1
|
Sopic D, Teijeiro T, Atienza D, Aminifar A, Ryvlin P. Personalized seizure signature: An interpretable approach to false alarm reduction for long-term epileptic seizure detection. Epilepsia 2023; 64 Suppl 4:S23-S33. [PMID: 35113451 DOI: 10.1111/epi.17176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 01/13/2022] [Accepted: 01/14/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVE Long-term automatic detection of focal seizures remains one of the major challenges in epilepsy due to the unacceptably high number of false alarms from state-of-the-art methods. Our aim was to investigate to what extent a new patient-specific approach based on similarly occurring morphological electroencephalographic (EEG) signal patterns could be used to distinguish seizures from nonseizure events, as well as to estimate its maximum performance. METHODS We evaluated our approach on >5500 h of long-term EEG recordings using two public datasets: the PhysioNet.org Children's Hospital Boston-Massachusetts Institute of Technology (CHB-MIT) Scalp EEG database and the EPILEPSIAE European epilepsy database. We visually identified a set of similarly occurring morphological patterns (seizure signature) seen simultaneously over two different EEG channels, and within two randomly selected seizures from each individual. The same seizure signature was then searched for in the entire recording from the same patient using dynamic time warping (DTW) as a similarity metric, with a threshold set to reflect the maximum sensitivity our algorithm could achieve without false alarm. RESULTS At a DTW threshold providing no false alarm during the entire recordings, the mean seizure detection sensitivity across patients was 84%, including 96% for the CHB-MIT database and 74% for the European epilepsy database. A 100% sensitivity was reached in 50% of patients, including 79% from the CHB-MIT database and 27% from the European epilepsy database. The median latency from seizure onset to its detection was 17 ± 10 s, with 84% of seizures being detected within 40 s. SIGNIFICANCE Personalized EEG signature combined with DTW appears to be a promising method to detect ictal events from a limited number of EEG channels with high sensitivity despite low rate of false alarms, high degree of interpretability, and low computational complexity, compatible with its future use in wearable devices.
Collapse
Affiliation(s)
- Dionisije Sopic
- Embedded Systems Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne, Switzerland
| | - Tomas Teijeiro
- Embedded Systems Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne, Switzerland
| | - David Atienza
- Embedded Systems Laboratory, Swiss Federal Institute of Technology Lausanne (EPFL), Lausanne, Switzerland
| | - Amir Aminifar
- Department of Electrical and Information Technology, Lund University, Lund, Sweden
| | - Philippe Ryvlin
- Department of Clinical Neurosciences, Neurology Service, Lausanne University Hospital (Vaud University Hospital Center), University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
2
|
Tripathi PM, Kumar A, Kumar M, Komaragiri RS. Automatic seizure detection and classification using super-resolution superlet transform and deep neural network -A preprocessing-less method. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107680. [PMID: 37459774 DOI: 10.1016/j.cmpb.2023.107680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 06/07/2023] [Accepted: 06/14/2023] [Indexed: 08/29/2023]
Abstract
CONTEXT Epilepsy, characterized by recurrent seizures, is a chronic brain disease that affects approximately 50 million. Recurrent seizures characterize it. A seizure, a burst of uncontrolled electrical activity between brain cells, results in temporary changes in behavior, level of consciousness, and involuntary movements. An accurate prediction of seizures can improve the standard of living in epileptic subjects. The increasing capabilities of machine learning and computer-assisted devices can detect seizures accurately with minimal human intervention. PROPOSED APPROACH This paper proposes a method to detect seizure and non-seizure events using superlet transform (SLT) and a deep convolution neural network: VGG-19. The electroencephalogram (EEG) dataset from the University of Bonn is used to validate the efficacy of the proposed method. METHODOLOGY SLT, a high-resolution time-frequency technique, converts EEG records into two-dimensional (2-D) images. SLT provides a high-resolution time-frequency representation reflecting the oscillation bursts in an EEG record. The time-frequency representations as 2-D images are fed to a pre-trained convolutional neural network: VGG-19. The last layers of VGG-19 are replaced with new layers to accommodate the different classification problems. RESULTS The proposed method achieved an accuracy of 100% for all seven seizure and non-seizure detection cases considered in this work. In the case of three and five-class classification problems, the proposed method has better accuracy than other existing methods. The CHB-MIT scalp EEG database is also used to assess the effectiveness of the proposed method, which achieved a classification accuracy of 94.3% in distinguishing between seizure and non-seizure events. CONCLUSION The results obtained using the proposed methodology show the efficacy of the proposed method in accurately detecting seizures and other brain activity with the least pre-processing and human involvement. The proposed method can assist medical practitioners by saving their effort and time.
