1
|
Devine TM, Alter KE, Damiano DL, Bulea TC. A randomized cross-over study protocol to evaluate long-term gait training with a pediatric robotic exoskeleton outside the clinical setting in children with movement disorders. PLoS One 2024; 19:e0304087. [PMID: 38976710 PMCID: PMC11230531 DOI: 10.1371/journal.pone.0304087] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 05/02/2024] [Indexed: 07/10/2024] Open
Abstract
Individuals with neuromuscular disorders display a combination of motor control deficits and lower limb weakness contributing to knee extension deficiency characterized by exaggerated stance phase knee flexion. There is a lack of evidence for long-term improvement of knee extension deficiency with currently available clinical treatment programs. Our previous work testing a wearable robotic exoskeleton with precisely timed assistive torque applied at the knee showed immediate increases in knee extension during walking for children with cerebral palsy, which continued to improve over an acute practice period. When we applied interleaved assistance and resistance to knee extension, we observed improvements in knee extension and increased muscle activation indicating the potential for muscle strengthening when used over time. There is a need for additional, high-quality trials to assess the impact of dosage, intensity and volume of training necessary to see persistent improvement in lower limb function for these patient populations. This randomized crossover study (ClinicalTrials.gov: NCT05726591) was designed to determine whether 12 weeks of overground gait training with a robotic exoskeleton outside of the clinical setting, following an initial in clinic accommodation period, has a beneficial effect on walking ability, muscle activity and overall motor function. Participants will be randomized to either complete the exoskeleton intervention or continue their standard therapy for 12 weeks first, followed by a crossover to the other study component. The primary outcome measure is change in peak knee extension angle during walking; secondary outcome measures include gait speed, strength, and validated clinical scales of motor function and mobility. Assessments will be completed before and after the intervention and at 6 weeks post-intervention, and safety and compliance will be monitored throughout. We hypothesize that the 12-week exoskeleton intervention outside the clinical setting will show greater improvements in study outcome measures than the standard therapy.
Collapse
Affiliation(s)
- Taylor M. Devine
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, Maryland, United States of America
| | - Katharine E. Alter
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, Maryland, United States of America
| | - Diane L. Damiano
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, Maryland, United States of America
| | - Thomas C. Bulea
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, Maryland, United States of America
| |
Collapse
|
2
|
Guo C, Cun Y, Xia B, Chen S, Zhang C, Chen Y, Shan E, Zhang P, Tai X. An analysis of stimulation methods used in rehabilitation equipment for children with cerebral palsy. Front Neurol 2024; 15:1371332. [PMID: 38966084 PMCID: PMC11223519 DOI: 10.3389/fneur.2024.1371332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 05/31/2024] [Indexed: 07/06/2024] Open
Abstract
Objective This paper summarizes the research progress into stimulation methods used in rehabilitation equipment for pediatric cerebral palsy (CP) for the past 20 years from 2003 to 2023. We also provide ideas for innovative research and development of artificial intelligence-based rehabilitation equipment. Methods Through a certain search strategy, Keywords are searched in the China National Knowledge Network Database (CNKI), the Wanfang Database knowledge service platform, the Chongqing VIP information service, PubMed, Web of Science, Cochrane, ScienceDirect, Medline, Embase, and IEEE database. A total of 3,049 relevant articles were retrieved, and 49 articles were included that mentioned research and development of rehabilitation equipment. We excluded articles that were not specific to children with CP, were duplicated or irrelevant literature, were missing data, the full article was not available, the article did not describe the method of stimulation used with the rehabilitation equipment on children with CP, were not Chinese and English, and were the types of reviews and commentaries. Results Physical stimulation is the main stimulation method of rehabilitation equipment for children with CP. Force stimulation is the main mode of physical stimulation, and there are 17 articles that have verified the clinical efficacy of force stimulation-based equipment. Conclusion Research on the stimulation mode of pediatric cerebral palsy rehabilitation equipment is likely to focus on simulating the force of the Chinese medicine called "tuina manipulation." When this method is combined with artificial intelligence and personalized direction we believe this will lay the foundation for future development of a novel therapy for children with CP.
Collapse
Affiliation(s)
- Cunxiao Guo
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Yongdan Cun
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
- Yunnan College of Business Management, Kunming, China
| | - Bo Xia
- Master of Science in Computer Science, Sofia University, Palo Alto, CA, United States
| | - Suyu Chen
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Can Zhang
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Yiping Chen
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Exian Shan
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Pengyue Zhang
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| | - Xiantao Tai
- Yunnan Key Laboratory of Integrated Traditional Chinese and Western Medicine for Chronic Disease in Prevention and Treatment, Key Laboratory of Acupuncture and Massage for Treatment of Encephalopathy, College of Acupuncture and Tuina Rehabilitation, Yunnan University of Chinese Medicine, Kunming, Yunnan, China
| |
Collapse
|
3
|
Dierwechter B, Kolakowsky-Hayner SA. Journey to 1 Million Steps: A Retrospective Case Series Analyzing the Implementation of Robotic-Assisted Gait Training Into an Outpatient Pediatric Clinic. Pediatr Phys Ther 2024; 36:285-293. [PMID: 38349640 DOI: 10.1097/pep.0000000000001097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/16/2024]
Abstract
PURPOSE To describe the implementation of an exoskeleton program in a rehabilitation setting using a Design Thinking framework. METHODS This is a retrospective case series of 3 randomly selected children who participated in skilled physical therapy using a pediatric exoskeleton that occurred on our journey to walking 1 000 000 steps in the exoskeleton devices. Participants ranged in age from 3 to 5 years, and all had neurologic disorders. RESULTS All participants improved toward achieving their therapy goals, tolerated the exoskeleton well, and had an increased number of steps taken over time. CONCLUSION The implementation of new technology into pediatric care and an established outpatient therapy clinic is described. The Design Thinking process applies to health care professionals and improves clinical care. Exoskeletons are effective tools for use in pediatric physical therapy.
Collapse
Affiliation(s)
- Brittany Dierwechter
- Outpatient Physical Therapy Department (Dr Dierwechter) and Research and Clinical Outcomes Department (Dr Kolakowsky-Hayner), Good Shepherd Rehabilitation Network, Allentown, Pennsylvania
| | | |
Collapse
|
4
|
Mansilla Navarro P, Copaci D, Blanco Rojas D. Design and Control of a Soft Knee Exoskeleton for Pediatric Patients at Early Stages of the Walking Learning Process. Bioengineering (Basel) 2024; 11:188. [PMID: 38391674 PMCID: PMC10886139 DOI: 10.3390/bioengineering11020188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Revised: 02/12/2024] [Accepted: 02/14/2024] [Indexed: 02/24/2024] Open
Abstract
Pediatric patients can suffer from different motor disorders that limit their neurological and motor development and hinder their independence. If treated at the very early stages of development, those limitations can be palliated or even removed. However, manual interventions are not completely effective due to the restrictions in terms of time, force, or tracking experienced by the physiotherapists. The knee flexo-extension is crucial for walking and often affected by disorders such as spasticity or lack of force in the posterior chain. This article focuses on the development of a knee exosuit to follow angular trajectories mimicking the maximum and minimum peaks present in the knee flexo-extension profiles of healthy individuals during walking. The proposed exosuit is based on shape memory alloy actuators along with four inertial sensors that close the control loop. The whole device is controlled through a two-level controller and has an hybrid rigid-flexible design to overcome the different issues present in the literature. The device was proven to be feasible for this type of application, with replicable and consistent behavior, reducing the price and weight of existing exosuits and enhancing patient comfort.
Collapse
Affiliation(s)
- Paloma Mansilla Navarro
- Department of Systems Engineering and Automation, Universidad Carlos III de Madrid, 28015 Leganes, Spain
| | - Dorin Copaci
- Department of Systems Engineering and Automation, Universidad Carlos III de Madrid, 28015 Leganes, Spain
| | - Dolores Blanco Rojas
- Department of Systems Engineering and Automation, Universidad Carlos III de Madrid, 28015 Leganes, Spain
| |
Collapse
|
5
|
Kim J, Porciuncula F, Yang HD, Wendel N, Baker T, Chin A, Ellis TD, Walsh CJ. Soft robotic apparel to avert freezing of gait in Parkinson's disease. Nat Med 2024; 30:177-185. [PMID: 38182783 DOI: 10.1038/s41591-023-02731-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 11/21/2023] [Indexed: 01/07/2024]
Abstract
Freezing of gait (FoG) is a profoundly disruptive gait disturbance in Parkinson's disease, causing unintended stops while walking. Therapies for FoG reveal modest and transient effects, resulting in a lack of effective treatments. Here we show proof of concept that FoG can be averted using soft robotic apparel that augments hip flexion. The wearable garment uses cable-driven actuators and sensors, generating assistive moments in concert with biological muscles. In this n-of-1 trial with five repeated measurements spanning 6 months, a 73-year-old male with Parkinson's disease and substantial FoG demonstrated a robust response to robotic apparel. With assistance, FoG was instantaneously eliminated during indoor walking (0% versus 39 ± 16% time spent freezing when unassisted), accompanied by 49 ± 11 m (+55%) farther walking compared to unassisted walking, faster speeds (+0.18 m s-1) and improved gait quality (-25% in gait variability). FoG-targeting effects were repeatable across multiple days, provoking conditions and environment contexts, demonstrating potential for community use. This study demonstrated that FoG was averted using soft robotic apparel in an individual with Parkinson's disease, serving as an impetus for technological advancements in response to this serious yet unmet need.
Collapse
Affiliation(s)
- Jinsoo Kim
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA
| | - Franchino Porciuncula
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA
- Department of Physical Therapy, Boston University, Boston, MA, USA
| | - Hee Doo Yang
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA
| | - Nicholas Wendel
- Department of Physical Therapy, Boston University, Boston, MA, USA
| | - Teresa Baker
- Department of Physical Therapy, Boston University, Boston, MA, USA
| | - Andrew Chin
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA
| | - Terry D Ellis
- Department of Physical Therapy, Boston University, Boston, MA, USA.
| | - Conor J Walsh
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA.
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA.
| |
Collapse
|
6
|
Pandey RA, Johari AN, Shetty T. Crouch Gait in Cerebral Palsy: Current Concepts Review. Indian J Orthop 2023; 57:1913-1926. [PMID: 38009172 PMCID: PMC10673808 DOI: 10.1007/s43465-023-01002-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 09/10/2023] [Indexed: 11/28/2023]
Abstract
Background and Objective Crouch gait is the most common pathological gait pattern in cerebral palsy and is commonly seen in patients with spastic diplegia. It is characterized by excessive knee flexion throughout the stance phase of gait cycle. The aim of this review is to discuss the current literature about CG for a more comprehensive understanding. Methods A literature review about various aspects of crouch gait in cerebral palsy was undertaken. This included its etiology and pathophysiology, biomechanics in crouch gait, natural history of untreated crouch gait, clinical and radiological evaluation and different modalities of available treatment. Results The etiology is multifactorial and the pathophysiology is poorly understood. This makes its management challenging, thereby leading to a variety of available treatment modalities. Inadvertent lengthening of muscle-tendon units is an important cause and can be avoided. A meticulous clinical and radiological evaluation of patients, supplemented by observational and instrumented gait analysis is mandatory in choosing correct treatment modality and improving the treatment outcome. Younger children can be managed satisfactorily by various non-operative methods and spasticity reduction measures. However, crouch gait in cerebral palsy has a progressive natural history and surgical interventions are needed frequently. The current literature supports combination of various soft tissue and bony procedures as a part of single event multilevel surgery. Growth modulation in the form of anterior distal femur hemiepiphysiodesis for correction of fixed flexion deformity of knee has shown encouraging results and can be an alternative in younger children with sufficient growth remaining. Conclusions In spite of extensive research in this field, the current understanding about crouch gait has many knowledge gaps. Further studies about the etiopathogenesis and biomechanics of crouch using instrumented gait analysis are suggested. Similarly, future research should focus on the long term outcomes of different treatment modalities through comparative trials.
