Henry B, Merz M, Hoang H, Abdulkarim G, Wosik J, Schoettker P. Cuffless Blood Pressure in clinical practice: challenges, opportunities and current limits. Blood Press 2024; 33:2304190. [PMID: 38245864 DOI: 10.1080/08037051.2024.2304190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 01/07/2024] [Indexed: 01/22/2024]
Abstract
Background: Cuffless blood pressure measurement technologies have attracted significant attention for their potential to transform cardiovascular monitoring.Methods: This updated narrative review thoroughly examines the challenges, opportunities, and limitations associated with the implementation of cuffless blood pressure monitoring systems.Results: Diverse technologies, including photoplethysmography, tonometry, and ECG analysis, enable cuffless blood pressure measurement and are integrated into devices like smartphones and smartwatches. Signal processing emerges as a critical aspect, dictating the accuracy and reliability of readings. Despite its potential, the integration of cuffless technologies into clinical practice faces obstacles, including the need to address concerns related to accuracy, calibration, and standardization across diverse devices and patient populations. The development of robust algorithms to mitigate artifacts and environmental disturbances is essential for extracting clear physiological signals. Based on extensive research, this review emphasizes the necessity for standardized protocols, validation studies, and regulatory frameworks to ensure the reliability and safety of cuffless blood pressure monitoring devices and their implementation in mainstream medical practice. Interdisciplinary collaborations between engineers, clinicians, and regulatory bodies are crucial to address technical, clinical, and regulatory complexities during implementation. In conclusion, while cuffless blood pressure monitoring holds immense potential to transform cardiovascular care. The resolution of existing challenges and the establishment of rigorous standards are imperative for its seamless incorporation into routine clinical practice.Conclusion: The emergence of these new technologies shifts the paradigm of cardiovascular health management, presenting a new possibility for non-invasive continuous and dynamic monitoring. The concept of cuffless blood pressure measurement is viable and more finely tuned devices are expected to enter the market, which could redefine our understanding of blood pressure and hypertension.
Collapse
Affiliation(s)
- Benoit Henry
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Maxime Merz
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Harry Hoang
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ghaith Abdulkarim
- Neuro-Informatics Laboratory, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Jedrek Wosik
- Department of Medicine, Duke University School of Medicine, Durham, North Carolina
| | - Patrick Schoettker
- Service of Anesthesiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
2
|
Rajput V, Mulay P. Fact Finding Instructor-based Clustering Technique for BP Estimation using Human Speech Signals. Comput Methods Biomech Biomed Engin 2024; 27:2145-2160. [PMID: 37929760 DOI: 10.1080/10255842.2023.2273203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 04/06/2023] [Accepted: 10/14/2023] [Indexed: 11/07/2023]
Abstract
Blood Pressure (BP) is considered an essential factor that provides information regarding cardiovascular function. Regular monitoring of the BP is required for proper healthcare maintenance that avoids the high risk of life due to high and low BP. Several methods were devised for the estimation of BP, but the estimation accuracy is still a challenging task. Hence this research introduces an efficient BP estimation technique using the Fact Finding Instructor (FFI) based clustering method by considering the speech signal of the patients. An efficient BP extraction technique is introduced using the FFI Optimization algorithm an integration of the mannerism of the fact finder that identifies the suspect who commits the criminal offense and, with the instructor with good knowledge, these make the trainee more efficient. The detection and suspect's arrest contain two phases, the fact-finding phase and the chasing phase. Initially, the speech signal is collected from the database and pre-processed for removing noise and artifacts. Then feature extraction is used for the minimization of the computation overhead that generates a feature vector. The clustering of BP is employed with the k-means clustering algorithm and the proposed FFI optimization algorithm. The FFI Optimization algorithm provides a fast convergence rate due to the fact-finding phase and provides accurate detection of the suspect's location along with that the clustering of classes of patients' BP by considering the feature of the speech signal. The clusters formed using the FFI optimization algorithm are combined with the K-means clustering, by multiplying the clusters the BP estimation is implemented on three criteria Low BP, Normal, and, High BP. Finally, the output generated by both the clustering operations is multiplied together for the estimation of the BP. The performance of the proposed method is evaluated using the metrics like Davies Bouldin score, Homogeneity score, Completeness score, Jacquard Similarity score, Silhouette score, and Dunn's Index which acquired the improvement rate of 0.98, 0.96, 0.96, 0.98, 0.95, and 0.98 for training percentage 90, respectively to the existing Teaching Learning Based Optimization(TLBO) clustering technique.
Collapse
Affiliation(s)
- Vaishali Rajput
- Symbiosis Institute of Technology, Symbiosis International (Deemed University), Pune, India
- Vishwakarma Institute of Technology, Pune, India
| | - Preeti Mulay
- Vishwakarma Institute of Technology, Pune, India
| |
Collapse
|
3
|
Cen Y, Luo J, Wang H, Chen L, Zhu X, Guo S, Luo J. OVAR-BPnet: A General Pulse Wave Deep Learning Approach for Cuffless Blood Pressure Measurement. IEEE J Biomed Health Inform 2024; 28:5829-5841. [PMID: 38963748 DOI: 10.1109/jbhi.2024.3423461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/06/2024]
Abstract
Pulse wave analysis, a non-invasive and cuff-less approach, holds promise for blood pressure (BP) measurement in precision medicine. In recent years, pulse wave learning for BP estimation has undergone extensive scrutiny. However, prevailing methods still encounter challenges in grasping comprehensive features from pulse waves and generalizing these insights for precise BP estimation. In this study, we propose a general pulse wave deep learning (PWDL) approach for BP estimation, introduc-ing the OVAR-BPnet model to powerfully capture intricate pulse wave features and showcasing its effectiveness on multiple types of pulse waves. The approach involves constructing population pulse waves and employing a model comprising an omni-scale convolution subnet, a Vision Transformer subnet, and a multilayer perceptron subnet. This design enables the learning of both single-period and multi-period waveform features from multiple subjects. Additionally, the approach employs a data augmentation strategy to enhance the morphological features of pulse waves and devise a label sequence regularization strategy to strengthen the intrinsic relationship of the subnets' output. Notably, this is the first study to validate the performance of the deep learning approach of BP estimation on three types of pulse waves: photoplethysmography, forehead imaging photoplethysmography, and radial artery pulse pressure waveform. Experiments show that the OVAR-BPnet model has achieved advanced levels in both evaluation indicators and international evaluation criteria, demonstrating its excellent competitiveness and generalizability. The PWDL approach has the potential for widespread application in convenient and continuous BP monitoring systems.
Collapse
|
4
|
Qiu Y, Ma X, Li X, Fan S, Deng Z, Huang X. Non-Contact Blood Pressure Estimation From Radar Signals by a Stacked Deformable Convolution Network. IEEE J Biomed Health Inform 2024; 28:4553-4564. [PMID: 38743528 DOI: 10.1109/jbhi.2024.3400961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
This study introduces a contactless blood pressure monitoring approach that combines conventional radar signal processing with novel deep learning architectures. During the preprocessing phase, datasets suitable for synchronization are created by integrating Kalman filtering, multiscale bandpass filters, and a periodic extraction method in the time domain. These data comprise data on chest micro variations, encapsulating a complex array of physiological and biomedical information reflective of cardiac micromotions. The Radar-based Stacked Deformable convolution Network (RSD-Net) integrates channel and spatial self attention mechanisms within a deformable convolutional framework to enhance feature extraction from radar signals. The network architecture systematically employs deformable convolutions for initial deep feature extraction from individual signals. Subsequently, continuous blood pressure estimation is conducted using self attention mechanisms on feature map from single source coupled with multi-feature map channel attention. The performance of model is corroborated via the open-source dataset procured using a non-invasive 24 GHz six-port continuous wave radar system. The dataset, encompassing readings from 30 healthy individuals subjected to diverse conditions including rest, the Valsalva maneuver, apnea, and tilt-table examinations. It serves to substantiate the validity and resilience of the proposed method in the non-contact assessment of continuous blood pressure. Evaluation metrics reveal Pearson correlation coefficients of 0.838 for systolic and 0.797 for diastolic blood pressure predictions. The Mean Error (ME) and Standard Deviation (SD) for systolic and diastolic blood pressure measurements are -0.32 ±6.14 mmHg and -0.20 ±5.50 mmHg, respectively. The ablation study assesses the contribution of different structural components of the RSD-Net, validating their significance in the overall of model performance.
Collapse
|
5
|
Liu ZD, Li Y, Zhang YT, Zeng J, Chen ZX, Liu JK, Miao F. HGCTNet: Handcrafted Feature-Guided CNN and Transformer Network for Wearable Cuffless Blood Pressure Measurement. IEEE J Biomed Health Inform 2024; 28:3882-3894. [PMID: 38687656 DOI: 10.1109/jbhi.2024.3395445] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Biosignals collected by wearable devices, such as electrocardiogram and photoplethysmogram, exhibit redundancy and global temporal dependencies, posing a challenge in extracting discriminative features for blood pressure (BP) estimation. To address this challenge, we propose HGCTNet, a handcrafted feature-guided CNN and transformer network for cuffless BP measurement based on wearable devices. By leveraging convolutional operations and self-attention mechanisms, we design a CNN-Transformer hybrid architecture to learn features from biosignals that capture both local information and global temporal dependencies. Then, we introduce a handcrafted feature-guided attention module that utilizes handcrafted features extracted from biosignals as query vectors to eliminate redundant information within the learned features. Finally, we design a feature fusion module that integrates the learned features, handcrafted features, and demographics to enhance model performance. We validate our approach using two large wearable BP datasets: the CAS-BP dataset and the Aurora-BP dataset. Experimental results demonstrate that HGCTNet achieves an estimation error of 0.9 ± 6.5 mmHg for diastolic BP (DBP) and 0.7 ± 8.3 mmHg for systolic BP (SBP) on the CAS-BP dataset. On the Aurora-BP dataset, the corresponding errors are -0.4 ± 7.0 mmHg for DBP and -0.4 ± 8.6 mmHg for SBP. Compared to the current state-of-the-art approaches, HGCTNet reduces the mean absolute error of SBP estimation by 10.68% on the CAS-BP dataset and 9.84% on the Aurora-BP dataset. These results highlight the potential of HGCTNet in improving the performance of wearable cuffless BP measurements.
