1
|
Hong R, Wu Z, Peng K, Zhang J, He Y, Zhang Z, Gao Y, Jin Y, Su X, Zhi H, Guan Q, Pan L, Jin L. Kinect-based objective assessment of the acute levodopa challenge test in parkinsonism: a feasibility study. Neurol Sci 2024; 45:2661-2670. [PMID: 38183553 DOI: 10.1007/s10072-023-07296-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 12/28/2023] [Indexed: 01/08/2024]
Abstract
INTRODUCTION The acute levodopa challenge test (ALCT) is an important and valuable examination but there are still some shortcomings with it. We aimed to objectively assess ALCT based on a depth camera and filter out the best indicators. METHODS Fifty-nine individuals with parkinsonism completed ALCT and the improvement rate (IR, which indicates the change in value before and after levodopa administration) of the Movement Disorder Society-Sponsored Revision of the Unified Parkinson's Disease Rating Scale part III (MDS-UPDRS III) was calculated. The kinematic features of the patients' movements in both the OFF and ON states were collected with an Azure Kinect depth camera. RESULTS The IR of MDS-UPDRS III was significantly correlated with the IRs of many kinematic features for arising from a chair, pronation-supination movements of the hand, finger tapping, toe tapping, leg agility, and gait (rs = - 0.277 ~ - 0.672, P < 0.05). Moderate to high discriminative values were found in the selected features in identifying a clinically significant response to levodopa with sensitivity, specificity, and area under the curve (AUC) in the range of 50-100%, 47.22%-97.22%, and 0.673-0.915, respectively. The resulting classifier combining kinematic features of toe tapping showed an excellent performance with an AUC of 0.966 (95% CI = 0.922-1.000, P < 0.001). The optimal cut-off value was 21.24% with sensitivity and specificity of 94.44% and 87.18%, respectively. CONCLUSION This study demonstrated the feasibility of measuring the effect of levodopa and objectively assessing ALCT based on kinematic data derived from an Azure Kinect-based system.
Collapse
Affiliation(s)
- Ronghua Hong
- Department of Neurology and Neurological Rehabilitation, Shanghai Disabled Persons' Federation Key Laboratory of Intelligent Rehabilitation Assistive Devices and Technologies, School of Medicine, Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Tongji University, Shanghai, China
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Zhuang Wu
- Department of Neurology and Neurological Rehabilitation, Shanghai Disabled Persons' Federation Key Laboratory of Intelligent Rehabilitation Assistive Devices and Technologies, School of Medicine, Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Tongji University, Shanghai, China
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Kangwen Peng
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Jingxing Zhang
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Yijing He
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Zhuoyu Zhang
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Yichen Gao
- IFLYTEK Suzhou Research Institute, Suzhou, China
| | - Yue Jin
- IFLYTEK Suzhou Research Institute, Suzhou, China
| | - Xiaoyun Su
- IFLYTEK Suzhou Research Institute, Suzhou, China
| | - Hongping Zhi
- IFLYTEK Suzhou Research Institute, Suzhou, China
| | - Qiang Guan
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China
| | - Lizhen Pan
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China.
| | - Lingjing Jin
- Department of Neurology and Neurological Rehabilitation, Shanghai Disabled Persons' Federation Key Laboratory of Intelligent Rehabilitation Assistive Devices and Technologies, School of Medicine, Shanghai Yangzhi Rehabilitation Hospital (Shanghai Sunshine Rehabilitation Center), Tongji University, Shanghai, China.
- Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Department of Neurology, School of Medicine, Neurotoxin Research CenterTongji HospitalTongji University, Shanghai, China.
- Collaborative Innovation Center for Brain Science, Tongji University, Shanghai, China.
