Oliveira IM, Gomes IB, Simões LC, Simões M. A review of research advances on disinfection strategies for biofilm control in drinking water distribution systems. WATER RESEARCH 2024; 253:121273. [PMID: 38359597 DOI: 10.1016/j.watres.2024.121273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/17/2024]
Abstract
The presence of biofilms in drinking water distribution systems (DWDS) is responsible for water quality deterioration and a possible source of public health risks. Different factors impact the biological stability of drinking water (DW) in the distribution networks, such as the presence and concentration of nutrients, water temperature, pipe material composition, hydrodynamic conditions, and levels of disinfectant residual. This review aimed to evaluate the current state of knowledge on strategies for DW biofilm disinfection through a qualitative and quantitative analysis of the literature published over the last decade. A systematic review method was performed on the 562 journal articles identified through database searching on Web of Science and Scopus, with 85 studies selected for detailed analysis. A variety of disinfectants were identified for DW biofilm control such as chlorine, chloramine, UV irradiation, hydrogen peroxide, chlorine dioxide, ozone, and others at a lower frequency, namely, electrolyzed water, bacteriophages, silver ions, and nanoparticles. The disinfectants can impact the microbial communities within biofilms, reduce the number of culturable cells and biofilm biomass, as well as interfere with the biofilm matrix components. The maintenance of an effective residual concentration in the water guarantees long-term prevention of biofilm formation and improves the inactivation of detached biofilm-associated opportunistic pathogens. Additionally, strategies based on multi-barrier processes by optimization of primary and secondary disinfection combined with other water treatment methods improve the control of opportunistic pathogens, reduce the chlorine-tolerance of biofilm-embedded cells, as well as decrease the corrosion rate in metal-based pipelines. Most of the studies used benchtop laboratory devices for biofilm research. Even though these devices mimic the conditions found in real DWDS, future investigations on strategies for DW biofilm control should include the validity of the promising strategies against biofilms formed in real DW networks.
Collapse
Affiliation(s)
- Isabel Maria Oliveira
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal
| | - Inês Bezerra Gomes
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal
| | - Lúcia Chaves Simões
- CEB - Centre of Biological Engineering, University of Minho, Campus de Gualtar, 4710-057 Braga, Portugal; LABBELS - Associate Laboratory in Biotechnology, Bioengineering and Microelectromechanical Systems, Braga/Guimarães, Portugal
| | - Manuel Simões
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal; ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal.
| |
Collapse
|
2
|
Pan R, Zhang TY, Zheng ZX, Ai J, Ye T, Zhao HX, Hu CY, Tang YL, Fan JJ, Geng B, Xu B. Insight into mixed chlorine/chloramines conversion and associated water quality variability in drinking water distribution systems. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 880:163297. [PMID: 37028653 DOI: 10.1016/j.scitotenv.2023.163297] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/29/2023] [Accepted: 04/01/2023] [Indexed: 05/27/2023]
Abstract
Mixed chlorine/chloramines are common in drinking water distribution systems (DWDSs); however, their transformation and impact on chemical and microbial characteristics are not well understood. We systematically investigated water quality parameters associated with mixed chlorine/chloramine species conversion in 192 samples (including raw, finished, and tap water) collected throughout the year in a city in East China. Various chlorine/chloramine species (free chlorine, monochloramine [NH2Cl], dichloramine [NHCl2], and organic chloramines [OC]) were detected in both chlorinated and chloraminated DWDSs. NHCl2 + OC increased with transport distance along the pipeline network. The maximum proportion of NHCl2 + OC in over total chlorine in tap water reached 66 % and 38 % from chlorinated and chloraminated DWDSs, respectively. Both free chlorine and NH2Cl showed a rapid decay in the water pipe systems, but NHCl2 and OC were more persistent. Correlations between chlorine/chloramine species and physicochemical parameters were established. Models for predicting the sum of chloroform/TCM, bromodichloromethane/BDCM, chlorodibromomethane/CBDM, and bromoform/TBM (THM4) (R2 = 0.56) and haloacetic acids (HAAs) (R2 = 0.65) exhibited greater accuracy based on machine learning tuned with chlorine/chloramine species, particularly NHCl2 + OC. The predominant bacterial communities in mixed chlorine/chloramine systems were those resistant to chlorine or chloramine such as proteobacteria. NH2Cl was the most significant explanatory factor (28.1 %) for the variation in microbial community assemblage in chloraminated DWDSs. Although residual free chlorine and NHCl2 + OC, accounted for a smaller proportion of chlorine species in chloraminated DWDSs, they played an essential role (12.4 % and 9.1 %, respectively) in the microbial community structure.
