1
|
Brioschi ML, Dalmaso Neto C, Toledo MD, Neves EB, Vargas JVC, Teixeira MJ. Infrared image method for possible COVID-19 detection through febrile and subfebrile people screening. J Therm Biol 2023; 112:103444. [PMID: 36796899 PMCID: PMC9794388 DOI: 10.1016/j.jtherbio.2022.103444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Revised: 11/30/2022] [Accepted: 12/22/2022] [Indexed: 12/29/2022]
Abstract
This study proposed an infrared image-based method for febrile and subfebrile people screening to comply with the society need for alternative, quick response, and effective methods for COVID-19 contagious people screening. The methodology consisted of: (i) Developing a method based on facial infrared imaging for possible COVID-19 early detection in people with and without fever (subfebrile state); (ii) Using 1206 emergency room (ER) patients to develop an algorithm for general application of the method, and (iii) Testing the method and algorithm effectiveness in 2558 cases (RT-qPCR tested for COVID-19) from 227,261 workers evaluations in five different countries. Artificial intelligence was used through a convolutional neural network (CNN) to develop the algorithm that took facial infrared images as input and classified the tested individuals in three groups: fever (high risk), subfebrile (medium risk), and no fever (low risk). The results showed that suspicious and confirmed COVID-19 (+) cases characterized by temperatures below the 37.5 °C fever threshold were identified. Also, average forehead and eye temperatures greater than 37.5 °C were not enough to detect fever similarly to the proposed CNN algorithm. Most RT-qPCR confirmed COVID-19 (+) cases found in the 2558 cases sample (17 cases/89.5%) belonged to the CNN selected subfebrile group. The COVID-19 (+) main risk factor was to be in the subfebrile group, in comparison to age, diabetes, high blood pressure, smoking and others. In sum, the proposed method was shown to be a potentially important new tool for COVID-19 (+) people screening for air travel and public places in general.
Collapse
Affiliation(s)
- Marcos Leal Brioschi
- Medical Thermology and Thermography Specialization, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, HCFMUSP, São Paulo, SP, 01246-903, Brazil
| | - Carlos Dalmaso Neto
- Medical Thermology and Thermography Specialization, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, HCFMUSP, São Paulo, SP, 01246-903, Brazil; Mechanical Engineering Post-Graduation Program, Mechanical Engineering Department, Universidade Federal do Paraná, UFPR, Curitiba, PR, 81531-980, Brazil.
| | - Marcos de Toledo
- Medical Thermology and Thermography Specialization, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, HCFMUSP, São Paulo, SP, 01246-903, Brazil
| | - Eduardo Borba Neves
- Biomedical Engineering Post-Graduation Program, Universidade Tecnológica Federal do Paraná, UTFPR, Curitiba, PR, 82590-300, Brazil
| | - José Viriato Coelho Vargas
- Mechanical Engineering Post-Graduation Program, Mechanical Engineering Department, Universidade Federal do Paraná, UFPR, Curitiba, PR, 81531-980, Brazil
| | - Manoel Jacobsen Teixeira
- Neurology and Neurosurgery Department, Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo – HCFMUSP, São Paulo, SP, 01246-903, Brazil
| |
Collapse
|
2
|
Zhou Y, Ghassemi P, Chen M, McBride D, Casamento JP, Pfefer TJ, Wang Q. Clinical evaluation of fever-screening thermography: impact of consensus guidelines and facial measurement location. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:JBO-200193R. [PMID: 32921005 PMCID: PMC7486803 DOI: 10.1117/1.jbo.25.9.097002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Accepted: 08/27/2020] [Indexed: 05/07/2023]
Abstract
