1
|
Basak M, Mitra S, Agnihotri SK, Jain A, Vyas A, Bhatt MLB, Sachan R, Sachdev M, Nemade HB, Bandyopadhyay D. Noninvasive Point-of-Care Nanobiosensing of Cervical Cancer as an Auxiliary to Pap-Smear Test. ACS APPLIED BIO MATERIALS 2021; 4:5378-5390. [PMID: 35007017 DOI: 10.1021/acsabm.1c00470] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A potential cancer antigen (Ag), protein-phosphatase-1-gamma-2 (PP1γ2), with a restricted expression in testis and sperms has been identified as a biomarker specific to cervical cancer (CaCx). Detection of this cancer biomarker antigen (NCB-Ag) in human urine opens up the possibility of noninvasive detection of CaCx to supplement the dreaded and invasive Pap-smear test. A colorimetric response of an assembly of gold nanoparticles (Au NPs) has been employed for the quantitative, noninvasive, and point-of-care-testing of CaCx in the urine. In order to fabricate the immunosensor, Au NPs of sizes ∼5-20 nm have been chemically modified with a linker, 3,3'-di-thio-di-propionic-acid-di(n-hydroxy-succinimide-ester) (DTSP) to attach the antibody (Ab) specific to the NCB-Ag. Interestingly, the addition of Ag to the composite of Ab-DTSP-Au NPs leads to a significant hypsochromic shift due to a localized surface plasmon resonance phenomenon, which originates from the specific epitope-paratope interaction between the NCB-Ag and Ab-DTSP-Au NPs. The variations in the absorbance and wavelength shift during such attachments of different concentrations of NCB-Ag on the Ab-DTSP-Au NPs composite have been employed as a calibration to identify NCB-Ag in human urine. An in-house prototype has been assembled by integrating a light-emitting diode of a narrow range wavelength in one side of a cuvette in which the reaction has been performed while a sensitive photodetector to the other side to transduce the transmitted signal associated with the loading of NCB-Ag in the Ab-DTSP-Au NPs composite. The proposed immunosensing platform has been tested against other standard proteins to ensure noninterference alongside proving the proof-for-specificity of the NCB detection.
Collapse
Affiliation(s)
- Mitali Basak
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Shirsendu Mitra
- Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Saurabh Kumar Agnihotri
- Endocrinology, Division, CSIR-Central Drug Research Institute Lucknow, Lucknow, Uttar Pradesh 226 031, India
| | - Ankita Jain
- Endocrinology, Division, CSIR-Central Drug Research Institute Lucknow, Lucknow, Uttar Pradesh 226 031, India
| | - Akanksha Vyas
- Endocrinology, Division, CSIR-Central Drug Research Institute Lucknow, Lucknow, Uttar Pradesh 226 031, India
| | | | - Rekha Sachan
- King George's Medical University, Lucknow, Uttar Pradesh 226 003, India
| | - Monika Sachdev
- Endocrinology, Division, CSIR-Central Drug Research Institute Lucknow, Lucknow, Uttar Pradesh 226 031, India
| | - Harshal B Nemade
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| | - Dipankar Bandyopadhyay
- Centre for Nanotechnology, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India.,Department of Chemical Engineering, Indian Institute of Technology Guwahati, Guwahati, Assam 781039, India
| |
Collapse
|
2
|
Bilican I, Bahadir T, Bilgin K, Guler MT. Alternative screening method for analyzing the water samples through an electrical microfluidics chip with classical microbiological assay comparison of P. aeruginosa. Talanta 2020; 219:121293. [PMID: 32887035 DOI: 10.1016/j.talanta.2020.121293] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2020] [Revised: 06/09/2020] [Accepted: 06/10/2020] [Indexed: 12/13/2022]
Abstract
Pseudomonas aeruginosa is a pathogenic bacterium in fresh water supplies that creates a risk for public health. Microbiological analysis of drinking water samples is time consuming and requires qualified personnel. Here we offer a screening system for rapid analysis of spring water that has the potential to be turned into a point-of-need system by means of simple mechanism. The test, which takes 1 h to complete, electrically interrogates the particles through a microfluidic chip suspended in the water sample. We tested the platform using water samples with micro beads and water samples spiked with P. aeruginosa at various concentrations. The mono disperse micro beads were used to evaluate the performance of the system. The results were verified by the gold standard membrane filtration method, which yielded a positive test result only for the P. aeruginosa spiked samples. Detection of 0-11 k bacteria in 30 μL samples was successfully completed in 1 h and compared with a conventional microbiological method. The presented method is a good candidate for a rapid, on-site, screening test that can result in a significant reduction in cost and analysis time compared to microbiological analyses routinely used in practice.
