1
|
Yatabe M, Kripfgans O, Chan HL, Xu J, Cook J, Soki F. Ultrasonography as an additional tool to localize impacted canines. Oral Radiol 2024:10.1007/s11282-024-00769-z. [PMID: 39126535 DOI: 10.1007/s11282-024-00769-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2024] [Accepted: 07/25/2024] [Indexed: 08/12/2024]
Abstract
Canine impaction is a common dental anomaly that requires a multidisciplinary approach, from diagnosis to treatment. The regular two-dimensional (2D) radiographs are able to visualize if the tooth is impacted, but unable to specifically localize it, and determine if there are any root resorptions associated to it. The cone-beam computed tomography (CBCT) is able to three-dimensionally determine its location, aiding to the diagnosis and treatment plan. The major disadvantage is the amount of radiation that is added to the patient and can be even more significant in pediatric patients. The intra-oral ultrasound (io-US) is a new non-invasive and non-radiating real-time chairside imaging method that has the potential to aid in locating the impacted tooth. This paper presents 4 cases that required a CBCT for the location and treatment planning of impacted maxillary canines and were also scanned with intra-oral ultrasound. The images were then compared to the CBCT exam for validation of the new method. Through these cases, we highlight the capability of the io-US to locate the impacted canines. Other advantages of io-US might include evaluation of soft tissue thickness and vasculature that are important for surgical planning and execution.
Collapse
Affiliation(s)
- Marilia Yatabe
- Department of Orthodontics and Pediatric Dentistry, University of Michigan, Ann Arbor, MI, USA.
| | - Oliver Kripfgans
- Department of Radiology, University of Michigan, Michigan Medicine, Ann Arbor, MI, USA
| | - Hsun-Liang Chan
- Division of Periodontology, The Ohio State University, Columbus, OH, USA
| | - Jennifer Xu
- Department of Orthodontics and Pediatric Dentistry, University of Michigan, Ann Arbor, MI, USA
| | - Jade Cook
- Department of Orthodontics and Pediatric Dentistry, University of Michigan, Ann Arbor, MI, USA
| | - Fabiana Soki
- Department of Periodontics and Oral Medicine, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
2
|
Guo J, Wu Y, Chen L, Long S, Chen D, Ouyang H, Zhang C, Tang Y, Wang W. A perspective on the diagnosis of cracked tooth: imaging modalities evolve to AI-based analysis. Biomed Eng Online 2022; 21:36. [PMID: 35706023 PMCID: PMC9202175 DOI: 10.1186/s12938-022-01008-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 06/03/2022] [Indexed: 11/10/2022] Open
Abstract
Despite numerous clinical trials and pre-clinical developments, the diagnosis of cracked tooth, especially in the early stages, remains a challenge. Cracked tooth syndrome is often accompanied by dramatic painful responses from occlusion and temperature stimulation, which has become one of the leading causes for tooth loss in adults. Current clinical diagnostical approaches for cracked tooth have been widely investigated based on X-rays, optical light, ultrasound wave, etc. Advances in artificial intelligence (AI) development have unlocked the possibility of detecting the crack in a more intellectual and automotive way. This may lead to the possibility of further enhancement of the diagnostic accuracy for cracked tooth disease. In this review, various medical imaging technologies for diagnosing cracked tooth are overviewed. In particular, the imaging modality, effect and the advantages of each diagnostic technique are discussed. What's more, AI-based crack detection and classification methods, especially the convolutional neural network (CNN)-based algorithms, including image classification (AlexNet), object detection (YOLO, Faster-RCNN), semantic segmentation (U-Net, Segnet) are comprehensively reviewed. Finally, the future perspectives and challenges in the diagnosis of the cracked tooth are lighted.
Collapse
Affiliation(s)
- Juncheng Guo
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Yuyan Wu
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Lizhi Chen
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Shangbin Long
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Daqi Chen
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Haibing Ouyang
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Chunliang Zhang
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China
| | - Yadong Tang
- School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, Guangzhou, 510006, China
| | - Wenlong Wang
- School of Mechanical and Electrical Engineering, Guangzhou University, Guangzhou, 510006, China.
| |
Collapse
|
3
|
Kashirtsev F, Tressel J, Simon JC, Fried D. High contrast imaging of dental fluorosis in the short wavelength infrared. JOURNAL OF BIOPHOTONICS 2021; 14:e202100145. [PMID: 34302430 PMCID: PMC9380435 DOI: 10.1002/jbio.202100145] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 07/20/2021] [Accepted: 07/22/2021] [Indexed: 06/13/2023]
Abstract
Dental fluorosis is an increasing problem due to over exposure to fluoride from the environment. Fluorosis causes hypomineralization of the enamel during tooth development and mild fluorosis is visible as faint white lines on the tooth surface while the most severe fluorosis can result in pitted surfaces. It is difficult to quantify the severity of mild to moderate fluorosis and assessments are limited to subjective visual examinations. Dental fluorosis appears with very high contrast at short wavelength infrared (SWIR) wavelengths beyond 1400 nm and we hypothesize that these wavelengths may be better suited for detecting mild fluorosis and for estimating the severity on tooth surfaces. In this study, the contrast of fluorosis of varying severity on extracted human permanent teeth was measured at SWIR wavelengths ranging from 1300 to 2150 nm using an extended range of InGaAs camera and broadband light sources. The contrast was also measured in the visible range and with quantitative light-induced fluorescence (QLF) for comparison. The depth of hypomineralization and the integrated reflectivity were also measured with cross-polarization optical coherence tomography. The contrast of hypomineralization is significantly higher (P < 0.05) at 1460 and 1950 nm wavelengths than for the visible, fluorescence or other SWIR wavelengths from 1300 to 2150 nm. The highest correlation of the contrast with the depth of hypomineralization measured with cross-polarization-optical coherence tomography (CP-OCT) was at 1950 nm. This SWIR in vitro imaging study exploring wavelengths beyond 1400 nm has shown that hypomineralization on tooth surfaces can be viewed with extremely high contrast at SWIR wavelengths from 1460 to 2000 nm and that SWIR imaging has great potential for monitoring hypomineralization on tooth surfaces. New clinical methods are needed for the measurement of fluorosis that are valid, reliable, and feasible for surveillance at the community level. In addition, methods are needed for the quantitative assessment of fluorosis in vivo.