Collapse
Affiliation(s)
- Ritesh Arvind Pandey
- Department of Orthopaedics, All India Institute of Medical Sciences (AIIMS), Phulwari Sharif, Aurangabad Road, Patna, Bihar 801507 India
| | - Ashok N. Johari
- Children’s Orthopaedic Centre, 2nd Floor, Bobby Apartments, 143 L.J. Road, Mahim (West), Mumbai, 400016 India
| | - Triveni Shetty
- MGM School of Physiotherapy, MGM Institute of Health Sciences, Navi Mumbai, 410209 India
| |
Collapse
|
7
|
Wang Y, Zhang P, Li C. Systematic review and network meta-analysis of robot-assisted gait training on lower limb function in patients with cerebral palsy. Neurol Sci 2023; 44:3863-3875. [PMID: 37495708 PMCID: PMC10570202 DOI: 10.1007/s10072-023-06964-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 07/14/2023] [Indexed: 07/28/2023]
Abstract
OBJECTIVE This study aimed to evaluate the effectiveness of robot-assisted gait training (RAGT) in treating lower extremity function in patients with cerebral palsy (CP) and compare the efficacy differences between different robotic systems. METHODS PubMed, Web of Science, Cochrane Library, Embase, CNKI, VIP, CBM, and Wanfang databases were searched to collect randomized controlled trials of RAGT for lower extremity dysfunction in patients with CP from the time the databases were created until December 26, 2022. The D and E of Gross Motor Function Measure-88 (GMFM-88) assessed lower limb motor function. Berg Balance Scale (BBS) was used to assess balance function. Walking endurance and speed were assessed using the 6-minute walk test (6MWT) and walking speed. The modified Ashworth Scale (MAS) was used to assess the degree of muscle spasticity in the lower extremities. The Cochrane Risk Assessment Scale and the Physiotherapy Evidence Database (PEDro) scale were used for qualitative assessment in the studies included. RevMan 5.4 was used for data merging and statistical analysis. R 4.2.0 and ADDIS 1.16.8 were used to map the network relationships and to perform the network meta-analysis. RESULTS A total of 14 studies were included in the review. The meta-analysis showed that RAGT significantly improved GMFM-88 D and E, BBS, and 6MWT scores in CP patients compared with conventional rehabilitation. However, for walking speed and MAS, the intervention effect of RAGT was insignificant. The network meta-analysis showed that the best probability ranking for the effect of the 3 different robots on the GMFM-88 D score was LokoHelp (P = 0.66) > Lokomat (P = 0.28) > 3DCaLT (P = 0.06) and the best probability ranking for the GMFM-88 E score was LokoHelp (P = 0.63) > 3DCaLT (P = 0.21) > Lokomat (P = 0.16). CONCLUSION RAGT positively affects walking and balance function in patients with CP, while efficacy in improving gait speed and muscle spasticity is unknown. The best treatment among the different robots is LokoHelp. Future high-quality, long-term follow-up studies are needed to explore the clinical efficacy of RAGT in depth.
Collapse
Affiliation(s)
- Yueying Wang
- College of Rehabilitation Medicine, Shandong University of Traditional Chinese Medicine, Jinan, China
| | - Peipei Zhang
- Department of Rehabilitation Medicine, The Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China.
| | - Chao Li
- Department of Rehabilitation and Physiotherapy, The Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, China.
| |
Collapse
|
8
|
de Miguel Fernandez J, Rey-Prieto M, Rio MSD, Lopez-Matas H, Guirao-Cano L, Font-Llagunes JM, Lobo-Prat J. Adapted Assistance and Resistance Training With a Knee Exoskeleton After Stroke. IEEE Trans Neural Syst Rehabil Eng 2023; 31:3265-3274. [PMID: 37556332 DOI: 10.1109/tnsre.2023.3303777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
Studies on robotic interventions for gait rehabilitation after stroke require: (i) rigorous performance evidence; (ii) systematic procedures to tune the control parameters; and (iii) combination of control modes. In this study, we investigated how stroke individuals responded to training for two weeks with a knee exoskeleton (ABLE-KS) using both Assistance and Resistance training modes together with auditory feedback to train peak knee flexion angle. During the training, the torque provided by the ABLE-KS and the biofeedback were systematically adapted based on the subject's performance and perceived exertion level. We carried out a comprehensive experimental analysis that evaluated a wide range of biomechanical metrics, together with usability and users' perception metrics. We found significant improvements in peak knee flexion ( p = 0.0016 ), minimum knee angle during stance ( p = 0.0053 ), paretic single support time ( p = 0.0087 ) and gait endurance ( p = 0.022 ) when walking without the exoskeleton after the two weeks of training. Participants significantly ( ) improved the knee angle during the stance and swing phases when walking with the exoskeleton powered in the high Assistance mode in comparison to the No Exo and the Unpowered conditions. No clinically relevant differences were found between Assistance and Resistance training sessions. Participants improved their performance with the exoskeleton (24-55 %) for the peak knee flexion angle throughout the training sessions. Moreover, participants showed a high level of acceptability of the ABLE-KS (QUEST 2.0 score: 4.5 ± 0.3 out of 5). Our preliminary findings suggest that the proposed training approach can produce similar or larger improvements in post-stroke individuals than other studies with knee exoskeletons that used higher training intensities.
Collapse
|
9
|
Sarajchi M, Sirlantzis K. Design and Control of a Single-Leg Exoskeleton with Gravity Compensation for Children with Unilateral Cerebral Palsy. SENSORS (BASEL, SWITZERLAND) 2023; 23:6103. [PMID: 37447953 DOI: 10.3390/s23136103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 06/21/2023] [Accepted: 06/27/2023] [Indexed: 07/15/2023]
Abstract
Children with cerebral palsy (CP) experience reduced quality of life due to limited mobility and independence. Recent studies have shown that lower-limb exoskeletons (LLEs) have significant potential to improve the walking ability of children with CP. However, the number of prototyped LLEs for children with CP is very limited, while no single-leg exoskeleton (SLE) has been developed specifically for children with CP. This study aims to fill this gap by designing the first size-adjustable SLE for children with CP aged 8 to 12, covering Gross Motor Function Classification System (GMFCS) levels I to IV. The exoskeleton incorporates three active joints at the hip, knee, and ankle, actuated by brushless DC motors and harmonic drive gears. Individuals with CP have higher metabolic consumption than their typically developed (TD) peers, with gravity being a significant contributing factor. To address this, the study designed a model-based gravity-compensator impedance controller for the SLE. A dynamic model of user and exoskeleton interaction based on the Euler-Lagrange formulation and following Denavit-Hartenberg rules was derived and validated in Simscape™ and Simulink® with remarkable precision. Additionally, a novel systematic simplification method was developed to facilitate dynamic modelling. The simulation results demonstrate that the controlled SLE can improve the walking functionality of children with CP, enabling them to follow predefined target trajectories with high accuracy.
Collapse
Affiliation(s)
| | - Konstantinos Sirlantzis
- School of Engineering, Technology and Design, Canterbury Christ Church University, Canterbury, CT1 1QU, UK
| |
Collapse
|
10
|
Karunakaran KK, Pamula SD, Bach CP, Legelen E, Saleh S, Nolan KJ. Lower extremity robotic exoskeleton devices for overground ambulation recovery in acquired brain injury-A review. Front Neurorobot 2023; 17:1014616. [PMID: 37304666 PMCID: PMC10249611 DOI: 10.3389/fnbot.2023.1014616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 03/27/2023] [Indexed: 06/13/2023] Open
Abstract
Acquired brain injury (ABI) is a leading cause of ambulation deficits in the United States every year. ABI (stroke, traumatic brain injury and cerebral palsy) results in ambulation deficits with residual gait and balance deviations persisting even after 1 year. Current research is focused on evaluating the effect of robotic exoskeleton devices (RD) for overground gait and balance training. In order to understand the device effectiveness on neuroplasticity, it is important to understand RD effectiveness in the context of both downstream (functional, biomechanical and physiological) and upstream (cortical) metrics. The review identifies gaps in research areas and suggests recommendations for future research. We carefully delineate between the preliminary studies and randomized clinical trials in the interpretation of existing evidence. We present a comprehensive review of the clinical and pre-clinical research that evaluated therapeutic effects of RDs using various domains, diagnosis and stage of recovery.
Collapse
Affiliation(s)
- Kiran K. Karunakaran
- Center for Mobility and Rehabilitation Engineering Research, Kessler Foundation, West Orange, NJ, United States
- Department of Physical Medicine and Rehabilitation, Rutgers—New Jersey Medical School, Newark, NJ, United States
- Research Staff Children's Specialized Hospital New Brunswick, New Brunswick, NJ, United States
| | - Sai D. Pamula
- Center for Mobility and Rehabilitation Engineering Research, Kessler Foundation, West Orange, NJ, United States
| | - Caitlyn P. Bach
- Center for Mobility and Rehabilitation Engineering Research, Kessler Foundation, West Orange, NJ, United States
| | - Eliana Legelen
- Department of Psychology, Montclair State University, Montclair, NJ, United States
| | - Soha Saleh
- Center for Mobility and Rehabilitation Engineering Research, Kessler Foundation, West Orange, NJ, United States
- Department of Physical Medicine and Rehabilitation, Rutgers—New Jersey Medical School, Newark, NJ, United States
| | - Karen J. Nolan
- Center for Mobility and Rehabilitation Engineering Research, Kessler Foundation, West Orange, NJ, United States
- Department of Physical Medicine and Rehabilitation, Rutgers—New Jersey Medical School, Newark, NJ, United States
- Research Staff Children's Specialized Hospital New Brunswick, New Brunswick, NJ, United States
| |
Collapse
|
11
|
Cumplido-Trasmonte C, Molina-Rueda F, Puyuelo-Quintana G, Plaza-Flores A, Hernández-Melero M, Barquín-Santos E, Destarac-Eguizabal MA, García-Armada E. Satisfaction analysis of overground gait exoskeletons in people with neurological pathology. a systematic review. J Neuroeng Rehabil 2023; 20:47. [PMID: 37072823 PMCID: PMC10111693 DOI: 10.1186/s12984-023-01161-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 03/30/2023] [Indexed: 04/20/2023] Open
Abstract
BACKGROUND People diagnosed with neurological pathology may experience gait disorders that affect their quality of life. In recent years, research has been carried out on a variety of exoskeletons in this population. However, the satisfaction perceived by the users of these devices is not known. Therefore, the objective of the present study is to evaluate the satisfaction perceived by users with neurological pathology (patients and professionals) after the use of overground exoskeletons. METHODS A systematic search of five electronic databases was conducted. In order to be included in this review for further analysis, the studies had to meet the following criteria: [1] the study population was people diagnosed with neurological pathology; [2] the exoskeletons had to be overground and attachable to the lower limbs; and [3]: the studies were to include measures assessing either patient or therapist satisfaction with the exoskeletons. RESULTS Twenty-three articles were selected, of which nineteen were considered clinical trials. Participants diagnosed with stroke (n = 165), spinal cord injury (SCI) (n = 102) and multiple sclerosis (MS) (n = 68). Fourteen different overground exoskeleton models were analysed. Fourteen different methods of assessing patient satisfaction with the devices were found, and three ways to evaluate it in therapists. CONCLUSION Users' satisfaction with gait overground exoskeletons in stroke, SCI and MS seems to show positive results in safety, efficacy and comfort of the devices. However, the worst rated aspects and therefore those that should be optimized from the users' point of view are ease of adjustment, size and weight, and ease of use.