Collapse
Affiliation(s)
- Prashant Mani Tripathi
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| | - Ashish Kumar
- School of Electronics Engineering, Vellore Institute of Technology, Chennai, Tamil Nadu, India
| | - Manjeet Kumar
- Department of Electronics and Communication Engineering, Delhi Technological University, Delhi, India.
| | - Rama S Komaragiri
- Department of Electronics and Communication Engineering, Bennett University, Greater Noida, India
| |
Collapse
|
3
|
Gelbard-Sagiv H, Pardo S, Getter N, Guendelman M, Benninger F, Kraus D, Shriki O, Ben-Sasson S. Optimizing Electrode Configurations for Wearable EEG Seizure Detection Using Machine Learning. SENSORS (BASEL, SWITZERLAND) 2023; 23:5805. [PMID: 37447653 DOI: 10.3390/s23135805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 06/15/2023] [Accepted: 06/19/2023] [Indexed: 07/15/2023]
Abstract
Epilepsy, a prevalent neurological disorder, profoundly affects patients' quality of life due to the unpredictable nature of seizures. The development of a reliable and user-friendly wearable EEG system capable of detecting and predicting seizures has the potential to revolutionize epilepsy care. However, optimizing electrode configurations for such systems, which is crucial for balancing accuracy and practicality, remains to be explored. This study addresses this gap by developing a systematic approach to optimize electrode configurations for a seizure detection machine-learning algorithm. Our approach was applied to an extensive database of prolonged annotated EEG recordings from 158 epilepsy patients. Multiple electrode configurations ranging from one to eighteen were assessed to determine the optimal number of electrodes. Results indicated that the performance was initially maintained as the number of electrodes decreased, but a drop in performance was found to have occurred at around eight electrodes. Subsequently, a comprehensive analysis of all eight-electrode configurations was conducted using a computationally intensive workflow to identify the optimal configurations. This approach can inform the mechanical design process of an EEG system that balances seizure detection accuracy with the ease of use and portability. Additionally, this framework holds potential for optimizing hardware in other machine learning applications. The study presents a significant step towards the development of an efficient wearable EEG system for seizure detection.