Collapse
Affiliation(s)
| | | | | | - Daniel Fried
- Correspondence Daniel Fried, Department of Preventive and Restorative Dental Sciences, University of California, San Francisco, California 94143-0758.
| |
Collapse
|
4
|
Novel Approach to Tooth Chemistry. Quantification of the Dental-Enamel Junction. Int J Mol Sci 2021; 22:ijms22116003. [PMID: 34199407 PMCID: PMC8199634 DOI: 10.3390/ijms22116003] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 05/26/2021] [Accepted: 05/28/2021] [Indexed: 01/02/2023] Open
Abstract
The dentin-enamel junction (DEJ) is known for its special role in teeth. Several techniques were applied for the investigation of the DEJ in human sound molar teeth. The electron (EPMA) and proton (PIXE) microprobes gave consistent indications about the variability of elemental concentrations on this boundary. The locally increased and oscillating concentrations of Mg and Na were observed in the junction, in the layer adhering to the enamel and covering roughly half of the DEJ width. The chemical results were compared with the optical profiles of the junction. Our chemical and optical results were next compared with the micromechanical results (hardness, elastic modulus, friction coefficient) available in the world literature. A strong correlation of both result sets was proven, which testifies to the self-affinity of the junction structures for different locations and even for different kinds of teeth and techniques applied for studies. Energetic changes in tooth strictly connected with crystallographic transformations were calculated, and the minimum energetic status was discovered for DEJ zone. Modeling of both walls of the DEJ from optical data was demonstrated. Comparing the DEJ in human teeth with the same structure found in dinosaur, shark, and alligator teeth evidences the universality of dentin enamel junction in animal world. The paper makes a contribution to better understanding the joining of the different hard tissues.
Collapse
|
5
|
Demirkan I, Yaprak G, Ceylan C, Algul E, Tomruk CO, Bilen B, Unlu MB. Acoustic diagnosis of elastic properties of human tooth by 320 MHz scanning acoustic microscopy after radiotherapy treatment for head and neck cancer. Radiat Oncol 2020; 15:38. [PMID: 32066465 PMCID: PMC7027275 DOI: 10.1186/s13014-020-01486-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Accepted: 02/07/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND On the elastic profiles of human teeth after radiotherapy for head and neck cancers, generation of dental complications, which may bring several side effects preventing the quality of life, has not well clarified. Thus, we aimed to show the applicability of using 320 MHz Scanning Acoustic Microscopy (SAM) in the evaluation of the tooth damage acoustically at the micrometer level following radiation therapy, and also in the determination of the safe dose limits to impede severe dental damage. METHODS This prospective study was performed by SAM employed at 320 MHz by an azimuthal resolution of 4.7 μm resolving enamel and dentin. A total of 45 sound human third molar teeth collected between September 2018 and May 2019 were used for the acoustic impedance measurements pre- and post irradiation. Nine samples for each group (control, 2 Gy, 8 Gy, 20 Gy, 30 Gy and 60 Gy) were evaluated to acquire the acoustic images and perform a qualitative analysis. Scanning Electron Microscopy (SEM) images were obtained to establish a relationship between micromechanical and morphological characteristics of the teeth. Statistical analysis was conducted using the Student t-test succeded by Mann-Whitney U investigation (p < .05), while SEM images were assessed qualitatively. RESULTS The analysis included 45 sound teeth collected from men and women 18 to 50 years old. Post irradiation micromechanical variations of human teeth were significant only in the radiation groups of 30 Gy and 60 Gy compared to pre-irradiation group for enamel (7.24 ± 0.18 MRayl and 6.49 ± 028 MRayl; p < 0.05, respectively). Besides, the teeth subjected to radiation doses of 20, 30 and 60 Gy represented significantly lower acoustic impedance values relative to non-irradiated group for dentin (6.52 ± 0.43 MRayl, 5.71 ± 0.66 MRayl and 4.82 ± 0.53 MRayl p < 0.05), respectively. CONCLUSIONS These results are evidence for a safe acoustic examination device which may be a useful tool to visualize and follow the safe dose limits to impede severe dental damage through the radiation therapy treatment for head and neck cancers.
Collapse
Affiliation(s)
- Irem Demirkan
- Department of Physics, Bogazici University, Bebek, 34342, Istanbul, Turkey.
