1
|
Bureau L, Coupier G, Salez T. Lift at low Reynolds number. THE EUROPEAN PHYSICAL JOURNAL. E, SOFT MATTER 2023; 46:111. [PMID: 37957450 DOI: 10.1140/epje/s10189-023-00369-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Accepted: 10/19/2023] [Indexed: 11/15/2023]
Abstract
Lift forces are widespread in hydrodynamics. These are typically observed for big and fast objects and are often associated with a combination of fluid inertia (i.e. large Reynolds numbers) and specific symmetry-breaking mechanisms. In contrast, the properties of viscosity-dominated (i.e. low Reynolds numbers) flows make it more difficult for such lift forces to emerge. However, the inclusion of boundary effects qualitatively changes this picture. Indeed, in the context of soft and biological matter, recent studies have revealed the emergence of novel lift forces generated by boundary softness, flow gradients and/or surface charges. The aim of the present review is to gather and analyse this corpus of literature, in order to identify and unify the questioning within the associated communities, and pave the way towards future research.
Collapse
Affiliation(s)
- Lionel Bureau
- Univ. Grenoble Alpes, CNRS, LIPhy, 38000, Grenoble, France.
| | | | - Thomas Salez
- Univ. Bordeaux, CNRS, LOMA, UMR 5798, 33400, Talence, France.
| |
Collapse
|
2
|
JIRARI IMANEEL, BAROUDI ADILEL, AMMAR AMINE. EFFECT OF ARTERIOLAR DISTENSIBILITY ON THE LATERAL MIGRATION OF LIQUID-FILLED MICROPARTICLES FLOWING IN A HUMAN ARTERIOLE. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
A promising advance of bioengineering consists in the development of micro-nanoparticles as drug delivery vehicles injected intravenously or intraarterialy for targeted treatment. Proficient functioning of drug carries is conditioned by a reliable prediction of pharmacokinetics in human as well as their dynamical behavior once injected in blood stream. In this study, we aim to provide a reliable numerical prediction of dynamical behavior of microparticles in human arteriole focusing on the crucial mechanism of lateral migration. The dynamical response of the microparticle upon blood flow and arteriolar distensibility is investigated by varying main controlling parameters: viscosity ratio, confinement and capillary number. The influence of the hyperelastic arteriolar wall is highlighted through comparison with an infinitely rigid arteriolar wall. The hydrodynamic interaction in a microparticle train is examined. Fluid–structure interaction is solved by the Arbitrary Lagrangian–Eulerian method using the COMSOL Multiphysics software.
Collapse
Affiliation(s)
- IMANE EL JIRARI
- LAMPA, Arts et Metiers Institute of Technology, 49035 Angers, France
| | - ADIL EL BAROUDI
- LAMPA, Arts et Metiers Institute of Technology, 49035 Angers, France
| | - AMINE AMMAR
- LAMPA, Arts et Metiers Institute of Technology, 49035 Angers, France
| |
Collapse
|
3
|
Koolivand A, Dimitrakopoulos P. Motion of an Elastic Capsule in a Trapezoidal Microchannel Under Stokes Flow Conditions. Polymers (Basel) 2020; 12:E1144. [PMID: 32429526 PMCID: PMC7284694 DOI: 10.3390/polym12051144] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 05/14/2020] [Accepted: 05/14/2020] [Indexed: 12/29/2022] Open
Abstract
Even though the research interest in the last decades has been mainly focused on the capsule dynamics in cylindrical or rectangular ducts, channels with asymmetric cross-sections may also be desirable especially for capsule migration and sorting. Therefore, in the present study we investigate computationally the motion of an elastic spherical capsule in an isosceles trapezoidal microchannel at low and moderate flow rates under the Stokes regime. The steady-state capsule location is quite close to the location where the single-phase velocity of the surrounding fluid is maximized. Owing to the asymmetry of the trapezoidal channel, the capsule's steady-state shape is asymmetric while its membrane slowly tank-treads. In addition, our investigation reveals that tall trapezoidal channels with low base ratios produce significant off-center migration for large capsules compared to that for smaller capsules for a given channel length. Thus, we propose a microdevice for the sorting of artificial and physiological capsules based on their size, by utilizing tall trapezoidal microchannels with low base ratios. The proposed sorting microdevice can be readily produced via glass fabrication or as a microfluidic device via micromilling, while the required flow conditions do not cause membrane rupture.