Collapse
Affiliation(s)
| | - Snir Pardo
- NeuroHelp Ltd., Ramat-Gan 5252181, Israel
| | - Nir Getter
- NeuroHelp Ltd., Ramat-Gan 5252181, Israel
- Department of Cognitive and Brain Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | - Miriam Guendelman
- NeuroHelp Ltd., Ramat-Gan 5252181, Israel
- Department of Cognitive and Brain Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | - Felix Benninger
- Department of Neurology, Rabin Medical Center, Beilinson Hospital, Petach Tikva 4941492, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Dror Kraus
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Department of Pediatric Neurology, Schneider Children's Medical Center of Israel, Petach Tikva 4920235, Israel
| | - Oren Shriki
- NeuroHelp Ltd., Ramat-Gan 5252181, Israel
- Department of Cognitive and Brain Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel
| | | |
Collapse
|
4
|
Khosroazad S, Abedi A, Hayes MJ. Sleep Signal Analysis for Early Detection of Alzheimer's Disease and Related Dementia (ADRD). IEEE J Biomed Health Inform 2023; 27:2264-2275. [PMID: 37018587 PMCID: PMC10243301 DOI: 10.1109/jbhi.2023.3235391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE Alzheimer's Disease and Related Dementia (ADRD) is growing at alarming rates, putting research and development of diagnostic methods at the forefront of the biomedical research community. Sleep disorder has been proposed as an early sign of Mild Cognitive Impairment (MCI) in Alzheimer's disease. Although several clinical studies have been conducted to assess sleep and association with early MCI, reliable and efficient algorithms to detect MCI in home-based sleep studies are needed in order to address both healthcare costs and patient discomfort in hospital/lab-based sleep studies. METHODS In this paper, an innovative MCI detection method is proposed using an overnight recording of movements associated with sleep combined with advanced signal processing and artificial intelligence. A new diagnostic parameter is introduced which is extracted from the correlation between high frequency, sleep-related movements and respiratory changes during sleep. The newly defined parameter, Time-Lag (TL), is proposed as a distinguishing criterion that indicates movement stimulation of brainstem respiratory regulation that may modulate hypoxemia risk during sleep and serve as an effective parameter for early detection of MCI in ADRD. By implementing Neural Networks (NN) and Kernel algorithms with choosing TL as the principle component in MCI detection, high sensitivity (86.75% for NN and 65% for Kernel method), specificity (89.25% and 100%), and accuracy (88% and 82.5%) have been achieved.
Collapse
|
5
|
Shivaraja TR, Remli R, Kamal N, Wan Zaidi WA, Chellappan K. Assessment of a 16-Channel Ambulatory Dry Electrode EEG for Remote Monitoring. SENSORS (BASEL, SWITZERLAND) 2023; 23:3654. [PMID: 37050713 PMCID: PMC10098757 DOI: 10.3390/s23073654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Revised: 03/10/2023] [Accepted: 03/13/2023] [Indexed: 06/19/2023]
Abstract
Ambulatory EEGs began emerging in the healthcare industry over the years, setting a new norm for long-term monitoring services. The present devices in the market are neither meant for remote monitoring due to their technical complexity nor for meeting clinical setting needs in epilepsy patient monitoring. In this paper, we propose an ambulatory EEG device, OptiEEG, that has low setup complexity, for the remote EEG monitoring of epilepsy patients. OptiEEG's signal quality was compared with a gold standard clinical device, Natus. The experiment between OptiEEG and Natus included three different tests: eye open/close (EOC); hyperventilation (HV); and photic stimulation (PS). Statistical and wavelet analysis of retrieved data were presented when evaluating the performance of OptiEEG. The SNR and PSNR of OptiEEG were slightly lower than Natus, but within an acceptable bound. The standard deviations of MSE for both devices were almost in a similar range for the three tests. The frequency band energy analysis is consistent between the two devices. A rhythmic slowdown of theta and delta was observed in HV, whereas photic driving was observed during PS in both devices. The results validated the performance of OptiEEG as an acceptable EEG device for remote monitoring away from clinical environments.