Collapse
Affiliation(s)
- Ismail Bilican
- Science and Technology Application and Research Center, Aksaray University, Aksaray, 68100, Turkey; UNAM-National Nanotechnology Research Center, Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey
| | - Tolga Bahadir
- Department of Environmental Engineering, Faculty of Engineering, Aksaray University, Aksaray, 68100, Turkey
| | - Kemal Bilgin
- Department of Medical Microbiology, Medical School, Ondokuz Mayis University, Samsun, 55139, Turkey
| | - Mustafa Tahsin Guler
- UNAM-National Nanotechnology Research Center, Institute of Materials Science and Nanotechnology, Bilkent University, 06800, Ankara, Turkey; Department of Physics, Faculty of Art and Science, Kirikkale University, Kirikkale, 71450, Turkey.
| |
Collapse
|
3
|
Catherwood PA, Steele D, Little M, Mccomb S, Mclaughlin J. A Community-Based IoT Personalized Wireless Healthcare Solution Trial. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2018; 6:2800313. [PMID: 29888145 PMCID: PMC5991865 DOI: 10.1109/jtehm.2018.2822302] [Citation(s) in RCA: 79] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 02/13/2018] [Accepted: 03/24/2018] [Indexed: 01/26/2023]
Abstract
This paper presents an advanced Internet of Things point-of-care bio-fluid analyzer; a LoRa/Bluetooth-enabled electronic reader for biomedical strip-based diagnostics system for personalized monitoring. We undertake test simulations (technology trial without patient subjects) to demonstrate potential of long-range analysis, using a disposable test ‘key’ and companion Android app to form a diagnostic platform suitable for remote point-of-care screening for urinary tract infection (UTI). The 868 MHz LoRaWAN-enabled personalized monitor demonstrated sound potential with UTI test results being correctly diagnosed and transmitted to a remote secure cloud server in every case. Tests ranged over distances of 1.1–6.0 Km with radio path losses from 119–141 dB. All tests conducted were correctly and robustly received at the base station and relayed to the secure server for inspection. The UTI test strips were visually inspected for correct diagnosis based on color change and verified as 100% accurate. Results from testing across a number of regions indicate that such an Internet of Things medical solution is a robust and simple way to deliver next generation community-based smart diagnostics and disease management to best benefit patients and clinical staff alike. This significant step can be applied to any type of home or region, particularly those lacking suitable mobile signals, broadband connections, or even landlines. It brings subscription-free long-range bio-telemetry to healthcare providers and offers savings on regular clinician home visits or frequent clinic visits by the chronically ill. This paper highlights practical hurdles in establishing an Internet of Medical Things network, assisting informed deployment of similar future systems.
Collapse
|
4
|
Seo W, Yu W, Tan T, Ziaie B, Jung B. Diaper-Embedded Urinary Tract Infection Monitoring Sensor Module Powered by Urine-Activated Batteries. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:681-691. [PMID: 28422664 DOI: 10.1109/tbcas.2017.2654421] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Urinary tract infection (UTI) is one of the most common infections in humans. UTI is easily treatable using antibiotics if identified in early stage. However, without early identification and treatment, UTI can be a major source of serious complications in geriatric patients, in particular, those suffering from neurodegenerative diseases. Also, for infants who have difficulty in describing their symptoms, UTI may lead to serious development of the disease making early identification of UTI crucial. In this paper, we present a diaper-embedded, wireless, self-powered, and autonomous UTI monitoring sensor module that allows an early detection of UTI with minimal effort. The sensor module consists of a paper-based colorimetric nitrite sensor, urine-activated batteries, a boost dc-dc converter, a low-power sensor interface utilizing pulse width modulation, and a Bluetooth low energy module for wireless transmission. Experimental results show a better detection of nitrite, a surrogate of UTI, than that of conventional dipstick testing. The proposed sensor module achieves a sensitivity of 1.35 ms/(mg/L) and a detection limit of 4 mg/L for nitrite.
Collapse
|
5
|
A capacitive touch screen sensor for detection of urinary tract infections in portable biomedical devices. SENSORS 2014; 14:13851-62. [PMID: 25196109 PMCID: PMC4179013 DOI: 10.3390/s140813851] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2014] [Revised: 07/02/2014] [Accepted: 07/18/2014] [Indexed: 11/17/2022]
Abstract
Incidence of urinary tract infections (UTIs) is the second highest among all infections; thus, there is a high demand for bacteriuria detection. Escherichia coli are the main cause of UTIs, with microscopy methods and urine culture being the detection standard of these bacteria. However, the urine sampling and analysis required for these methods can be both time-consuming and complex. This work proposes a capacitive touch screen sensor (CTSS) concept as feasible alternative for a portable UTI detection device. Finite element method (FEM) simulations were conducted with a CTSS model. An exponential response of the model to increasing amounts of E. coli and liquid samples was observed. A measurable capacitance change due to E. coli presence and a tangible difference in the response given to urine and water samples were also detected. Preliminary experimental studies were also conducted on a commercial CTSS using liquid solutions with increasing amounts of dissolved ions. The CTSS was capable of distinguishing different volumes of liquids, also giving an exponential response. Furthermore, the CTSS gave higher responses to solutions with a superior amount of ions. Urine samples gave the top response among tested liquids. Thus, the CTSS showed the capability to differentiate solutions by their ionic content.
Collapse
|