Feng T, Li J, Xie W, Cheng Q, Ta D. Adaptively multi-scale microstructure characterization of cancellous bone via Photoacoustic signal decomposition. ULTRASONICS 2024; 144:107407. [PMID: 39173274 DOI: 10.1016/j.ultras.2024.107407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Revised: 07/09/2024] [Accepted: 07/15/2024] [Indexed: 08/24/2024]
Abstract
Osteoporosis is a systemic disease with a high incidence in the elderly and seriously affects the quality of life of patients. Photoacoustic (PA) technology, which combines the advantages of light and ultrasound, can provide information about the physiological structure and chemical information of biological tissues in a non-invasive and non-radiative way. Due to the complex structural characteristics of bone tissue, PA signals generated by bone tissue are non-stationary and nonlinear. However, conventional PA signal processing methods are not effective for non-stationary signal processing. In this study, an empirical mode decomposition (EMD)-based Hilbert-Huang transform (HHT) PA signal analysis method, called HHT PA signal analysis (HPSA), was developed to assess the microstructure information of bone tissue, which is closely related to bone health. The feasibility of the HPSA method in bone health assessment was proven by numerical simulation and experimental studies on animal samples with different bone volume/total volume (BV/TV) and bone mineral densities. First, based on adaptive EMD, the different modes correlated with multi-scale information were mined from the PA signal, the correlations between different intrinsic mode function (IMF) modes and BV/TVs were analyzed, and the optimal mode for more efficient PA time-frequency analysis was selected. Second, multi-wavelength HPSA was used to assess the changes in the chemical components of the bone tissue. The results demonstrate that the HPSA method can distinguish bones with different BV/TVs and microstructure conditions adaptively with high efficiency. They further emphasize the potential of PA techniques in characterizing biological tissues in bones for early and rapid detection of bone diseases.
Collapse
Affiliation(s)
- Ting Feng
- Institute of Biomedical Engineering & Technology, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China.
| | - Jieshu Li
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Weiya Xie
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China; Qingdao innovation and development base, Harbin Engineering University, Qingdao 266000, China
| | - Qian Cheng
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China.
| | - Dean Ta
- Institute of Biomedical Engineering & Technology, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China; Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai 200433, China.
| |
Collapse
|
2
|
Song P, Andre M, Chitnis P, Xu S, Croy T, Wear K, Sikdar S. Clinical, Safety, and Engineering Perspectives on Wearable Ultrasound Technology: A Review. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:730-744. [PMID: 38090856 PMCID: PMC11416895 DOI: 10.1109/tuffc.2023.3342150] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/10/2024]
Abstract
Wearable ultrasound has the potential to become a disruptive technology enabling new applications not only in traditional clinical settings, but also in settings where ultrasound is not currently used. Understanding the basic engineering principles and limitations of wearable ultrasound is critical for clinicians, scientists, and engineers to advance potential applications and translate the technology from bench to bedside. Wearable ultrasound devices, especially monitoring devices, have the potential to apply acoustic energy to the body for far longer durations than conventional diagnostic ultrasound systems. Thus, bioeffects associated with prolonged acoustic exposure as well as skin health need to be carefully considered for wearable ultrasound devices. This article reviews emerging clinical applications, safety considerations, and future engineering and clinical research directions for wearable ultrasound technology.
Collapse
|
3
|
Wearing SC, Hooper SL, Langton CM, Keiner M, Horstmann T, Crevier-Denoix N, Pourcelot P. The Biomechanics of Musculoskeletal Tissues during Activities of Daily Living: Dynamic Assessment Using Quantitative Transmission-Mode Ultrasound Techniques. Healthcare (Basel) 2024; 12:1254. [PMID: 38998789 PMCID: PMC11241410 DOI: 10.3390/healthcare12131254] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 06/18/2024] [Accepted: 06/19/2024] [Indexed: 07/14/2024] Open
Abstract
The measurement of musculoskeletal tissue properties and loading patterns during physical activity is important for understanding the adaptation mechanisms of tissues such as bone, tendon, and muscle tissues, particularly with injury and repair. Although the properties and loading of these connective tissues have been quantified using direct measurement techniques, these methods are highly invasive and often prevent or interfere with normal activity patterns. Indirect biomechanical methods, such as estimates based on electromyography, ultrasound, and inverse dynamics, are used more widely but are known to yield different parameter values than direct measurements. Through a series of literature searches of electronic databases, including Pubmed, Embase, Web of Science, and IEEE Explore, this paper reviews current methods used for the in vivo measurement of human musculoskeletal tissue and describes the operating principals, application, and emerging research findings gained from the use of quantitative transmission-mode ultrasound measurement techniques to non-invasively characterize human bone, tendon, and muscle properties at rest and during activities of daily living. In contrast to standard ultrasound imaging approaches, these techniques assess the interaction between ultrasound compression waves and connective tissues to provide quantifiable parameters associated with the structure, instantaneous elastic modulus, and density of tissues. By taking advantage of the physical relationship between the axial velocity of ultrasound compression waves and the instantaneous modulus of the propagation material, these techniques can also be used to estimate the in vivo loading environment of relatively superficial soft connective tissues during sports and activities of daily living. This paper highlights key findings from clinical studies in which quantitative transmission-mode ultrasound has been used to measure the properties and loading of bone, tendon, and muscle tissue during common physical activities in healthy and pathological populations.
Collapse
Affiliation(s)
- Scott C. Wearing
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | - Sue L. Hooper
- School of Health, University of the Sunshine Coast, Sippy Downs, QLD 4556, Australia
| | - Christian M. Langton
- Griffith Centre of Rehabilitation Engineering, Griffith University, Southport, QLD 4222, Australia
| | - Michael Keiner
- Department of Exercise and Training Science, German University of Health and Sport, 85737 Ismaning, Bavaria, Germany
| | - Thomas Horstmann
- School of Medicine and Health, Technical University of Munich, 80992 Munich, Bavaria, Germany
| | | | - Philippe Pourcelot
- INRAE, BPLC Unit, Ecole Nationale Vétérinaire d’Alfort, 94700 Maisons-Alfort, France
| |
Collapse
|
4
|
Perolina E, Meissner S, Raos B, Harland B, Thakur S, Svirskis D. Translating ultrasound-mediated drug delivery technologies for CNS applications. Adv Drug Deliv Rev 2024; 208:115274. [PMID: 38452815 DOI: 10.1016/j.addr.2024.115274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/18/2024] [Accepted: 03/01/2024] [Indexed: 03/09/2024]
Abstract
Ultrasound enhances drug delivery into the central nervous system (CNS) by opening barriers between the blood and CNS and by triggering release of drugs from carriers. A key challenge in translating setups from in vitro to in vivo settings is achieving equivalent acoustic energy delivery. Multiple devices have now been demonstrated to focus ultrasound to the brain, with concepts emerging to also target the spinal cord. Clinical trials to date have used ultrasound to facilitate the opening of the blood-brain barrier. While most have focused on feasibility and safety considerations, therapeutic benefits are beginning to emerge. To advance translation of these technologies for CNS applications, researchers should standardise exposure protocol and fine-tune ultrasound parameters. Computational modelling should be increasingly used as a core component to develop both in vitro and in vivo setups for delivering accurate and reproducible ultrasound to the CNS. This field holds promise for transformative advancements in the management and pharmacological treatment of complex and challenging CNS disorders.
Collapse
Affiliation(s)
- Ederlyn Perolina
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand
| | - Svenja Meissner
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand
| | - Brad Raos
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand
| | - Bruce Harland
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand
| | - Sachin Thakur
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand
| | - Darren Svirskis
- School of Pharmacy, Faculty of Medical and Health Sciences, University of Auckland, 85 Park Road, Auckland 1023, New Zealand.
| |
Collapse
|
5
|
Jia Y, Han S, Li B, Liu C, Ta D. Backscatter measurement of cancellous bone using the ultrasound transit time spectroscopy. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2670-2686. [PMID: 38639562 DOI: 10.1121/10.0025689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 03/26/2024] [Indexed: 04/20/2024]
Abstract
Recently, ultrasound transit time spectroscopy (UTTS) was proposed as a promising method for bone quantitative ultrasound measurement. Studies have showed that UTTS could estimate the bone volume fraction and other trabecular bone structure in ultrasonic through-transmission measurements. The goal of this study was to explore the feasibility of UTTS to be adapted in ultrasonic backscatter measurement and further evaluate the performance of backscattered ultrasound transit time spectrum (BS-UTTS) in the measurement of cancellous bone density and structure. First, taking ultrasonic attenuation into account, the concept of BS-UTTS was verified on ultrasonic backscatter signals simulated from a set of scatterers with different positions and intensities. Then, in vitro backscatter measurements were performed on 26 bovine cancellous bone specimens. After a logarithmic compression of the BS-UTTS, a linear fitting of the log-compressed BS-UTTS versus ultrasonic propagated distance was performed and the slope and intercept of the fitted line for BS-UTTS were determined. The associations between BS-UTTS parameters and cancellous bone features were analyzed using simple linear regression. The results showed that the BS-UTTS could make an accurate deconvolution of the backscatter signal and predict the position and intensity of the simulated scatterers eliminating phase interference, even the simulated backscatter signal was with a relatively low signal-to-noise ratio. With varied positions and intensities of the scatterers, the slope of the fitted line for the log-compressed BS-UTTS versus ultrasonic propagated distance (i.e., slope of BS-UTTS for short) yield a high agreement (r2 = 99.84%-99.96%) with ultrasonic attenuation in simulated backscatter signal. Compared with the high-density cancellous bone, the low-density specimen showed more abundant backscatter impulse response in the BS-UTTS. The slope of BS-UTTS yield a significant correlation with bone mineral density (r = 0.87; p < 0.001), BV/TV (r = 0.87; p < 0.001), and cancellous bone microstructures (r up to 0.87; p < 0.05). The intercept of BS-UTTS was also significantly correlated with bone densities (r = -0.87; p < 0.001) and trabecular structures (|r|=0.43-0.80; p < 0.05). However, the slope of the BS-UTTS underestimated attenuation when measurements were performed experimentally. In addition, a significant non-linear relationship was observed between the measured attenuation and the attenuation estimated by the slope of the BS-UTTS. This study demonstrated that the UTTS method could be adapted to ultrasonic backscatter measurement of cancellous bone. The derived slope and intercept of BS-UTTS could be used in the measurement of bone density and microstructure. The backscattered ultrasound transit time spectroscopy might have potential in the diagnosis of osteoporosis in the clinic.
