Wahbah M, Zitouni MS, Al Sakaji R, Funamoto K, Widatalla N, Krishnan A, Kimura Y, Khandoker AH. A deep learning framework for noninvasive fetal ECG signal extraction. Front Physiol 2024; 15:1329313. [PMID: 38711954 PMCID: PMC11073781 DOI: 10.3389/fphys.2024.1329313] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 03/22/2024] [Indexed: 05/08/2024] Open
Abstract
Introduction: The availability of proactive techniques for health monitoring is essential to reducing fetal mortality and avoiding complications in fetal wellbeing. In harsh circumstances such as pandemics, earthquakes, and low-resource settings, the incompetence of many healthcare systems worldwide in providing essential services, especially for pregnant women, is critical. Being able to continuously monitor the fetus in hospitals and homes in a direct and fast manner is very important in such conditions. Methods: Monitoring the health of the baby can potentially be accomplished through the computation of vital bio-signal measures using a clear fetal electrocardiogram (ECG) signal. The aim of this study is to develop a framework to detect and identify the R-peaks of the fetal ECG directly from a 12 channel abdominal composite signal. Thus, signals were recorded noninvasively from 70 pregnant (healthy and with health conditions) women with no records of fetal abnormalities. The proposed model employs a recurrent neural network architecture to robustly detect the fetal ECG R-peaks. Results: To test the proposed framework, we performed both subject-dependent (5-fold cross-validation) and independent (leave-one-subject-out) tests. The proposed framework achieved average accuracy values of 94.2% and 88.8%, respectively. More specifically, the leave-one-subject-out test accuracy was 86.7% during the challenging period of vernix caseosa layer formation. Furthermore, we computed the fetal heart rate from the detected R-peaks, and the demonstrated results highlight the robustness of the proposed framework. Discussion: This work has the potential to cater to the critical industry of maternal and fetal healthcare as well as advance related applications.
Collapse
Affiliation(s)
- Maisam Wahbah
- College of Engineering and Information Technology, University of Dubai, Dubai, United Arab Emirates
- Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - M. Sami Zitouni
- College of Engineering and Information Technology, University of Dubai, Dubai, United Arab Emirates
| | - Raghad Al Sakaji
- Department of Industrial and Systems Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | | | - Namareq Widatalla
- Health Engineering Innovation Center (HEIC), Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Anita Krishnan
- Children’s National Hospital, Washington, DC, United States
| | | | - Ahsan H. Khandoker
- Health Engineering Innovation Center (HEIC), Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| |
Collapse
|
2
|
Mercado L, Escalona-Vargas D, Blossom S, Siegel ER, Whittington JR, Preissl H, Walden K, Eswaran H. The effect of maternal pregestational diabetes on fetal autonomic nervous system. Physiol Rep 2023; 11:e15680. [PMID: 37144450 PMCID: PMC10161040 DOI: 10.14814/phy2.15680] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2022] [Revised: 03/29/2023] [Accepted: 04/12/2023] [Indexed: 05/06/2023] Open
Abstract
Heart rate variability assessment of neonates of pregestational diabetic mothers have shown alterations in the autonomic nervous system (ANS). The objective was to study the effect of maternal pregestational diabetes on ANS at the fetal stage by combining cardiac and movement parameters using a non-invasive fetal magnetocardiography (fMCG) technique. This is an observational study with 40 participants where fetuses from a group of 9 Type 1, 19 Type 2 diabetic, and 12 non-diabetic pregnant women were included. Time and frequency domain fetal heart rate variability (fHRV) and coupling of movement and heart rate acceleration parameters related to fetal ANS were analyzed. Group differences were investigated using analysis of covariance to adjust for gestational age (GA). When compared to non-diabetics, the Type 1 diabetics had a 65% increase in average ratio of very low-frequency (VLF) to low-frequency (LF) bands and 63% average decrease in coupling index after adjusting for GA. Comparing Type 2 diabetics to non-diabetics, there was an average decrease in the VLF (50%) and LF bands (63%). Diabetics with poor glycemic control had a higher average VLF/LF (49%) than diabetics with good glycemic control. No significant changes at p < 0.05 were observed in high-frequency (HF) frequency domain parameters or their ratios, or in the time domain. Fetuses of pregestational diabetic mothers exhibited some differences in fHRV frequency domain and heart rate-movement coupling when compared to non-diabetics but the effect of fHRV related to fetal ANS and sympathovagal balance were not as conclusive as observed in the neonates of pregestational diabetic mothers.