Collapse
|
6
|
Valerio A, Demarchi D, O’Flynn B, Motto Ros P, Tedesco S. Development of a Personalized Multiclass Classification Model to Detect Blood Pressure Variations Associated with Physical or Cognitive Workload. SENSORS (BASEL, SWITZERLAND) 2024; 24:3697. [PMID: 38894487 PMCID: PMC11175227 DOI: 10.3390/s24113697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 05/23/2024] [Accepted: 06/04/2024] [Indexed: 06/21/2024]
Abstract
Comprehending the regulatory mechanisms influencing blood pressure control is pivotal for continuous monitoring of this parameter. Implementing a personalized machine learning model, utilizing data-driven features, presents an opportunity to facilitate tracking blood pressure fluctuations in various conditions. In this work, data-driven photoplethysmograph features extracted from the brachial and digital arteries of 28 healthy subjects were used to feed a random forest classifier in an attempt to develop a system capable of tracking blood pressure. We evaluated the behavior of this latter classifier according to the different sizes of the training set and degrees of personalization used. Aggregated accuracy, precision, recall, and F1-score were equal to 95.1%, 95.2%, 95%, and 95.4% when 30% of a target subject's pulse waveforms were combined with five randomly selected source subjects available in the dataset. Experimental findings illustrated that incorporating a pre-training stage with data from different subjects made it viable to discern morphological distinctions in beat-to-beat pulse waveforms under conditions of cognitive or physical workload.
Collapse
Affiliation(s)
- Andrea Valerio
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy;
| | - Danilo Demarchi
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy;
| | - Brendan O’Flynn
- Tyndall National Institute, University College Cork, Lee Maltings Complex, Dyke Parade, T12R5CP Cork, Ireland; (B.O.); (S.T.)
| | - Paolo Motto Ros
- Department of Electronics and Telecommunications, Politecnico di Torino, 10129 Torino, Italy;
| | - Salvatore Tedesco
- Tyndall National Institute, University College Cork, Lee Maltings Complex, Dyke Parade, T12R5CP Cork, Ireland; (B.O.); (S.T.)
| |
Collapse
|
7
|
Tian S, Wang L, Zhu R. A flexible multimodal pulse sensor for wearable continuous blood pressure monitoring. MATERIALS HORIZONS 2024; 11:2428-2437. [PMID: 38441176 DOI: 10.1039/d3mh01999c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2024]
Abstract
Monitoring of arterial blood pressure via cuffless pulse waveform measurement at the wrist has an important clinical value for the early diagnosis and prevention of cardiovascular disease. However, accurate measurement of the radial pulse waveform is challenging owing to its subtle, wideband, and preload-dependent variation characteristics. Evidence shows that uncertainties or variations of wearing pressure and skin temperature can cause artifact signals in wrist pulse measurements, thus degrading blood pressure estimate accuracy and hindering precise clinical diagnosis. Herein, we report a flexible multisensory pulse sensor utilizing natural piezo-thermic transduction of human skin in conjunction with thin-film thermistors for the accurately measuring radial artery pulse waves with high fidelity and good anti-artifact performance. The flexible pulse sensor achieved a wide pressure measuring range (228.2 kPa), low detection limit (4 Pa), good linearity (R2 = 0.999), low hysteresis (2.45%), fast response (88 ms), and good durability and stability, thereby enabling accurate pulse measurement with high fidelity. The pulse sensor also monolithically integrated the simultaneous detections of skin temperature and wearing pressure for resisting artifact effects in pulse measurements. Through the fusion of multiple features extracted from the pulse waveform, wearing pressure, skin temperature and user's personal physical characteristics using an efficient multilayer perceptron, blood pressure is accurately estimated and good generalizability is achieved.
Collapse
Affiliation(s)
- Shuo Tian
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China.
| | - Liangqi Wang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China.
| | - Rong Zhu
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China.
| |
Collapse
|
8
|
Mohammed H, Chen HB, Li Y, Sabor N, Wang JG, Wang G. Meta-Analysis of Pulse Transition Features in Non-Invasive Blood Pressure Estimation Systems: Bridging Physiology and Engineering Perspectives. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2023; 17:1257-1281. [PMID: 38015673 DOI: 10.1109/tbcas.2023.3334960] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
The pulse transition features (PTFs), including pulse arrival time (PAT) and pulse transition time (PTT), hold significant importance in estimating non-invasive blood pressure (NIBP). However, the literature showcases considerable variations in terms of PTFs' correlation with blood pressure (BP), accuracy in NIBP estimation, and the comprehension of the relationship between PTFs and BP. This inconsistency is exemplified by the wide-ranging correlations reported across studies investigating the same feature. Furthermore, investigations comparing PAT and PTT have yielded conflicting outcomes. Additionally, PTFs have been derived from various bio-signals, capturing distinct characteristic points like the pulse's foot and peak. To address these inconsistencies, this study meticulously reviews a selection of such research endeavors while aligning them with the biological intricacies of blood pressure and the human cardiovascular system (CVS). Each study underwent evaluation, considering the specific signal acquisition locale and the corresponding recording procedure. Moreover, a comprehensive meta-analysis was conducted, yielding multiple conclusions that could significantly enhance the design and accuracy of NIBP systems. Grounded in these dual aspects, the study systematically examines PTFs in correlation with the specific study conditions and the underlying factors influencing the CVS. This approach serves as a valuable resource for researchers aiming to optimize the design of BP recording experiments, bio-signal acquisition systems, and the fine-tuning of feature engineering methodologies, ultimately advancing PTF-based NIBP estimation.
Collapse
|
9
|
Wang L, Tian S, Zhu R. A new method of continuous blood pressure monitoring using multichannel sensing signals on the wrist. MICROSYSTEMS & NANOENGINEERING 2023; 9:117. [PMID: 37744263 PMCID: PMC10511443 DOI: 10.1038/s41378-023-00590-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/06/2023] [Accepted: 07/31/2023] [Indexed: 09/26/2023]
Abstract
Hypertension is a worldwide health problem and a primary risk factor for cardiovascular disease. Continuous monitoring of blood pressure has important clinical value for the early diagnosis and prevention of cardiovascular disease. However, existing technologies for wearable continuous blood pressure monitoring are usually inaccurate, rely on subject-specific calibration and have poor generalization across individuals, which limit their practical applications. Here, we report a new blood pressure measurement method and develop an associated wearable device to implement continuous blood pressure monitoring for new subjects. The wearable device detects cardiac output and pulse waveform features through dual photoplethysmography (PPG) sensors worn on the palmar and dorsal sides of the wrist, incorporating custom-made interface sensors to detect the wearing contact pressure and skin temperature. The detected multichannel signals are fused using a machine-learning algorithm to estimate continuous blood pressure in real time. This dual PPG sensing method effectively eliminates the personal differences in PPG signals caused by different people and different wearing conditions. The proposed wearable device enables continuous blood pressure monitoring with good generalizability across individuals and demonstrates promising potential in personal health care applications.
Collapse
Affiliation(s)
- Liangqi Wang
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| | - Shuo Tian
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| | - Rong Zhu
- State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, 100084 Beijing, China
| |
Collapse
|
10
|
Liu ZD, Li Y, Zhang YT, Zeng J, Chen ZX, Cui ZW, Liu JK, Miao F. Cuffless Blood Pressure Measurement Using Smartwatches: A Large-Scale Validation Study. IEEE J Biomed Health Inform 2023; 27:4216-4227. [PMID: 37204948 DOI: 10.1109/jbhi.2023.3278168] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
This study aimed to evaluate the performance of cuffless blood pressure (BP) measurement techniques in a large and diverse cohort of participants. We enrolled 3077 participants (aged 18-75, 65.16% women, 35.91% hypertensive participants) and conducted followed-up for approximately 1 month. Electrocardiogram, pulse pressure wave, and multiwavelength photoplethysmogram signals were simultaneously recorded using smartwatches; dual-observer auscultation systolic BP (SBP) and diastolic BP (DBP) reference measurements were also obtained. Pulse transit time, traditional machine learning (TML), and deep learning (DL) models were evaluated with calibration and calibration-free strategy. TML models were developed using ridge regression, support vector machine, adaptive boosting, and random forest; while DL models using convolutional and recurrent neural networks. The best-performing calibration-based model yielded estimation errors of 1.33 ± 6.43 mmHg for DBP and 2.31 ± 9.57 mmHg for SBP in the overall population, with reduced SBP estimation errors in normotensive (1.97 ± 7.85 mmHg) and young (0.24 ± 6.61 mmHg) subpopulations. The best-performing calibration-free model had estimation errors of -0.29 ± 8.78 mmHg for DBP and -0.71 ± 13.04 mmHg for SBP. We conclude that smartwatches are effective for measuring DBP for all participants and SBP for normotensive and younger participants with calibration; performance degrades significantly for heterogeneous populations including older and hypertensive participants. The availability of cuffless BP measurement without calibration is limited in routine settings. Our study provides a large-scale benchmark for emerging investigations on cuffless BP measurement, highlighting the need to explore additional signals or principles to enhance the accuracy in large-scale heterogeneous populations.
Collapse
|
11
|
Liu W, Du S, Pang N, Zhang L, Sun G, Xiao H, Zhao Q, Xu L, Yao Y, Alastruey J, Avolio A. Central Aortic Blood Pressure Waveform Estimation with a Temporal Convolutional Network. IEEE J Biomed Health Inform 2023; 27:3622-3632. [PMID: 37079413 DOI: 10.1109/jbhi.2023.3268886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2023]
Abstract
A novel temporal convolutional network (TCN) model is utilized to reconstruct the central aortic blood pressure (aBP) waveform from the radial blood pressure waveform. The method does not need manual feature extraction as traditional transfer function approaches. The data acquired by the SphygmoCor CVMS device in 1,032 participants as a measured database and a public database of 4,374 virtual healthy subjects were used to compare the accuracy and computational cost of the TCN model with the published convolutional neural network and bi-directional long short-term memory (CNN-BiLSTM) model. The TCN model was compared with CNN-BiLSTM in the root mean square error (RMSE). The TCN model generally outperformed the existing CNN-BiLSTM model in terms of accuracy and computational cost. For the measured and public databases, the RMSE of the waveform using the TCN model was 0.55 ± 0.40 mmHg and 0.84 ± 0.29 mmHg, respectively. The training time of the TCN model was 9.63 min and 25.51 min for the entire training set; the average test time was around 1.79 ms and 8.58 ms per test pulse signal from the measured and public databases, respectively. The TCN model is accurate and fast for processing long input signals, and provides a novel method for measuring the aBP waveform. This method may contribute to the early monitoring and prevention of cardiovascular disease.
