1
|
Zhu P, Simon I, Kokalari I, Kohane DS, Rwei AY. Miniaturized therapeutic systems for ultrasound-modulated drug delivery to the central and peripheral nervous system. Adv Drug Deliv Rev 2024; 208:115275. [PMID: 38442747 PMCID: PMC11031353 DOI: 10.1016/j.addr.2024.115275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/19/2024] [Accepted: 03/01/2024] [Indexed: 03/07/2024]
Abstract
Ultrasound is a promising technology to address challenges in drug delivery, including limited drug penetration across physiological barriers and ineffective targeting. Here we provide an overview of the significant advances made in recent years in overcoming technical and pharmacological barriers using ultrasound-assisted drug delivery to the central and peripheral nervous system. We commence by exploring the fundamental principles of ultrasound physics and its interaction with tissue. The mechanisms of ultrasonic-enhanced drug delivery are examined, as well as the relevant tissue barriers. We highlight drug transport through such tissue barriers utilizing insonation alone, in combination with ultrasound contrast agents (e.g., microbubbles), and through innovative particulate drug delivery systems. Furthermore, we review advances in systems and devices for providing therapeutic ultrasound, as their practicality and accessibility are crucial for clinical application.
Collapse
Affiliation(s)
- Pancheng Zhu
- Department of Chemical Engineering, Delft University of Technology, 2629 HZ, Delft, the Netherlands; State Key Laboratory of Mechanics and Control of Aerospace Structures, Nanjing University of Aeronautics & Astronautics, 210016, Nanjing, China; Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China
| | - Ignasi Simon
- Department of Chemical Engineering, Delft University of Technology, 2629 HZ, Delft, the Netherlands
| | - Ida Kokalari
- Department of Chemical Engineering, Delft University of Technology, 2629 HZ, Delft, the Netherlands
| | - Daniel S Kohane
- Laboratory for Biomaterials and Drug Delivery, Department of Anesthesiology, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | - Alina Y Rwei
- Department of Chemical Engineering, Delft University of Technology, 2629 HZ, Delft, the Netherlands.
| |
Collapse
|
2
|
Riis Porsborg S, Krzyslak H, Pierchala MK, Trolé V, Astafiev K, Lou-Moeller R, Pennisi CP. Exploring the Potential of Ultrasound Therapy to Reduce Skin Scars: An In Vitro Study Using a Multi-Well Device Based on Printable Piezoelectric Transducers. Bioengineering (Basel) 2023; 10:bioengineering10050566. [PMID: 37237636 DOI: 10.3390/bioengineering10050566] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2023] [Revised: 04/24/2023] [Accepted: 05/04/2023] [Indexed: 05/28/2023] Open
Abstract
Excessive skin scarring affects over 100 million patients worldwide, with effects ranging from cosmetic to systemic problems, and an effective treatment is yet to be found. Ultrasound-based therapies have been used to treat a variety of skin disorders, but the exact mechanisms behind the observed effects are still unclear. The aim of this work was to demonstrate the potential of ultrasound for the treatment of abnormal scarring by developing a multi-well device based on printable piezoelectric material (PiezoPaint™). First, compatibility with cell cultures was evaluated using measurements of heat shock response and cell viability. Second, the multi-well device was used to treat human fibroblasts with ultrasound and quantify their proliferation, focal adhesions, and extracellular matrix (ECM) production. Ultrasound caused a significant reduction in fibroblast growth and ECM deposition without changes in cell viability or adhesion. The data suggest that these effects were mediated by nonthermal mechanisms. Interestingly, the overall results suggest that ultrasound treatment would a be beneficial therapy for scar reduction. In addition, it is expected that this device will be a useful tool for mapping the effects of ultrasound treatment on cultured cells.