Collapse
Affiliation(s)
- Yan Jia
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Shuai Han
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Boyi Li
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
| | - Chengcheng Liu
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
| | - Dean Ta
- Institute of Biomedical Engineering and Technology, Academy for Engineering and Technology, Fudan University, Shanghai, 200433, China
- State Key Laboratory of Integrated Chips and Systems, Fudan University, Shanghai, 201203, China
- Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200438, China
| |
Collapse
|
6
|
Huang F, Tan R, Wang MW, Hu LC, Wang Z, Sun SD, Huang JW, Luo YW. Three‑dimensional finite element analysis: Anatomical splint fixation for Colles fractures. Exp Ther Med 2024; 27:98. [PMID: 38356671 PMCID: PMC10865454 DOI: 10.3892/etm.2024.12386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 12/21/2023] [Indexed: 02/16/2024] Open
Abstract
With the rapid development of digital research in clinical orthopedics, the efficacy and safety of splint fixation can be better evaluated through biomechanical analysis based on a three-dimensional (3D) finite element model. It is essential to address the current gap in understanding the biomechanical implications of anatomical splint fixation for Colles fractures. By employing advanced 3D finite element analysis, the present study aimed to provide a comprehensive evaluation, offering valuable insights that can contribute to enhancing the effectiveness of anatomical splint fixation in the clinical management of Colles fractures. The 3D finite element models of the forearm and hand were constructed using Mimics 15.0 according to data from computed tomography of a patient with a Colles fracture. After the validity of the model was verified, the corresponding material properties of the models were adjusted to simulate a Colles fracture. Subsequently, the reduction functions, such as radial inclination and ulnar deviation, of the simulated fracture were completed and the mechanical changes of the tissues surrounding the fracture were calculated. Anatomical splints were then placed on the surfaces of the 3D finite element models of Colles fractures at various positions to analyze the changes in the stress cloud diagram, such as for the soft tissue and anatomical splints. In the present study, the constructed 3D finite element models were accurate and valid. The maximum stress of the anatomical splints and soft tissues was 2.346 and 0.106 MPa in pronation, 1.780 and 0.069 MPa in median rotation and 3.045 and 0.057 MPa in supination, respectively. Splint stress reached the highest level in supination and soft tissue stress achieved the highest level in pronation. The peak of splint stress occurred during supination, which contrasts to the peak of soft tissue stress observed in pronation, suggesting splint fixation median rotation can effectively avoid compression of the local soft tissue.
Collapse
Affiliation(s)
- Fei Huang
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Rui Tan
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Meng-Wei Wang
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Liu-Chao Hu
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Zhi Wang
- Department of Operating Room, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Shi-Dong Sun
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Jie-Wen Huang
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| | - Yi-Wen Luo
- Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China
| |
Collapse
|
7
|
Xu Z, Locke CS, Morris R, Jamison D, Kozloff KM, Wang X. Development of a semi-anthropomorphic photoacoustic calcaneus phantom based on nano computed tomography and stereolithography 3D printing. J Orthop Res 2024; 42:647-660. [PMID: 37804209 PMCID: PMC10932887 DOI: 10.1002/jor.25702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 06/28/2023] [Accepted: 10/05/2023] [Indexed: 10/09/2023]
Abstract
Osteoporosis is a major public health threat with significant physical, psychosocial, and financial consequences. The calcaneus bone has been used as a measurement site for risk prediction of osteoporosis by noninvasive quantitative ultrasound (QUS). By adding optical contrast to QUS, our previous studies indicate that a combination of photoacoustic (PA) and QUS, that is, PAQUS, provides a novel opportunity to assess the health of human calcaneus. Calibration of the PAQUS system is crucial to realize quantitative and repeatable measurements of the calcaneus. Therefore, a phantom which simulates the optical, ultrasound, and architectural properties of the human calcaneus, for PAQUS system calibration, is required. Additionally, a controllable phantom offers researchers a versatile framework for developing versatile structures, allowing more controlled assessment of how varying bone structures cause defined alterations in PA and QUS signals. In this work, we present the first semi-anthropomorphic calcaneus phantom for PAQUS. The phantom was developed based on nano computed-tomography (nano-CT) and stereolithography 3D printing, aiming to maximize accuracy in the approximation of both trabecular and cortical bone microstructures. Compared with the original digital input calcaneus model from a human cadaveric donor, the printed model achieved accuracies of 71.15% in total structure and 87.21% in bone volume fraction. Inorganic materials including synthetic blood, mineral oil, intralipid, and agar gel were used to model the substitutes of bone marrow and soft tissue, filling and covering the calcaneus phantom. The ultrasound and optical properties of this phantom were measured, and the results were consistent with those measured by a commercialized device and from previous in vivo studies. In addition, a short-term stability test was conducted for this phantom, demonstrating that the optical and ultrasound properties of the phantom were stable without significant variation over 1 month. This semi-anthropomorphic calcaneus phantom shows structural, ultrasound, and optical properties similar to those from a human calcaneus in vivo and, thereby, can serve as an effective source for equipment calibration and the comprehensive study of human patients.
Collapse
Affiliation(s)
- Zhanpeng Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Conor S. Locke
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | - DeAndre Jamison
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Kenneth M. Kozloff
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
- Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
8
|
Bi D, Shi L, Li B, Li Y, Liu C, Le LH, Luo J, Wang S, Ta D. The Protocol of Ultrasonic Backscatter Measurements of Musculoskeletal Properties. PHENOMICS (CHAM, SWITZERLAND) 2024; 4:72-80. [PMID: 38605911 PMCID: PMC11004104 DOI: 10.1007/s43657-023-00122-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2022] [Revised: 07/15/2023] [Accepted: 07/19/2023] [Indexed: 04/13/2024]
Abstract
This study aims to introduce the protocol for ultrasonic backscatter measurements of musculoskeletal properties based on a novel ultrasonic backscatter bone diagnostic (UBBD) instrument. Dual-energy X-ray absorptiometry (DXA) can be adopted to measure bone mineral density (BMD) in the hip, spine, legs and the whole body. The muscle and fat mass in the legs and the whole body can be also calculated by DXA body composition analysis. Based on the proposed protocol for backscatter measurements by UBBD, ultrasonic backscatter signals can be measured in vivo, deriving three backscatter parameters [apparent integral backscatter (AIB), backscatter signal peak amplitude (BSPA) and the corresponding arrival time (BSPT)]. AIB may provide important diagnostic information about bone properties. BSPA and BSPT may be important indicators of muscle and fat properties. The standardized backscatter measurement protocol of the UBBD instrument may have the potential to evaluate musculoskeletal characteristics, providing help for promoting the application of the backscatter technique in the clinical diagnosis of musculoskeletal disorders (MSDs), such as osteoporosis and muscular atrophy.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Lingwei Shi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
| | - Lawrence H. Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, T6G2B7 Canada
| | - Jingchun Luo
- Human Phenome Institute, Fudan University, Shanghai, 201203 China
| | - Sijia Wang
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, 200031 China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 2005 Songhu Road, Yangpu District, Shanghai, 200438 China
- Academy for Engineering and Technology, Fudan University, Shanghai, 200433 China
- Human Phenome Institute, Fudan University, Shanghai, 201203 China
| |
Collapse
|
9
|
Xu W, Xie W, Yu D, Sun H, Gu Y, Tao X, Qian M, Cheng L, Wang H, Cheng Q. Theoretical and experimental study of attenuation in cancellous bone. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:S11526. [PMID: 38505736 PMCID: PMC10949015 DOI: 10.1117/1.jbo.29.s1.s11526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 02/16/2024] [Accepted: 02/19/2024] [Indexed: 03/21/2024]
Abstract
Significance Photoacoustic (PA) technology shows great potential for bone assessment. However, the PA signals in cancellous bone are complex due to its complex composition and porous structure, making such signals challenging to apply directly in bone analysis. Aim We introduce a photoacoustic differential attenuation spectrum (PA-DAS) method to separate the contribution of the acoustic propagation path to the PA signal from that of the source, and theoretically and experimentally investigate the propagation attenuation characteristics of cancellous bone. Approach We modified Biot's theory by accounting for the high frequency and viscosity. In parallel with the rabbit osteoporosis model, we build an experimental PA-DAS system featuring an eccentric excitation differential detection mechanism. Moreover, we extract a PA-DAS quantization parameter-slope-to quantify the attenuation of high- and low-frequency components. Results The results show that the porosity of cancellous bone can be evaluated by fast longitude wave attenuation at different frequencies and the PA-DAS slope of the osteoporotic group is significantly lower compared with the normal group (**p < 0.01 ). Conclusions Findings demonstrate that PA-DAS effectively differentiates osteoporotic bone from healthy bone, facilitating quantitative assessment of bone mineral density, and osteoporosis diagnosis.
Collapse
Affiliation(s)
- Wenyi Xu
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Weiya Xie
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Dong Yu
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Haohan Sun
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Ying Gu
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Xingliang Tao
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Menglu Qian
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Liming Cheng
- Tongji University, Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration of Ministry of Education, Shanghai, China
| | - Hao Wang
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
| | - Qian Cheng
- Tongji University, Institute of Acoustics, School of Physics Science and Engineering, Shanghai, China
- National Key Laboratory of Autonomous Intelligent Unmanned Systems, Shanghai, China
- Frontiers Science Center for Intelligent Autonomous Systems, Ministry of Education, Shanghai, China
| |
Collapse
|
10
|
Jiang C, Li B, Xie L, Liu C, Xu K, Zhan Y, Ta D. Ray theory-based compounded plane wave ultrasound imaging for aberration corrected transcranial imaging: Phantom experiments and simulations. ULTRASONICS 2023; 135:107124. [PMID: 37541030 DOI: 10.1016/j.ultras.2023.107124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Revised: 07/25/2023] [Accepted: 07/26/2023] [Indexed: 08/06/2023]
Abstract
Compounded plane wave imaging (CPWI) allows high-frame-rate measurement and has been one of the most promising modalities for real-time brain imaging. However, ultrasonic brain imaging using the CPWI modality is usually performed with a worn thin or removal of the skull layer. Otherwise, the skull layer is expected to distort the ultrasonic wavefronts and significantly decrease intracranial imaging quality. The motivation of this study is to investigate a CPWI method for transcranial brain imaging with the skull layer. A coordinate transformation ray-tracing (CTRT) approach was proposed to track the distorted ultrasonic wavefronts and calculate the time delays for the ultrasound plane wave passing through the skull layer. With an accurate correction for the time delays in beamforming, the CTRT-based CPWI could achieve high-quality intracranial images with the presence of skulls. The proposed CTRT-based CPWI method was verified using a simplified three-layer transcranial model. The full-wave simulation demonstrated that CTRT could accurately (i.e., relative percentage error less than0.18%) track the distorted transmitting wavefront through skull. Compared with the CPWI without aberration correction, the CTRT-based CPWI provided high-quality intracranial imaging and could accurately localize intracranial point scatterers; specifically, positioning error decreases from 0.5 mm to 0.1 mm on average in the axial direction and from 0.7 mm to 0.1 mm on average in the lateral direction. As the compounded angles increased in the CTRT-based CPWI, the contrast improved by 16.2 dB on average for the region of interest, and the array performance indicator (representing resolution) decreased by 4.0 on average for the intracranial point scatterers. The CTRT is of low computational cost compared with full wave simulation. This study suggested that the proposed CTRT-based CPWI might have the potential for real-time and non-invasive transcranial aberration-corrected imaging.