Collapse
Affiliation(s)
- Theeban Raj Shivaraja
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| | - Rabani Remli
- Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
- Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
| | - Noorfazila Kamal
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| | - Wan Asyraf Wan Zaidi
- Department of Medicine, Faculty of Medicine, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
- Hospital Canselor Tuanku Muhriz, Universiti Kebangsaan Malaysia, Cheras 56000, Malaysia
| | - Kalaivani Chellappan
- Department of Electrical, Electronics and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia
| |
Collapse
|
6
|
Li C, Lammie C, Dong X, Amirsoleimani A, Azghadi MR, Genov R. Seizure Detection and Prediction by Parallel Memristive Convolutional Neural Networks. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2022; 16:609-625. [PMID: 35737626 DOI: 10.1109/tbcas.2022.3185584] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
During the past two decades, epileptic seizure detection and prediction algorithms have evolved rapidly. However, despite significant performance improvements, their hardware implementation using conventional technologies, such as Complementary Metal-Oxide-Semiconductor (CMOS), in power and area-constrained settings remains a challenging task; especially when many recording channels are used. In this paper, we propose a novel low-latency parallel Convolutional Neural Network (CNN) architecture that has between 2-2,800x fewer network parameters compared to State-Of-The-Art (SOTA) CNN architectures and achieves 5-fold cross validation accuracy of 99.84% for epileptic seizure detection, and 99.01% and 97.54% for epileptic seizure prediction, when evaluated using the University of Bonn Electroencephalogram (EEG), CHB-MIT and SWEC-ETHZ seizure datasets, respectively. We subsequently implement our network onto analog crossbar arrays comprising Resistive Random-Access Memory (RRAM) devices, and provide a comprehensive benchmark by simulating, laying out, and determining hardware requirements of the CNN component of our system. We parallelize the execution of convolution layer kernels on separate analog crossbars to enable 2 orders of magnitude reduction in latency compared to SOTA hybrid Memristive-CMOS Deep Learning (DL) accelerators. Furthermore, we investigate the effects of non-idealities on our system and investigate Quantization Aware Training (QAT) to mitigate the performance degradation due to low Analog-to-Digital Converter (ADC)/Digital-to-Analog Converter (DAC) resolution. Finally, we propose a stuck weight offsetting methodology to mitigate performance degradation due to stuck [Formula: see text] memristor weights, recovering up to 32% accuracy, without requiring retraining. The CNN component of our platform is estimated to consume approximately 2.791 W of power while occupying an area of 31.255 mm2 in a 22 nm FDSOI CMOS process.
Collapse
|
7
|
Application of Deep Learning and WT-SST in Localization of Epileptogenic Zone Using Epileptic EEG Signals. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12104879] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Focal and non-focal Electroencephalogram (EEG) signals have proved to be effective techniques for identifying areas in the brain that are affected by epileptic seizures, known as the epileptogenic zones. The detection of the location of focal EEG signals and the time of seizure occurrence are vital information that help doctors treat focal epileptic seizures using a surgical method. This paper proposed a computer-aided detection (CAD) system for detecting and classifying focal and non-focal EEG signals as the manual process is time-consuming, prone to error, and tedious. The proposed technique employs time-frequency features, statistical, and nonlinear approaches to form a robust features extraction technique. Four detection and classification techniques for focal and non-focal EEG signals were proposed. (1). Combined hybrid features with Support Vector Machine (Hybrid-SVM) (2). Discrete Wavelet Transform with Deep Learning Network (DWT-DNN) (3). Combined hybrid features with DNN (Hybrid-DNN) as an optimized DNN model. Lastly, (4). A newly proposed technique using Wavelet Synchrosqueezing Transform-Deep Convolutional Neural Network (WTSST-DCNN). Prior to feeding the features to classifiers, statistical analyses, including t-tests, were deployed to obtain relevant and significant features at each approach. The proposed feature extraction technique and classification proved effective and suitable for smart Internet of Medical Things (IoMT) devices as performance parameters of accuracy, sensitivity, and specificity are higher than recently related works with a value of 99.7%, 99.5%, and 99.7% respectively.
