1
|
Boccalini S, Mayard C, Lacombe H, Villien M, Si-Mohamed S, Delahaye F, Boussel L, Budde RPJ, Pozzi M, Douek P. Ultra-High-Resolution and K-Edge Imaging of Prosthetic Heart Valves With Spectral Photon-Counting CT: A Phantom Study. Invest Radiol 2024; 59:589-598. [PMID: 38421666 DOI: 10.1097/rli.0000000000001068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
BACKGROUND AND PURPOSE The contribution of cardiac computed tomography (CT) for the detection and characterization of prosthetic heart valve (PHV) complications is still limited due mainly to artifacts. Computed tomography systems equipped with photon-counting detectors (PCDs) have the potential to overcome these limitations. Therefore, the aim of the study was to compare image quality of PHV with PCD-CT and dual-energy dual-layer CT (DEDL-CT). MATERIALS AND METHODS Two metallic and 3 biological PHVs were placed in a tube containing diluted iodinated contrast inside a thoracic phantom and scanned repeatedly at different angles on a DEDL-CT and PCD-CT. Two small lesions (~2 mm thickness; containing muscle and fat, respectively) were attached to the structure of 4 valves, placed inside the thoracic phantom, with and without an extension ring, and scanned again. Acquisition parameters were matched for the 2 CT systems and used for all scans. Metallic valves were scanned again with parameters adapted for tungsten K-edge imaging. For all valves, different metallic parts were measured on conventional images to assess their thickness and blooming artifacts. In addition, 6 parallelepipeds per metallic valve were drawn, and all voxels with density <3 times the standard deviation of the contrast media were recorded as an estimate of streak artifacts. For subjective analysis, 3 expert readers assessed conventional images of the valves, with and without lesions, and tungsten K-edge images. Conspicuity and sharpness of the different parts of the valve, the lesions, metallic, and blooming artifacts were scored on a 4-point scale. Measurements and scores were compared with the paired t test or Wilcoxon test. RESULTS The objective analysis showed that, with PCD-CT, valvular metallic structures were thinner and presented less blooming artifacts. Metallic artifacts were also reduced with PCD-CT (11 [interquartile (IQ) = 6] vs 40 [IQ = 13] % of voxels). Subjective analysis allowed noticing that some structures were visible or clearly visible only with PCD-CT. In addition, PCD-CT yielded better scores for the conspicuity and for the sharpness of all structures (all P s < 0.006), except for the conspicuity of the leaflets of the mechanical valves, which were well visible with either technique (4 [IQ = 3] for both). Both blooming and streak artifacts were reduced with PCD-CT ( P ≤ 0.01). Overall, the use of PCD-CT resulted in better conspicuity and sharpness of the lesions compared with DEDL-CT (both P s < 0.02). In addition, only with PCD-CT some differences between the 2 lesions were detectable. Adding the extension ring resulted in reduced conspicuity and sharpness with DEDL-CT ( P = 0.04 and P = 0.02, respectively) and only in reduced sharpness with PCD-CT ( P = 0.04). Tungsten K-edge imaging allowed for the visualization of the only dense structure containing it, the leaflets, and it resulted in images judged having less blooming and metallic artifacts as compared with conventional PCD-CT images ( P < 0.01). CONCLUSIONS With PCD-CT, objective and subjective image quality of metallic and biological PHVs is improved compared with DEDL-CT. Notwithstanding the improvements in image quality, millimetric lesions attached to the structure of the valves remain a challenge for PCD-CT. Tungsten K-edge imaging allows for even further reduction of artifacts.
Collapse
Affiliation(s)
- Sara Boccalini
- From the University of Lyon, INSA-Lyon, University Claude Bernard Lyon 1, Villeurbanne, France (S.B., F.D.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France (S.B., C.M., S.S.-M., L.B., P.D.); University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, Villeurbanne, France (H.L., S.S.-M., L.B., P.D.); Philips Healthcare, Suresnes, France (M.V.); Department of Cardiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France (F.D.); Department of Radiology and Nuclear Medicine, Erasmus Medical Center, Rotterdam, the Netherlands (R.B.); and Department of Cardiac Surgery, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France (M.P.)
| | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Meloni A, Maffei E, Clemente A, De Gori C, Occhipinti M, Positano V, Berti S, La Grutta L, Saba L, Cau R, Bossone E, Mantini C, Cavaliere C, Punzo B, Celi S, Cademartiri F. Spectral Photon-Counting Computed Tomography: Technical Principles and Applications in the Assessment of Cardiovascular Diseases. J Clin Med 2024; 13:2359. [PMID: 38673632 PMCID: PMC11051476 DOI: 10.3390/jcm13082359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2024] [Revised: 04/15/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
Spectral Photon-Counting Computed Tomography (SPCCT) represents a groundbreaking advancement in X-ray imaging technology. The core innovation of SPCCT lies in its photon-counting detectors, which can count the exact number of incoming x-ray photons and individually measure their energy. The first part of this review summarizes the key elements of SPCCT technology, such as energy binning, energy weighting, and material decomposition. Its energy-discriminating ability represents the key to the increase in the contrast between different tissues, the elimination of the electronic noise, and the correction of beam-hardening artifacts. Material decomposition provides valuable insights into specific elements' composition, concentration, and distribution. The capability of SPCCT to operate in three or more energy regimes allows for the differentiation of several contrast agents, facilitating quantitative assessments of elements with specific energy thresholds within the diagnostic energy range. The second part of this review provides a brief overview of the applications of SPCCT in the assessment of various cardiovascular disease processes. SPCCT can support the study of myocardial blood perfusion and enable enhanced tissue characterization and the identification of contrast agents, in a manner that was previously unattainable.
Collapse
Affiliation(s)
- Antonella Meloni
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.)
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Erica Maffei
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Alberto Clemente
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Carmelo De Gori
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Mariaelena Occhipinti
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Vicenzo Positano
- Bioengineering Unit, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.)
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| | - Sergio Berti
- Diagnostic and Interventional Cardiology Department, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Ludovico La Grutta
- Department of Radiology, University Hospital “P. Giaccone”, 90127 Palermo, Italy;
| | - Luca Saba
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato (CA), Italy; (L.S.); (R.C.)
| | - Riccardo Cau
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato (CA), Italy; (L.S.); (R.C.)
| | - Eduardo Bossone
- Department of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy;
| | - Cesare Mantini
- Department of Radiology, “G. D’Annunzio” University, 66100 Chieti, Italy;
| | - Carlo Cavaliere
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Bruna Punzo
- Department of Radiology, Istituto di Ricovero e Cura a Carattere Scientifico SYNLAB SDN, 80131 Naples, Italy; (E.M.); (C.C.); (B.P.)
| | - Simona Celi
- BioCardioLab, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Filippo Cademartiri
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.C.); (C.D.G.); (M.O.)
| |
Collapse
|
3
|
Hartung V, Gruschwitz P, Huflage H, Augustin AM, Kleefeldt F, Peter D, Lichthardt S, Ergün S, Bley TA, Grunz JP, Petritsch B. Photon-Counting Detector CT for Femoral Stent Imaging in an Extracorporeally Perfused Human Cadaveric Model. Invest Radiol 2024; 59:320-327. [PMID: 37812470 DOI: 10.1097/rli.0000000000001019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2023]
Abstract
BACKGROUND AND AIMS This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff. METHODS Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty. Radiation dose-equivalent CT angiographies (high-/medium-/low-dose: 10/5/3 mGy) with constant tube voltage of 120 kVp, matching iterative reconstruction algorithm levels, and convolution kernels were used both with PCD-CT and EID-CT. In-stent lumen visibility, luminal and in-stent attenuation as well as contrast-to-noise ratio (CNR) were assessed via region of interest and diameter measurements. Results were compared using analyses of variance and regression analyses. RESULTS Maximum in-stent lumen visibility achieved with PCD-CT was 94.48% ± 2.62%. The PCD-CT protocol with the lowest lumen visibility (BV40: 78.93% ± 4.67%) performed equal to the EID-CT protocol with the best lumen visibility (BV59: 79.49% ± 2.64%, P > 0.999). Photon-counting detector CT yielded superior CNR compared with EID-CT regardless of kernel and dose level ( P < 0.001). Maximum CNR was 48.8 ± 17.4 in PCD-CT versus 31.28 ± 5.7 in EID-CT (both BV40, high-dose). The theoretical dose reduction potential of PCD-CT over EID-CT was established at 88% (BV40), 83% (BV48/49), and 73% (BV59/60), respectively. In-stent attenuation was not significantly different from luminal attenuation outside stents in any protocol. CONCLUSIONS With superior lumen visibility and CNR, PCD-CT allowed for noticeable dose reduction over EID-CT while maintaining image quality in a continuously perfused human cadaveric model.
Collapse
Affiliation(s)
- Viktor Hartung
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Würzburg, Germany (V.H., P.G., H.H., A.M.A., T.A.B., J.-P.G., B.M.W.P.); Institute of Anatomy and Cell Biology, Julius-Maximilians University Würzburg, Würzburg, Germany (F.K., S.E.); and Department of General, Visceral, Transplant, Vascular, and Pediatric Surgery, Center of Operative Medicine, University Hospital of Würzburg, Würzburg, Germany (D.P., S.L.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
van der Bie J, Bos D, Dijkshoorn ML, Booij R, Budde RPJ, van Straten M. Thin slice photon-counting CT coronary angiography compared to conventional CT: Objective image quality and clinical radiation dose assessment. Med Phys 2024; 51:2924-2932. [PMID: 38358113 DOI: 10.1002/mp.16992] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 01/30/2024] [Accepted: 02/02/2024] [Indexed: 02/16/2024] Open
Abstract
BACKGROUND Photon-counting CT (PCCT) is the next-generation CT scanner that enables improved spatial resolution and spectral imaging. For full spectral processing, higher tube voltages compared to conventional CT are necessary to achieve the required spectral separation. This generated interest in the potential influence of thin slice high tube voltage PCCT on overall image quality and consequently on radiation dose. PURPOSE This study first evaluated tube voltages and radiation doses applied in patients who underwent coronary CT angiography with PCCT and energy-integrating detector CT (EID-CT). Next, image quality of PCCT and EID-CT was objectively evaluated in a phantom study simulating different patient sizes at these tube voltages and radiation doses. METHODS We conducted a retrospective analysis of clinical doses of patients scanned on a conventional and PCCT system. Average patient water equivalent diameters for different tube voltages were extracted from the dose reports for both EID-CT and PCCT. A conical phantom made of polyethylene with multiple diameters (26/31/36 cm) representing different patient sizes and containing an iodine insert was scanned with a EID-CT scanner using tube voltages and phantom diameters that match the patient scans and characteristics. Next, phantom scans were made with PCCT at a fixed tube voltage of 120 kV and with CTDIVOL values and phantom diameters identical to the EID-CT scans. Clinical image reconstructions at 0.6 mm slice thickness for conventional CT were compared to PCCT images with 0.4 mm slice thickness. Image quality was quantified using the detectability index (d'), which estimated the visibility of a 3 mm diameter contrast-enhanced coronary artery by considering noise, contrast, resolution, and human visual perception. Alongside d', noise, contrast and resolution were also individually assessed. In addition, the influence of various kernels (Bv40/Bv44/Bv48/Bv56), quantum iterative reconstruction strengths (QIR, 3/4) and monoenergetic levels (40/45/50/55 keV) for PCCT on d' was investigated. RESULTS In this study, 143 patients were included: 47 were scanned on PCCT (120 kV) and the remaining on EID-CT (74 small-sized at 70 kV, 18 medium-sized at 80 kV and four large-sized at 90 kV). EID-CT showed 7%-17% higher d' than PCCT with Bv40 kernel and strength four for small/medium patients. Lower monoenergetic images (40 keV) helped mitigate the difference to 1%-6%. For large patients, PCCT's detectability was up to 31% higher than EID-CT. PCCT has thinner slices but similar noise levels for similar reconstruction parameters. The noise increased with lower keV levels in PCCT (≈30% increase), but higher QIR strengths reduced noise. PCCT's iodine contrast was stable across patient sizes, while EID-CT had 33% less contrast in large patients than in small-sized patients. CONCLUSION At 120 kV, thin slice PCCT enables CCTA in phantom scans representing large patients without raising radiation dose or affecting vessel detectability. However, higher doses are needed for small and medium-sized patients to obtain a similar image quality as in EID-CT. The alternative of using lower mono-energetic levels requires further evaluation in clinical practice.
Collapse
Affiliation(s)
- Judith van der Bie
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Daniel Bos
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
- Department of Epidemiology, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Marcel L Dijkshoorn
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Ronald Booij
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| | - Marcel van Straten
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, The Netherlands
| |
Collapse
|
5
|
Elias Michael A, Schoenbeck D, Michael Woeltjen M, Boriesosdick J, Henning Niehoff J, Surov A, Borggrefe J, Schmidt B, Panknin C, Hickethier T, Maintz D, Christian Bunck A, Johannes Gertz R, Robert Kroeger J. Photon counting computed tomography of in-stent-stenosis in a phantom: Optimal virtual monoenergetic imaging in ultra high resolution. Heliyon 2024; 10:e27636. [PMID: 38509988 PMCID: PMC10950599 DOI: 10.1016/j.heliyon.2024.e27636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2024] [Revised: 02/12/2024] [Accepted: 03/04/2024] [Indexed: 03/22/2024] Open
Abstract
Rationale and objectives Coronary computed tomography angiography (CCTA) is becoming increasingly important for the diagnostic workup of coronary artery disease, nevertheless, imaging of in-stent stenosis remains challenging. For the first time, spectral imaging in Ultra High Resolution (UHR) is now possible in clinically available photon counting CT. The aim of this work is to determine the optimal virtual monoenergetic image (VMI) for imaging in-stent stenoses in cardiac stents. Materials and methods 6 stents with inserted hypodense stenoses were scanned in an established phantom in UHR mode. Images were reconstructed with 3 different kernels for spectral data (Qr56, Qr64, Qr72) with varying levels of sharpness. Based on region of interest (ROI) measurements image quality parameters including contrast-to-noise ratio (CNR) were analyzed for all available VMI (40 keV-190 keV). Finally, based on quantitative results and VMI used in clinical routine, a set of VMI was included in a qualitative reading. Results CNR showed significant variations across different keV levels (p < 0.001). Due to reduced noise there was a focal maximum in the VMI around 65 keV. The peak values were observed for kernel Qr56 at 116 keV with 19.47 ± 8.67, for kernel Qr64 at 114 keV with 13.56 ± 6.58, and for kernel Qr72 at 106 keV with 12.19 ± 3.25. However, in the qualitative evaluation the VMI with lower keV (55 keV) performed best. Conclusions Based on these experimental results, a photon counting CCTA in UHR with stents should be reconstructed with the Qr72 kernel for the assessment of in-stent stenoses, and a VMI 55 keV should be computed for the evaluation.