Collapse
Affiliation(s)
- C Cumplido-Trasmonte
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain.
- International Doctoral School, Rey Juan Carlos University, Madrid, 28922, Spain.
| | - F Molina-Rueda
- Department of Physical Therapy, Physical Medicine and Rehabilitation, Rey Juan Carlos University, Madrid, Spain
| | - G Puyuelo-Quintana
- International Doctoral School, Rey Juan Carlos University, Madrid, 28922, Spain
- Marsi Bionics S.L., Madrid, Spain
| | - A Plaza-Flores
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain
- Marsi Bionics S.L., Madrid, Spain
- Polytechnic University of Madrid, Madrid, Spain
| | - M Hernández-Melero
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain
| | | | | | - E García-Armada
- Centre for Automation and Robotics (CAR), CSIC-UPM, Ctra Campo Real km 0.2 - La Poveda- Arganda del Rey, Madrid, 28500, Spain.
| |
Collapse
|
12
|
Estimation of Knee Assistive Moment in a Gait Cycle Using Knee Angle and Knee Angular Velocity through Machine Learning and Artificial Stiffness Control Strategy (MLASCS). ROBOTICS 2023. [DOI: 10.3390/robotics12020044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/22/2023] Open
Abstract
Nowadays, many people around the world cannot walk perfectly because of their knee problems. A knee-assistive device is one option to support walking for those with low or not enough knee muscle forces. Many research studies have created knee devices with control systems implementing different techniques and sensors. This study proposes an alternative version of the knee device control system without using too many actuators and sensors. It applies the machine learning and artificial stiffness control strategy (MLASCS) that uses one actuator combined with an encoder for estimating the amount of assistive support in a walking gait from the recorded gait data. The study recorded several gait data and analyzed knee moments, and then trained a k-nearest neighbor model using the knee angle and the angular velocity to classify a state in a gait cycle. This control strategy also implements instantaneous artificial stiffness (IAS), a control system that requires only knee angle in each state to determine the amount of supporting moment. After validating the model via simulation, the accuracy of the machine learning model is around 99.9% with the speed of 165 observers/s, and the walking effort is reduced by up to 60% in a single gait cycle.
Collapse
|
13
|
Human Factors Assessment of a Novel Pediatric Lower-Limb Exoskeleton. ROBOTICS 2023. [DOI: 10.3390/robotics12010026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
Abstract
While several lower-limb exoskeletons have been designed for adult patients, there remains a lack of pediatric-oriented devices. This paper presented a human factor assessment of an adjustable pediatric lower-limb exoskeleton for childhood gait assistance. The hip and knee exoskeleton uses an adjustable frame for compatibility with children 6–11 years old. This assessment evaluates the device’s comfort and ease of use through timed donning, doffing, and reconfiguration tasks. The able-bodied study participants donned the device in 6 min and 8 s, doffed it in 2 min and 29 s, and reconfigured it in 8 min and 23 s. The results of the timed trials suggest that the exoskeleton can be easily donned, doffed, and reconfigured to match the anthropometrics of pediatric users. A 6-min unpowered walking experiment was conducted while the child participant wore the exoskeletal device. Inspection of both the device and participant yielded no evidence of damage to either the device or wearer. Participant feedback on the device was positive with a system usability scale rating of 80/100. While minor improvements can be made to the adjustability indicators and padding placement, the results indicate the exoskeleton is suitable for further experimental evaluation through assistive control assessments.
Collapse
|
14
|
Siviy C, Baker LM, Quinlivan BT, Porciuncula F, Swaminathan K, Awad LN, Walsh CJ. Opportunities and challenges in the development of exoskeletons for locomotor assistance. Nat Biomed Eng 2022; 7:456-472. [PMID: 36550303 DOI: 10.1038/s41551-022-00984-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2020] [Accepted: 11/08/2022] [Indexed: 12/24/2022]
Abstract
Exoskeletons can augment the performance of unimpaired users and restore movement in individuals with gait impairments. Knowledge of how users interact with wearable devices and of the physiology of locomotion have informed the design of rigid and soft exoskeletons that can specifically target a single joint or a single activity. In this Review, we highlight the main advances of the past two decades in exoskeleton technology and in the development of lower-extremity exoskeletons for locomotor assistance, discuss research needs for such wearable robots and the clinical requirements for exoskeleton-assisted gait rehabilitation, and outline the main clinical challenges and opportunities for exoskeleton technology.
Collapse
Affiliation(s)
- Christopher Siviy
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Lauren M Baker
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Brendan T Quinlivan
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Franchino Porciuncula
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.,Department of Physical Therapy, College of Health and Rehabilitation Sciences: Sargent, Boston University, Boston, MA, USA
| | - Krithika Swaminathan
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Louis N Awad
- Department of Physical Therapy, College of Health and Rehabilitation Sciences: Sargent, Boston University, Boston, MA, USA
| | - Conor J Walsh
- John A Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, USA.
| |
Collapse
|
15
|
Kennard M, Kadone H, Shimizu Y, Suzuki K. Passive Exoskeleton with Gait-Based Knee Joint Support for Individuals with Cerebral Palsy. SENSORS (BASEL, SWITZERLAND) 2022; 22:8935. [PMID: 36433532 PMCID: PMC9699336 DOI: 10.3390/s22228935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2022] [Revised: 11/15/2022] [Accepted: 11/15/2022] [Indexed: 06/16/2023]
Abstract
Cerebral palsy is a neurological disorder with a variety of symptoms that can affect muscle coordination and movement. Crouch gait is one such symptom that is defined as excessive knee flexion accompanied by a crouched posture. This paper introduces a passive exoskeleton to support the knee joint during stance of individuals with cerebral palsy that are affected by crouch gait. The exoskeleton utilizes a hydraulic disc brake mechanism that is actuated only by the body weight and gait of the wearer to provide a braking torque at the knee joint. This passive, gait-based control method aims to offer a compact, lightweight, and simple alternative to existing exoskeletons. Preliminary experiments were conducted to verify the mechanics, safety, and braking capabilities of the device with healthy participants. A pilot study with an individual with cerebral palsy was then conducted. The individual with cerebral palsy showed a reduction in hip joint angle when using the device (18.8∘ and 21.7∘ for left and right sides, respectively). The muscle co-activation index was also reduced from 0.48 to 0.24 on the right side and from 0.17 to 0.017 on the left side. However, changes such as activation timing and device training need to be improved to better support the user.
Collapse
Affiliation(s)
- Maxwell Kennard
- School of Integrative and Global Majors, University of Tsukuba, Tsukuba 305-8577, Japan
| | - Hideki Kadone
- Center for Cybernics Research and Center for Innovative Medicine and Engineering, University of Tsukuba Hospital, Tsukuba 305-8577, Japan
| | - Yukiyo Shimizu
- Department of Rehabilitation Medicine, Faculty of Medicine, University of Tsukuba, Tsukuba 305-8577, Japan
| | - Kenji Suzuki
- Faculty of Systems, Information and Engineering, University of Tsukuba, Tsukuba 305-8577, Japan
| |
Collapse
|
16
|
Hunt M, Everaert L, Brown M, Muraru L, Hatzidimitriadou E, Desloovere K. Effectiveness of robotic exoskeletons for improving gait in children with cerebral palsy: A systematic review. Gait Posture 2022; 98:343-354. [PMID: 36306544 DOI: 10.1016/j.gaitpost.2022.09.082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 07/12/2022] [Accepted: 09/19/2022] [Indexed: 02/02/2023]
Abstract
BACKGROUND Robotic exoskeletons have been developed to assist locomotion and address gait abnormalities in children with cerebral palsy (CP). These wearable assistive devices provide powered assistance to the lower-extremity joints, as well as support and stability. RESEARCH QUESTION Does exoskeleton-assisted walking improve gait in children with CP? METHODS The PRISMA guidelines were used to conduct this systematic review. Articles were obtained in a search of the following electronic databases: Embase, CINAHL Complete, PubMed, Web of Science and MEDLINE. Studies investigating spatiotemporal, kinematic, kinetic, muscle activity and/or physiological parameters during exoskeleton-assisted walking in children with CP were included. All articles were assessed for methodological quality using an adapted version of the Quality Assessment Tool for Before-After (Pre-Post) Studies with No Control Group, provided by the National Institutes of Health (NIH). RESULTS Thirteen studies were included. They involved the use of the following exoskeletons: tethered knee exoskeleton, pediatric knee exoskeleton (P.REX), untethered ankle exoskeleton, WAKE-Up ankle module, WAKE-Up ankle & knee module and unilateral ankle exosuit. Methodological quality varied, with key limitations in sample size and allocated time to adapt to the exoskeleton. There was a consensus that robotic exoskeletons improve gait given careful optimisation of exoskeleton torque and sufficient exoskeleton practice time for each participant. Improvements in gait included reduced metabolic cost of walking, increased walking speed, and increased knee and hip extension during stance. Furthermore, exoskeletons with an actuated ankle module were shown to promote normal ankle rocker function. SIGNIFICANCE Robotic exoskeletons have the potential to improve the mobility of CP children and may therefore increase community participation and improve quality of life. Future work should involve larger controlled intervention studies utilising robotic exoskeletons to improve gait in children with CP. These studies should ensure sufficient exoskeleton practice time for each participant.
Collapse
Affiliation(s)
- Markus Hunt
- Section of Sport, Exercise and Rehabilitation Science, School of Psychology and Life Sciences, Canterbury Christ Church University, North Holmes Road Campus, Canterbury, Kent CT1 1QU, UK.
| | - Laure Everaert
- Clinical Motion Analysis Laboratory, University Hospital Leuven, Weligerveld 1, 3212 Pellenberg, Belgium; Department of Rehabilitation Sciences, Research Group for Neurorehabilitation (eNRGy), KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium.
| | - Mathew Brown
- Section of Sport, Exercise and Rehabilitation Science, School of Psychology and Life Sciences, Canterbury Christ Church University, North Holmes Road Campus, Canterbury, Kent CT1 1QU, UK.
| | - Luiza Muraru
- Mobilab & Care, Thomas More University of Applied Sciences, Kleinhoefstraat 4, Geel, Belgium.
| | - Eleni Hatzidimitriadou
- Faculty of Medicine, Health and Social Care, Canterbury Christ Church University, North Holmes Road Campus, Canterbury, Kent CT1 1QU, UK.
| | - Kaat Desloovere
- Clinical Motion Analysis Laboratory, University Hospital Leuven, Weligerveld 1, 3212 Pellenberg, Belgium; Department of Rehabilitation Sciences, Research Group for Neurorehabilitation (eNRGy), KU Leuven, Tervuursevest 101, 3001 Leuven, Belgium.
| |
Collapse
|
17
|
A Wearable Lower Limb Exoskeleton: Reducing the Energy Cost of Human Movement. MICROMACHINES 2022; 13:mi13060900. [PMID: 35744514 PMCID: PMC9229674 DOI: 10.3390/mi13060900] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 05/29/2022] [Accepted: 05/30/2022] [Indexed: 01/27/2023]
Abstract
Human body enhancement is an interesting branch of robotics. It focuses on wearable robots in order to improve the performance of human body, reduce energy consumption and delay fatigue, as well as increase body speed. Robot-assisted equipment, such as wearable exoskeletons, are wearable robot systems that integrate human intelligence and robot power. After careful design and adaptation, the human body has energy-saving sports, but it is an arduous task for the exoskeleton to achieve considerable reduction in metabolic rate. Therefore, it is necessary to understand the biomechanics of human sports, the body, and its weaknesses. In this study, a lower limb exoskeleton was classified according to the power source, and the working principle, design idea, wearing mode, material and performance of different types of lower limb exoskeletons were compared and analyzed. The study shows that the unpowered exoskeleton robot has inherent advantages in endurance, mass, volume, and cost, which is a new development direction of robot exoskeletons. This paper not only summarizes the existing research but also points out its shortcomings through the comparative analysis of different lower limb wearable exoskeletons. Furthermore, improvement measures suitable for practical application have been provided.