Collapse
Affiliation(s)
- Luis Mercado
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Diana Escalona-Vargas
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
- Department of Pediatrics, University of Arkansas for Medical Sciences, Arkansas Children's Research Institute, Little Rock, Arkansas, USA
| | - Sarah Blossom
- Department of Pediatrics, University of Arkansas for Medical Sciences, Arkansas Children's Research Institute, Little Rock, Arkansas, USA
| | - Eric R Siegel
- Department of Biostatistics, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Julie R Whittington
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Hubert Preissl
- Institute for Diabetes Research and Metabolic Diseases of the Helmholtz Center Munich at the University of Tübingen, German Center for Diabetes Research (DZD), Tübingen, Germany
| | - Kaitlyn Walden
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | - Hari Eswaran
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| |
Collapse
|
3
|
Widatalla N, Khandoker A, Alkhodari M, Koide K, Yoshida C, Kasahara Y, Kimura Y, Saito M. Similarities between maternal and fetal RR interval tachograms and their association with fetal development. Front Physiol 2022; 13:964755. [PMID: 36479345 PMCID: PMC9721082 DOI: 10.3389/fphys.2022.964755] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Accepted: 11/02/2022] [Indexed: 12/26/2023] Open
Abstract
An association between maternal and fetal heart rate (HR) has been reported but, so far, little is known about its physiological implication and importance relative to fetal development. Associations between both HRs were investigated previously by performing beat-by-beat coupling analysis and correlation analysis between average maternal and fetal HRs. However, studies reporting on the presence of similarities between maternal and fetal HRs or RR intervals (RRIs) over the short term (e.g., 5-min) at different gestational ages (GAs) are scarce. Here, we demonstrate the presence of similarities in the variations exhibited by maternal and fetal RRl tachograms (RRITs). To quantify the same similarities, a cross-correlation (CC) analysis between resampled maternal and fetal RRITs was conducted; RRITs were obtained from non-invasive electrocardiogram (ECG). The degree of similarity between maternal and fetal RRITs (bmfRRITs) was quantified by calculating four CC coefficients. CC analysis was performed for a total of 330 segments (two 5-min segments from 158 subjects and one 5-min from 14 subjects). To investigate the association of the similarity bmfRRITs with fetal development, the linear correlation between the calculated CC coefficients and GA was calculated. The results from the latter analysis showed that similarities bmfRRITs are common occurrences, they can be negative or positive, and they increase with GA suggesting the presence of a regulation that is associated with proper fetal development. To get an insight into the physiological mechanisms involved in the similarity bmfRRITs, the association of the same similarity with maternal and fetal HR variability (HRV) was investigated by comparing the means of two groups in which one of them had higher CC values compared to the other. The two groups were created by using the data from the 158 subjects where fetal RRI (fRRI) calculation from two 5-min ECG segments was feasible. The results of the comparison showed that the maternal very low frequency (VLF) HRV parameter is potentially associated with the similarity bmfRRITs implying that maternal hormones could be linked to the regulations involved in the similarity bmfRRITs. Our findings in this study reinforce the role of the maternal intrauterine environment on fetal development.
Collapse
Affiliation(s)
- Namareq Widatalla
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Ahsan Khandoker
- Healthcare Engineering Innovation Center, Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Mohanad Alkhodari
- Healthcare Engineering Innovation Center, Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
- Cardiovascular Clinical Research Facility, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Kunihiro Koide
- Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Chihiro Yoshida
- Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Yoshiyuki Kasahara
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
- Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Yoshitaka Kimura
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
- Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Masatoshi Saito
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
- Tohoku University Graduate School of Medicine, Sendai, Japan
| |
Collapse
|
4
|
Characterizing the effect of demographics, cardiorespiratory factors, and inter-subject variation on maternal heart rate variability in pregnancy with statistical modeling: a retrospective observational analysis. Sci Rep 2022; 12:19305. [PMID: 36369252 PMCID: PMC9651120 DOI: 10.1038/s41598-022-21792-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 10/04/2022] [Indexed: 11/13/2022] Open
Abstract
Pregnancy complications are associated with insufficient adaptation of the maternal autonomic nervous system to the physiological demands of pregnancy. Consequently, assessing maternal heart rate variability (mHRV)-which reflects autonomic regulation-is a promising tool for detecting early deterioration in maternal health. However, before mHRV can be used to screen for complications, an understanding of the factors influencing mHRV during healthy pregnancy is needed. In this retrospective observational study, we develop regression models to unravel the effects of maternal demographics (age, body mass index (BMI), gestational age (GA), and parity), cardiorespiratory factors (heart rate and breathing rate), and inter-subject variation on mHRV. We develop these models using two datasets which are comprised of, respectively, single measurements in 290 healthy pregnant women and repeated measurements (median = 8) in 29 women with healthy pregnancies. Our most consequential finding is that between one-third and two-thirds of the variation in mHRV can be attributed to inter-subject variability. Additionally, median heart rate dominantly affects mHRV (p < 0.001), while BMI and parity have no effect. Moreover, we found that median breathing rate, age, and GA all impact mHRV (p < 0.05). These results suggest that personalized, long-term monitoring would be necessary for using mHRV for obstetric screening.