Collapse
Affiliation(s)
- Arwed Elias Michael
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Denise Schoenbeck
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Matthias Michael Woeltjen
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Jan Boriesosdick
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Julius Henning Niehoff
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Alexey Surov
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| | | | | | - Tilman Hickethier
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Alexander Christian Bunck
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Roman Johannes Gertz
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Jan Robert Kroeger
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany
| |
Collapse
|
6
|
Vattay B, Boussoussou M, Vecsey-Nagy M, Kolossváry M, Juhász D, Kerkovits N, Balogh H, Nagy N, Vértes M, Kiss M, Kubovje A, Merkely B, Maurovich Horvat P, Szilveszter B. Qualitative and quantitative image quality of coronary CT angiography using photon-counting computed tomography: Standard and Ultra-high resolution protocols. Eur J Radiol 2024; 175:111426. [PMID: 38493558 DOI: 10.1016/j.ejrad.2024.111426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 02/13/2024] [Accepted: 03/11/2024] [Indexed: 03/19/2024]
Abstract
PURPOSE We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). METHOD We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. RESULTS On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 ± 4.1vs.8.3 ± 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 ± 3.9vs.3.6 ± 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. CONCLUSIONS Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.
Collapse
Affiliation(s)
- Borbála Vattay
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary
| | - Melinda Boussoussou
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary
| | - Milán Vecsey-Nagy
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary
| | - Márton Kolossváry
- Gottsegen National Cardiovascular Center, 29 Haller Utca, 1096, Budapest, Hungary; Physiological Controls Research Center, University Research and Innovation Center, Óbuda University, Bécsi Ut 96/B, 1034, Budapest, Hungary
| | - Dénes Juhász
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary
| | - Nóra Kerkovits
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Hanna Balogh
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Norbert Nagy
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Miklós Vértes
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Máté Kiss
- Siemens Healthcare GmbH, Forchheim, Germany
| | - Anikó Kubovje
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Béla Merkely
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary
| | - Pál Maurovich Horvat
- Medical Imaging Center, Semmelweis University, 1082 Budapest, Korányi Sándor Street 2., Hungary
| | - Bálint Szilveszter
- Heart and Vascular Center, Semmelweis University, 1122 Budapest, Városmajor Street 68., Hungary.
| |
Collapse
|
7
|
Tian X, Chen Y, Pan S, Lan H, Cheng L. Enhanced in-stent luminal visualization and restenosis diagnosis in coronary computed tomography angiography via coronary stent decomposition algorithm from dual-energy image. Comput Biol Med 2024; 171:108128. [PMID: 38342047 DOI: 10.1016/j.compbiomed.2024.108128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Revised: 01/17/2024] [Accepted: 02/06/2024] [Indexed: 02/13/2024]
Abstract
Stent implantation is a principal therapeutic approach for coronary artery diseases. Nonetheless, the presence of stents significantly interferes with in-stent luminal (ISL) visualization and complicates the diagnosis of in-stent restenosis (ISR), thereby increasing the risk of misdiagnoses and underdiagnoses in coronary computed tomography angiography (CCTA). Dual-energy (DE) CT could calculate the volume fraction for voxels from low- and high-energy images (LHEI) and provide information on specific three basic materials. In this study, the innovative coronary stent decomposition algorithm (CSDA) was developed from the DECT three materials decomposition (TMD), through spectral simulation to determine the scan and attenuation coefficient for the stent, and preliminary execution for an in vitro sophisticated polyether ether ketone (PEEK) 3D-printed right coronary artery (RCA) replica. Furthermore, the whole-coronary-artery replica with multi-stent implantation, the RCA replica with mimetic plaque embedded, and two patients with stent further validated the effectiveness of CSDA. Post-CSDA images manifested no weakened attenuation values, no elevated noise values, and maintained anatomical integrity in the coronary lumen. The stents were effectively removed, allowing for the ISL and ISR to be clearly visualized with a discrepancy in diameters within 10%. We believe that CSDA presents a promising solution for enhancing CCTA diagnostic accuracy post-stent implantation.
Collapse
Affiliation(s)
- Xin Tian
- Department of Medical Imaging, Jincheng People's Hospital, Jincheng, 048000, China.
| | - Yunbing Chen
- Department of Medical Imaging, Jincheng People's Hospital, Jincheng, 048000, China
| | - Sancong Pan
- Department of Cardiovascular Medicine, Jincheng People's Hospital, Jincheng, 048000, China
| | - Honglin Lan
- Department of Medical Imaging, Jincheng People's Hospital, Jincheng, 048000, China
| | - Lei Cheng
- The First Affiliated Hospital of Anhui Medical University, Hefei, 230022, China.
| |
Collapse
|
8
|
Augustin AM, Hartung V, Grunz JP, Hennes JL, Huflage H, Bley TA, Petritsch B, Gruschwitz P. Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease. Acad Radiol 2024:S1076-6332(24)00078-3. [PMID: 38403477 DOI: 10.1016/j.acra.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 01/23/2024] [Accepted: 02/05/2024] [Indexed: 02/27/2024]
Abstract
RATIONALE AND OBJECTIVES This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. RESULTS The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. CONCLUSION In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.
Collapse
Affiliation(s)
- Anne Marie Augustin
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - Viktor Hartung
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Jan-Lucca Hennes
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Bernhard Petritsch
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| | - Philipp Gruschwitz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany
| |
Collapse
|
9
|
Rajiah PS, Alkadhi H, Van Mieghem NM, Budde RPJ. Utility of Photon Counting CT in Transcatheter Structural Heart Disease Interventions. Semin Roentgenol 2024; 59:32-43. [PMID: 38388095 DOI: 10.1053/j.ro.2023.11.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 02/24/2024]
Affiliation(s)
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Nicolas M Van Mieghem
- Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus University Medical Center, Rotterdam, the Netherlands
| | - Ricardo P J Budde
- Department of Radiology & Nuclear Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands
| |
Collapse
|
10
|
Flohr T, Schmidt B, Ulzheimer S, Alkadhi H. Cardiac imaging with photon counting CT. Br J Radiol 2023; 96:20230407. [PMID: 37750856 PMCID: PMC10646663 DOI: 10.1259/bjr.20230407] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 08/17/2023] [Accepted: 08/24/2023] [Indexed: 09/27/2023] Open
Abstract
CT of the heart, in particular ECG-controlled coronary CT angiography (cCTA), has become clinical routine due to rapid technical progress with ever new generations of CT equipment. Recently, CT scanners with photon-counting detectors (PCD) have been introduced which have the potential to address some of the remaining challenges for cardiac CT, such as limited spatial resolution and lack of high-quality spectral data. In this review article, we briefly discuss the technical principles of photon-counting detector CT, and we give an overview on how the improved spatial resolution of photon-counting detector CT and the routine availability of spectral data can benefit cardiac applications. We focus on coronary artery calcium scoring, cCTA, and on the evaluation of the myocardium.
Collapse
Affiliation(s)
- Thomas Flohr
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Bernhard Schmidt
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Stefan Ulzheimer
- Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
11
|
Nagayama Y, Emoto T, Kato Y, Kidoh M, Oda S, Sakabe D, Funama Y, Nakaura T, Hayashi H, Takada S, Uchimura R, Hatemura M, Tsujita K, Hirai T. Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiography. Eur Radiol 2023; 33:8488-8500. [PMID: 37432405 DOI: 10.1007/s00330-023-09888-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 03/22/2023] [Accepted: 04/23/2023] [Indexed: 07/12/2023]
Abstract
OBJECTIVES To evaluate the effect of super-resolution deep-learning-based reconstruction (SR-DLR) on the image quality of coronary CT angiography (CCTA). METHODS Forty-one patients who underwent CCTA using a 320-row scanner were retrospectively included. Images were reconstructed with hybrid (HIR), model-based iterative reconstruction (MBIR), normal-resolution deep-learning-based reconstruction (NR-DLR), and SR-DLR algorithms. For each image series, image noise, and contrast-to-noise ratio (CNR) at the left main trunk, right coronary artery, left anterior descending artery, and left circumflex artery were quantified. Blooming artifacts from calcified plaques were measured. Image sharpness, noise magnitude, noise texture, edge smoothness, overall quality, and delineation of the coronary wall, calcified and noncalcified plaques, cardiac muscle, and valves were subjectively ranked on a 4-point scale (1, worst; 4, best). The quantitative parameters and subjective scores were compared among the four reconstructions. Task-based image quality was assessed with a physical evaluation phantom. The detectability index for the objects simulating the coronary lumen, calcified plaques, and noncalcified plaques was calculated from the noise power spectrum (NPS) and task-based transfer function (TTF). RESULTS SR-DLR yielded significantly lower image noise and blooming artifacts with higher CNR than HIR, MBIR, and NR-DLR (all p < 0.001). The best subjective scores for all the evaluation criteria were attained with SR-DLR, with significant differences from all other reconstructions (p < 0.001). In the phantom study, SR-DLR provided the highest NPS average frequency, TTF50%, and detectability for all task objects. CONCLUSION SR-DLR considerably improved the subjective and objective image qualities and object detectability of CCTA relative to HIR, MBIR, and NR-DLR algorithms. CLINICAL RELEVANCE STATEMENT The novel SR-DLR algorithm has the potential to facilitate accurate assessment of coronary artery disease on CCTA by providing excellent image quality in terms of spatial resolution, noise characteristics, and object detectability. KEY POINTS • SR-DLR designed for CCTA improved image sharpness, noise property, and delineation of cardiac structures with reduced blooming artifacts from calcified plaques relative to HIR, MBIR, and NR-DLR. • In the task-based image-quality assessments, SR-DLR yielded better spatial resolution, noise property, and detectability for objects simulating the coronary lumen, coronary calcifications, and noncalcified plaques than other reconstruction techniques. • The image reconstruction times of SR-DLR were shorter than those of MBIR, potentially serving as a novel standard-of-care reconstruction technique for CCTA performed on a 320-row CT scanner.
Collapse
Affiliation(s)
- Yasunori Nagayama
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan.
| | - Takafumi Emoto
- Department of Central Radiology, Kumamoto University Hospital, Kumamoto, Japan
| | - Yuki Kato
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Masafumi Kidoh
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Seitaro Oda
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Daisuke Sakabe
- Department of Central Radiology, Kumamoto University Hospital, Kumamoto, Japan
| | - Yoshinori Funama
- Department of Medical Radiation Sciences, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
| | - Takeshi Nakaura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Hidetaka Hayashi
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Sentaro Takada
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Ryutaro Uchimura
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| | - Masahiro Hatemura
- Department of Central Radiology, Kumamoto University Hospital, Kumamoto, Japan
| | - Kenichi Tsujita
- Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan
| | - Toshinori Hirai
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1, Honjo, Chuo-Ku, Kumamoto, 860-8556, Japan
| |
Collapse
|
12
|
Mergen V, Sartoretti T, Cundari G, Serifovic M, Higashigaito K, Allmendinger T, Schmidt B, Flohr T, Manka R, Eberhard M, Alkadhi H. The Importance of Temporal Resolution for Ultra-High-Resolution Coronary Angiography: Evidence From Photon-Counting Detector CT. Invest Radiol 2023; 58:767-774. [PMID: 37222522 DOI: 10.1097/rli.0000000000000987] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
PURPOSE The aim of this study was to assess the effect of temporal resolution on subjective and objective image quality of coronary computed tomography angiography (CCTA) in the ultra-high-resolution (UHR) mode with dual-source photon-counting detector (PCD) CT. MATERIALS AND METHODS This retrospective, institutional review board-approved study evaluated 30 patients (9 women; mean age, 80 ± 10 years) undergoing UHR CCTA with a clinical dual-source PCD-CT scanner. Images were acquired with a tube voltage of 120 kV and using a collimation of 120 × 0.2 mm. Gantry rotation time was 0.25 seconds. Each scan was reconstructed using both single-source and dual-source data resulting in an image temporal resolution of 125 milliseconds and 66 milliseconds, respectively. The average heart rate and the heart rate variability were recorded. Images were reconstructed with a slice thickness of 0.2 mm, quantum iterative reconstruction strength level 4, and using the Bv64 and Bv72 kernel for patients without and with coronary stents, respectively. For subjective image quality, 2 experienced readers rated motion artifacts and vessel delineation, or in-stent lumen visualization using 5-point discrete visual scales. For objective image quality, signal-to-noise ratio, contrast-to-noise ratio, stent blooming artifacts, and vessel and stent sharpness were quantified. RESULTS Fifteen patients had coronary stents, and 15 patients had no coronary stents. The mean heart rate and heart rate variability during data acquisition were 72 ± 10 beats per minute and 5 ± 6 beats per minute, respectively. Subjective image quality in the right coronary artery, left anterior descending, and circumflex artery was significantly superior in 66 milliseconds reconstructions compared with 125 milliseconds reconstructions for both readers (all P 's < 0.01; interreader agreement, Krippendorff α = 0.84-1.00). Subjective image quality deteriorated significantly at higher heart rates for 125 milliseconds (ρ = 0.21, P < 0.05) but not for 66 milliseconds reconstructions (ρ = 0.11, P = 0.22). No association was found between heart rate variability and image quality for both 125 milliseconds (ρ = 0.09, P = 0.33) and 66 milliseconds reconstructions (ρ = 0.13, P = 0.17), respectively. Signal-to-noise ratio and contrast-to-noise ratio were similar between 66 milliseconds and 125 milliseconds reconstructions (both P 's > 0.05), respectively. Stent blooming artifacts were significantly lower on 66 milliseconds than on 125 milliseconds reconstructions (46.7% ± 10% vs 52.9% ± 8.9%, P < 0.001). Higher sharpness was found in 66 milliseconds than in 125 milliseconds reconstructions both in native coronary arteries (left anterior descending artery: 1031 ± 265 ∆HU/mm vs 819 ± 253 ∆HU/mm, P < 0.01; right coronary artery: 884 ± 352 ∆HU/mm vs 654 ± 377 ∆HU/mm, P < 0.001) and stents (5318 ± 3874 ∆HU/mm vs 4267 ± 3521 ∆HU/mm, P < 0.001). CONCLUSIONS Coronary angiography with PCD-CT in the UHR mode profits considerably from a high temporal resolution, resulting in less motion artifacts, superior vessel delineation and in-stent lumen visualization, less stent blooming artifacts, and superior vessel and stent sharpness.