Collapse
|
18
|
Lora-Millan JS, Moreno JC, Rocon E. Coordination Between Partial Robotic Exoskeletons and Human Gait: A Comprehensive Review on Control Strategies. Front Bioeng Biotechnol 2022; 10:842294. [PMID: 35694226 PMCID: PMC9174608 DOI: 10.3389/fbioe.2022.842294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Accepted: 04/28/2022] [Indexed: 12/02/2022] Open
Abstract
Lower-limb robotic exoskeletons have become powerful tools to assist or rehabilitate the gait of subjects with impaired walking, even when they are designed to act only partially over the locomotor system, as in the case of unilateral or single-joint exoskeletons. These partial exoskeletons require a proper method to synchronize their assistive actions and ensure correct inter-joint coordination with the user’s gait. This review analyzes the state of the art of control strategies to coordinate the assistance provided by these partial devices with the actual gait of the wearers. We have analyzed and classified the different approaches independently of the hardware implementation, describing their basis and principles. We have also reviewed the experimental validations of these devices for impaired and unimpaired walking subjects to provide the reader with a clear view of their technology readiness level. Eventually, the current state of the art and necessary future steps in the field are summarized and discussed.
Collapse
Affiliation(s)
- Julio S. Lora-Millan
- Centre for Automation and Robotics, Consejo Superior de Investigaciones Científicas-Universidad Politécnica de Madrid, CSIC-UPM, Madrid, Spain
- Electronic Technology Department, Universidad Rey Juan Carlos, Madrid, Spain
| | - Juan C. Moreno
- Neural Rehabilitation Group, Cajal Institute, Spanish National Research Council (CSIC), Madrid, Spain
| | - E. Rocon
- Centre for Automation and Robotics, Consejo Superior de Investigaciones Científicas-Universidad Politécnica de Madrid, CSIC-UPM, Madrid, Spain
- *Correspondence: E. Rocon,
| |
Collapse
|
19
|
Tanyildizi AK, Tasar B, Yakut O. Design of a robotic exo-suit for knee lateral support with an interaction control based on relative motion angle. J MECH MED BIOL 2022. [DOI: 10.1142/s0219519422500336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
20
|
Research on the Correlation between Multisource Big Data Virtual Assisted Preschool Education and the Development of Children’s Innovative Ability. Occup Ther Int 2022; 2022:3880201. [PMID: 35572165 PMCID: PMC9068341 DOI: 10.1155/2022/3880201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2022] [Revised: 04/02/2022] [Accepted: 04/06/2022] [Indexed: 11/17/2022] Open
Abstract
Objective. Innovation ability is an important part of children’s core literacy and the core goal of science curriculum. As one of the important contents of scientific literacy, innovation ability is the key ability of young children to make informed decisions when facing scientific problems in social and personal life. In order to adapt to the future life, it is very important for children to have the ability to innovate. This research will provide a reference for the cultivation of children’s innovative ability. Method. In the process of database design, certain design principles need to be followed. In this paper, the system and user experience are greatly optimized by reasonably constructing table structure, allocating storage space, and establishing indexes. In this system, the MySQL database is used to store system data, such as user registration information, subscription information, and system-provided services, and the data uploaded by users that needs to be processed is stored in Hive. Although the GFP algorithm can solve the problem of load balancing, when the largest conditional pattern base of a frequent item is projected to other nodes, a large amount of data transmission will occur, resulting in increased communication between nodes. In order to solve this problem, the FP-growth parallel algorithm based on traffic optimization gives priority to assigning each frequent item to the node that needs the least traffic when grouping it. Results/Discussion. Experiments show that the TFP algorithm not only satisfies the load balance of nodes but also ensures a small amount of communication between nodes, which is more efficient than the traditional FP-growth parallel algorithm. The survey results of the influencing factors of children’s innovation ability match the theoretical hypothesis, and different influencing factors have different effects on each dimension of children’s innovation ability. Through the basic fit index of the model, the evaluation of the external quality of the model and the test of the internal quality of the model, it is shown that the survey results of the influencing factors of children’s innovation ability match the theoretical hypothesis. The three influencing factors of family participation and investment, teacher teaching, and peer collaboration and communication have a positive role in promoting children’s innovation ability.
Collapse
|
21
|
Cho S, Lee KD, Park HS. A Mobile Cable-Tensioning Platform to Improve Crouch Gait in Children with Cerebral Palsy. IEEE Trans Neural Syst Rehabil Eng 2022; 30:1092-1102. [PMID: 35442888 DOI: 10.1109/tnsre.2022.3167472] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Gait impairment represented by crouch gait is the main cause of decreases in the quality of lives of children with cerebral palsy. Various robotic rehabilitation interventions have been used to improve gait abnormalities in the sagittal plane of children with cerebral palsy, such as excessive flexion in the hip and knee joints, yet in few studies have postural improvements in the coronal plane been observed. The aim of this study was to design and validate a gait rehabilitation system using a new cable-driven mechanism applying assist in the coronal plane. We developed a mobile cable-tensioning platform that can control the magnitude and direction of the tension vector applied at the knee joints during treadmill walking, while minimizing the inertia of the worn part of the device for less obstructing the natural movement of the lower limbs. To validate the effectiveness of the proposed system, three different treadmill walking conditions were performed by four children with cerebral palsy. The experimental results showed that the system reduced hip adduction angle by an average of 4.57 ± 1.79° compared to unassisted walking. Importantly, we also observed improvements of hip joint kinematics in the sagittal plane, indicating that crouch gait can be improved by postural correction in the coronal plane. The device also improved anterior and lateral pelvic tilts during treadmill walking. The proposed cable-tensioning platform can be used as a rehabilitation system for crouch gait, and more specifically, for correcting gait posture with minimal disturbance to the voluntary movement.
Collapse
|
22
|
Singh Y, Vashista V. Gait Classification with Gait Inherent Attribute Identification from Ankle's Kinematics. IEEE Trans Neural Syst Rehabil Eng 2022; 30:833-842. [PMID: 35324446 DOI: 10.1109/tnsre.2022.3162035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The human ankle joint interacts with the environment during ambulation to provide mobility and maintain stability. This association changes depending on the different gait patterns of day-to-day life. In this study, we investigated this interaction and extracted kinematic information to classify human walking mode into upstairs, downstairs, treadmill, overground and stationary in real-time using a single-DoF IMU axis. The proposed algorithm's uniqueness is twofold - it encompasses components of the ankle's biomechanics and subject-specificity through the extraction of inherent walking attributes and user calibration. The performance analysis with forty healthy participants (mean age: 26.8 ± 5.6 years yielded an accuracy of 89.57% and 87.55% in the left and right sensors, respectively. The study, also, portrays the implementation of heuristics to combine predictions from sensors at both feet to yield a single conclusive decision with better performance measures. The simplicity yet reliability of the algorithm in healthy participants and the observation of inherent multimodal walking features, similar to young adults, in elderly participants through a case study, demonstrate our proposed algorithm's potential as a high-level automatic switching framework in robotic gait interventions for multimodal walking.
Collapse
|
23
|
Manikowska F, Brazevic S, Krzyżańska A, Jóźwiak M. Effects of Robot-Assisted Therapy on Gait Parameters in Pediatric Patients With Spastic Cerebral Palsy. Front Neurol 2022; 12:724009. [PMID: 35002911 PMCID: PMC8732368 DOI: 10.3389/fneur.2021.724009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 11/11/2021] [Indexed: 11/25/2022] Open
Abstract
Background: Gait dysfunction is a crucial factor that restricts independence and quality of life in children with cerebral palsy (CP). Gait training based on robotic-assisted therapy (RAT) is widely used, but information about effectiveness and ideal patient profile is not sufficient. Aim of this study was to assess the effect of RAT on gait parameters in spastic children with CP, and to determine whether changes in gait parameters are different among patients on different ambulatory levels. Method: A total of 26 children with bilateral spastic CP were divided into two groups based on their functional ability: non-assisted ambulator (NAS) or assisted ambulator (AS); and underwent a RAT program (30 training sessions of RAT during 10 weeks). Gait analysis was performed: before the therapy (t1), right after (t2), and 6 weeks later (t3). Results: No significant changes in spatiotemporal parameters or gait deviation index at t2 or t3. Double support symmetry significantly improved (t1 vs. t3, p = 0.03) for the whole group (NAS + AS). Walking speed symmetry significantly improved (t2 vs. t3, p = 0.02) for group AS. Conclusion: RAT based on our protocol did not change spatiotemporal parameters and kinematics of walking except limited improvement in some aspects of gait symmetry. We did not find differences in changes in selected objective gait parameters among children with CP in different ambulatory levels.
Collapse
Affiliation(s)
- Faustyna Manikowska
- Gait and Motion Analysis Laboratory, Poznań University of Medical Sciences, Poznań, Poland
| | - Sabina Brazevic
- Gait and Motion Analysis Laboratory, Poznań University of Medical Sciences, Poznań, Poland
| | | | - Marek Jóźwiak
- Gait and Motion Analysis Laboratory, Poznań University of Medical Sciences, Poznań, Poland
| |
Collapse
|
24
|
Huang TH, Zhang S, Yu S, MacLean MK, Zhu J, Di Lallo A, Jiao C, Bulea TC, Zheng M, Su H. Modeling and Stiffness-Based Continuous Torque Control of Lightweight Quasi-Direct-Drive Knee Exoskeletons for Versatile Walking Assistance. IEEE T ROBOT 2022; 38:1442-1459. [DOI: 10.1109/tro.2022.3170287] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Tzu-Hao Huang
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Sainan Zhang
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Shuangyue Yu
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Mhairi K. MacLean
- Laboratory of Biomechatronics and Intelligent Robotics 57522, Enschede The Netherlands, and also with the Department of Mechanical Engineering, University of Twente 57522, Enschede The Netherlands
| | - Junxi Zhu
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Antonio Di Lallo
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Chunhai Jiao
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Thomas C. Bulea
- Functional and Applied Biomechanics Section, Rehabilitation Medicine Department, Clinical Center, National Institutes of Health, Bethesda, MD 20892 USA
| | - Minghui Zheng
- Department of Mechanical and Aerospace Engineering, University at Buffalo, Buffalo, NY 14260 USA
| | - Hao Su
- Laboratory of Biomechatronics and Intelligent Robotics, Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| |
Collapse
|
25
|
Electromechanical and Robotic Devices for Gait and Balance Rehabilitation of Children with Neurological Disability: A Systematic Review. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app112412061] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In the last two decades, a growing interest has been focused on gait and balance robot-assisted rehabilitation in children with neurological disabilities. Robotic devices allow the implementation of intensive, task-specific training fostering functional recovery and neuroplasticity phenomena. However, limited attention has been paid to the protocols used in this research framework. This systematic review aims to provide an overview of the existing literature on robotic systems for the rehabilitation of gait and balance in children with neurological disabilities and their rehabilitation applications. The literature search was carried out independently and synchronously by three authors on the following databases: MEDLINE, Cochrane Library, PeDro, Institute of Electrical and Electronics Engineers, ScienceDirect, and Google Scholar. The data collected included three subsections referring to clinical, technical, and regulatory aspects. Thirty-one articles out of 81 found on the primary literature search were included in the systematic review. Most studies involved children with cerebral palsy. Only one-third of the studies were randomized controlled trials. Overall, 17 devices (nine end-effector systems and eight exoskeletons) were investigated, among which only 4 (24%) were bore the CE mark. Studies differ on rehabilitation protocols duration, intensity, and outcome measures. Future research should improve both rehabilitation protocols’ and devices’ descriptions.
