1
|
Xu Y, Lin J, Gao JM, Yuan Y. Ultrasonographic assessment of the risk of free-floating thrombus detachment in the lower extremity deep veins in patients with fracture. Clin Imaging 2024; 115:110302. [PMID: 39317115 DOI: 10.1016/j.clinimag.2024.110302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Revised: 09/13/2024] [Accepted: 09/13/2024] [Indexed: 09/26/2024]
Abstract
OBJECTIVE To explore the ultrasonographic features and influencing factors of free-floating thrombus (FFT) detachment in the lower extremity deep veins (LEDVs) of patients with fractures. METHODS Clinical data of patients diagnosed with FFT in the LEDVs and implanted with an inferior vena cava filter (IVCF) in our hospital between July 2021 and August 2023 were retrospectively analysed. The patients were divided into the thrombus detachment group (the experimental group, n = 92) and the non-thrombus detachment group (the control group, n = 103) based on the presence of detached thrombus in the IVCF. The effects of thrombus echogenicity, floating degree, thrombus location, thrombin time, D-dimer and fibrinogen on thrombus shedding were analysed. The nomogram method was used to establish the model and predict the probability of delayed postoperative recovery. RESULTS The proportions of patients with extremely hypoechoic thrombus and medium and high floating degrees increased in the experimental group compared with those in the control group, and the differences between the two groups were statistically significant (P < 0.05). Extremely hypoechoic thrombus (P = 0.021, 95 % CI: 1.109-13.748) and high (P = 0.001, 95 % CI: 3.854-28.573) and medium floating degrees (P = 0.004, 95 % CI: 1.792-13.453) were risk factors for deep veins FFT (DV FFT) detachment. The results of receiver operating characteristic curve analysis showed that the area under the curve of the model was 0.893, with a 95 % CI of 0.856-0.937, indicating a high prediction accuracy. CONCLUSION Ultrasonographic parameters, including thrombus echogenicity and floating degree, are valuable in predicting DV FFT detachment in patients with traumatic fractures, providing references for IVCF implantation.
Collapse
Affiliation(s)
- Yang Xu
- Department of Ultrasound, Tianjin Hospital, Tianjin 300211, China
| | - Jing Lin
- Department of Oncology, Xinjiang Medical University Affiliated Cancer Hospital, Urumqi 830017, China
| | - Jin-Mei Gao
- Department of Ultrasound, Tianjin Hospital, Tianjin 300211, China
| | - Yu Yuan
- Department of Ultrasound, Tianjin Hospital, Tianjin 300211, China.
| |
Collapse
|
2
|
Bosio G, Destrempes F, Roy Cardinal MH, Cloutier G. Effect of rt-PA on Shear Wave Mechanical Assessment and Quantitative Ultrasound Properties of Blood Clot Kinetics In Vitro. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:829-840. [PMID: 38205972 DOI: 10.1002/jum.16411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/21/2023] [Accepted: 12/26/2023] [Indexed: 01/12/2024]
Abstract
OBJECTIVE The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow-up and to detect treatment-resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters. METHODS Blood from 10 pigs was collected to form three clots per pig in gelatin phantoms. Clots were subjected to 1) no treatment, 2) rt-PA (recombinant tissue plasminogen activator) treatment after 20 minutes of clotting, and 3) rt-PA treatment after 60 minutes of clotting. Clots were weighted before and after the experiment to assess the treatment effect by the mass loss. The clot kinetics was studied over 100 minutes using elastography (Young's modulus, shear wave dispersion, and shear wave attenuation). Homodyne K-distribution (HKD) parameters derived from speckle statistics were also studied during clot formation and dissolving (diffuse-to-total signal power ratio and intensity parameters). RESULTS Treated clots loosed significantly more mass than non-treated ones (P < .005). A significant increase in Young's modulus was observed over time (P < .001), and significant reductions were seen for treated clots at 20 or 60 minutes compared with untreated ones (P < .001). The shear wave dispersion differed for treated clots at 60 minutes versus no treatments (P < .001). The shear wave attenuation decreased over time (P < .001), and was different for clots treated at 20 minutes versus no treatments (P < .031). The HKD intensity parameter varied over time (P < .032), and was lower for clots treated at 20 and 60 minutes than those untreated (P < .001 and P < .02). CONCLUSION The effect of rt-PA treatment could be confirmed by a decrease in Young's modulus and HKD intensity parameter. The shear wave dispersion and shear wave attenuation were sensitive to late and early treatments, respectively. The Young's modulus, shear wave attenuation, and HKD intensity parameter varied over time despite treatment.