Collapse
Affiliation(s)
- Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland (V.M., T.S., G.C., M.S., K.H., R.M., M.E., H.A.); Department of Radiological, Oncological, and Anatomopathological Sciences, Sapienza University of Rome, Rome, Italy (G.C.); Siemens Healthcare GmbH, Computed Tomography, Forchheim, Germany (T.A., B.S., T.F.); and Institute of Radiology, Spitäler fmi AG, Spital Interlaken, Unterseen, Switzerland (M.E.)
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Skoog S, Sandborg M, Henriksson L, Sandstedt M, Gustafsson H, Persson A. A prospective study comparing the quality of coronary computed tomography angiography images from photon counting and energy integrating detector systems. Acta Radiol 2023; 64:2957-2966. [PMID: 37735891 DOI: 10.1177/02841851231199384] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
BACKGROUND As guidelines endorse the use of computed tomography (CT) for examining coronary artery disease (CAD), it is important to compare the advantages and disadvantages of the novel photon counting detector CT (PCD-CT) technology with the established energy integrating detector CT (EID-CT). PURPOSE To compare the image quality of coronary computed tomography angiography (CCTA) and the Agatston scores (AS) derived from EID-CT and PCD-CT. MATERIAL AND METHODS In this prospective observational study, 28 patients underwent clinical calcium score and CCTA scans on an EID-CT and a PCD-CT scanner. CCTA images were qualitatively analyzed by five observers using visual grading characteristics. The correlation and agreement of the AS were assessed using Spearman's rank correlation and Bland-Altman plots. RESULTS This qualitative analyses demonstrated a high fraction of "good" or "excellent" ratings for the image criteria in both CT systems. The sharpness of the distal lumen and image quality regarding motion artifacts were rated significantly higher for EID-CT (P < 0.05). However, the sharpness of coronary calcification was rated significantly higher for PCD-CT (P < 0.05). Spearman's rank correlation and Bland-Altman plots showed good correlation (P = 0.95) and agreement regarding the AS between EID-CT and PCD-CT. CONCLUSION Both CT systems exhibited high CCTA image quality. The sharpness of calcifications was rated significantly higher for PCD-CT. A good correlation was observed between the AS derived from the two systems.
Collapse
Affiliation(s)
- Susann Skoog
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Michael Sandborg
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Medical Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Lilian Henriksson
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Mårten Sandstedt
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Håkan Gustafsson
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Medical Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Anders Persson
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
14
|
Gruschwitz P, Hartung V, Kleefeldt F, Ergün S, Huflage H, Peter D, Hendel R, Patzer TS, Pannenbecker P, Kuhl PJ, Bley TA, Petritsch B, Grunz JP. Photon-Counting Versus Energy-Integrating Detector CT Angiography of the Lower Extremity in a Human Cadaveric Model With Continuous Extracorporeal Perfusion. Invest Radiol 2023; 58:740-745. [PMID: 37185253 DOI: 10.1097/rli.0000000000000982] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
OBJECTIVES Detailed visualization of the arterial runoff is mandatory for the assessment of peripheral arterial occlusive disease. This study aims to compare the performance of a first-generation photon-counting detector computed tomography (PCD-CT) to a third-generation energy-integrating detector CT (EID-CT). MATERIALS AND METHODS Computed tomography angiographies of 8 upper leg arterial runoffs were performed on human cadaveric models with continuous extracorporeal perfusion. For both PCD-CT and EID-CT, radiation dose-equivalent 120 kVp acquisition protocols (low-/medium-/high-dose: CTDI Vol = 3/5/10 mGy) were used. All scans were performed with standard collimation (PCD-CT: 144 × 0.4 mm; EID-CT: 96 × 0.6 mm), a pitch factor of 0.4, and a gantry rotation time of 1.0 second. Reformatting of data included the use of comparable vascular kernels (Bv 48/49), a slice thickness and increment of 1.0 mm, and a field of view of 150 × 150 mm. Eight radiologists evaluated image quality independently using a browser-based pairwise forced-choice comparison setup. Kendall concordance coefficient ( W ) was calculated to estimate interrater agreement. Signal-to-noise ratio and contrast-to-noise ratio (CNR) were compared based on 1-way analyses of variance and linear regression analysis. RESULTS Low-dose PCD-CT achieved superior signal-to-noise ratio/CNR values compared with high-dose EID-CT ( P < 0.001). Linear regression analysis suggested that an EID-CT scan with a CTDI Vol of at least 15.5 mGy was required to match the CNR value of low-dose PCD-CT. Intraluminal contrast attenuation was higher in PCD-CT than EID-CT, irrespective of dose level (415.0 ± 31.9 HU vs 329.2 ± 29.4 HU; P < 0.001). Subjective image quality of low-dose PCD-CT was considered superior to high-dose EID-CT ( P < 0.001). Interrater agreement was high ( W = 0.989). CONCLUSIONS Using cadaveric models with continuous extracorporeal perfusion allows for intraindividual image quality comparisons between PCD-CT and EID-CT on variable dose levels. With superior luminal contrast attenuation and denoising in angiographies of the peripheral arterial runoff, PCD-CT displayed potential for radiation saving of up to 83% compared with EID-CT.
Collapse
Affiliation(s)
- Philipp Gruschwitz
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Viktor Hartung
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | | | - Süleyman Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg
| | - Henner Huflage
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Dominik Peter
- Department of General, Visceral, Transplant, Vascular, and Pediatric Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Robin Hendel
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Theresa Sophie Patzer
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Pauline Pannenbecker
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Philipp Josef Kuhl
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Thorsten Alexander Bley
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Bernhard Petritsch
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| | - Jan-Peter Grunz
- From the Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg
| |
Collapse
|
15
|
Rajagopal JR, Farhadi F, Nikpanah M, Sahbaee P, Saboury B, Pritchard WF, Jones EC, Chen MY, Samei E. Impact of the confluence of cardiac motion and high spatial resolution on performance of ECG-gated imaging with an investigational photon-counting CT system: A phantom study. Phys Med 2023; 114:102683. [PMID: 37738807 PMCID: PMC10798551 DOI: 10.1016/j.ejmp.2023.102683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 08/06/2023] [Accepted: 09/11/2023] [Indexed: 09/24/2023] Open
Abstract
PURPOSE Photon-counting CT (PCCT) has higher spatial resolution that conventional EID CT which improves imaging of stationary coronary plaques and stents.. In this work, we evaluated the relationship between higher spatial resolution and motion acquisition on an investigational PCCT system. METHODS An investigational photon-counting CT scanner (Siemens CounT) with ECG gating was used to image a coronary tree phantom with models of healthy, stenotic, and stented arteries using a motion simulator. Images were acquired with matched clinical parameters at rest and 60 beats per minute. An additional set of high dose stationary images were averaged to generate a motion-free, reduced noise reference. Scans were completed at standard (0.5 mm2) and high-resolution (0.25 mm2). Motion images were reconstructed at multiple phases. Regions of interest were drawn around vessels and segmented. Percentage difference from the reference standard was evaluated for vessel diameter and circularity. Mutual information between the reference and stationary and motion datasets was used as a measure of volumetric similarity. RESULTS The stenotic vessel showed the most variation from the reference when compared to healthy or stented vessels. Compared to standard resolution, high-resolution images had lower bias for diameter (-0.012 ± 0.19% vs -0.052 ± 0.14%) and lower variability for circularity (-0.13 ± 0.138% vs -0.12 ± 0.144%). Both differences were found to be statistically significant. High-resolution images had a slightly lower mutual information (1.28) than standard resolution (1.31). CONCLUSION The higher spatial resolution enabled by photon-counting CT can be harnessed for cardiac imaging as the benefits of high spatial resolution acquisitions remain relevant in the presence of motion.
Collapse
Affiliation(s)
- Jayasai R Rajagopal
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC, 27705, USA; Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA.
| | - Faraz Farhadi
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | - Moozhan Nikpanah
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | | | - Babak Saboury
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | - William F Pritchard
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | - Elizabeth C Jones
- Radiology and Imaging Sciences, Clinical Center, National Institutes of Health, Bethesda, MD 20892, USA
| | - Marcus Y Chen
- Cardiovascular Branch, National Institute of Heart, Lung, and Blood, National Institutes of Health, Bethesda, MD 20892, USA
| | - Ehsan Samei
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, NC 27705, USA
| |
Collapse
|
16
|
Douek PC, Boccalini S, Oei EHG, Cormode DP, Pourmorteza A, Boussel L, Si-Mohamed SA, Budde RPJ. Clinical Applications of Photon-counting CT: A Review of Pioneer Studies and a Glimpse into the Future. Radiology 2023; 309:e222432. [PMID: 37787672 PMCID: PMC10623209 DOI: 10.1148/radiol.222432] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 03/24/2023] [Accepted: 04/11/2023] [Indexed: 10/04/2023]
Abstract
CT systems equipped with photon-counting detectors (PCDs), referred to as photon-counting CT (PCCT), are beginning to change imaging in several subspecialties, such as cardiac, vascular, thoracic, and musculoskeletal radiology. Evidence has been building in the literature underpinning the many advantages of PCCT for different clinical applications. These benefits derive from the distinct features of PCDs, which are made of semiconductor materials capable of converting photons directly into electric signal. PCCT advancements include, among the most important, improved spatial resolution, noise reduction, and spectral properties. PCCT spatial resolution on the order of 0.25 mm allows for the improved visualization of small structures (eg, small vessels, arterial walls, distal bronchi, and bone trabeculations) and their pathologies, as well as the identification of previously undetectable anomalies. In addition, blooming artifacts from calcifications, stents, and other dense structures are reduced. The benefits of the spectral capabilities of PCCT are broad and include reducing radiation and contrast material dose for patients. In addition, multiple types of information can be extracted from a single data set (ie, multiparametric imaging), including quantitative data often regarded as surrogates of functional information (eg, lung perfusion). PCCT also allows for a novel type of CT imaging, K-edge imaging. This technique, combined with new contrast materials specifically designed for this modality, opens the door to new applications for imaging in the future.
Collapse
Affiliation(s)
| | | | - Edwin H. G. Oei
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - David P. Cormode
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Amir Pourmorteza
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Loic Boussel
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Salim A. Si-Mohamed
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| | - Ricardo P. J. Budde
- From the University of Lyon, INSA-Lyon, Claude Bernard Lyon 1
University, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France (P.C.D., L.B.,
S.A.S.M.); Department of Cardiovascular and Thoracic Radiology, Louis Pradel
Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500 Bron, France
(P.C.D., S.B., L.B., S.A.S.M.); Claude Bernard Lyon 1 University, Villeurbanne,
France (S.B.); Department of Radiology and Nuclear Medicine, Erasmus Medical
Center, Rotterdam, the Netherlands (E.H.G.O., R.P.J.B.); Department of
Radiology, University of Pennsylvania, Philadelphia, Pa (D.P.C.); Department of
Radiology and Imaging Sciences, Emory University, Atlanta, Ga (A.P.); Department
of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga (A.P.);
and Winship Cancer Institute, Atlanta, Ga (A.P.)
| |
Collapse
|
17
|
Stein T, Taron J, Verloh N, Doppler M, Rau A, Hagar MT, Faby S, Baltas D, Westermann D, Ayx I, Schönberg SO, Nikolaou K, Schlett CL, Bamberg F, Weiss J. Photon-counting computed tomography of coronary and peripheral artery stents: a phantom study. Sci Rep 2023; 13:14806. [PMID: 37684412 PMCID: PMC10491813 DOI: 10.1038/s41598-023-41854-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 09/01/2023] [Indexed: 09/10/2023] Open
Abstract
Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0-8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3-4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.
Collapse
Affiliation(s)
- Thomas Stein
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | - Jana Taron
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Niklas Verloh
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Michael Doppler
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Alexander Rau
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Muhammad Taha Hagar
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Sebastian Faby
- Computed Tomography, Siemens Healthcare GmbH, Forchheim, Germany
| | - Dimos Baltas
- Division of Medical Physics, Department of Radiation Oncology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
- German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany
| | - Dirk Westermann
- Department of Cardiology and Angiology, Interdisciplinary Vascular Center Freiburg-Bad Krozingen, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Isabelle Ayx
- Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany
| | - Stefan O Schönberg
- Department of Radiology and Nuclear Medicine, Medical Faculty Mannheim, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital Tübingen, Tübingen, Germany
| | - Christopher L Schlett
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Fabian Bamberg
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Jakob Weiss
- Department of Diagnostic and Interventional Radiology, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| |
Collapse
|
18
|
Michael AE, Schoenbeck D, Becker-Assmann J, Niehoff JH, Flohr T, Schmidt B, Panknin C, Baer-Beck M, Hickethier T, Maintz D, Bunck AC, Borggrefe J, Wiemer M, Rudolph V, Kroeger JR. Coronary stent imaging in photon counting computed Tomography: Optimization of reconstruction kernels in a phantom. Eur J Radiol 2023; 166:110983. [PMID: 37480648 DOI: 10.1016/j.ejrad.2023.110983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 07/05/2023] [Accepted: 07/16/2023] [Indexed: 07/24/2023]
Abstract
PURPOSE Imaging stents and in-stent stenosis remains a challenge in coronary computed tomography angiography (CCTA). In comparison to conventional Computed Tomography, Photon Counting CT (PCCT) provides decisive clinical advantages, among other things by providing low dose ultra-high resolution imaging of coronary arteries. This work investigates the image quality in CCTA using clinically established kernels and those optimized for the imaging of cardiac stents in PCCT, both for in-vitro stent imaging in 400 μm standard resolution mode (SRM) and 200 μm Ultra High Resolution Mode (UHR). METHODS Based on experimental scans, vascular reconstruction kernels (Bv56, Bv64, Bv72) were optimized. In an established phantom, 10 different coronary stents with 3 mm diameter were scanned in the first clinically available PCCT. Scans were reconstructed with clinically established and optimized kernels. Four readers measured visible stent lumen, performed ROI-based density measurements and rated image quality. RESULTS Regarding the visible stent lumen, UHR is significantly superior to SRM (p < 0.001). In all levels, the optimized kernels are superior to the clinically established kernels (p < 0.001). One optimized kernel showed a significant reduction of noise compared to the clinically established kernels. Overall image quality is improved with optimized kernels. CONCLUSIONS In a phantom study PCCT UHR with optimized kernels for stent imaging significantly improves the ability to assess the in-stent lumen of small cardiac stents. We recommend using UHR with an optimized sharp vascular reconstruction kernel (Bv72uo) for imaging of cardiac stent.
