Heines SJH, Becher TH, van der Horst ICC, Bergmans DCJJ. Clinical Applicability of Electrical Impedance Tomography in Patient-Tailored Ventilation: A Narrative Review. Tomography 2023; 9:1903-1932. [PMID: 37888742 PMCID: PMC10611090 DOI: 10.3390/tomography9050150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive bedside imaging technique that provides real-time lung ventilation information on critically ill patients. EIT can potentially become a valuable tool for optimising mechanical ventilation, especially in patients with acute respiratory distress syndrome (ARDS). In addition, EIT has been shown to improve the understanding of ventilation distribution and lung aeration, which can help tailor ventilatory strategies according to patient needs. Evidence from critically ill patients shows that EIT can reduce the duration of mechanical ventilation and prevent lung injury due to overdistension or collapse. EIT can also identify the presence of lung collapse or recruitment during a recruitment manoeuvre, which may guide further therapy. Despite its potential benefits, EIT has not yet been widely used in clinical practice. This may, in part, be due to the challenges associated with its implementation, including the need for specialised equipment and trained personnel and further validation of its usefulness in clinical settings. Nevertheless, ongoing research focuses on improving mechanical ventilation and clinical outcomes in critically ill patients.
Collapse
Affiliation(s)
- Serge J. H. Heines
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
| | - Tobias H. Becher
- Department of Anesthesiology and Intensive Care Medicine, Campus Kiel, University Medical Centre Schleswig-Holstein, 24118 Kiel, Germany;
| | - Iwan C. C. van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 HX Maastricht, The Netherlands
| | - Dennis C. J. J. Bergmans
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
2
|
Gao L, Zhu Y, Pan C, Yin Y, Zhao Z, Yang L, Zhang J. A randomised trial evaluating mask ventilation using electrical impedance tomography during anesthetic induction: one-handed technique versus two-handed technique. Physiol Meas 2022; 43. [PMID: 35580595 DOI: 10.1088/1361-6579/ac70a3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 05/17/2022] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Mask positive pressure ventilation could lead to inhomogeneity of lung ventilation, potentially inducing lung function impairments, when compared with spontaneous breathing. The inhomogeneity of lung ventilation can be monitored by chest electrical impedance tomography (EIT), which could increase our understanding of mask ventilation-derived respiratory mechanics. We hypothesized that two-handed mask holding ventilation technique had better lung ventilation reflected by respiratory mechanics when compared with one-handed mask holding technique. APPROACH Elective surgical patients with healthy lungs were randomly assigned to receive either one-handed mask holding (one-handed group) or two-handed mask holding (two-handed group) ventilation. Mask ventilation was performed by certified registered anesthesiologists, during which the patients were mechanically ventilated with pressure-controlled mode. EIT was used to assess respiratory mechanics including: ventilation distribution, global and regional respiratory system compliance (CRS), expiratory tidal volume (TVe) and minute ventilation volume. Besides, hemodynamic parameters and PaO2-FiO2-ratio were also recorded. MAIN RESULTS Eighty adult patients were included in this study. Compared with spontaneous ventilation, mask positive pressure ventilation caused inhomogeneity of lung ventilation in both one-handed group (global inhomogeneity index: 0.40±0.07 vs. 0.50±0.15; P<0.001) and two-handed group (0.40±0.08 vs. 0.50±0.13; P<0.001). There were no differences of global inhomogeneity index (P = 0.948) between the one-handed group and two-handed group. Compared with one-handed group, two-handed group was associated with higher TVe (552.6±184.2 ml vs. 672.9±156.6 ml, P=0.002) and higher global CRS (46.5±16.4 ml/cmH2O vs. 53.5±14.5 ml/cmH2O, P=0.049). No difference of PaO2-FiO2-ratio was found between two groups (P=0.743). SIGNIFICANCE The two-handed mask holding technique could not improve the inhomogeneity of lung ventilation when monitored by EIT during mask ventilation although it obtained larger expiratory tidal volumes than one-handed mask holding technique.
Collapse
Affiliation(s)
- Lingling Gao
- Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, Shanghai, 200032, CHINA
| | - Yun Zhu
- Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, Shanghai, 200032, CHINA
| | - Congxia Pan
- Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, Shanghai, 200032, CHINA
| | - Yuehao Yin
- Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, Shanghai, 200032, CHINA
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China, Xi'an, 710032, CHINA
| | - Li Yang
- Fudan University Shanghai Cancer Center, Department of Anesthesiology, Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, 200032, CHINA
| | - Jun Zhang
- Fudan University Shanghai Cancer Center, 270 Dong An Road, Xuhui, Shanghai, 200032, China, Shanghai, Shanghai, 200032, CHINA
| |
Collapse
|
3
|
Yang L, Dai M, Cao X, Möller K, Dargvainis M, Frerichs I, Becher T, Fu F, Zhao Z. Regional ventilation distribution in healthy lungs: can reference values be established for electrical impedance tomography parameters? ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:789. [PMID: 34268402 PMCID: PMC8246208 DOI: 10.21037/atm-20-7442] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Accepted: 01/24/2021] [Indexed: 12/26/2022]
Abstract
Background Although electrical impedance tomography (EIT) is widely used for monitoring regional ventilation distribution, reference values have yet to be established for clinical use. The present study aimed to evaluate the feasibility of creating reference values for standard EIT parameters for potential clinical application. Methods A total of 75 participants with healthy lungs were included in this prospective study (male:female, 48:27; age, 34±14 years; height, 172±7 cm; weight, 73±12 kg). The subjects were examined during spontaneous breathing in the supine position. EIT measurements were performed at the level of the 4th intercostal space. Commonly used EIT-based parameters, including the center of ventilation (CoV), dorsal and most dorsal fractions of ventilation distribution (TVD and TVROI4 respectively), global inhomogeneity (GI) index, and standard deviation of regional ventilation delay index (RVDSD) were calculated. Results Following outlier detection, EIT data from 71 subjects were finally evaluated. The values of the evaluated parameters were: CoV, 48.7%±1.7%; TVD, 48.1%±5.4%; TVROI4, 7.1%±1.8%; GI, 0.49±0.04; and RVDSD, 7.0±2.0. The coefficients of variation for CoV and GI were low (0.03 and 0.07, respectively), but those for TVROI4 and RVDSD were comparatively high (0.26 and 0.28, respectively). None of the evaluated parameters showed a significant correlation with age. The GI index showed a weak but significant correlation with body mass index (R=0.29, P=0.01). The RVDSD was slightly higher in males than in females. Conclusions Our study indicated that CoV and GI were stable parameters with small coefficients of variation in participants with healthy lungs. The creation of EIT parameter reference values for setting treatment targets may be feasible.
Collapse
Affiliation(s)
- Lin Yang
- Department of Aerospace Medicine, Fourth Military Medical University, Xi'an, China
| | - Meng Dai
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Xinsheng Cao
- Department of Aerospace Medicine, Fourth Military Medical University, Xi'an, China
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Mantas Dargvainis
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Tobias Becher
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre of Schleswig-Holstein Campus Kiel, Kiel, Germany
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, Xi'an, China.,Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|