1
|
Li M, Qi E, Xu G, Jin J, Zhao Q, Guo M, Liao W. A delayed matching task-based study on action sequence of motor imagery. Cogn Neurodyn 2024; 18:1593-1607. [PMID: 39104677 PMCID: PMC11297855 DOI: 10.1007/s11571-023-10030-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 09/28/2023] [Accepted: 10/23/2023] [Indexed: 08/07/2024] Open
Abstract
The way people imagine greatly affects performance of brain-computer interface (BCI) based on motion imagery (MI). Action sequence is a basic unit of imitation, learning, and memory for motor behavior. Whether it influences the MI-BCI is unknown, and how to manifest this influence is difficult since the MI is a spontaneous brain activity. To investigate the influence of the action sequence, this study proposes a novel paradigm named action sequences observing and delayed matching task to use images and videos to guide people to observe, match and reinforce the memory of sequence. Seven subjects' ERPs and MI performance are analyzed under four different levels of complexities or orders of the sequence. Results demonstrated that the action sequence in terms of complexity and sequence order significantly affects the MI. The complex action in positive order obtains stronger ERD/ERS and more pronounced MI feature distributions, and yields an MI classification accuracy that is 12.3% higher than complex action in negative order (p < 0.05). In addition, the ERP amplitudes derived from the supplementary motor area show a positive correlation to the MI. This study demonstrates a new perspective of improving imagery in the MI-BCI by considering the complexity and order of the action sequences, and provides a novel index for manifesting the MI performance by ERP.
Collapse
Affiliation(s)
- Mengfan Li
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300132 China
- Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, Tianjin, 300132 China
- Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, 300132 China
| | - Enming Qi
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300132 China
- Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, Tianjin, 300132 China
- Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, 300132 China
| | - Guizhi Xu
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300132 China
- Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, Tianjin, 300132 China
- Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, 300132 China
| | - Jing Jin
- Key Laboratory of Advanced Control and Optimization for Chemical Processes, East China, University of Science and Technology, Shanghai, 518063 China
- Shenzhen Research Institute of East China, University of Science and Technology, Shenzhen, 518063 China
| | - Qi Zhao
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300132 China
- Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, Tianjin, 300132 China
- Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, 300132 China
| | - Miaomiao Guo
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300132 China
- Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, Tianjin, 300132 China
- Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, Tianjin, 300132 China
| | - Wenzhe Liao
- School of Artificial Intelligence, Hebei University of Technology, Tianjin, 300132 China
| |
Collapse
|
2
|
Xu X, Fan X, Dong J, Zhang X, Song Z, Li W, Pu F. Event-Related EEG Desynchronization Reveals Enhanced Motor Imagery From the Third Person Perspective by Manipulating Sense of Body Ownership With Virtual Reality for Stroke Patients. IEEE Trans Neural Syst Rehabil Eng 2024; 32:1055-1067. [PMID: 38349835 DOI: 10.1109/tnsre.2024.3365587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024]
Abstract
Virtual reality (VR)-based rehabilitation training holds great potential for post-stroke motor recovery. Existing VR-based motor imagery (MI) paradigms mostly focus on the first-person perspective, and the benefit of the third-person perspective (3PP) remains to be further exploited. The 3PP is advantageous for movements involving the back or those with a large range because of its field coverage. Some movements are easier to imagine from the 3PP. However, the 3PP training efficiency may be unsatisfactory, which may be attributed to the difficulty encountered when generating a strong sense of ownership (SOO). In this work, we attempt to enhance a visual-guided 3PP MI in stroke patients by eliciting the SOO over a virtual avatar with VR. We propose to achieve this by inducing the so-called out-of-body experience (OBE), which is a full-body illusion (FBI) that people misperceive a 3PP virtual body as his/her own (i.e., generating the SOO to the virtual body). Electroencephalography signals of 13 stroke patients are recorded while MI of the affected upper limb is being performed. The proposed paradigm is evaluated by comparing event-related desynchronization (ERD) with a control paradigm without FBI induction. The results show that the proposed paradigm leads to a significantly larger ERD during MI, indicating a bilateral activation pattern consistent with that in previous studies. In conclusion, 3PP MI can be enhanced in stroke patients by eliciting the SOO through induction of the "OBE" FBI. This study offers more possibilities for virtual rehabilitation in stroke patients and can further facilitate VR application in rehabilitation.