Collapse
Affiliation(s)
- Chen Jiang
- Micro-nano System Center, School of Information Science and Technology, Fudan University, 200438, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, 200433, Shanghai, China
| | - Linru Xie
- Academy for Engineering and Technology, Fudan University, 200433, Shanghai, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, 200433, Shanghai, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, 201203, Shanghai, China
| | - Kailiang Xu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 200438, Shanghai, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, 201203, Shanghai, China.
| | - Yiqiang Zhan
- Micro-nano System Center, School of Information Science and Technology, Fudan University, 200438, Shanghai, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, 200438, Shanghai, China; State Key Laboratory of Integrated Chips and Systems, Fudan University, 201203, Shanghai, China.
| |
Collapse
|
11
|
Hoffmeister BK, Lawler BC, Viano AM, Mobley J. Effect of transducer position on ultrasonic backscatter measurements of cancellous bone. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:2858-2868. [PMID: 37930178 DOI: 10.1121/10.0022324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 10/16/2023] [Indexed: 11/07/2023]
Abstract
Ultrasonic backscatter techniques are being developed to detect changes in bone caused by osteoporosis and other diseases. Backscatter measurements performed at peripheral skeletal sites such as the heel may place the interrogated region of bone tissue in the acoustic near field of the transducer. The purpose of this study is to investigate how measurements in the near field affect backscatter parameters used for ultrasonic bone assessment. Ultrasonic measurements were performed in a water tank using a planar 2.25 MHz transducer. Signals were acquired for five transducer-specimen distances: N/4, N/2, 3 N/4, N, and 5 N/4, where N is the near-field distance, a location that represents the transition from the near field to far field. Five backscatter parameters previously identified as potentially useful for ultrasonic bone assessment purposes were measured: apparent integrated backscatter, frequency slope of apparent backscatter (FSAB), frequency intercept of apparent backscatter, normalized mean of the backscatter difference, and backscatter amplitude decay constant. All five parameters depended on transducer-specimen distance to varying degrees with FSAB exhibiting the greatest dependence on distance. These results suggest that laboratory studies of bone should evaluate the performance of backscatter parameters using transducer-specimen distances that may be encountered clinically including distances where the ultrasonically interrogated region is in the near field of the transducer.
Collapse
Affiliation(s)
| | - Blake C Lawler
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Ann M Viano
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Joel Mobley
- Department of Physics and Astronomy/National Center for Physical Acoustics, University of Mississippi, University, Mississippi 38677, USA
| |
Collapse
|
12
|
Zhou C, Xu K, Ta D. Frequency-domain full-waveform inversion-based musculoskeletal ultrasound computed tomography. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 154:279-294. [PMID: 37449785 DOI: 10.1121/10.0020151] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2023] [Accepted: 06/27/2023] [Indexed: 07/18/2023]
Abstract
Recently, full-waveform inversion (FWI) has become a promising tool for ultrasound computed tomography (USCT). However, as a computationally intensive technique, FWI suffers from computational burden, especially in conventional time-domain full-waveform inversion (TDFWI). On the contrary, frequency-domain full-waveform inversion (FDFWI) provides a relatively high computational efficiency as the propagation of discrete frequencies is much cheaper than full time-domain modeling. FDFWI has already been applied in soft tissue imaging, such as breast, but for the musculoskeletal model with high impedance contrast between hard and soft tissues, there is still a lack of an effective source estimation method. In this paper, a water-referenced data calibration method is proposed to address the source estimation challenge in the presence of bones, which achieves consistency between the measured and simulated data before the FDFWI procedure. To avoid the cycle-skipping local minimum effect and facilitate the algorithm convergence, a starting frequency criterion for musculoskeletal FDFWI is further proposed. The feasibility of the proposed method is demonstrated by numerical studies on retrieving the anatomies of the leg models and different musculoskeletal lesions. The study extends the advanced FDFWI method to the musculoskeletal system and provides an alternative solution for musculoskeletal USCT imaging with high computational efficiency.
Collapse
Affiliation(s)
- Chenchen Zhou
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Kailiang Xu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| |
Collapse
|
13
|
Sadoughi S, Bevill G, Morgan EF, Palepu V, Keaveny TM, Wear KA. Biomechanical structure-function relations for human trabecular bone - comparison of calcaneus, femoral neck, greater trochanter, proximal tibia, and vertebra. Comput Methods Biomech Biomed Engin 2023; 26:508-516. [PMID: 35579530 PMCID: PMC9669279 DOI: 10.1080/10255842.2022.2069465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Revised: 04/04/2022] [Accepted: 04/20/2022] [Indexed: 11/03/2022]
Abstract
MicroCT-based finite element models were used to compute power law relations for uniaxial compressive yield stress versus bone volume fraction for 78 cores of human trabecular bone from five anatomic sites. The leading coefficient of the power law for calcaneus differed from those for most of the other sites (p < 0.05). However, after normalizing by site-specific mean values, neither the leading coefficient (p > 0.5) nor exponent (p > 0.5) differed among sites, suggesting that a given percentage deviation from mean bone volume fraction has the same mechanical consequence for all sites investigated. These findings help explain the success of calcaneal x-ray and ultrasound measurements for predicting hip fracture risk.
Collapse
Affiliation(s)
- Saghi Sadoughi
- Department of Mechanical Engineering, University of California, Berkeley, CA
| | - Grant Bevill
- Mechanical Engineering Department, University of North Florida, Jacksonville, FL
| | - Elise F Morgan
- Departments of Mechanical Engineering and Biomedical Engineering, Boston University, Boston, MA
| | - Vivek Palepu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California, Berkeley, CA
- Department of Bioengineering, University of California, Berkeley, CA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
| |
Collapse
|
14
|
Feng T, Zhu Y, Gao X, Xie W, Ma H, Cheng L, Ta D, Cheng Q. Nakagami statistics-based photoacoustic spectroscopy used for label-free assessment of bone tissue. OPTICS LETTERS 2023; 48:656-659. [PMID: 36723556 DOI: 10.1364/ol.477011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 11/29/2022] [Indexed: 06/18/2023]
Abstract
Quick identification of abnormal molecular metabolism of bone tissues is challenging. Photoacoustic (PA) spectroscopy techniques have great potential in molecular imaging. However, most of them are amplitude-dependent and easily affected by the light deposition, especially for bone tissues with high optical scattering. In this Letter, we propose a Nakagami statistics-based PA spectroscopy (NSPS) method for characterizing molecules in bone tissues. We indicate that the NSPS curve can intelligently identify changes in the content of molecules in bone tissues, with a high disturbance-resisting ability. The NSPS has remarkable potential for use in the early and rapid detection of bone diseases.
Collapse
|
15
|
Bi D, Shi L, Liu C, Li B, Li Y, Le LH, Luo J, Wang S, Ta D. Ultrasonic Through-Transmission Measurements of Human Musculoskeletal and Fat Properties. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:347-355. [PMID: 36266143 DOI: 10.1016/j.ultrasmedbio.2022.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/07/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
The study described here was aimed at investigating the feasibility of using the ultrasonic through-transmission technique to estimate human musculoskeletal and fat properties. Five hundred eighty-two volunteers were assessed by dual-energy X-ray absorptiometry (DXA) and ultrasonic transmission techniques. Bone mineral density (BMD), muscle and fat mass were measured for both legs and the whole body. Hip BMD and spine BMD were also measured. Ultrasonic transmission measurements were performed on the heel, and the measured parameters were broadband ultrasound attenuation (BUA), speed of sound (SOS), ultrasonic stiffness index (SI), T-score and Z-score, which were significantly correlated with all measured BMDs. The optimal correlation was observed between SI and left-leg BMD (p < 0.001) before and after adjustment for age, sex and body mass index (BMI). The linear and partial correlation analyses revealed that BUA and SOS were closely associated with muscle and fat mass, respectively. Multiple regressions revealed that muscle and fat mass significantly contributed to the prediction of transmission parameters, explaining up to 17.83% (p < 0.001) variance independently of BMD. The results suggest that the ultrasonic through-transmission technique could help in the clinical diagnosis of skeletal and muscular system diseases.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lingwei Shi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Lawrence H Le
- Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton, Alberta, Canada
| | - Jingchun Luo
- Human Phenome Institute, Fudan University, Shanghai, China
| | - Sijia Wang
- Shanghai Institute of Nutrition and Health, Chinese Academy of Sciences, Shanghai, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China; Human Phenome Institute, Fudan University, Shanghai, China.
| |
Collapse
|
16
|
Zuo N, Dong S, Li D, Zhang N, Wang X. Inspection depth of uterine lumen measured by transvaginal ultrasound is associated with the success of IVF: a prospective longitudinal cohort study in China. J Assist Reprod Genet 2022; 39:2777-2787. [PMID: 36427172 PMCID: PMC9790830 DOI: 10.1007/s10815-022-02657-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 11/04/2022] [Indexed: 11/27/2022] Open
Abstract
OBJECTIVE To measure the inspection depth of uterine lumen by transvaginal ultrasound and assess the association between the inspection depth and pregnancy outcomes in IVF-ET. METHODS This prospective longitudinal cohort study was conducted from June 2018 to December 2020. We enrolled patients aged 20-45 years who underwent frozen embryo transfer cycle. We calculated the average distance from the uterine lumen to the ultrasound probe (inspection depth) using transvaginal ultrasonography and divided the entire cohort into four groups according to the quartiles of the overall inspection depth distribution. The chi-square test was used to compare the pregnancy outcomes of the four groups. Univariate and multivariate regression analyses were performed to assess the association between the inspection depth and pregnancy outcomes. RESULTS Seven hundred forty-two patients were finally enrolled, and they were grouped according to the inspection depth quartiles. There were significant decrease in the clinical pregnancy, implantation, and live birth rates among the four groups (P < 0.05); however, there was no significant difference in the miscarriage rate. Multivariable logistic regression analysis with the inspection depth as a continuous variable demonstrated that the inspection depth was associated with clinical pregnancy, implantation, and live birth rates (clinical pregnancy rate, adjusted odds ratio, 0.549; 95% confidence interval, 0.380-0.793; implantation rate, adjusted odds ratio, 0.680; 95% confidence interval, 0.496-0.931; live birth rate, adjusted odds ratio, 0.602; 95% confidence interval, 0.420-0.863), but not with the miscarriage rate. CONCLUSIONS The inspection depth of the uterine lumen measured by transvaginal ultrasound was associated with IVF success. TRIAL REGISTRATION This prospective observational study was registered at the Chinese Clinical Trial Registry ( www.chictr.org.cn ) (ChiCTR2200057977) on March 24, 2022, retrospectively registered.