| |
Collapse
|
2
|
Volpes G, Valenti S, Genova G, Barà C, Parisi A, Faes L, Busacca A, Pernice R. Wearable Ring-Shaped Biomedical Device for Physiological Monitoring through Finger-Based Acquisition of Electrocardiographic, Photoplethysmographic, and Galvanic Skin Response Signals: Design and Preliminary Measurements. BIOSENSORS 2024; 14:205. [PMID: 38667198 PMCID: PMC11048376 DOI: 10.3390/bios14040205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2024] [Revised: 04/12/2024] [Accepted: 04/18/2024] [Indexed: 04/28/2024]
Abstract
Wearable health devices (WHDs) are rapidly gaining ground in the biomedical field due to their ability to monitor the individual physiological state in everyday life scenarios, while providing a comfortable wear experience. This study introduces a novel wearable biomedical device capable of synchronously acquiring electrocardiographic (ECG), photoplethysmographic (PPG), galvanic skin response (GSR) and motion signals. The device has been specifically designed to be worn on a finger, enabling the acquisition of all biosignals directly on the fingertips, offering the significant advantage of being very comfortable and easy to be employed by the users. The simultaneous acquisition of different biosignals allows the extraction of important physiological indices, such as heart rate (HR) and its variability (HRV), pulse arrival time (PAT), GSR level, blood oxygenation level (SpO2), and respiratory rate, as well as motion detection, enabling the assessment of physiological states, together with the detection of potential physical and mental stress conditions. Preliminary measurements have been conducted on healthy subjects using a measurement protocol consisting of resting states (i.e., SUPINE and SIT) alternated with physiological stress conditions (i.e., STAND and WALK). Statistical analyses have been carried out among the distributions of the physiological indices extracted in time, frequency, and information domains, evaluated under different physiological conditions. The results of our analyses demonstrate the capability of the device to detect changes between rest and stress conditions, thereby encouraging its use for assessing individuals' physiological state. Furthermore, the possibility of performing synchronous acquisitions of PPG and ECG signals has allowed us to compare HRV and pulse rate variability (PRV) indices, so as to corroborate the reliability of PRV analysis under stationary physical conditions. Finally, the study confirms the already known limitations of wearable devices during physical activities, suggesting the use of algorithms for motion artifact correction.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Riccardo Pernice
- Department of Engineering, University of Palermo, Viale delle Scienze, Building 9, 90128 Palermo, Italy; (G.V.); (S.V.); (G.G.); (C.B.); (A.P.); (L.F.); (A.B.)
| |
Collapse
|
3
|
Anderson K, Morrice-West AV, Walmsley EA, Fisher AD, Whitton RC, Hitchens PL. Validation of inertial measurement units to detect and predict horse behaviour while stabled. Equine Vet J 2023; 55:1128-1138. [PMID: 36537838 DOI: 10.1111/evj.13909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 12/01/2022] [Indexed: 12/24/2022]
Abstract
BACKGROUND Musculoskeletal injuries are observed in Thoroughbred racehorses and may become catastrophic. Currently, there are limited methods for early detection of such injuries. Most injuries develop gradually due to accumulated damage, providing the opportunity for early detection. Horses experiencing pain or lameness may exhibit changes in behaviour so the development of an objective, real-time system monitoring horse behaviour may enable detection of bone injuries before catastrophic failure. OBJECTIVES To determine whether intensive observational methods of assessing horse behaviour can be replaced by use of inertial measurement units (IMUs). STUDY DESIGN Validation study assessing IMU use against video observation. METHODS Six hospitalised Thoroughbreds (algorithm training data) and 19 Thoroughbred racehorses in-training (algorithm testing data) were equipped with an IMU placed on the lateral side of both forelimbs (left fore, LF; right fore, RF) and monitored in a stable for 4 h. An algorithm was developed to classify behaviour and then validated against video recordings. RESULTS Standing was the most prevalent behaviour (LF 88.8%, 95% confidence interval [CI] 88.7-89.0; RF 88.5%, 95% CI 88.4-88.7). IMU classification of recumbent and standing activities showed excellent agreement (sensitivity) with video observation (>98%). This was followed by stepping (LF 89.4%, RF 85.5%) then weight-shifting (LF 54.3%, RF 61.5%). Predictions from the algorithm showed misclassification of 2.5% (LF 5500/225 352, RF 5218/210 170). Excluding standing, misclassification was 6.8% (1705/25 158) and 7.5% (1812/24 077) for the left and right forelimbs, respectively, with pawing and weight-shifting most frequently misclassified. MAIN LIMITATIONS Increasing the number of horses and types of behaviours observed may improve predictions. CONCLUSIONS IMUs displayed a high sensitivity to movement on a small number of horses, and with further validation they have the potential to effectively monitor behaviour of racehorses in training. However, more sensitive methods may be needed to validate the classification of weight-shifting behaviour. Future studies should evaluate the association between each behaviour and musculoskeletal injury.