Collapse
|
12
|
Xie C, Wan C, Wang Y, Song J, Wu D, Li Y. Effects of Pulse Transit Time and Pulse Arrival Time on Cuff-less Blood Pressure Estimation: A Comparison Study with Multiple Experimental Interventions. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2023; 2023:1-4. [PMID: 38083296 DOI: 10.1109/embc40787.2023.10340548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Pulse transit time (PTT) has shown a correlation with blood pressure (BP), and it is considered as a potential marker for cuff-less BP estimation. However, pulse arrival time (PAT) including pre-ejection period (PEP) has been utilized more widely because of its convenience to acquisition and calculation. In spite of this, whether PAT can surrogate PTT has been a controversial topic for many years. In this study, we designed an experiment on 55 subjects with multiple interventions, those may cause the changes in BP and PEP. We analyzed the linear and nonlinear correlations between BP and PTT/PAT, and also assessed the performances of PTT-based and PAT-based models on tracking the BP variation. Five typical BP estimation models were used for comparison. We found that PEP could change rapidly in response to the interventions related with physical stress. Although PTT had a better linear correlation with BP, most of the PAT-based models showed more accuracy than PTT-based models in all of the interventions, especially for the calibrated models. It is suggested that PAT has the potential to predict BP, and the inclusion of PEP in the measurement of PAT is necessary.
Collapse
|
13
|
Gupta S, Singh A, Sharma A. Exploiting moving slope features of PPG derivatives for estimation of mean arterial pressure. Biomed Eng Lett 2023; 13:1-9. [PMID: 36711158 PMCID: PMC9873885 DOI: 10.1007/s13534-022-00247-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 08/24/2022] [Accepted: 09/17/2022] [Indexed: 02/01/2023] Open
Abstract
Monitoring Mean Arterial Pressure (MAP) helps calculate the arteries' flow, resistance, and pressure. It allows doctors to check how well the blood flows through our body and reaches all major organs. Photoplethysmogram technology is gaining momentum and popularity in smart wearable devices to monitor cuff-less blood pressure (BP). However, the performance reliability of the existing PPG-based BP estimation devices is still poor. Inaccuracy in estimating systolic and diastolic blood pressure leads to an overall imprecision in resultant MAP values. Hence, there is a need for robust and reliable MAP estimation algorithms. This work exploits the moving slope features of PPG contour in its first and second derivatives that directly correlate with MAP and does not require estimating systolic and diastolic blood pressure values. The proposed approach is evaluated using two different data sets (i.e., MIMIC-I and MIMIC-II) to demonstrate the robustness and reliability of the work for personalized non-invasive BP monitoring devices to estimate MAP directly. A mean absolute error of 1.28 mmHg and a standard deviation of 2.50 mmHg is obtained with MIMIC-II data-set using GridSearchCV random forest regressor that outperformed most of the existing related works.
Collapse
Affiliation(s)
| | - Anurag Singh
- IIIT Naya Raipur, Raipur, Chhattisgarh 493661 India
| | | |
Collapse
|
14
|
Mahmud S, Ibtehaz N, Khandakar A, Sohel Rahman M, JR. Gonzales A, Rahman T, Shafayet Hossain M, Sakib Abrar Hossain M, Ahasan Atick Faisal M, Fuad Abir F, Musharavati F, E. H. Chowdhury M. NABNet: A Nested Attention-guided BiConvLSTM network for a robust prediction of Blood Pressure components from reconstructed Arterial Blood Pressure waveforms using PPG and ECG signals. Biomed Signal Process Control 2023. [DOI: 10.1016/j.bspc.2022.104247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
15
|
Qin K, Huang W, Zhang T, Tang S. Machine learning and deep learning for blood pressure prediction: a methodological review from multiple perspectives. Artif Intell Rev 2022. [DOI: 10.1007/s10462-022-10353-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
16
|
Khan Mamun MMR, Sherif A. Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 10:bioengineering10010027. [PMID: 36671599 PMCID: PMC9854981 DOI: 10.3390/bioengineering10010027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 12/28/2022]
Abstract
Hypertension is a chronic condition that is one of the prominent reasons behind cardiovascular disease, brain stroke, and organ failure. Left unnoticed and untreated, the deterioration in a health condition could even result in mortality. If it can be detected early, with proper treatment, undesirable outcomes can be avoided. Until now, the gold standard is the invasive way of measuring blood pressure (BP) using a catheter. Additionally, the cuff-based and noninvasive methods are too cumbersome or inconvenient for frequent measurement of BP. With the advancement of sensor technology, signal processing techniques, and machine learning algorithms, researchers are trying to find the perfect relationships between biomedical signals and changes in BP. This paper is a literature review of the studies conducted on the cuffless noninvasive measurement of BP using biomedical signals. Relevant articles were selected using specific criteria, then traditional techniques for BP measurement were discussed along with a motivation for cuffless measurement use of biomedical signals and machine learning algorithms. The review focused on the progression of different noninvasive cuffless techniques rather than comparing performance among different studies. The literature survey concluded that the use of deep learning proved to be the most accurate among all the cuffless measurement techniques. On the other side, this accuracy has several disadvantages, such as lack of interpretability, computationally extensive, standard validation protocol, and lack of collaboration with health professionals. Additionally, the continuing work by researchers is progressing with a potential solution for these challenges. Finally, future research directions have been provided to encounter the challenges.
Collapse
Affiliation(s)
| | - Ahmed Sherif
- School of Computing Sciences and Computer Engineering, The University of Southern Mississippi, Hattiesburg, MS 39406, USA
| |
Collapse
|
17
|
Mohammed H, Wang K, Wu H, Wang G. Subject-wise model generalization through pooling and patching for regression: Application on non-invasive systolic blood pressure estimation. Comput Biol Med 2022; 151:106299. [PMID: 36423530 DOI: 10.1016/j.compbiomed.2022.106299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 10/19/2022] [Accepted: 11/06/2022] [Indexed: 11/13/2022]
Abstract
BACKGROUND Subject-wise modeling using machine learning is useful in many applications requiring low error and complexity, such as wearable medical devices. However, regression accuracy depends highly on the data available to train the model and the model's generalization ability. Adversely, the prediction error may increase severely if unknown data patterns test the model; such a model is known to be overfitted. In medicine-related applications, such as Non-Invasive Blood Pressure (NIBP) estimation, the high error renders the estimation model useless and dangerous. METHODS This paper presents a novel algorithm to handle overfitting by editing the training data to achieve generalization for subject-wise models. The pooling and patching (PaP) algorithms use a relatively short record segment of a subject as a Key-Segment (KS) to search through a larger dataset for similar subjects. Then samples taken from the matched subjects' pool records are used to patch the original subject's KS. Due to the significance of systolic blood pressure (SBP) and the complexity of its variability, non-invasive estimation of SBP from electrocardiography (ECG) and photoplethysmography (PPG) is introduced as an application to assess the algorithm. The study was performed on 2051 subjects with a wide range of age, height, weight, length, and health status. The subjects' records were taken from a large public dataset, VitalDB, which is acquired from subjects undergoing different surgeries. Finally, all the results are obtained without using other model generalization techniques. RESULTS The generalization effect of the proposed algorithm, PaP, significantly outperformed cross-validation, which is widely used in regression model generalization. Moreover, the testing results show that a KS of 200 to 2000 samples is sufficient for providing high accuracy for much longer testing data of about 12000 to 24000 samples long, which is less than %10 of the record length on average. Furthermore, compared to other works based on the same dataset, PaP provides a significantly lower mean error of -0.75 ± 5.51 mmHg, with a small training data portion of 15% over 2051 subjects.
Collapse
Affiliation(s)
- Hazem Mohammed
- Department of Micro/Nano Electronics, School of Electrical, Information, and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China; Electrical Engineering Department, Faculty of Engineering, Assuit University, Asyut, Egypt.
| | - Kai Wang
- Zhiyuan College, Shanghai Jiao Tong University, Shanghai, China
| | - Hao Wu
- College of Electronics and Information Engineering, Shenzhen University, Shenzhen, Guangdong, China.
| | - Guoxing Wang
- Department of Micro/Nano Electronics, School of Electrical, Information, and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China; Key Laboratory of Shanghai Education Commission for Intelligent Interaction and Cognitive Engineering, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
18
|
Ibtehaz N, Mahmud S, Chowdhury MEH, Khandakar A, Salman Khan M, Ayari MA, Tahir AM, Rahman MS. PPG2ABP: Translating Photoplethysmogram (PPG) Signals to Arterial Blood Pressure (ABP) Waveforms. Bioengineering (Basel) 2022; 9:692. [PMID: 36421093 PMCID: PMC9687508 DOI: 10.3390/bioengineering9110692] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/08/2022] [Accepted: 11/11/2022] [Indexed: 08/13/2023] Open
Abstract
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.
Collapse
Affiliation(s)
- Nabil Ibtehaz
- Department of Computer Science, Purdue University, West Lafayette, IN 47907, USA
| | - Sakib Mahmud
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | | | - Amith Khandakar
- Department of Electrical Engineering, Qatar University, Doha 2713, Qatar
| | | | - Mohamed Arselene Ayari
- Department of Civil and Architectural Engineering, Qatar University, Doha 2713, Qatar
- Technology Innovation and Engineering Education Unit (TIEE), Qatar University, Doha 2713, Qatar
| | - Anas M. Tahir
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada
| | - M. Sohel Rahman
- Department of CSE, BUET, ECE Building, West Palashi, Dhaka 1205, Bangladesh
| |
Collapse
|
19
|
Zabihi S, Rahimian E, Marefat F, Asif A, Mohseni P, Mohammadi A. BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
20
|
Ismail SNA, Nayan NA, Jaafar R, May Z. Recent Advances in Non-Invasive Blood Pressure Monitoring and Prediction Using a Machine Learning Approach. SENSORS (BASEL, SWITZERLAND) 2022; 22:6195. [PMID: 36015956 PMCID: PMC9412312 DOI: 10.3390/s22166195] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2022] [Revised: 07/25/2022] [Accepted: 08/04/2022] [Indexed: 06/15/2023]
Abstract
Blood pressure (BP) monitoring can be performed either invasively via arterial catheterization or non-invasively through a cuff sphygmomanometer. However, for conscious individuals, traditional cuff-based BP monitoring devices are often uncomfortable, intermittent, and impractical for frequent measurements. Continuous and non-invasive BP (NIBP) monitoring is currently gaining attention in the human health monitoring area due to its promising potentials in assessing the health status of an individual, enabled by machine learning (ML), for various purposes such as early prediction of disease and intervention treatment. This review presents the development of a non-invasive BP measuring tool called sphygmomanometer in brief, summarizes state-of-the-art NIBP sensors, and identifies extended works on continuous NIBP monitoring using commercial devices. Moreover, the NIBP predictive techniques including pulse arrival time, pulse transit time, pulse wave velocity, and ML are elaborated on the basis of bio-signals acquisition from these sensors. Additionally, the different BP values (systolic BP, diastolic BP, mean arterial pressure) of the various ML models adopted in several reported studies are compared in terms of the international validation standards developed by the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) for clinically-approved BP monitors. Finally, several challenges and possible solutions for the implementation and realization of continuous NIBP technology are addressed.
