1
|
Weiser PJ, Langs G, Motyka S, Bogner W, Courvoisier S, Hoffmann M, Klauser A, Andronesi OC. WALINET: A water and lipid identification convolutional neural network for nuisance signal removal in 1 H $$ {}^1\mathrm{H} $$ MR spectroscopic imaging. Magn Reson Med 2024. [PMID: 39737778 DOI: 10.1002/mrm.30402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2024] [Revised: 10/30/2024] [Accepted: 11/26/2024] [Indexed: 01/01/2025]
Abstract
PURPOSE Proton magnetic resonance spectroscopic imaging ( 1 H $$ {}^1\mathrm{H} $$ -MRSI) provides noninvasive spectral-spatial mapping of metabolism. However, long-standing problems in whole-brain 1 H $$ {}^1\mathrm{H} $$ -MRSI are spectral overlap of metabolite peaks with large lipid signal from scalp, and overwhelming water signal that distorts spectra. Fast and effective methods are needed for high-resolution 1 H $$ {}^1\mathrm{H} $$ -MRSI to accurately remove lipid and water signals while preserving the metabolite signal. The potential of supervised neural networks for this task remains unexplored, despite their success for other MRSI processing. METHODS We introduce a deep learning method based on a modified Y-NET network for water and lipid removal in whole-brain 1 H $$ {}^1\mathrm{H} $$ -MRSI. The WALINET (WAter and LIpid neural NETwork) was compared with conventional methods such as the state-of-the-art lipid L2 regularization and Hankel-Lanczos singular value decomposition (HLSVD) water suppression. Methods were evaluated on simulated models and in vivo whole-brain MRSI using NMRSE, SNR, CRLB, and FWHM metrics. RESULTS WALINET is significantly faster and needs 8s for high-resolution whole-brain MRSI, compared with 42min for conventional HLSVD+L2. WALINET suppresses lipid and water in the brain by 25-45 and 34-53-fold, respectively. WALINET has better performance than HLSVD+L2, providing: (1) more lipid removal with 41% lower NRMSE; (2) better metabolite signal preservation with 71% lower NRMSE in simulated data; 155% higher SNR and 50% lower CRLB in in vivo data. Metabolic maps obtained by WALINET in healthy subjects and patients show better gray-/white-matter contrast with more visible structural details. CONCLUSIONS WALINET has superior performance for nuisance signal removal and metabolite quantification on whole-brain 1 H $$ {}^1\mathrm{H} $$ -MRSI compared with conventional state-of-the-art techniques. This represents a new application of deep learning for MRSI processing, with potential for automated high-throughput workflow.
Collapse
Affiliation(s)
- Paul J Weiser
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
- Computational Imaging Research Lab-Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Georg Langs
- Computational Imaging Research Lab-Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Stanislav Motyka
- High Field MR Center-Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Wolfgang Bogner
- High Field MR Center-Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Sébastien Courvoisier
- Center for Biomedical Imaging (CIBM), Geneva, Switzerland
- Department of Radiology and Medical Informatics, University of Geneva, Geneva, Switzerland
| | - Malte Hoffmann
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Antoine Klauser
- Advanced Clinical Imaging Technology, Siemens Healthineers International AG, Lausanne, Switzerland
| | - Ovidiu C Andronesi
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
2
|
Shamaei A, Starcukova J, Rizzo R, Starcuk Z. Water removal in MR spectroscopic imaging with Casorati singular value decomposition. Magn Reson Med 2024; 91:1694-1706. [PMID: 38181180 DOI: 10.1002/mrm.29959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 11/04/2023] [Accepted: 11/17/2023] [Indexed: 01/07/2024]
Abstract
PURPOSE Water removal is one of the computational bottlenecks in the processing of high-resolution MRSI data. The purpose of this work is to propose an approach to reduce the computing time required for water removal in large MRS data. METHODS In this work, we describe a singular value decomposition-based approach that uses the partial position-time separability and the time-domain linear predictability of MRSI data to reduce the computational time required for water removal. Our approach arranges MRS signals in a Casorati matrix form, applies low-rank approximations utilizing singular value decomposition, removes residual water from the most prominent left-singular vectors, and finally reconstructs the water-free matrix using the processed left-singular vectors. RESULTS We have demonstrated the effectiveness of our proposed algorithm for water removal using both simulated and in vivo data. The proposed algorithm encompasses a pip-installable tool ( https://pypi.org/project/CSVD/), available on GitHub ( https://github.com/amirshamaei/CSVD), empowering researchers to use it in future studies. Additionally, to further promote transparency and reproducibility, we provide comprehensive code for result replication. CONCLUSIONS The findings of this study suggest that the proposed method is a promising alternative to existing water removal methods due to its low processing time and good performance in removing water signals.