Collapse
Affiliation(s)
- Na Zuo
- Center of Reproductive Medicine, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Sitong Dong
- Center of Reproductive Medicine, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Da Li
- Center of Reproductive Medicine, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Ningning Zhang
- Department of Obstetrics and Gynecology, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| | - Xiuxia Wang
- Center of Reproductive Medicine, Shengjing Hospital of China Medical University, Shenyang, 110004 China
| |
Collapse
|
17
|
Li Y, Samant P, Cochran C, zhao Y, Keyak JH, Hu X, Yu A, Xiang L. The feasibility study of XACT imaging for characterizing osteoporosis. Med Phys 2022; 49:7694-7702. [PMID: 35962866 PMCID: PMC10567061 DOI: 10.1002/mp.15906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 07/08/2022] [Accepted: 07/21/2022] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Osteoporosis is a progressive bone disease that is characterized by a decrease in bone mass and the deterioration in bone microarchitecture, which might be related to age and space travel. An unmet need exists for the development of novel imaging technologies to characterize osteoporosis. PURPOSE The purpose of our study is to investigate the feasibility of X-ray-induced acoustic computed tomography (XACT) imaging for osteoporosis detection. METHODS An in-house simulation workflow was developed to assess the ability of XACT for osteoporosis detection. To evaluate this simulation workflow, a three-dimensional digital bone phantom for XACT imaging was created by a series of two-dimensional micro-computed tomography (micro-CT) slices of normal and osteoporotic bones in mice. In XACT imaging, the initial acoustic pressure rise caused by the X-ray induce acoustic (XA) effect is proportional to bone density. First, region growing was deployed for image segmentation of different materials inside the bone. Then k-wave simulations were deployed to model XA wave propagation, attenuation, and detection. Finally, the time-varying pressure signals detected at each transducer location were used to reconstruct the XACT image with a time-reversal reconstruction algorithm. RESULTS Through the simulated XACT images, cortical porosity has been calculated, and XA signal spectra slopes have been analyzed for the detection of osteoporosis. The results have demonstrated that osteoporotic bones have lower bone mineral density and higher spectra slopes. These findings from XACT images were in good agreement with porosity calculation from micro-CT images. CONCLUSION This work explores the feasibility of using XACT imaging as a new imaging tool for Osteoporosis detection. Considering that acoustic signals are generated by X-ray absorption, XACT imaging can be combined with traditional X-ray imaging that holds potential for clinical management of osteoporosis and other bone diseases.
Collapse
Affiliation(s)
- Yizhou Li
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China
- School of Electrical and Computer Engineering, The University of Oklahoma, Norman, Oklahoma, USA
- Department of Orthopedics, Affiliated Hospital of Inner Mongolia Medical University, Inner Mongolia, China
| | - Pratik Samant
- School of Electrical and Computer Engineering, The University of Oklahoma, Norman, Oklahoma, USA
- Department of Oncology, University of Oxford, Oxford, UK
| | - Christian Cochran
- School of Electrical and Computer Engineering, The University of Oklahoma, Norman, Oklahoma, USA
| | - Yue zhao
- School of Electrical and Computer Engineering, The University of Oklahoma, Norman, Oklahoma, USA
| | - Joyce H. Keyak
- Department of Radiological Sciences, University of California, Irvine, Irvine, California, USA
| | - Xiang Hu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China
| | - Aixi Yu
- Department of Orthopedics Trauma and Microsurgery, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China
| | - Liangzhong Xiang
- School of Electrical and Computer Engineering, The University of Oklahoma, Norman, Oklahoma, USA
- Department of Radiological Sciences, University of California, Irvine, Irvine, California, USA
- Department of Biomedical Engineering, University of California, Irvine, Irvine, California, USA
- Beckman Laser Institute & Medical Clinic, University of California, Irvine, Irvine, California, USA
| |
Collapse
|
18
|
Hoffmeister BK, Main EN, Newman WR, Ebron SC, Huang J. Frequency dependence of the ultrasonic power reflected from the water-tissue interface of human cancellous bone in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 152:2082. [PMID: 36319263 DOI: 10.1121/10.0014417] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
Numerous studies have performed in vitro ultrasonic measurements of cancellous bone in water to develop techniques for ultrasonic bone assessment. Because cancellous bone is a highly porous medium, ultrasonic reflections at the water-bone interface may be frequency dependent. The goal of this study was to investigate the effect of porosity on the frequency dependence of the reflected power. Ultrasonic measurements were performed in a water tank at room temperature on 15 specimens of cancellous bone prepared from the proximal end of 9 human femurs using single element, broadband transducers with center frequencies of 3.5, 5, 7.5, and 10 MHz. Power spectra of pulses reflected from the water-specimen interface were corrected for the frequency response of the measurement system to obtain the reflected power in decibels RdB(f). To suppress random phase cancellation effects, RdB(f) was averaged over multiple sites on multiple specimens. A frequency dependence of RdB(f) was observed in the 2.6-10 MHz range. The frequency dependence was moderate, with a maximum change of less than 6 dB over the entire frequency range. RdB(f) was greatest for low porosity specimens. The frequency averaged intensity reflection coefficient ranged from 7.4 × 10-4 to 7.8 × 10-3 for high and low porosity specimen groups, respectively.
Collapse
Affiliation(s)
| | - Evan N Main
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Will R Newman
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Sheldon C Ebron
- Department of Physics, Rhodes College, Memphis, Tennessee 38112, USA
| | - Jinsong Huang
- College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee 38163, USA
| |
Collapse
|
19
|
Osteoporosis Screening: Applied Methods and Technological Trends. Med Eng Phys 2022; 108:103887. [DOI: 10.1016/j.medengphy.2022.103887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Revised: 08/30/2022] [Accepted: 09/01/2022] [Indexed: 11/15/2022]
|
20
|
Pakula M. What kind of waves are measured in trabecular bone? ULTRASONICS 2022; 123:106692. [PMID: 35176689 DOI: 10.1016/j.ultras.2022.106692] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 01/06/2022] [Accepted: 01/17/2022] [Indexed: 06/14/2023]
Abstract
The paper discusses the fundamental mechanisms underlying the interaction between ultrasound and trabecular bone, which is considered a two-phase material. When fluid-saturated cancellous bone is interrogated by ultrasound, in some cases, one or two wave modes are observed. Many authors claim that these waves correspond to the fast and slow waves predicted by Biot's theory of elastic wave propagation in fluid-saturated porous media. Within our analysis of the physical conditions, predictions of the existing two-phase models of the propagation of ultrasonic waves in the material as well as numerical simulations for fluid-saturated trabecular bone were performed. On the basis of the theoretical results (from numerical studies) and arguments presented in this paper, we aimed to answer the question of whether two waves observed in ultrasonic wave transmission studies can be interpreted as the fast and slow waves predicted by Biot's theory.
Collapse
Affiliation(s)
- Michal Pakula
- Faculty of Mechatronics, Kazimierz Wielki University in Bydgoszcz, Poland.
| |
Collapse
|
21
|
Hoffmeister BK, Delahunt SI, Downey KL, Viano AM, Thomas DM, Georgiou LA, Gray AJ, Newman WR, Main EN, Pirro G. In Vivo Comparison of Backscatter Techniques for Ultrasonic Bone Assessment at the Femoral Neck. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:997-1009. [PMID: 35282987 DOI: 10.1016/j.ultrasmedbio.2022.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 01/15/2022] [Accepted: 01/27/2022] [Indexed: 06/14/2023]
Abstract
Ultrasonic techniques are being developed to detect changes in cancellous bone caused by osteoporosis. The goal of this study was to test the relative in vivo performance of eight backscatter parameters developed over the last several years for ultrasonic bone assessment: apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), frequency intercept of apparent backscatter (FIAB), normalized mean of the backscatter difference (nMBD), normalized slope of the backscatter difference (nSBD), normalized intercept of the backscatter difference (nIBD), normalized backscatter amplitude ratio (nBAR) and backscatter amplitude decay constant (BADC). Backscatter measurements were performed on the left and right femoral necks of 80 adult volunteers (age = 25 ± 11 y) using an imaging system equipped with a convex array transducer. For comparison, additional ultrasonic measurements were performed at the left and right heel using a commercially available heel-bone ultrasonometer that measured the stiffness index. Six of the eight backscatter parameters (all but nSBD and nIBD) exhibited similar and highly significant (p < 0.000001) left-right correlations (0.51 ≤ R ≤ 0.68), indicating sensitivity to naturally occurring variations in bone tissue. Left-right correlations for the stiffness index measured at the heel (R = 0.75) were not significantly better than those produced by AIB, FSAB and FIAB. The short-term precisions of AIB, nMBD, nBAR and BADC (7.8%-11.7%) were comparable to that of the stiffness index measured with the heel-bone ultrasonometer (7.5%).