Collapse
|
5
|
Bester M, Joshi R, Mischi M, van Laar JOEH, Vullings R. Longitudinally Tracking Maternal Autonomic Modulation During Normal Pregnancy With Comprehensive Heart Rate Variability Analyses. Front Physiol 2022; 13:874684. [PMID: 35615673 PMCID: PMC9125027 DOI: 10.3389/fphys.2022.874684] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Accepted: 03/31/2022] [Indexed: 12/28/2022] Open
Abstract
Changes in the maternal autonomic nervous system are essential in facilitating the physiological changes that pregnancy necessitates. Insufficient autonomic adaptation is linked to complications such as hypertensive diseases of pregnancy. Consequently, tracking autonomic modulation during progressing pregnancy could allow for the early detection of emerging deteriorations in maternal health. Autonomic modulation can be longitudinally and unobtrusively monitored by assessing heart rate variability (HRV). Yet, changes in maternal HRV (mHRV) throughout pregnancy remain poorly understood. In previous studies, mHRV is typically assessed only once per trimester with standard HRV features. However, since gestational changes are complex and dynamic, assessing mHRV comprehensively and more frequently may better showcase the changing autonomic modulation over pregnancy. Subsequently, we longitudinally (median sessions = 8) assess mHRV in 29 healthy pregnancies with features that assess sympathetic and parasympathetic activity, as well as heart rate (HR) complexity, HR responsiveness and HR fragmentation. We find that vagal activity, HR complexity, HR responsiveness, and HR fragmentation significantly decrease. Their associated effect sizes are small, suggesting that the increasing demands of advancing gestation are well tolerated. Furthermore, we find a notable change in autonomic activity during the transition from the second to third trimester, highlighting the dynamic nature of changes in pregnancy. Lastly, while we saw the expected rise in mean HR with gestational age, we also observed increased autonomic deceleration activity, seemingly to counter this rising mean HR. These results are an important step towards gaining insights into gestational physiology as well as tracking maternal health via mHRV.
Collapse
Affiliation(s)
- Maretha Bester
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Patient Care and Monitoring, Philips Research, Eindhoven, Netherlands
- *Correspondence: Maretha Bester,
| | - Rohan Joshi
- Patient Care and Monitoring, Philips Research, Eindhoven, Netherlands
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Judith O. E. H. van Laar
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
- Department of Obstetrics and Gynecology, Máxima Medical Centrum, Veldhoven, Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
6
|
Schwartz N, Mhajna M, Moody HL, Zahar Y, Shkolnik K, Reches A, Lowery CL. Novel uterine contraction monitoring to enable remote, self-administered nonstress testing. Am J Obstet Gynecol 2022; 226:554.e1-554.e12. [PMID: 34762863 DOI: 10.1016/j.ajog.2021.11.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 10/28/2021] [Accepted: 11/01/2021] [Indexed: 12/31/2022]
Abstract
BACKGROUND The serial fetal monitoring recommended for women with high-risk pregnancies places a substantial burden on the patient, often disproportionately affecting underprivileged and rural populations. A telehealth solution that can empower pregnant women to obtain recommended fetal surveillance from the comfort of their own home has the potential to promote health equity and improve outcomes. We have previously validated a novel, wireless pregnancy monitor that can remotely capture fetal and maternal heart rates. However, such a device must also detect uterine contractions if it is to be used to robustly conduct remote nonstress tests. OBJECTIVE This study aimed to describe and validate a novel algorithm that uses biopotential and acoustic signals to noninvasively detect uterine contractions via a wireless pregnancy monitor. STUDY DESIGN A prospective, open-label, 2-center study evaluated simultaneous detection of uterine contractions by the wireless pregnancy monitor and an intrauterine pressure catheter in women carrying singleton pregnancies at ≥32 0/7 weeks' gestation who were in the first stage of labor (ClinicalTrials.gov Identifier: NCT03889405). The study consisted of a training phase and a validation phase. Simultaneous recordings from each device were passively acquired for 30 to 60 minutes. In a subset of the monitoring sessions in the validation phase, tocodynamometry was also deployed. Three maternal-fetal medicine specialists, blinded to the data source, identified and marked contractions in all modalities. The positive agreement and false-positive rates of both the wireless monitor and tocodynamometry were calculated and compared with that of the intrauterine pressure catheter. RESULTS A total of 118 participants were included, 40 in the training phase and 78 in the validation phase (of which 39 of 78 participants were monitored simultaneously by all 3 devices) at a mean gestational age of 38.6 weeks. In the training phase, the positive agreement for the wireless monitor was 88.4% (1440 of 1692 contractions), with a false-positive rate of 15.3% (260/1700). In the validation phase, using the refined and finalized algorithm, the positive agreement for the wireless pregnancy monitor was 84.8% (2722/3210), with a false-positive rate of 24.8% (897/3619). For the subgroup who were monitored only with the wireless monitor and intrauterine pressure catheter, the positive agreement was 89.0% (1191/1338), with a similar false-positive rate of 25.4% (406/1597). For the subgroup monitored by all 3 devices, the positive agreement for the wireless monitor was significantly better than for tocodynamometry (P<.0001), whereas the false-positive rate was significantly higher (P<.0001). Unlike tocodynamometry, whose positive agreement was significantly reduced in the group with obesity compared with the group with normal weight (P=.024), the positive agreement of the wireless monitor did not vary across the body mass index groups. CONCLUSION This novel method to noninvasively monitor uterine activity, via a wireless pregnancy monitoring device designed for self-administration at home, was more accurate than the commonly used tocodynamometry and unaffected by body mass index. Together with the previously reported remote fetal heart rate monitoring capabilities, this added ability to detect uterine contractions has created a complete telehealth solution for remote administration of nonstress tests.