Collapse
Affiliation(s)
- Simone Riis Porsborg
- Regenerative Medicine Group, Department of Health Science and Technology, Aalborg University, DK-9260 Gistrup, Denmark
| | - Hubert Krzyslak
- Regenerative Medicine Group, Department of Health Science and Technology, Aalborg University, DK-9260 Gistrup, Denmark
| | | | - Vincent Trolé
- CTS Ferroperm Piezoceramics, DK-3490 Kvistgaard, Denmark
| | | | | | - Cristian Pablo Pennisi
- Regenerative Medicine Group, Department of Health Science and Technology, Aalborg University, DK-9260 Gistrup, Denmark
| |
Collapse
|
3
|
Boerman O, Abedin Z, DiMaria-Ghalili RA, Weingarten MS, Neidrauer M, Lewin PA, Spiller KL. Gene expression changes in therapeutic ultrasound-treated venous leg ulcers. Front Med (Lausanne) 2023; 10:1144182. [PMID: 37064037 PMCID: PMC10098114 DOI: 10.3389/fmed.2023.1144182] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Accepted: 03/10/2023] [Indexed: 03/31/2023] Open
Abstract
Introduction Low-frequency, low-intensity ultrasound has been previously shown to promote healing of chronic wounds in humans, but mechanisms behind these effects are poorly understood. The purpose of this study was to evaluate gene expression differences in debrided human venous ulcer tissue from patients treated with low-frequency (20 kHz), low-intensity (100 mW/cm2) ultrasound compared to a sham treatment in an effort to better understand the potential biological mechanisms. Methods Debrided venous ulcer tissue was collected from 32 subjects one week after sham treatment or low-frequency, low-intensity ultrasound treatment. Of these samples, 7 samples (3 ultrasound treated and 4 sham treated) yielded sufficient quality total RNA for analysis by ultra-high multiplexed PCR (Ampliseq) and expression of more than 24,000 genes was analyzed. 477 genes were found to be significantly differentially expressed between the ultrasound and sham groups using cut-off values of p < 0.05 and fold change of 2. Results and Discussion The top differentially expressed genes included those involved in regulation of cell metabolism, proliferation, and immune cell signaling. Gene set enrichment analysis identified 20 significantly enriched gene sets from upregulated genes and 4 significantly enriched gene sets from downregulated genes. Most of the enriched gene sets from upregulated genes were related to cell-cell signaling pathways. The most significantly enriched gene set from downregulated genes was the inflammatory response gene set. These findings show that therapeutic ultrasound influences cellular behavior in chronic wounds as early as 1 week after application. Considering the well-known role of chronic inflammation in impairing wound healing in chronic wounds, these results suggest that a downregulation of inflammatory genes is a possible biological mechanism of ultrasound-mediated venous chronic wound healing. Such increased understanding may ultimately lead to the enhancement of ultrasound devices to accelerate chronic wound healing and increase patient quality of life.
Collapse
Affiliation(s)
- Olivia Boerman
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
- Biomedical Engineering, Bucknell University, Lewisburg, PA, United States
| | - Zahidur Abedin
- Division of Molecular Biology - Research Services, PrimBio Research Institute, Exton, PA, United States
| | - Rose Ann DiMaria-Ghalili
- Department of Nursing, College of Nursing and Health Professions, Drexel University, Philadelphia, PA, United States
| | - Michael S. Weingarten
- Department of Surgery, College of Medicine, Drexel University, Philadelphia, PA, United States
| | - Michael Neidrauer
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| | - Peter A. Lewin
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| | - Kara L. Spiller
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, United States
| |
Collapse
|
4
|
Salikhova T, Kushenova A, Akanov Z, Alkhojayev S, Nabiyev Y. The first experience of using a comprehensive detailed ultrasound examination of the foot in patients with diabetes mellitus. Foot (Edinb) 2023; 54:101981. [PMID: 36806119 DOI: 10.1016/j.foot.2023.101981] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 02/15/2023] [Accepted: 02/15/2023] [Indexed: 02/23/2023]
Abstract
INTRODUCTION Assessment of amputation risk has been discussed more than once in the management of patients with diabetes. Systemic inflammatory symptoms can serve as signs of an infectious process. However, not all patients show exhibit these symptoms in a timely manner. At the same time, a decrease in pain, tactile and temperature sensitivity fails as a part of the main assessment of risk factors in diabetes mellitus. METHODS Using examination methods and comparing with clinical experience and the results of other researchers, a pilot study was carried out to diagnose structural changes in the foot in patients with diabetes. Nested examinations were carried out in several stages, on the expert class medical ultrasonographic apparatus Siemens Acuson NX3. The methods of ultrasound diagnostics in the diabetic foot can be significantly helpful when using a scale of criteria and guidelines for the examination. CONCLUSION The main diagnostic criterion for determining the risks of developing a diabetic foot condition, could be a gradual transition from the phase of compaction of hyaline cartilage to the phase of synovitis, and then to the phase of development of bone tissue necrosis related to a part of the Charcot's foot. It leads to disruption of the musculoskeletal system of the foot, and atherosclerotic plaques and stenosis of the dorsalis pedis artery and first toe, which form a deterioration in the nutrition of the soft tissues of the foot with their necrosis.