Collapse
|
8
|
Nanopower Integrated Gaussian Mixture Model Classifier for Epileptic Seizure Prediction. Bioengineering (Basel) 2022; 9:bioengineering9040160. [PMID: 35447720 PMCID: PMC9028754 DOI: 10.3390/bioengineering9040160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/01/2022] [Accepted: 04/04/2022] [Indexed: 11/17/2022] Open
Abstract
This paper presents a new analog front-end classification system that serves as a wake-up engine for digital back-ends, targeting embedded devices for epileptic seizure prediction. Predicting epileptic seizures is of major importance for the patient’s quality of life as they can lead to paralyzation or even prove fatal. Existing solutions rely on power hungry embedded digital inference engines that typically consume several μW or even mW. To increase the embedded device’s autonomy, a new approach is presented combining an analog feature extractor with an analog Gaussian mixture model-based binary classifier. The proposed classification system provides an initial, power-efficient prediction with high sensitivity to switch on the digital engine for the accurate evaluation. The classifier’s circuit is chip-area efficient, operating with minimal power consumption (180 nW) at low supply voltage (0.6 V), allowing long-term continuous operation. Based on a real-world dataset, the proposed system achieves 100% sensitivity to guarantee that all seizures are predicted and good specificity (69%), resulting in significant power reduction of the digital engine and therefore the total system. The proposed classifier was designed and simulated in a TSMC 90 nm CMOS process, using the Cadence IC suite.
Collapse
|
9
|
Yan X, Yang D, Lin Z, Vucetic B. Significant Low-dimensional Spectral-temporal Features for Seizure Detection. IEEE Trans Neural Syst Rehabil Eng 2022; 30:668-677. [PMID: 35245199 DOI: 10.1109/tnsre.2022.3156931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Absence seizure as a generalized onset seizure, simultaneously spreading seizure to both sides of the brain, involves around ten-second sudden lapses of consciousness. It common occurs in children than adults, which affects living quality even threats lives. Absence seizure can be confused with inattentive attention-deficit hyperactivity disorder since both have similar symptoms, such as inattention and daze. Therefore, it is necessary to detect absence seizure onset. However, seizure onset detection in electroencephalography (EEG) signals is a challenging task due to the non-stereotyped seizure activities as well as their stochastic and non-stationary characteristics in nature. Joint spectral-temporal features are believed to contain sufficient and powerful feature information for absence seizure detection. However, the resulting high-dimensional features involve redundant information and require heavy computational load. Here, we discover significant low-dimensional spectral-temporal features in terms of mean-standard deviation of wavelet transform coefficient (MS-WTC), based on which a novel absence seizure detection framework is developed. The EEG signals are transformed into the spectral-temporal domain, with their low-dimensional features fed into a convolutional neural network. Superior detection performance is achieved on the widely-used benchmark dataset as well as a clinical dataset from the Chinese 301 Hospital. For the former, seven classification tasks were evaluated with the accuracy from 99.8% to 100.0%, while for the latter, the method achieved a mean accuracy of 94.7%, overwhelming other methods with low-dimensional temporal and spectral features. Experimental results on two seizure datasets demonstrate reliability, efficiency and stability of our proposed MS-WTC method, validating the significance of the extracted low-dimensional spectral-temporal features.
Collapse
|
10
|
Nielsen JM, Rades D, Kjaer TW. Wearable electroencephalography for ultra-long-term seizure monitoring: a systematic review and future prospects. Expert Rev Med Devices 2021; 18:57-67. [PMID: 34836477 DOI: 10.1080/17434440.2021.2012152] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION : Wearable electroencephalography (EEG) for objective seizure counting might transform the clinical management of epilepsy. Non-EEG modalities have been validated for the detection of convulsive seizures, but there is still an unmet need for the detection of non-convulsive seizures. AREAS COVERED : The main objective of this systematic review was to explore the current status on wearable surface- and subcutaneous EEG for long-term seizure monitoring in epilepsy. We included 17 studies and evaluated the progress on the field, including device specifications, intended populations, and main results on the published studies including diagnostic accuracy measures. Furthermore, we examine the hurdles for widespread clinical implementation. This systematic review and expert opinion both consults the PRISMA guidelines and reflects on the future perspectives of this emerging field. EXPERT OPINION : Wearable EEG for long-term seizure monitoring is an emerging field, with plenty of proposed devices and proof-of-concept clinical validation studies. The possible implications of these devices are immense including objective seizure counting and possibly forecasting. However, the true clinical value of the devices, including effects on patient important outcomes and clinical decision making is yet to be unveiled and large-scale clinical validation trials are called for.