Collapse
|
7
|
Zizzo AR, Kirkegaard I, Uldbjerg N, Hansen J, Mølgaard H. Towards better reliability in fetal heart rate variability using time domain and spectral domain analyses. A new method for assessing fetal neurological state? PLoS One 2022; 17:e0263272. [PMID: 35231034 PMCID: PMC8887753 DOI: 10.1371/journal.pone.0263272] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 01/14/2022] [Indexed: 11/18/2022] Open
Abstract
OBJECTIVES Fetal heart rate variability (FHRV) has shown potential in fetal surveillance. Therefore, we aimed to evaluate the reliability of time domain and spectral domain parameters based on non-invasive fetal electrocardiography (NI-FECG). METHOD NI-FECG, with a sampling frequency of 1 kHz, was obtained in 75 healthy, singleton pregnant women between gestational age (GA) 20+0 to 41+0. The recording was divided into a) heart rate pattern (HRP) and b) periods fulfilling certain criteria of stationarity of RR-intervals, termed stationary heart rate pattern (SHRP). Within each recording, the first and the last time series from each HRP with less than 5% artifact correction were analyzed and compared. Standard deviation of normal-to-normal RR-intervals (SDNN), root mean square of successive differences (RMSSD), high frequency power (HF-power), low frequency power (LF-power), and LF-power/HF-power were performed. A multivariate mixed model was used and acceptable reliability was defined as intraclass correlation coefficient (ICC) ≥ 0.80 and a coefficient of variation (CV) ≤ 15%. Based on these results, the CV and ICC were computed if the average of two to six time series was used. RESULTS For GA 28+0 to 34+6, SDNN and RMSSD exhibited acceptable reliability (CV < 15%; ICC > 90%), whereas GA 35+0 to 41+0and 20+0 to 27+6 showed higher CVs. Spectral domain parameters also showed high CVs However, by using the mean value of two to six time series, acceptable reliability in SDNN, RMSSD and HF-power from GA 28+0 was achieved. Stationarity of RR-intervals showed high influence on reliability and SHRP was superior to HRP, whereas the length of the time series showed minor influence. CONCLUSION Acceptable reliability seems achievable in SDNN, RMSSD and HF-power from gestational week 28. However, stationarity of RR-intervals should be considered when selecting time series for analyses.
Collapse
Affiliation(s)
- Anne Rahbek Zizzo
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus N, Denmark
- * E-mail:
| | - Ida Kirkegaard
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus N, Denmark
| | - Niels Uldbjerg
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus N, Denmark
| | - John Hansen
- Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Henning Mølgaard
- Department of Cardiology, Aarhus University Hospital, Aarhus N, Denmark
| |
Collapse
|
8
|
Rahbek Zizzo A, Kirkegaard I, From Reese C, Hansen J, Uldbjerg N, Mølgaard H. Fetal respiratory movements improve reliability of heart rate variability and suggest a coupling between fetal respiratory arrhythmia and vagal activity. Physiol Rep 2022; 10:e15224. [PMID: 35307959 PMCID: PMC8935276 DOI: 10.14814/phy2.15224] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 02/21/2022] [Indexed: 04/21/2023] Open
Abstract
Fetal heart rate variability (FHRV) reflects autonomic cardiac regulation. The autonomic nervous system constantly adjusts the heart rate to maintain homeostasis. By providing insight into the fetal autonomic state, FHRV has the potential to become an investigational and clinical instrument. However, the method needs standardization and the influence of fetal movements, including fetal respiratory movements, is not well explored. Therefore, in a highly standardized setting, the aim was to evaluate the association between fetal movements and fetal heart rate variability (FHRV) including their impact on reliability. Fetal heart rate was obtained by noninvasive fetal electrocardiography (NI-FECG) and fetal movements by simultaneous ultrasound scanning in 30 healthy singleton pregnant women on two occasions with a maximum interval of 7 days. The standard deviation of normal-to-normal RR-intervals (SDNN), root mean square of successive RR-interval differences (RMDDS), high-frequency power (HF-power), low-frequency power (LF-power), and LF/HF were measured. A multivariate mixed model was used and reliability was defined as acceptable by a coefficient of variance (CV) ≤15% and an intraclass correlation coefficient (ICC) ≥0.80. During time periods with fetal respiratory movements, the highest reliability was achieved. Intra- and inter-observer reliability measurements were very high (CV: 0-9%; ICC ≧ 0.86). Within the same recording, SDNN and RMSSD achieved acceptable reliability (CV: 14-15%; ICC ≧ 0.80). However, day-to-day reliability displayed high CV's. In time periods with fetal respiratory movements, as compared to periods with quiescence RMSSD and HF-power were higher (Ratio: 1.33-2.03) and LF/HF power lower (Ratio: 0.54). In periods with fetal body movements SDNN, RMSSD and HF-power were higher (Ratio: 1.27-1.65). In conclusion, time periods with fetal respiratory movements were associated with high reliability of FHRV analyses and the highest values of parameters supposed to represent vagal activity.