Collapse
Affiliation(s)
- Tursunay Salikhova
- Department of Surgery, Asfendiyarov Kazakh National Medical University, 94 Tole bi Str., 050012 Almaty, Republic of Kazakhstan.
| | - Aigerim Kushenova
- Department of Laboratory and Functional Diagnostics, Medical Center "Salus", 283/1 Rozybakiev Str., 050060 Almaty, Republic of Kazakhstan
| | - Zhanay Akanov
- Department of Endocrinology, Medical Clinic AAA, 31 Nurlybaev Str., 050044 Almaty, Republic of Kazakhstan
| | - Saruarbek Alkhojayev
- Department of Traumatology and Orthopedics, Asfendiyarov Kazakh National Medical University, 94 Tole bi Str., 050012 Almaty, Republic of Kazakhstan
| | - Yergali Nabiyev
- Department of Traumatology and Orthopedics, Asfendiyarov Kazakh National Medical University, 94 Tole bi Str., 050012 Almaty, Republic of Kazakhstan
| |
Collapse
|
5
|
The Combination of Low-Frequency Ultrasound and Antibiotics Improves the Killing of In Vitro Staphylococcus aureus and Pseudomonas aeruginosa Biofilms. Antibiotics (Basel) 2022; 11:antibiotics11111494. [PMID: 36358151 PMCID: PMC9686553 DOI: 10.3390/antibiotics11111494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 10/19/2022] [Accepted: 10/25/2022] [Indexed: 11/17/2022] Open
Abstract
Due to an increase in underlying predisposing factors, chronic wounds have become an increasing burden on healthcare systems worldwide. Chronic infections often contain biofilm-forming bacteria, which are challenging to eradicate due to increased antibiotic tolerance; thus, new and improved therapeutic strategies are warranted. One such strategy is the combination of ultrasound and antibiotics. Therefore, this study aimed to investigate the combinatory effects of low-frequency (50 kHz) ultrasound delivered by specially designed ultrasound patches using flexible piezoelectric material, PiezoPaint™, in combination with antibiotics against biofilms with Staphylococcus aureus and Pseudomonas aeruginosa. The reduction in viable cells in S. aureus and P. aeruginosa biofilms was evaluated post-treatment with fusidic acid, clindamycin, ciprofloxacin, and colistin in combination with ultrasound treatment. Two-hour ultrasound treatment significantly increased the bactericidal effect of all four antibiotics, resulting in a 96−98% and 90−93% reduction in P. aeruginosa and S. aureus, respectively. In addition, an additive effect was observed when extending treatment to 4 h, resulting in >99% and 95−97% reduction in P. aeruginosa and S. aureus, respectively. These results contrasted the lack of effect observed when treating filter-biofilms with antibiotics alone. The combined effect of ultrasound and antibiotic treatment resulted in a synergistic effect, reducing the viability of the clinically relevant pathogens S. aureus and P. aeruginosa. The modularity of the specially designed patches intended for topical treatment holds promising applications as a supplement in chronic wound therapy. Further studies are warranted with clinically isolated strains and other clinically relevant antibiotics before proceeding to studies where safety and applicability are investigated.
Collapse
|
6
|
Pigatto AV, Giacobbo L, Lisibach A, Filho EML, Lima RG, Mueller JL. Design and calibration of a Tonpilz transducer for low frequency medical ultrasound tomography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:4611-4617. [PMID: 36086323 DOI: 10.1109/embc48229.2022.9872007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The design and performance of a transducer for low frequency ultrasound tomography is presented, motivated by recent research demonstrating that acoustic waves transmitting at frequencies between 10 kHz and 750 kHz penetrate the lungs and may be useful for thoracic imaging. An adaptation of the traditional Tonpilz design was developed, vibrational amplitude and electrical impedance were measured, and an optimal frequency was determined. The design is found to meet the desired mechanical, electrical, and safety specifications. Thus, it was considered a promising option for the target application of pulmonary imaging with ultrasound computed tomography between 50 and 200 kHz; highest efficiency achieved around 125 kHz and 156 kHz, and beam divergence of 40°.