Collapse
Affiliation(s)
- Jonas Munch Nielsen
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| | - Dirk Rades
- Department of Radiation Oncology, University of Lübeck, Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| | - Troels Wesenberg Kjaer
- Department of Neurology, Zealand University Hospital, Region Sjælland. Vestermarksvej 11, 4000 Roskilde, Denmark.,Department of Clinical Medicine, University of Copenhagen, Blegdamsvej 3B, 2200 Copenhagen N, Denmark
| |
Collapse
|
11
|
Tatum WO, Desai N, Feyissa A. Ambulatory EEG: Crossing the divide during a pandemic. Epilepsy Behav Rep 2021; 16:100500. [PMID: 34778740 PMCID: PMC8578031 DOI: 10.1016/j.ebr.2021.100500] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2021] [Revised: 09/02/2021] [Accepted: 09/06/2021] [Indexed: 01/07/2023] Open
Abstract
The COVID-19 pandemic forced temporary closure of epilepsy monitoring units across the globe due to potential hospital-based contagion. As COVID-19 exposures and deaths continues to surge in the United States and around the world, other types of long-term EEG monitoring have risen to fill the gap and minimize hospital exposure. AEEG has high yield compared to standard EEG. Prolonged audio-visual video-EEG capability can record events and epileptiform activity with quality like inpatient video-EEG monitoring. Technological advances in AEEG using miniaturized hardware and wireless secure transmission have evolved to small portable devices that are perfect for people forced to stay at home during the pandemic. Application of seizure detection algorithms and Cloud-based storage with real-time access provides connectivity to AEEG interpreters during prolonged "shut-down". In this article we highlight the benefits of AEEG as an alternative to diagnostic inpatient VEM during the paradigm shift to mobile heath forced by the Coronavirus.
Collapse
Affiliation(s)
| | - Nimit Desai
- Department of Neurology, Medical University of South Carolina, Charleston, SC, USA
| | | |
Collapse
|
12
|
de Bruin B, Singh K, Wang Y, Huisken J, de Gyvez JP, Corporaal H. Multi-Level Optimization of an Ultra-Low Power BrainWave System for Non-Convulsive Seizure Detection. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:1107-1121. [PMID: 34665740 DOI: 10.1109/tbcas.2021.3120965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We present a systematic evaluation and optimization of a complex bio-medical signal processing application on the BrainWave prototype system, targeted towards ambulatory EEG monitoring within a tiny power budget of 1 mW. The considered BrainWave processor is completely programmable, while maintaining energy-efficiency by means of a Coarse-Grained Reconfigurable Array (CGRA). This is demonstrated through the mapping and evaluation of a state-of-the-art non-convulsive epileptic seizure detection algorithm, while ensuring real-time operation and seizure detection accuracy. Exploiting the CGRA leads to an energy reduction of 73.1%, compared to a highly tuned software implementation (SW-only). A total of 9 complex kernels were benchmarked on the CGRA, resulting in an average 4.7 × speedup and average 4.4 × energy savings over highly tuned SW-only implementations. The BrainWave processor is implemented in 28-nm FDSOI technology with 80 kB of Foundry-provided SRAM. By exploiting near-threshold computing for the logic and voltage-stacking to minimize on-chip voltage-conversion overhead, additional 15.2% and 19.5% energy savings are obtained, respectively. At the Minimum-Energy-Point (MEP) (223 μW, 8 MHz) we report a measured state-of-the-art 90.6% system conversion efficiency, while executing the epileptic seizure detection in real-time.