SIGNIFICANCE Infrared thermographs (IRTs) have been used for fever screening during infectious disease epidemics, including severe acute respiratory syndrome, Ebola virus disease, and coronavirus disease 2019 (COVID-19). Although IRTs have significant potential for human body temperature measurement, the literature indicates inconsistent diagnostic performance, possibly due to wide variations in implemented methodology. A standardized method for IRT fever screening was recently published, but there is a lack of clinical data demonstrating its impact on IRT performance. AIM Perform a clinical study to assess the diagnostic effectiveness of standardized IRT-based fever screening and evaluate the effect of facial measurement location. APPROACH We performed a clinical study of 596 subjects. Temperatures from 17 facial locations were extracted from thermal images and compared with oral thermometry. Statistical analyses included calculation of receiver operating characteristic (ROC) curves and area under the curve (AUC) values for detection of febrile subjects. RESULTS Pearson correlation coefficients for IRT-based and reference (oral) temperatures were found to vary strongly with measurement location. Approaches based on maximum temperatures in either inner canthi or full-face regions indicated stronger discrimination ability than maximum forehead temperature (AUC values of 0.95 to 0.97 versus 0.86 to 0.87, respectively) and other specific facial locations. These values are markedly better than the vast majority of results found in prior human studies of IRT-based fever screening. CONCLUSION Our findings provide clinical confirmation of the utility of consensus approaches for fever screening, including the use of inner canthi temperatures, while also indicating that full-face maximum temperatures may provide an effective alternate approach.
Collapse
Affiliation(s)
- Yangling Zhou
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
- University of Maryland, Department of Mechanical Engineering, Baltimore County, Maryland, United States
| | - Pejman Ghassemi
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | - Michelle Chen
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
- Johns Hopkins University, Department of Chemical and Biomolecular Engineering, Baltimore, Maryland, United States
| | - David McBride
- University of Maryland, University Health Center, College Park, Maryland, United States
| | - Jon P. Casamento
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | - T. Joshua Pfefer
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
| | - Quanzeng Wang
- Food and Drug Administration, Center for Devices and Radiological Health, Silver Spring, Maryland, United States
- Address all correspondence to Quanzeng Wang, E-mail:
| |
Collapse
|
3
|
Chen HY, Chen A, Chen C. Investigation of the Impact of Infrared Sensors on Core Body Temperature Monitoring by Comparing Measurement Sites. SENSORS 2020; 20:s20102885. [PMID: 32438729 PMCID: PMC7284737 DOI: 10.3390/s20102885] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 05/13/2020] [Accepted: 05/19/2020] [Indexed: 01/24/2023]
Abstract
Many types of thermometers have been developed to measure body temperature. Infrared thermometers (IRT) are fast, convenient and ease to use. Two types of infrared thermometers are uses to measure body temperature: tympanic and forehead. With the spread of COVID-19 coronavirus, forehead temperature measurement is used widely to screen people for the illness. The performance of this type of device and the criteria for screening are worth studying. This study evaluated the performance of two types of tympanic infrared thermometers and an industrial infrared thermometer. The results showed that these infrared thermometers provide good precision. A fixed offset between tympanic and forehead temperature were found. The measurement values for wrist temperature show significant offsets with the tympanic temperature and cannot be used to screen fevers. The standard operating procedure (SOP) for the measurement of body temperature using an infrared thermometer was proposed. The suggestion threshold for the forehead temperature is 36 °C for screening of fever. The body temperature of a person who is possibly ill is then measured using a tympanic infrared thermometer for the purpose of a double check.