Collapse
|
7
|
Non-contact electrical stimulation as an effective means to promote wound healing. Bioelectrochemistry 2022; 146:108108. [DOI: 10.1016/j.bioelechem.2022.108108] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 03/20/2022] [Accepted: 03/21/2022] [Indexed: 12/17/2022]
|
8
|
Mendonca LS, Minuzzi EV, Cipriani JPS, Radecker M, Bisogno FE. State-Space Model of an Electro-Mechanical-Acoustic Contactless Energy Transfer System Based on Multiphysics Networks. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:241-253. [PMID: 34406939 DOI: 10.1109/tuffc.2021.3105916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Contactless energy transfer systems are mainly divided into acoustic, inductive, capacitive, and optical, in which main applications are related to biomedical, wireless chargers, and sensors in metal enclosures. When solids are used as transfer media, ultrasound transducers based on piezoelectricity can be used for through-wall power transfer, which can be named as an electro-mechanical-acoustic contactless energy transfer system. This work presents a state-space model derived from a multiphysics network that includes all the multiphysical power conversion without separating the stages and including the real physical elements, like as the piezoelectric parameters and the geometry of the transfer media. The model is compared to the experimental response of the system and evaluated for different scenarios regarding transducers types and solid transfer media. An error analysis has shown that the maximum quadratic error between theoretical and experimental responses is 3.7%.
Collapse
|
9
|
Zhu P, Peng H, Mao L, Tian J. Piezoelectric Single Crystal Ultrasonic Transducer for Endoscopic Drug Release in Gastric Mucosa. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:952-960. [PMID: 32970594 DOI: 10.1109/tuffc.2020.3026320] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Modern advanced minimally invasive surgery has been implemented for most of the significant gastrointestinal diseases. However, patients with coagulopathy or unresectable tumors cannot be cured by current treatment methods. Moreover, other existing medical devices for targeted drug release are too large to be applied in gastric endoscope because the diameter of the biopsy channel is smaller than 3 mm. To address it, in this work, we developed a piezoelectric single crystal ultrasonic transducer (the diameter was only 2.2 mm and the mass was 0.076 g) to produce acoustic waves, which could promote the drug release in the designed position of the digestive tract through an endoscope. It exhibited the electromechanical coupling coefficient of 0.36 and the center frequency of 6.9 MHz with the -6-dB bandwidth of 23%. In in vitro sonophoresis experiment, the gastric mucosa permeability to Bovine Serum Albumin increased about 5.6 times when the ultrasonic transducer was activated at 40 [Formula: see text] and 60% duty ratio, proving that employment of this transducer could facilitate drug penetration in the gastric mucosa. Meanwhile, the permeability could be adjusted by tuning the duty ratio of the ultrasonic transducer. The corresponding sonophoresis mechanism was related to the acoustic streaming and the thermal effect produced by the transducer. In addition, the measured maximum power density was 128 mW/cm2 and the mechanical index of the ultrasonic transducer was 0.02. The results held a great implication for applications of the transducer for targeted drug release in the gastrointestinal tract.
Collapse
|
10
|
Las Heras K, Igartua M, Santos-Vizcaino E, Hernandez RM. Chronic wounds: Current status, available strategies and emerging therapeutic solutions. J Control Release 2020; 328:532-550. [DOI: 10.1016/j.jconrel.2020.09.039] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 09/17/2020] [Accepted: 09/18/2020] [Indexed: 02/07/2023]
|
11
|
Design and Analysis of Two Piezoelectric Cymbal Transducers with Metal Ring and Add Mass. SENSORS 2019; 19:s19010137. [PMID: 30609772 PMCID: PMC6338930 DOI: 10.3390/s19010137] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 12/26/2018] [Accepted: 12/27/2018] [Indexed: 12/01/2022]
Abstract
Based on traditional sandwich structure, two piezoelectric transducers were designed to meet the strict underwater application backgrounds such as high pressure, corrosion resistance, and high strength. Both transducers integrated most of previous researches while one transducer has a multilayer cavity structure which is different from the other structure and previous transducer structures. After a detailed simulation analysis of every structural parameter, key parameters were pointed out to have an obvious influence on its performance. Then, two models were constructed and compared with chosen sets of geometry parameters and manufacturing process, which can also provide a reference for low-frequency transducer design. The simulation results and experimental results of our transducers show a good consistency which indicates the cavity structure can reduce the resonance frequency.
Collapse
|