1
|
Anderson HE, Weir RFF. On the development of optical peripheral nerve interfaces. Neural Regen Res 2019; 14:425-436. [PMID: 30539808 PMCID: PMC6334609 DOI: 10.4103/1673-5374.245461] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2018] [Accepted: 09/19/2018] [Indexed: 11/04/2022] Open
Abstract
Limb loss and spinal cord injury are two debilitating conditions that continue to grow in prevalence. Prosthetic limbs and limb reanimation present two ways of providing affected individuals with means to interact in the world. These techniques are both dependent on a robust interface with the peripheral nerve. Current methods for interfacing with the peripheral nerve tend to suffer from low specificity, high latency and insufficient robustness for a chronic implant. An optical peripheral nerve interface may solve some of these problems by decreasing invasiveness and providing single axon specificity. In order to implement such an interface three elements are required: (1) a transducer capable of translating light into a neural stimulus or translating neural activity into changes in fluorescence, (2) a means for delivering said transducer and (3) a microscope for providing the stimulus light and detecting the fluorescence change. There are continued improvements in both genetically encoded calcium and voltage indicators as well as new optogenetic actuators for stimulation. Similarly, improvements in specificity of viral vectors continue to improve expression in the axons of the peripheral nerve. Our work has recently shown that it is possible to virally transduce axons of the peripheral nerve for recording from small fibers. The improvements of these components make an optical peripheral nerve interface a rapidly approaching alternative to current methods.
Collapse
Affiliation(s)
- Hans E. Anderson
- Department of Bioengineering, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
| | - Richard F. ff. Weir
- Department of Bioengineering, University of Colorado Denver | Anschutz Medical Campus, Aurora, CO, USA
| |
Collapse
|
2
|
Khiarak MN, Gagnon-Turcotte G, Martianova E, Martel CBS, Proulx CD, De Koninck Y, Gosselin B. A Wireless Optoelectronic Neuroscience Platform for Chronic Fluorescence Sensing in Freely Behaving Rodents. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:1608-1611. [PMID: 30440700 DOI: 10.1109/embc.2018.8512653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We present a new head mountable wireless fiber biophotometry microsystem conceived to detect fluorescent signal fluctuations correlated with neuronal activity. The proposed system incorporates all aspects of a conventional tethered fiber-based biophotometry system encompassed into a wireless microsystem. The interface includes an LED as excitation light source, a custom designed CMOS biosensor, a multimode fiber, a microcontroller (MCU), and a wireless data transceiver enclosed within a 3D-printed, small and light weight, plastic housing. Precisely, the system incorporates a new optoelectronic biosensor merging two individual building blocks, namely a low-noise sensing front-end and $\mathrm {a}2 ^{nd}$ order continuous-time $\Sigma \Delta $ modulator (CTSDM), into a single module for enabling high-sensitivity and high energy-efficiency photo-sensing. The proposed CMOS biosensor is implemented in $\mathrm {a}0 .18- \mu m$ CMOS technology, consuming $41 \mu W$ from $\mathrm {a}1 .8- V$ supply voltage, while achieving a peak dynamic range of $86 dB$ over a $50- Hz$ input bandwidth at a 20-kS/s sampling rate. This new interface opens new avenues for conducting in-vivo experiments with live animals.
Collapse
|
3
|
Miao P, Zhang L, Li M, Zhang Y, Feng S, Wang Q, Thakor NV. Chronic wide-field imaging of brain hemodynamics in behaving animals. BIOMEDICAL OPTICS EXPRESS 2017; 8:436-445. [PMID: 28101429 PMCID: PMC5231311 DOI: 10.1364/boe.8.000436] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 12/03/2016] [Accepted: 12/09/2016] [Indexed: 05/21/2023]
Abstract
Chronically monitoring cerebral activities in awake and freely moving status is very important in physiological and pathological studies. We present a novel standalone micro-imager for monitoring the cerebral blood flow (CBF) and total hemoglobin (HbT) activities in freely moving animals using the laser speckle contrast imaging (LSCI) and optical intrinsic signal (OIS) methods. A new cranial window method, using contact lens and wide field optics, is also proposed to achieve the chronic and wide-field imaging of rat's cerebral cortex. The hemodynamic activities of rats' cortex were measured for the first time without restriction of cables or fibers in awake and behaving animals. Chronic imaging showed the increase of CBF and HbT in motor cortex when the rats were climbing on the cage wall. Interestingly, the CBF activation of supplying vessel was smaller than that of parenchyma. Furthermore, after the climbing, CBF demonstrated fully return to the baseline while HbT showed a delayed recovery. The standalone micro-imager technology provides new possibilities of brain imaging in cognitive neuroscience studies.