| | - Gokhan Yaprak
- Kartal Dr. Lutfi Kirdar Education and Research Hospital, Ministry of Health, 34890, Istanbul, Turkey
| | - Cemile Ceylan
- Department of Biomedical Engineering, Kocaeli University, 41380, Kocaeli, Turkey.,Istanbul Oncology Hospital, 34846, Istanbul, Turkey
| | - Emriye Algul
- Kartal Dr. Lutfi Kirdar Education and Research Hospital, Ministry of Health, 34890, Istanbul, Turkey
| | - Ceyda Ozcakir Tomruk
- Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, University of Yeditepe, 34728, İstanbul, Turkey
| | - Bukem Bilen
- Department of Physics, Bogazici University, Bebek, 34342, Istanbul, Turkey
| | - Mehmet Burcin Unlu
- Department of Physics, Bogazici University, Bebek, 34342, Istanbul, Turkey.,Global Station for Quantum Medical Science and Engineering, Global Institution for Collaborative Research and Education (GI-CoRE), Hokkaido University, Sapporo, 060-8648, Japan
| |
Collapse
|
6
|
Marotti J, Broeckmann J, Chuembou Pekam F, Praça L, Radermacher K, Wolfart S. Impression of Subgingival Dental Preparation Can Be Taken with Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:558-567. [PMID: 30454854 DOI: 10.1016/j.ultrasmedbio.2018.09.027] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 09/28/2018] [Accepted: 09/28/2018] [Indexed: 06/09/2023]
Abstract
Because of its ability to capture hard structures behind soft tissue, ultrasound-based micro-scanning may be a promising alternative for taking digital impressions of teeth, especially in the case of subgingival margin preparations. The aim of this study was to assess the accuracy of ultrasound impressions taken of subgingivally prepared teeth compared with digital optical impressions. Ten extracted human teeth (7 pre-molars, 3 molars) were prepared for crowns with chamfer finish line and then digitized using two different intra-oral scanners (Cara Trios, 3 Shape, Heraeus Kulzer, Hanau, Germany; and Lava COS; 3M ESPE, Seefeld, Germany) and one extra-oral scanner (Cares CS2, Straumann, Basel, Switzerland). Afterward, the preparation margin was covered with porcine gingiva (thickness ranged between 0.3 and 0.9 mm), and every sample was scanned with a high-frequency ultrasound scanner under experimental subgingival conditions. Optical scanning processes were performed without gingiva. The data sets were superimposed on each other for pairwise comparisons, and deviations between different scans were determined using a 3-D evaluation software (CloudCompare). Kruskal-Wallis and post hoc tests (Dunn-Bonferroni) were applied to detect significant differences at p ≤ 0.05. The ultrasound scanner was able to detect subgingival preparation margins. Mean deviations for all comparisons ranged from 12.34 to 46.38 µm. There were no statistically significant differences between superimpositions of intra-oral and extra-oral scans (Trios-Lava, Lava-CS2, Trios-CS2), whereas in comparisons between intra-/extra-oral scans and ultrasound scans, mean deviations were statistically significantly higher. There were no significant differences with respect to type of tooth (pre-molar and molar). However, gingiva thickness was significantly correlated with the quality of the ultrasound scan; thin layers had better image quality than thicker layers. Ultrasound was able to scan tooth preparation margins covered with gingiva, although with less accuracy than achieved by conventional optical scanners (non-covered margins). Gingiva thickness may play an important role in ultrasound scan accuracy.
Collapse
Affiliation(s)
- Juliana Marotti
- Centre for Implantology, Department of Prosthodontics and Biomaterials, Medical School RWTH Aachen University, Aachen, Germany.
| | - Judith Broeckmann
- Centre for Implantology, Department of Prosthodontics and Biomaterials, Medical School RWTH Aachen University, Aachen, Germany
| | | | - Luciano Praça
- Centre for Implantology, Department of Prosthodontics and Biomaterials, Medical School RWTH Aachen University, Aachen, Germany
| | - Klaus Radermacher
- Chair of Medical Engineering, RWTH Aachen University, Aachen, Germany
| | - Stefan Wolfart
- Centre for Implantology, Department of Prosthodontics and Biomaterials, Medical School RWTH Aachen University, Aachen, Germany
| |
Collapse
|
7
|
SAYED AHMEDM, LAMARCK RACHEL, CRUZ ELISA, CHAVES EROS, MUKDADI OSAMAM. QUANTITATIVE ASSESSMENT OF GINGIVAL INFLAMMATION USING HIGH-RESOLUTION ULTRASOUND EX-VIVO. J MECH MED BIOL 2018. [DOI: 10.1142/s0219519418500124] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This study investigates the feasibility of using high-resolution ultrasound imaging echogenicity to quantitatively diagnose gingival inflammation. Gingival samples were extracted from the study participants during gingivectomy procedures. Ultrasound mechanical scanning of the samples was immediately conducted ex-vivo to render cross-sectional images of high resolution, at different locations. Samples’ histological preparation and analysis was followed after performing ultrasound imaging. Histological sections were then matched with ultrasound images at different sections for each gingival sample. The matched image pairs were used to estimate two quantitative measures; relative inflammation area and ultrasound image echogenicity. These parameters were employed to judge the diagnostic potential of gingival ultrasound imaging. The results show that ultrasound images exhibited low intensity levels at the inflamed gingival regions, while healthy layers showed higher intensity levels. The relative area parameter implied a strong relationship between ultrasound and histological images. Ultrasound echogenicity was found to be statistically significant in differentiating between some inflammation degrees in the studied gingival samples. In summary, ultrasound imaging has the potential to be a noninvasive adjunct diagnostic tool for gingival inflammation, and may help assess the stage of the disease and ultimately limit periodontal disease occurrence; taking into consideration the limits of this study.
Collapse
Affiliation(s)
- AHMED M. SAYED
- Biomedical Engineering Department, Helwan University, Helwan, Cairo, Egypt
| | - RACHEL LAMARCK
- Piracicaba Dentistry College, University of Campina, Piracicaba, Brazil
| | - ELISA CRUZ
- Paulista Association for Medicine Development, Sao Paulo, Brazil
| | - EROS CHAVES
- College of Dentistry, University of Oklahoma, Oklahoma, USA
| | - OSAMA M. MUKDADI
- Mechanical and Aerospace Engineering Department, West Virginia University, Morgantown, West Virginia, USA
| |
Collapse
|
8
|
Sun K, Yuan L, Shen Z, Zhu Q. Nondestructive evaluation of demineralized enamel in a human incisor and molar using laser ultrasonics. APPLIED OPTICS 2018; 57:1231-1240. [PMID: 29469869 DOI: 10.1364/ao.57.001231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2017] [Accepted: 01/12/2018] [Indexed: 06/08/2023]
Abstract
This study aims to evaluate early caries in human teeth with different geometry structures by using the dispersion curves of a surface acoustic wave (SAW) generated by a pulsed laser. Through the finite element method, SAWs propagating on teeth models with different enamel thickness and curvature radius were simulated, and the influence of the geometry difference on the dispersion curves of SAWs was discussed. Laser ultrasonic experiments were performed on an extracted human incisor and molar with different demineralization conditions. The received dispersive surface wave signals were processed via the spectral analysis method to obtain the dispersion curves, and the difference of the dispersion spectra between the incisor and the molar was analyzed and discussed. The result demonstrates that the laser generating the SAW has the ability to evaluate the elastic properties of early caries with different geometry nondestructively.