Collapse
Affiliation(s)
- Katrina Anderson
- Equine Lameness and Imaging Centre, Melbourne Veterinary School, University of Melbourne, Werribee, Victoria, Australia
| | - Ashleigh V Morrice-West
- Equine Lameness and Imaging Centre, Melbourne Veterinary School, University of Melbourne, Werribee, Victoria, Australia
| | - Elizabeth A Walmsley
- Equine Lameness and Imaging Centre, Melbourne Veterinary School, University of Melbourne, Werribee, Victoria, Australia
| | - Andrew D Fisher
- Animal Welfare Science Centre, Faculty of Veterinary and Agricultural Sciences, University of Melbourne, Parkville, Victoria, Australia
| | - R Chris Whitton
- Equine Lameness and Imaging Centre, Melbourne Veterinary School, University of Melbourne, Werribee, Victoria, Australia
| | - Peta L Hitchens
- Equine Lameness and Imaging Centre, Melbourne Veterinary School, University of Melbourne, Werribee, Victoria, Australia
| |
Collapse
|
4
|
Zhao H, Cao J, Xie J, Liao WH, Lei Y, Cao H, Qu Q, Bowen C. Wearable sensors and features for diagnosis of neurodegenerative diseases: A systematic review. Digit Health 2023; 9:20552076231173569. [PMID: 37214662 PMCID: PMC10192816 DOI: 10.1177/20552076231173569] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Accepted: 04/17/2023] [Indexed: 05/24/2023] Open
Abstract
Objective Neurodegenerative diseases affect millions of families around the world, while various wearable sensors and corresponding data analysis can be of great support for clinical diagnosis and health assessment. This systematic review aims to provide a comprehensive overview of the existing research that uses wearable sensors and features for the diagnosis of neurodegenerative diseases. Methods A systematic review was conducted of studies published between 2015 and 2022 in major scientific databases such as Web of Science, Google Scholar, PubMed, and Scopes. The obtained studies were analyzed and organized into the process of diagnosis: wearable sensors, feature extraction, and feature selection. Results The search led to 171 eligible studies included in this overview. Wearable sensors such as force sensors, inertial sensors, electromyography, electroencephalography, acoustic sensors, optical fiber sensors, and global positioning systems were employed to monitor and diagnose neurodegenerative diseases. Various features including physical features, statistical features, nonlinear features, and features from the network can be extracted from these wearable sensors, and the alteration of features toward neurodegenerative diseases was illustrated. Moreover, different kinds of feature selection methods such as filter, wrapper, and embedded methods help to find the distinctive indicator of the diseases and benefit to a better diagnosis performance. Conclusions This systematic review enables a comprehensive understanding of wearable sensors and features for the diagnosis of neurodegenerative diseases.
Collapse
Affiliation(s)
- Huan Zhao
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi'an, P.R. China
| | - Junyi Cao
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi'an, P.R. China
| | - Junxiao Xie
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi'an, P.R. China
| | - Wei-Hsin Liao
- Department of Mechanical and Automation
Engineering, The Chinese University of Hong
Kong, Shatin, N.T., Hong Kong, China
| | - Yaguo Lei
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi'an, P.R. China
| | - Hongmei Cao
- Department of Neurology, The First
Affiliated Hospital of Xi’an Jiaotong University, Xi’an, P.R. China
| | - Qiumin Qu
- Department of Neurology, The First
Affiliated Hospital of Xi’an Jiaotong University, Xi’an, P.R. China
| | - Chris Bowen
- Department of Mechanical Engineering, University of Bath, Bath, UK
| |
Collapse
|
5
|
Guo CC, Chiesa PA, de Moor C, Fazeli MS, Schofield T, Hofer K, Belachew S, Scotland A. Digital Devices for Assessing Motor Functions in Mobility-Impaired and Healthy Populations: Systematic Literature Review. J Med Internet Res 2022; 24:e37683. [DOI: 10.2196/37683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 07/18/2022] [Accepted: 10/11/2022] [Indexed: 11/22/2022] Open
Abstract
Background
With the advent of smart sensing technology, mobile and wearable devices can provide continuous and objective monitoring and assessment of motor function outcomes.