Collapse
Affiliation(s)
- Guillaume Bosio
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Bosio G, Destrempes F, Yazdani L, Roy Cardinal MH, Cloutier G. Resonance, Velocity, Dispersion, and Attenuation of Ultrasound-Induced Shear Wave Propagation in Blood Clot In Vitro Models. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2024; 43:535-551. [PMID: 38108551 DOI: 10.1002/jum.16387] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 11/24/2023] [Accepted: 11/25/2023] [Indexed: 12/19/2023]
Abstract
OBJECTIVE Improve the characterization of mechanical properties of blood clots. Parameters derived from shear wave (SW) velocity and SW amplitude spectra were determined for gel phantoms and in vitro blood clots. METHODS Homogeneous phantoms and phantoms with gel or blood clot inclusions of different diameters and mechanical properties were analyzed. SW amplitude spectra were used to observe resonant peaks. Parameters derived from those resonant peaks were related to mimicked blood clot properties. Three regions of interest were tested to analyze where resonances occurred the most. For blood experiments, 20 samples from different pigs were analyzed over time during a 110-minute coagulation period using the Young modulus, SW frequency dispersion, and SW attenuation. RESULTS The mechanical resonance was manifested by an increase in the number of SW spectral peaks as the inclusion diameter was reduced (P < .001). In blood clot inclusions, the Young modulus increased over time during coagulation (P < .001). Descriptive spectral parameters (frequency peak, bandwidth, and distance between resonant peaks) were linearly correlated with clot elasticity values (P < .001) with R2 = .77 for the frequency peak, .60 for the bandwidth, and .48 for the distance between peaks. The SW dispersion and SW attenuation reflecting the viscous behavior of blood clots decreased over time (P < .001), mainly in the early stage of coagulation (first minutes). CONCLUSION The confined soft inclusion configuration favored SW mechanical resonances potentially challenging the computation of spectral-based parameters, such as the SW attenuation. The impact of resonances can be reduced by properly selecting the region of interest for data analysis.
Collapse
Affiliation(s)
- Guillaume Bosio
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - François Destrempes
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Ladan Yazdani
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Marie-Hélène Roy Cardinal
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
| | - Guy Cloutier
- Institute of Biomedical Engineering, University of Montreal, Montreal, Quebec, Canada
- Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center (CRCHUM), Montreal, Quebec, Canada
- Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montreal, Montreal, Quebec, Canada
| |
Collapse
|
4
|
Li X, Ruff C, Rafailidis V, Grozinger G, Cokkinos D, Kirksey L, Levitin A, Gadani S, Partovi S. Noninvasive and invasive imaging of lower-extremity acute and chronic venous thrombotic disease. Vasc Med 2023; 28:592-603. [PMID: 37792749 DOI: 10.1177/1358863x231198069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/06/2023]
Abstract
The spectrum of venous thromboembolic (VTE) disease encompasses both acute deep venous thrombosis (DVT) and chronic postthrombotic changes (CPC). A large percentage of acute DVT patients experience recurrent VTE despite adequate anticoagulation, and may progress to CPC. Further, the role of iliocaval venous obstruction (ICVO) in lower-extremity VTE has been increasingly recognized in recent years. Imaging continues to play an important role in both acute and chronic venous disease. Venous duplex ultrasound remains the gold standard for diagnosing acute VTE. However, imaging of CPC is more complex and may involve computed tomography, magnetic resonance, contrast-enhanced ultrasound, or intravascular ultrasound. In this narrative review, we aim to discuss the full spectrum of venous disease imaging for both acute and chronic venous thrombotic disease.