Collapse
Affiliation(s)
- Renjie Pan
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Tian-Yang Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Zheng-Xiong Zheng
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jian Ai
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Tao Ye
- Department of Civil and Environmental Engineering, South Dakota School of Mines and Technology, Rapid City, SD 57701, USA
| | - Heng-Xuan Zhao
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Chen-Yan Hu
- College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, PR China
| | - Yu-Lin Tang
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China
| | - Jing-Jing Fan
- Shanghai Chengtou Water (Group) Co. LTD, Shanghai 200002, PR China
| | - Bing Geng
- Shanghai Chengtou Water (Group) Co. LTD, Shanghai 200002, PR China
| | - Bin Xu
- State Key Laboratory of Pollution Control and Resource Reuse, Key Laboratory of Urban Water Supply, Water Saving and Water Environment Governance in the Yangtze River Delta of Ministry of Water Resources, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, PR China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, PR China.
| |
Collapse
|
3
|
Zheng S, Li J, Ye C, Xian X, Feng M, Yu X. Microbiological risks increased by ammonia-oxidizing bacteria under global warming: The neglected issue in chloraminated drinking water distribution system. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 874:162353. [PMID: 36822432 DOI: 10.1016/j.scitotenv.2023.162353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/14/2023] [Accepted: 02/16/2023] [Indexed: 06/18/2023]
Abstract
A rising outbreak of waterborne diseases caused by global warming requires higher microbial stability in the drinking water distribution system (DWDS). Chloramine disinfection is gaining popularity in this context due to its good persistent stability and fewer disinfection byproducts. However, the microbiological risks may be significantly magnified by ammonia-oxidizing bacteria (AOB) in distribution systems during global warming, which is rarely noticed. Hence, this work mainly focuses on AOB to explore its impact on water quality biosafety in the context of global warming. Research indicates that global warming-induced high temperatures can directly or indirectly promote the growth of AOB, thus leading to nitrification. Further, its metabolites or cellular residues can be used as substrates for the growth of heterotrophic bacteria (e.g., waterborne pathogens). Thus, biofilm may be more persistent in the pipelines due to the presence of AOB. Breakpoint chlorination is usually applied to control such situations. However, switching between this strategy and chloramine disinfection would result in even more severe nitrification and other adverse effects. Based on the elevated microbiological risks in DWDS, the following aspects should be paid attention to in future research: (1) to understand the response of nitrifying bacteria to high temperatures and the possible association between AOB and pathogenic growth, (2) to reveal the mechanisms of AOB-mediated biofilm formation under high-temperature stress, and (3) to develop new technologies to prevent and control the occurrence of nitrification in drinking water distribution system.
Collapse
Affiliation(s)
- Shikan Zheng
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Jianguo Li
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Chengsong Ye
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Xuanxuan Xian
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Mingbao Feng
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China
| | - Xin Yu
- College of the Environment and Ecology, Xiamen University, Xiamen 361102, China.
| |
Collapse
|
4
|
Woo Y, Cruz MC, Wuertz S. Selective Enrichment of Nitrososphaera viennensis-Like Ammonia-Oxidizing Archaea over Ammonia-Oxidizing Bacteria from Drinking Water Biofilms. Microbiol Spectr 2022; 10:e0184522. [PMID: 36445127 PMCID: PMC9769795 DOI: 10.1128/spectrum.01845-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 11/08/2022] [Indexed: 12/03/2022] Open
Abstract
Ammonia-oxidizing archaea (AOA) can oxidize ammonia to nitrite for energy gain. They have been detected in chloraminated drinking water distribution systems (DWDS) along with the more common ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB). To date, no members of the AOA have been isolated or enriched from drinking water environments. To begin the investigation of the role of AOA in chloraminated DWDS, we developed a selective approach using biofilm samples from a full-scale operational network as inoculum. A Nitrososphaera viennensis-like AOA taxon was enriched from a mixed community that also included Nitrosomonas-like AOB while gradually scaling up the culture volume. Dimethylthiourea (DMTU) and pyruvate at 100 μM were added to promote the growth of AOA while inhibiting AOB. This resulted in the eventual washout of AOB, while NOB were absent after 2 or 3 rounds of amendment with 24 μM sodium azide. The relative abundance of AOA in the enrichment increased from 0.2% to 39.5% after adding DMTU and pyruvate, and further to 51.6% after filtration through a 0.45-μm pore size membrane, within a period of approximately 6 months. IMPORTANCE Chloramination has been known to increase the risk of nitrification episodes in DWDS due to the presence of ammonia-oxidizing microorganisms. Among them, AOB are more frequently detected than AOA. All publicly available cultures of AOA have been isolated from soil, marine or surface water environments, meaning they are allochthonous to DWDS. Hence, monochloramine exposure studies involving these strains may not accurately reflect their role in DWDS. The described method allows for the rapid enrichment of autochthonous AOA from drinking water nitrifying communities. The high relative abundance of AOA in the resulting enrichment culture reduces any confounding effects of co-existing heterotrophic bacteria when investigating the response of AOA to varied levels of monochloramine in drinking water.