Collapse
Affiliation(s)
| | | | - Kiera L Downey
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Ann M Viano
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Doni M Thomas
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | | | - Aubrey J Gray
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Will R Newman
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Evan N Main
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| | - Gia Pirro
- Department of Physics, Rhodes College, Memphis, Tennessee, USA
| |
Collapse
|
22
|
Zhang S, Zhang X, Li Y, Mao X, Liu R, Qi Y, Lee ES, Jiang HB. Clinical Reference Strategy for the Selection of Treatment Materials for Maxillofacial Bone Transplantation: A Systematic Review and Network Meta-Analysis. Tissue Eng Regen Med 2022; 19:437-450. [PMID: 35532735 PMCID: PMC9130380 DOI: 10.1007/s13770-022-00445-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 10/27/2021] [Accepted: 11/01/2021] [Indexed: 10/18/2022] Open
Abstract
Bone graft materials have mixed effects of bone repair in the field of oral maxillofacial surgery. The qualitative analyses performed by previous studies imply that autogenous odontogenic materials and autogenous bone have similar effects on bone repair in clinical jaw bone transplantation. This retrospective systematic assessment and network meta-analysis aimed to analyze the best effect of clinical application of autogenous odontogenic materials and autogenous, allogeneic, and xenogeneic bone grafts in bone defect repair. A systematic review was performed by searching the PubMed, Cochrane Library, and other journal databases using selected keywords and Medical Subject Headings search terms. 10 Papers (n = 466) that met the inclusion criteria were selected. The assessment of heterogeneity did not reveal any overall statistical difference or heterogeneity (P = 0.051 > 0.05), whereas the comparison between autogenous and allogeneic bone grafts revealed local heterogeneity (P = 0.071 < 0.1). Risk of bias revealed nine unclear studies and one high-risk study. The overall consistency was good (P = 0.065 > 0.05), and the local inconsistency test did not reveal any inconsistency. The publication bias was good. The confidence regarding the ranking of bone graft materials after GRADE classification was moderate. The effects on bone repair in the descending order were as follows: autogenous odontogenic materials, xenogeneic bone, autogenous bone, and allogeneic bone. This result indicates that the autogenous odontogenic materials displayed stronger effects on bone repair compared to other bone graft materials. Autogenous odontogenic materials have broad development prospects in oral maxillofacial surgery.
Collapse
Affiliation(s)
- Shuxin Zhang
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Xinyi Zhang
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Yanli Li
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Xuran Mao
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Rui Liu
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Yanxin Qi
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China
| | - Eui-Seok Lee
- Department of Oral and Maxillofacial Surgery, Graduate School of Clinical Dentistry, Korea University, Seoul, 08308, Korea.
| | - Heng Bo Jiang
- The CONVERSATIONALIST club, School of Stomatology, Shandong First Medical University & Shandong Academy of Medical Sciences, Tai'an, 271016, Shandong, China.
| |
Collapse
|
23
|
Measurement of Ultrasound Parameters of Bovine Cancellous Bone as a Function of Frequency for a Range of Porosities via Through-Transmission Ultrasonic Spectroscopy. ACOUSTICS 2022. [DOI: 10.3390/acoustics4020025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The relationship between ultrasonic parameters (attenuation coefficients and velocity) and bone porosity in bovine cancellous bone is explored to understand the possibility of fracture risk diagnosis associated with osteoporosis by applying ultrasound. In vitro measurements of ultrasonic parameters on twenty-one bovine cancellous bone samples from tibia were conducted, using ultrasonic spectroscopy in the through-transmission mode. Transducers of three different center frequencies were used to cover a wide diagnostic frequency range between 1.0–7.8 MHz. The nonlinear relationship of porosity and normalized attenuation coefficient (nATTN) and normalized broadband attenuation coefficient (nBUA) were well described by a third-order polynomial fit, whereas porosity and the phase velocity (UV) were found to be negatively correlated with the linear correlation coefficients of −0.93, −0.89 and −0.83 at 2.25, 5.00 and 7.50 MHz, respectively. The results imply that the ultrasound parameters attain maximum values for the bone sample with the lowest porosity, and then decrease for samples with greater porosity for the range of porosities in our samples for all frequencies. Spatial variation in the ultrasound parameters was found to be caused by non-uniform pore size distribution, which was examined at five different locations within the same bone specimen. However, it did not affect the relationship of ultrasound parameters and porosity at these frequencies.
Collapse
|
24
|
Shi Q, Li Y, Liu Y, Gu M, Song X, Liu C, Ta D, Wang W. Index-Rotated Fast Ultrasound Imaging of Cortical Bone Based on Predicted Velocity Model. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1582-1595. [PMID: 35275812 DOI: 10.1109/tuffc.2022.3157256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Due to the significant acoustic impedance contrast at cortical boundaries, highly inside attenuation, and the unknown sound velocity distribution, accurate ultrasound cortical bone imaging remains a challenge, especially for the traditional pulse-echo modalities using unique sound velocity. Moreover, the large amounts of data recorded by multielement probe results in a relatively time-consuming reconstruction process. To overcome these limitations, this article proposed an index-rotated fast ultrasound imaging method based on predicted velocity model (IR-FUI-VP) for cortical cross section ultrasound tomography (UST) imaging, utilizing ray-tracing synthetic aperture (RTSA). In virtue of ring probe, the sound velocity model was predicted in advance using bent-ray inversion (BRI). With the predicted velocity model, index-rotated fast ultrasound imaging (IR-FUI) was further applied to image the cortical cross sections in the sectors corresponding to the dynamic apertures (DAs) and ring center. The final result was merged by all sector images. One cortical bone phantom and two ex vivo bovine femurs were utilized to demonstrate the performance of the proposed method. Compared to the conventional synthetic aperture (SA) imaging, the method can not only accurately image the outer cortical boundary but also precisely reconstruct the inner cortical surface. The mean relative errors of the predicted sound velocity in the region of interest (ROI) were all smaller than 7%, and the mean errors of cortical thickness are all less than 0.31 mm. The reconstructed images of bovine femurs were in good agreement with the reference images scanned by micro-computed tomography ( μ CT) with respect to the morphology and thickness. The speed of IR-FUI is about 3.73 times faster than the traditional SA. It is proved that the proposed IR-FUI-VP-based UST is an effective way for fast and accurate cortical bone imaging.
Collapse
|
25
|
He L, Wu D, Zhang J, Zheng S, Li Y, He W. Factors affecting transtemporal window quality in transcranial sonography. Brain Behav 2022; 12:e2543. [PMID: 35238499 PMCID: PMC9015004 DOI: 10.1002/brb3.2543] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 01/17/2022] [Accepted: 02/12/2022] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVE To assess the influencing factors of transtemporal window quality and identify patients suitable for transcranial sonography (TCS) examination in two-dimensional imaging. METHODS In this cross-sectional study, TCS was performed in 161 consecutive patients through the temporal bone window (TBW) in the neurology or neurosurgery department. Each patient's sex, age, height, weight, and temporal bone thickness (TBT) were collected. After examination, the patients were divided into two groups: TBW success and TBW failure. The data were statistically compared between the two groups. RESULTS Among the studied population, the total TBW success rate was 80.1% (95% confidence interval [CI]: 74-86). The TBW success rate was 91.4% (95% CI: 85-98) in males and 70.9% (95% CI: 61-81) in females (p = .001). Sex (p = .001), age (p = .002), height (p = .047), and TBT (p < .001) showed significant differences between the TBW success and failure groups. In males, only TBT (p = .001) showed a significant difference; in females, age (p < .001) and TBT (p = .003) showed a significant difference. The area under the receiver operating characteristic curve (AUC) of sex, age, and TBT and their combination was 0.686, 0.659, 0.842, and 0.922 (p < .001), respectively. The AUC of the combination of parameters was significantly greater than that of age and sex alone (p = .007; p = .0002) but not greater than that of TBT (p = .090). CONCLUSIONS The TBW success rate varied with sex, age, height, and TBT. Males, younger patients, taller patients, and patients with a thinner temporal bone tended to be more suitable for the examination by TCS.
Collapse
Affiliation(s)
- Lei He
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| | - Dong‐Fang Wu
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| | - Jing‐Han Zhang
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| | - Shuai Zheng
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| | - Yi Li
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| | - Wen He
- Department of UltrasoundBeijing Tiantan HospitalCapital Medical UniversityBeijingChina
| |
Collapse
|
26
|
Hsu HC, Wear KA, Joshua Pfefer T, Vogt WC. Tissue-mimicking phantoms for performance evaluation of photoacoustic microscopy systems. BIOMEDICAL OPTICS EXPRESS 2022; 13:1357-1373. [PMID: 35415004 PMCID: PMC8973174 DOI: 10.1364/boe.445702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 12/19/2021] [Accepted: 01/12/2022] [Indexed: 06/14/2023]
Abstract
Phantom-based performance test methods are critically needed to support development and clinical translation of emerging photoacoustic microscopy (PAM) devices. While phantoms have been recently developed for macroscopic photoacoustic imaging systems, there is an unmet need for well-characterized tissue-mimicking materials (TMMs) and phantoms suitable for evaluating PAM systems. Our objective was to develop and characterize a suitable dermis-mimicking TMM based on polyacrylamide hydrogels and demonstrate its utility for constructing image quality phantoms. TMM formulations were optically characterized over 400-1100 nm using integrating sphere spectrophotometry and acoustically characterized using a pulse through-transmission method over 8-24 MHz with highly confident extrapolation throughout the usable band of the PAM system. This TMM was used to construct a spatial resolution phantom containing gold nanoparticle point targets and a penetration depth phantom containing slanted tungsten filaments and blood-filled tubes. These phantoms were used to characterize performance of a custom-built PAM system. The TMM was found to be broadly tunable and specific formulations were identified to mimic human dermis at an optical wavelength of 570 nm and acoustic frequencies of 10-50 MHz. Imaging results showed that tungsten filaments yielded 1.1-4.2 times greater apparent maximum imaging depth than blood-filled tubes, which may overestimate real-world performance for vascular imaging applications. Nanoparticles were detectable only to depths of 120-200 µm, which may be due to the relatively weaker absorption of single nanoparticles vs. larger targets containing high concentration of hemoglobin. The developed TMMs and phantoms are useful tools to support PAM device characterization and optimization, streamline regulatory decision-making, and accelerate clinical translation.
Collapse
Affiliation(s)
- Hsun-Chia Hsu
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - Keith A. Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - T. Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| | - William C. Vogt
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20993, USA
| |
Collapse
|
27
|
Feng T, Xie Y, Xie W, Chen Y, Wang P, Li L, Han J, Ta D, Cheng L, Cheng Q. Characterization of multi-biomarkers for bone health assessment based on photoacoustic physicochemical analysis method. PHOTOACOUSTICS 2022; 25:100320. [PMID: 35004172 PMCID: PMC8717597 DOI: 10.1016/j.pacs.2021.100320] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 11/20/2021] [Accepted: 12/05/2021] [Indexed: 05/12/2023]
Abstract
Photoacoustic (PA) techniques are potential alternatives to histopathology. The physicochemical spectrogram (PCS) generated by the PA measurement at multiple wavelengths can presents the morphology and chemical composition target at multi-biomarkers simultaneously. In this work, via multi-wavelength PA measurements performed on rabbit bone models, we investigated the feasibility of using PCSs for bone health assessment. A comprehensive analysis of the PCSs, termed PA physicochemical analysis (PAPCA), was conducted. The "slope" and "relative content" were used as the PAPCA-quantified parameters to characterize the changes in the physical and chemical properties of bone tissue, respectively. The findings are consistent well with the gold-standard imaging results. It demonstrated that the PAPCA can be used to characterize both the microstructure and content of multi-biomarkers which highly related with bone health. Considering the PA technique is noninvasive and radiation-free, it has great potential in the implementation and monitoring of bone diseases progression.