Collapse
|
3
|
Tao T, Gao Y, Jia Y, Chen R, Li P, Xu G. A Multi-Channel Ensemble Method for Error-Related Potential Classification Using 2D EEG Images. SENSORS (BASEL, SWITZERLAND) 2023; 23:2863. [PMID: 36905065 PMCID: PMC10007400 DOI: 10.3390/s23052863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/19/2023] [Accepted: 03/02/2023] [Indexed: 06/18/2023]
Abstract
An error-related potential (ErrP) occurs when people's expectations are not consistent with the actual outcome. Accurately detecting ErrP when a human interacts with a BCI is the key to improving these BCI systems. In this paper, we propose a multi-channel method for error-related potential detection using a 2D convolutional neural network. Multiple channel classifiers are integrated to make final decisions. Specifically, every 1D EEG signal from the anterior cingulate cortex (ACC) is transformed into a 2D waveform image; then, a model named attention-based convolutional neural network (AT-CNN) is proposed to classify it. In addition, we propose a multi-channel ensemble approach to effectively integrate the decisions of each channel classifier. Our proposed ensemble approach can learn the nonlinear relationship between each channel and the label, which obtains 5.27% higher accuracy than the majority voting ensemble approach. We conduct a new experiment and validate our proposed method on a Monitoring Error-Related Potential dataset and our dataset. With the method proposed in this paper, the accuracy, sensitivity and specificity were 86.46%, 72.46% and 90.17%, respectively. The result shows that the AT-CNNs-2D proposed in this paper can effectively improve the accuracy of ErrP classification, and provides new ideas for the study of classification of ErrP brain-computer interfaces.
Collapse
Affiliation(s)
- Tangfei Tao
- Key Laboratory of Education Ministry for Modern Design & Rotor-Bearing System, Xi’an Jiaotong University, Xi’an 710049, China
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Yuxiang Gao
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Yaguang Jia
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Ruiquan Chen
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| | - Ping Li
- School of Foreign Studies, Xi’an Jiaotong University, Xi’an 710049, China
| | - Guanghua Xu
- School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an 710049, China
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, China
| |
Collapse
|
4
|
Li M, Zuo H, Zhou H, Xu G, Qi E. A study of action difference on motor imagery based on delayed matching posture task. J Neural Eng 2023; 20. [PMID: 36645915 DOI: 10.1088/1741-2552/acb386] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Accepted: 01/16/2023] [Indexed: 01/18/2023]
Abstract
Objective. Motor imagery (MI)-based brain-computer interfaces (BCIs) provide an additional control pathway for people by decoding the intention of action imagination. The way people imagine greatly affects MI-BCI performance. Action itself is one of the factors that influence the way people imagine. Whether the different actions cause a difference in the MI performance is unknown. What is more important is how to manifest this action difference in the process of imagery, which has the potential to guide people to use their individualized actions to imagine more effectively.Approach.To explore action differences, this study proposes a novel paradigm named as action observation based delayed matching posture task. Ten subjects are required to observe, memorize, match, and imagine three types of actions (cutting, grasping and writing) given by visual images or videos, to accomplish the phases of encoding, retrieval and reinforcement of MI. Event-related potential (ERP), MI features, and classification accuracy of the left or the right hand are used to evaluate the effect of the action difference on the MI difference.Main results.Action differences cause different feature distributions, resulting in that the accuracy with high event-related (de)synchronization (ERD/ERS) is 27.75% higher than the ones with low ERD/ERS (p< 0.05), which indicates that the action difference has impact on the MI difference and the BCI performance. In addition, significant differences in the ERP amplitudes exists among the three actions: the amplitude of P300-N200 potential reaches 9.28μV of grasping, 5.64μV and 5.25μV higher than the cutting and the writing, respectively (p< 0.05).Significance.The ERP amplitudes derived from the supplementary motor area shows positive correlation to the MI classification accuracy, implying that the ERP might be an index of the MI performance when the people is faced with action selection. This study demonstrates that the MI difference is related to the action difference, and can be manifested by the ERP, which is important for improving MI training by selecting suitable action; the relationship between the ERP and the MI provides a novel index to find the suitable action to set up an individualized BCI and improve the performance further.