Collapse
Affiliation(s)
- Yissue Woo
- Singapore Centre for Environmental Life Sciences Engineering, Nanyang Technological University, Singapore, Singapore
- Singapore Centre for Environmental Life Sciences Engineering, Interdisciplinary Graduate Programme, Nanyang Technological University, Singapore, Singapore
- School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, Singapore
| | - Mercedes Cecilia Cruz
- Singapore Centre for Environmental Life Sciences Engineering, Nanyang Technological University, Singapore, Singapore
| | - Stefan Wuertz
- Singapore Centre for Environmental Life Sciences Engineering, Nanyang Technological University, Singapore, Singapore
- School of Civil and Environmental Engineering, Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
5
|
Karthik NB, Bal Krishna KC, Sathasivan A. Factors controlling the effectiveness of rechlor(am)ination to recover chloramine from nitrification. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 806:151322. [PMID: 34743887 DOI: 10.1016/j.scitotenv.2021.151322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 10/24/2021] [Accepted: 10/26/2021] [Indexed: 06/13/2023]
Abstract
The two most commonly adopted strategies, rechlorination (addition of chlorine) and rechloramination (addition of chlorine and ammonia), to recover and stabilise chloramine from nitrification were comprehensively evaluated in laboratory- and full-scale systems. Laboratory-scale batch experiments were conducted in a nitrifying sample (~0.05 mg-N/L). In the full-scale service reservoir, repeated rechlorination was ineffective in suppressing nitrification and microbial chloramine decay during warmer months (>20 °C), even when rechlorination was started at nitrite <0.005 mg-N/L. Measurement of decay rates through microbial chloramine decay factor method provides a deeper understanding of a water sample than traditional nitrification indicators. The method has the ability to provide an early warning (one month in advance), show the presence of microbial chloramine decay in non-nitrified water and that of chloramine decaying proteins in any samples. In the batch sample, nitrification and the production of chloramine-decaying proteins and bacterial regrowth had to be suppressed to recover chloramine. Rechloramination (~2.5 mg/L) outperformed rechlorination, as it maintained a relatively higher chloramine concentration. Microbes were killed within 30 min of dosing chlor(am)ine, likely due to shock or compounds formed during chloramine formation reactions; however, microbes regrew (or survive) to a different degree in all samples despite the prolonged presence of chloramine (large CxT), defying the CxT concept. The key to the recovery of chloramine appears to be consistently maintaining chloramine >1.7 mg/L and shocking with a high chloramine dose. The findings will assist water utilities in designing and assessing the effectiveness of nitrification remediation strategies in chloraminated water supply systems.
Collapse
Affiliation(s)
- N B Karthik
- School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2750, Sydney, Australia
| | - K C Bal Krishna
- School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2750, Sydney, Australia
| | - Arumugam Sathasivan
- School of Engineering, Western Sydney University, Locked Bag 1797, Penrith, NSW 2750, Sydney, Australia.
| |
Collapse
|
6
|
Takahashi Y, Ishii K, Kikkawa Y, Horikiri K, Tsuneda S. Nitrite Production by Nitrifying Bacteria in Urban Groundwater Used in a Chlorinated Public Bath System in Japan. Microbes Environ 2022; 37:ME22040. [PMID: 36198516 PMCID: PMC9763042 DOI: 10.1264/jsme2.me22040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
In contrast to pathogens, the effects of environmental microbes on the water quality in baths have not yet been examined in detail. We herein focused on a public bath in which groundwater was pumped up as bath water and disinfected by chlorination. Ammonia in groundwater is oxidized to nitrite, thereby reducing residual chlorine. A batch-culture test and bacterial community ana-lysis revealed that ammonia-oxidizing bacteria accumulated nitrite and had higher resistance to chlorination than nitrite-oxidizing bacteria. These results demonstrate that the difference in resistance to chlorination between ammonia-oxidizing and nitrite-oxidizing bacteria may lead to the accumulation of nitrite in baths using groundwater.