Collapse
Affiliation(s)
- Anne Rahbek Zizzo
- Department of Obstetrics and GynaecologyAarhus University HospitalAarhus NDenmark
| | - Ida Kirkegaard
- Department of Obstetrics and GynaecologyAarhus University HospitalAarhus NDenmark
| | - Camille From Reese
- Department of Obstetrics and GynaecologyAarhus University HospitalAarhus NDenmark
| | - John Hansen
- Department of Health Science and TechnologyAalborg UniversityAalborgDenmark
| | - Niels Uldbjerg
- Department of Obstetrics and GynaecologyAarhus University HospitalAarhus NDenmark
| | - Henning Mølgaard
- Department of CardiologyAarhus University HospitalAarhus NDenmark
| |
Collapse
|
9
|
Olmos-Ramírez RL, Peña-Castillo MÁ, Mendieta-Zerón H, Reyes-Lagos JJ. Uterine activity modifies the response of the fetal autonomic nervous system at preterm active labor. Front Endocrinol (Lausanne) 2022; 13:1056679. [PMID: 36714609 PMCID: PMC9882419 DOI: 10.3389/fendo.2022.1056679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 12/20/2022] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND The autonomic nervous system of preterm fetuses has a different level of maturity than term fetuses. Thus, their autonomic response to transient hypoxemia caused by uterine contractions in labor may differ. This study aims to compare the behavior of the fetal autonomic response to uterine contractions between preterm and term active labor using a novel time-frequency analysis of fetal heart rate variability (FHRV). METHODS We performed a case-control study using fetal R-R and uterine activity time series obtained by abdominal electrical recordings from 18 women in active preterm labor (32-36 weeks of gestation) and 19 in active term labor (39-40 weeks of gestation). We analyzed 20 minutes of the fetal R-R time series by applying a Continuous Wavelet Transform (CWT) to obtain frequency (HF, 0.2-1 Hz; LF, 0.05-0.2 Hz) and time-frequency (Flux0, Flux90, and Flux45) domain features. Time domain FHRV features (SDNN, RMSSD, meanNN) were also calculated. In addition, ultra-short FHRV analysis was performed by segmenting the fetal R-R time series according to episodes of the uterine contraction and quiescent periods. RESULTS No significant differences between preterm and term labor were found for FHRV features when calculated over 20 minutes. However, we found significant differences when segmenting between uterine contraction and quiescent periods. In the preterm group, the LF, Flux0, and Flux45 were higher during the average contraction episode compared with the average quiescent period (p<0.01), while in term fetuses, vagally mediated FHRV features (HF and RMSSD) were higher during the average contraction episode (p<0.05). The meanNN was lower during the strongest contraction in preterm fetuses compared to their consecutive quiescent period (p=0.008). CONCLUSION The average autonomic response to contractions in preterm fetuses shows sympathetic predominance, while term fetuses respond through parasympathetic activity. Comparison between groups during the strongest contraction showed a diminished fetal autonomic response in the preterm group. Thus, separating contraction and quiescent periods during labor allows for identifying differences in the autonomic nervous system cardiac regulation between preterm and term fetuses.
Collapse
Affiliation(s)
- Rocio Lizbeth Olmos-Ramírez
- Basic Sciences and Engineering Division, Metropolitan Autonomous University (UAM) Campus Iztapalapa, Mexico City, Mexico
| | - Miguel Ángel Peña-Castillo
- Basic Sciences and Engineering Division, Metropolitan Autonomous University (UAM) Campus Iztapalapa, Mexico City, Mexico
| | - Hugo Mendieta-Zerón
- Health Institute of the State of Mexico (ISEM), "Mónica Pretelini Sáenz" Maternal-Perinatal Hospital, Toluca, Mexico
- School of Medicine, Autonomous University of the State of Mexico (UAEMéx), Toluca, Mexico
| | | |
Collapse
|
10
|
Widatalla N, Khandoker A, Yoshida C, Nakanishi K, Fukase M, Suzuki A, Saito M, Kimura Y, Kasahara Y. Correlation between maternal and fetal heart rate increases with fetal mouse age in typical development and is disturbed in autism mouse model treated with valproic acid. Front Psychiatry 2022; 13:998695. [PMID: 36518366 PMCID: PMC9743798 DOI: 10.3389/fpsyt.2022.998695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 11/07/2022] [Indexed: 11/25/2022] Open
Abstract
INTRODUCTION Autism spectrum disorder (ASD) is considered a significant behavioral problem that is characterized by impairment in social interaction and communication. It is believed that some cases of ASD originate in the intrauterine maternal environment. Therefore, we hypothesized that there might be qualitative changes in the interaction between the mother and fetus in ASD during the prenatal period, hence, we investigated the similarity patterns between maternal and fetal heart rate (HR). METHODS In this study, we first demonstrate the presence and formation of similarities between maternal and fetal RR interval (RRI) collected from typical developmental mice at different embryonic days (EDs), ED13.5, ED15.5, ED17.5, and ED18.5. The similarities were quantified by means of cross-correlation (CC) and magnitude-squared coherence (MSC) analyses. Correlation analysis between the CC coefficients and EDs and between MSC coefficients and EDs showed that the same coefficients increase with EDs, suggesting that similarities between maternal and fetal RRI are associated with typical fetal development. Next, because maternal and fetal similarities were indicative of development, a comparison analysis between the autism mouse model (injected with valproic acid (VPA)), and the control group (injected with saline) was performed for ED15.5 and ED18.5. RESULTS The results of the comparison showed that the CC and MSC coefficients of VPA fetuses were significantly lower than that of the control group. The lower coefficients in VPA-treated mice suggest that they could be one of the features of ASD symptoms. The findings of this study can assist in identifying potential ASD causes during the prenatal period.