Collapse
Affiliation(s)
- Mengfan Li
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Science and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, 300132 Tianjin, People's Republic of China
| | - Haoxin Zuo
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Science and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, 300132 Tianjin, People's Republic of China
| | - Huihui Zhou
- Peng Cheng Laboratory, 518000 Guangdong, People's Republic of China
| | - Guizhi Xu
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Science and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, 300132 Tianjin, People's Republic of China
| | - Enming Qi
- State Key Laboratory of Reliability and Intelligence of Electrical Equipment, School of Health Science and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Hebei Key Laboratory of Bioelectromagnetics and Neuroengineering, School of Health Sciences and Biomedical Engineering, Hebei University of Technology, 300132 Tianjin, People's Republic of China.,Tianjin Key Laboratory of Bioelectromagnetic Technology and Intelligent Health, Hebei University of Technology, 300132 Tianjin, People's Republic of China
| |
Collapse
|
5
|
A Review of Online Classification Performance in Motor Imagery-Based Brain–Computer Interfaces for Stroke Neurorehabilitation. SIGNALS 2023. [DOI: 10.3390/signals4010004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
Motor imagery (MI)-based brain–computer interfaces (BCI) have shown increased potential for the rehabilitation of stroke patients; nonetheless, their implementation in clinical practice has been restricted due to their low accuracy performance. To date, although a lot of research has been carried out in benchmarking and highlighting the most valuable classification algorithms in BCI configurations, most of them use offline data and are not from real BCI performance during the closed-loop (or online) sessions. Since rehabilitation training relies on the availability of an accurate feedback system, we surveyed articles of current and past EEG-based BCI frameworks who report the online classification of the movement of two upper limbs in both healthy volunteers and stroke patients. We found that the recently developed deep-learning methods do not outperform the traditional machine-learning algorithms. In addition, patients and healthy subjects exhibit similar classification accuracy in current BCI configurations. Lastly, in terms of neurofeedback modality, functional electrical stimulation (FES) yielded the best performance compared to non-FES systems.
Collapse
|
6
|
Wang X, Dai X, Liu Y, Chen X, Hu Q, Hu R, Li M. Motor imagery electroencephalogram classification algorithm based on joint features in the spatial and frequency domains and instance transfer. Front Hum Neurosci 2023; 17:1175399. [PMID: 37213929 PMCID: PMC10196205 DOI: 10.3389/fnhum.2023.1175399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 04/19/2023] [Indexed: 05/23/2023] Open
Abstract
Introduction Motor imagery electroencephalography (MI-EEG) has significant application value in the field of rehabilitation, and is a research hotspot in the brain-computer interface (BCI) field. Due to the small training sample size of MI-EEG of a single subject and the large individual differences among different subjects, existing classification models have low accuracy and poor generalization ability in MI classification tasks. Methods To solve this problem, this paper proposes a electroencephalography (EEG) joint feature classification algorithm based on instance transfer and ensemble learning. Firstly, the source domain and target domain data are preprocessed, and then common space mode (CSP) and power spectral density (PSD) are used to extract spatial and frequency domain features respectively, which are combined into EEG joint features. Finally, an ensemble learning algorithm based on kernel mean matching (KMM) and transfer learning adaptive boosting (TrAdaBoost) is used to classify MI-EEG. Results To validate the effectiveness of the algorithm, this paper compared and analyzed different algorithms on the BCI Competition IV Dataset 2a, and further verified the stability and effectiveness of the algorithm on the BCI Competition IV Dataset 2b. The experimental results show that the algorithm has an average accuracy of 91.5% and 83.7% on Dataset 2a and Dataset 2b, respectively, which is significantly better than other algorithms. Discussion The statement explains that the algorithm fully exploits EEG signals and enriches EEG features, improves the recognition of the MI signals, and provides a new approach to solving the above problem.