Collapse
Affiliation(s)
- Peng Miao
- Institute of Biomedical Engineering, School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China; Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, USA;
| | - Lingke Zhang
- Institute of Biomedical Engineering, School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Miao Li
- Institute of Biomedical Engineering, School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Yiguang Zhang
- Institute of Biomedical Engineering, School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Shihan Feng
- Institute of Biomedical Engineering, School of Communication and Information Engineering, Shanghai University, Shanghai 200444, China
| | - Qihong Wang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, USA
| | - Nitish V Thakor
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, USA;
| |
Collapse
|
4
|
Zhang X, Noor MS, McCracken CB, Kiss ZHT, Yadid-Pecht O, Murari K. CMOS Image Sensor and System for Imaging Hemodynamic Changes in Response to Deep Brain Stimulation. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:632-642. [PMID: 26357405 DOI: 10.1109/tbcas.2015.2453256] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Deep brain stimulation (DBS) is a therapeutic intervention used for a variety of neurological and psychiatric disorders, but its mechanism of action is not well understood. It is known that DBS modulates neural activity which changes metabolic demands and thus the cerebral circulation state. However, it is unclear whether there are correlations between electrophysiological, hemodynamic and behavioral changes and whether they have any implications for clinical benefits. In order to investigate these questions, we present a miniaturized system for spectroscopic imaging of brain hemodynamics. The system consists of a 144 ×144, [Formula: see text] pixel pitch, high-sensitivity, analog-output CMOS imager fabricated in a standard 0.35 μm CMOS process, along with a miniaturized imaging system comprising illumination, focusing, analog-to-digital conversion and μSD card based data storage. This enables stand alone operation without a computer, nor electrical or fiberoptic tethers. To achieve high sensitivity, the pixel uses a capacitive transimpedance amplifier (CTIA). The nMOS transistors are in the pixel while pMOS transistors are column-parallel, resulting in a fill factor (FF) of 26%. Running at 60 fps and exposed to 470 nm light, the CMOS imager has a minimum detectable intensity of 2.3 nW/cm(2) , a maximum signal-to-noise ratio (SNR) of 49 dB at 2.45 μW/cm(2) leading to a dynamic range (DR) of 61 dB while consuming 167 μA from a 3.3 V supply. In anesthetized rats, the system was able to detect temporal, spatial and spectral hemodynamic changes in response to DBS.
Collapse
|
5
|
"Optical communication with brain cells by means of an implanted duplex micro-device with optogenetics and Ca(2+) fluoroimaging". Sci Rep 2016; 6:21247. [PMID: 26878910 PMCID: PMC4754641 DOI: 10.1038/srep21247] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Accepted: 01/19/2016] [Indexed: 02/05/2023] Open
Abstract
To better understand the brain function based on neural activity, a minimally invasive analysis technology in a freely moving animal is necessary. Such technology would provide new knowledge in neuroscience and contribute to regenerative medical techniques and prosthetics care. An application that combines optogenetics for voluntarily stimulating nerves, imaging to visualize neural activity, and a wearable micro-instrument for implantation into the brain could meet the abovementioned demand. To this end, a micro-device that can be applied to the brain less invasively and a system for controlling the device has been newly developed in this study. Since the novel implantable device has dual LEDs and a CMOS image sensor, photostimulation and fluorescence imaging can be performed simultaneously. The device enables bidirectional communication with the brain by means of light. In the present study, the device was evaluated in an in vitro experiment using a new on-chip 3D neuroculture with an extracellular matrix gel and an in vivo experiment involving regenerative medical transplantation and gene delivery to the brain by using both photosensitive channel and fluorescent Ca2+ indicator. The device succeeded in activating cells locally by selective photostimulation, and the physiological Ca2+ dynamics of neural cells were visualized simultaneously by fluorescence imaging.
Collapse
|
6
|
Miniaturized optical neuroimaging in unrestrained animals. Neuroimage 2015; 113:397-406. [PMID: 25791782 DOI: 10.1016/j.neuroimage.2015.02.070] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2014] [Revised: 01/26/2015] [Accepted: 02/20/2015] [Indexed: 11/23/2022] Open
Abstract
The confluence of technological advances in optics, miniaturized electronic components and the availability of ever increasing and affordable computational power have ushered in a new era in functional neuroimaging, namely, an era in which neuroimaging of cortical function in unrestrained and unanesthetized rodents has become a reality. Traditional optical neuroimaging required animals to be anesthetized and restrained. This greatly limited the kinds of experiments that could be performed in vivo. Now one can assess blood flow and oxygenation changes resulting from functional activity and image functional response in disease models such as stroke and seizure, and even conduct long-term imaging of tumor physiology, all without the confounding effects of anesthetics or animal restraints. These advances are shedding new light on mammalian brain organization and function, and helping to elucidate loss of this organization or 'dysfunction' in a wide array of central nervous system disease models. In this review, we highlight recent advances in the fabrication, characterization and application of miniaturized head-mounted optical neuroimaging systems pioneered by innovative investigators from a wide array of disciplines. We broadly classify these systems into those based on exogenous contrast agents, such as single- and two-photon microscopy systems; and those based on endogenous contrast mechanisms, such as multispectral or laser speckle contrast imaging systems. Finally, we conclude with a discussion of the strengths and weaknesses of these approaches along with a perspective on the future of this exciting new frontier in neuroimaging.