Objective
We aimed to describe the existing scientific literature on wearable and mobile technologies that are being used or tested for assessing motor functions in mobility-impaired and healthy adults and to evaluate the degree to which these devices provide clinically valid measures of motor function in these populations.
Methods
A systematic literature review was conducted by searching Embase, MEDLINE, CENTRAL (January 1, 2015, to June 24, 2020), the United States and European Union clinical trial registries, and the United States Food and Drug Administration website using predefined study selection criteria. Study selection, data extraction, and quality assessment were performed by 2 independent reviewers.
Results
A total of 91 publications representing 87 unique studies were included. The most represented clinical conditions were Parkinson disease (n=51 studies), followed by stroke (n=5), Huntington disease (n=5), and multiple sclerosis (n=2). A total of 42 motion-detecting devices were identified, and the majority (n=27, 64%) were created for the purpose of health care–related data collection, although approximately 25% were personal electronic devices (eg, smartphones and watches) and 11% were entertainment consoles (eg, Microsoft Kinect or Xbox and Nintendo Wii). The primary motion outcomes were related to gait (n=30), gross motor movements (n=25), and fine motor movements (n=23). As a group, sensor-derived motion data showed a mean sensitivity of 0.83 (SD 7.27), a mean specificity of 0.84 (SD 15.40), a mean accuracy of 0.90 (SD 5.87) in discriminating between diseased individuals and healthy controls, and a mean Pearson r validity coefficient of 0.52 (SD 0.22) relative to clinical measures. We did not find significant differences in the degree of validity between in-laboratory and at-home sensor-based assessments nor between device class (ie, health care–related device, personal electronic devices, and entertainment consoles).
Conclusions
Sensor-derived motion data can be leveraged to classify and quantify disease status for a variety of neurological conditions. However, most of the recent research on digital clinical measures is derived from proof-of-concept studies with considerable variation in methodological approaches, and much of the reviewed literature has focused on clinical validation, with less than one-quarter of the studies performing analytical validation. Overall, future research is crucially needed to further consolidate that sensor-derived motion data may lead to the development of robust and transformative digital measurements intended to predict, diagnose, and quantify neurological disease state and its longitudinal change.
Collapse
|
6
|
Ricci M, Lazzaro GD, Errico V, Pisani A, Giannini F, Saggio G. The impact of wearable electronics in assessing the effectiveness of levodopa treatment in Parkinsons disease. IEEE J Biomed Health Inform 2022; 26:2920-2928. [PMID: 35316198 DOI: 10.1109/jbhi.2022.3160103] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
OBJECTIVE In order to evaluate Parkinson disease patients response to therapeutic interventions, sources of information are mainly patient reports and clinicians assessment of motor functions. However, these sources can suffer from patients subjectivity and from inter/intra raters score variability. Our work aimed at determining the impact of wearable electronics and data analysis in objectifying the effectiveness of levodopa treatment. METHODS Seven motor tasks performed by thirty-six patients were measured by wearable electronics and related data were analyzed. This was at the time of therapy initiation (T0), and repeated after six (T1) and 12 months (T2). Wearable electronics consisted of inertial measurement units each equipped with 3-axis accelerometer and 3-axis gyroscope, while data analysis of ANOVA and Pearson correlation algorithms, in addition to a support vector machine (SVM) classification. RESULTS According to our findings, levodopa-based therapy alters the patients conditions in general, ameliorating something (e.g. bradykinesia), leaving unchanged others (e.g. tremor), but with poor correlation to the levodopa dose. CONCLUSION A technology-based approach can objectively assess levodopa-based therapy effectiveness. SIGNIFICANCE Novel devices can improve the accuracy of the assessment of motor function, by integrating the clinical evaluation and patient reports.