Collapse
Affiliation(s)
- Yu Takahashi
- Department of Life Science and Medical Bioscience, School of Advanced Science and Engineering, Waseda University, 2–2 Wakamatsu-cho, Shinjuku-ku, Tokyo, 162–8480, Japan
| | - Kento Ishii
- Department of Life Science and Medical Bioscience, School of Advanced Science and Engineering, Waseda University, 2–2 Wakamatsu-cho, Shinjuku-ku, Tokyo, 162–8480, Japan
| | - Yukie Kikkawa
- Yokohama City Institute of Public Health, 2–7–1 Tomiokahigashi, Kanazawa-ku, Yokohama-shi, Kanagawa, 236–0051, Japan
| | - Kayo Horikiri
- Yokohama City Institute of Public Health, 2–7–1 Tomiokahigashi, Kanazawa-ku, Yokohama-shi, Kanagawa, 236–0051, Japan
| | - Satoshi Tsuneda
- Department of Life Science and Medical Bioscience, School of Advanced Science and Engineering, Waseda University, 2–2 Wakamatsu-cho, Shinjuku-ku, Tokyo, 162–8480, Japan, Corresponding author. E-mail: ; Tel: +81–3–5369–7325; Fax: +81–3–5369–7325
| |
Collapse
|
7
|
Keshvardoust P, Huron VAA, Clemson M, Barraud N, Rice SA. Nitrite production by ammonia-oxidizing bacteria mediates chloramine decay and resistance in a mixed-species community. Microb Biotechnol 2020; 13:1847-1859. [PMID: 32729670 PMCID: PMC7533321 DOI: 10.1111/1751-7915.13628] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Revised: 06/14/2020] [Accepted: 06/24/2020] [Indexed: 12/02/2022] Open
Abstract
As water distribution centres increasingly switch to using chloramine to disinfect drinking water, it is of paramount importance to determine the interactions of chloramine with potential biological contaminants, such as bacterial biofilms, that are found in these systems. For example, ammonia-oxidizing bacteria (AOB) are known to accelerate the decay of chloramine in drinking water systems, but it is also known that organic compounds can increase the chloramine demand. This study expanded upon our previously published model to compare the decay of chloramine in response to alginate, Pseudomonas aeruginosa, Nitrosomonas europaea and a mixed-species nitrifying culture, exploring the contributions of microbial by-products, heterotrophic bacteria and AOBs to chloramine decay. Furthermore, the contribution of AOBs to biofilm stability during chloramination was investigated. The results demonstrate that the biofilm matrix or extracellular polymeric substances (EPS), represented by alginate in these experiments, as well as high concentrations of dead or inactive cells, can drive chloramine decay rather than any specific biochemical activity of P. aeruginosa cells. Alginate was shown to reduce chloramine concentrations in a dose-dependent manner at an average rate of 0.003 mg l-1 h-1 per mg l-1 of alginate. Additionally, metabolically active AOBs mediated the decay of chloramine, which protected members of mixed-species biofilms from chloramine-mediated disinfection. Under these conditions, nitrite produced by AOBs directly reacted with chloramine to drive its decay. In contrast, biofilms of mixed-species communities that were dominated by heterotrophic bacteria due to either the absence of ammonia, or the addition of nitrification inhibitors and glucose, were highly sensitive to chloramine. These results suggest that mixed-species biofilms are protected by a combination of biofilm matrix-mediated inactivation of chloramine as well as the conversion of ammonia to nitrite through the activity of AOBs present in the community.
Collapse
Affiliation(s)
- Pejhman Keshvardoust
- The School of Biotechnology and Biomolecular SciencesThe University of New South WalesSydneyNSWAustralia
- The Centre for Marine Bio‐InnovationThe University of New South WalesSydneyNSWAustralia
| | - Vanessa A. A. Huron
- The School of Biotechnology and Biomolecular SciencesThe University of New South WalesSydneyNSWAustralia
- The Centre for Marine Bio‐InnovationThe University of New South WalesSydneyNSWAustralia
| | - Matthew Clemson
- The School of Biotechnology and Biomolecular SciencesThe University of New South WalesSydneyNSWAustralia
| | - Nicolas Barraud
- Genetics of Biofilms UnitDepartment of MicrobiologyInstitut PasteurParisFrance
| | - Scott A. Rice
- The Singapore Centre for Environmental Life Sciences Engineering and the School of Biological SciencesNanyang Technological UniversitySingapore
- Environmental SciencesThe University of New South WalesSydneyNSWAustralia
- ithree InstituteUniversity of Technology SydneySydneyNSWAustralia
| |
Collapse
|