Collapse
|
9
|
Kondrashova T, De Wan D, Briones MU, Kondrashov P. Integration of ultrasound imaging into pre-clinical dental education. EUROPEAN JOURNAL OF DENTAL EDUCATION : OFFICIAL JOURNAL OF THE ASSOCIATION FOR DENTAL EDUCATION IN EUROPE 2017; 21:228-234. [PMID: 27041147 DOI: 10.1111/eje.12205] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 03/15/2016] [Indexed: 06/05/2023]
Abstract
INTRODUCTION Patients have complex healthcare needs and typically require more than one healthcare discipline to address issues regarding their health. Interprofessional teams of healthcare professionals may be able to address these complex needs and improve patient outcomes by combining resources. To evaluate the feasibility of integrating ultrasound into a dental school curriculum to teach anatomy as part of an interprofessional education experience, the current study surveyed first-year dental students to determine their perceptions of the integration of ultrasound techniques into the curriculum. MATERIALS AND METHODS Ultrasound laboratory exercises were developed for first-year dental students as part of their anatomy course. The exercises were focused on head, neck and abdominal anatomy. To assess student perception of the integration of ultrasound into the dental curriculum, a survey was created specifically for the current study. RESULTS Between 2013 and 2015, two classes of first-year dental students participated in the ultrasound laboratory exercise and completed the survey (n = 83). Student survey responses suggested ultrasound was a valuable teaching tool because it allowed them to visualise anatomical structures using live imaging. They also agreed that the ultrasound laboratory exercises were an efficient learning tool, but the majority did not believe that they would use ultrasound regularly in their future practice. CONCLUSIONS Results of the current study suggested first-year dental students were satisfied with the integration of ultrasound techniques into the dental curriculum. Survey results indicated that the students enjoyed the ultrasound laboratory exercise and felt ultrasound was an effective learning tool.
Collapse
Affiliation(s)
- T Kondrashova
- Department of Family Medicine, Preventive Medicine and Community Health, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, USA
| | - D De Wan
- Missouri School of Dentistry & Oral Health, A.T. Still University, Kirksville, MO, USA
| | - M U Briones
- Academic Affairs, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, USA
| | - P Kondrashov
- Anatomy Department, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, USA
| |
Collapse
|
10
|
Du J, Mao XL, Ye PF, Huang QH. Three-Dimensional Reconstruction and Visualization of Human Enamel Ex Vivo Using High-Frequency Ultrasound. J Med Biol Eng 2017. [DOI: 10.1007/s40846-016-0213-1] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
11
|
High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System. Ann Biomed Eng 2016; 44:2874-2886. [DOI: 10.1007/s10439-016-1634-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Accepted: 04/29/2016] [Indexed: 10/21/2022]
|
12
|
Chan HL, Wang HL, Fowlkes JB, Giannobile WV, Kripfgans OD. Non-ionizing real-time ultrasonography in implant and oral surgery: A feasibility study. Clin Oral Implants Res 2016; 28:341-347. [PMID: 26992276 DOI: 10.1111/clr.12805] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/24/2016] [Indexed: 01/17/2023]
Abstract
PURPOSE Ultrasound imaging has potential to complement radiographic imaging modalities in implant and oral surgery given that it is non-ionizing and provides instantaneous images of anatomical structures. For application in oral and dental imaging, its qualities are dependent on its ability to accurately capture these complex structures. Therefore, the aim of this feasibility study was to investigate ultrasound to image soft tissue, hard tissue surface topography and specific vital structures. MATERIAL AND METHODS A clinical ultrasound scanner, paired with two 14-MHz transducers of different sizes (one for extraoral and the other for intraoral scans), was used to scan the following structures on a fresh cadaver: (i) the facial bone surface and soft tissue of maxillary anterior teeth, (ii) the greater palatine foramen; (iii) the mental foramen and (iv) the lingual nerve. Multiple measurements relevant to these structures were made on the ultrasound images and compared to those on cone-beam computed tomography (CBCT) scans and/or direct measurements. RESULTS Ultrasound imaging could delineate hard tissue surfaces, including enamel, root dentin and bone as well as soft tissue with high resolution (110 μm wavelength). The greater palatine foramen, mental foramen and lingual nerve were clearly shown in ultrasound images. Merging ultrasound and CBCT images demonstrated overall spatial accuracy of ultrasound images, which was corroborated by data gathered from direct measurements. CONCLUSION For the first time, this study provides proof-of-concept evidence that ultrasound can be a real-time and non-invasive alternative for the evaluation of oral and dental anatomical structures relevant for implant and oral surgery.