Collapse
Affiliation(s)
- Ximiao Wang
- Institute of Intelligent Systems and Control, Guangxi University of Science and Technology, Liuzhou, China
| | - Xisheng Dai
- Institute of Intelligent Systems and Control, Guangxi University of Science and Technology, Liuzhou, China
- *Correspondence: Xisheng Dai,
| | - Yu Liu
- School of Electronic Information and Automation, Guilin University of Aerospace Technology, Guilin, China
- Yu Liu,
| | - Xiangmeng Chen
- Department of Radiology, Jiangmen Central Hospital, Jiangmen, Guangdong, China
| | - Qinghui Hu
- School of Computer Science and Engineering, Guilin University of Aerospace Technology, Guilin, China
| | - Rongliang Hu
- Department of Rehabilitation Medicine, Jiangmen Central Hospital, Jiangmen, Guangdong, China
| | - Mingxin Li
- School of Computer Science and Engineering, Guilin University of Aerospace Technology, Guilin, China
| |
Collapse
|
7
|
Zhang X, Jiang Y, Hou W, Jiang N. Age-related differences in the transient and steady state responses to different visual stimuli. Front Aging Neurosci 2022; 14:1004188. [PMID: 36158550 PMCID: PMC9493465 DOI: 10.3389/fnagi.2022.1004188] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 08/22/2022] [Indexed: 11/13/2022] Open
Abstract
ObjectiveBrain-computer interface (BCI) has great potential in geriatric applications. However, most BCI studies in the literature used data from young population, and dedicated studies investigating the feasibility of BCIs among senior population are scarce. The current study, we analyzed the age-related differences in the transient electroencephalogram (EEG) response used in visual BCIs, i.e., visual evoked potential (VEP)/motion onset VEP (mVEP), and steady state-response, SSVEP/SSMVEP, between the younger group (age ranges from 22 to 30) and senior group (age ranges from 60 to 75).MethodsThe visual stimulations, including flicker, checkerboard, and action observation (AO), were designed with a periodic frequency. Videos of several hand movement, including grasping, dorsiflexion, the thumb opposition, and pinch were utilized to generate the AO stimuli. Eighteen senior and eighteen younger participants were enrolled in the experiments. Spectral-temporal characteristics of induced EEG were compared. Three EEG algorithms, canonical correlation analysis (CCA), task-related component analysis (TRCA), and extended CCA, were utilized to test the performance of the respective BCI systems.ResultsIn the transient response analysis, the motion checkerboard and AO stimuli were able to elicit prominent mVEP with a specific P1 peak and N2 valley, and the amplitudes of P1 elicited in the senior group were significantly higher than those in the younger group. In the steady-state analysis, SSVEP/SSMVEP could be clearly elicited in both groups. The CCA accuracies of SSVEPs/SSMVEPs in the senior group were slightly lower than those in the younger group in most cases. With extended CCA, the performance of both groups improved significantly. However, for AO targets, the improvement of the senior group (from 63.1 to 71.9%) was lower than that of the younger group (from 63.6 to 83.6%).ConclusionCompared with younger subjects, the amplitudes of P1 elicited by motion onset is significantly higher in the senior group, which might be a potential advantage for seniors if mVEP-based BCIs is used. This study also shows for the first time that AO-based BCI is feasible for the senior population. However, new algorithms for senior subjects, especially in identifying AO targets, are needed.
Collapse
Affiliation(s)
- Xin Zhang
- Bioengineering College, Chongqing University, Chongqing, China
- *Correspondence: Xin Zhang,
| | - Yi Jiang
- National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, China
- The Med-X Center for Manufacturing, Sichuan University, Chengdu, China
| | - Wensheng Hou
- Bioengineering College, Chongqing University, Chongqing, China
| | - Ning Jiang
- National Clinical Research Center for Geriatrics, West China Hospital, Sichuan University, Chengdu, China
- The Med-X Center for Manufacturing, Sichuan University, Chengdu, China
- Ning Jiang,
| |
Collapse
|