1
|
Chang H, Sun Y, Lu S, Lin D. A multistrategy differential evolution algorithm combined with Latin hypercube sampling applied to a brain-computer interface to improve the effect of node displacement. Sci Rep 2024; 14:20420. [PMID: 39227389 PMCID: PMC11372178 DOI: 10.1038/s41598-024-69222-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Accepted: 08/01/2024] [Indexed: 09/05/2024] Open
Abstract
Injection molding is a common plastic processing technique that allows melted plastic to be injected into a mold through pressure to form differently shaped plastic parts. In injection molding, in-mold electronics (IME) can include various circuit components, such as sensors, amplifiers, and filters. These components can be injected into the mold to form a whole within the melted plastic and can therefore be very easily integrated into the molded part. The brain-computer interface (BCI) is a direct connection pathway between a human or animal brain and an external device. Through BCIs, individuals can use their own brain signals to control these components, enabling more natural and intuitive interactions. In addition, brain-computer interfaces can also be used to assist in medical treatments, such as controlling prosthetic limbs or helping paralyzed patients regain mobility. Brain-computer interfaces can be realized in two ways: invasively and noninvasively, and in this paper, we adopt a noninvasive approach. First, a helmet model is designed according to head shape, and second, a printed circuit film is made to receive EEG signals and an IME injection mold for the helmet plastic parts. In the electronic film, conductive ink is printed to connect each component. However, improper parameterization during the injection molding process can lead to node displacements and residual stress changes in the molded part, which can damage the circuits in the electronic film and affect its performance. Therefore, in this paper, the use of the BCI molding process to ensure that the node displacement reaches the optimal value is studied. Second, the multistrategy differential evolutionary algorithm is used to optimize the injection molding parameters in the process of brain-computer interface formation. The relationship between the injection molding parameters and the actual target value is investigated through Latin hypercubic sampling, and the optimized parameters are compared with the target parameters to obtain the optimal parameter combination. Under the optimal parameters, the node displacement can be optimized from 0.585 to 0.027 mm, and the optimization rate can reach 95.38%. Ultimately, by detecting whether the voltage difference between the output inputs is within the permissible range, the reliability of the brain-computer interface after node displacement optimization can be evaluated.
Collapse
Affiliation(s)
- Hanjui Chang
- Department of Mechanical Engineering, College of Engineering, Shantou University, Shantou, 515063, China.
- Intelligent Manufacturing Key Laboratory of Ministry of Education, Shantou University, Shantou, 515063, China.
| | - Yue Sun
- Department of Mechanical Engineering, College of Engineering, Shantou University, Shantou, 515063, China
- Intelligent Manufacturing Key Laboratory of Ministry of Education, Shantou University, Shantou, 515063, China
| | - Shuzhou Lu
- Department of Mechanical Engineering, College of Engineering, Shantou University, Shantou, 515063, China
- Intelligent Manufacturing Key Laboratory of Ministry of Education, Shantou University, Shantou, 515063, China
| | - Daiyao Lin
- Department of Mechanical Engineering, College of Engineering, Shantou University, Shantou, 515063, China
- Intelligent Manufacturing Key Laboratory of Ministry of Education, Shantou University, Shantou, 515063, China
| |
Collapse
|
2
|
Liu R, Zhu G, Wu Z, Gan Y, Zhang J, Liu J, Wang L. Temporal interference stimulation targets deep primate brain. Neuroimage 2024; 291:120581. [PMID: 38508293 DOI: 10.1016/j.neuroimage.2024.120581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Revised: 03/10/2024] [Accepted: 03/17/2024] [Indexed: 03/22/2024] Open
Abstract
Temporal interference (TI) stimulation, a novel non-invasive stimulation strategy, has recently been shown to modulate neural activity in deep brain regions of living mice. Yet, it is uncertain if this method is applicable to larger brains and whether the electric field produced under traditional safety currents can penetrate deep regions as observed in mice. Despite recent model-based simulation studies offering positive evidence at both macro- and micro-scale levels, the absence of electrophysiological data from actual brains hinders comprehensive understanding and potential application of TI. This study aims to directly measure the spatiotemporal properties of the interfered electric field in the rhesus monkey brain and to validate the effects of TI on the human brain. Two monkeys were involved in the measurement, with implantation of several stereo-electroencephalography (SEEG) depth electrodes. TI stimulation was applied to anesthetized monkeys using two pairs of surface electrodes at differing stimulation parameters. Model-based simulations were also conducted and subsequently compared with actual recordings. Additionally, TI stimulation was administered to patients with motor disorders to validate its effects on motor symptoms. Through the integration of computational electric field simulation with empirical measurements, it was determined that the temporally interfering electric fields in the deep central regions are capable of attaining a magnitude sufficient to induce a subthreshold modulation effect on neural signals. Additionally, an improvement in movement disorders was observed as a result of TI stimulation. This study is the first to systematically measure the TI electric field in living non-human primates, offering empirical evidence that TI holds promise as a more focal and precise method for modulating neural activities in deep regions of a large brain. This advancement paves the way for future applications of TI in treating neuropsychiatric disorders.