Collapse
Affiliation(s)
- Hsun-Liang Chan
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Hom-Lay Wang
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA
| | - Jeffery Brian Fowlkes
- Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, USA.,Department of Biomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, USA
| | - William V Giannobile
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, MI, USA.,Department of Biomedical Engineering, College of Engineering, University of Michigan, Ann Arbor, MI, USA
| | - Oliver D Kripfgans
- Department of Radiology, University of Michigan Medical School, Ann Arbor, MI, USA
| |
Collapse
|
13
|
Nguyen KCT, Le LH, Kaipatur NR, Major PW. Imaging the Cemento-Enamel Junction Using a 20-MHz Ultrasonic Transducer. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:333-8. [PMID: 26546266 DOI: 10.1016/j.ultrasmedbio.2015.09.012] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Revised: 09/08/2015] [Accepted: 09/11/2015] [Indexed: 05/22/2023]
Abstract
The cemento-enamel junction (CEJ), which is the intersection between enamel and cementum, is an important landmark in the diagnosis of periodontal disease. Pulse-echo ultrasound was used to image the CEJs of six porcine lower central incisors with a single 20-MHz transducer. A notch was longitudinally created on the enamel as a stable marker, from which the CEJ was measured. Data were acquired along the tooth's axis at 0.4-mm intervals. Time-distance data were bandpass-filtered to enhance signal-to-noise ratio and record density was increased fourfold to 0.1-mm spacing by a frequency-distance interpolation scheme. Reflections from the CEJ were unambiguously identified along with those from enamel, dentin and cementum. The notch-CEJ distances measured by the ultrasound and micro-computed tomography methods correlated strongly (r = 0.996, p < 0.05) and were in good agreement with the 95% lines of agreement between -0.49 and 0.17 mm, as statistically determined by Bland-Altman analysis. The results indicate the potential of ultrasound to be a reliable and non-ionizing technique to image the CEJ.
Collapse
Affiliation(s)
- Kim-Cuong T Nguyen
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada; Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada.
| | | | - Paul W Major
- School of Dentistry, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
14
|
Hughes DA, Sampathkumar A, Longbottom C, Kirk KJ. Imaging and detection of early stage dental caries with an all-optical photoacoustic microscope. ACTA ACUST UNITED AC 2015. [DOI: 10.1088/1742-6596/581/1/012002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
15
|
Sun K, Yuan L, Shen Z, Xu Z, Zhu Q, Ni X, Lu J. Scanning laser-line source technique for nondestructive evaluation of cracks in human teeth. APPLIED OPTICS 2014; 53:2366-2374. [PMID: 24787406 DOI: 10.1364/ao.53.002366] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2013] [Accepted: 02/25/2014] [Indexed: 06/03/2023]
Abstract
This paper describes the first application of a remote nondestructive laser ultrasonic (LU) system for clinical diagnosis of cracks in human teeth, to our knowledge. It performs non-contact cracks detection on small-dimension teeth samples. Two extracted teeth with different types of cracks (cracked tooth and craze lines), which have different crack depths, are used as experimental samples. A series of ultrasonic waves were generated by a scanning laser-line source technique and detected with a laser-Doppler vibrometer on the two samples. The B-scan images and peak-to-peak amplitude variation curves of surface acoustic waves were obtained for evaluating the cracks' position and depth. The simulation results calculated by finite element method were combined with the experimental results for accurately measuring the depth of crack. The results demonstrate that this LU system has been successfully applied on crack evaluation of human teeth. And as a remote, nondestructive technique, it has great potential for early in vivo diagnosis of cracked tooth and even the future clinical dental tests.
Collapse
|
16
|
Marotti J, Heger S, Tinschert J, Tortamano P, Chuembou F, Radermacher K, Wolfart S. Recent advances of ultrasound imaging in dentistry--a review of the literature. Oral Surg Oral Med Oral Pathol Oral Radiol 2014; 115:819-32. [PMID: 23706922 DOI: 10.1016/j.oooo.2013.03.012] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2012] [Revised: 12/28/2012] [Accepted: 03/16/2013] [Indexed: 02/07/2023]
Abstract
Ultrasonography as an imaging modality in dentistry has been extensively explored in recent years due to several advantages that diagnostic ultrasound provides. It is a non-invasive, inexpensive, painless method and unlike X-ray, it does not cause harmful ionizing radiation. Ultrasound has a promising future as a diagnostic imaging tool in all specialties in dentistry, for both hard and soft tissue detection. The aim of this review is to provide the scientific community and clinicians with an overview of the most recent advances of ultrasound imaging in dentistry. The use of ultrasound is described and discussed in the fields of dental scanning, caries detection, dental fractures, soft tissue and periapical lesions, maxillofacial fractures, periodontal bony defects, gingival and muscle thickness, temporomandibular disorders, and implant dentistry.
Collapse
Affiliation(s)
- Juliana Marotti
- Department of Prosthodontics, School of Dentistry, University of São Paulo, Av. Prof. Lineu Prestes 2227, 05508-000 São Paulo-SP.
| | | | | | | | | | | | | |
Collapse
|
17
|
Sun K, Yuan L, Shen Z, Zhu Q, Lu J, Ni X. Experimental and numerical studies for nondestructive evaluation of human enamel using laser ultrasonic technique. APPLIED OPTICS 2013; 52:6896-6905. [PMID: 24085203 DOI: 10.1364/ao.52.006896] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2013] [Accepted: 08/25/2013] [Indexed: 06/02/2023]
Abstract
In this paper, a nondestructive laser ultrasonic technique is used to generate and detect broadband surface acoustic waves (SAWs) on human teeth with different demineralization treatment. A scanning laser line-source technique is used to generate a series of SAW signals for obtaining the dispersion spectrum through a two-dimensional fast Fourier translation method. The experimental dispersion curves of SAWs are studied for evaluating the elastic properties of the sound tooth and carious tooth. The propagation and dispersion of SAWs in human teeth are also been studied using the finite element method. Results from numerical simulation and experiment are compared and discussed, and the elastic properties of teeth with different conditions are evaluated by combining the simulation and experimental results.