Collapse
Affiliation(s)
- Ting Feng
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Yejing Xie
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Weiya Xie
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yingna Chen
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
| | - Peng Wang
- Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower Hospital, School of Medicine, Nanjing University, Nanjing 210008, Jiangsu, China
| | - Lan Li
- Department of Sports Medicine and Adult Reconstructive Surgery, Drum Tower Hospital, School of Medicine, Nanjing University, Nanjing 210008, Jiangsu, China
| | - Jing Han
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Dean Ta
- Department of Electronic Engineering, Fudan University, Shanghai 200433, China
| | - Liming Cheng
- The Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration, Ministry of Education, Department of Orthopaedics, Tongji Hospital, Tongji University School of Medicine, Shanghai 200065, China
| | - Qian Cheng
- Institute of Acoustics, School of Physics Science and Engineering, Tongji University, Shanghai 200092, China
- The Key Laboratory of Spine and Spinal Cord Injury Repair and Regeneration, Ministry of Education, Department of Orthopaedics, Tongji Hospital, Tongji University School of Medicine, Shanghai 200065, China
| |
Collapse
|
28
|
Xu R, O'Reilly MA. Establishing density-dependent longitudinal sound speed in the vertebral lamina. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:1516. [PMID: 35364923 DOI: 10.1121/10.0009316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 12/26/2021] [Indexed: 06/14/2023]
Abstract
Focused ultrasound treatments of the spinal cord may be facilitated using a phased array transducer and beamforming to correct spine-induced focal aberrations. Simulations can non-invasively calculate aberration corrections using x-ray computed tomography (CT) data that are correlated to density (ρ) and longitudinal sound speed (cL). We aimed to optimize vertebral lamina-specific cL(ρ) functions at a physiological temperature (37 °C) to maximize time domain simulation accuracy. Odd-numbered ex vivo human thoracic vertebrae were imaged with a clinical CT-scanner (0.511 × 0.511 × 0.5 mm), then sonicated with a transducer (514 kHz) focused on the canal via the vertebral lamina. Vertebra-induced signal time shifts were extracted from pressure waveforms recorded within the canals. Measurements were repeated 5× per vertebra, with 2.5 mm vertical vertebra shifts between measurements. Linear functions relating cL with CT-derived density were optimized. The optimized function was cL(ρ)=0.35(ρ-ρw)+ cL,w m/s, where w denotes water, giving the tested laminae a mean bulk density of 1600 ± 30 kg/m3 and a mean bulk cL of 1670 ± 60 m/s. The optimized lamina cL(ρ) function was accurate to λ/16 when implemented in a multi-layered ray acoustics model. This modelling accuracy will improve trans-spine ultrasound beamforming.
Collapse
Affiliation(s)
- Rui Xu
- Department of Medical Biophysics, University of Toronto, 101 College Street, Suite 15-701, Toronto, Ontario, M5G 1L7, Canada
| | - Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario, M4N 3M5, Canada
| |
Collapse
|
29
|
Fielder M, Nair AK. Effects of scattering on ultrasound wave transmission through bioinspired scaffolds. J Mech Behav Biomed Mater 2022; 126:105065. [PMID: 34974324 DOI: 10.1016/j.jmbbm.2021.105065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 12/23/2021] [Accepted: 12/24/2021] [Indexed: 01/24/2023]
Abstract
Enhancing tissue growth in scaffolds using ultrasound waves while maintaining the structural integrity of the scaffolds is a challenging problem. Previous studies have primarily focused on the effect of ultrasound waves directly on the tissue, but how the ultrasound wave interacts with the scaffold needs to be further understood, which will have a significant effect on the response of tissue to mechanical stimulation. In this study we investigate how ultrasound wave transmission differs between scaffolds with uniform pore shapes (triangle, square, rectangle, hexagon) and a bioinspired scaffold with higher structural integrity that is inspired from the atomic structure of hydroxyapatite which is a primary component of bone. We use finite element method and ultrasound experiments on 3D-printed scaffolds composed of Acrylonitrile butadiene styrene (ABS) with constant porosity to predict the effect of pore shape and wave signal frequency in the range of 1-20 MHz on acoustic wave scattering and transmission. We find that the pore shape of the scaffold affects the magnitude of ultrasound transmission even when porosity is constant, and that the bioinspired scaffolds can allow as much as 67% more wave transmission compared to scaffolds with rectangular or square pore shapes at 1 MHz frequency. Triangular and hexagonal pores are also found to produce more nonuniform transmitted wavefronts compared to the square and rectangular pores. Peak density is defined as the number of local extrema of the transmitted wave frequency power spectrum and measures the uniformity of the transmitted wave. We find that a higher peak density value for the bioinspired scaffold due to its nonsymmetric structure further produces more nonuniform wave scattering. The results of this study are important for designing bioinspired tissue scaffold geometries to control ultrasound wave penetration and to enhance mechanical stimulation for tissue growth and will also aid in the ultrasonic characterization of porous structures based on changes in pore geometry.
Collapse
Affiliation(s)
- Marco Fielder
- Multiscale Materials Modeling Lab, Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA
| | - Arun K Nair
- Multiscale Materials Modeling Lab, Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA; Institute for Nanoscience and Engineering, 731 W. Dickson Street, University of Arkansas, Fayetteville, AR, USA.
| |
Collapse
|
30
|
Cutolo MA, Cafiero C, Califano L, Giaquinto M, Cusano A, Cutolo A. Feasibility analysis of an ultrasound on line diagnostic approach for oral and bone surgery. Sci Rep 2022; 12:905. [PMID: 35042892 PMCID: PMC8766520 DOI: 10.1038/s41598-022-04857-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Accepted: 12/15/2021] [Indexed: 11/08/2022] Open
Abstract
During implant surgery procedures, surgical precision is an essential prerequisite for the functional and aesthetic success of the prosthetic crown to be placed on the dental implant. A modern implant surgical approach should be standardized as much as possible to guarantee extreme precision in the insertion of the implant into the upper and lower bone jaws. Among the most common surgical errors during implant surgery there is the over-preparation of the surgical alveolus with possible damage to the contiguous anatomical structures. To avoid this problem, in the recent years, there has been an increasing attention to the development of new control techniques. In this paper, we describe an innovative ultrasound approach, which exploits the integration of an electro-acoustic transducer with the surgical drill used for realizing the alveolus in the bone that will host the implant. Specifically, he proposed approach is based on the "time-of-flight" detection technique for measuring the thickness of the residual bone subjected to the drilling. In order to demonstrate the feasibility of the proposed approach, here we report on a detailed numerical analysis aimed at studying the propagation of ultrasonic waves through the drill-bit and through the involved tissues. The obtained results confirm the validity of our approach, and enable for a future first prototype implementation of a hi-tech surgical drill-bit, which in general is suitable not only for dental implant surgery but also for other uses in oral surgery, maxillofacial surgery and for bone surgery.
Collapse
Affiliation(s)
- Maria Alessandra Cutolo
- Regional Center on Information Communication Technology (CeRICT) scrl, 82100, Benevento, Italy
| | - Carlo Cafiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", 80131, Naples, Italy
| | - Luigi Califano
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples "Federico II", 80131, Naples, Italy
| | - Martino Giaquinto
- Optoelectronics Group, Engineering Department, University of Sannio, 82100, Benevento, Italy.
| | - Andrea Cusano
- Optoelectronics Group, Engineering Department, University of Sannio, 82100, Benevento, Italy
| | - Antonello Cutolo
- Department of Electrical Engineering and Information Technology, University of Naples "Federico II", 80121, Naples, Italy
| |
Collapse
|
31
|
Wang CY, Chu SY, Lin YC, Tsai YW, Tai CL, Yang KC, Tsui PH. Quantitative imaging of ultrasound backscattered signals with information entropy for bone microstructure characterization. Sci Rep 2022; 12:414. [PMID: 35013540 PMCID: PMC8748747 DOI: 10.1038/s41598-021-04425-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Accepted: 12/08/2021] [Indexed: 12/19/2022] Open
Abstract
Osteoporosis is a critical problem during aging. Ultrasound signals backscattered from bone contain information associated with microstructures. This study proposed using entropy imaging to collect the information in bone microstructures as a possible solution for ultrasound bone tissue characterization. Bone phantoms with different pounds per cubic foot (PCF) were used for ultrasound scanning by using single-element transducers of 1 (nonfocused) and 3.5 MHz (nonfocused and focused). Clinical measurements were also performed on lumbar vertebrae (L3 spinal segment) in participants with different ages (n = 34) and postmenopausal women with low or moderate-to-high risk of osteoporosis (n = 50; identified using the Osteoporosis Self-Assessment Tool for Taiwan). The signals backscattered from the bone phantoms and subjects were acquired for ultrasound entropy imaging by using sliding window processing. The independent t-test, one-way analysis of variance, Spearman correlation coefficient rs, and the receiver operating characteristic (ROC) curve were used for statistical analysis. The results indicated that ultrasound entropy imaging revealed changes in bone microstructures. Using the 3.5-MHz focused ultrasound, small-window entropy imaging (side length: one pulse length of the transducer) was found to have high performance and sensitivity in detecting variation among the PCFs (rs = − 0.83; p < 0.05). Small-window entropy imaging also performed well in discriminating young and old participants (p < 0.05) and postmenopausal women with low versus moderate-to-high osteoporosis risk (the area under the ROC curve = 0.80; cut-off value = 2.65; accuracy = 86.00%; sensitivity = 71.43%; specificity = 88.37%). Ultrasound small-window entropy imaging has great potential in bone tissue characterization and osteoporosis assessment.