Collapse
Affiliation(s)
- Arwed Elias Michael
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| | - Denise Schoenbeck
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| | - Jendrik Becker-Assmann
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| | - Julius Henning Niehoff
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| | | | | | | | | | - Tilman Hickethier
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
| | - David Maintz
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
| | - Alexander Christian Bunck
- Institute for Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
| | - Jan Borggrefe
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| | - Marcus Wiemer
- Department of Cardiology and Internal Intensive Care, Johannes Wesling University Hospital, Minden, Germany.
| | - Volker Rudolph
- Department of General and Interventional Cardiology and Angiology, HDZ NRW, Ruhr University Bochum, Bochum, Germany.
| | - Jan Robert Kroeger
- Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Hospital, Ruhr University Bochum, Bochum, Germany.
| |
Collapse
|
19
|
Meloni A, Cademartiri F, Positano V, Celi S, Berti S, Clemente A, La Grutta L, Saba L, Bossone E, Cavaliere C, Punzo B, Maffei E. Cardiovascular Applications of Photon-Counting CT Technology: A Revolutionary New Diagnostic Step. J Cardiovasc Dev Dis 2023; 10:363. [PMID: 37754792 PMCID: PMC10531582 DOI: 10.3390/jcdd10090363] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 08/16/2023] [Accepted: 08/18/2023] [Indexed: 09/28/2023] Open
Abstract
Photon-counting computed tomography (PCCT) is an emerging technology that can potentially transform clinical CT imaging. After a brief description of the PCCT technology, this review summarizes its main advantages over conventional CT: improved spatial resolution, improved signal and contrast behavior, reduced electronic noise and artifacts, decreased radiation dose, and multi-energy capability with improved material discrimination. Moreover, by providing an overview of the existing literature, this review highlights how the PCCT benefits have been harnessed to enhance and broaden the diagnostic capabilities of CT for cardiovascular applications, including the detection of coronary artery calcifications, evaluation of coronary plaque extent and composition, evaluation of coronary stents, and assessment of myocardial tissue characteristics and perfusion.
Collapse
Affiliation(s)
- Antonella Meloni
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
- Unità Operativa Complessa di Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy
| | - Filippo Cademartiri
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| | - Vicenzo Positano
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
- Unità Operativa Complessa di Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy
| | - Simona Celi
- BioCardioLab, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Sergio Berti
- Diagnostic and Interventional Cardiology Department, Fondazione G. Monasterio CNR-Regione Toscana, 54100 Massa, Italy;
| | - Alberto Clemente
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| | - Ludovico La Grutta
- Department of Radiology, University Hospital “P. Giaccone”, 90127 Palermo, Italy;
| | - Luca Saba
- Department of Radiology, University Hospital of Cagliari, 09042 Monserrato, CA, Italy;
| | - Eduardo Bossone
- Department of Cardiology, Ospedale Cardarelli, 80131 Naples, Italy;
| | - Carlo Cavaliere
- Department of Radiology, Istituto di Ricerca e Cura a Carattere Scientifico SynLab-SDN, 80131 Naples, Italy; (C.C.); (B.P.)
| | - Bruna Punzo
- Department of Radiology, Istituto di Ricerca e Cura a Carattere Scientifico SynLab-SDN, 80131 Naples, Italy; (C.C.); (B.P.)
| | - Erica Maffei
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (A.M.); (V.P.); (A.C.); (E.M.)
| |
Collapse
|
20
|
Greffier J, Si-Mohamed SA, Lacombe H, Labour J, Djabli D, Boccalini S, Varasteh M, Villien M, Yagil Y, Erhard K, Boussel L, Beregi JP, Douek PC. Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study. Eur Radiol 2023; 33:5476-5488. [PMID: 36920517 PMCID: PMC10326132 DOI: 10.1007/s00330-023-09529-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 01/09/2023] [Accepted: 02/06/2023] [Indexed: 03/16/2023]
Abstract
OBJECTIVES To evaluate the quality of virtual monochromatic images (VMIs) from spectral photon-counting CT (SPCCT) and two energy-integrating detector dual-energy CT (EID-DECT) scanners from the same manufacturer, for the coronary lumen. METHODS A 21-cm section of the Mercury v4.0 phantom was scanned using a cardiac CT protocol. VMIs from 40 to 90 keV were reconstructed using high-resolution (HR) parameters for EID-DECT and SPCCT (CB and HRB kernels at 0.67 mm slice thickness, respectively). Ultra-high-resolution (UHR) parameters were used in addition to SPCCT (detailed-2 kernel, 0.43 mm slice thickness). Noise-power-spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were computed for 2-mm-diameter lumen detection. In consensus, two radiologists analyzed the quality of the images from 8 patients who underwent coronary CTA on both CT systems. RESULTS For all keV images, fpeak, f50, and d' were higher with SPCCT. The fpeak and f50 were higher with UHR-SPCCT with greater noise and lower d' compared to those of the HR-SPCCT images. Noise magnitude was constant for all energy levels (keV) with both systems, and lower with HR images, and d' decreased as keV decreased. Subjective analysis showed greater lumen sharpness and overall quality for HR and UHR-SPCCT images using all keV, with a greater difference at low keV compared to HR-EID-DECT images. CONCLUSION HR and UHR-SPCCT images gave greater detectability of the coronary lumen for 40 to 90 keV VMIs compared to two EID-DECT systems, with benefits of higher lumen sharpness and overall quality. KEY POINTS • Compared with 2 dual-energy CT systems, spectral photon-counting CT (SPCCT) improved spatial resolution, noise texture, noise magnitude, and detectability of the coronary lumen. • Use of ultra-high-resolution parameters with SPCCT improved spatial resolution and noise texture and provided high detectability of the coronary lumen, despite an increase in noise magnitude. • In eight patients, radiologists found greater overall image quality with SPCCT for all virtual monochromatic images with a greater difference at low keV, compared with dual-energy CT systems.
Collapse
Affiliation(s)
- Joel Greffier
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Salim A Si-Mohamed
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France.
- Department of Cardiothoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500, Bron, France.
| | - Hugo Lacombe
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
| | - Joey Labour
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
| | - Djamel Djabli
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Sara Boccalini
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
- Department of Cardiothoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500, Bron, France
| | - Mohammad Varasteh
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
| | | | | | | | - Loic Boussel
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
- Department of Cardiothoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500, Bron, France
- Department of Radiology, Croix Rousse Hospital, Hospices Civils de Lyon, 103 Gd Rue de la Croix-Rousse, 69004, Lyon, France
| | - Jean-Paul Beregi
- IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, Nîmes, France
| | - Philippe C Douek
- University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69621, 7 Avenue Jean Capelle O, 69100, Villeurbanne, France
- Department of Cardiothoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 59 Boulevard Pinel, 69500, Bron, France
| |
Collapse
|
21
|
Lell M, Kachelrieß M. Computed Tomography 2.0: New Detector Technology, AI, and Other Developments. Invest Radiol 2023; 58:587-601. [PMID: 37378467 PMCID: PMC10332658 DOI: 10.1097/rli.0000000000000995] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/04/2023] [Indexed: 06/29/2023]
Abstract
ABSTRACT Computed tomography (CT) dramatically improved the capabilities of diagnostic and interventional radiology. Starting in the early 1970s, this imaging modality is still evolving, although tremendous improvements in scan speed, volume coverage, spatial and soft tissue resolution, as well as dose reduction have been achieved. Tube current modulation, automated exposure control, anatomy-based tube voltage (kV) selection, advanced x-ray beam filtration, and iterative image reconstruction techniques improved image quality and decreased radiation exposure. Cardiac imaging triggered the demand for high temporal resolution, volume acquisition, and high pitch modes with electrocardiogram synchronization. Plaque imaging in cardiac CT as well as lung and bone imaging demand for high spatial resolution. Today, we see a transition of photon-counting detectors from experimental and research prototype setups into commercially available systems integrated in patient care. Moreover, with respect to CT technology and CT image formation, artificial intelligence is increasingly used in patient positioning, protocol adjustment, and image reconstruction, but also in image preprocessing or postprocessing. The aim of this article is to give an overview of the technical specifications of up-to-date available whole-body and dedicated CT systems, as well as hardware and software innovations for CT systems in the near future.
Collapse
|
22
|
Gruschwitz P, Hartung V, Kleefeldt F, Ergün S, Lichthardt S, Huflage H, Hendel R, Kunz AS, Pannenbecker P, Kuhl PJ, Augustin AM, Bley TA, Petritsch B, Grunz JP. Standardized assessment of vascular reconstruction kernels in photon-counting CT angiographies of the leg using a continuous extracorporeal perfusion model. Sci Rep 2023; 13:12109. [PMID: 37495759 PMCID: PMC10372012 DOI: 10.1038/s41598-023-39063-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 07/19/2023] [Indexed: 07/28/2023] Open
Abstract
This study evaluated the influence of different vascular reconstruction kernels on the image quality of CT angiographies of the lower extremity runoff using a 1st-generation photon-counting-detector CT (PCD-CT) compared with dose-matched examinations on a 3rd-generation energy-integrating-detector CT (EID-CT). Inducing continuous extracorporeal perfusion in a human cadaveric model, we performed CT angiographies of eight upper leg arterial runoffs with radiation dose-equivalent 120 kVp acquisition protocols (CTDIvol 5 mGy). Reconstructions were executed with different vascular kernels, matching the individual modulation transfer functions between scanners. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were computed to assess objective image quality. Six radiologists evaluated image quality subjectively using a forced-choice pairwise comparison tool. Interrater agreement was determined by calculating Kendall's concordance coefficient (W). The intraluminal attenuation of PCD-CT images was significantly higher than of EID-CT (414.7 ± 27.3 HU vs. 329.3 ± 24.5 HU; p < 0.001). Using comparable kernels, image noise with PCD-CT was significantly lower than with EID-CT (p ≤ 0.044). Correspondingly, SNR and CNR were approximately twofold higher for PCD-CT (p < 0.001). Increasing the spatial frequency for PCD-CT reconstructions by one level resulted in similar metrics compared to EID-CT (CNRfat; EID-CT Bv49: 21.7 ± 3.7 versus PCD-CT Bv60: 21.4 ± 3.5). Overall image quality of PCD-CTA achieved ratings superior to EID-CTA irrespective of the used reconstruction kernels (best: PCD-CT Bv60; worst: EID-CT Bv40; p < 0.001). Interrater agreement was good (W = 0.78). Concluding, PCD-CT offers superior intraluminal attenuation, SNR, and CNR compared to EID-CT in angiographies of the upper leg arterial runoff. Combined with improved subjective image quality, PCD-CT facilitates the use of sharper convolution kernels and ultimately bears the potential of improved vascular structure assessability.
Collapse
Affiliation(s)
- Philipp Gruschwitz
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany.
| | - Viktor Hartung
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Florian Kleefeldt
- Institute of Anatomy and Cell Biology, University of Würzburg, Würzburg, Germany
| | - Süleyman Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg, Würzburg, Germany
| | - Sven Lichthardt
- Department of General, Visceral, Transplant, Vascular, and Pediatric Surgery, University Hospital of Würzburg, Würzburg, Germany
| | - Henner Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Robin Hendel
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Andreas Steven Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Pauline Pannenbecker
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Philipp Josef Kuhl
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Anne Marie Augustin
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Thorsten Alexander Bley
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Bernhard Petritsch
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| | - Jan-Peter Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital of Würzburg, Oberdürrbacher Str. 6, 97080, Würzburg, Germany
| |
Collapse
|
23
|
Koons EK, Thorne JE, Huber N, Chang S, Rajendran K, McCollough CH, Leng S. Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising. Med Phys 2023; 50:4173-4181. [PMID: 37069830 PMCID: PMC10524296 DOI: 10.1002/mp.16415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 03/07/2023] [Accepted: 03/30/2023] [Indexed: 04/19/2023] Open
Abstract
BACKGROUND Small coronary arteries containing stents pose a challenge in CT imaging due to metal-induced blooming artifact. High spatial resolution imaging capability is as the presence of highly attenuating materials limits noninvasive assessment of luminal patency. PURPOSE The purpose of this study was to quantify the effective lumen diameter within coronary stents using a clinical photon-counting-detector (PCD) CT in concert with a convolutional neural network (CNN) denoising algorithm, compared to an energy-integrating-detector (EID) CT system. METHODS Seven coronary stents of different materials and inner diameters between 3.43 and 4.72 mm were placed in plastic tubes of diameters 3.96-4.87 mm containing 20 mg/mL of iodine solution, mimicking stented contrast-enhanced coronary arteries. Tubes were placed parallel with or perpendicular to the scanner's z-axis in an anthropomorphic phantom emulating an average-sized patient and scanned with a clinical EID-CT and PCD-CT. EID scans were performed using our standard coronary computed tomography angiography (cCTA) protocol (120 kV, 180 quality reference mAs). PCD scans were performed using the ultra-high-resolution (UHR) mode (120 × 0.2 mm collimation) at 120 kV with tube current adjusted so that CTDIvol was matched to that of EID scans. EID images were reconstructed per our routine clinical protocol (Br40, 0.6 mm thickness), and with the sharpest available kernel (Br69). PCD images were reconstructed at a thickness of 0.6 mm and a dedicated sharp kernel (Br89) which is only possible with the PCD UHR mode. To address increased image noise introduced by the Br89 kernel, an image-based CNN denoising algorithm was applied to the PCD images of stents scanned parallel to the scanner's z-axis. Stents were segmented based on full-width half maximum thresholding and morphological operations, from which effective lumen diameter was calculated and compared to reference sizes measured with a caliper. RESULTS Substantial blooming artifacts were observed on EID Br40 images, resulting in larger stent struts and reduced lumen diameter (effective diameter underestimated by 41% and 47% for parallel and perpendicular orientations, respectively). Blooming artifacts were observed on EID Br69 images with 19% and 31% underestimation of lumen diameter compared to the caliper for parallel and perpendicular scans, respectively. Overall image quality was substantially improved on PCD, with higher spatial resolution and reduced blooming artifacts, resulting in the clearer delineation of stent struts. Effective lumen diameters were underestimated by 9% and 19% relative to the reference for parallel and perpendicular scans, respectively. CNN reduced image noise by about 50% on PCD images without impacting lumen quantification (<0.3% difference). CONCLUSION The PCD UHR mode improved in-stent lumen quantification for all seven stents as compared to EID images due to decreased blooming artifacts. Implementation of CNN denoising algorithms to PCD data substantially improved image quality.