Collapse
|
18
|
Shelke A, Blume M, Mularczyk M, Landes C, Sader R, Bereiter-Hahn J. Visualization of localized elastic properties in human tooth and jawbone as revealed by scanning acoustic microscopy. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:853-859. [PMID: 23465135 DOI: 10.1016/j.ultrasmedbio.2012.11.028] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 11/22/2012] [Accepted: 11/26/2012] [Indexed: 06/01/2023]
Abstract
The elastic properties of human canine and supporting alveolar bone are measured by the distribution of localized speed of sound using scanning acoustic microscopy. Methods for the dynamic, non-destructive diagnostics of dental hard tissues can have a key role in the early detection of demineralization processes and carious lesions, and they are supposed to open the possibility of early dental restorations. The localized distribution of the ultrasound velocity in canine tooth and alveolar bone was obtained using scanning acoustic microscopy with a 5- and 30-MHz transducer. An acoustic material signature curve signifies the interference of the waves and quantitatively maps the localized speed of sound in alveolar bone and the canine tooth. Seven samples, consisting of alveolar jawbone and tooth sliced along the coronally apical axis, were investigated. The average speed of sound was determined along three independent cross sections at enamel, dentin and cortical bone. The average speed of sound in enamel, bone and dentin was SD 3460 ± 193 m/s, 3232 ± 113 m/s and 2928 ± 106 m/s. The distribution of sound wave propagation reveals a decrease in sound speed from the peripheral parts within the enamel and dentin layers toward the proximal zones. These results prove the possibility of linking the elastic properties to different areas within the osseous and dental hard tissues and visualize them in an extremely high local resolution. The results serve as a basis for further study and substantiate the enormous potential of ultrasound based analysis in the field of dento-alveolar diagnosis.
Collapse
Affiliation(s)
- Amit Shelke
- Institute for Cell Biology and Neurosciences, Kinematic Cell Research Group Goethe University, Frankfurt, Germany.
| | | | | | | | | | | |
Collapse
|
19
|
Deepak BS, Subash TS, Narmatha VJ, Anamika T, Snehil TK, Nandini DB. Imaging techniques in endodontics: an overview. J Clin Imaging Sci 2012; 2:13. [PMID: 22530184 PMCID: PMC3328979 DOI: 10.4103/2156-7514.94227] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2012] [Accepted: 02/17/2012] [Indexed: 02/06/2023] Open
Abstract
This review provides an overview of the relevance of imaging techniques such as, computed tomography, cone beam computed tomography, and ultrasound, to endodontic practice. Many limitations of the conventional radiographic techniques have been overcome by the newer methods. Advantages and disadvantages of various imaging techniques in endodontic practice are also discussed.
Collapse
Affiliation(s)
- B S Deepak
- Department of Conservative Dentistry and Endodontics, Bapuji Dental College, Davangere, Karnataka, India
| | | | | | | | | | | |
Collapse
|
20
|
Harput S, Evans T, Bubb N, Freear S. Diagnostic ultrasound tooth imaging using fractional Fourier transform. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:2096-2106. [PMID: 21989873 DOI: 10.1109/tuffc.2011.2059] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
An ultrasound contact imaging method is proposed to measure the enamel thickness in the human tooth. A delay-line transducer with a working frequency of 15 MHz is chosen to achieve a minimum resolvable distance of 400 μm in human enamel. To confirm the contact between the tooth and the transducer, a verification technique based on the phase shift upon reflection is used. Because of the high attenuation in human teeth, linear frequency-modulated chirp excitation and pulse compression are exploited to increase the penetration depth and improve the SNR. Preliminary measurements show that the enamel-dentin boundary creates numerous internal reflections, which cause the applied chirp signals to interfere arbitrarily. In this work, the fractional Fourier transform (FrFT) is employed for the first time in dental imaging to separate chirp signals overlapping in both time and frequency domains. The overlapped chirps are compressed using the FrFT and matched filter techniques. Micro-computed tomography is used for validation of the ultrasound measurements for both techniques. For a human molar, the thickness of the enamel layer is measured with an average error of 5.5% after compressing with the FrFT and 13.4% after compressing with the matched filter based on the average speed of sound in human teeth.
Collapse
Affiliation(s)
- Sevan Harput
- Ultrasound Group, School of Electronic and Electrical Engineering, University of Leeds, Leeds, UK.
| | | | | | | |
Collapse
|
21
|
Hughes DA, Girkin JM, Poland S, Longbottom C, Button TW, Elgoyhen J, Hughes H, Meggs C, Cochran S. Investigation of dental samples using a 35MHz focussed ultrasound piezocomposite transducer. ULTRASONICS 2009; 49:212-218. [PMID: 18930302 DOI: 10.1016/j.ultras.2008.08.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2008] [Revised: 08/13/2008] [Accepted: 08/16/2008] [Indexed: 05/26/2023]
Abstract
Dental erosion and decay are increasingly prevalent but as yet there is no quantitative monitoring tool. Such a tool would allow earlier diagnosis and treatment and ultimately the prevention of more serious disease and pain. Despite ultrasound having been demonstrated as a method of probing the internal structures of teeth more than 40 years ago, development of a clinical tool has been slow. The aim of the study reported here was to investigate the use of a novel high frequency ultrasound transducer and validate it using a known dental technique. A tooth extracted for clinical reasons was sectioned to provide a sample that contained an enamel and dentine layer such that the enamel-dentine junction (EDJ) was of a varying depth. The sample was then submerged in water and a B-scan recorded using a custom-designed piezocomposite ultrasound transducer with a centre frequency of 35 MHz and a -6 dB bandwidth of 24 MHz. The transducer has an axial resolution of 180 microm and a spatial resolution of 110 microm, a significant advance on previous work using lower frequencies. The depth of the EDJ was measured from the resulting data set and compared to measurements from the sequential grinding and imaging (SGI) method. The B-scan showed that the EDJ was of varying depth. Subsequently, the EDJ measurements were found to have a correlation of 0.89 (p<0.01) against the SGI measurements. The results indicate that high frequency ultrasound is capable of measuring enamel thickness to an accuracy of within 10% of the total enamel thickness, whereas currently there is no clinical tool available to measure enamel thickness.