Collapse
|
7
|
Köklü G, Ghaye J, Etienne-Cummings R, Leblebici Y, De Micheli G, Carrara S. Empowering Low-Cost CMOS Cameras by Image Processing to Reach Comparable Results with Costly CCDs. BIONANOSCIENCE 2013. [DOI: 10.1007/s12668-013-0106-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
O’Sullivan TD, Heitz RT, Parashurama N, Barkin DB, Wooley BA, Gambhir SS, Harris JS, Levi O. Real-time, continuous, fluorescence sensing in a freely-moving subject with an implanted hybrid VCSEL/CMOS biosensor. BIOMEDICAL OPTICS EXPRESS 2013; 4:1332-1341. [PMID: 24009996 PMCID: PMC3756575 DOI: 10.1364/boe.4.001332] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/07/2013] [Revised: 06/05/2013] [Accepted: 06/26/2013] [Indexed: 06/02/2023]
Abstract
Performance improvements in instrumentation for optical imaging have contributed greatly to molecular imaging in living subjects. In order to advance molecular imaging in freely moving, untethered subjects, we designed a miniature vertical-cavity surface-emitting laser (VCSEL)-based biosensor measuring 1cm(3) and weighing 0.7g that accurately detects both fluorophore and tumor-targeted molecular probes in small animals. We integrated a critical enabling component, a complementary metal-oxide semiconductor (CMOS) read-out integrated circuit, which digitized the fluorescence signal to achieve autofluorescence-limited sensitivity. After surgical implantation of the lightweight sensor for two weeks, we obtained continuous and dynamic fluorophore measurements while the subject was un-anesthetized and mobile. The technology demonstrated here represents a critical step in the path toward untethered optical sensing using an integrated optoelectronic implant.
Collapse
Affiliation(s)
- Thomas D. O’Sullivan
- Department of Electrical Engineering, Stanford University, 420 Via Palou, Stanford, CA 94305-4075, USA
- These authors contributed equally to this work
| | - Roxana T. Heitz
- Department of Electrical Engineering, Stanford University, 420 Via Palou, Stanford, CA 94305-4075, USA
- These authors contributed equally to this work
| | - Natesh Parashurama
- Molecular Imaging Program at Stanford, Departments of Radiology and Bioengineering, Bio-X Program, Stanford University, Stanford, CA 94305, USA
- These authors contributed equally to this work
| | - David B. Barkin
- Texas Instruments, 2900 Semiconductor Driver, Santa Clara, CA 95052, USA
| | - Bruce A. Wooley
- Department of Electrical Engineering, Stanford University, 420 Via Palou, Stanford, CA 94305-4075, USA
| | - Sanjiv S. Gambhir
- Molecular Imaging Program at Stanford, Departments of Radiology and Bioengineering, Bio-X Program, Stanford University, Stanford, CA 94305, USA
| | - James S. Harris
- Department of Electrical Engineering, Stanford University, 420 Via Palou, Stanford, CA 94305-4075, USA
| | - Ofer Levi
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, 164 College Street, Toronto, Ontario, M5S 3G9,Canada
- The Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King's College Road, Toronto, Ontario, M5S 3G4, Canada
| |
Collapse
|
9
|
Osman A, Park JH, Dickensheets D, Platisa J, Culurciello E, Pieribone VA. Design constraints for mobile, high-speed fluorescence brain imaging in awake animals. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2012; 6:446-53. [PMID: 23853231 DOI: 10.1109/tbcas.2012.2226174] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
In this paper we present a fully self-contained imaging instrument (30 mm overall length) that is capable of recording high speed and detect relatively small fluorescent signals (0.1% ΔF/F) from brain tissues potentially containing genetically-encoded sensors or dyes. This device potentially enables the study of neuronal activity in awake and mobile animals during natural behaviors without the stress and suppression of anesthesia and restraint. The device is a fully self-contained illumination system, wide field fluorescence microscope (~ 4.8 mm² FOV-25 um lateral resolution-1.8 × magnification-0.39 NA) and CMOS image sensor (32 × 32). The total weight of the system is 10 g and is capable of imaging up to 900 fps. We present voltage dye RH1692 experiments using the system to study the somatosensory cortex of mice during whisker movements using an air puff.