Collapse
Affiliation(s)
- Hsuan-Yu Chen
- Department of Materials Science and Engineering, University of California, San Diego, CA 92093, USA;
| | - Andrew Chen
- Africa Research Center, National Chung Hsing University, Taichung 40227, Taiwan;
| | - Chiachung Chen
- Department of Bio-industrial Mechatronics Engineering, National ChungHsing University, Taichung 40227, Taiwan
- Correspondence: ; Tel.: +886-4-22857562
| |
Collapse
|
4
|
Best practices for standardized performance testing of infrared thermographs intended for fever screening. PLoS One 2018; 13:e0203302. [PMID: 30231046 PMCID: PMC6145558 DOI: 10.1371/journal.pone.0203302] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Accepted: 08/17/2018] [Indexed: 11/19/2022] Open
Abstract
Infrared (IR) modalities represent the only currently viable mass fever screening approaches for outbreaks of infectious disease pandemics such as Ebola virus disease and severe acute respiratory syndrome. Non-contact IR thermometers (NCITs) and IR thermographs (IRTs) have been used for fever screening in public areas such as airports. While NCITs remain a more popular choice than IRTs, there has been increasing evidences in the literature that IRTs can provide great accuracy in estimating body temperature if qualified systems are used and appropriate procedures are consistently applied. In this study, we addressed the issue of IRT qualification by implementing and evaluating a battery of test methods for objective, quantitative assessment of IRT performance based on a recent international standard (IEC 80601-2-59). We tested two commercial IRTs to evaluate their stability and drift, image uniformity, minimum resolvable temperature difference, and radiometric temperature laboratory accuracy. Based on these tests, we illustrated how experimental and data processing procedures could affect results, and suggested methods for clarifying and optimizing test methods. Overall, the insights into thermograph standardization and acquisition methods provided by this study may improve the utility of IR thermography and aid in comparing IRT performance, thus improving the potential for producing high quality disease pandemic countermeasures.
Collapse
|
5
|
Poursaberi A, Vana J, Mráček Š, Dvora R, Yanushkevich SN, Drahansky M, Shmerko VP, Gavrilova ML. Facial biometrics for situational awareness systems. IET BIOMETRICS 2013. [DOI: 10.1049/iet-bmt.2012.0065] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Affiliation(s)
- Ahmad Poursaberi
- ECEUniversity of Calgary2500 University Drive NWCalgaryAlbertaCanada
| | - Jan Vana
- Department of Intelligent Systems (DITS)Brno University of Technology61266BrnoCzech Republic
| | - Štěpán Mráček
- Department of Intelligent Systems (DITS)Brno University of Technology61266BrnoCzech Republic
| | - Radim Dvora
- Department of Intelligent Systems (DITS)Brno University of Technology61266BrnoCzech Republic
| | | | - Martin Drahansky
- Department of Intelligent Systems (DITS)Brno University of Technology61266BrnoCzech Republic
| | - Vlad P. Shmerko
- ECEUniversity of Calgary2500 University Drive NWCalgaryAlbertaCanada
| | | |
Collapse
|
6
|
ETEHADTAVAKOL MAHNAZ, NG EDDIEYK. BREAST THERMOGRAPHY AS A POTENTIAL NON-CONTACT METHOD IN THE EARLY DETECTION OF CANCER: A REVIEW. J MECH MED BIOL 2013. [DOI: 10.1142/s0219519413300019] [Citation(s) in RCA: 59] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This review paper discusses recent research achievements in medical thermography with concerns about the possibility of early breast cancer detection. With the advancements in infrared (IR) technology, image processing methods, and the pathophysiological-based knowledge of thermograms, IR screening is sufficiently mature to be utilized as a first-line complement to both health managing and clinical prognosis. In addition, it explains the performance and environmental conditions in identifying thermography for breast tumor imaging under strict indoor controlled environmental circumstances. An irregular thermogram is indicated as a significant biological risk marker for the presence or growth of breast tumors. Breast thermography is completely non-contact, with no form of radiation and compression. It is useful for all women of all ages, for pregnant and breastfeeding women, for women with implants, for women with dense or fibrocystic breasts, for women on hormone replacement therapy, and for pre or post menopausal women. Breast thermography is specifically worthwhile during the early stages of fast tumor growth, which is not yet recognizable by mammography as thermography is a physiological test while mammography is an anatomical one. Often, physiological changes precede anatomical changes. This early detection of irregular tissue liveliness gives breast thermography the potential to be greatly useful and economical as an imaging program and provides the opportunity to apply non-invasive treatment to reform breast tissue activity. The non-radiating nature of thermography also permits repeated images. Thus, changes can be compared over time and the results of protective approaches can be observed to ensure utmost care of breast cells.