Collapse
Affiliation(s)
- Namareq Widatalla
- Next Generation Biological Information Technology, Tohoku University Graduate School of Biomedical Engineering, Sendai, Japan
| | - Ahsan Khandoker
- Healthcare Engineering Innovation Center, Department of Biomedical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates
| | - Chihiro Yoshida
- Department of Maternal and Fetal Therapeutics, Tohoku University Graduate School of Medicine, Sendai, Japan.,Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Kana Nakanishi
- Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Miyabi Fukase
- Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Arisa Suzuki
- Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Masatoshi Saito
- Next Generation Biological Information Technology, Tohoku University Graduate School of Biomedical Engineering, Sendai, Japan.,Department of Maternal and Fetal Therapeutics, Tohoku University Graduate School of Medicine, Sendai, Japan.,Department of Maternal and Child Health Care Medical Science, Tohoku University Graduate School of Medicine, Sendai, Japan.,Department of Obstetrics and Gynecology, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Yoshitaka Kimura
- Next Generation Biological Information Technology, Tohoku University Graduate School of Biomedical Engineering, Sendai, Japan.,Department of Maternal and Fetal Therapeutics, Tohoku University Graduate School of Medicine, Sendai, Japan.,Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan
| | - Yoshiyuki Kasahara
- Next Generation Biological Information Technology, Tohoku University Graduate School of Biomedical Engineering, Sendai, Japan.,Department of Maternal and Fetal Therapeutics, Tohoku University Graduate School of Medicine, Sendai, Japan.,Advanced Interdisciplinary Biomedical Engineering, Tohoku University Graduate School of Medicine, Sendai, Japan.,Department of Maternal and Child Health Care Medical Science, Tohoku University Graduate School of Medicine, Sendai, Japan
| |
Collapse
|
11
|
Lempersz C, Noben L, Clur SAB, van den Heuvel E, Zhan Z, Haak M, Oei SG, Vullings R, van Laar JOEH. The electrical heart axis of the fetus between 18 and 24 weeks of gestation: A cohort study. PLoS One 2021; 16:e0256115. [PMID: 34914710 PMCID: PMC8675734 DOI: 10.1371/journal.pone.0256115] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 07/31/2021] [Indexed: 11/18/2022] Open
Abstract
Introduction A fetal anomaly scan in mid-pregnancy is performed, to check for the presence of congenital anomalies, including congenital heart disease (CHD). Unfortunately, 40% of CHD is still missed. The combined use of ultrasound and electrocardiography might boost detection rates. The electrical heart axis is one of the characteristics which can be deduced from an electrocardiogram (ECG). The aim of this study was to determine reference values for the electrical heart axis in healthy fetuses around 20 weeks of gestation. Material and methods Non-invasive fetal electrocardiography was performed subsequent to the fetal anomaly scan in pregnant women carrying a healthy singleton fetus between 18 and 24 weeks of gestation. Eight adhesive electrodes were applied on the maternal abdomen including one ground and one reference electrode, yielding six channels of bipolar electrophysiological measurements. After removal of interferences, a fetal vectorcardiogram was calculated and then corrected for fetal orientation. The orientation of the electrical heart axis was determined from this normalized fetal vectorcardiogram. Descriptive statistics were used on normalized cartesian coordinates to determine the average electrical heart axis in the frontal plane. Furthermore, 90% prediction intervals (PI) for abnormality were calculated. Results Of the 328 fetal ECGs performed, 281 were included in the analysis. The average electrical heart axis in the frontal plane was determined at 122.7° (90% PI: -25.6°; 270.9°). Discussion The average electrical heart axis of healthy fetuses around mid-gestation is oriented to the right, which is, due to the unique fetal circulation, in line with muscle distribution in the fetal heart.
Collapse
Affiliation(s)
- Carlijn Lempersz
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands
| | - Lore Noben
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands
| | - Sally-Ann B Clur
- Department of Pediatric Cardiology, Amsterdam University Medical Center, Amsterdam, The Netherlands
| | - Edwin van den Heuvel
- Department of Mathematics and Computer Science, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Zhouzhao Zhan
- Department of Mathematics and Computer Science, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Monique Haak
- Department of Obstetrics and Gynecology, Leiden University Medical Center, Leiden, The Netherlands
| | - S Guid Oei
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands.,Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Judith O E H van Laar
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, The Netherlands.,Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
12
|
Zwanenburg F, Jongbloed MRM, van Geloven N, Ten Harkel ADJ, van Lith JMM, Haak MC. Assessment of human fetal cardiac autonomic nervous system development using color tissue Doppler imaging. Echocardiography 2021; 38:974-981. [PMID: 34018638 PMCID: PMC8252470 DOI: 10.1111/echo.15094] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Revised: 04/20/2021] [Accepted: 04/28/2021] [Indexed: 12/14/2022] Open
Abstract
Objectives Functional development of the fetal cardiac autonomic nervous system (cANS) plays a key role in fetal maturation and can be assessed through fetal heart rate variability (fHRV)‐analysis, with each HRV parameter representing different aspects of cANS activity. Current available techniques, however, are unable to assess the fHRV parameters accurately throughout the whole pregnancy. This study aims to test the feasibility of color tissue Doppler imaging (cTDI) as a new ultrasound technique for HRV analysis. Secondly, we explored time trends of fHRV parameters using this technique. Methods 18 healthy singleton fetuses were examined sequentially every 8 weeks from 10 weeks GA onwards. From each examination, 3 cTDI recordings of the four‐chamber view of 10 seconds were retrieved to determine accurate beat‐to‐beat intervals. The fHRV parameters SDNN, RMSSD, SDNN/RMSSD, and pNN10, each representing different functional aspects of the cANS, were measured, and time trends during pregnancy were explored using spline functions within a linear mixed‐effects model. Results In total, 77% (95% Cl 66–87%) of examinations were feasible for fHRV analysis from the first trimester onwards, which is a great improvement compared to other techniques. The technique is able to determine different maturation rates of the fHRV parameters, showing that cANS function, presumably parasympathetic activity, establishes around 20 weeks GA and matures rapidly until 30 weeks GA. Conclusions This is the first study able to assess cANS function through fHRV analysis from the first trimester onwards. The use of cTDI to determine beat‐to‐beat intervals seems feasible in just 3 clips of 10 seconds, which holds promise for future clinical use in assessing fetal well‐being.