Collapse
|
7
|
Exley T, Moudy S, Patterson RM, Kim J, Albert MV. Predicting UPDRS Motor Symptoms in Individuals with Parkinsons Disease from Force Plates Using Machine Learning. IEEE J Biomed Health Inform 2022; 26:3486-3494. [PMID: 35259121 DOI: 10.1109/jbhi.2022.3157518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Parkinsons disease (PD) is a neurodegenerative disease that affects motor abilities with increasing severity as the disease progresses. Traditional methods for diagnosing PD include a section where a trained specialist scores qualitative symptoms using the motor subscale of the Unified Parkinsons Disease Rating Scale (UPDRS-III). The aim of this feasibility study was twofold. First, to evaluate quiet standing as an additional, out-of-clinic, objective feature to predict UPDRS-III subscores related to motor symptom severity; and second, to use quiet standing to detect the presence of motor symptoms. Force plate data were collected from 42 PD patients and 43 healthy controls during quiet standing (a task involving standing still with eyes open and closed) as a feasible task in clinics. Predicting each subscore of the UPDRS-III could aid in identifying progression of PD and provide specialists additional tools to make an informed diagnosis. Random Forest feature importance indicated that features correlated with range of center of pressure (i.e. the medial-lateral and anterior-posterior sway) were most useful in the prediction of the top PD prediction subscores of postural stability (r = 0.599; p = 0.014), hand tremor of the left hand (r = 0.650; p = 0.015), and tremor at rest of the left upper extremity (r = 0.703; p = 0.016). Quiet standing can detect body bradykinesia (AUC-ROC = 0.924) and postural stability (AUC-ROC = 0.967) with high predictability. Although there are limited data, these results should be used as a feasibility study that evaluates the predictability of individual UPDRS-III subscores using quiet standing data.
Collapse
|
8
|
Su G, Lin B, Yin J, Luo W, Xu R, Xu J, Dong K. Detection of hypomimia in patients with Parkinson's disease via smile videos. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1307. [PMID: 34532444 PMCID: PMC8422154 DOI: 10.21037/atm-21-3457] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 08/20/2021] [Indexed: 11/25/2022]
Abstract
Background Parkinson’s disease (PD) is a neurodegenerative disease characterized by the impairment of facial expression, known as hypomimia. Hypomimia has serious impacts on patients’ ability to communicate, and it is difficult to detect at early stages of the disease. Furthermore, due to bradykinesia or other reasons, it is inconvenient for PD patients to visit the hospital. Therefore, it is appealing to develop an auxiliary diagnostic method that remotely detects hypomimia. Methods We proposed an automatic detection system for Parkinson’s hypomimia based on facial expressions (DSPH-FE). DSPH-FE provides a convenient remote service for those who potentially suffer from hypomimia and only requires patients to input their facial videos. Specifically, patients can detect hypomimia through two aspects: geometric features and texture features. Geometric features focus on visually representing structures of facial muscles. Facial expression factors (FEFs) are used as the first metric to quantify the current activation state of the facial muscles. Facial expression change factors (FECFs) are subsequently used as the second metric to calculate the moving trajectories of the activation states in the videos. Geometric features primarily concentrate on spatial information, with little involvement of temporal information. Thus, the extended histogram of oriented gradients (HOG) algorithm is introduced. This algorithm can extract texture features within multiple continuous frames and incorporate the temporal information into the features. Finally, these features are applied to four machine learning algorithms to model the relationship between these features and hypomimia. Results The DSPH-FE detection system achieved the best performance when concatenating geometric features and texture features, resulting in a F1 score of 0.9997. The best F1 scores achieved with geometric features and texture features were 0.8286 and 0.9446, respectively. This indicated that both geometric features and texture features have an ability to predict hypomimia, and demonstrated that temporal information can boost the model performance. Thus, DSPH-FE is an effective supportive tool in the medical management of PD patients. Conclusions Comprehensive experiments demonstrated that proposed features fit well with real-world videos and are beneficial in the clinical diagnosis of hypomimia. In particular, hypomimia had a greater impact on eyes and mouths when patients are smiling.