Collapse
Affiliation(s)
- Ruobing Liu
- CAS Key Laboratory of Mental Health, Institute of Psychology, Beijing, PR China; Department of Psychology, University of Chinese Academy of Sciences, Beijing, PR China
| | - Guanyu Zhu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Zhengping Wu
- School of Innovations, Sanjiang University, Nanjing, PR China
| | - Yifei Gan
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Jianguo Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, PR China
| | - Jiali Liu
- CAS Key Laboratory of Mental Health, Institute of Psychology, Beijing, PR China; Department of Psychology, University of Chinese Academy of Sciences, Beijing, PR China
| | - Liang Wang
- CAS Key Laboratory of Mental Health, Institute of Psychology, Beijing, PR China; Department of Psychology, University of Chinese Academy of Sciences, Beijing, PR China.
| |
Collapse
|
3
|
Huang J, Zhang ZQ, Xiong B, Wang Q, Wan B, Li F, Yang P. Cross-Subject Transfer Method Based on Domain Generalization for Facilitating Calibration of SSVEP-Based BCIs. IEEE Trans Neural Syst Rehabil Eng 2023; 31:3307-3319. [PMID: 37578926 DOI: 10.1109/tnsre.2023.3305202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/16/2023]
Abstract
In steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs), various spatial filtering methods based on individual calibration data have been proposed to alleviate the interference of spontaneous activities in SSVEP signals for enhancing the SSVEP detection performance. However, the time-consuming calibration session would increase the visual fatigue of subjects and reduce the usability of the BCI system. The key idea of this study is to propose a cross-subject transfer method based on domain generalization, which transfers the domain-invariant spatial filters and templates learned from source subjects to the target subject with no access to the EEG data from the target subject. The transferred spatial filters and templates are obtained by maximizing the intra- and inter-subject correlations using the SSVEP data corresponding to the target and its neighboring stimuli. For SSVEP detection of the target subject, four types of correlation coefficients are calculated to construct the feature vector. Experimental results estimated with three SSVEP datasets show that the proposed cross-subject transfer method improves the SSVEP detection performance compared to state-of-art methods. The satisfactory results demonstrate that the proposed method provides an effective transfer learning strategy requiring no tedious data collection process for new users, holding the potential of promoting practical applications of SSVEP-based BCI.
Collapse
|
4
|
Chaddad A, Wu Y, Kateb R, Bouridane A. Electroencephalography Signal Processing: A Comprehensive Review and Analysis of Methods and Techniques. SENSORS (BASEL, SWITZERLAND) 2023; 23:6434. [PMID: 37514728 PMCID: PMC10385593 DOI: 10.3390/s23146434] [Citation(s) in RCA: 12] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 06/16/2023] [Accepted: 07/13/2023] [Indexed: 07/30/2023]
Abstract
The electroencephalography (EEG) signal is a noninvasive and complex signal that has numerous applications in biomedical fields, including sleep and the brain-computer interface. Given its complexity, researchers have proposed several advanced preprocessing and feature extraction methods to analyze EEG signals. In this study, we analyze a comprehensive review of numerous articles related to EEG signal processing. We searched the major scientific and engineering databases and summarized the results of our findings. Our survey encompassed the entire process of EEG signal processing, from acquisition and pretreatment (denoising) to feature extraction, classification, and application. We present a detailed discussion and comparison of various methods and techniques used for EEG signal processing. Additionally, we identify the current limitations of these techniques and analyze their future development trends. We conclude by offering some suggestions for future research in the field of EEG signal processing.