Collapse
Affiliation(s)
- Siti Nor Ashikin Ismail
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Nazrul Anuar Nayan
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
- Institute Islam Hadhari, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Rosmina Jaafar
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
| | - Zazilah May
- Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, UKM Bangi 43600, Selangor, Malaysia
- Electrical and Electronic Engineering Department, Universiti Teknologi Petronas, Seri Iskandar 32610, Perak, Malaysia
| |
Collapse
|
21
|
Athaya T, Choi S. Real-Time Cuffless Continuous Blood Pressure Estimation Using 1D Squeeze U-Net Model: A Progress toward mHealth. BIOSENSORS 2022; 12:bios12080655. [PMID: 36005051 PMCID: PMC9405546 DOI: 10.3390/bios12080655] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/10/2022] [Accepted: 08/16/2022] [Indexed: 12/01/2022]
Abstract
Measuring continuous blood pressure (BP) in real time by using a mobile health (mHealth) application would open a new door in the advancement of the healthcare system. This study aimed to propose a real-time method and system for measuring BP without using a cuff from a digital artery. An energy-efficient real-time smartphone-application-friendly one-dimensional (1D) Squeeze U-net model is proposed to estimate systolic and diastolic BP values, using only raw photoplethysmogram (PPG) signal. The proposed real-time cuffless BP prediction method was assessed for accuracy, reliability, and potential usefulness in the hypertensive assessment of 100 individuals in two publicly available datasets: Multiparameter Intelligent Monitoring in Intensive Care (MIMIC-I) and Medical Information Mart for Intensive Care (MIMIC-III) waveform database. The proposed model was used to build an android application to measure BP at home. This proposed deep-learning model performs best in terms of systolic BP, diastolic BP, and mean arterial pressure, with a mean absolute error of 4.42, 2.25, and 2.56 mmHg and standard deviation of 4.78, 2.98, and 3.21 mmHg, respectively. The results meet the grade A performance requirements of the British Hypertension Society and satisfy the AAMI error range. The result suggests that only using a short-time PPG signal is sufficient to obtain accurate BP measurements in real time. It is a novel approach for real-time cuffless BP estimation by implementing an mHealth application and can measure BP at home and assess hypertension.
Collapse
Affiliation(s)
- Tasbiraha Athaya
- Department of Computer Science, University of Central Florida, Orlando, FL 32816, USA
| | - Sunwoong Choi
- School of Electrical Engineering, Kookmin University, Seoul 02707, Korea
- Correspondence:
| |
Collapse
|
22
|
A computationally efficient CNN-LSTM neural network for estimation of blood pressure from features of electrocardiogram and photoplethysmogram waveforms. Knowl Based Syst 2022. [DOI: 10.1016/j.knosys.2022.109151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
23
|
Cuffless blood pressure measuring devices: review and statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability. J Hypertens 2022; 40:1449-1460. [PMID: 35708294 DOI: 10.1097/hjh.0000000000003224] [Citation(s) in RCA: 78] [Impact Index Per Article: 39.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Many cuffless blood pressure (BP) measuring devices are currently on the market claiming that they provide accurate BP measurements. These technologies have considerable potential to improve the awareness, treatment, and management of hypertension. However, recent guidelines by the European Society of Hypertension do not recommend cuffless devices for the diagnosis and management of hypertension. OBJECTIVE This statement by the European Society of Hypertension Working Group on BP Monitoring and Cardiovascular Variability presents the types of cuffless BP technologies, issues in their validation, and recommendations for clinical practice. STATEMENTS Cuffless BP monitors constitute a wide and heterogeneous group of novel technologies and devices with different intended uses. Cuffless BP devices have specific accuracy issues, which render the established validation protocols for cuff BP devices inadequate for their validation. In 2014, the Institute of Electrical and Electronics Engineers published a standard for the validation of cuffless BP devices, and the International Organization for Standardization is currently developing another standard. The validation of cuffless devices should address issues related to the need of individual cuff calibration, the stability of measurements post calibration, the ability to track BP changes, and the implementation of machine learning technology. Clinical field investigations may also be considered and issues regarding the clinical implementation of cuffless BP readings should be investigated. CONCLUSION Cuffless BP devices have considerable potential for changing the diagnosis and management of hypertension. However, fundamental questions regarding their accuracy, performance, and implementation need to be carefully addressed before they can be recommended for clinical use.
Collapse
|
24
|
Landry C, Peterson SD, Arami A. A fusion approach to improve accuracy and estimate uncertainty in cuffless blood pressure monitoring. Sci Rep 2022; 12:7948. [PMID: 35562410 PMCID: PMC9106676 DOI: 10.1038/s41598-022-12087-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 04/29/2022] [Indexed: 11/18/2022] Open
Abstract
A substantial barrier to the clinical adoption of cuffless blood pressure (BP) monitoring techniques is the lack of unified error standards and methods of estimating measurement uncertainty. This study proposes a fusion approach to improve accuracy and estimate prediction interval (PI) as a proxy for uncertainty for cuffless blood BP monitoring. BP was estimated during activities of daily living using three model architectures: nonlinear autoregressive models with exogenous inputs, feedforward neural network models, and pulse arrival time models. Multiple one-class support vector machine (OCSVM) models were trained to cluster data in terms of the percentage of outliers. New BP estimates were then assigned to a cluster using the OCSVMs hyperplanes, and the PIs were estimated using the BP error standard deviation associated with different clusters. The OCSVM was used to estimate the PI for the three BP models. The three BP estimations from the models were fused using the covariance intersection fusion algorithm, which improved BP and PI estimates in comparison with individual model precision by up to 24%. The employed model fusion shows promise in estimating BP and PI for potential clinical uses. The PI indicates that about 71%, 64%, and 29% of the data collected from sitting, standing, and walking can result in high-quality BP estimates. Our PI estimator offers an effective uncertainty metric to quantify the quality of BP estimates and can minimize the risk of false diagnosis.
Collapse
Affiliation(s)
- Cederick Landry
- Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON, Canada
| | - Sean D Peterson
- Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON, Canada
| | - Arash Arami
- Mechanical and Mechatronics Engineering Department, University of Waterloo, Waterloo, ON, Canada.
- Toronto Rehabilitation Institute (KITE), University Health Network, Toronto, ON, Canada.
| |
Collapse
|
25
|
Jiang H, Zou L, Huang D, Feng Q. Continuous Blood Pressure Estimation Based on Multi-Scale Feature Extraction by the Neural Network With Multi-Task Learning. Front Neurosci 2022; 16:883693. [PMID: 35600611 PMCID: PMC9120547 DOI: 10.3389/fnins.2022.883693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 04/15/2022] [Indexed: 11/15/2022] Open
Abstract
In this article, a novel method for continuous blood pressure (BP) estimation based on multi-scale feature extraction by the neural network with multi-task learning (MST-net) has been proposed and evaluated. First, we preprocess the target (Electrocardiograph; Photoplethysmography) and label signals (arterial blood pressure), especially using peak-to-peak time limits of signals to eliminate the interference of the false peak. Then, we design a MST-net to extract multi-scale features related to BP, fully excavate and learn the relationship between multi-scale features and BP, and then estimate three BP values simultaneously. Finally, the performance of the developed neural network is verified by using a public multi-parameter intelligent monitoring waveform database. The results show that the mean absolute error ± standard deviation for systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) with the proposed method against reference are 4.04 ± 5.81, 2.29 ± 3.55, and 2.46 ± 3.58 mmHg, respectively; the correlation coefficients of SBP, DBP, and MAP are 0.96, 0.92, and 0.94, respectively, which meet the Association for the Advancement of Medical Instrumentation standard and reach A level of the British Hypertension Society standard. This study provides insights into the improvement of accuracy and efficiency of a continuous BP estimation method with a simple structure and without calibration. The proposed algorithm for BP estimation could potentially enable continuous BP monitoring by mobile health devices.
Collapse
Affiliation(s)
- Hengbing Jiang
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Institute of Biological and Medical Engineering, Guangdong Academy of Sciences & National Engineering Research Center for Healthcare Devices, Guangzhou, China
- Guangdong Engineering Technology Research Center for Diagnosis and Rehabilitation of Dementia, Guangzhou, China
| | - Lili Zou
- Institute of Biological and Medical Engineering, Guangdong Academy of Sciences & National Engineering Research Center for Healthcare Devices, Guangzhou, China
- Guangdong Engineering Technology Research Center for Diagnosis and Rehabilitation of Dementia, Guangzhou, China
- *Correspondence: Lili Zou,
| | - Dequn Huang
- Institute of Biological and Medical Engineering, Guangdong Academy of Sciences & National Engineering Research Center for Healthcare Devices, Guangzhou, China
- Guangdong Engineering Technology Research Center for Diagnosis and Rehabilitation of Dementia, Guangzhou, China
| | - Qianjin Feng
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
- Qianjin Feng,
| |
Collapse
|
26
|
Kim DK, Kim YT, Kim H, Kim DJ. DeepCNAP: A Deep Learning Approach for Continuous Noninvasive Arterial Blood Pressure Monitoring Using Photoplethysmography. IEEE J Biomed Health Inform 2022; 26:3697-3707. [PMID: 35511844 DOI: 10.1109/jbhi.2022.3172514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Arterial blood pressure (ABP) monitoring may permit the early diagnosis and management of cardiovascular disease (CVD); however, existing methods for measuring ABP outside the clinic use inconvenient cuff sphygmomanometry, or do not estimate continuous ABP waveforms. This study proposes a novel deep learning model DeepCNAP for estimating continuous BP waveform from a noninvasively measured photoplethysmography (PPG) signal in real time. DeepCNAP was designed through the combination of deep convolutional networks and self-attention. The proposed method was constructed via 10-fold cross-validation based on the MIMIC database (the number of subjects = 942, recording time = 374.43 hours). The performance of DeepCNAP was evaluated from two perspectives: estimating ABP from PPG and classifying hemodynamically unstable events (i.e., hypertension, prehypertension, hypotension, and the normal state). The mean absolute errors of the BP estimates were 3.40 4.36 mmHg for systolic BP, 1.75 2.25 mmHg for diastolic BP, and 3.23 2.21 mmHg for the BP waveform, indicating that DeepCNAP satisfies the standards of both the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). From the estimated BP, hypertension, prehypertension, hypotension, and the normal state were classified with 99.44, 97.58, 92.23, and 94.64% accuracy, respectively. DeepCNAP enables feasible real-time estimation of invasively measured ABP from noninvasive PPG. With its noninvasive nature, high accuracy, and clinical relevance, the proposed model could be valuable in general wards at hospitals and for wearable devices in daily life.