Collapse
Affiliation(s)
- Ahmad Osman
- The John B. Pierce Laboratory, New Haven, CT 06511, USA.
| | | | | | | | | | | |
Collapse
|
10
|
Senarathna J, Murari K, Etienne-Cummings R, Thakor NV. A miniaturized platform for laser speckle contrast imaging. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2012; 6:437-45. [PMID: 23853230 DOI: 10.1109/tbcas.2012.2218106] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Imaging the brain in animal models enables scientists to unravel new biological insights. Despite critical advancements in recent years, most laboratory imaging techniques comprise of bulky bench top apparatus that require the imaged animals to be anesthetized and immobilized. Thus, animals are imaged in their non-native state severely restricting the scope of behavioral experiments. To address this gap, we report a miniaturized microscope that can be mounted on a rat's head for imaging in awake and unrestrained conditions. The microscope uses laser speckle contrast imaging (LSCI), a high resolution yet wide field imaging modality for imaging blood vessels and perfusion. Design details of both the image formation and acquisition modules are presented. A Monte Carlo simulation was used to estimate the depth of tissue penetration achievable by the imaging system while the produced speckle Airy disc patterns were simulated using Fresnel's diffraction theory. The microscope system weighs only 7 g and occupies less than 5 cm³ and was successfully used to generate proof of concept LSCI images of rat brain vasculature. We validated the utility of the head-mountable system in an awake rat brain model by confirming no impairment to the rat's native behavior.
Collapse
Affiliation(s)
- Janaka Senarathna
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, USA.
| | | | | | | |
Collapse
|
11
|
Affiliation(s)
- Nitish V Thakor
- Department of Biomedical Engineering, The Johns Hopkins University, Baltimore, MD 21205, USA.
| |
Collapse
|
12
|
Ghosh KK, Burns LD, Cocker ED, Nimmerjahn A, Ziv Y, Gamal AE, Schnitzer MJ. Miniaturized integration of a fluorescence microscope. Nat Methods 2011; 8:871-8. [PMID: 21909102 PMCID: PMC3810311 DOI: 10.1038/nmeth.1694] [Citation(s) in RCA: 650] [Impact Index Per Article: 50.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2010] [Accepted: 08/02/2011] [Indexed: 12/11/2022]
Abstract
The light microscope is traditionally an instrument of substantial size and expense. Its miniaturized integration would enable many new applications based on mass-producible, tiny microscopes. Key prospective usages include brain imaging in behaving animals for relating cellular dynamics to animal behavior. Here we introduce a miniature (1.9 g) integrated fluorescence microscope made from mass-producible parts, including a semiconductor light source and sensor. This device enables high-speed cellular imaging across ∼0.5 mm2 areas in active mice. This capability allowed concurrent tracking of Ca2+ spiking in >200 Purkinje neurons across nine cerebellar microzones. During mouse locomotion, individual microzones exhibited large-scale, synchronized Ca2+ spiking. This is a mesoscopic neural dynamic missed by prior techniques for studying the brain at other length scales. Overall, the integrated microscope is a potentially transformative technology that permits distribution to many animals and enables diverse usages, such as portable diagnostics or microscope arrays for large-scale screens.
Collapse
Affiliation(s)
- Kunal K Ghosh
- David Packard Electrical Engineering Building, Stanford University, Stanford, California, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Park JH, Platisa J, Verhagen JV, Gautam SH, Osman A, Kim D, Pieribone VA, Culurciello E. Head-mountable high speed camera for optical neural recording. J Neurosci Methods 2011; 201:290-5. [PMID: 21763348 DOI: 10.1016/j.jneumeth.2011.06.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2011] [Revised: 06/14/2011] [Accepted: 06/23/2011] [Indexed: 10/18/2022]
Abstract
We report a head-mountable CMOS camera for recording rapid neuronal activity in freely moving rodents using fluorescent activity reporters. This small, lightweight camera is capable of detecting small changes in light intensity (0.2% ΔI/I) at 500fps. The camera has a resolution of 32×32, sensitivity of 0.62V/lxs, conversion gain of 0.52μV/e(-) and well capacity of 2.1Me(-). The camera, containing intensity offset subtraction circuitry within the imaging chip, is part of a miniaturized epi-fluorescent microscope and represents a first generation, mobile scientific-grade, physiology imaging camera.
Collapse
Affiliation(s)
- Joon Hyuk Park
- School of Engineering and Applied Science, Yale University, New Haven, CT 06520, USA
| | | | | | | | | | | | | | | |
Collapse
|