Collapse
Affiliation(s)
- Emily K. Koons
- Department of Radiology, Mayo Clinic, Rochester, MN
- Department of Biomedical Engineering and Physiology, Mayo Clinic, Rochester, MN
| | | | - Nathan Huber
- Department of Radiology, Mayo Clinic, Rochester, MN
| | | | | | | | - Shuai Leng
- Department of Radiology, Mayo Clinic, Rochester, MN
| |
Collapse
|
24
|
Jost G, McDermott M, Gutjahr R, Nowak T, Schmidt B, Pietsch H. New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT. Invest Radiol 2023; 58:515-522. [PMID: 37068840 PMCID: PMC10259215 DOI: 10.1097/rli.0000000000000978] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2023] [Accepted: 03/01/2023] [Indexed: 04/19/2023]
Abstract
ABSTRACT The recent technological developments in photon-counting detector computed tomography (PCD-CT) and the introduction of the first commercially available clinical PCD-CT unit open up new exciting opportunities for contrast media research. With PCD-CT, the efficacy of available iodine-based contrast media improves, allowing for a reduction of iodine dosage or, on the other hand, an improvement of image quality in low contrast indications. Virtual monoenergetic image reconstructions are routinely available and enable the virtual monoenergetic image energy to be adapted to the diagnostic task.A key property of PCD-CT is the ability of spectral separation in combination with improved material decomposition. Thus, the discrimination of contrast media from intrinsic or pathological tissues and the discrimination of 2 or more contrasting elements that characterize different tissues are attractive fields for contrast media research. For these approaches, K-edge imaging in combination with high atomic number elements such as the lanthanides, tungsten, tantalum, or bismuth plays a central role.The purpose of this article is to present an overview of innovative contrast media concepts that use high atomic number elements. The emphasis is on improving contrast enhancement for cardiovascular plaque imaging, stent visualization, and exploring new approaches using 2 contrasting elements. Along with the published research, new experimental findings with a contrast medium that incorporates tungsten are included.Both the literature review and the new experimental data demonstrate the great potential and feasibility for new contrast media to significantly increase diagnostic performance and to enable new clinical fields and indications in combination with PCD-CT.
Collapse
Affiliation(s)
- Gregor Jost
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| | - Michael McDermott
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, the Netherlands
| | - Ralf Gutjahr
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | - Tristan Nowak
- Computed Tomography, Siemens Healthineers, Forchheim, Germany
| | | | - Hubertus Pietsch
- From the MR and CT Contrast Media Research, Bayer AG, Berlin, Germany
| |
Collapse
|
25
|
Flohr T, Schmidt B. Technical Basics and Clinical Benefits of Photon-Counting CT. Invest Radiol 2023; 58:441-450. [PMID: 37185302 PMCID: PMC10259209 DOI: 10.1097/rli.0000000000000980] [Citation(s) in RCA: 27] [Impact Index Per Article: 27.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 03/05/2023] [Indexed: 05/17/2023]
Abstract
ABSTRACT Novel photon-counting detector CT (PCD-CT) has the potential to address the limitations of previous CT systems, such as insufficient spatial resolution, limited accuracy in detecting small low-contrast structures, or missing routine availability of spectral information. In this review article, we explain the basic principles and potential clinical benefits of PCD-CT, with a focus on recent literature that has grown rapidly since the commercial introduction of a clinically approved PCD-CT.
Collapse
|
26
|
Zsarnóczay E, Varga-Szemes A, Emrich T, Szilveszter B, van der Werf NR, Mastrodicasa D, Maurovich-Horvat P, Willemink MJ. Characterizing the Heart and the Myocardium With Photon-Counting CT. Invest Radiol 2023; 58:505-514. [PMID: 36822653 DOI: 10.1097/rli.0000000000000956] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023]
Abstract
ABSTRACT Noninvasive cardiac imaging has rapidly evolved during the last decade owing to improvements in computed tomography (CT)-based technologies, among which we highlight the recent introduction of the first clinical photon-counting detector CT (PCD-CT) system. Multiple advantages of PCD-CT have been demonstrated, including increased spatial resolution, decreased electronic noise, and reduced radiation exposure, which may further improve diagnostics and may potentially impact existing management pathways. The benefits that can be obtained from the initial experiences with PCD-CT are promising. The implementation of this technology in cardiovascular imaging allows for the quantification of coronary calcium, myocardial extracellular volume, myocardial radiomics features, epicardial and pericoronary adipose tissue, and the qualitative assessment of coronary plaques and stents. This review aims to discuss these major applications of PCD-CT with a focus on cardiac and myocardial characterization.
Collapse
Affiliation(s)
| | - Akos Varga-Szemes
- From the Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston
| | | | | | | | | | | | | |
Collapse
|
27
|
Si-Mohamed SA, Boccalini S, Villien M, Yagil Y, Erhard K, Boussel L, Douek PC. First Experience With a Whole-Body Spectral Photon-Counting CT Clinical Prototype. Invest Radiol 2023; 58:459-471. [PMID: 36822663 PMCID: PMC10259214 DOI: 10.1097/rli.0000000000000965] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/20/2023] [Indexed: 02/25/2023]
Abstract
ABSTRACT Spectral photon-counting computed tomography (SPCCT) technology holds great promise for becoming the next generation of computed tomography (CT) systems. Its technical characteristics have many advantages over conventional CT imaging. For example, SPCCT provides better spatial resolution, greater dose efficiency for ultra-low-dose and low-dose protocols, and tissue contrast superior to that of conventional CT. In addition, SPCCT takes advantage of several known approaches in the field of spectral CT imaging, such as virtual monochromatic imaging and material decomposition imaging. In addition, SPCCT takes advantage of a new approach in this field, known as K-edge imaging, which allows specific and quantitative imaging of a heavy atom-based contrast agent. Hence, the high potential of SPCCT systems supports their ongoing investigation in clinical research settings. In this review, we propose an overview of our clinical research experience of a whole-body SPCCT clinical prototype, to give an insight into the potential benefits for clinical human imaging on image quality, diagnostic confidence, and new approaches in spectral CT imaging.
Collapse
Affiliation(s)
- Salim A. Si-Mohamed
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Sara Boccalini
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | | | | | | | - Loic Boussel
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Philippe C. Douek
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| |
Collapse
|
28
|
Verelst E, Buls N, De Mey J, Nieboer KH, Vandenbergh F, Crotty D, Deak P, Sundvall A, Holmin S, De Smet A, Provyn S, Van Gompel G. Stent appearance in a novel silicon-based photon-counting CT prototype: ex vivo phantom study in head-to-head comparison with conventional energy-integrating CT. Eur Radiol Exp 2023; 7:23. [PMID: 37097376 PMCID: PMC10130245 DOI: 10.1186/s41747-023-00333-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 02/23/2023] [Indexed: 04/26/2023] Open
Abstract
BACKGROUND In this study, stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype was compared with a conventional energy-integrating detector CT (EIDCT) system. METHODS An ex vivo phantom was created, consisting of a 2% agar-water mixture, in which human-resected and stented arteries were individually embedded. Using similar technique parameters, helical scan data was acquired using a novel prototype Si-PCCT and a conventional EIDCT system at a volumetric CT dose index (CTDIvol) of 9 mGy. Reconstructions were made at 502 and 1502 mm2 field-of-views (FOVs) using a bone kernel and adaptive statistical iterative reconstruction with 0% blending. Using a 5-point Likert scale, reader evaluations were performed on stent appearance, blooming and inter-stent visibility. Quantitative image analysis was performed on stent diameter accuracy, blooming and inter-stent distinction. Qualitative and quantitative differences between Si-PCCT and EIDCT systems were tested with a Wilcoxon signed-rank test and a paired samples t-test, respectively. Inter- and intra-reader agreement was assessed using the intraclass correlation coefficient (ICC). RESULTS Qualitatively, Si-PCCT images were rated higher than EIDCT images at 150-mm FOV, based on stent appearance (p = 0.026) and blooming (p = 0.015), with a moderate inter- (ICC = 0.50) and intra-reader (ICC = 0.60) agreement. Quantitatively, Si-PCCT yielded more accurate diameter measurements (p = 0.001), reduced blooming (p < 0.001) and improved inter-stent distinction (p < 0.001). Similar trends were observed for the images reconstructed at 50-mm FOV. CONCLUSIONS When compared to EIDCT, the improved spatial resolution of Si-PCCT yields enhanced stent appearance, more accurate diameter measurements, reduced blooming and improved inter-stent distinction. KEY POINTS • This study evaluated stent appearance in a novel silicon-based photon-counting computed tomography (Si-PCCT) prototype. • Compared to standard CT, Si-PCCT resulted in more accurate stent diameter measurements. • Si-PCCT also reduced blooming artefacts and improved inter-stent visibility.
Collapse
Affiliation(s)
- Emma Verelst
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium.
| | - Nico Buls
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Johan De Mey
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Koenraad Hans Nieboer
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium
| | - Frans Vandenbergh
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium
| | | | - Paul Deak
- GE Healthcare, Waukesha, WI, 53188, USA
| | - Albert Sundvall
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76, Stockholm, Sweden
| | - Staffan Holmin
- Department of Clinical Neuroscience, Karolinska Institutet and Department of Neuroradiology, 171 74, Stockholm, Sweden
| | - Aron De Smet
- Anatomical Research Training and Education, Vrije Universiteit Brussel, 1090, Brussels, Belgium
| | - Steven Provyn
- Anatomical Research Training and Education, Vrije Universiteit Brussel, 1090, Brussels, Belgium
| | - Gert Van Gompel
- Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZB), Laarbeeklaan 101, 1090, Brussels, Belgium
| |
Collapse
|
29
|
Decker JA, O'Doherty J, Schoepf UJ, Todoran TM, Aquino GJ, Brandt V, Baruah D, Fink N, Zsarnoczay E, Flohr T, Schmidt B, Allmendinger T, Risch F, Varga-Szemes A, Emrich T. Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility. Eur Radiol 2023; 33:2469-2477. [PMID: 36462045 DOI: 10.1007/s00330-022-09283-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 09/07/2022] [Accepted: 11/04/2022] [Indexed: 12/04/2022]
Abstract
OBJECTIVES To assess the impact of scan modes and reconstruction kernels using a novel dual-source photon-counting detector CT (PCD-CT) on lumen visibility and sharpness of different stent sizes. METHODS A phantom containing six balloon-expandable stents (2.5 to 9 mm diameter) in silicone tubing was scanned on a PCD-CT with standard (0.6 mm and 0.4 mm thicknesses) and ultra-high-resolution (0.2 mm thickness) modes. With the use of increasing contrast medium concentrations, densities of 0, 200, 400, and 600 HU were achieved. Standard-resolution scans were reconstructed using increasing sharpness kernels, using both polyenergetic quantitative soft tissue "conventional" ((Qr40c(0.6 mm), Qr40c(0.4 mm), Qr72c(0.2 mm)) and vascular (Bv) virtual monoenergetic reconstructions (Bv44m(0.4 mm), Bv60m(0.4 mm)) at 70 keV. In-stent lumen visibility, sharpness (max. ΔHU of the stent measured in profile plots), and in-stent noise (standard deviation of HU) were measured. RESULTS In-stent lumen visibility was highest for Qr72c(0.2 mm) (86.5 ± 2.8% to 88.3 ± 2.6%) and in Bv60m(0.4 mm) reconstructions (77.3 ± 2.9 to 82.7 ± 2.5%). Lumen visibility was lowest in the smallest stent (2.5 mm) ranging from 54.1% in Qr40c(0.6 mm) to 74.1% in Qr72c(0.2 mm) and highest in the largest stent (9 mm) ranging from 93.8% in Qr40c(0.6 mm) to 99.1% in the Qr72c(0.2 mm) series. Lumen visibility decreased by 2.1% for every 200-HU increase in lumen attenuation. Max. ΔHU between stents and stent lumen was highest in Qr72c(0.2 mm) (ΔHU 892 ± 504 to 1526 ± 517) and Bv60m(0.4 mm) series (ΔHU 480 ± 357 to 1030 ± 344). Improvement of lumen visibility and sharpness in UHR and Bv60m(0.4 mm) series was strongest in smaller stent sizes. CONCLUSION UHR acquisition mode and sharp reconstruction kernels on a novel PCD-CT system significantly improve in-stent lumen visibility and sharpness-especially for smaller stent sizes. KEY POINTS • In-stent lumen visibility and sharpness of stents significantly improve using sharp reconstruction kernels (Bv60) and ultra-high-resolution mode in photon-counting detector computed tomography. • The observed improvement of stent-lumen visibility was highest in smaller stent sizes.
Collapse
Affiliation(s)
- Josua A Decker
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
| | - Jim O'Doherty
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Siemens Medical Solutions, Malvern, PA, USA
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.
| | - Thomas M Todoran
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, USA
| | - Gilberto J Aquino
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Verena Brandt
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Cardiology and Angiology, Robert-Bosch Hospital, Stuttgart, Germany
| | - Dhiraj Baruah
- Division of Thoracic Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC, USA
| | - Nicola Fink
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Medical Imaging Centre, Semmelweis University, Budapest, Hungary
| | | | | | | | - Franka Risch
- Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
| | - Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC, USA.,Department of Diagnostic and Interventional Radiology, University Medical Center Mainz, Mainz, Germany.,German Center for Cardiovascular Research (DZHK), Partner Site Rhine-Main, Mainz, Germany
| |
Collapse
|
30
|
Photon-Counting Computed Tomography (PCCT): Technical Background and Cardio-Vascular Applications. Diagnostics (Basel) 2023; 13:diagnostics13040645. [PMID: 36832139 PMCID: PMC9955798 DOI: 10.3390/diagnostics13040645] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Revised: 01/28/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023] Open
Abstract
Photon-counting computed tomography (PCCT) is a new advanced imaging technique that is going to transform the standard clinical use of computed tomography (CT) imaging. Photon-counting detectors resolve the number of photons and the incident X-ray energy spectrum into multiple energy bins. Compared with conventional CT technology, PCCT offers the advantages of improved spatial and contrast resolution, reduction of image noise and artifacts, reduced radiation exposure, and multi-energy/multi-parametric imaging based on the atomic properties of tissues, with the consequent possibility to use different contrast agents and improve quantitative imaging. This narrative review first briefly describes the technical principles and the benefits of photon-counting CT and then provides a synthetic outline of the current literature on its use for vascular imaging.