Collapse
|
27
|
Ni Z, Sun F, Li Y. Heart Rate Variability-Based Subjective Physical Fatigue Assessment. SENSORS 2022; 22:s22093199. [PMID: 35590889 PMCID: PMC9100264 DOI: 10.3390/s22093199] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 04/19/2022] [Accepted: 04/20/2022] [Indexed: 02/04/2023]
Abstract
Accurate assessment of physical fatigue is crucial to preventing physical injury caused by excessive exercise, overtraining during daily exercise and professional sports training. However, as a subjective feeling of an individual, physical fatigue is difficult for others to objectively evaluate. Heart rate variability (HRV), which is derived from electrocardiograms (ECG) and controlled by the autonomic nervous system, has been demonstrated to be a promising indicator for physical fatigue estimation. In this paper, we propose a novel method for the automatic and objective classification of physical fatigue based on HRV. First, a total of 24 HRV features were calculated. Then, a feature selection method was proposed to remove useless features that have a low correlation with physical fatigue and redundant features that have a high correlation with the selected features. After feature selection, the best 11 features were selected and were finally used for physical fatigue classifying. Four machine learning algorithms were trained to classify fatigue using the selected features. The experimental results indicate that the model trained using the selected 11 features could classify physical fatigue with high accuracy. More importantly, these selected features could provide important information regarding the identification of physical fatigue.
Collapse
Affiliation(s)
- Zhiqiang Ni
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Fangmin Sun
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
| | - Ye Li
- Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China; (Z.N.); (F.S.)
- Correspondence:
| |
Collapse
|
28
|
Yao P, Xue N, Yin S, You C, Guo Y, Shi Y, Liu T, Yao L, Zhou J, Sun J, Dong C, Liu C, Zhao M. Multi-Dimensional Feature Combination Method for Continuous Blood Pressure Measurement Based on Wrist PPG Sensor. IEEE J Biomed Health Inform 2022; 26:3708-3719. [PMID: 35417358 DOI: 10.1109/jbhi.2022.3167059] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The cuffless blood pressure monitoring method based on photoplethysmogram (PPG) makes it possible for long-term blood pressure monitoring to prevent and treat cardiovascular and cerebrovascular events. However, the traditional feature extraction is based on two separate sensors, which is inconvenient. In a single sensor measurement, the prediction model based on a single feature group usually does not perform well. This paper presents an artificial neural network (ANN) model for predicting blood pressure based on feature combinations. The robustness of the model is improved from three aspects. Firstly, an adaptive peak extraction algorithm is used to improve the accuracy of peaks and troughs detection. Secondly, multi-dimensional features are extracted and fused, including three groups of PPG-based features and one group of demographics-based features. Finally, a two-layer feedforward artificial neural networks algorithm is used for regression. Thirty-three subjects distributed in three blood pressure groups were recruited. The proposed method passes the European Society of Hypertension International Protocol revision 2010 (ESP-IP2). Experimental results show that the proposed method exhibits good accuracy for a diverse population with an estimation error of 0.03 4.27 mmHg for SBP and 0.01 3.38 for DBP. Moreover, the model can track blood pressure in a long-term range, which demonstrates the robustness of the algorithm. This work will contribute to the long-term wellness management and rehabilitation process, enabling timely detection and improvement of the user's physical health.
Collapse
|
29
|
Rossi M, Alessandrelli G, Dombrovschi A, Bovio D, Salito C, Mainardi L, Cerveri P. Identification of Characteristic Points in Multivariate Physiological Signals by Sensor Fusion and Multi-Task Deep Networks. SENSORS 2022; 22:s22072684. [PMID: 35408297 PMCID: PMC9003131 DOI: 10.3390/s22072684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 03/28/2022] [Accepted: 03/28/2022] [Indexed: 11/28/2022]
Abstract
Identification of characteristic points in physiological signals, such as the peak of the R wave in the electrocardiogram and the peak of the systolic wave of the photopletismogram, is a fundamental step for the quantification of clinical parameters, such as the pulse transit time. In this work, we presented a novel neural architecture, called eMTUnet, to automate point identification in multivariate signals acquired with a chest-worn device. The eMTUnet consists of a single deep network capable of performing three tasks simultaneously: (i) localization in time of characteristic points (labeling task), (ii) evaluation of the quality of signals (classification task); (iii) estimation of the reliability of classification (reliability task). Preliminary results in overnight monitoring showcased the ability to detect characteristic points in the four signals with a recall index of about 1.00, 0.90, 0.90, and 0.80, respectively. The accuracy of the signal quality classification was about 0.90, on average over four different classes. The average confidence of the correctly classified signals, against the misclassifications, was 0.93 vs. 0.52, proving the worthiness of the confidence index, which may better qualify the point identification. From the achieved outcomes, we point out that high-quality segmentation and classification are both ensured, which brings the use of a multi-modal framework, composed of wearable sensors and artificial intelligence, incrementally closer to clinical translation.
Collapse
Affiliation(s)
- Matteo Rossi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
- Correspondence: (M.R.); (P.C.)
| | - Giulia Alessandrelli
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Andra Dombrovschi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Dario Bovio
- Biocubica SRL, 20154 Milan, Italy; (D.B.); (C.S.)
| | | | - Luca Mainardi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
| | - Pietro Cerveri
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy; (G.A.); (A.D.); (L.M.)
- Correspondence: (M.R.); (P.C.)
| |
Collapse
|
30
|
Miao F, Zhou B, Liu Z, Wen B, Li Y, Tang M. Using noninvasive adjusted pulse transit time for tracking beat-to-beat systolic blood pressure during ventricular arrhythmia. Hypertens Res 2022; 45:424-435. [PMID: 34931020 DOI: 10.1038/s41440-021-00795-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Revised: 09/26/2021] [Accepted: 10/07/2021] [Indexed: 12/12/2022]
Abstract
Tracking beat-to-beat blood pressure noninvasively during ventricular arrhythmia (VA) is of great importance but rarely reported. The goal of our study was to investigate the potential utility of the adjusted pulse transit time (APTT) to track beat-to-beat femoral systolic blood pressure (SBP) during VA. Patients who underwent radiofrequency ablation for arrhythmias at Fuwai Hospital were enrolled. Electrocardiograms (ECGs), finger photoplethysmograms, and femoral arterial blood pressure were recorded simultaneously during VA. The APTT was calculated as the ratio between the square of the conventional pulse transit time (cPTT) and the RR interval of the ECG waveform. Forty-five patients were enrolled in our study, and 22,849 beats were collected during their VA. The inverse of the APTT showed a good correlation with femoral SBP during VA (r = 0.70 ± 0.18). The APTT-derived SBP demonstrated acceptable accuracy in terms of the mean difference ± standard deviation (-0.01 ± 10.54 mmHg) from the invasive femoral SBP. The area under the receiver operating characteristic (ROC) curve for the ability of the APTT to detect ≥30% decreases in femoral SBP was 0.903 (95% confidential interval, 0.895-0.911). In addition, the APTT performed better than the cPTT and RR interval in the above analysis (all P < 0.05). Therefore, the APTT has acceptable accuracy in tracking beat-to-beat femoral SBP and could detect substantially decreased femoral SBP. These findings indicate that the APTT may be a promising noninvasive surrogate for invasive femoral SBP during VA. A multiparameter model combining APTT and other parameters is needed to further improve the accuracy.
Collapse
Affiliation(s)
- Fen Miao
- Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Bin Zhou
- Department of Cardiology, Laboratory of Heart Center, Zhujiang Hospital, Southern Medical University, Guangzhou, China.,Fuwai Hospital, National Center for Cardiovascular Disease, State Key Lab of Cardiovascular Disease, National Clinical Research Center of Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Zengding Liu
- Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Bo Wen
- Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Ye Li
- Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.,Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Min Tang
- Fuwai Hospital, National Center for Cardiovascular Disease, State Key Lab of Cardiovascular Disease, National Clinical Research Center of Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
| |
Collapse
|
31
|
Wang TW, Syu JY, Chu HW, Sung YL, Chou L, Escott E, Escott O, Lin TT, Lin SF. Intelligent Bio-Impedance System for Personalized Continuous Blood Pressure Measurement. BIOSENSORS 2022; 12:bios12030150. [PMID: 35323420 PMCID: PMC8946827 DOI: 10.3390/bios12030150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Revised: 02/25/2022] [Accepted: 02/26/2022] [Indexed: 11/26/2022]
Abstract
Continuous blood pressure (BP) measurement is crucial for long-term cardiovascular monitoring, especially for prompt hypertension detection. However, most of the continuous BP measurements rely on the pulse transit time (PTT) from multiple-channel physiological acquisition systems that impede wearable applications. Recently, wearable and smart health electronics have become significant for next-generation personalized healthcare progress. This study proposes an intelligent single-channel bio-impedance system for personalized BP monitoring. Compared to the PTT-based methods, the proposed sensing configuration greatly reduces the hardware complexity, which is beneficial for wearable applications. Most of all, the proposed system can extract the significant BP features hidden from the measured bio-impedance signals by an ultra-lightweight AI algorithm, implemented to further establish a tailored BP model for personalized healthcare. In the human trial, the proposed system demonstrates the BP accuracy in terms of the mean error (ME) and the mean absolute error (MAE) within 1.7 ± 3.4 mmHg and 2.7 ± 2.6 mmHg, respectively, which agrees with the criteria of the Association for the Advancement of Medical Instrumentation (AAMI). In conclusion, this work presents a proof-of-concept for an AI-based single-channel bio-impedance BP system. The new wearable smart system is expected to accelerate the artificial intelligence of things (AIoT) technology for personalized BP healthcare in the future.