Collapse
Affiliation(s)
- Abdollah Koolivand
- Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, MD 20742, USA
| | - Panagiotis Dimitrakopoulos
- Department of Chemical and Biomolecular Engineering, University of Maryland, College Park, MD 20742, USA
| |
Collapse
|
4
|
Losserand S, Coupier G, Podgorski T. Migration velocity of red blood cells in microchannels. Microvasc Res 2019; 124:30-36. [PMID: 30831125 DOI: 10.1016/j.mvr.2019.02.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 02/18/2019] [Accepted: 02/18/2019] [Indexed: 11/25/2022]
Abstract
The lateral migration of red blood cells (RBCs) in confined channel flows is an important ingredient of microcirculatory hydrodynamics and is involved in the development of a cell free layer near vessel walls and influences the distribution of RBCs in networks. It is also relevant to a number of lab-on-chip applications. This migration is a consequence of their deformability and is due to the combined effects of hydrodynamic wall repulsion and the curvature of the fluid velocity profile. We performed microfluidic experiments with dilute suspensions of RBCs in which the trajectories and migration away from the channel wall are analyzed to extract the mean behavior, from which we propose a generic scaling law for the transverse migration velocity valid in a whole range of parameters relevant to microcirculatory and practical situations. Experiments with RBCs of different mechanical properties (separated by density gradient sedimentation or fixed with glutaraldehyde) show the influence of this parameter which can induce significant dispersion of the trajectories.
Collapse
Affiliation(s)
| | - Gwennou Coupier
- Université Grenoble Alpes, CNRS, LIPhy, Grenoble F-38000, France
| | - Thomas Podgorski
- Université Grenoble Alpes, CNRS, LIPhy, Grenoble F-38000, France
| |
Collapse
|
5
|
Ye H, Shen Z, Yu L, Wei M, Li Y. Manipulating nanoparticle transport within blood flow through external forces: an exemplar of mechanics in nanomedicine. Proc Math Phys Eng Sci 2018; 474:20170845. [PMID: 29662344 DOI: 10.1098/rspa.2017.0845] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/16/2018] [Indexed: 02/05/2023] Open
Abstract
A large number of nanoparticles (NPs) have been raised for diverse biomedical applications and some of them have shown great potential in treatment and imaging of diseases. Design of NPs is essential for delivery efficacy due to a number of biophysical barriers, which prevents the circulation of NPs in vascular flow and their accumulation at tumour sites. The physiochemical properties of NPs, so-called '4S' parameters, such as size, shape, stiffness and surface functionalization, play crucial roles in their life journey to be delivered to tumour sites. NPs can be modified in various ways to extend their blood circulation time and avoid their clearance by phagocytosis, and efficiently diffuse into tumour cells. However, it is difficult to overcome these barriers simultaneously by a simple combination of '4S' parameters for NPs. At this moment, external triggerings are necessary to guide the movement of NPs, which include light, ultrasound, magnetic field, electrical field and chemical interaction. The delivery system can be constructed to be sensitive to these external stimuli which can reduce the non-specific toxicity and improve the efficacy of the drug-delivery system. From a mechanics point of view, we discuss how different forces play their roles in the margination of NPs in blood flow and tumour microvasculature.
Collapse
Affiliation(s)
- Huilin Ye
- Department of Mechanical Engineering, University of Connecticut, 191 Auditorium Road, Unit 3139, Storrs, CT 06269, USA
| | - Zhiqiang Shen
- Department of Mechanical Engineering, University of Connecticut, 191 Auditorium Road, Unit 3139, Storrs, CT 06269, USA
| | - Le Yu
- Department of Materials Science and Engineering, University of Connecticut, 97 North Eagleville Road, Unit 3136, Storrs, CT 06269, USA
| | - Mei Wei
- Department of Materials Science and Engineering, University of Connecticut, 97 North Eagleville Road, Unit 3136, Storrs, CT 06269, USA.,Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Unit 3136, Storrs, CT 06269, USA
| | - Ying Li
- Department of Mechanical Engineering, University of Connecticut, 191 Auditorium Road, Unit 3139, Storrs, CT 06269, USA.,Institute of Materials Science, University of Connecticut, 97 North Eagleville Road, Unit 3136, Storrs, CT 06269, USA
| |
Collapse
|
6
|
He L, Luo Z, Liu WR, Bai B. Capsule equilibrium positions near channel center in Poiseuille flow. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2017.07.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
7
|
Neubauer MP, Poehlmann M, Fery A. Microcapsule mechanics: from stability to function. Adv Colloid Interface Sci 2014; 207:65-80. [PMID: 24345731 DOI: 10.1016/j.cis.2013.11.016] [Citation(s) in RCA: 100] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2013] [Revised: 11/18/2013] [Accepted: 11/21/2013] [Indexed: 01/22/2023]
Abstract
Microcapsules are reviewed with special emphasis on the relevance of controlled mechanical properties for functional aspects. At first, assembly strategies are presented that allow control over the decisive geometrical parameters, diameter and wall thickness, which both influence the capsule's mechanical performance. As one of the most powerful approaches the layer-by-layer technique is identified. Subsequently, ensemble and, in particular, single-capsule deformation techniques are discussed. The latter generally provide more in-depth information and cover the complete range of applicable forces from smaller than pN to N. In a theory chapter, we illustrate the physics of capsule deformation. The main focus is on thin shell theory, which provides a useful approximation for many deformation scenarios. Finally, we give an overview of applications and future perspectives where the specific design of mechanical properties turns microcapsules into (multi-)functional devices, enriching especially life sciences and material sciences.