Collapse
Affiliation(s)
- D A Hughes
- Institute of Photonics, SUPA, University of Strathclyde, Glasgow, Scotland, UK.
| | | | | | | | | | | | | | | | | |
Collapse
|
22
|
Hua J, Chen SK, Kim Y. Refining enamel thickness measurements from B-mode ultrasound images. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2009:440-443. [PMID: 19964934 DOI: 10.1109/iembs.2009.5334783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Dental erosion has been growing increasingly prevalent with the rise in consumption of heavy starches, sugars, coffee, and acidic beverages. In addition, various disorders, such as Gastroenterological Reflux Disease (GERD), have symptoms of rapid rates of tooth erosion. The measurement of enamel thickness would be important for dentists to assess the progression of enamel loss from all forms of erosion, attrition, and abrasion. Characterizing enamel loss is currently done with various subjective indexes that can be interpreted in different ways by different dentists. Ultrasound has been utilized since the 1960s to determine internal tooth structure, but with mixed results. Via image processing and enhancement, we were able to refine B-mode dental ultrasound images for more accurate enamel thickness measurements. The mean difference between the measured thickness of the occlusal enamel from ultrasound images and corresponding gold standard CT images improved from 0.55 mm to 0.32 mm with image processing (p = 0.033). The difference also improved from 0.62 to 0.53 mm at the buccal/lingual enamel surfaces, but not significantly (p = 0.38).
Collapse
Affiliation(s)
- Jeremy Hua
- Department of Bioengineering, University of Washington, Seattle, WA 98195 USA. jhua27@ u.washington.edu
| | | | | |
Collapse
|
23
|
Raum K. Microelastic imaging of bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1417-1431. [PMID: 18986931 DOI: 10.1109/tuffc.2008.817] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Several high-frequency ultrasound techniques have been developed during the last decade with the intention of assessing elastic properties of bone at the tissue level. The basic measurement principles can be divided into: 1) measurement of the compressional wave velocity in thin tissue sections; 2) measurement of surface acoustic wave velocities in thick sections; and 3) derivation of the acoustic impedance from the confocal reflection amplitude in thick sections. In this paper, the 3 principles are described with example measurements given in the frequency range from 50 MHz to 1.2 GHz. The measurements were made with 2 microscopes operating in the pulse-echo mode, either with frequencies up to 200 MHz and time-resolved detection or between 100 MHz and 2 GHz and amplitude detection. The methods are compared and their application potentials and limitations are discussed with respect to the hierarchical structure of cortical bone. Mapping of the confocal reflection amplitude has superior capabilities for deriving quantitative elastic and structural parameters in the heterogeneous bone material. Even at low frequencies (50 MHz), the mineralized tissue matrix can be separated from the larger pores (Haversian canals), and the elastic coefficient in the probing direction can be measured in 2 dimensions. Depending on the type of sample surface preparation (flat or cylindrically shaped), local distribution of a single elastic coefficient or the average transverse isotropic stiffness tensor can be derived. With frequencies in the GHz range, the lamellar bone structure can be analyzed. However, at one GHz, the acoustic wavelength is still one order of magnitude larger than the individual mineralized collagen fibrils. Although the thickness of a lamellar unit can easily be assessed from the acoustic image, the derivation of the anisotropic elastic properties of the mineralized collagen fibrils as well as the detailed structure of a lamella can only be accomplished with further model assumptions.
Collapse
Affiliation(s)
- K Raum
- Dept. of Orthopedics, Martin Luther Univ. of Halle-Wittenberg, Halle, Germany.
| |
Collapse
|
24
|
Singh RS, Culjat MO, Grundfest WS, Brown ER, White SN. Tissue mimicking materials for dental ultrasound. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2008; 123:EL39-44. [PMID: 18396919 PMCID: PMC2677313 DOI: 10.1121/1.2884083] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
While acoustic tissue mimicking materials have been explored for a variety of soft and hard biological tissues, no dental hard tissue mimicking materials have been characterized. Tooth phantoms are necessary to better understand acoustic phenomenology within the tooth environment and to accelerate the advancement of dental ultrasound imaging systems. In this study, soda lime glass and dental composite were explored as surrogates for human enamel and dentin, respectively, in terms of compressional velocity, attenuation, and acoustic impedance. The results suggest that a tooth phantom consisting of glass and composite can effectively mimic the acoustic behavior of a natural human tooth.
Collapse
|
25
|
|
26
|
Ghorayeb SR, Bertoncini CA, Hinders MK. Ultrasonography in dentistry. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1256-1266. [PMID: 18599413 DOI: 10.1109/tuffc.2008.788] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
This paper reviews diagnostic applications of ultrasound to dentistry, or dental ultrasonography, beginning with pioneering work of the 1960s up through present lines of research. Clinical, in vivo applications that are of direct interest to dental practice are reviewed here, including measurements of enamel thickness and periodontal pocket depth. In vitro research that involves destructive tooth preparation or procedures, such as sound speed measurements or scanning acoustic microscopy, also are included. Although dental ultrasonography has been studied for over 40 years, most methods are not quite ready for routine clinical use, and there remains much opportunity for diagnostic ultrasonography to significantly impact the practice of dentistry.