Collapse
Affiliation(s)
- Ting-Wei Wang
- Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125, USA;
- Department of Electrical Engineering, California Institute of Technology, Pasadena, CA 91125, USA
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
| | - Jhen-Yang Syu
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
| | - Hsiao-Wei Chu
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
| | - Yen-Ling Sung
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
- Department of Cardiology, Smidt Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA 90048, USA
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu 300195, Taiwan
- Cardiovascular Center, National Taiwan University Hospital Hsinchu Branch, Hsinchu 300195, Taiwan
| | - Lin Chou
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
| | - Endian Escott
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA; (E.E.); (O.E.)
| | - Olivia Escott
- Department of Electrical Engineering and Computer Science, Florida Atlantic University, Boca Raton, FL 33431, USA; (E.E.); (O.E.)
| | - Ting-Tse Lin
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu 300195, Taiwan
- Cardiovascular Center, National Taiwan University Hospital Hsinchu Branch, Hsinchu 300195, Taiwan
- College of Medicine, National Taiwan University, Taipei 10617, Taiwan
- Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, Taipei 10025, Taiwan
- Correspondence: (T.-T.L.); (S.-F.L.)
| | - Shien-Fong Lin
- Institute of Biomedical Engineering, National Yang Ming Chiao Tung University, Hsinchu 30010, Taiwan; (J.-Y.S.); (H.-W.C.); (Y.-L.S.); (L.C.)
- Correspondence: (T.-T.L.); (S.-F.L.)
| |
Collapse
|
32
|
Cuffless Blood Pressure Measurement Using Linear and Nonlinear Optimized Feature Selection. Diagnostics (Basel) 2022; 12:diagnostics12020408. [PMID: 35204499 PMCID: PMC8870879 DOI: 10.3390/diagnostics12020408] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Revised: 01/30/2022] [Accepted: 01/30/2022] [Indexed: 02/04/2023] Open
Abstract
The cuffless blood pressure (BP) measurement allows for frequent measurement without discomfort to the patient compared to the cuff inflation measurement. With the availability of a large dataset containing physiological waveforms, now it is possible to use them through different learning algorithms to produce a relationship with changes in BP. In this paper, a novel cuffless noninvasive blood pressure measurement technique has been proposed using optimized features from electrocardiogram and photoplethysmography based on multivariate symmetric uncertainty (MSU). The technique is an improvement over other contemporary methods due to the inclusion of feature optimization depending on both linear and nonlinear relationships with the change of blood pressure. MSU has been used as a selection criterion with algorithms such as the fast correlation and ReliefF algorithms followed by the penalty-based regression technique to make sure the features have maximum relevance as well as minimum redundancy. The result from the technique was compared with the performance of similar techniques using the MIMIC-II dataset. After training and testing, the root mean square error (RMSE) comes as 5.28 mmHg for systolic BP and 5.98 mmHg for diastolic BP. In addition, in terms of mean absolute error, the result improved to 4.27 mmHg for SBP and 5.01 for DBP compared to recent cuffless BP measurement techniques which have used substantially large datasets and feature optimization. According to the British Hypertension Society Standard (BHS), our proposed technique achieved at least grade B in all cumulative criteria for cuffless BP measurement.
Collapse
|
33
|
Farki A, Baradaran Kazemzadeh R, Akhondzadeh Noughabi E. A Novel Clustering-Based Algorithm for Continuous and Noninvasive Cuff-Less Blood Pressure Estimation. JOURNAL OF HEALTHCARE ENGINEERING 2022; 2022:3549238. [PMID: 35075386 PMCID: PMC8783699 DOI: 10.1155/2022/3549238] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Revised: 12/18/2021] [Accepted: 12/24/2021] [Indexed: 11/29/2022]
Abstract
Extensive research has been performed on continuous and noninvasive cuff-less blood pressure (BP) measurement using artificial intelligence algorithms. This approach involves extracting certain features from physiological signals, such as ECG, PPG, ICG, and BCG, as independent variables and extracting features from arterial blood pressure (ABP) signals as dependent variables and then using machine-learning algorithms to develop a blood pressure estimation model based on these data. The greatest challenge of this field is the insufficient accuracy of estimation models. This paper proposes a novel blood pressure estimation method with a clustering step for accuracy improvement. The proposed method involves extracting pulse transit time (PTT), PPG intensity ratio (PIR), and heart rate (HR) features from electrocardiogram (ECG) and photoplethysmogram (PPG) signals as the inputs of clustering and regression, extracting systolic blood pressure (SBP) and diastolic blood pressure (DBP) features from ABP signals as dependent variables, and finally developing regression models by applying gradient boosting regression (GBR), random forest regression (RFR), and multilayer perceptron regression (MLP) on each cluster. The method was implemented using the MIMIC-II data set with the silhouette criterion used to determine the optimal number of clusters. The results showed that because of the inconsistency, high dispersion, and multitrend behavior of the extracted features vectors, the accuracy can be significantly improved by running a clustering algorithm and then developing a regression model on each cluster and finally weighted averaging of the results based on the error of each cluster. When implemented with 5 clusters and GBR, this approach yielded an MAE of 2.56 for SBP estimates and 2.23 for DBP estimates, which were significantly better than the best results without clustering (DBP: 6.27, SBP: 6.36).
Collapse
Affiliation(s)
- Ali Farki
- Department of Information Technology Engineering Industrial and Systems Engineering Faculty, Tarbiat Modares University, Tehran, Iran
| | - Reza Baradaran Kazemzadeh
- Department of Information Technology Engineering Industrial and Systems Engineering Faculty, Tarbiat Modares University, Tehran, Iran
| | - Elham Akhondzadeh Noughabi
- Department of Information Technology Engineering Industrial and Systems Engineering Faculty, Tarbiat Modares University, Tehran, Iran
| |
Collapse
|
34
|
Ibrahim B, Jafari R. Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder. Sci Rep 2022; 12:319. [PMID: 35013376 PMCID: PMC8748973 DOI: 10.1038/s41598-021-03612-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 12/06/2021] [Indexed: 12/12/2022] Open
Abstract
Continuous monitoring of blood pressure (BP) is essential for the prediction and the prevention of cardiovascular diseases. Cuffless BP methods based on non-invasive sensors integrated into wearable devices can translate blood pulsatile activity into continuous BP data. However, local blood pulsatile sensors from wearable devices suffer from inaccurate pulsatile activity measurement based on superficial capillaries, large form-factor devices and BP variation with sensor location which degrade the accuracy of BP estimation and the device wearability. This study presents a cuffless BP monitoring method based on a novel bio-impedance (Bio-Z) sensor array built in a flexible wristband with small-form factor that provides a robust blood pulsatile sensing and BP estimation without calibration methods for the sensing location. We use a convolutional neural network (CNN) autoencoder that reconstructs an accurate estimate of the arterial pulse signal independent of sensing location from a group of six Bio-Z sensors within the sensor array. We rely on an Adaptive Boosting regression model which maps the features of the estimated arterial pulse signal to systolic and diastolic BP readings. BP was accurately estimated with average error and correlation coefficient of 0.5 ± 5.0 mmHg and 0.80 for diastolic BP, and 0.2 ± 6.5 mmHg and 0.79 for systolic BP, respectively.
Collapse
Affiliation(s)
- Bassem Ibrahim
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA.
| | - Roozbeh Jafari
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA. .,Department of Biomedical Engineering, Texas A&M University, College Station, TX, USA. .,Department of Computer Science and Engineering, Texas A&M University, College Station, TX, USA.
| |
Collapse
|
35
|
Khan Mamun MMR. Cuff-less blood pressure measurement based on hybrid feature selection algorithm and multi-penalty regularized regression technique. Biomed Phys Eng Express 2021; 7. [PMID: 34633299 DOI: 10.1088/2057-1976/ac2ea8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 10/11/2021] [Indexed: 11/11/2022]
Abstract
One of the prominent reasons behind the deterioration of cardiovascular conditions is hypertension. Due to lack of specific symptoms, sometimes existing hypertension goes unnoticed until significant damage happens to the heart or any other body organ. Monitoring of BP at a higher frequency is necessary so that we can take early preventive measures to control and keep it within the normal range. The cuff-based method of measuring BP is inconvenient for frequent daily measurements. The cuffless BP measurement method proposed in this paper uses features extracted from the electrocardiogram (ECG) and photoplethysmography (PPG). ECG and PPG both have distinct characteristics, which change with the change of blood pressure levels. Feature extraction and hybrid feature selection algorithms are followed by a generalized penalty-based regression technique led to a new BP measurement process that uses the minimum number of features. The performance of the proposed technique to measure blood pressure was compared to an approach using an ordinary linear regression method with no feature selection and to other contemporary techniques. MIMIC-II database was used to train and test our proposed method. The root mean square error (RMSE) for systolic blood pressure (SBP) improved from 11.2 mmHg to 5.6 mmHg when the proposed technique was implemented and for diastolic blood pressure (DBP) improved from 12.7 mmHg to 6.69 mmHg. The mean absolute error (MAE) was found to be 4.91 mmHg for SBP and 5.77 mmHg for DBP, which have shown improvement over other existing cuffless techniques where the substantial number of patients, as well as feature selection algorithm, were implemented. In addition, according to the British Hypertension Society standard (BHS) standard for cuff-based BP measurement, the criteria for acceptable measurement are to achieve at least grade B; our proposed method also satisfies this criterion.
Collapse
|
36
|
Mukkamala R, Yavarimanesh M, Natarajan K, Hahn JO, Kyriakoulis KG, Avolio AP, Stergiou GS. Evaluation of the Accuracy of Cuffless Blood Pressure Measurement Devices: Challenges and Proposals. Hypertension 2021; 78:1161-1167. [PMID: 34510915 DOI: 10.1161/hypertensionaha.121.17747] [Citation(s) in RCA: 80] [Impact Index Per Article: 26.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Several novel cuffless wearable devices and smartphone applications claiming that they can measure blood pressure (BP) are appearing on the market. These technologies are very attractive and promising, with increasing interest among health care professionals for their potential use. Moreover, they are becoming popular among patients with hypertension and healthy people. However, at the present time, there are serious issues about BP measurement accuracy of cuffless devices and the 2021 European Society of Hypertension Guidelines on BP measurement do not recommend them for clinical use. Cuffless devices have special validation issues, which have been recently recognized. It is important to note that the 2018 Universal Standard for the validation of automated BP measurement devices developed by the American Association for the Advancement of Medical Instrumentation, the European Society of Hypertension, and the International Organization for Standardization is inappropriate for the validation of cuffless devices. Unfortunately, there is an increasing number of publications presenting data on the accuracy of novel cuffless BP measurement devices, with inadequate methodology and potentially misleading conclusions. The objective of this review is to facilitate understanding of the capabilities and limitations of emerging cuffless BP measurement devices. First, the potential and the types of these devices are described. Then, the unique challenges in evaluating the BP measurement accuracy of cuffless devices are explained. Studies from the literature and computer simulations are employed to illustrate these challenges. Finally, proposals are given on how to evaluate cuffless devices including presenting and interpreting relevant study results.