Collapse
Affiliation(s)
- Fleur Zwanenburg
- Department of Obstetrics and Prenatal Diagnosis, Leiden University Medical Center, Leiden, The Netherlands
| | - Monique R M Jongbloed
- Department of Cardiology, Leiden University Medical Center, Leiden, the Netherlands.,Department of Anatomy & Embryology, Leiden University Medical Center, Leiden, the Netherlands
| | - Nan van Geloven
- Department of Biomedical Data Sciences, Section Medical Statistics, Leiden University Medical Center, Leiden, The Netherlands
| | - Arend D J Ten Harkel
- Department of Pediatric Cardiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jan M M van Lith
- Department of Obstetrics and Prenatal Diagnosis, Leiden University Medical Center, Leiden, The Netherlands
| | - Monique C Haak
- Department of Obstetrics and Prenatal Diagnosis, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
13
|
Zizzo AR, Kirkegaard I, Hansen J, Uldbjerg N, Mølgaard H. Fetal Heart Rate Variability Is Affected by Fetal Movements: A Systematic Review. Front Physiol 2020; 11:578898. [PMID: 33101059 PMCID: PMC7554531 DOI: 10.3389/fphys.2020.578898] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 08/25/2020] [Indexed: 11/13/2022] Open
Abstract
Introduction: Fetal heart rate variability (FHRV) evaluates the fetal neurological state, which is poorly assessed by conventional prenatal surveillance including cardiotocography (CTG). Accurate FHRV on a beat-to-beat basis, assessed by time domain and spectral domain analyses, has shown promising results in the scope of fetal surveillance. However, accepted standards for these techniques are lacking, and the influence of fetal breathing movements and gross movements may be especially challenging. Thus, current standards for equivalent assessments in adults prescribe rest and controlled respiration. The aim of this review is to clarify the importance of fetal movements on FHRV. Methods: A systematic review in accordance with the PRISMA guidelines based on publications in the EMBASE, the MEDLINE, and the Cochrane Library databases was performed. Studies describing the impact of fetal movements on time domain, spectral domain and entropy analyses in healthy human fetuses were reviewed. Only studies based on fetal electrocardiography or fetal magnetocardiography were included. PROSPERO registration number: CRD42018068806. Results: In total, 14 observational studies were included. Fetal movement detection, signal processing, length, and selection of appropriate time series varied across studies. Despite these divergences, all studies showed an increase in overall FHRV in the moving fetus compared to the resting fetus. Especially short-term, vagal mediated indexes showed an increase during fetal breathing movements including an increase in Root Mean Square of the Successive Differences (RMSSD) and High Frequency power (HF) and a decrease in Low Frequency power/High Frequency power (LF/HF). These findings were present even in analyses restricted to one specific fetal behavioral state defined by Nijhuis. On the other hand, fetal body movements seemed to increase parameters supposed to represent the sympathetic response [LF and Standard Deviation of RR-intervals from normal sinus beats (SDNN)] proportionally more than parameters representing the parasympathetic response (RMSSD, HF). Results regarding entropy analyses were inconclusive. Conclusion: Time domain analyses as well as spectral domain analyses are affected by fetal movements. Fetal movements and especially breathing movements should be considered in these analyses of FHRV.