Collapse
Affiliation(s)
- Amirmohammad Shamaei
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
- Department of Electrical and Software Engineering, Schulich School of Engineering, University of Calgary, Calgary, Alberta, Canada
| | - Jana Starcukova
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
| | - Rudy Rizzo
- MR Methodology, Department of Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Department of Biomedical Research, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute of Translational Entrepreneurial Medicine, Bern, Switzerland
| | - Zenon Starcuk
- Institute of Scientific Instruments of the Czech Academy of Sciences, Brno, Czech Republic
| |
Collapse
|
3
|
Dziadosz M, Rizzo R, Kyathanahally SP, Kreis R. Denoising single MR spectra by deep learning: Miracle or mirage? Magn Reson Med 2023; 90:1749-1761. [PMID: 37332185 DOI: 10.1002/mrm.29762] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 05/05/2023] [Accepted: 05/28/2023] [Indexed: 06/20/2023]
Abstract
PURPOSE The inherently poor SNR of MRS measurements presents a significant hurdle to its clinical application. Denoising by machine or deep learning (DL) was proposed as a remedy. It is investigated whether such denoising leads to lower estimate uncertainties or whether it essentially reduces noise in signal-free areas only. METHODS Noise removal based on supervised DL with U-nets was implemented using simulated 1 H MR spectra of human brain in two approaches: (1) via time-frequency domain spectrograms and (2) using 1D spectra as input. Quality of denoising was evaluated in three ways: (1) by an adapted fit quality score, (2) by traditional model fitting, and (3) by quantification via neural networks. RESULTS Visually appealing spectra were obtained; hinting that denoising is well-suited for MRS. However, an adapted denoising score showed that noise removal is inhomogeneous and more efficient for signal-free areas. This was confirmed by quantitative analysis of traditional fit results as well as DL quantitation following DL denoising. DL denoising, although apparently successful as judged by mean squared errors, led to substantially biased estimates in both implementations. CONCLUSION The implemented DL-based denoising techniques may be useful for display purposes, but do not help quantitative evaluations, confirming expectations based on estimation theory: Cramér Rao lower bounds defined by the original data and the appropriate fitting model cannot be circumvented in an unbiased way for single data sets, unless additional prior knowledge can be incurred in the form of parameter restrictions/relations or applicable substates.