Collapse
Affiliation(s)
- Ramakrishna Mukkamala
- Departments of Bioengineering, Anesthesiology and Perioperative Medicine, University of Pittsburgh, PA (R.M.)
| | - Mohammad Yavarimanesh
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing (M.Y., K.N.)
| | - Keerthana Natarajan
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing (M.Y., K.N.)
| | - Jin-Oh Hahn
- Department of Mechanical Engineering, University of Maryland, College Park (J.-O.H.)
| | - Konstantinos G Kyriakoulis
- Hypertension Center STRIDE-7, School of Medicine, Third Department of Medicine, Sotiria Hospital, National and Kapodistrian University of Athens, Greece (K.G.K., G.S.S.)
| | - Alberto P Avolio
- Macquarie School of Medicine, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia (A.P.A.)
| | - George S Stergiou
- Hypertension Center STRIDE-7, School of Medicine, Third Department of Medicine, Sotiria Hospital, National and Kapodistrian University of Athens, Greece (K.G.K., G.S.S.)
| |
Collapse
|
37
|
Muhammad G, Shamim Hossain M. COVID-19 and Non-COVID-19 Classification using Multi-layers Fusion From Lung Ultrasound Images. AN INTERNATIONAL JOURNAL ON INFORMATION FUSION 2021; 72:80-88. [PMID: 33649704 PMCID: PMC7904462 DOI: 10.1016/j.inffus.2021.02.013] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 11/26/2020] [Accepted: 02/21/2021] [Indexed: 05/18/2023]
Abstract
COVID-19 or related viral pandemics should be detected and managed without hesitation, since the virus spreads very rapidly. Often with insufficient human and electronic resources, patients need to be checked from stable patients using vital signs, radiographic photographs, or ultrasound images. Vital signs do not often offer the right outcome, and radiographic photos have a variety of other problems. Lung ultrasound (LUS) images can provide good screening without a lot of complications. This paper suggests a model of a convolutionary neural network (CNN) that has fewer learning parameters but can achieve strong accuracy. The model has five main blocks or layers of convolution connectors. A multi-layer fusion functionality of each block is proposed to improve the efficiency of the COVID-19 screening method utilizing the proposed model. Experiments are conducted using freely accessible LUS photographs and video datasets. The proposed fusion method has 92.5% precision, 91.8% accuracy, and 93.2% retrieval using the data collection. These efficiency metric levels are considerably higher than those used in any of the state-of-the-art CNN versions.
Collapse
Affiliation(s)
- Ghulam Muhammad
- Chair of Pervasive and Mobile Computing, King Saud University, Riyadh 11543, Saudi Arabia
- Department of Computer Engineering, College of Computer and Information Sciences, King Saud University, Riyadh 11543, Saudi Arabia
| | - M Shamim Hossain
- Chair of Pervasive and Mobile Computing, King Saud University, Riyadh 11543, Saudi Arabia
- Department of Software Engineering, College of Computer and Information Sciences, King Saud University, Riyadh 11543, Saudi Arabia
| |
Collapse
|
38
|
Baker S, Xiang W, Atkinson I. A hybrid neural network for continuous and non-invasive estimation of blood pressure from raw electrocardiogram and photoplethysmogram waveforms. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 207:106191. [PMID: 34077866 DOI: 10.1016/j.cmpb.2021.106191] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 05/12/2021] [Indexed: 05/22/2023]
Abstract
BACKGROUND AND OBJECTIVES Continuous and non-invasive blood pressure monitoring would revolutionize healthcare. Currently, blood pressure (BP) can only be accurately monitored using obtrusive cuff-based devices or invasive intra-arterial monitoring. In this work, we propose a novel hybrid neural network for the accurate estimation of blood pressure (BP) using only non-invasive electrocardiogram (ECG) and photoplethysmogram (PPG) waveforms as inputs. METHODS This work proposes a hybrid neural network combines the feature detection abilities of temporal convolutional layers with the strong performance on sequential data offered by long short-term memory layers. Raw electrocardiogram and photoplethysmogram waveforms are concatenated and used as network inputs. The network was developed using the TensorFlow framework. Our scheme is analysed and compared to the literature in terms of well known standards set by the British Hypertension Society (BHS) and the Association for the Advancement of Medical Instrumentation (AAMI). RESULTS Our scheme achieves extremely low mean absolute errors (MAEs) of 4.41 mmHg for SBP, 2.91 mmHg for DBP, and 2.77 mmHg for MAP. A strong level of agreement between our scheme and the gold-standard intra-arterial monitoring is shown through Bland Altman and regression plots. Additionally, the standard for BP devices established by AAMI is met by our scheme. We also achieve a grade of 'A' based on the criteria outlined by the BHS protocol for BP devices. CONCLUSIONS Our CNN-LSTM network outperforms current state-of-the-art schemes for non-invasive BP measurement from PPG and ECG waveforms. These results provide an effective machine learning approach that could readily be implemented into non-invasive wearable devices for use in continuous clinical and at-home monitoring.
Collapse
Affiliation(s)
- Stephanie Baker
- College of Science & Engineering, James Cook University, Cairns, Queensland, Australia 4878, Australia.
| | - Wei Xiang
- School of Engineering and Mathematical Sciences, La Trobe University, Melbourne, Victoria, Australia 3086, Australia.
| | - Ian Atkinson
- eResearch Centre, James Cook University, Townsville, Queensland, Australia 4811, Australia.
| |
Collapse
|
39
|
Landry C, Hedge ET, Hughson RL, Peterson SD, Arami A. Accurate Blood Pressure Estimation During Activities of Daily Living: A Wearable Cuffless Solution. IEEE J Biomed Health Inform 2021; 25:2510-2520. [PMID: 33497346 DOI: 10.1109/jbhi.2021.3054597] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The objective is to develop a cuffless method that accurately estimates blood pressure (BP) during activities of daily living. User-specific nonlinear autoregressive models with exogenous inputs (NARX) are implemented using artificial neural networks to estimate the BP waveforms from electrocardiography and photoplethysmography signals. To broaden the range of BP in the training data, subjects followed a short procedure consisting of sitting, standing, walking, Valsalva maneuvers, and static handgrip exercises. The procedure was performed before and after a six-hour testing phase wherein five participants went about their normal daily living activities. Data were further collected at a four-month time point for two participants and again at six months for one of the two. The performance of three different NARX models was compared with three pulse arrival time (PAT) models. The NARX models demonstrate superior accuracy and correlation with "ground truth" systolic and diastolic BP measures compared to the PAT models and a clear advantage in estimating the large range of BP. Preliminary results show that the NARX models can accurately estimate BP even months apart from the training. Preliminary testing suggests that it is robust against variabilities due to sensor placement. This establishes a method for cuffless BP estimation during activities of daily living that can be used for continuous monitoring and acute hypotension and hypertension detection.
Collapse
|
40
|
Baker S, Xiang W, Atkinson I. Hybridized neural networks for non-invasive and continuous mortality risk assessment in neonates. Comput Biol Med 2021; 134:104521. [PMID: 34111664 DOI: 10.1016/j.compbiomed.2021.104521] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 05/06/2021] [Accepted: 05/25/2021] [Indexed: 11/19/2022]
Abstract
Premature birth is the primary risk factor in neonatal deaths, with the majority of extremely premature babies cared for in neonatal intensive care units (NICUs). Mortality risk prediction in this setting can greatly improve patient outcomes and resource utilization. However, existing schemes often require laborious medical testing and calculation, and are typically only calculated once at admission. In this work, we propose a shallow hybrid neural network for the prediction of mortality risk in 3-day, 7-day, and 14-day risk windows using only birthweight, gestational age, sex, and heart rate (HR) and respiratory rate (RR) information from a 12-h window. As such, this scheme is capable of continuously updating mortality risk assessment, enabling analysis of health trends and responses to treatment. The highest performing scheme was the network that considered mortality risk within 3 days, with this scheme outperforming state-of-the-art works in the literature and achieving an area under the receiver-operator curve (AUROC) of 0.9336 with standard deviation of 0.0337 across 5 folds of cross-validation. As such, we conclude that our proposed scheme could readily be used for continuously-updating mortality risk prediction in NICU environments.
Collapse
Affiliation(s)
- Stephanie Baker
- College of Science & Engineering, James Cook University, Cairns, Queensland, 4878, Australia.
| | - Wei Xiang
- School of Engineering and Mathematical Sciences, La Trobe University, Melbourne, Victoria, 3086, Australia
| | - Ian Atkinson
- eResearch Centre, James Cook University, Townsville, Queensland, 4811, Australia
| |
Collapse
|
41
|
Fan X, Wang H, Zhao Y, Li Y, Tsui KL. An Adaptive Weight Learning-Based Multitask Deep Network for Continuous Blood Pressure Estimation Using Electrocardiogram Signals. SENSORS 2021; 21:s21051595. [PMID: 33668778 PMCID: PMC7956522 DOI: 10.3390/s21051595] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 01/27/2021] [Accepted: 02/07/2021] [Indexed: 11/16/2022]
Abstract
Estimating blood pressure via combination analysis with electrocardiogram and photoplethysmography signals has attracted growing interest in continuous monitoring patients’ health conditions. However, most wearable/portal monitoring devices generally acquire only one kind of physiological signals due to the consideration of energy cost, device weight and size, etc. In this study, a novel adaptive weight learning-based multitask deep learning framework based on single lead electrocardiogram signals is proposed for continuous blood pressure estimation. Specifically, the proposed method utilizes a 2-layer bidirectional long short-term memory network as the sharing layer, followed by three identical architectures of 2-layer fully connected networks for task-specific blood pressure estimation. To learn the importance of task-specific losses automatically, an adaptive weight learning scheme based on the trend of validation loss is proposed. Extensive experiment results on Physionet Multiparameter Intelligent Monitoring in Intensive Care (MIMIC) II waveform database demonstrate that the proposed method using electrocardiogram signals obtains estimating performance of 0.12±10.83 mmHg, 0.13±5.90 mmHg, and 0.08±6.47 mmHg for systolic blood pressure, diastolic blood pressure, and mean arterial pressure, respectively. It can meet the requirements of the British Hypertension Society standard and US Association of Advancement of Medical Instrumentation standard with a considerable margin. Combined with a wearable/portal electrocardiogram device, the proposed model can be deployed to a healthcare system to provide a long-term continuous blood pressure monitoring service, which would help to reduce the incidence of malignant complications to hypertension.