Collapse
|
26
|
Sarajchi M, Al-Hares MK, Sirlantzis K. Wearable Lower-Limb Exoskeleton for Children With Cerebral Palsy: A Systematic Review of Mechanical Design, Actuation Type, Control Strategy, and Clinical Evaluation. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2695-2720. [PMID: 34910636 DOI: 10.1109/tnsre.2021.3136088] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Children with a neurological disorder such as cerebral palsy (CP) severely suffer from a reduced quality of life because of decreasing independence and mobility. Although there is no cure yet, a lower-limb exoskeleton (LLE) has considerable potential to help these children experience better mobility during overground walking. The research in wearable exoskeletons for children with CP is still at an early stage. This paper shows that the number of published papers on LLEs assisting children with CP has significantly increased in recent years; however, no research has been carried out to review these studies systematically. To fill up this research gap, a systematic review from a technical and clinical perspective has been conducted, based on the PRISMA guidelines, under three extended topics associated with "lower limb", "exoskeleton", and "cerebral palsy" in the databases Scopus and Web of Science. After applying several exclusion criteria, seventeen articles focused on fifteen LLEs were included for careful consideration. These studies address some consistent positive evidence on the efficacy of LLEs in improving gait patterns in children with CP. Statistical findings show that knee exoskeletons, brushless DC motors, the hierarchy control architecture, and CP children with spastic diplegia are, respectively, the most common mechanical design, actuator type, control strategy, and clinical characteristics for these LLEs. Clinical studies suggest ankle-foot orthosis as the primary medical solution for most CP gait patterns; nevertheless, only one motorized ankle exoskeleton has been developed. This paper shows that more research and contribution are needed to deal with open challenges in these LLEs.
Collapse
|
27
|
Wang C, Dai L, Shen D, Wu J, Wang X, Tian M, Shi Y, Su C. Design of an Ankle Exoskeleton that Recycles Energy to Assist Propulsion during Human Walking. IEEE Trans Biomed Eng 2021; 69:1212-1224. [PMID: 34665715 DOI: 10.1109/tbme.2021.3120716] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
AbstractObjective: Active exoskeletons can handle different walking conditions, but require bulky components (e.g., motors) that need a significant source of power to do so. Purely passive exoskeletons are lightweight and energy-neutral, containing energy-recycling mechanisms that capture energy loss during negative power phases and return it as walking assistance. However, they are usually designed for stereotyped gaits (e.g., walking at fixed speed) and thus show poor adaptivity for variable conditions. This study is aimed to overcome these issues. METHODS A quasi-passive ankle exoskeleton is designed to integrate the merits of both active and passive exoskeletons, which captures the heel-strike energy loss and recycles it into propulsion. A novel, lightweight, energy-saving clutch and a heel-strike energy-storage mechanism are developed. They are coupled by a series spring that assists users calf muscles. Six healthy subjects walked with the device on level ground and inclined surfaces to validate its functionality. RESULTS Level ground studies indicate that the energy-storage mechanism enhances the assistance by increasing the output torque of the exoskeleton. Reductions in metabolic cost (6.4 1.3%, p < 0.05) were observed. During uphill walking, the assistance torque decreased compared with that on level ground, but it still reduced overall metabolic cost compared with baseline walking. During downhill walking, the assistance torque increased, but metabolic cost also slightly increased. CONCLUSION These results demonstrate the functionality of the prototype on level ground and its limitations on inclined surfaces. SIGNIFICANCE The proposed device highlights the possibility of widening the potential applications of exoskeletons.
Collapse
|
28
|
Laubscher CA, Farris RJ, van den Bogert AJ, Sawicki JT. An Anthropometrically Parameterized Assistive Lower Limb Exoskeleton. J Biomech Eng 2021; 143:105001. [PMID: 34008845 DOI: 10.1115/1.4051214] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Indexed: 01/04/2023]
Abstract
This paper presents an innovative design methodology for development of lower limb exoskeletons with the fabrication and experimental evaluation of prototype hardware. The proposed design approach is specifically conceived to be suitable for the pediatric population and uses additive manufacturing and a model parameterized in terms of subject anthropometrics to give a person-specific custom fit. The methodology is applied to create computer-aided design models using average anthropometrics of children 6-11 years old and using anthropometrics of an individual measured by the researchers. This demonstrates that the approach can scale to subject weight and height. A prototype exoskeleton is fabricated, which can actuate the hip and knee joints without restricting hip abduction-adduction motion. In order to test usability of the device and evaluate walking assistance, user effort is quantified in an assisted condition where the subject walks on a level treadmill with the exoskeleton powered. This is compared to an unassisted condition with the exoskeleton unpowered and a baseline condition with the subject not wearing the exoskeleton. Comparing assisted to baseline conditions, torque magnitudes increased at the hip and knee, mechanical energy generated increased at the hip but decreased at the knee, and muscle activations increased in the Vastus Lateralis but decreased in the Biceps Femoris. While the preliminary evidence for walking assistance is not entirely convincing for the tested conditions, the presented design methodology itself is promising as it has been successfully validated through the creation of computer-aided design models for children and fabrication of a serviceable exoskeleton prototype.
Collapse
Affiliation(s)
- Curt A Laubscher
- Department of Mechanical Engineering, Cleveland State University, Center for Rotating Machinery Dynamics and Control, Cleveland, OH 44115
| | - Ryan J Farris
- Human Motion and Control Division, Parker Hannifin Corporation, Macedonia, OH 44056
| | - Antonie J van den Bogert
- Department of Mechanical Engineering, Cleveland State University, Center for Human-Machine Systems, Cleveland, OH 44115
| | - Jerzy T Sawicki
- Department of Mechanical Engineering, Cleveland State University, Center for Rotating Machinery Dynamics and Control, Cleveland, OH 44115
| |
Collapse
|
29
|
Gonzalez A, Garcia L, Kilby J, McNair P. Robotic devices for paediatric rehabilitation: a review of design features. Biomed Eng Online 2021; 20:89. [PMID: 34488777 PMCID: PMC8420060 DOI: 10.1186/s12938-021-00920-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Accepted: 08/06/2021] [Indexed: 01/11/2023] Open
Abstract
Children with physical disabilities often have limited performance in daily activities, hindering their physical development, social development and mental health. Therefore, rehabilitation is essential to mitigate the adverse effects of the different causes of physical disabilities and improve independence and quality of life. In the last decade, robotic rehabilitation has shown the potential to augment traditional physical rehabilitation. However, to date, most robotic rehabilitation devices are designed for adult patients who differ in their needs compared to paediatric patients, limiting the devices' potential because the paediatric patients' needs are not adequately considered. With this in mind, the current work reviews the existing literature on robotic rehabilitation for children with physical disabilities, intending to summarise how the rehabilitation robots could fulfil children's needs and inspire researchers to develop new devices. A literature search was conducted utilising the Web of Science, PubMed and Scopus databases. Based on the inclusion-exclusion criteria, 206 publications were included, and 58 robotic devices used by children with a physical disability were identified. Different design factors and the treated conditions using robotic technology were compared. Through the analyses, it was identified that weight, safety, operability and motivation were crucial factors to the successful design of devices for children. The majority of the current devices were used for lower limb rehabilitation. Neurological disorders, in particular cerebral palsy, were the most common conditions for which devices were designed. By far, the most common actuator was the electric motor. Usually, the devices present more than one training strategy being the assistive strategy the most used. The admittance/impedance method is the most popular to interface the robot with the children. Currently, there is a trend on developing exoskeletons, as they can assist children with daily life activities outside of the rehabilitation setting, propitiating a wider adoption of the technology. With this shift in focus, it appears likely that new technologies to actuate the system (e.g. serial elastic actuators) and to detect the intention (e.g. physiological signals) of children as they go about their daily activities will be required.
Collapse
Affiliation(s)
- Alberto Gonzalez
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| | - Lorenzo Garcia
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand.
| | - Jeff Kilby
- BioDesign Lab, School of Engineering, Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand
| | - Peter McNair
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland, New Zealand
| |
Collapse
|
30
|
Review of control strategies for lower-limb exoskeletons to assist gait. J Neuroeng Rehabil 2021; 18:119. [PMID: 34315499 PMCID: PMC8314580 DOI: 10.1186/s12984-021-00906-3] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Accepted: 06/25/2021] [Indexed: 12/20/2022] Open
Abstract
Background Many lower-limb exoskeletons have been developed to assist gait, exhibiting a large range of control methods. The goal of this paper is to review and classify these control strategies, that determine how these devices interact with the user. Methods In addition to covering the recent publications on the control of lower-limb exoskeletons for gait assistance, an effort has been made to review the controllers independently of the hardware and implementation aspects. The common 3-level structure (high, middle, and low levels) is first used to separate the continuous behavior (mid-level) from the implementation of position/torque control (low-level) and the detection of the terrain or user’s intention (high-level). Within these levels, different approaches (functional units) have been identified and combined to describe each considered controller. Results 291 references have been considered and sorted by the proposed classification. The methods identified in the high-level are manual user input, brain interfaces, or automatic mode detection based on the terrain or user’s movements. In the mid-level, the synchronization is most often based on manual triggers by the user, discrete events (followed by state machines or time-based progression), or continuous estimations using state variables. The desired action is determined based on position/torque profiles, model-based calculations, or other custom functions of the sensory signals. In the low-level, position or torque controllers are used to carry out the desired actions. In addition to a more detailed description of these methods, the variants of implementation within each one are also compared and discussed in the paper. Conclusions By listing and comparing the features of the reviewed controllers, this work can help in understanding the numerous techniques found in the literature. The main identified trends are the use of pre-defined trajectories for full-mobilization and event-triggered (or adaptive-frequency-oscillator-synchronized) torque profiles for partial assistance. More recently, advanced methods to adapt the position/torque profiles online and automatically detect terrains or locomotion modes have become more common, but these are largely still limited to laboratory settings. An analysis of the possible underlying reasons of the identified trends is also carried out and opportunities for further studies are discussed. Supplementary Information The online version contains supplementary material available at 10.1186/s12984-021-00906-3.