Collapse
|
13
|
Shum J, Friedman D. Commercially available seizure detection devices: A systematic review. J Neurol Sci 2021; 428:117611. [PMID: 34419933 DOI: 10.1016/j.jns.2021.117611] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 10/20/2022]
Abstract
IMPORTANCE Epilepsy can be associated with significant morbidity and mortality. Seizure detection devices could be invaluable tools for both people with epilepsy, their caregivers, and clinicians as they could alert caretakers about seizures, reduce the risk of sudden unexpected death in epilepsy, and provide objective and more reliable seizure tracking to guide treatment decisions or monitor outcomes in clinical trials. OBJECTIVE To synthesize the characteristics of commercial seizure detection tools/devices currently available. METHODS We performed a systematic search utilizing a diverse set of resources to identify commercially available seizure detection products for consumer use. Performance data was obtained through a systematic review on commercially available products. OBSERVATIONS We identified 23 products marketed for seizure detection/alerting. Devices utilize a variety of mechanisms to detect seizures, including movement detectors, autonomic change detectors, electroencephalogram (EEG) based detectors, and other mechanisms (audio). The optimal device for a person with epilepsy depends on a variety of factors including the main purpose of the device, their age, seizure type and personal preferences. Only 8 devices have published peer-reviewed performance data and the majority for tonic-clonic seizures. An informed conversation between the clinician and the patient can help guide if a seizure detection device is appropriate. CONCLUSIONS AND RELEVANCE Seizure detection devices have a potential to reduce morbidity and mortality for certain people with epilepsy. Clinicians should be familiar with the characteristics of commercially available devices to best counsel their patients on whether a seizure detection device may be beneficial and what the optimal devices may be.
Collapse
Affiliation(s)
- Jennifer Shum
- Department of Neurology, Comprehensive Epilepsy Center, New York University Gross School of Medicine, New York, NY, USA.
| | - Daniel Friedman
- Department of Neurology, Comprehensive Epilepsy Center, New York University Gross School of Medicine, New York, NY, USA
| |
Collapse
|
14
|
Shahbakhti M, Rodrigues AS, Augustyniak P, Broniec-Wójcik A, Sološenko A, Beiramvand M, Marozas V. SWT-kurtosis based algorithm for elimination of electrical shift and linear trend from EEG signals. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2020.102373] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Shahbakhti M, Beiramvand M, Nazari M, Broniec-Wojcik A, Augustyniak P, Rodrigues AS, Wierzchon M, Marozas V. VME-DWT: An Efficient Algorithm for Detection and Elimination of Eye Blink From Short Segments of Single EEG Channel. IEEE Trans Neural Syst Rehabil Eng 2021; 29:408-417. [PMID: 33497337 DOI: 10.1109/tnsre.2021.3054733] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Recent advances in development of low-cost single-channel electroencephalography (EEG) headbands have opened new possibilities for applications in health monitoring and brain-computer interface (BCI) systems. These recorded EEG signals, however, are often contaminated by eye blink artifacts that can yield the fallacious interpretation of the brain activity. This paper proposes an efficient algorithm, VME-DWT, to remove eye blinks in a short segment of the single EEG channel. METHOD The proposed algorithm: (a) locates eye blink intervals using Variational Mode Extraction (VME) and (b) filters only contaminated EEG interval using an automatic Discrete Wavelet Transform (DWT) algorithm. The performance of VME-DWT is compared with an automatic Variational Mode Decomposition (AVMD) and a DWT-based algorithms, proposed for suppressing eye blinks in a short segment of the single EEG channel. RESULTS The VME-DWT detects and filters 95% of the eye blinks from the contaminated EEG signals with SNR ranging from -8 to +3 dB. The VME-DWT shows superiority to the AVMD and DWT with the higher mean value of correlation coefficient (0.92 vs. 0.83, 0.58) and lower mean value of RRMSE (0.42 vs. 0.59, 0.87). SIGNIFICANCE The VME-DWT can be a suitable algorithm for removal of eye blinks in low-cost single-channel EEG systems as it is: (a) computationally-efficient, the contaminated EEG signal is filtered in millisecond time resolution, (b) automatic, no human intervention is required, (c) low-invasive, EEG intervals without contamination remained unaltered, and (d) low-complexity, without need to the artifact reference.