Collapse
Affiliation(s)
- Ahmad Chaddad
- School of Artificial Intelligence, Guilin University of Electronic Technology, Guilin 541004, China
- The Laboratory for Imagery, Vision and Artificial Intelligence, Ecole de Technologie Supérieure, Montreal, QC H3C 1K3, Canada
| | - Yihang Wu
- School of Artificial Intelligence, Guilin University of Electronic Technology, Guilin 541004, China
| | - Reem Kateb
- College of Computer Science and Engineering, Taibah University, Madinah 41477, Saudi Arabia
| | - Ahmed Bouridane
- Centre for Data Analytics and Cybersecurity, University of Sharjah, Sharjah 27272, United Arab Emirates
| |
Collapse
|
5
|
López-Larraz E, Escolano C, Robledo-Menéndez A, Morlas L, Alda A, Minguez J. A garment that measures brain activity: proof of concept of an EEG sensor layer fully implemented with smart textiles. Front Hum Neurosci 2023; 17:1135153. [PMID: 37305362 PMCID: PMC10250743 DOI: 10.3389/fnhum.2023.1135153] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2022] [Accepted: 04/20/2023] [Indexed: 06/13/2023] Open
Abstract
This paper presents the first garment capable of measuring brain activity with accuracy comparable to that of state-of-the art dry electroencephalogram (EEG) systems. The main innovation is an EEG sensor layer (i.e., the electrodes, the signal transmission, and the cap support) made entirely of threads, fabrics, and smart textiles, eliminating the need for metal or plastic materials. The garment is connected to a mobile EEG amplifier to complete the measurement system. As a first proof of concept, the new EEG system (Garment-EEG) was characterized with respect to a state-of-the-art Ag/AgCl dry-EEG system (Dry-EEG) over the forehead area of healthy participants in terms of: (1) skin-electrode impedance; (2) EEG activity; (3) artifacts; and (4) user ergonomics and comfort. The results show that the Garment-EEG system provides comparable recordings to Dry-EEG, but it is more susceptible to artifacts under adverse recording conditions due to poorer contact impedances. The textile-based sensor layer offers superior ergonomics and comfort compared to its metal-based counterpart. We provide the datasets recorded with Garment-EEG and Dry-EEG systems, making available the first open-access dataset of an EEG sensor layer built exclusively with textile materials. Achieving user acceptance is an obstacle in the field of neurotechnology. The introduction of EEG systems encapsulated in wearables has the potential to democratize neurotechnology and non-invasive brain-computer interfaces, as they are naturally accepted by people in their daily lives. Furthermore, supporting the EEG implementation in the textile industry may result in lower cost and less-polluting manufacturing processes compared to metal and plastic industries.
Collapse
|
6
|
Li G, Liu Y, Chen Y, Li M, Song J, Li K, Zhang Y, Hu L, Qi X, Wan X, Liu J, He Q, Zhou H. Polyvinyl alcohol/polyacrylamide double-network hydrogel-based semi-dry electrodes for robust electroencephalography recording at hairy scalp for noninvasive brain-computer interfaces. J Neural Eng 2023; 20. [PMID: 36863014 DOI: 10.1088/1741-2552/acc098] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2022] [Accepted: 03/02/2023] [Indexed: 03/04/2023]
Abstract
Objective.Reliable and user-friendly electrodes can continuously and real-time capture the electroencephalography (EEG) signals, which is essential for real-life brain-computer interfaces (BCIs). This study develops a flexible, durable, and low-contact-impedance polyvinyl alcohol/polyacrylamide double-network hydrogel (PVA/PAM DNH)-based semi-dry electrode for robust EEG recording at hairy scalp.Approach.The PVA/PAM DNHs are developed using a cyclic freeze-thaw strategy and used as a saline reservoir for semi-dry electrodes. The PVA/PAM DNHs steadily deliver trace amounts of saline onto the scalp, enabling low and stable electrode-scalp impedance. The hydrogel also conforms well to the wet scalp, stabilizing the electrode-scalp interface. The feasibility of the real-life BCIs is validated by conducting four classic BCI paradigms on 16 participants.Main results.The results show that the PVA/PAM DNHs with 7.5 wt% PVA achieve a satisfactory trade-off between the saline load-unloading capacity and the compressive strength. The proposed semi-dry electrode exhibits a low contact impedance (18 ± 8.9 kΩ at 10 Hz), a small offset potential (0.46 mV), and negligible potential drift (1.5 ± 0.4μV min-1). The temporal cross-correlation between the semi-dry and wet electrodes is 0.91, and the spectral coherence is higher than 0.90 at frequencies below 45 Hz. Furthermore, no significant differences are present in BCI classification accuracy between these two typical electrodes.Significance.Based on the durability, rapid setup, wear-comfort, and robust signals of the developed hydrogel, PVA/PAM DNH-based semi-dry electrodes are a promising alternative to wet electrodes in real-life BCIs.