Collapse
Affiliation(s)
- Ge Su
- College of Computer Science and Technology, Zhejiang University, Hangzhou, China
| | - Bo Lin
- College of Computer Science and Technology, Zhejiang University, Hangzhou, China
| | - Jianwei Yin
- College of Computer Science and Technology, Zhejiang University, Hangzhou, China
| | - Wei Luo
- Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Renjun Xu
- Center for Data Science, Zhejiang University, Hangzhou, China
| | - Jie Xu
- Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China
| | - Kexiong Dong
- Technical Department, Hangzhou Healink Technology Corporation Limited, Hangzhou, China
| |
Collapse
|
9
|
Alasti H. Communication-Efficient Tracking of Unknown, Spatially Correlated Signals in Ad-Hoc Wireless Sensor Networks: Two Machine Learning Approaches. SENSORS (BASEL, SWITZERLAND) 2021; 21:5175. [PMID: 34372411 PMCID: PMC8347045 DOI: 10.3390/s21155175] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/27/2021] [Accepted: 07/28/2021] [Indexed: 11/16/2022]
Abstract
A low-cost machine learning (ML) algorithm is proposed and discussed for spatial tracking of unknown, correlated signals in localized, ad-hoc wireless sensor networks. Each sensor is modeled as one neuron and a selected subset of these neurons are called to identify the spatial signal. The algorithm is implemented in two phases of spatial modeling and spatial tracking. The spatial signal is modeled using its M iso-contour lines at levels {ℓj}j=1M and those sensors that their sensor observations are in Δ margin of any of these levels report their sensor observations to the fusion center (FC) for spatial signal reconstruction. In spatial modeling phase, the number of these contour lines, their levels and a proper Δ are identified. In this phase, the algorithm may either use adaptive-weight stochastic gradient or scaled stochastic gradient method to select a proper Δ. Additive white Gaussian noise (AWGN) with zero mean is assumed along with the sensor observations. To reduce the observation noise's effect, each sensor applies moving average filter on its observation to drastically reduce the effect of noise. The modeling performance, the cost and the convergence of the algorithm are discussed based on extensive computer simulations and reasoning. The algorithm is proposed for climate and environmental monitoring. In this paper, the percentage of wireless sensors that initiate a communication attempt is assumed as cost. The performance evaluation results show that the proposed spatial tracking approach is low-cost and can model the spatial signal over time with the same performance as that of spatial modeling.
Collapse
Affiliation(s)
- Hadi Alasti
- School of Polytechnic, College of Engineering, Purdue University Fort Wayne, Fort Wayne, IN 46805, USA
| |
Collapse
|
10
|
Borzi L, Varrecchia M, Sibille S, Olmo G, Artusi CA, Fabbri M, Rizzone MG, Romagnolo A, Zibetti M, Lopiano L. Smartphone-Based Estimation of Item 3.8 of the MDS-UPDRS-III for Assessing Leg Agility in People With Parkinson's Disease. IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY 2020; 1:140-147. [PMID: 35402940 PMCID: PMC8975117 DOI: 10.1109/ojemb.2020.2993463] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 04/17/2020] [Accepted: 05/04/2020] [Indexed: 11/09/2022] Open
Abstract
Goal: In this paper we investigated the use of smartphone sensors and Artificial Intelligence techniques for the automatic quantification of the MDS-UPDRS-Part III Leg Agility (LA) task, representative of lower limb bradykinesia. Methods: We collected inertial data from 93 PD subjects. Four expert neurologists provided clinical evaluations. We employed a novel Artificial Neural Network approach in order to get a continuous output, going beyond the MDS-UPDRS score discretization. Results: We found a Pearson correlation of 0.92 between algorithm output and average clinical score, compared to an inter-rater agreement index of 0.88. Furthermore, the classification error was less than 0.5 scale point in about 80% cases. Conclusions: We proposed an objective and reliable tool for the automatic quantification of the MDS-UPDRS Leg Agility task. In perspective, this tool is part of a larger monitoring program to be carried out during activities of daily living, and managed by the patients themselves.
Collapse
Affiliation(s)
- Luigi Borzi
- Department of Control and Computing EngineeringPolitecnico di Torino 10138 Torino Italy
| | - Marilena Varrecchia
- Department of Control and Computing EngineeringPolitecnico di Torino 10138 Torino Italy
| | - Stefano Sibille
- Department of Control and Computing EngineeringPolitecnico di Torino 10138 Torino Italy
| | - Gabriella Olmo
- Department of Control and Computing EngineeringPolitecnico di Torino 10138 Torino Italy
| | - Carlo Alberto Artusi
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| | - Margherita Fabbri
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| | - Mario Giorgio Rizzone
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| | - Alberto Romagnolo
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| | - Maurizio Zibetti
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| | - Leonardo Lopiano
- Department of Neuroscience "Rita Levi Montalcini,"University of Turin 10124 Torino Italy
| |
Collapse
|