Collapse
|
8
|
Grandchamp X, Coupier G, Srivastav A, Minetti C, Podgorski T. Lift and down-gradient shear-induced diffusion in red blood cell suspensions. PHYSICAL REVIEW LETTERS 2013; 110:108101. [PMID: 23521300 DOI: 10.1103/physrevlett.110.108101] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Indexed: 05/24/2023]
Abstract
The distribution of red blood cells (RBCs) in a confined channel flow is inhomogeneous and shows a marked depletion near the walls due to a competition between migration away from the walls and shear-induced diffusion resulting from interactions between particles. We investigated the lift of RBCs in a shear flow near a wall and measured a significant lift velocity despite the tumbling motion of cells. We also provide values for the collective and anisotropic shear-induced diffusion of a cloud of RBCs, both in the direction of shear and in the direction of vorticity. A generic down-gradient subdiffusion characterized by an exponent 1/3 is highlighted.
Collapse
Affiliation(s)
- Xavier Grandchamp
- Laboratoire Interdisciplinaire de Physique, CNRS - UMR 5588, Université Grenoble I, BP 87, 38402 Saint Martin d'Hères Cedex, France
| | | | | | | | | |
Collapse
|
9
|
Chang CB, Huang WX, Sung HJ. Lateral migration of an elastic capsule by optical force in a uniform flow. PHYSICAL REVIEW. E, STATISTICAL, NONLINEAR, AND SOFT MATTER PHYSICS 2012; 86:066306. [PMID: 23368037 DOI: 10.1103/physreve.86.066306] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2012] [Indexed: 06/01/2023]
Abstract
The lateral migration of an elastic capsule under an optical force in a uniform flow was studied to show the separation characteristics according to the elastic properties in the cross-type optical separator. The initially spherical capsule was moved through the fluid flow using a laser beam with a Gaussian distribution focused along the direction normal to the flow device surface. To simulate such a system, a penalty immersed boundary method was adopted to enable fluid-membrane coupling, and a dynamic ray tracing method was applied to the optical force calculation. The effects of the elastic properties of the capsule membrane (the surface Young's modulus and the bending modulus) on the lateral migration were studied. By increasing the surface Young's modulus, the capsule deformed less and the migration distance increased; however, buckling occurred in the capsule with a high surface Young's modulus. Buckling could be suppressed by increasing the bending rigidity. The effects of the flow velocity and the laser beam power were also examined. In the simulation, the S number, i.e., the ratio of the optical force to the viscous force, was adjusted by decreasing the flow velocity or increasing the laser beam power. The migration distance increased as the S number increased, and a constant lateral migration distance was obtained for a rigid particle for a given S number. An elastic capsule under conditions intermediate between a fixed flow velocity and a fixed laser beam power, however, did not yield a constant lateral migration distance due to the extent of the deformation in the different situations. To predict the lateral migration distance of an elastic capsule, a nondimensional parameter, S_{e}, was defined to include the effects of the optical force, the elastic force, and the fluid viscous force. A unified tendency of the lateral migration distance with S_{e} was obtained for capsules with intermediate elasticity, by varying either the flow velocity or the laser beam power.
Collapse
Affiliation(s)
- Cheong Bong Chang
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Korea
| | | | | |
Collapse
|