Collapse
Affiliation(s)
- Guangli Li
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China.,Department of Neurology, Zhuzhou People's Hospital, Zhuzhou 412008, People's Republic of China
| | - Ying Liu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Yuwei Chen
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Mingzhe Li
- Wuhan Greentek Pty. Ltd, Wuhan 430074, People's Republic of China
| | - Jian Song
- Department of Neurosurgery, General Hospital of Central Command Theater of PLA, Wuhan 430012, People's Republic of China
| | - Kanghua Li
- Department of Neurology, Zhuzhou People's Hospital, Zhuzhou 412008, People's Republic of China
| | - Youmei Zhang
- Department of Child Psychology, The Third Hospital of Zhuzhou, Zhuzhou 412003, People's Republic of China
| | - Le Hu
- Wuhan Greentek Pty. Ltd, Wuhan 430074, People's Republic of China
| | - Xiaoman Qi
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Xuan Wan
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Jun Liu
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Quanguo He
- Hunan Key Laboratory of Biomedical Nanomaterials and Devices, College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou 412007, People's Republic of China
| | - Haihan Zhou
- Key Laboratory of Chemical Biology and Molecular Engineering of Ministry of Education, Institute of Molecular Science, Shanxi University, Taiyuan 030006, People's Republic of China
| |
Collapse
|
7
|
Ng CR, Fiedler P, Kuhlmann L, Liley D, Vasconcelos B, Fonseca C, Tamburro G, Comani S, Lui TKY, Tse CY, Warsito IF, Supriyanto E, Haueisen J. Multi-Center Evaluation of Gel-Based and Dry Multipin EEG Caps. SENSORS (BASEL, SWITZERLAND) 2022; 22:s22208079. [PMID: 36298430 PMCID: PMC9612204 DOI: 10.3390/s22208079] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2022] [Revised: 10/13/2022] [Accepted: 10/19/2022] [Indexed: 05/27/2023]
Abstract
Dry electrodes for electroencephalography (EEG) allow new fields of application, including telemedicine, mobile EEG, emergency EEG, and long-term repetitive measurements for research, neurofeedback, or brain-computer interfaces. Different dry electrode technologies have been proposed and validated in comparison to conventional gel-based electrodes. Most previous studies have been performed at a single center and by single operators. We conducted a multi-center and multi-operator study validating multipin dry electrodes to study the reproducibility and generalizability of their performance in different environments and for different operators. Moreover, we aimed to study the interrelation of operator experience, preparation time, and wearing comfort on the EEG signal quality. EEG acquisitions using dry and gel-based EEG caps were carried out in 6 different countries with 115 volunteers, recording electrode-skin impedances, resting state EEG and evoked activity. The dry cap showed average channel reliability of 81% but higher average impedances than the gel-based cap. However, the dry EEG caps required 62% less preparation time. No statistical differences were observed between the gel-based and dry EEG signal characteristics in all signal metrics. We conclude that the performance of the dry multipin electrodes is highly reproducible, whereas the primary influences on channel reliability and signal quality are operator skill and experience.
Collapse
Affiliation(s)
- Chuen Rue Ng
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Patrique Fiedler
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Levin Kuhlmann
- Faculty of Information Technology, Monash University, Building 63, 25 Exhibition Walk, Clayton, VIC 3800, Australia
| | - David Liley
- Brain and Psychological Sciences Research Centre, Swinburne University of Technology, P.O. Box 218, Hawthorn, VIC 3122, Australia
| | - Beatriz Vasconcelos
- Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
| | - Carlos Fonseca
- Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, s/n, 4200-465 Porto, Portugal
- Institute of Science and Innovation in Mechanical and Industrial Engineering, LAETA/INEGI, 4200-465 Porto, Portugal
| | - Gabriella Tamburro
- BIND-Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Via Luigi Polacchi, 11, 66100 Chieti, Italy
| | - Silvia Comani
- BIND-Behavioral Imaging and Neural Dynamics Center, University “G. d’Annunzio” of Chieti–Pescara, Via Luigi Polacchi, 11, 66100 Chieti, Italy
| | - Troby Ka-Yan Lui
- Department of Psychology, University of Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
- Center of Brain, Behavior and Metabolism, University of Lübeck, Marie-Curie-Straße, 23562 Lübeck, Germany
| | - Chun-Yu Tse
- Department of Social and Behavioural Sciences, City University of Hong Kong, Hong Kong, China
| | - Indhika Fauzhan Warsito
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| | - Eko Supriyanto
- IJN-UTM Cardiovascular Engineering Centre, School of Biomedical Engineering & Health Sciences, Universiti Teknologi Malaysia, Johor Bahru 81300, Malaysia
| | - Jens Haueisen
- Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98693 Ilmenau, Germany
| |
Collapse
|