Collapse
|
31
|
Chen J, Hochstein J, Kim C, Tucker L, Hammel LE, Damiano DL, Bulea TC. A Pediatric Knee Exoskeleton With Real-Time Adaptive Control for Overground Walking in Ambulatory Individuals With Cerebral Palsy. Front Robot AI 2021; 8:702137. [PMID: 34222356 PMCID: PMC8249803 DOI: 10.3389/frobt.2021.702137] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Accepted: 05/27/2021] [Indexed: 11/13/2022] Open
Abstract
Gait training via a wearable device in children with cerebral palsy (CP) offers the potential to increase therapy dosage and intensity compared to current approaches. Here, we report the design and characterization of a pediatric knee exoskeleton (P.REX) with a microcontroller based multi-layered closed loop control system to provide individualized control capability. Exoskeleton performance was evaluated through benchtop and human subject testing. Step response tests show the averaged 90% rise was 26 ± 0.2 ms for 5 Nm, 22 ± 0.2 ms for 10 Nm, 32 ± 0.4 ms for 15 Nm. Torque bandwidth of P.REX was 12 Hz and output impedance was less than 1.8 Nm with control on (Zero mode). Three different control strategies can be deployed to apply assistance to knee extension: state-based assistance, impedance-based trajectory tracking, and real-time adaptive control. One participant with typical development (TD) and one participant with crouch gait from CP were recruited to evaluate P.REX in overground walking tests. Data from the participant with TD were used to validate control system performance. Kinematic and kinetic data were collected by motion capture and compared to exoskeleton on-board sensors to evaluate control system performance with results demonstrating that the control system functioned as intended. The data from the participant with CP are part of a larger ongoing study. Results for this participant compare walking with P.REX in two control modes: a state-based approach that provided constant knee extension assistance during early stance, mid-stance and late swing (Est+Mst+Lsw mode) and an Adaptive mode providing knee extension assistance proportional to estimated knee moment during stance. Both were well tolerated and significantly improved knee extension compared to walking without extension assistance (Zero mode). There was less reduction in gait speed during use of the adaptive controller, suggesting that it may be more intuitive than state-based constant assistance for this individual. Future work will investigate the effects of exoskeleton assistance during overground gait training in children with neurological disorders and will aim to identify the optimal individualized control strategy for exoskeleton prescription.
Collapse
Affiliation(s)
- Ji Chen
- Biomedical Engineering Program, Department of Mechanical Engineering, University of the District of Columbia, Washington, DC, United States
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Jon Hochstein
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Christina Kim
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Luke Tucker
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Lauren E. Hammel
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Diane L. Damiano
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| | - Thomas C. Bulea
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD, United States
| |
Collapse
|
32
|
Fang Y, Lerner ZF. Feasibility of Augmenting Ankle Exoskeleton Walking Performance With Step Length Biofeedback in Individuals With Cerebral Palsy. IEEE Trans Neural Syst Rehabil Eng 2021; 29:442-449. [PMID: 33523814 PMCID: PMC7968126 DOI: 10.1109/tnsre.2021.3055796] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Most people with cerebral palsy (CP) suffer from impaired walking ability and pathological gait patterns. Seeking to improve the effectiveness of gait training in this patient population, this study developed and assessed the feasibility of a real-time biofeedback mechanism to augment untethered ankle exoskeleton-assisted walking performance in individuals with CP. We selected step length as a clinically-relevant gait performance target and utilized a visual interface with live performance scores. An adaptive ankle exoskeleton control algorithm provided assistance proportional to the real-time ankle moment. We assessed lower-extremity gait mechanics and muscle activity in seven ambulatory individuals with CP as they walked with adaptive ankle assistance alone and with ankle assistance plus step-length biofeedback. We achieved our technical validation goal by demonstrating a strong correlation between estimated step length and real step length (R = 0.771, p < 0.001). We achieved our clinical feasibility goal by demonstrating that biofeedback-plus-assistance resulted in a 14% increase in step length relative to baseline (p ≤ 0.05), while no difference in step length was observed for assistance alone. Additionally, we observed near immediate improvements in lower-extremity posture, moments, and positive power relative to baseline for biofeedback-plus-assistance (p < 0.05), with none, or more-limited improvements observed for assistance alone. Our findings suggest that providing real-time biofeedback and using step length as the target can be effective for increasing the rate at which individuals with CP improve their gait mechanics when walking with wearable ankle assistance.
Collapse
|
33
|
Rodríguez-Fernández A, Lobo-Prat J, Font-Llagunes JM. Systematic review on wearable lower-limb exoskeletons for gait training in neuromuscular impairments. J Neuroeng Rehabil 2021; 18:22. [PMID: 33526065 PMCID: PMC7852187 DOI: 10.1186/s12984-021-00815-5] [Citation(s) in RCA: 97] [Impact Index Per Article: 32.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 01/12/2021] [Indexed: 02/08/2023] Open
Abstract
Gait disorders can reduce the quality of life for people with neuromuscular impairments. Therefore, walking recovery is one of the main priorities for counteracting sedentary lifestyle, reducing secondary health conditions and restoring legged mobility. At present, wearable powered lower-limb exoskeletons are emerging as a revolutionary technology for robotic gait rehabilitation. This systematic review provides a comprehensive overview on wearable lower-limb exoskeletons for people with neuromuscular impairments, addressing the following three questions: (1) what is the current technological status of wearable lower-limb exoskeletons for gait rehabilitation?, (2) what is the methodology used in the clinical validations of wearable lower-limb exoskeletons?, and (3) what are the benefits and current evidence on clinical efficacy of wearable lower-limb exoskeletons? We analyzed 87 clinical studies focusing on both device technology (e.g., actuators, sensors, structure) and clinical aspects (e.g., training protocol, outcome measures, patient impairments), and make available the database with all the compiled information. The results of the literature survey reveal that wearable exoskeletons have potential for a number of applications including early rehabilitation, promoting physical exercise, and carrying out daily living activities both at home and the community. Likewise, wearable exoskeletons may improve mobility and independence in non-ambulatory people, and may reduce secondary health conditions related to sedentariness, with all the advantages that this entails. However, the use of this technology is still limited by heavy and bulky devices, which require supervision and the use of walking aids. In addition, evidence supporting their benefits is still limited to short-intervention trials with few participants and diversity among their clinical protocols. Wearable lower-limb exoskeletons for gait rehabilitation are still in their early stages of development and randomized control trials are needed to demonstrate their clinical efficacy.
Collapse
Affiliation(s)
- Antonio Rodríguez-Fernández
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain. .,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.
| | - Joan Lobo-Prat
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain.,Institut de Robòtica i Informàtica Industrial, CSIC-UPC, Llorens i Artigas 4-6, 08028, Barcelona, Spain
| | - Josep M Font-Llagunes
- Biomechanical Engineering Lab, Department of Mechanical Engineering and Research Center for Biomedical Engineering, Universitat Politècnica de Catalunya, Diagonal 647, 08028, Barcelona, Spain.,Institut de Recerca Sant Joan de Déu, Santa Rosa 39-57, 08950, Esplugues de Llobregat, Spain.,ABLE Human Motion, Diagonal 647, 08028, Barcelona, Spain
| |
Collapse
|
34
|
Abstract
Lower-limb exoskeletons have undergone significant developments for aiding in the ambulation of adults with gait impairment. However, advancements in exoskeletons for the pediatric population have comparatively been lacking. This paper presents a newly developed joint actuator designed to drive the hip and knee joints of a pediatric lower-limb exoskeleton. The performance requirements associated with the actuators were determined based on a target audience of children ages 6–11 years old. The developed actuators incorporate a hybrid belt-chain transmission driven by a frameless brushless DC motor. One actuator underwent benchtop testing to evaluate its performance with respect to their torque production, bandwidth properties, backdrivability in terms of inertia and friction characteristics, speed capabilities, and operational noise levels. As a preliminary validation, a set of actuators were placed in a prototype orthosis to move a pediatric test dummy in gait tracking via state-feedback control. The results showed that the newly developed actuators meet the design specifications and are suitable for use in the pediatric exoskeleton being developed.
Collapse
|
35
|
Karunakaran KK, Abbruzzese K, Androwis G, Foulds RA. A Novel User Control for Lower Extremity Rehabilitation Exoskeletons. Front Robot AI 2020; 7:108. [PMID: 33501275 PMCID: PMC7805763 DOI: 10.3389/frobt.2020.00108] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 07/13/2020] [Indexed: 01/28/2023] Open
Abstract
Lower extremity exoskeletons offer the potential to restore ambulation to individuals with paraplegia due to spinal cord injury. However, they often rely on preprogrammed gait, initiated by switches, sensors, and/or EEG triggers. Users can exercise only limited independent control over the trajectory of the feet, the speed of walking, and the placement of feet to avoid obstacles. In this paper, we introduce and evaluate a novel approach that naturally decodes a neuromuscular surrogate for a user's neutrally planned foot control, uses the exoskeleton's motors to move the user's legs in real-time, and provides sensory feedback to the user allowing real-time sensation and path correction resulting in gait similar to biological ambulation. Users express their desired gait by applying Cartesian forces via their hands to rigid trekking poles that are connected to the exoskeleton feet through multi-axis force sensors. Using admittance control, the forces applied by the hands are converted into desired foot positions, every 10 milliseconds (ms), to which the exoskeleton is moved by its motors. As the trekking poles reflect the resulting foot movement, users receive sensory feedback of foot kinematics and ground contact that allows on-the-fly force corrections to maintain the desired foot behavior. We present preliminary results showing that our novel control can allow users to produce biologically similar exoskeleton gait.