Collapse
Affiliation(s)
- Sleiman R Ghorayeb
- Hofstra University, Department of Biomedical Sciences, Hempstead, NY, USA.
| | | | | |
Collapse
|
27
|
Mahmoud A, Cortes D, Abaza A, Ammar H, Hazey M, Ngan P, Crout R, Mukdadi O. Noninvasive assessment of human jawbone using ultrasonic guided waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2008; 55:1316-1327. [PMID: 18599419 DOI: 10.1109/tuffc.2008.794] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The problem of detecting defects in jawbones is an important problem. Existing methods based on Xrays are invasive and constrain the achievable image quality. They also may carry known risks of cancer generation or may be limited in accurate diagnosis scope. This work is motivated by the lack of current imaging modalities to accurately predict the mechanical properties and defects in jawbone. Ultrasonic guided waves are sensitive to changes in microstructural properties and thus have been widely used for noninvasive material characterization. Using these waves may provide means for early diagnosis of marrow ischemic disorders via detecting focal osteoporotic marrow defect, chronic nonsuppurative osteomyelitis, and cavitations in the mandible (jawbone). Guided waves propagating along the mandibles may exhibit dispersion behavior that depends on material properties, geometry, and embedded cavities. In this work, we present the first study in the theoretical and experimental analysis of guided wave propagation in jawbone. Semianalytical, finite-element (SAFE) method is used to analyze dispersion behavior of guided waves propagating in human mandibles. The geometry of the cross section is obtained by segmenting the computed tomography (CT) images of the jawbone. The cross section of the mandible is divided in two regions representing the cortical and trabecular bones. Each region is modeled as a linear Hookean material. The material properties for both regions are adopted from the literature. The experimental setup for the guided waves experiment is described. The results from both numerical analysis and guided waves experiment exhibit variations in the group velocity of the first arrival signal and in the dispersion behavior of healthy and defected mandibles. These results shall provide a means to noninvasively characterize the jawbone and accurately assess the bone mechanical properties. Our study is not aimed at characterizing the bone density in human mandibles. Rather, it is aimed to assess bone mechanical properties and defects that cannot be diagnosed by X-ray or other imaging modalities. This work may pave the way to the development of inexpensive noninvasive devices to detect small defects in human mandibles.
Collapse
|
28
|
Shemesh H, Goertz DE, van der Sluis LWM, de Jong N, Wu MK, Wesselink PR. High frequency ultrasound imaging of a single-species biofilm. J Dent 2007; 35:673-8. [PMID: 17604896 DOI: 10.1016/j.jdent.2007.05.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2007] [Revised: 05/21/2007] [Accepted: 05/22/2007] [Indexed: 10/23/2022] Open
Abstract
OBJECTIVE This study evaluated the feasibility of a high frequency ultrasound scan to examine the 3D morphology of Streptococcus mutans biofilms grown in vitro. METHODS Six 2-day S. mutans biofilms and six 7-day biofilms were grown on tissue culture membranes and on bovine dentine discs. A sterile growth medium on the membrane and disc were used as controls. Surfaces were rinsed and then immersed in sterile saline. High-frequency ultrasound imaging system was used to scan these surfaces at 55MHz, and a computer program calculated the average thickness of the biofilm layer from the 3D images. RESULTS 3D pictures of the biofilm layers were obtained. Different cross-sections and plains are easily demonstrated. The average thickness of the 7-day biofilm was significantly bigger than the 2-day on both the membranes and dentinal discs. No structures were observed on the sterile membrane or disc. CONCLUSION Three-dimensional structural imaging in situ is possible without damaging the biofilm layer in a quick and easy manner and can therefore be used to evaluate biofilms longitudinally as a function of time.
Collapse
Affiliation(s)
- H Shemesh
- Department of Cariology Endodontology Pedodontology, Academic Centre for Dentistry Amsterdam (ACTA), Louwesweg 1, 1066 EA Amsterdam, The Netherlands.
| | | | | | | | | | | |
Collapse
|
29
|
The laterally varying ultrasonic velocity in the dentin of human teeth. J Biomech 2006; 39:2388-96. [DOI: 10.1016/j.jbiomech.2005.08.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2005] [Accepted: 08/04/2005] [Indexed: 11/23/2022]
|
30
|
Evaluation of gallium-indium alloy as an acoustic couplant for high-impedance, high-frequency applications. ACTA ACUST UNITED AC 2005. [DOI: 10.1121/1.1903025] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
31
|
Culjat MO, Singh RS, Brown ER, Neurgaonkar RR, Yoon DC, White SN. Ultrasound crack detection in a simulated human tooth. Dentomaxillofac Radiol 2005; 34:80-5. [PMID: 15829689 DOI: 10.1259/dmfr/12901010] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE Currently, diagnosis of cracked teeth generally depends upon the overall clinical assessment, or on exclusion of other clinical possibilities, not primarily on the direct identification of cracks themselves. Owing to its short wavelength in hard tissues and associated high resolution, ultrasound has the potential to allow detection of cracks within tooth structure. However, ultrasound detection of dental cracks has not previously been achieved. The purpose was to determine if an ultrasound imaging system was capable of imaging cracks in simulated tooth structure. METHODS A complete ultrasound system including a novel transducer made of PLZT-98, a novel gallium-indium alloy coupling agent, and customized electronic and digital signal processing (DSP) algorithms was developed for the specific application of optimizing crack detection within teeth. A simulated tooth with a known and uniform internal structure and acoustic properties similar to those of natural enamel and dentin was designed to model a human tooth with a crack located in dentin deep to the dentino-enamel junction (DEJ). The distance between the DEJ and a crack of the simulated tooth were calculated. RESULTS The system unequivocally distinguished between areas with and without a simulated crack. CONCLUSION A unique ultrasound dental crack detection system using a novel transducer; a novel coupling agent; and customized electronic and digital signal processing (DSP) algorithms has been validated in a simulated tooth.
Collapse
Affiliation(s)
- M O Culjat
- UCLA Henry Samueli School of Engineering and Applied Science, Los Angeles, California 90095, USA
| | | | | | | | | | | |
Collapse
|