Collapse
Affiliation(s)
- Xin Li
- Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA, USA
| | - Christer Ruff
- Department of Diagnostic and Interventional Radiology, University of Tubingen, Tubingen, Germany
- Department of Diagnostic and Interventional Neuroradiology, University of Tubingen, Tubingen, Germany
| | - Vasileios Rafailidis
- Department of Clinical Radiology, AHEPA University Hospital of Thessaloniki, Thessaloniki, Greece
| | - Gerd Grozinger
- Department of Diagnostic and Interventional Radiology, University of Tubingen, Tubingen, Germany
| | | | - Levester Kirksey
- Department of Vascular Surgery, The Cleveland Clinic Foundation, Cleveland, OH, USA
| | - Abraham Levitin
- Division of Interventional Radiology, The Cleveland Clinic Imaging Institute, Cleveland, OH, USA
| | - Sameer Gadani
- Division of Interventional Radiology, The Cleveland Clinic Imaging Institute, Cleveland, OH, USA
| | - Sasan Partovi
- Division of Interventional Radiology, The Cleveland Clinic Imaging Institute, Cleveland, OH, USA
| |
Collapse
|
5
|
İnce S, Özgokçe M, Özkaçmaz S, Dündar İ, Türko E, Ayyıldız VA, Göya C. Comparison of Medical Treatment Efficiency With Shear Wave Elastography Values of Thrombus in Patients With Lower Extremity Deep Vein Thrombosis. Ultrasound Q 2023; 39:158-164. [PMID: 37289425 DOI: 10.1097/ruq.0000000000000643] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
ABSTRACT In lower-extremity deep vein thrombosis (DVT), thrombus age is essential for successful treatment. The aim of our study was to compare the shear wave elastography (SWE) values measured before treatment and achieved lumen patency after treatment in lower-extremity DVT patients with total occlusion. Patients diagnosed with DVT in the acute-subacute stage (<4 week) with total thrombosis in lower extremity were included in this prospective study. Shear wave elastography measurements were performed where the thrombus was most prominent and homogeneous. To evaluate patient response to treatment, lumen patency (partial [>25%] or total recanalization) was examined using color Doppler imaging in the first and third months posttreatment. Shear wave elastography values with and without patency were compared using an independent t test. Among 75 patients in this study, at the first-month color Doppler imaging examination, the SWE values were 1.77 ± 0.49 (1.09-3.03) m/s in patients who achieved lumen patency (n = 42) and 2.21 ± 0.54 (1.24-3.36) m/s in those who did not show lumen patency (n = 33). The difference between the groups' mean elastography value was statistically significant ( P < 0.001). At the third-month examination, the SWE values were 1.76 ± 0.46 (1.09-3.03) m/s in patients with lumen patency (n = 55) and 2.52 ± 0.48 (1.74-3.36) in patients without lumen patency (n = 20). The difference between the 2 groups' mean elastography value was statistically significant ( P < 0.001). We concluded that it is more difficult to achieve lumen patency in veins occluded by thrombus with higher elasto values, and endovascular interventional procedures should be considered during the initial treatment of high SWE value thrombosis.
Collapse
Affiliation(s)
- Suat İnce
- Department of Radiology, Van Training and Research Hospital
| | - Mesut Özgokçe
- Department of Radiology, Medical Faculty, Van Yuzuncu Yıl University, Van
| | - Sercan Özkaçmaz
- Department of Radiology, Medical Faculty, Van Yuzuncu Yıl University, Van
| | - İlyas Dündar
- Department of Radiology, Medical Faculty, Van Yuzuncu Yıl University, Van
| | - Ensar Türko
- Department of Radiology, Medical Faculty, Van Yuzuncu Yıl University, Van
| | - Veysel A Ayyıldız
- Department of Radiology, Medical Faculty, Süleyman Demirel University, Isparta, Turkey
| | - Cemil Göya
- Department of Radiology, Medical Faculty, Van Yuzuncu Yıl University, Van
| |
Collapse
|
6
|
Santini P, Esposto G, Ainora ME, Lupascu A, Gasbarrini A, Zocco MA, Pola R. Ultrasound Elastography to Assess Age of Deep Vein Thrombosis: A Systematic Review. Diagnostics (Basel) 2023; 13:2075. [PMID: 37370970 DOI: 10.3390/diagnostics13122075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2023] [Revised: 06/02/2023] [Accepted: 06/12/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND AND AIMS Deep-vein thrombosis (DVT) is a widely diffused condition, and its accurate staging has major clinical and therapeutic implications. Ultrasound elastography (UE) is a rapidly evolving imaging technique that allows quantification of elastic tissue properties and could play a crucial role in determining thrombus age. The aim of this review is to find clinical evidence regarding the application of UE in the evaluation of DVT and its usefulness in differentiating thrombosis age. METHODS A literature search of clinical studies was performed to identify the ability of UE of discriminate acute, subacute, and chronic DVT. Heterogeneity and publication bias were calculated. In accordance with the study protocol, a qualitative analysis of the evidence was planned. The results were summarized with a comprehensive summary table of study characteristics and baseline characteristics of participant patients. RESULTS Nine studies matched the predetermined eligibility requirements for this systematic review regarding the risk of bias; the greatest criticalities were found within the domains of patient selection and index test. Based on the quality assessment, two publications were excluded from the qualitative synthesis because of the presence of significant applicability concerns. Among the seven studies that were considered eligible for qualitative synthesis, four evaluated strain elastography and three evaluated shear-wave elastography. Despite significant differences concerning study design, thrombus age definitions, and patient characteristics, nearly all studies demonstrated an increase in thrombus stiffness according to DVT age. CONCLUSIONS UE could play a key role in routine ultrasound examination of DVT. The measurement of thrombus stiffness has a high biological plausibility and its use is supported by the finding of a correlation between the stiffness and the progression of the DVT age.