Collapse
Affiliation(s)
- Xiaomao Fan
- School of Computer Science, South China Normal University, Guangzhou 510631, China;
| | - Hailiang Wang
- School of Design, Hong Kong Polytechnic University, Hong Kong, China;
| | - Yang Zhao
- School of Data Science, City University of Hong Kong, Hong Kong, China;
- Correspondence: or
| | - Ye Li
- Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China;
| | - Kwok Leung Tsui
- School of Data Science, City University of Hong Kong, Hong Kong, China;
| |
Collapse
|
42
|
Hurley NC, Spatz ES, Krumholz HM, Jafari R, Mortazavi BJ. A Survey of Challenges and Opportunities in Sensing and Analytics for Risk Factors of Cardiovascular Disorders. ACM TRANSACTIONS ON COMPUTING FOR HEALTHCARE 2021; 2:9. [PMID: 34337602 PMCID: PMC8320445 DOI: 10.1145/3417958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2019] [Accepted: 08/01/2020] [Indexed: 10/22/2022]
Abstract
Cardiovascular disorders cause nearly one in three deaths in the United States. Short- and long-term care for these disorders is often determined in short-term settings. However, these decisions are made with minimal longitudinal and long-term data. To overcome this bias towards data from acute care settings, improved longitudinal monitoring for cardiovascular patients is needed. Longitudinal monitoring provides a more comprehensive picture of patient health, allowing for informed decision making. This work surveys sensing and machine learning in the field of remote health monitoring for cardiovascular disorders. We highlight three needs in the design of new smart health technologies: (1) need for sensing technologies that track longitudinal trends of the cardiovascular disorder despite infrequent, noisy, or missing data measurements; (2) need for new analytic techniques designed in a longitudinal, continual fashion to aid in the development of new risk prediction techniques and in tracking disease progression; and (3) need for personalized and interpretable machine learning techniques, allowing for advancements in clinical decision making. We highlight these needs based upon the current state of the art in smart health technologies and analytics. We then discuss opportunities in addressing these needs for development of smart health technologies for the field of cardiovascular disorders and care.
Collapse
|
43
|
Estimating Surgical Blood Loss Volume Using Continuously Monitored Vital Signs. SENSORS 2020; 20:s20226558. [PMID: 33212858 PMCID: PMC7698368 DOI: 10.3390/s20226558] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/13/2020] [Accepted: 11/16/2020] [Indexed: 11/17/2022]
Abstract
Background: There are currently no effective and accurate blood loss volume (BLV) estimation methods that can be implemented in operating rooms. To improve the accuracy and reliability of BLV estimation and facilitate clinical implementation, we propose a novel estimation method using continuously monitored photoplethysmography (PPG) and invasive arterial blood pressure (ABP). Methods: Forty anesthetized York Pigs (31.82 ± 3.52 kg) underwent a controlled hemorrhage at 20 mL/min until shock development was included. Machine-learning-based BLV estimation models were proposed and tested on normalized features derived by vital signs. Results: The results showed that the mean ± standard deviation (SD) for estimating BLV against the reference BLV of our proposed random-forest-derived BLV estimation models using PPG and ABP features, as well as the combination of ABP and PPG features, were 11.9 ± 156.2, 6.5 ± 161.5, and 7.0 ± 139.4 mL, respectively. Compared with traditional hematocrit computation formulas (estimation error: 102.1 ± 313.5 mL), our proposed models outperformed by nearly 200 mL in SD. Conclusion: This is the first attempt at predicting quantitative BLV from noninvasive measurements. Normalized PPG features are superior to ABP in accurately estimating early-stage BLV, and normalized invasive ABP features could enhance model performance in the event of a massive BLV.
Collapse
|
44
|
Liu Z, Zhou B, Li Y, Tang M, Miao F. Continuous Blood Pressure Estimation From Electrocardiogram and Photoplethysmogram During Arrhythmias. Front Physiol 2020; 11:575407. [PMID: 33013491 PMCID: PMC7509183 DOI: 10.3389/fphys.2020.575407] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 08/13/2020] [Indexed: 12/02/2022] Open
Abstract
Objective Continuous blood pressure (BP) provides valuable information for the disease management of patients with arrhythmias. The traditional intra-arterial method is too invasive for routine healthcare settings, whereas cuff-based devices are inferior in reliability and comfortable for long-term BP monitoring during arrhythmias. The study aimed to investigate an indirect method for continuous and cuff-less BP estimation based on electrocardiogram (ECG) and photoplethysmogram (PPG) signals during arrhythmias and to test its reliability for the determination of BP using invasive BP (IBP) as reference. Methods Thirty-five clinically stable patients (15 with ventricular arrhythmias and 20 with supraventricular arrhythmias) who had undergone radiofrequency ablation were enrolled in this study. Their ECG, PPG, and femoral arterial IBP signals were simultaneously recorded with a multi-parameter monitoring system. Fifteen features that have the potential ability in indicating beat-to-beat BP changes during arrhythmias were extracted from the ECG and PPG signals. Four machine learning algorithms, decision tree regression (DTR), support vector machine regression (SVR), adaptive boosting regression (AdaboostR), and random forest regression (RFR), were then implemented to develop the BP models. Results The results showed that the mean value ± standard deviation of root mean square error for the estimated systolic BP (SBP), diastolic BP (DBP) with the RFR model against the reference in all patients were 5.87 ± 3.13 and 3.52 ± 1.38 mmHg, respectively, which achieved the best performance among all the models. Furthermore, the mean error ± standard deviation of error between the estimated SBP and DBP with the RFR model against the reference in all patients were −0.04 ± 6.11 and 0.11 ± 3.62 mmHg, respectively, which complied with the Association for the Advancement of Medical Instrumentation and the British Hypertension Society (Grade A) standards. Conclusion The results indicated that the utilization of ECG and PPG signals has the potential to enable cuff-less and continuous BP estimation in an indirect way for patients with arrhythmias.
Collapse
Affiliation(s)
- ZengDing Liu
- Chinese Academy of Sciences Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Shenzhen, China.,Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Bin Zhou
- State Key Lab of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Ye Li
- Chinese Academy of Sciences Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Shenzhen, China.,Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Min Tang
- State Key Lab of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Fen Miao
- Chinese Academy of Sciences Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Shenzhen, China.,Joint Engineering Research Center for Health Big Data Intelligent Analysis Technology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| |
Collapse
|
45
|
Pandit JA, Lores E, Batlle D. Cuffless Blood Pressure Monitoring: Promises and Challenges. Clin J Am Soc Nephrol 2020; 15:1531-1538. [PMID: 32680913 PMCID: PMC7536750 DOI: 10.2215/cjn.03680320] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Current BP measurements are on the basis of traditional BP cuff approaches. Ambulatory BP monitoring, at 15- to 30-minute intervals usually over 24 hours, provides sufficiently continuous readings that are superior to the office-based snapshot, but this system is not suitable for frequent repeated use. A true continuous BP measurement that could collect BP passively and frequently would require a cuffless method that could be worn by the patient, with the data stored electronically much the same way that heart rate and heart rhythm are already done routinely. Ideally, BP should be measured continuously and frequently during diverse activities during both daytime and nighttime in the same subject by means of novel devices. There is increasing excitement for newer methods to measure BP on the basis of sensors and algorithm development. As new devices are refined and their accuracy is improved, it will be possible to better assess masked hypertension, nocturnal hypertension, and the severity and variability of BP. In this review, we discuss the progression in the field, particularly in the last 5 years, ending with sensor-based approaches that incorporate machine learning algorithms to personalized medicine.
Collapse
Affiliation(s)
- Jay A Pandit
- Division of Cardiology, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Enrique Lores
- Division of Nephrology and Hypertension, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Daniel Batlle
- Division of Nephrology and Hypertension, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| |
Collapse
|
46
|
Liu Z, Miao F, Wang R, Liu J, Wen B, Li Y. Cuff-less Blood Pressure Measurement Based on Deep Convolutional Neural Network. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:3775-3778. [PMID: 31946696 DOI: 10.1109/embc.2019.8856588] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Cuff-less blood pressure (BP) monitoring is increasingly being needed for cardiovascular events management in clinical. Many of the existing methods, however, are based on manual feature extraction, which cannot characterize the complex relationship between the physiological signals and BP. In this study, the 16-layer VGGNet was used to construct cuff-less BP from electrocardiogram (ECG) and pressure pulse wave (PPW) signals, with no need extract features from raw signals. The deep network architecture has the ability of automatic feature learning, and the learned features are the higher-level abstract description of low-level raw physiological signals. Eight-nine middle-aged and elderly subjects were enrolled to evaluate the performance of the proposed BP estimation method, with oscillometric technique-based BP as a reference. Experimental results indicate that the proposed method had a commendable accuracy in BP estimation, with a correlation coefficient of 0.91 and an estimation error of -2.06 ± 6.89 mmHg for systolic BP, and 0.89 and -4.66 ± 4.91 mmHg for diastolic BP. This study shows that the proposed method provided a potential novel insight for the cuff-less BP estimation.
Collapse
|
47
|
Ibrahim B, Jafari R. Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:1723-1735. [PMID: 31603828 PMCID: PMC7028300 DOI: 10.1109/tbcas.2019.2946661] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Continuous and beat-to-beat monitoring of blood pressure (BP), compared to office-based BP measurement, provides significant advantages in predicting future cardiovascular disease. Traditional BP measurement methods are based on a cuff, which is bulky, obtrusive and not applicable to continuous monitoring. Measurement of pulse transit time (PTT) is one of the prominent cuffless methods for continuous BP monitoring. PTT is the time taken by the pressure pulse to travel between two points in an arterial vessel, which is correlated with the BP. In this paper, we present a new cuffless BP method using an array of wrist-worn bio-impedance sensors placed on the radial and the ulnar arteries of the wrist to monitor the arterial pressure pulse from the blood volume changes at each sensor site. BP is accurately estimated by using AdaBoost regression model based on selected arterial pressure pulse features such as transit time, amplitude and slope of the pressure pulse, which are dependent on the cardiac activity and the vascular properties of the wrist arteries. A separate model is developed for each subject based on calibration data to capture the individual variations of BP parameters. In this pilot study, data was collected from 10 healthy participants with age ranges from 18 to 30 years after exercising using our custom low-noise bio-impedance sensing hardware. Post-exercise BP was accurately estimated with an average correlation coefficient and root mean square error (RMSE) of 0.77 and 2.6 mmHg for the diastolic BP and 0.86 and 3.4 mmHg for the systolic BP.
Collapse
|
48
|
Shin J. Evening blood pressure rise, from myth to reality. J Clin Hypertens (Greenwich) 2019; 21:1682-1683. [PMID: 31566886 PMCID: PMC8030563 DOI: 10.1111/jch.13708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Jinho Shin
- Division of CardiologyDepartment of Internal MedicineHanyang University College of MedicineSeoulSouth Korea
| |
Collapse
|