Collapse
Affiliation(s)
- Kiran K Karunakaran
- Kessler Foundation, West Orange, NJ, United States.,Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Kevin Abbruzzese
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States.,Stryker Corporation, Mahwah, NJ, United States
| | - Ghaith Androwis
- Kessler Foundation, West Orange, NJ, United States.,Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States
| | - Richard A Foulds
- Department of Biomedical Engineering, New Jersey Institute of Technology, Newark, NJ, United States.,Really Useful Robots, LLC, Langhorne, PA, United States
| |
Collapse
|
36
|
Shideler BL, Bulea TC, Chen J, Stanley CJ, Gravunder AJ, Damiano DL. Toward a hybrid exoskeleton for crouch gait in children with cerebral palsy: neuromuscular electrical stimulation for improved knee extension. J Neuroeng Rehabil 2020; 17:121. [PMID: 32883297 PMCID: PMC7469320 DOI: 10.1186/s12984-020-00738-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 07/29/2020] [Indexed: 11/30/2022] Open
Abstract
BACKGROUND Neuromuscular Electrical Stimulation (NMES) has been utilized for many years in cerebral palsy (CP) with limited success despite its inherent potential for improving muscle size and/or strength, inhibiting or reducing spasticity, and enhancing motor performance during functional activities such as gait. While surface NMES has been shown to successfully improve foot drop in CP and stroke, correction of more complex gait abnormalities in CP such as flexed knee (crouch) gait remains challenging due to the level of stimulation needed for the quadriceps muscles that must be balanced with patient tolerability and the ability to deliver NMES assistance at precise times within a gait cycle. METHODS This paper outlines the design and evaluation of a custom, noninvasive NMES system that can trigger and adjust electrical stimulation in real-time. Further, this study demonstrates feasibility of one possible application for this digitally-controlled NMES system as a component of a pediatric robotic exoskeleton to provide on-demand stimulation to leg muscles within specific phases of the gait cycle for those with CP and other neurological disorders who still have lower limb sensation and volitional control. A graphical user interface was developed to digitally set stimulation parameters (amplitude, pulse width, and frequency), timing, and intensity during walking. Benchtop testing characterized system delay and power output. System performance was investigated during a single session that consisted of four overground walking conditions in a 15-year-old male with bilateral spastic CP, GMFCS Level III: (1) his current Ankle-Foot Orthosis (AFO); (2) unassisted Exoskeleton; (3) NMES of the vastus lateralis; and (4) NMES of the vastus lateralis and rectus femoris. We hypothesized in this participant with crouch gait that NMES triggered with low latency to knee extensor muscles during stance would have a modest but positive effect on knee extension during stance. RESULTS The system delivers four channels of NMES with average delays of 16.5 ± 13.5 ms. Walking results show NMES to the vastus lateralis and rectus femoris during stance immediately improved mean peak knee extension during mid-stance (p = 0.003*) and total knee excursion (p = 0.009*) in the more affected leg. The electrical design, microcontroller software and graphical user interface developed here are included as open source material to facilitate additional research into digitally-controlled surface stimulation ( github.com/NIHFAB/NMES ). CONCLUSIONS The custom, digitally-controlled NMES system can reliably trigger electrical stimulation with low latency. Precisely timed delivery of electrical stimulation to the quadriceps is a promising treatment for crouch. Our ultimate goal is to synchronize NMES with robotic knee extension assistance to create a hybrid NMES-exoskeleton device for gait rehabilitation in children with flexed knee gait from CP as well as from other pediatric disorders. TRIAL REGISTRATION clinicaltrials.gov, ID: NCT01961557 . Registered 11 October 2013; Last Updated 27 January 2020.
Collapse
Affiliation(s)
- Blynn L Shideler
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Thomas C Bulea
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Ji Chen
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Christopher J Stanley
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Andrew J Gravunder
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA
| | - Diane L Damiano
- National Institutes of Health, Clinical Center, Rehabilitation Medicine Department, Functional & Applied Biomechanics Section, Bldg 10 CRC Rm 1-1469, 10 Center Dr. MSC 1604, Bethesda, MD, 20892-1604, USA.
| |
Collapse
|
37
|
Lobato Garcia L, González González Y, Da Cuña Carrera I, Alonso Calvete A. [Benefits of robotics in gait rehabilitation in cerebral palsy: A systematic review]. Rehabilitacion (Madr) 2020; 54:128-136. [PMID: 32370827 DOI: 10.1016/j.rh.2020.01.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Revised: 11/01/2019] [Accepted: 01/11/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND AIM Cerebral palsy is the most common motor disability in childhood, with an estimated incidence of two out of every 1,000 live births. The impairment mostly affects gait. The aim of rehabilitation programmes is to enhance independence in affected individuals, especially mobility. To do this, robot-assisted gait rehabilitation programmes have been developed. Therefore, this study aimed to identify the benefits of robotics in gait rehabilitation in cerebral palsy. MATERIAL AND METHODS We performed a literature search using the MeSH terms «cerebral palsy», «robotics» and «gait». RESULTS After applying the selection criteria, we obtained 10 research studies and three protocols analysing the benefits of robotics in cerebral palsy and demonstrating that their use provides major advantages.
Collapse
Affiliation(s)
- L Lobato Garcia
- Facultad de Fisioterapia, Universidade de Vigo, Vigo, Pontevedra, España
| | | | - I Da Cuña Carrera
- Facultad de Fisioterapia, Universidade de Vigo, Vigo, Pontevedra, España
| | - A Alonso Calvete
- Facultad de Fisioterapia, Universidade de Vigo, Vigo, Pontevedra, España
| |
Collapse
|
38
|
Yang G, Pang Z, Jamal Deen M, Dong M, Zhang YT, Lovell N, Rahmani AM. Homecare Robotic Systems for Healthcare 4.0: Visions and Enabling Technologies. IEEE J Biomed Health Inform 2020; 24:2535-2549. [PMID: 32340971 DOI: 10.1109/jbhi.2020.2990529] [Citation(s) in RCA: 46] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Powered by the technologies that have originated from manufacturing, the fourth revolution of healthcare technologies is happening (Healthcare 4.0). As an example of such revolution, new generation homecare robotic systems (HRS) based on the cyber-physical systems (CPS) with higher speed and more intelligent execution are emerging. In this article, the new visions and features of the CPS-based HRS are proposed. The latest progress in related enabling technologies is reviewed, including artificial intelligence, sensing fundamentals, materials and machines, cloud computing and communication, as well as motion capture and mapping. Finally, the future perspectives of the CPS-based HRS and the technical challenges faced in each technical area are discussed.
Collapse
|
39
|
Park EJ, Akbas T, Eckert-Erdheim A, Sloot LH, Nuckols RW, Orzel D, Schumm L, Ellis TD, Awad LN, Walsh CJ. A hinge-free, non-restrictive, lightweight tethered exosuit for knee extension assistance during walking. ACTA ACUST UNITED AC 2020; 2:165-175. [PMID: 33748694 DOI: 10.1109/tmrb.2020.2989321] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In individuals with motor impairments such as those post-stroke or with cerebral palsy, the function of the knee extensors may be affected during walking, resulting in decreased mobility. We have designed a lightweight, hinge-free wearable robot combining soft textile exosuit components with integrated rigid components, which assists knee extension when needed but is otherwise highly transparent to the wearer. The exosuit can apply a wide range of assistance profiles using a flexible multi-point reference trajectory generator. Additionally, we implemented a controller safety limit to address the risk of hyperextension stemming from the hinge-free design. The exosuit was evaluated on six healthy participants walking uphill and downhill on a treadmill at a 10° slope with a set of joint power-inspired assistance profiles. A comparison of sagittal plane joint angles between no exosuit and exosuit unpowered conditions validated the device transparency. With positive power assistance, we observed reduction in average positive knee biological power during uphill walking (left: 17.5 ± 3.21%, p = 0.005; right: 23.2 ± 3.54%, p = 0.008). These initial findings show promise for the assistive capability of the device and its potential to improve the quality of gait and increase mobility in clinical populations.
Collapse
Affiliation(s)
- Evelyn J Park
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Tunc Akbas
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Asa Eckert-Erdheim
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Lizeth H Sloot
- Institute for Computer Engineering (ZITI) at Heidelberg University, Heidelberg, Germany
| | - Richard W Nuckols
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Dorothy Orzel
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Lexine Schumm
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| | - Terry D Ellis
- Department of Physical Therapy & Athletic Training, Sargent College, Boston University, Boston, MA 02215 USA
| | - Louis N Awad
- Department of Physical Therapy & Athletic Training, Sargent College, Boston University, Boston, MA 02215 USA
| | - Conor J Walsh
- School of Engineering and Applied Sciences and the Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA 02138 USA
| |
Collapse
|
40
|
Zhang L, Liu G, Han B, Wang Z, Yan Y, Ma J, Wei P. Knee Joint Biomechanics in Physiological Conditions and How Pathologies Can Affect It: A Systematic Review. Appl Bionics Biomech 2020; 2020:7451683. [PMID: 32322301 PMCID: PMC7160724 DOI: 10.1155/2020/7451683] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 02/01/2020] [Indexed: 01/17/2023] Open
Abstract
The knee joint, as the main lower limb motor joint, is the most vulnerable and susceptible joint. The knee injuries considerably impact the normal living ability and mental health of patients. Understanding the biomechanics of a normal and diseased knee joint is in urgent need for designing knee assistive devices and optimizing a rehabilitation exercise program. In this paper, we systematically searched electronic databases (from 2000 to November 2019) including ScienceDirect, Web of Science, PubMed, Google Scholar, and IEEE/IET Electronic Library for potentially relevant articles. After duplicates were removed and inclusion criteria applied to the titles, abstracts, and full text, 138 articles remained for review. The selected articles were divided into two groups to be analyzed. Firstly, the real movement of a normal knee joint and the normal knee biomechanics of four kinds of daily motions in the sagittal and coronal planes, which include normal walking, running, stair climbing, and sit-to-stand, were discussed and analyzed. Secondly, an overview of the current knowledge on the movement biomechanical effects of common knee musculoskeletal disorders and knee neurological disorders were provided. Finally, a discussion of the existing problems in the current studies and some recommendation for future research were presented. In general, this review reveals that there is no clear assessment about the biomechanics of normal and diseased knee joints at the current state of the art. The biomechanics properties could be significantly affected by knee musculoskeletal or neurological disorders. Deeper understanding of the biomechanics of the normal and diseased knee joint will still be an urgent need in the future.
Collapse
Affiliation(s)
- Li Zhang
- Shaanxi Engineering Laboratory for Transmissions and Controls, Northwestern Polytechnical University, Xi'an 710072, China
| | - Geng Liu
- Shaanxi Engineering Laboratory for Transmissions and Controls, Northwestern Polytechnical University, Xi'an 710072, China
| | - Bing Han
- Shaanxi Engineering Laboratory for Transmissions and Controls, Northwestern Polytechnical University, Xi'an 710072, China
| | - Zhe Wang
- Shaanxi Engineering Laboratory for Transmissions and Controls, Northwestern Polytechnical University, Xi'an 710072, China
| | - Yuzhou Yan
- Shaanxi Engineering Laboratory for Transmissions and Controls, Northwestern Polytechnical University, Xi'an 710072, China
| | - Jianbing Ma
- Hong-Hui hospital, Xi'an Jiaotong University College of Medicine, Xi'an 710054, China
| | - Pingping Wei
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054, China
| |
Collapse
|
41
|
Chen J, Damiano DL, Lerner ZF, Bulea TC. Validating Model-Based Prediction Of Biological Knee Moment During Walking With An Exoskeleton in Crouch Gait: Potential Application for Exoskeleton Control. IEEE Int Conf Rehabil Robot 2020; 2019:778-783. [PMID: 31374725 DOI: 10.1109/icorr.2019.8779513] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Advanced control strategies that can adjust assistance based volitional effort from the user may be beneficial for deploying exoskeletons for overground gait training in ambulatory populations, such as children with cerebral palsy (CP). In this study, we evaluate the ability to predict biological knee moment during stance phase of walking with an exoskeleton in two children subjects with crouch gait from CP. The predictive model characterized the knee as a rotational spring with the addition of correction factors at knee extensor moment extrema to predict the instantaneous knee moment profile from the knee angle. Our model prediction performance was comparable to previous studies for weight acceptance (WA) and mid-stance (MS) phases in both assisted (Assist) and non-assisted (Zero) modes based on normalized root mean square error (RMSE), demonstrating the feasibility of joint moment estimation during exoskeleton walking. RMSE was highest in late stance phase, likely due to the non-linear knee stiffness exhibited during this phase in one participant. Overall, our results support real-time implementation of the joint moment prediction model for control of exoskeleton knee extension assistance in children with CP.
