
PURPOSE To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2 -weighted (T2 WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. MATERIALS AND METHODS We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T2 WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T2 WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T2 WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. RESULTS There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). CONCLUSION We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T2 WI of the liver. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723-728.
Collapse
Affiliation(s)
- Steven J Esses
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | | | - Tiejun Zhao
- Siemens Healthineers, New York, New York, USA
| | - Krishna Shanbhogue
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Bari Dane
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Mary Bruno
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| | - Hersh Chandarana
- Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, New York, USA
| |
Collapse
|