Collapse
Affiliation(s)
- Chiao-Yin Wang
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyüan, Taiwan
| | - Sung-Yu Chu
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyüan, Taiwan
| | - Yu-Ching Lin
- Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Keelung and Chang Gung University, Taoyüan, Taiwan
| | - Yu-Wei Tsai
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyüan, Taiwan
| | - Ching-Lung Tai
- Graduate Institute of Biomedical Engineering, Chang Gung University, Taoyüan, Taiwan
| | - Kuen-Cheh Yang
- Department of Family Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Po-Hsiang Tsui
- Department of Medical Imaging and Radiological Sciences, College of Medicine, Chang Gung University, Taoyüan, Taiwan. .,Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital at Linkou, Taoyüan, Taiwan. .,Division of Pediatric Gastroenterology, Department of Pediatrics, Chang Gung Memorial Hospital at Linkou, Taoyüan, Taiwan.
| |
Collapse
|
32
|
Ultrasonic Assessment of Cancellous Bone Based on the Two-Wave Phenomenon. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:119-143. [DOI: 10.1007/978-3-030-91979-5_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
33
|
Viano AM, Ankersen JP, Hoffmeister BK, Huang J, Fairbanks LC. Ultrasonic Bone Assessment: Ability of Apparent Backscatter Techniques to Detect Changes in the Microstructure of Human Cancellous Bone. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:3309-3325. [PMID: 34138705 DOI: 10.1109/tuffc.2021.3090359] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Ultrasonic backscatter techniques may offer a useful approach for detecting changes in bone caused by osteoporosis. The goal of this study was to investigate how bone mineral density (BMD) and the microstructure of human cancellous bone affect three ultrasonic backscatter parameters that have been identified as potentially useful for ultrasonic bone assessment purposes: the apparent integrated backscatter (AIB), the frequency slope of apparent backscatter (FSAB), and the frequency intercept of apparent backscatter (FIAB). Ultrasonic measurements were performed with a 3.5-MHz broadband transducer on 54 specimens of human cancellous bone prepared from the proximal femur. Microstructural parameters and BMD were measured using X-ray microcomputed tomography (micro-CT). Relationships between AIB, FSAB, FIAB, and the micro-CT parameters were investigated using univariate and multivariate statistical analysis techniques. Moderate-to-strong univariate correlations were observed between the backscatter parameters and microstructure and BMD in many cases. The partial correlation analysis indicated that the backscatter parameters are dependent on microstructure independently of BMD in some cases. Multiple stepwise linear regression analysis used to generate multivariate models found that microstructure was a significant predictor of the backscatter parameters in most cases.
Collapse
|
34
|
Feng T, Zhu Y, Morris R, kozloff KM, Wang X. The feasibility study of the transmission mode photoacoustic measurement of human calcaneus bone in vivo. PHOTOACOUSTICS 2021; 23:100273. [PMID: 34745881 PMCID: PMC8552339 DOI: 10.1016/j.pacs.2021.100273] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 05/04/2021] [Accepted: 05/12/2021] [Indexed: 05/26/2023]
Abstract
The photoacoustic (PA) technique is uniquely positioned for biomedical applications primarily due to its ability to visualize optical absorption contrast in deep tissue at ultrasound resolution. In this work, via both three-dimensional (3D) numerical simulations and in vivo experiments on human subjects, we investigated the possibility of PA measurement of human calcaneus bones in vivo in a non-invasive manner, as well as its feasibility to differentiate osteoporosis patients from normal subjects. The results from the simulations and the experiments both demonstrated that, when one side of the heel is illuminated by laser with light fluence under the ANSI safety limit, the PA signal generated in the human calcaneus bone can be detected by an ultrasonic transducer at the other side of the heel (i.e. transmission mode). Quantitative power spectral analyses of the calcaneus bone PA signals were also conducted, demonstrating that the microarchitectural changes in calcaneus bone due to osteoporosis can be detected, as reflected by enhanced high frequency components in detected PA bone signal. Further statistical analysis of the experimental results from 10 osteoporosis patients and 10 healthy volunteers showed that the weighted frequency as a quantified PA spectral parameter can differentiate the two subject groups with statistical significance.
Collapse
Affiliation(s)
- Ting Feng
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
| | - Yunhao Zhu
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
| | | | - Kenneth M. kozloff
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
- Department of Orthopaedic Surgery, University of Michigan Medical School, MI 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
- Department of Radiology, University of Michigan Medical School, MI 48109, USA
| |
Collapse
|
35
|
Jing B, Lindsey BD. Effect of Skull Porous Trabecular Structure on Transcranial Ultrasound Imaging in the Presence of Elastic Wave Mode Conversion at Varying Incidence Angle. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2734-2748. [PMID: 34140169 DOI: 10.1016/j.ultrasmedbio.2021.05.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Revised: 05/04/2021] [Accepted: 05/07/2021] [Indexed: 06/12/2023]
Abstract
With the advancement of aberration correction techniques, transcranial ultrasound imaging has exhibited great potential in applications such as imaging neurological function and guiding therapeutic ultrasound. However, the feasibility of transcranial imaging varies among individuals because of the differences in skull acoustic properties. To better understand the fundamental mechanisms underlying the variation in imaging performance, the effect of the structure of the porous trabecular bone on transcranial imaging performance (i.e., target localization errors and resolution) was investigated for the first time through the use of elastic wave simulations and experiments. Simulation studies using high-resolution computed tomography data from ex vivo skull samples revealed that imaging at large incidence angles reduced the target localization error for skulls having low porosity; however, as skull porosity increased, large angles of incidence resulted in degradation of resolution and increased target localization errors. Experimental results indicate that imaging at normal incidence introduced a localization error of 1.85 ± 0.10 mm, while imaging at a large incidence angle (40°) resulted in an increased localization error of 6.54 ± 1.33 mm and caused a single point target to no longer appear as a single, coherent target in the resulting image, which is consistent with simulation results. This first investigation of the effects of skull microstructure on transcranial ultrasound imaging indicates that imaging performance is highly dependent on the porosity of the skull, particularly at non-normal angles of incidence.
Collapse
Affiliation(s)
- Bowen Jing
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Brooks D Lindsey
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA; School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
| |
Collapse
|
36
|
Li Y, Shi Q, Liu Y, Gu M, Liu C, Song X, Ta D, Wang W. Fourier-Domain Ultrasonic Imaging of Cortical Bone Based on Velocity Distribution Inversion. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2619-2634. [PMID: 33844628 DOI: 10.1109/tuffc.2021.3072657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
There is a significant acoustic impedance contrast between the cortical bone and the surrounding soft tissue, resulting in difficulty for ultrasound penetration into bone tissue with high frequency. It is challenging for the conventional pulse-echo modalities to give accurate cortical bone images using uniform sound velocity model. To overcome these limitations, an ultrasound imaging method called full-matrix Fourier-domain synthetic aperture based on velocity inversion (FM-FDSA-VI) was developed to provide accurate cortical bone images. The dual linear arrays were located on the upper and lower sides of the imaging region. After full-matrix acquisition with two identical linear array probes facing each other, travel-time inversion was used to estimate the velocity distribution in advance. Then, full-matrix Fourier-domain synthetic aperture (FM-FDSA) imaging based on the estimated velocity model was applied twice to image the cortical bone, utilizing the data acquired from top and bottom linear array, respectively. Finally, to further improve the image quality, the two images were merged to give the ultimate result. The performance of the method was verified by two simulated models and two bone phantoms (i.e., regular and irregular hollow bone phantom). The mean relative errors of estimated sound velocity in the region-of-interest (ROI) are all below 12%, and the mean errors of cortical section thickness are all less than 0.3 mm. Compared to the conventional synthetic aperture (SA) imaging, the FM-FDSA-VI method is able to accurately image cortical bone with respect to the structure. Moreover, the result of irregular bone phantom was close to the image scanned by microcomputed tomography ( μ CT) in terms of macro geometry and thickness. It is demonstrated that the proposed FM-FDSA-VI method is an efficient way for cortical bone ultrasonic imaging.
Collapse
|
37
|
Bi D, Dai Z, Liu D, Wu F, Liu C, Li Y, Li B, Li Z, Li Y, Ta D. Ultrasonic Backscatter Measurements of Human Cortical and Trabecular Bone Densities in a Head-Down Bed-Rest Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:2404-2415. [PMID: 34052063 DOI: 10.1016/j.ultrasmedbio.2021.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2020] [Revised: 03/24/2021] [Accepted: 04/02/2021] [Indexed: 06/12/2023]
Abstract
This study aims to investigate the feasibility of quantitative ultrasonic backscatter in evaluating human cortical and trabecular bone densities in vivo based on a head-down-tilt bed rest study, with 36 participants tested through 90 d of bed rest and 180 d of recovery. Backscatter measurements were performed using an ultrasonic backscatter bone diagnostic instrument. Backscatter parameters were calculated with a dynamic signal-of-interest method, which was proposed to ensure the same ultrasonic interrogated volume in cortical and trabecular bones. The backscatter parameters exhibited significant correlations with site-matched bone densities provided by high-resolution peripheral quantitative computed tomography (0.33 < |R| < 0.72, p < 0.05). Some bone densities and backscatter parameters exhibited significant changes after the 90-d bed rest. The proposed method can be used to characterize bone densities, and the portable ultrasonic backscatter bone diagnostic device might be used to non-invasively reveal mean bone loss (across a group of people) after long-term bed rest and microgravity conditions of spaceflight missions.
Collapse
Affiliation(s)
- Dongsheng Bi
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Zhongquan Dai
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Duwei Liu
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Feng Wu
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Chengcheng Liu
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Ying Li
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China
| | - Boyi Li
- Academy for Engineering and Technology, Fudan University, Shanghai, China
| | - Zhili Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Yinghui Li
- State Key Laboratory of Space Medicine Fundamentals and Application, China Astronaut Research and Training Center, Beijing, China
| | - Dean Ta
- Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, China; Academy for Engineering and Technology, Fudan University, Shanghai, China.
| |
Collapse
|
38
|
Hariri A, Palma-Chavez J, Wear KA, Pfefer TJ, Jokerst JV, Vogt WC. Polyacrylamide hydrogel phantoms for performance evaluation of multispectral photoacoustic imaging systems. PHOTOACOUSTICS 2021; 22:100245. [PMID: 33747787 PMCID: PMC7972966 DOI: 10.1016/j.pacs.2021.100245] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 12/09/2020] [Accepted: 02/12/2021] [Indexed: 05/21/2023]
Abstract
As photoacoustic imaging (PAI) begins to mature and undergo clinical translation, there is a need for well-validated, standardized performance test methods to support device development, quality control, and regulatory evaluation. Despite recent progress, current PAI phantoms may not adequately replicate tissue light and sound transport over the full range of optical wavelengths and acoustic frequencies employed by reported PAI devices. Here we introduce polyacrylamide (PAA) hydrogel as a candidate material for fabricating stable phantoms with well-characterized optical and acoustic properties that are biologically relevant over a broad range of system design parameters. We evaluated suitability of PAA phantoms for conducting image quality assessment of three PAI systems with substantially different operating parameters including two commercial systems and a custom system. Imaging results indicated that appropriately tuned PAA phantoms are useful tools for assessing and comparing PAI system image quality. These phantoms may also facilitate future standardization of performance test methodology.