Collapse
|
42
|
Andrade RM, Sapienza S, Bonato P. Development of a "transparent operation mode" for a lower-limb exoskeleton designed for children with cerebral palsy. IEEE Int Conf Rehabil Robot 2019; 2019:512-517. [PMID: 31374681 DOI: 10.1109/icorr.2019.8779432] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Robot-assisted rehabilitation in children and young adults with Cerebral Palsy (CP) is expected to lead to neuroplasticity and reduce the burden of motor impairments. For a lower-limb exoskeleton to perform well in this context, it is essential that the robot be "transparent" to the user and produce torques only when voluntarily-generated motor outputs deviate significantly from the target trajectory. However, the development of transparent operation modes and assistance-as-need control schema are still open problems with several implementation challenges. This paper presents a theoretical approach and provides a discussion of the key issues pertinent to designing a transparent operation mode for a lower-limb exoskeleton suitable for children and young adults with CP. Based on the dynamics of exoskeletons as well as friction models and human-robot interaction models, we propose a control strategy aimed to minimize human-machine interaction forces when subjects generate motor outputs that match the target trajectory. The material is presented as a conceptual framework that can be generalized to other exoskeleton systems for overground walking.
Collapse
|
43
|
Yildirim MC, Kansizoglu AT, Emre S, Derman M, Coruk S, Soliman AF, Sendur P, Ugurlu B. Co-Ex: A Torque-Controllable Lower Body Exoskeleton for Dependable Human-Robot Co-existence. IEEE Int Conf Rehabil Robot 2019; 2019:605-610. [PMID: 31374697 DOI: 10.1109/icorr.2019.8779407] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
In this paper, we present our research study concerning the design and development of an exoskeleton that aims to provide 3D walking support with minimum number of actuators. Following a prior simulation study, the joint configuration was primarily determined. In order for the exoskeleton to possess advanced characteristics, the following design criteria were investigated: i) all the actuators (hip/knee/ankle) were deployed around the waist area to decrease leg weight and improve wearability, ii) custom-built series elastic actuators were used to power system for high fidelity torque-controllability, iii) 3D walking support is potentially enabled with reduced power requirements. As a result, we built the first actual prototype to experimentally verify the aforementioned design specifications. Furthermore, the preliminary torque control experiments indicated the viability of torque control.
Collapse
|
44
|
Computational modeling of neuromuscular response to swing-phase robotic knee extension assistance in cerebral palsy. J Biomech 2019; 87:142-149. [PMID: 30862380 DOI: 10.1016/j.jbiomech.2019.02.025] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Revised: 01/29/2019] [Accepted: 02/27/2019] [Indexed: 11/20/2022]
Abstract
Predicting subject-specific responses to exoskeleton assistance may aid in maximizing functional gait outcomes, such as achieving full knee-extension at foot contact in individuals with crouch gait from cerebral palsy (CP). The purpose of this study was to investigate the role of volitional and non-volitional muscle activity in subject-specific responses to knee extension assistance during walking with an exoskeleton. We developed a simulation framework to predict responses to exoskeleton torque by applying a stretch-reflex spasticity model with muscle excitations computed during unassisted walking. The framework was validated with data collected from six individuals with CP. Framework-predicted knee angle at terminal swing was within 4 ± 4° (mean ± sd) of the knee angle measured experimentally without the addition of spasticity. Kinematic responses in two-thirds of the participants could be accurately modeled using only underlying muscle activity and the applied exoskeleton torque; incorporating hamstring spasticity was necessary to recreate the measured kinematics to within 1 ± 1° in the remaining participants. We observed strong positive linear relationships between knee extension and exoskeleton assistance, and strong negative quadratic relationships between knee extension and spasticity. We utilized our framework to identify optimal torque profiles necessary to achieve full knee-extension at foot contact. An angular impulse of 0.061 ± 0.025 Nm·s·kg-1·deg-1 with 0.013 ± 0.002 Nm·kg-1·deg-1 of peak torque and 4.1 ± 1.9 W·kg-1·deg-1 peak mechanical power was required to achieve full knee extension (values normalized by knee excursion). This framework may aid the prescription of exoskeleton control strategies in pathologies with muscle spasticity. https://simtk.org/projects/knee-exo-pred/.
Collapse
|
45
|
Bulea TC, Lerner ZF, Damiano DL. Repeatability of EMG activity during exoskeleton assisted walking in children with cerebral palsy: implications for real time adaptable control. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:2801-2804. [PMID: 30440983 DOI: 10.1109/embc.2018.8512799] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Effective solutions for gait rehabilitation in children with cerebral palsy (CP) remain elusive. Wearable robotic exoskeletons offer the potential to greatly increase the dosage and intensity of gait training in this population, which may improve outcomes. We recently reported that a robotic exoskeleton significantly improved knee extension in children with crouch gait from CP. Longitudinal studies are necessary to fully understand long term biomechanical effects of exoskeleton gait training. Given that children's gait can change both as they develop and throughout their therapy, advanced control strategies which can adapt assistance over time may be beneficial. But, stride-to-stride variability makes it difficult to ascertain the effects of exoskeleton assistance and therefore complicates implementation of adaptable control algorithms. Here, we examine the use of the variance ratio (VR), a previously published measure, to assess the effect of exoskeleton assistance on knee extensor and flexor EMG variability in children with CP. Our results show that VR was significantly increased ($p<0.001)$ compared to baseline during walking with exoskeleton assistance. After five practice sessions, we found that VR was reduced though still greater than baseline levels. Given its sensitivity to exoskeleton assistance and ease of computation, VR may be a useful measure in the future for evaluating stride-to-stride variability in real time to inform algorithmic decision making for autonomous adaptable control.
Collapse
|
46
|
Wang J, Li X, Huang TH, Yu S, Li Y, Chen T, Carriero A, Oh-Park M, Su H. Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton. IEEE Robot Autom Lett 2018. [DOI: 10.1109/lra.2018.2864352] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
47
|
Lerner ZF, Damiano DL, Bulea TC. The Effects of Exoskeleton Assisted Knee Extension on Lower-Extremity Gait Kinematics, Kinetics, and Muscle Activity in Children with Cerebral Palsy. Sci Rep 2017; 7:13512. [PMID: 29044202 PMCID: PMC5647342 DOI: 10.1038/s41598-017-13554-2] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2017] [Accepted: 09/12/2017] [Indexed: 02/07/2023] Open
Abstract
Individuals with cerebral palsy often exhibit crouch gait, a debilitating and inefficient walking pattern marked by excessive knee flexion that worsens with age. To address the need for improved treatment, we sought to evaluate if providing external knee extension assistance could reduce the excessive burden placed on the knee extensor muscles as measured by knee moments. We evaluated a novel pediatric exoskeleton designed to provide appropriately-timed extensor torque to the knee joint during walking in a multi-week exploratory clinical study. Seven individuals (5-19 years) with mild-moderate crouch gait from cerebral palsy (GMFCS I-II) completed the study. For six participants, powered knee extension assistance favorably reduced the excessive stance-phase knee extensor moment present during crouch gait by a mean of 35% in early stance and 76% in late stance. Peak stance-phase knee and hip extension increased by 12° and 8°, respectively. Knee extensor muscle activity decreased slightly during exoskeleton-assisted walking compared to baseline, while knee flexor activity was elevated in some participants. These findings support the use of wearable exoskeletons for the management of crouch gait and provide insights into their future implementation.
Collapse
Affiliation(s)
- Zachary F Lerner
- Functional and Applied Biomechanics Section, Rehabilitation Medicine Department, National Institutes of Health, Bethesda, MD, USA
- Department of Mechanical Engineering, Northern Arizona University, Flagstaff, AZ, USA
| | - Diane L Damiano
- Functional and Applied Biomechanics Section, Rehabilitation Medicine Department, National Institutes of Health, Bethesda, MD, USA
| | - Thomas C Bulea
- Functional and Applied Biomechanics Section, Rehabilitation Medicine Department, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
48
|
Lerner ZF, Damiano DL, Bulea TC. A lower-extremity exoskeleton improves knee extension in children with crouch gait from cerebral palsy. Sci Transl Med 2017; 9:9/404/eaam9145. [PMID: 28835518 PMCID: PMC9993999 DOI: 10.1126/scitranslmed.aam9145] [Citation(s) in RCA: 65] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 04/13/2017] [Accepted: 07/18/2017] [Indexed: 12/20/2022]
Abstract
The ability to walk contributes considerably to physical health and overall well-being, particularly in children with motor disability, and is therefore prioritized as a rehabilitation goal. However, half of ambulatory children with cerebral palsy (CP), the most prevalent childhood movement disorder, cease to walk in adulthood. Robotic gait trainers have shown positive outcomes in initial studies, but these clinic-based systems are limited to short-term programs of insufficient length to maintain improved function in a lifelong disability such as CP. Sophisticated wearable exoskeletons are now available, but their utility in treating childhood movement disorders remains unknown. We evaluated an exoskeleton for the treatment of crouch (or flexed-knee) gait, one of the most debilitating pathologies in CP. We show that the exoskeleton reduced crouch in a cohort of ambulatory children with CP during overground walking. The exoskeleton was safe and well tolerated, and all children were able to walk independently with the device. Rather than guiding the lower limbs, the exoskeleton dynamically changed the posture by introducing bursts of knee extension assistance during discrete portions of the walking cycle, a perturbation that resulted in maintained or increased knee extensor muscle activity during exoskeleton use. Six of seven participants exhibited postural improvements equivalent to outcomes reported from invasive orthopedic surgery. We also demonstrate that improvements in crouch increased over the course of our multiweek exploratory trial. Together, these results provide evidence supporting the use of wearable exoskeletons as a treatment strategy to improve walking in children with CP.
Collapse
Affiliation(s)
- Zachary F Lerner
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD 20892, USA
| | - Diane L Damiano
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD 20892, USA
| | - Thomas C Bulea
- Rehabilitation Medicine Department, National Institutes of Health Clinical Center, Bethesda, MD 20892, USA.
| |
Collapse
|
49
|
Kang J, Martelli D, Vashista V, Martinez-Hernandez I, Kim H, Agrawal SK. Robot-driven downward pelvic pull to improve crouch gait in children with cerebral palsy. Sci Robot 2017; 2:2/8/eaan2634. [DOI: 10.1126/scirobotics.aan2634] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Accepted: 06/30/2017] [Indexed: 11/02/2022]
|
50
|
Lerner ZF, Damiano DL, Bulea TC. Relationship between assistive torque and knee biomechanics during exoskeleton walking in individuals with crouch gait. IEEE Int Conf Rehabil Robot 2017; 2017:491-497. [PMID: 28813868 PMCID: PMC10436701 DOI: 10.1109/icorr.2017.8009296] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Crouch or "flexed knee" gait is a pathological gait pattern affecting many individuals with cerebral palsy. One proposed method to alleviate crouch is to provide robotic assistance to knee extension during walking. The purpose of this study was to evaluate how the magnitude of knee extensor torque affects knee kinematics, kinetics, and muscle activity. Motion capture, ground reaction force and electromyography data were collected while four participants with crouch gait from cerebral palsy walked with assistance from a novel robotic exoskeleton on an instrumented treadmill. Different magnitudes of knee extensor torque were provided during the stance (range: 0.09-0.38 Nm/kg) and swing (range: 0.09-0.29 Nm/kg) phases of the gait cycle. Using a linear regression analysis, we found that greater torque from the exoskeleton was positively associated with increased knee extension (reduction in crouch) at foot contact and mid-stance, negatively associated with the biological knee extensor moment, and positively associated with knee flexor muscle activity. Determining the relationships between exoskeleton assistance and knee kinematics and kinetics will benefit the continued investigation of robotic treatment strategies for treating crouch gait. Our findings indicate the importance of properly tuned robotic control strategies for gait rehabilitation.
Collapse
|