Collapse
Affiliation(s)
- MAHNAZ ETEHADTAVAKOL
- Medical Image and Signal Processing Research Centre, Isfahan University of Medical Sciences, Isfahan 81745-319, Iran
| | - EDDIE Y. K. NG
- School of Mechanical and Aerospace Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| |
Collapse
|
7
|
Abstract
Mathematical modeling has proven to be a viable alternative for investigating the temperature distribution inside the human eye. This is due to its ability to overcome the limitations infrared (IR) thermography; the leading method in ocular temperature measurement. A wide range of mathematical studies on the ocular temperature distribution during various conditions have been published in the literature. In this paper, we carry out an in-depth review of the various mathematical models of the eye that have been developed in the past. Various problems and the implications from the mathematical predictions of these studies are discussed. The future directions of studies in ocular temperature distribution are deliberated.
Collapse
Affiliation(s)
- E. H. OOI
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| | - E. Y. K. NG
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| |
Collapse
|
8
|
Roberge RJ, Monaghan WD, Palmiero AJ, Shaffer R, Bergman MS. Infrared imaging for leak detection of N95 filtering facepiece respirators: a pilot study. Am J Ind Med 2011; 54:628-36. [PMID: 21594885 DOI: 10.1002/ajim.20970] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/25/2011] [Indexed: 11/07/2022]
Abstract
BACKGROUND This study was undertaken to determine the utility of an infrared camera (IRC) for assessing leaks around filtering facepiece respirators (FFR) during quantitative respirator fit testing. METHODS Eight subjects underwent quantitative fit testing on six N95 FFR models (48 total fit tests) while simultaneously being recorded with an IRC. RESULTS The IRC detected 49 exhalation leaks during 39 tests and no leaks in nine tests. Exhalation leaks were identified in all failed fit tests (13) and a majority (26 of 35) of passed tests. Anatomically, the nasal region and malar (cheekbone) regions accounted for 71% of identified leak sites. Fit factors for fit tests without identified exhalation leaks were significantly higher than fit tests with leaks detected by IRC (P = 0.01). CONCLUSIONS Thermal imaging using IRC can detect leaks in respiratory protective equipment and has the potential as a screening tool for assessment of the adequacy of post-donning FFR fit.
Collapse
Affiliation(s)
- Raymond J Roberge
- National Personal Protective Technology Laboratory/National Institute for Occupational Safety and Health/Centers for Disease Control and Prevention, Pittsburgh, Pennsylvania.
| | | | | | | | | |
Collapse
|
9
|
Matsui T, Hakozaki Y, Suzuki S, Usui T, Kato T, Hasegawa K, Sugiyama Y, Sugamata M, Abe S. A novel screening method for influenza patients using a newly developed non-contact screening system. J Infect 2010; 60:271-7. [PMID: 20138082 PMCID: PMC7112665 DOI: 10.1016/j.jinf.2010.01.005] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2009] [Revised: 01/20/2010] [Accepted: 01/20/2010] [Indexed: 11/16/2022]
Abstract
OBJECTIVES In places of mass gathering, rapid infection screening prior to definite diagnosis is vital during the epidemic season of a novel influenza. In order to assess the possibility of clinical application of a newly developed non-contact infection screening system, we conducted screening for influenza patients. MATERIALS AND METHODS The system is operated by a screening program via a linear discriminant analysis using non-contact derived variables, i.e., palmar pulse derived from a laser Doppler blood-flow meter, respiration rate determined by a 10-GHz microwave radar, and average facial temperature measured by thermography. The system was tested on 57 seasonal influenza (2008-2009) patients (35.7 degrees C < or = body temperature < or = 38.3 degrees C, 19-40 years) and 35 normal control subjects (35.5 degrees C < or = body temperature < or = 36.9 degrees C, 21-35 years) at the Japan Self-defense Forces Central Hospital. RESULTS A significant linear discriminant function (p < 0.001) was determined to distinguish the influenza group from the control group (Mahalanobis D-square = 6.5, classification error rate > 10%). The system had a positive predictive value (PPV) of 93%, which is higher than the PPV value (PPV < or = 65.4%) reported in the recent summary of studies using only thermography performed mainly in hospitals. CONCLUSIONS The proposed system appears promising for application in accurate screening for influenza patients at places of mass gathering.