Collapse
|
31
|
Cosset B, Sigovan M, Boccalini S, Farhat F, Douek P, Boussel L, Si-Mohamed SA. Bicolor K-edge spectral photon-counting CT imaging for the diagnosis of thoracic endoleaks: A dynamic phantom study. Diagn Interv Imaging 2023; 104:235-242. [PMID: 36646587 DOI: 10.1016/j.diii.2022.12.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 01/16/2023]
Abstract
PURPOSE The purpose of this study was to investigate the feasibility of identifying and characterizing the three most common types of endoleaks within a thoracic aorta aneurysm model using bicolor K-edge imaging with a spectral photon-counting computing tomography (SPCCT) system in combination with a biphasic contrast agent injection. MATERIALS AND METHODS Three types of thoracic endoleaks (type 1, 2 and 3) were created in a dynamic anthropomorphic thoracic aorta phantom. Protocol consisted in an injection of an iodinated contrast material followed 80 seconds after an injection of a gadolinium-based contrast agent (GBCA). The phantom was scanned using a clinical prototype SPCCT during bicolor phase imaging consisting in an early distribution of GBCA and a late distribution of iodine. Conventional and spectral images were reconstructed for differentiating between the contrast agents and measuring their respective attenuation values and concentrations inside and outside the stent graft. RESULTS Conventional images failed to provide specific dynamic imaging contrast agents in the aneurysmal sac and outside the stent graft while spectral images differentiated their specific distribution. In type 1 and 3 thoracic endoleaks, GBCA concentration was measured outside the stent graft at 6.1 ± 3.7 (standard deviation [SD]) mg/mL and 6.0 ± 4.0 (SD) mg/mL, respectively, in favor of an early blood flow. In type 2 thoracic endoleak, iodine was measured outside the stent graft at 24.3 ± 5.5 (SD) mg/mL in favor of a late blood flow in the aneurysmal sac. CONCLUSION Bicolor K-edge imaging enabled SPCCT allows a bicolor characterization of thoracic aorta endoleaks in a single acquisition in combination with a biphasic contrast agent injection.
Collapse
Affiliation(s)
- Benoit Cosset
- Department of Cardiovascular Surgery, Hôpital Louis Pradel, Hospices Civils de Lyon, 69500 Bron, France; University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France
| | - Monica Sigovan
- University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France
| | - Sara Boccalini
- University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France; Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, 69500 Bron, France
| | - Fadi Farhat
- Department of Cardio-vascular Surgery, Infirmerie Protestante de Lyon, 69300 Caluire-et-Cuire, France
| | - Philippe Douek
- University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France; Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, 69500 Bron, France
| | - Loic Boussel
- University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France; Department of Radiology, Hôpital de la Croix Rousse, Hospices Civils de Lyon, 69500 Bron, France
| | - Salim Aymeric Si-Mohamed
- University Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, INSERM, CREATIS UMR 5220, U1206, F-69621, 69100 Villeurbanne, France; Department of Radiology, Hôpital Louis Pradel, Hospices Civils de Lyon, 69500 Bron, France.
| |
Collapse
|
32
|
Dupouy P, Pernes JM. [Contribution of coroscanner in chronic coronary syndrome]. Ann Cardiol Angeiol (Paris) 2022; 71:356-361. [PMID: 36289031 DOI: 10.1016/j.ancard.2022.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Cardiac division imaging by coroscanner has progressed a lot in 20 years to gradually become an important and potentially indispensable tool of chronic coronary cardiology. The European and American recommendations are Grade I for the assessment of symptomatic patients at intermediate to high risk, at the same level as traditional functional tests. The development of sophisticated post-treatment algorithms that apply the equations of fluid mechanics makes it possible to calculate an FFR value at any point from the CT image of the coronary artery. This FFR-CT is correctly correlated with invasive FFR compared to a threshold value of 0.80 and helps guide therapeutic choices. Thus, the coroscanner is a complement or an alternative to traditional functional tests and is positioned as a filter of access to coronary angiography, especially since it combines, from the same examination, a precise anatomical description, and a functional evaluation of the various possible lesions. Which is the Holy Grail of coronary cardiology.
Collapse
Affiliation(s)
- Patrick Dupouy
- Pôle Cardio-Vasculaire Interventionnel, Clinique les Fontaines, 54 Boulevard Aristide Briand, 77000 Melun, France.
| | - Jean Marc Pernes
- Pôle Cardio-Vasculaire Interventionnel, Clinique les Fontaines, 54 Boulevard Aristide Briand, 77000 Melun, France
| |
Collapse
|
33
|
Mergen V, Sartoretti T, Baer-Beck M, Schmidt B, Petersilka M, Wildberger JE, Euler A, Eberhard M, Alkadhi H. Ultra-High-Resolution Coronary CT Angiography With Photon-Counting Detector CT: Feasibility and Image Characterization. Invest Radiol 2022; 57:780-788. [PMID: 35640019 PMCID: PMC10184822 DOI: 10.1097/rli.0000000000000897] [Citation(s) in RCA: 70] [Impact Index Per Article: 35.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 05/11/2022] [Indexed: 12/26/2022]
Abstract
OBJECTIVES The aim of this study was to evaluate the feasibility and quality of ultra-high-resolution coronary computed tomography angiography (CCTA) with dual-source photon-counting detector CT (PCD-CT) in patients with a high coronary calcium load, including an analysis of the optimal reconstruction kernel and matrix size. MATERIALS AND METHODS In this institutional review board-approved study, 20 patients (6 women; mean age, 79 ± 10 years; mean body mass index, 25.6 ± 4.3 kg/m 2 ) undergoing PCD-CCTA in the ultra-high-resolution mode were included. Ultra-high-resolution CCTA was acquired in an electrocardiography-gated dual-source spiral mode at a tube voltage of 120 kV and collimation of 120 × 0.2 mm. The field of view (FOV) and matrix sizes were adjusted to the resolution properties of the individual reconstruction kernels using a FOV of 200 × 200 mm 2 or 150 × 150 mm 2 and a matrix size of 512 × 512 pixels or 1024 × 1024 pixels, respectively. Images were reconstructed using vascular kernels of 8 sharpness levels (Bv40, Bv44, Bv56, Bv60, Bv64, Bv72, Bv80, and Bv89), using quantum iterative reconstruction (QIR) at a strength level of 4, and a slice thickness of 0.2 mm. Images with the Bv40 kernel, QIR at a strength level of 4, and a slice thickness of 0.6 mm served as the reference. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and blooming artifacts were quantified. For subjective image quality, 2 blinded readers evaluated image noise and delineation of coronary artery plaques and the adjacent vessel lumen using a 5-point discrete visual scale. A phantom scan served to characterize image noise texture by calculating the noise power spectrum for every reconstruction kernel. RESULTS Maximum spatial frequency (f peak ) gradually shifted to higher values for reconstructions with the Bv40 to Bv64 kernel (0.15 to 0.56 mm -1 ), but not for reconstructions with the Bv72 to Bv89 kernel. Ultra-high-resolution CCTA was feasible in all patients (median calcium score, 479). In patients, reconstructions with the Bv40 kernel and a slice thickness of 0.6 mm showed largest blooming artifacts (55.2% ± 9.8%) and lowest vessel sharpness (477.1 ± 73.6 ΔHU/mm) while achieving highest SNR (27.4 ± 5.6) and CNR (32.9 ± 6.6) and lowest noise (17.1 ± 2.2 HU). Considering reconstructions with a slice thickness of 0.2 mm, image noise, SNR, CNR, vessel sharpness, and blooming artifacts significantly differed across kernels (all P 's < 0.001). With higher kernel sharpness, SNR and CNR continuously decreased, whereas image noise and vessel sharpness increased, with highest sharpness for the Bv89 kernel (2383.4 ± 787.1 ΔHU/mm). Blooming artifacts continuously decreased for reconstructions with the Bv40 (slice thickness, 0.2 mm; 52.8% ± 9.2%) to the Bv72 kernel (39.7% ± 9.1%). Subjective noise was perceived by both readers in agreement with the objective measurements. Considering delineation of coronary artery plaques and the adjacent vessel lumen, reconstructions with the Bv64 and Bv72 kernel (for both, median score of 5) were favored by the readers providing an excellent anatomic delineation of plaque characteristics and vessel lumen. CONCLUSIONS Ultra-high-resolution CCTA with PCD-CT is feasible and enables the visualization of calcified coronaries with an excellent image quality, high sharpness, and reduced blooming. Coronary plaque characterization and delineation of the adjacent vessel lumen are possible with an optimal quality using Bv64 kernel, a FOV of 200 × 200 mm 2 , and a matrix size of 512 × 512 pixels.
Collapse
Affiliation(s)
- Victor Mergen
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Thomas Sartoretti
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center
- Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands
| | | | | | | | - Joachim Ernst Wildberger
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center
- Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, the Netherlands
| | - André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
34
|
Tortora M, Gemini L, D’Iglio I, Ugga L, Spadarella G, Cuocolo R. Spectral Photon-Counting Computed Tomography: A Review on Technical Principles and Clinical Applications. J Imaging 2022; 8:jimaging8040112. [PMID: 35448239 PMCID: PMC9029331 DOI: 10.3390/jimaging8040112] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Revised: 04/11/2022] [Accepted: 04/14/2022] [Indexed: 01/01/2023] Open
Abstract
Photon-counting computed tomography (CT) is a technology that has attracted increasing interest in recent years since, thanks to new-generation detectors, it holds the promise to radically change the clinical use of CT imaging. Photon-counting detectors overcome the major limitations of conventional CT detectors by providing very high spatial resolution without electronic noise, providing a higher contrast-to-noise ratio, and optimizing spectral images. Additionally, photon-counting CT can lead to reduced radiation exposure, reconstruction of higher spatial resolution images, reduction of image artifacts, optimization of the use of contrast agents, and create new opportunities for quantitative imaging. The aim of this review is to briefly explain the technical principles of photon-counting CT and, more extensively, the potential clinical applications of this technology.
Collapse
Affiliation(s)
- Mario Tortora
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy; (M.T.); (L.G.); (I.D.); (L.U.); (G.S.)
| | - Laura Gemini
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy; (M.T.); (L.G.); (I.D.); (L.U.); (G.S.)
| | - Imma D’Iglio
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy; (M.T.); (L.G.); (I.D.); (L.U.); (G.S.)
| | - Lorenzo Ugga
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy; (M.T.); (L.G.); (I.D.); (L.U.); (G.S.)
| | - Gaia Spadarella
- Department of Advanced Biomedical Sciences, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy; (M.T.); (L.G.); (I.D.); (L.U.); (G.S.)
| | - Renato Cuocolo
- Department of Clinical Medicine and Surgery, University of Naples “Federico II”, Via Sergio Pansini 5, 80131 Naples, Italy
- Department of Medicine, Surgery and Dentistry, University of Salerno, Via Salvador Allende 43, 84081 Baronissi, Italy
- Correspondence:
| |
Collapse
|
35
|
Boccalini S, Si-Mohamed SA, Lacombe H, Diaw A, Varasteh M, Rodesch PA, Villien M, Sigovan M, Dessouky R, Coulon P, Yagil Y, Lahoud E, Erhard K, Rioufol G, Finet G, Bonnefoy-Cudraz E, Bergerot C, Boussel L, Douek PC. First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography. Invest Radiol 2022; 57:212-221. [PMID: 34711766 PMCID: PMC8903215 DOI: 10.1097/rli.0000000000000835] [Citation(s) in RCA: 60] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 08/18/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES The aim of this study is to compare the image quality of in vivo coronary stents between an energy integrating detectors dual-layer computed tomography (EID-DLCT) and a clinical prototype of spectral photon counting computed tomography (SPCCT). MATERIALS AND METHODS In January to June 2021, consecutive patients with coronary stents were prospectively enrolled to undergo a coronary computed tomography (CT) with an EID-DLCT (IQon, Philips) and an SPCCT (Philips). The study was approved by the local ethical committee and patients signed an informed consent. A retrospectively electrocardiogram-gated acquisition was performed with optimized matching parameters on the 2 scanners (EID-DLCT: collimation, 64 × 0.625 mm; kVp, 120, automatic exposure control with target current at 255 mAs; rotation time, 0.27 seconds; SPCCT: collimation, 64 × 0.275 mm; kVp, 120; mAs, 255; rotation time, 0.33 seconds). The injection protocol was the same on both scanners: 65 to 75 mL of Iomeron (Bracco) at 5 mL/s. Images were reconstructed with slice thickness of 0.67 mm, 512 matrix, XCB (Xres cardiac standard) and XCD (Xres cardiac detailed) kernel, iDose 3 for EID-DLCT and 0.25-mm slice thickness, 1024 matrix, Detailed 2 and Sharp kernel, and iDose 6 for SPCCT. Two experienced observers measured the proximal and distal external and internal diameters of the stents to quantify blooming artifacts. Regions of interest were drawn in the lumen of the stent and of the upstream coronary artery. The difference (Δ S-C) between the respective attenuation values was calculated as a quantification of stent-induced artifacts on intrastent image quality. For subjective image quality, 3 experienced observers graded with a 4-point scale the image quality of different parameters: coronary wall before the stent, stent lumen, stent structure, calcifications surrounding the stent, and beam-hardening artifacts. RESULTS Eight patients (age, 68 years [interquartile range, 8]; all men; body mass index, 26.2 kg/m2 [interquartile range, 4.2]) with 16 stents were scanned. Five stents were not evaluable owing to motion artifacts on the SPCCT. Of the remaining, all were drug eluting stents, of which 6 were platinum-chromium, 3 were cobalt-platinum-iridium, and 1 was stainless steel. For 1 stent, no information could be retrieved. Radiation dose was lower with the SPCCT (fixed CT dose index of 25.7 mGy for SPCCT vs median CT dose index of 35.7 [IQ = 13.6] mGy; P = 0.02). For 1 stent, the internal diameter was not assessable on EID-DLCT. External diameters were smaller and internal diameters were larger with SPCCT (all P < 0.05). Consequently, blooming artifacts were reduced on SPCCT (P < 0.05). Whereas Hounsfield unit values within the coronary arteries on the 2 scanners were similar, the Δ S-C was lower for SPCCT-Sharp as compared with EID-DLCT-XCD and SPCCT-Detailed 2 (P < 0.05). The SPCCT received higher subjective scores than EID-DLCT for stent lumen, stent structure, surrounding calcifications and beam-hardening for both Detailed 2 and Sharp (all P ≤ 0.05). The SPCCT-Sharp was judged better for stent structure and beam-hardening assessment as compared with SPCCT-Detailed 2. CONCLUSION Spectral photon counting CT demonstrated improved objective and subjective image quality as compared with EID-DLCT for the evaluation of coronary stents even with a reduced radiation dose.