Collapse
Affiliation(s)
- Paolo Santini
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Giorgio Esposto
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Maria Elena Ainora
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Andrea Lupascu
- Section of Medical Angiology, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Antonio Gasbarrini
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Maria Assunta Zocco
- Department of Internal Medicine and Gastroenterology, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| | - Roberto Pola
- Section of Internal Medicine and Thromboembolic Diseases, Department of Medicine, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Catholic University of Rome, 00168 Rome, Italy
| |
Collapse
|
7
|
Hendley SA, Dimov A, Bhargava A, Snoddy E, Mansour D, Afifi RO, Wool GD, Zha Y, Sammet S, Lu ZF, Ahmed O, Paul JD, Bader KB. Assessment of histological characteristics, imaging markers, and rt-PA susceptibility of ex vivo venous thrombi. Sci Rep 2021; 11:22805. [PMID: 34815441 PMCID: PMC8610976 DOI: 10.1038/s41598-021-02030-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 11/08/2021] [Indexed: 12/27/2022] Open
Abstract
Venous thromboembolism is a significant source of morbidity and mortality worldwide. Catheter-directed thrombolytics is the primary treatment used to relieve critical obstructions, though its efficacy varies based on the thrombus composition. Non-responsive portions of the specimen often remain in situ, which prohibits mechanistic investigation of lytic resistance or the development of diagnostic indicators for treatment outcomes. In this study, thrombus samples extracted from venous thromboembolism patients were analyzed ex vivo to determine their histological properties, susceptibility to lytic therapy, and imaging characteristics. A wide range of thrombus morphologies were observed, with a dependence on age and etymology of the specimen. Fibrinolytic inhibitors including PAI-1, alpha 2-antiplasmin, and TAFI were present in samples, which may contribute to the response venous thrombi to catheter-directed thrombolytics. Finally, a weak but significant correlation was observed between the response of the sample to lytic drug and its magnetic microstructure assessed with a quantitative MRI sequence. These findings highlight the myriad of changes in venous thrombi that may promote lytic resistance, and imaging metrics that correlate with treatment outcomes.
Collapse
Affiliation(s)
- Samuel A Hendley
- Committee on Medical Physics, University of Chicago, Chicago, IL, 60637, USA
| | - Alexey Dimov
- Department of Radiology, Weill Cornell Medicine, New York, NY, 10021, USA
| | - Aarushi Bhargava
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Erin Snoddy
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Daniel Mansour
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Rana O Afifi
- Department of Cardiothoracic and Vascular Surgery, University of Texas at Houston, Houston, TX, 77030, USA
| | - Geoffrey D Wool
- Department of Pathology, University of Chicago, Chicago, IL, 60637, USA
| | - Yuanyuan Zha
- The Human Immunological Monitoring Facility, University of Chicago, Chicago, IL, 60637, USA
| | - Steffen Sammet
- Committee on Medical Physics, University of Chicago, Chicago, IL, 60637, USA
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Zheng Feng Lu
- Committee on Medical Physics, University of Chicago, Chicago, IL, 60637, USA
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Osman Ahmed
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA
| | - Jonathan D Paul
- Department of Medicine, University of Chicago, Chicago, IL, 60637, USA
| | - Kenneth B Bader
- Committee on Medical Physics, University of Chicago, Chicago, IL, 60637, USA.
- Department of Radiology, University of Chicago, Chicago, IL, 60637, USA.
| |
Collapse
|