Collapse
Affiliation(s)
- Takemi Matsui
- Department of Management Systems Engineering, Tokyo Metropolitan University, Asahigaoka 6-6, Hino, Tokyo 191-0065, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Affiliation(s)
- Eddie Y-K Ng
- School of Mechanical and Aerospace Engineering, College of Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore
| | | |
Collapse
|
11
|
Ng EYK. Is thermal scanner losing its bite in mass screening of fever due to SARS? Med Phys 2005; 32:93-7. [PMID: 15719959 PMCID: PMC7168465 DOI: 10.1118/1.1819532] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2004] [Revised: 09/17/2004] [Accepted: 09/21/2004] [Indexed: 12/02/2022] Open
Abstract
Severe acute respiratory syndrome (SARS) is a highly infectious disease caused by a coronavirus. Screening to detect a potential SARS infected person plays an important role in preventing the spread of SARS. The use of infrared thermal imaging cameras has been proposed as a noninvasive, speedy, cost effective and fairly accurate means for mass blind screening of potential SARS infected persons. Infrared thermography provides a digital image showing temperature patterns. This has been previously utilized in the detection of inflammation and nerve dysfunctions. It is believed that IR cameras can potentially be used to detect subjects with fever, the cardinal symptom of SARS, and avian influenza. The accuracy of the infrared system can, however, be affected by human, environmental, and equipment variables. It is also limited by the fact that the thermal imager measures the skin temperature and not the core body temperature. As known, the body determines a temperature as its so-called "set point" at any one time during the body temperature regulation. Fever happens if the hypothalamus detects pyrogens and then raises the set point. The time course of a typical fever can be divided into three stages. When the fever initiates, the body attempts to raise its temperature but vasoconstriction occurs to prevent heat loss through the skin. With this reason, some individuals at this stage of fever (at the rising slope and immediately after fever begins or falling slope after the fever breaks) will not be detected by the scanner if it is not designed to detect subject at the plateau of the fever (with her/his high core temperature) in particular. This paper aims to study the effectiveness of infrared systems for its application in mass blind screening to detect subjects with elevated body temperature. For this application, it is critical for thermal imagers to be able to identify febrile from normal subjects accurately. Minimizing the number of false positive and false negative cases, improves the efficiency of the screening stations. False negative results should be avoided at all costs, as letting a SARS infected person through the screening process may result in potentially catastrophic results. Various statistical methods such as linear regression, Receiver Operating Characteristics analysis, and neural networks based classification were used to analyze the temperature data collected from various sites on the face on both the frontal and side profiles. Two important conclusions were drawn from the analysis: the best region on the face to obtain temperature readings and the optimal preset threshold temperature for the thermal imager. To conclude, the current research application will remain an interest and useful for reference by both local and overseas manufacturers of thermal scanners, users, and various government and private establishments. As elevation of body temperature is a common presenting symptom for many illnesses including infectious diseases, thermal imagers are useful tools for mass screening of body temperature not only for SARS but also during other public health crisis where widespread transmission of infection is a concern.
Collapse
Affiliation(s)
- Eddie Y K Ng
- School of Mechanical and Production Engineering, College of Engineering, Nanyang Technical University, Singapore 639798, Singapore.
| |
Collapse
|