Collapse
Affiliation(s)
- Sara Boccalini
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Salim A. Si-Mohamed
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Hugo Lacombe
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
| | - Adja Diaw
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
| | - Mohammad Varasteh
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
| | - Pierre-Antoine Rodesch
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
| | | | - Monica Sigovan
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
| | - Riham Dessouky
- Department of Radiology, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | | | | | | | | | - Gilles Rioufol
- Department of Cardiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Gerard Finet
- Department of Cardiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Eric Bonnefoy-Cudraz
- Department of Cardiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Cyrille Bergerot
- Department of Cardiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Loic Boussel
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| | - Philippe C. Douek
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, Villeurbanne, France
- Department of Cardiovascular and Thoracic Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France
| |
Collapse
|
36
|
Si-Mohamed SA, Boccalini S, Lacombe H, Diaw A, Varasteh M, Rodesch PA, Dessouky R, Villien M, Tatard-Leitman V, Bochaton T, Coulon P, Yagil Y, Lahoud E, Erhard K, Riche B, Bonnefoy E, Rioufol G, Finet G, Bergerot C, Boussel L, Greffier J, Douek PC. Coronary CT Angiography with Photon-counting CT: First-In-Human Results. Radiology 2022; 303:303-313. [PMID: 35166583 DOI: 10.1148/radiol.211780] [Citation(s) in RCA: 119] [Impact Index Per Article: 59.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Background Spatial resolution, soft-tissue contrast, and dose-efficient capabilities of photon-counting CT (PCCT) potentially allow a better quality and diagnostic confidence of coronary CT angiography (CCTA) in comparison to conventional CT. Purpose To compare the quality of CCTA scans obtained with a clinical prototype PCCT system and an energy-integrating detector (EID) dual-layer CT (DLCT) system. Materials and Methods In this prospective board-approved study with informed consent, participants with coronary artery disease underwent retrospective electrocardiographically gated CCTA with both systems after injection of 65-75 mL of 400 mg/mL iodinated contrast agent at 5 mL/sec. A prior phantom task-based quality assessment of the detectability index of coronary lesions was performed. Ultra-high-resolution parameters were used for PCCT (1024 matrix, 0.25-mm section thickness) and EID DLCT (512 matrix, 0.67-mm section thickness). Three cardiac radiologists independently performed a blinded analysis using a five-point quality score (1 = insufficient, 5 = excellent) for overall image quality, diagnostic confidence, and diagnostic quality of calcifications, stents, and noncalcified plaques. A logistic regression model, adjusted for radiologists, was used to evaluate the proportion of improvement in scores with the best method. Results Fourteen consecutive participants (12 men; mean age, 61 years ± 17) were enrolled. Scores of overall quality and diagnostic confidence were higher with PCCT images with a median of 5 (interquartile range [IQR], 2) and 5 (IQR, 1) versus 4 (IQR, 1) and 4 (IQR, 3) with EID DLCT images, using a mean tube current of 255 mAs ± 0 versus 349 mAs ± 111 for EID DLCT images (P < .01). Proportions of improvement with PCCT images for quality of calcification, stent, and noncalcified plaque were 100%, 92% (95% CI: 71, 98), and 45% (95% CI: 28, 63), respectively. In the phantom study, detectability indexes were 2.3-fold higher for lumen and 2.9-fold higher for noncalcified plaques with PCCT images. Conclusion Coronary CT angiography with a photon-counting CT system demonstrated in humans an improved image quality and diagnostic confidence compared with an energy-integrating dual-layer CT. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sandfort and Bluemke in this issue.
Collapse
Affiliation(s)
- Salim A Si-Mohamed
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Sara Boccalini
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Hugo Lacombe
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Adja Diaw
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Mohammad Varasteh
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Pierre-Antoine Rodesch
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Riham Dessouky
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Marjorie Villien
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Valérie Tatard-Leitman
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Thomas Bochaton
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Philippe Coulon
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Yoad Yagil
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Elias Lahoud
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Klaus Erhard
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Benjamin Riche
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Eric Bonnefoy
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Gilles Rioufol
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Gerard Finet
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Cyrille Bergerot
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Loic Boussel
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Joel Greffier
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| | - Philippe C Douek
- From the University Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Villeurbanne, France (S.A.S.M., S.B., H.L., A.D., M. Varasteh, P.A.R., V.T.L., L.B., P.C.D.); Departments of Radiology (S.A.S.M., S.B., L.B., P.C.D.) and Cardiology (T.B., E.B., G.R., G.F., C.B.), Louis Pradel Hospital, Hospices Civils de Lyon, Bron, France; Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); Philips Healthcare, Suresnes, France (M Villien, P.C.); Philips Healthcare, Haifa, Israel (Y.Y., E.L.); Philips Healthcare, Hamburg, Germany (K.E.); Public Health Center, Department of Biostatistics and Bioinformatics, Hospices Civils de Lyon, Lyon, France (B.R.); Department of Biometrics and Evolutionary Biology Laboratory, Biostatistics-Health Team, CNRS, UMR 5558, Villeurbanne, France (B.R.); and Department of Medical Imaging, CHU Nimes, University Montpellier, Nimes Medical Imaging Group, EA 2992, Montpellier, France (J.G.)
| |
Collapse
|
37
|
Rotzinger DC, Racine D, Becce F, Lahoud E, Erhard K, Si-Mohamed SA, Greffier J, Viry A, Boussel L, Meuli RA, Yagil Y, Monnin P, Douek PC. Performance of Spectral Photon-Counting Coronary CT Angiography and Comparison with Energy-Integrating-Detector CT: Objective Assessment with Model Observer. Diagnostics (Basel) 2021; 11:2376. [PMID: 34943611 PMCID: PMC8700425 DOI: 10.3390/diagnostics11122376] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/02/2021] [Accepted: 12/14/2021] [Indexed: 11/16/2022] Open
Abstract
AIMS To evaluate spectral photon-counting CT's (SPCCT) objective image quality characteristics in vitro, compared with standard-of-care energy-integrating-detector (EID) CT. METHODS We scanned a thorax phantom with a coronary artery module at 10 mGy on a prototype SPCCT and a clinical dual-layer EID-CT under various conditions of simulated patient size (small, medium, and large). We used filtered back-projection with a soft-tissue kernel. We assessed noise and contrast-dependent spatial resolution with noise power spectra (NPS) and target transfer functions (TTF), respectively. Detectability indices (d') of simulated non-calcified and lipid-rich atherosclerotic plaques were computed using the non-pre-whitening with eye filter model observer. RESULTS SPCCT provided lower noise magnitude (9-38% lower NPS amplitude) and higher noise frequency peaks (sharper noise texture). Furthermore, SPCCT provided consistently higher spatial resolution (30-33% better TTF10). In the detectability analysis, SPCCT outperformed EID-CT in all investigated conditions, providing superior d'. SPCCT reached almost perfect detectability (AUC ≈ 95%) for simulated 0.5-mm-thick non-calcified plaques (for large-sized patients), whereas EID-CT had lower d' (AUC ≈ 75%). For lipid-rich atherosclerotic plaques, SPCCT achieved 85% AUC vs. 77.5% with EID-CT. CONCLUSIONS SPCCT outperformed EID-CT in detecting simulated coronary atherosclerosis and might enhance diagnostic accuracy by providing lower noise magnitude, markedly improved spatial resolution, and superior lipid core detectability.
Collapse
Affiliation(s)
- David C. Rotzinger
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Rue du Bugnon 46, CH 1011 Lausanne, Switzerland; (F.B.); (R.A.M.)
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
| | - Damien Racine
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
- Institute of Radiation Physics, Lausanne University Hospital (CHUV), CH 1007 Lausanne, Switzerland
| | - Fabio Becce
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Rue du Bugnon 46, CH 1011 Lausanne, Switzerland; (F.B.); (R.A.M.)
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
| | - Elias Lahoud
- CT/AMI Research and Development, Philips Medical Systems, Haifa 31004, Israel; (E.L.); (Y.Y.)
| | - Klaus Erhard
- Philips GmbH Innovative Technologies, Philips Research Laboratories, 22335 Hamburg, Germany;
| | - Salim A. Si-Mohamed
- Radiology Department, Hospices Civils de Lyon, 69500 Lyon, France; (S.A.S.-M.); (L.B.); (P.C.D.)
- Faculté de Médecine Lyon Est, Université Claude Bernard Lyon 1, CREATIS, CNRS UMR 5220, INSERM U1206, INSA-Lyon, 69100 Lyon, France
| | - Joël Greffier
- Department of Medical Imaging, CHU Nimes, University of Montpellier, 30900 Nimes, France;
| | - Anaïs Viry
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
- Institute of Radiation Physics, Lausanne University Hospital (CHUV), CH 1007 Lausanne, Switzerland
| | - Loïc Boussel
- Radiology Department, Hospices Civils de Lyon, 69500 Lyon, France; (S.A.S.-M.); (L.B.); (P.C.D.)
- Faculté de Médecine Lyon Est, Université Claude Bernard Lyon 1, CREATIS, CNRS UMR 5220, INSERM U1206, INSA-Lyon, 69100 Lyon, France
| | - Reto A. Meuli
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital (CHUV), Rue du Bugnon 46, CH 1011 Lausanne, Switzerland; (F.B.); (R.A.M.)
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
| | - Yoad Yagil
- CT/AMI Research and Development, Philips Medical Systems, Haifa 31004, Israel; (E.L.); (Y.Y.)
| | - Pascal Monnin
- Faculty of Biology and Medicine (FBM), University of Lausanne (UNIL), CH 1015 Lausanne, Switzerland; (D.R.); (A.V.); (P.M.)
- Institute of Radiation Physics, Lausanne University Hospital (CHUV), CH 1007 Lausanne, Switzerland
| | - Philippe C. Douek
- Radiology Department, Hospices Civils de Lyon, 69500 Lyon, France; (S.A.S.-M.); (L.B.); (P.C.D.)
- Faculté de Médecine Lyon Est, Université Claude Bernard Lyon 1, CREATIS, CNRS UMR 5220, INSERM U1206, INSA-Lyon, 69100 Lyon, France
| |
Collapse
|
38
|
Spectral Photon-Counting CT Technology in Chest Imaging. J Clin Med 2021; 10:jcm10245757. [PMID: 34945053 PMCID: PMC8704215 DOI: 10.3390/jcm10245757] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 11/30/2021] [Accepted: 12/02/2021] [Indexed: 12/17/2022] Open
Abstract
The X-ray imaging field is currently undergoing a period of rapid technological innovation in diagnostic imaging equipment. An important recent development is the advent of new X-ray detectors, i.e., photon-counting detectors (PCD), which have been introduced in recent clinical prototype systems, called PCD computed tomography (PCD-CT) or photon-counting CT (PCCT) or spectral photon-counting CT (SPCCT) systems. PCD allows a pixel up to 200 microns pixels at iso-center, which is much smaller than that can be obtained with conventional energy integrating detectors (EID). PCDs have also a higher dose efficiency than EID mainly because of electronic noise suppression. In addition, the energy-resolving capabilities of these detectors allow generating spectral basis imaging, such as the mono-energetic images or the water/iodine material images as well as the K-edge imaging of a contrast agent based on atoms of high atomic number. In recent years, studies have therefore been conducted to determine the potential of PCD-CT as an alternative to conventional CT for chest imaging.
Collapse
|
39
|
Euler A, Nowak T, Bucher B, Eberhard M, Schmidt B, Flohr TG, Frey D, Distler O, Alkadhi H. Assessment of Bone Mineral Density From a Computed Tomography Topogram of Photon-Counting Detector Computed Tomography-Effect of Phantom Size and Tube Voltage. Invest Radiol 2021; 56:614-620. [PMID: 33787538 DOI: 10.1097/rli.0000000000000781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE The aim of this study was to assess the accuracy and impact of different sizes and tube voltages on bone mineral density (BMD) assessment using a computed tomography (CT) topogram acquired with photon-counting detector CT in an osteopenic ex vivo animal spine. MATERIALS AND METHODS The lumbar back of a piglet was used to simulate osteopenia of the lumbar spine. Five fat layers (each with a thickness of 3 cm) were consecutively placed on top of the excised spine to emulate a total of 5 different sizes. Each size was repeatedly imaged on (A) a conventional dual-energy x-ray absorptiometry scanner as the reference standard, (B) a prototype photon-counting detector CT system at 120 kVp with energy thresholds at 20 and 70 keV, and (C) the same prototype system at 140 kVp with thresholds at 20 and 75 keV. Material-specific data were reconstructed from spectral topograms for B and C. Bone mineral density was measured for 3 lumbar vertebrae (L2-L4). A linear mixed-effects model was used to estimate the impact of vertebra, imaging setup, size, and their interaction term on BMD. RESULTS The BMD of the lumbar spine corresponded to a T score in humans between -4.2 and -4.8, which is seen in osteoporosis. Averaged across the 3 vertebrae and 5 sizes, mean BMD was 0.56 ± 0.03, 0.55 ± 0.02, and 0.55 ± 0.02 g/cm2 for setup A, B, and C, respectively. There was no significant influence of imaging setup (P = 0.7), simulated size (P = 0.67), and their interaction term (both P > 0.2) on BMD. Bone mineral density decreased significantly from L2 to L4 for all 3 setups (all P < 0.0001). Bone mineral density was 0.59 ± 0.01, 0.57 ± 0.01, and 0.52 ± 0.02 g/cm2 for L2, L3, and L4, respectively, for setup A; 0.57 ± 0.02, 0.55 ± 0.01, and 0.53 ± 0.01 g/cm2 for setup B; and 0.57 ± 0.01, 0.55 ± 0.01, and 0.53 ± 0.01 g/cm2 for setup C. CONCLUSION A single CT topogram acquired on photon-counting detector CT with 2 energy thresholds enabled BMD quantification with similar accuracy compared with dual-energy x-ray absorptiometry over a range of simulated sizes and tube voltages in an osteopenic ex vivo animal spine.
Collapse
Affiliation(s)
- André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | - Diana Frey
- Department of Rheumatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Oliver Distler
- Department of Rheumatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
40
|
Rajagopal JR, Farhadi F, Richards T, Nikpanah M, Sahbaee P, Shanbhag SM, Bandettini WP, Saboury B, Malayeri AA, Pritchard WF, Jones EC, Samei E, Chen MY. Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT. Radiol Cardiothorac Imaging 2021; 3:e210102. [PMID: 34778782 PMCID: PMC8581588 DOI: 10.1148/ryct.2021210102] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 08/30/2021] [Accepted: 09/30/2021] [Indexed: 11/11/2022]
Abstract
PURPOSE To compare the performance of energy-integrating detector (EID) CT, photon-counting detector CT (PCCT), and high-resolution PCCT (HR-PCCT) for the visualization of coronary plaques and reduction of stent artifacts in a phantom model. MATERIALS AND METHODS An investigational scanner with EID and PCCT subsystems was used to image a coronary artery phantom containing cylindrical probes simulating different plaque compositions. The phantom was imaged with and without coronary stents using both subsystems. Images were reconstructed with a clinical cardiac kernel and an additional HR-PCCT kernel. Regions of interest were drawn around probes and evaluated for in-plane diameter and a qualitative comparison by expert readers. A linear mixed-effects model was used to compare the diameter results, and a Shrout-Fleiss intraclass correlation coefficient was used to assess consistency in the reader study. RESULTS Comparing in-plane diameter to the physical dimension for nonstented and stented phantoms, measurements of the HR-PCCT images were more accurate (nonstented: 4.4% ± 1.1 [standard deviation], stented: -9.4% ± 4.6) than EID (nonstented: 15.5% ± 4.0, stented: -19.5% ± 5.8) and PCCT (nonstented: 19.4% ± 2.5, stented: -18.3% ± 4.4). Our analysis of variance found diameter measurements to be different across image groups for both nonstented and stented cases (P < .001). HR-PCCT showed less change on average in percent stenosis due to the addition of a stent (-5.5%) than either EID (+90.5%) or PCCT (+313%). For both nonstented and stented phantoms, observers rated the HR-PCCT images as having higher plaque conspicuity and as being the image type that was least impacted by stent artifacts, with a high level of agreement (interclass correlation coefficient = 0.85). CONCLUSION Despite increased noise, HR-PCCT images were able to better visualize coronary plaques and reduce stent artifacts compared with EID or PCCT reconstructions.Keywords: CT-Spectral Imaging (Dual Energy), Phantom Studies, Cardiac, Physics, Technology Assessment© RSNA, 2021.