Collapse
|
16
|
Tang FG, Liu Y, Li Y, Peng ZW. A unified multi-level spectral–temporal feature learning framework for patient-specific seizure onset detection in EEG signals. Knowl Based Syst 2020. [DOI: 10.1016/j.knosys.2020.106152] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
17
|
Internet of things in medicine: A systematic mapping study. J Biomed Inform 2020; 103:103383. [PMID: 32044417 DOI: 10.1016/j.jbi.2020.103383] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Revised: 01/28/2020] [Accepted: 02/01/2020] [Indexed: 12/26/2022]
Abstract
CONTEXT The current studies on IoT in healthcare have reviewed the uses of this technology in a combination of healthcare domains, including nursing, rehabilitation sciences, ambient assisted living (AAL), medicine, etc. However, no review study has scrutinized IoT advances exclusively in medicine irrespective of other healthcare domains. OBJECTIVES The purpose of the current study was to identify and map the current IoT developments in medicine through providing graphical/tabular classifications on the current experimental and practical IoT information in medicine, the involved medical sub-fields, the locations of IoT use in medicine, and the bibliometric information about IoT research articles. METHODS In this systematic mapping study, the studies published between 2000 and 2018 in major online scientific databases, including IEEE Xplore, Web of Science, Scopus, and PubMed were screened. A total of 3679 papers were found from which 89 papers were finally selected based on specific inclusion/exclusion criteria. RESULTS While the majority of medical IoT studies were experimental and prototyping in nature, they generally reported that home was the most popular place for medical IoT applications. It was also found that neurology, cardiology, and psychiatry/psychology were the medical sub-fields receiving the most IoT attention. Bibliometric analysis showed that IEEE Internet of Things Journal has published the most influential IoT articles. India, China and the United States were found to be the most involved countries in medical IoT research. CONCLUSIONS Although IoT has not yet been employed in some medical sub-fields, recent substantial surge in the number of medical IoT studies will most likely lead to the engagement of more medical sub-fields in the years to come. IoT literature also shows that the ambiguity of assigning a variety of terms to IoT, namely system, platform, device, tool, etc., and the interchangeable uses of these terms require a taxonomy study to investigate the precise definition of these terms. Other areas of research have also been mentioned at the end of this article.
Collapse
|
18
|
Dümpelmann M. Early seizure detection for closed loop direct neurostimulation devices in epilepsy. J Neural Eng 2019; 16:041001. [DOI: 10.1088/1741-2552/ab094a] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
19
|
Zabihi M, Kiranyaz S, Jantti V, Lipping T, Gabbouj M. Patient-Specific Seizure Detection Using Nonlinear Dynamics and Nullclines. IEEE J Biomed Health Inform 2019; 24:543-555. [PMID: 30932854 DOI: 10.1109/jbhi.2019.2906400] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Nonlinear dynamics has recently been extensively used to study epilepsy due to the complex nature of the neuronal systems. This study presents a novel method that characterizes the dynamic behavior of pediatric seizure events and introduces a systematic approach to locate the nullclines on the phase space when the governing differential equations are unknown. Nullclines represent the locus of points in the solution space where the components of the velocity vectors are zero. A simulation study over 5 benchmark nonlinear systems with well-known differential equations in three-dimensional exhibits the characterization efficiency and accuracy of the proposed approach that is solely based on the reconstructed solution trajectory. Due to their unique characteristics in the nonlinear dynamics of epilepsy, discriminative features can be extracted based on the nullclines concept. Using a limited training data (only 25% of each EEG record) in order to mimic the real-world clinical practice, the proposed approach achieves 91.15% average sensitivity and 95.16% average specificity over the benchmark CHB-MIT dataset. Together with an elegant computational efficiency, the proposed approach can, therefore, be an automatic and reliable solution for patient-specific seizure detection in long EEG recordings.
Collapse
|