Collapse
Affiliation(s)
- Martyna Dziadosz
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Rudy Rizzo
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
- Graduate School for Cellular and Biomedical Sciences, University of Bern, Bern, Switzerland
| | - Sreenath P Kyathanahally
- Department System Analysis, Integrated Assessment and Modelling, Eawag - Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Roland Kreis
- MR Methodology, Department for Diagnostic and Interventional Neuroradiology, University of Bern, Bern, Switzerland
- Translational Imaging Center (TIC), Swiss Institute for Translational and Entrepreneurial Medicine, Bern, Switzerland
| |
Collapse
|
4
|
Stamatelatou A, Sima DM, van Huffel S, van Asten JJA, Heerschap A, Scheenen TWJ. Post-acquisition water-signal removal in 3D water-unsuppressed 1 H-MR spectroscopic imaging of the prostate. Magn Reson Med 2023; 89:1741-1753. [PMID: 36572967 DOI: 10.1002/mrm.29565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 11/23/2022] [Accepted: 12/08/2022] [Indexed: 12/28/2022]
Abstract
PURPOSE To develop a robust processing procedure of raw signals from water-unsuppressed MRSI of the prostate for the mapping of absolute tissue concentrations of metabolites. METHODS Water-unsuppressed 3D MRSI data were acquired from a phantom, from healthy volunteers, and a patient with prostate cancer. Signal processing included sequential computation of the modulus of the FID to remove water sidebands, a Hilbert transformation, and k-space Hamming filtering. For the removal of the water signal, we compared Löwner tensor-based blind source separation (BSS) and Hankel Lanczos singular value decomposition techniques. Absolute metabolite levels were quantified with LCModel and the results were statistically analyzed to compare the water removal methods and conventional water-suppressed MRSI. RESULTS The post-processing algorithms successfully removed the water signal and its sidebands without affecting metabolite signals. The best water removal performance was achieved by Löwner tensor-based BSS. Absolute tissue concentrations of citrate in the peripheral zone derived from water-suppressed and unsuppressed 1 H MRSI were the same and as expected from the known physiology of the healthy prostate. Maps for citrate and choline from water-unsuppressed 3D 1 H-MRSI of the prostate showed expected spatial variations in metabolite levels. CONCLUSION We developed a robust relatively simple post-processing method of water-unsuppressed MRSI of the prostate to remove the water signal. Absolute quantification using the water signal, originating from the same location as the metabolite signals, avoids the acquisition of additional reference data.
Collapse
Affiliation(s)
- Angeliki Stamatelatou
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands
| | | | - Sabine van Huffel
- STADIUS Center for Dynamical Systems, Signal Processing and Data Analytics, Department of Electrical Engineering (ESAT), Leuven, Belgium
| | - Jack J A van Asten
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands
| | - Arend Heerschap
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands
| | - Tom W J Scheenen
- Department of Medical Imaging (766), Radboud University Medical Center Nijmegen, Nijmegen, The Netherlands
| |
Collapse
|
5
|
Lin L, Považan M, Berrington A, Chen Z, Barker PB. Water removal in MR spectroscopic imaging with L2 regularization. Magn Reson Med 2019; 82:1278-1287. [PMID: 31148254 DOI: 10.1002/mrm.27824] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Revised: 04/03/2019] [Accepted: 05/01/2019] [Indexed: 12/31/2022]
Abstract
PURPOSE An L2-regularization based postprocessing method is proposed and tested for removal of residual or unsuppressed water signals in proton MR spectroscopic imaging (MRSI) data recorded from the human brain at 3T. METHODS Water signals are removed by implementation of the L2 regularization using a synthesized water-basis matrix that is orthogonal to metabolite signals of interest in the spectral dimension. Simulated spectra with variable water amplitude and in vivo brain MRSI datasets were used to demonstrate the proposed method. Results were compared with two commonly-used postprocessing methods for removing water signals. RESULTS The L2 method yielded metabolite signals that were close to true values for the simulated spectra. Residual/unsuppressed water signals in human brain short- and long-echo time MRSI datasets were efficiently removed by the proposed method allowing good quality metabolite maps to be reconstructed with minimized contamination from water signals. Significant differences of the creatine signal were observed between brain long-echo time MRSI without and with water saturation, attributable to the previously described magnetization transfer effect. CONCLUSIONS With usage of a synthesized water matrix generated based on reasonable prior knowledge about water and metabolite resonances, the L2 method is shown to be an effective way to remove water signals from MRSI of the human brain.
Collapse
Affiliation(s)
- Liangjie Lin
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland.,Department of Electronic Science, Xiamen University, Xiamen, China
| | - Michal Považan
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Adam Berrington
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | - Zhong Chen
- Department of Electronic Science, Xiamen University, Xiamen, China
| | - Peter B Barker
- Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland.,F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland
| |
Collapse
|