Collapse
Affiliation(s)
- Jayasai R Rajagopal
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Faraz Farhadi
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Taylor Richards
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Moozhan Nikpanah
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Pooyan Sahbaee
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Sujata M Shanbhag
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - W Patricia Bandettini
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Babak Saboury
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Ashkan A Malayeri
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - William F Pritchard
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Elizabeth C Jones
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Ehsan Samei
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| | - Marcus Y Chen
- Carl E. Ravin Advanced Imaging Laboratories, Medical Physics Graduate Program, Department of Radiology, Duke University Medical Center, Durham, NC (J.R.R., T.R., E.S.); Department of Radiology and Imaging Sciences, Clinical Center (F.F., M.N., B.S., A.A.M., E.C.J.), Cardiovascular Branch, National Heart, Lung, and Blood Institute (S.M.S., W.P.B., M.Y.C.), and Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center (W.F.P.), National Institutes of Health, 10 Center Dr, Building 10, Room B1D417, Bethesda, MD 20892; and Siemens Medical Solutions USA, Malvern, Pa (P.S.)
| |
Collapse
|
41
|
Petritsch B, Petri N, Weng AM, Petersilka M, Allmendinger T, Bley TA, Gassenmaier T. Photon-Counting Computed Tomography for Coronary Stent Imaging: In Vitro Evaluation of 28 Coronary Stents. Invest Radiol 2021; 56:653-660. [PMID: 33867450 DOI: 10.1097/rli.0000000000000787] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVES The aim of this study was to assess in-stent lumen visibility and quantitative image characteristics of different coronary stents using a novel photon-counting detector (PCD) computed tomography (CT) system in comparison to a state-of-the-art energy-integrating detector (EID) CT scanner. MATERIALS AND METHODS In this in vitro phantom study, 28 different coronary stents ranging from 2.25 to 4.5 mm lumen diameter were expanded into plastic tubes filled with contrast agent. Stent-containing plastic tubes were positioned in a custom-made emulsion-filled phantom, which was inserted into an anthropomorphic phantom simulating a medium-sized patient. Computed tomography scans were acquired parallel to the scanners' z axis using a novel cadmium telluride-based PCD CT system (SOMATOM CountPlus; Siemens Healthcare GmbH, Forchheim Germany), operating in 2 different modes (standard-resolution mode [SR] and ultra-high-resolution [UHR] mode), and a latest generation dual-source EID CT system (SOMATOM Force; Siemens Healthcare GmbH, Forchheim). CTDIvol-matched images were reconstructed with comparable convolution kernels and using the same reconstruction parameters. In-stent lumen visibility (in %), increase in in-stent attenuation (expressed as Δ in-stent CT attenuation), and image noise (in Hounsfield unit) were manually measured. Parts of the image analysis (in-stent lumen visibility) were additionally performed in an automated way. Differences were tested using Wilcoxon signed rank test. RESULTS The best in-stent lumen visibility was achieved with the PCD-UHR mode and the lowest noise levels with the PCD-SR mode. The median in-stent lumen visibility was significantly higher (P < 0.001) with PCD (SR, 66.7%; interquartile range [IQR], 63.3-72.3; UHR, 68.9%; IQR, 64.4-74.4) compared with EID (65.4%; IQR, 62.2-70.4). The Δ in-stent CT attenuation was significantly lower for PCD in both SR (78 HU; IQR, 46-108; P = 0.024) and UHR (85 HU; IQR, 59-113; P = 0.006) compared with EID (108 HU; IQR, 85-126). Image noise was significantly lower (P < 0.001) for PCD-SR (21 HU; IQR, 21-21) compared with EID images (25 HU; IQR, 24-25.0). CONCLUSIONS The PCD provides superior in-stent lumen visibility and quantitative image characteristics when compared with conventional EID.
Collapse
Affiliation(s)
| | - Nils Petri
- Internal Medicine I, University Hospital Würzburg, Würzburg
| | - Andreas M Weng
- From the Departments of Diagnostic and Interventional Radiology
| | | | | | - Thorsten A Bley
- From the Departments of Diagnostic and Interventional Radiology
| | | |
Collapse
|
42
|
Sartoretti T, Eberhard M, Nowak T, Gutjahr R, Jost G, Pietsch H, Schmidt B, Flohr T, Alkadhi H, Euler A. Photon-Counting Multienergy Computed Tomography With Spectrally Optimized Contrast Media for Plaque Removal and Stenosis Assessment. Invest Radiol 2021; 56:563-570. [PMID: 33660630 DOI: 10.1097/rli.0000000000000773] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The aim of this study was to systematically evaluate the potential to combine investigational contrast media with spectrally optimized energy-thresholding of photon-counting detector computed tomography (PCCT) for subtraction of calcified plaques in a coronary artery stenosis phantom. METHODS A small vessel phantom containing 3 fillable tubes (diameter, 3 mm each) with calcified plaques was placed into an anthropomorphic chest phantom. The plaques had incremental thicknesses ranging from 0.3 to 2.7 mm, simulating vessel stenoses ranging from 10% to 90% of the lumen diameter. The phantom was filled with 5 different investigational contrast media (iodine, bismuth, hafnium, holmium, and tungsten) at equal mass concentrations (15 mg/mL) and was imaged on a prototype PCCT at 140 kVp using optimized, contrast media-dependent energy thresholds. Contrast maps (CMs) were reconstructed for each contrast medium by applying a linear 2-material decomposition algorithm. Image noise magnitude and noise texture of CM were compared among the contrast media using the noise power spectrum. Two blinded readers independently rated the vessel lumen visualization on short-axis and the overall subjective image quality on long-axis CM relative to iodine as the reference standard. Four readers determined the highest degree of stenosis that could be assessed with high diagnostic confidence on long-axis CM. RESULTS Average image noise on CM was lower for tungsten (49 HU) and hafnium (62 HU) and higher for bismuth (81 HU) and holmium (165 HU) compared with iodine (78 HU). Noise texture of CM was similar among the contrast media. Interreader agreement for vessel lumen visualization on short-axis CM ranged from moderate to excellent (k = 0.567-0.814). Compared with iodine, lumen visualization of each reader was improved using tungsten (P < 0.001 for both readers), similar to improved using hafnium (P = 0.008, P = 0.29), similar using bismuth (P = 0.38, P = 0.69), and decreased using holmium (both, P < 0.001). Overall subjective image quality was similar for holmium and superior for tungsten, hafnium, and bismuth as compared with iodine. Higher-degree stenoses were evaluable with high confidence using tungsten (mean, 70%; interquartile range, 70%-70%), bismuth (70%; 60%-70%), and hafnium (75%; 70%-80%) compared with iodine (50%; 50%-60%) and holmium (50%; 50%-60%). CONCLUSIONS Spectral optimization in PCCT combined with investigational contrast media can improve calcium subtraction and stenosis assessment in small vessels. Contrast maps of tungsten and, to a lesser extent, hafnium as contrast media yielded superior image noise properties and improved vessel lumen visualization, along with a higher subjective image quality compared with the reference standard iodine.
Collapse
Affiliation(s)
- Thomas Sartoretti
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Matthias Eberhard
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | | | | | | | | | | | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - André Euler
- From the Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| |
Collapse
|
43
|
Hsieh SS, Leng S, Rajendran K, Tao S, McCollough CH. Photon Counting CT: Clinical Applications and Future Developments. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:441-452. [PMID: 34485784 PMCID: PMC8409241 DOI: 10.1109/trpms.2020.3020212] [Citation(s) in RCA: 46] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
The use of a photon counting detector in CT (PCD CT) is currently the subject of intense investigation and development. In this review article, we will describe potential clinical applications of this technology with a particular focus on the experience of our own institution with a prototype PCD CT scanner. PCDs have three primary advantages over conventional, energy integrating detectors (EIDs): they provide spectral information without need for a dedicated dual energy protocol; they are immune to electronic noise; and they can be made very high resolution without significant compromises to quantum efficiency. These advantages translate into several clinical applications. Metal artifacts, beam hardening artifacts, and noise streaks from photon starvation can be better mitigated using PCD CT. Certain incidental findings can be better characterized using the spectral information from PCD CT. High-contrast, high-resolution structures such as the temporal bone can be better visualized using PCD CT and at greatly reduced dose. We also discuss new possibilities on the horizon, including new contrast agents, and how anticipated improvements in PCD CT will translate to performance in these applications.
Collapse
Affiliation(s)
- Scott S Hsieh
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | - Shuai Leng
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | | - Shengzhen Tao
- Department of Radiology at the Mayo Clinic, Rochester MN 55905 USA
| | | |
Collapse
|
44
|
Si-Mohamed SA, Sigovan M, Hsu JC, Tatard-Leitman V, Chalabreysse L, Naha PC, Garrivier T, Dessouky R, Carnaru M, Boussel L, Cormode DP, Douek PC. In Vivo Molecular K-Edge Imaging of Atherosclerotic Plaque Using Photon-counting CT. Radiology 2021; 300:98-107. [PMID: 33944628 PMCID: PMC8217298 DOI: 10.1148/radiol.2021203968] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background Macrophage burden is a major factor in the risk of atherosclerotic plaque rupture, and its evaluation remains challenging with molecular noninvasive imaging approaches. Photon-counting CT (PCCT) with k-edge imaging aims to allow for the specific detection of macrophages using gold nanoparticles. Purpose To perform k-edge imaging in combination with gold nanoparticles to detect and quantify the macrophage burden within the atherosclerotic aortas of rabbits. Materials and Methods Atherosclerotic and control New Zealand white rabbits were imaged before and at several time points up to 2 days after intravenous injection of gold nanoparticles (3.5 mL/kg, 65 mg gold per milliliter). Aortic CT angiography was performed at the end of the follow-up using an intravenous injection of an iodinated contrast material. Gold k-edge and conventional CT images were reconstructed for qualitative and quantitative assessment of the macrophage burden. PCCT imaging results were compared with findings at histologic examination, quantitative histomorphometry, transmission electron microscopy, and quantitative inductively coupled plasma optical emission spectrometry. Pearson correlations between the macrophage area measured in immunostained sections and the concentration of gold and attenuation measured in the corresponding PCCT sections were calculated. Results Seven rabbits with atherosclerosis and four control rabbits without atherosclerosis were analyzed. In atherosclerotic rabbits, calcifications were observed along the aortic wall before injection. At 2 days after injection of gold nanoparticles, only gold k-edge images allowed for the distinction of plaque enhancement within calcifications and for lumen enhancement during angiography. A good correlation was observed between the gold concentration measured within the wall and the macrophage area in 35 plaques (five per rabbit) (r = 0.82; 95% CI: 0.67, 0.91; P < .001), which was higher than that observed on conventional CT images (r = 0.41; 95% CI: 0.09, 0.65; P = .01). Transmission electron microscopy and inductively coupled plasma optical emission spectrometry analyses confirmed the gold k-edge imaging findings. Conclusion Photon-counting CT with gold nanoparticles allowed for the noninvasive evaluation of both molecular and anatomic information in vivo in rabbits with atherosclerotic plaques. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Leiner in this issue.
Collapse
Affiliation(s)
- Salim A Si-Mohamed
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Monica Sigovan
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Jessica C Hsu
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Valérie Tatard-Leitman
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Lara Chalabreysse
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Pratap C Naha
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Thibaut Garrivier
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Riham Dessouky
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Miruna Carnaru
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Loic Boussel
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - David P Cormode
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| | - Philippe C Douek
- From the University of Lyon, National Institute of Applied Sciences of Lyon, University Claude Bernard Lyon 1, Jean Monnet University-Saint Etienne, French National Centre for Scientific Research, Institut national de la santé et de la recherche médicale, Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé Unité mixte de recherche 5220, U1206, F-69621, Lyon, France (S.A.S.M., M.S., V.T.L., R.D., L.B., P.C.D.); Departments of Radiology (S.A.S.M., T.G., L.B., P.C.D.) and Pathology (L.C.), Hospices Civils de Lyon, Lyon, France; Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pa (J.C.H., P.C.N., D.P.C.); Department of Radiology, Faculty of Medicine, Zagazig University, Egypt (R.D.); and Department of Rheumatology, Allergy, and Immunology, Yale University, New Haven, Conn (M.C.)
| |
Collapse
|
45
|
Flohr T, Petersilka M, Henning A, Ulzheimer S, Ferda J, Schmidt B. Photon-counting CT review. Phys Med 2020; 79:126-136. [DOI: 10.1016/j.ejmp.2020.10.030] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 10/26/2020] [Accepted: 10/29/2020] [Indexed: 01/30/2023] Open
|
46
|
Kay FU. Dual-energy CT and coronary imaging. Cardiovasc Diagn Ther 2020; 10:1090-1107. [PMID: 32968662 PMCID: PMC7487394 DOI: 10.21037/cdt.2020.04.04] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Accepted: 04/03/2020] [Indexed: 12/12/2022]
Abstract
Dual-energy computed tomography has been proposed for enhancing the evaluation of coronary artery disease in many fronts. However, the clinical translation of such applications has followed a slower pace of clinical translation. This paper will review the evidence supporting the use of dual-energy computed tomography in coronary artery disease (CAD) and provide some practical illustrations, while underscoring the challenges and gaps in knowledge that have contributed to this phenomenon.
Collapse
Affiliation(s)
- Fernando Uliana Kay
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
47
|
|
48
|
Flohr T, Ulzheimer S, Petersilka M, Schmidt B. Basic principles and clinical potential of photon-counting detector CT. ACTA ACUST UNITED AC 2020. [DOI: 10.1007/s42058-020-00029-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|