Collapse
Affiliation(s)
- Ali Hariri
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Jorge Palma-Chavez
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
| | - Keith A Wear
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - T Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| | - Jesse V Jokerst
- Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, USA
- Department of Radiology, University of California San Diego, La Jolla, CA 92093, USA
- Materials Science and Engineering Program, University of California San Diego, La Jolla, CA 92093, USA
| | - William C Vogt
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD 20993, USA
| |
Collapse
|
39
|
Wear KA. Hydrophone Spatial Averaging Correction for Acoustic Exposure Measurements From Arrays-Part I: Theory and Impact on Diagnostic Safety Indexes. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:358-375. [PMID: 33186102 PMCID: PMC8325172 DOI: 10.1109/tuffc.2020.3037946] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This article reports underestimation of mechanical index (MI) and nonscanned thermal index for bone near focus (TIB) due to hydrophone spatial averaging effects that occur during acoustic output measurements for clinical linear and phased arrays. TIB is the appropriate version of thermal index (TI) for fetal imaging after ten weeks from the last menstrual period according to the American Institute of Ultrasound in Medicine (AIUM). Spatial averaging is particularly troublesome for highly focused beams and nonlinear, nonscanned modes such as acoustic radiation force impulse (ARFI) and pulsed Doppler. MI and variants of TI (e.g., TIB), which are displayed in real-time during imaging, are often not corrected for hydrophone spatial averaging because a standardized method for doing so does not exist for linear and phased arrays. A novel analytic inverse-filter method to correct for spatial averaging for pressure waves from linear and phased arrays is derived in this article (Part I) and experimentally validated in a companion article (Part II). A simulation was developed to estimate potential spatial-averaging errors for typical clinical ultrasound imaging systems based on the theoretical inverse filter and specifications for 124 scanner/transducer combinations from the U.S. Food and Drug Administration (FDA) 510(k) database from 2015 to 2019. Specifications included center frequency, aperture size, acoustic output parameters, hydrophone geometrical sensitive element diameter, etc. Correction for hydrophone spatial averaging using the inverse filter suggests that maximally achievable values for MI, TIB, thermal dose ( t 43 ), and spatial-peak-temporal-average intensity ( [Formula: see text]) for typical clinical systems are potentially higher than uncorrected values by (means ± standard deviations) 9% ± 4% (ARFI MI), 19% ± 15% (ARFI TIB), 50% ± 41% (ARFI t 43 ), 43% ± 39% (ARFI [Formula: see text]), 7% ± 5% (pulsed Doppler MI), 15% ± 11% (pulsed Doppler TIB), 42% ± 31% (pulsed Doppler t 43 ), and 33% ± 27% (pulsed Doppler [Formula: see text]). These values correspond to frequencies of 3.2 ± 1.3 (ARFI) and 4.1 ± 1.4 MHz (pulsed Doppler), and the model predicts that they would increase with frequency. Inverse filtering for hydrophone spatial averaging significantly improves the accuracy of estimates of MI, TIB, t 43 , and [Formula: see text] for ARFI and pulsed Doppler signals.
Collapse
|
40
|
Athanasios T, Konstantinos A, Despoina D. Three-dimensional-printed replica models of bone for experimentally decoupling trabecular bone properties contribution to ultrasound propagation parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:296. [PMID: 33514143 DOI: 10.1121/10.0003048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Accepted: 12/11/2020] [Indexed: 06/12/2023]
Abstract
A detailed investigation of the relationship between ultrasonic (US) properties and trabecular bone microstructure is difficult because of the great variability in the bone loss process. The aim of this work was twofold. First, to verify by compressive tests that the three-dimensional (3D)-printer is able to produce precisely and repeatedly "bone replica models" of different size and density. Following, replicas of the original specimens with two different polymers and thinned trabeculae models were used to investigate US properties (speed of sound, SOS, and backscatter coefficient), aiming to deconvolute the influence of material properties on ultrasound characteristics. The results revealed that matrix material properties influence only the magnitude of the backscatter coefficient, whereas the characteristic undulated patterns are related to the trabecular structure. Simulation of perforation and thinning of cancellous bone, associated with bone loss, showed that SOS and mechanical properties were reduced perfectly linearly with apparent density when structure deteriorated. The 3D-printed bone replicas have the potential to enable systematic investigations of the influence of structure on both acoustical and mechanical properties and evaluate changes caused by bone loss. The development of replicas from materials with properties close to those of bone will permit quantitative conclusions for trabecular bone.
Collapse
Affiliation(s)
- Tsirigotis Athanasios
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| | - Apostolopoulos Konstantinos
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| | - Deligianni Despoina
- Laboratory of Biomechanics and Biomedical Engineering, Department of Mechanical Engineering & Aeronautics, University of Patras, Rio, Greece
| |
Collapse
|
41
|
Feng T, Zhu Y, Morris R, Kozloff KM, Wang X. Functional Photoacoustic and Ultrasonic Assessment of Osteoporosis: A Clinical Feasibility Study. BME FRONTIERS 2020; 2020:1081540. [PMID: 37849970 PMCID: PMC10521673 DOI: 10.34133/2020/1081540] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Accepted: 09/02/2020] [Indexed: 10/19/2023] Open
Abstract
Objective and Impact Statement. To study the feasibility of combined functional photoacoustic (PA) and quantitative ultrasound (US) for diagnosis of osteoporosis in vivo based on the detection of chemical and microarchitecture (BMA) information in calcaneus bone. Introduction. Clinically available X-ray or US technologies for the diagnosis of osteoporosis do not report important parameters such as chemical information and BMA. With unique advantages, including good sensitivity to molecular and metabolic properties, PA bone assessment techniques hold a great potential for clinical translation. Methods. By performing multiwavelength PA measurements, the chemical information in the human calcaneus bone, including mineral, lipid, oxygenated-hemoglobin, and deoxygenated-hemoglobin, were assessed. In parallel, by performing PA spectrum analysis, the BMA as an important bone physical property was quantified. An unpaired t -test and a two-way ANOVA test were conducted to compare the outcomes from the two subject groups. Results. Multiwavelength PA measurement is capable of assessing the relative contents of several chemical components in the trabecular bone in vivo, including both minerals and organic materials such as oxygenated-hemoglobin, deoxygenated-hemoglobin, and lipid, which are relevant to metabolic activities and bone health. In addition, PA measurements of BMA show good correlations (R 2 up to 0.65) with DEXA. Both the chemical and microarchitectural measurements from PA techniques can differentiate the two subject groups. Conclusion. The results from this initial clinical study suggest that PA techniques, by providing additional chemical and microarchitecture information relevant to bone health, may lead to accurate and early diagnosis, as well as sensitive monitoring of the treatment of osteoporosis.
Collapse
Affiliation(s)
- Ting Feng
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
| | - Yunhao Zhu
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
| | | | - Kenneth M. Kozloff
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
- Department of Orthopaedic Surgery, University of Michigan Medical School, MI 48109, USA
| | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan Medical School, MI 48109, USA
- Department of Radiology, University of Michigan Medical School, MI 48109, USA
| |
Collapse
|
42
|
Blondel M, Abidine Y, Assemat P, Palierne S, Swider P. Identification of effective elastic modulus using modal analysis; application to canine cancellous bone. J Biomech 2020; 110:109972. [PMID: 32827789 DOI: 10.1016/j.jbiomech.2020.109972] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 07/03/2020] [Accepted: 07/20/2020] [Indexed: 10/23/2022]
Abstract
Mechanical properties of cancellous bone is of increasing interest due to its involvement in aging pathologies and oncology. Characterization of fragile bone tissue is challenging and available methodologies include quasi-static compressive tests of small size specimens, ultrasound and indentation techniques. We hypothesized that modal analysis of flexure beams could be a complementary methodology to obtain Young modulus. The sampling methodology was adapted such that the uniqueness of the linear dynamic response was available to determine the elastic modulus from natural frequencies and mode shapes. In a first step, the methodology was validated using a synthetic bone model as control. Then, water-jet cutting allowed collecting fourteen small beam-like specimens in canine distal femurs. X-ray microtomography confirmed the microarchitecture preservation, the homogeneity and the isotropy at the specimen scale to derive effective properties. The first natural frequency in clamped-free boundary conditions was used to obtain mean values of Young modulus, which ranged from 210 MPa to 280 MPa depending on the specimen collection site. Experimental tests were rapid and reproducible and our preliminary results were in good agreement with literature data. In conclusion, beam modal analysis could be considered for exploring mechanical properties of fragile and scarce biological tissues.
Collapse
Affiliation(s)
- M Blondel
- National Veterinary School, Toulouse, France
| | - Y Abidine
- IMFT UMR 5502, Toulouse University, Toulouse, France
| | - P Assemat
- IMFT UMR 5502, Toulouse University, Toulouse, France
| | - S Palierne
- National Veterinary School, Toulouse, France
| | - P Swider
- IMFT UMR 5502, Toulouse University, Toulouse, France.
| |
Collapse
|
43
|
Il Lee K. Relationships of the ultrasonic backscatter measurements with the bone mineral density and the microarchitectural parameters in bovine trabecular bone in vitro. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:EL51. [PMID: 32752773 DOI: 10.1121/10.0001605] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 07/01/2020] [Indexed: 06/11/2023]
Abstract
Relationships of the backscatter coefficient (BC), the apparent integrated backscatter (AIB), and the integrated reflection coefficient (IRC) with the bone mineral density (BMD) and the microarchitectural parameters were investigated in 28 bovine femoral trabecular bone samples. The BC was highly correlated with the BMD and the microarchitectural parameters (R = -0.66 to 0.71). In contrast, the AIB and the IRC exhibited high correlations with the BMD and the bone volume fraction (R = -0.68 to 0.77) and relatively lower correlations with the remaining microarchitectural parameters (R = -0.62 to 0.60). The multiple regression models yielded the adjusted squared correlation coefficients of 0.54-0.76.
Collapse
Affiliation(s)
- Kang Il Lee
- Department of Physics, Kangwon National University, Chuncheon 24341, Republic of
| |
Collapse
|