Collapse
Affiliation(s)
- Anne Rahbek Zizzo
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus, Denmark
| | - Ida Kirkegaard
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus, Denmark
| | - John Hansen
- Department of Health Science and Technology, Aalborg University, Aalborg, Denmark
| | - Niels Uldbjerg
- Department of Obstetrics and Gynecology, Aarhus University Hospital, Aarhus, Denmark
| | - Henning Mølgaard
- Department of Cardiology, Aarhus University Hospital, Aarhus, Denmark
| |
Collapse
|
14
|
Noben L, Westerhuis MEMH, van Laar JOEH, Kok RD, Oei SG, Peters CHL, Vullings R. Feasibility of non-invasive Foetal electrocardiography in a twin pregnancy. BMC Pregnancy Childbirth 2020; 20:215. [PMID: 32293330 PMCID: PMC7161133 DOI: 10.1186/s12884-020-02918-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2019] [Accepted: 04/01/2020] [Indexed: 11/21/2022] Open
Abstract
Background Twin pregnancy is associated with increased perinatal mortality. Close foetal monitoring is therefore warranted. Doppler Ultrasound cardiotocography is currently the only available method to monitor both individual foetuses. Unfortunately, the performance measures of this method are poor and erroneous monitoring of the same twin with both transducers may occur, leaving the second twin unmonitored. In this study we aimed to determine the feasibility of monitoring both foetuses simultaneously in twin gestation by means of non-invasive foetal electrocardiography (NI-fECG), using an electrode patch on the maternal abdomen. Methods A NI-fECG recording was performed at 25 + 3 weeks of gestation on a multiparous woman pregnant with dichorionic diamniotic twins. An electrode patch consisting of eight adhesive electrodes was applied on the maternal abdomen, yielding six channels of bipolar electrophysiological measurements. The output was digitized and stored for offline processing. The recorded signals were preprocessed by suppression of high-frequency noise, baseline wander, and powerline interference. Secondly, the maternal ECG was subtracted and segmentation into individual ECG complexes was performed. Finally, ensemble averaging of these individual ECG complexes was performed to suppress interferences. Results Six different recordings were obtained from each of the six recording channels. Depending on the orientation and distance of the fetal heart with respect to each electrode, a distinction could be made between each fetus based on the morphology of the signals. Yielding of the fetal ECGs was performed manually based on the QRS complexes of each fetus. Conclusion NI-fECG with multiple electrodes allows for monitoring of the fetal heart rate and ECG of both individual fetuses in twin pregnancies.
Collapse
Affiliation(s)
- Lore Noben
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands. .,Eindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.
| | - Michelle E M H Westerhuis
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - Judith O E H van Laar
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - René D Kok
- Nemo Healthcare BV, 'MMC Incubator', De Run 4630, 5504, DB, Veldhoven, The Netherlands
| | - S Guid Oei
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. Box 7777, 5500, MB, Veldhoven, The Netherlands.,Eindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| | - Chris H L Peters
- Department of Clinical Physics, Jeroen Bosch Hospital, P.O. Box 90153, 5200 ME, 's Hertogenbosch, The Netherlands
| | - Rik Vullings
- Eindhoven MedTech Innovation Centre (e/MTIC), P.O. Box 513, 5600, MB, Eindhoven, The Netherlands.,Department of Electrical Engineering, Eindhoven University of Technology, P.O. Box 513, 5600, MB, Eindhoven, The Netherlands
| |
Collapse
|
15
|
Fotiadou E, Konopczyński T, Hesser J, Vullings R. End-to-end trained encoder-decoder convolutional neural network for fetal electrocardiogram signal denoising. Physiol Meas 2020; 41:015005. [PMID: 31918422 DOI: 10.1088/1361-6579/ab69b9] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
OBJECTIVE Non-invasive fetal electrocardiography has the potential to provide vital information for evaluating the health status of the fetus. However, the low signal-to-noise ratio of the fetal electrocardiogram (ECG) impedes the applicability of the method in clinical practice. Quality improvement of the fetal ECG is of great importance for providing accurate information to enable support in medical decision-making. In this paper we propose the use of artificial intelligence for the task of one-channel fetal ECG enhancement as a post-processing step after maternal ECG suppression. APPROACH We propose a deep fully convolutional encoder-decoder framework, learning end-to-end mappings from noise-contaminated fetal ECGs to clean ones. Symmetric skip-layer connections are used between corresponding convolutional and transposed convolutional layers to help recover the signal details. MAIN RESULTS Experiments on synthetic data show an average improvement of 7.5 dB in the signal-to-noise ratio (SNR) for input SNRs in the range of -15 to 15 dB. Application of the method with real signals and subsequent ECG interval analysis demonstrates a root mean square error of 9.9 and 14 ms for the PR and QT intervals, respectively, when compared with simultaneous scalp measurements. The proposed network can achieve substantial noise removal on both synthetic and real data. In cases of highly noise-contaminated signals some morphological features might be unreliably reconstructed. SIGNIFICANCE The presented method has the advantage of preserving individual variations in pulse shape and beat-to-beat intervals. Moreover, no prior knowledge on the power spectra of the noise or the pulse locations is required.
Collapse
Affiliation(s)
- Eleni Fotiadou
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven 5612 AP, The Netherlands
| | | | | | | |
Collapse
|
16
|
Fotiadou E, Vullings R. Multi-Channel Fetal ECG Denoising With Deep Convolutional Neural Networks. Front Pediatr 2020; 8:508. [PMID: 32984218 PMCID: PMC7480014 DOI: 10.3389/fped.2020.00508] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 07/17/2020] [Indexed: 11/13/2022] Open
Abstract
Non-invasive fetal electrocardiography represents a valuable alternative continuous fetal monitoring method that has recently received considerable attention in assessing fetal health. However, the non-invasive fetal electrocardiogram (ECG) is typically severely contaminated by a considerable amount of various noise sources, rendering fetal ECG denoising a very challenging task. This work employs a deep learning approach for removing the residual noise from multi-channel fetal ECG after the maternal ECG has been suppressed. We propose a deep convolutional encoder-decoder network with symmetric skip-layer connections, learning end-to-end mappings from noise-corrupted fetal ECG signals to clean ones. Experiments on simulated data show an average signal-to-noise ratio (SNR) improvement of 9.5 dB for fetal ECG signals with input SNR ranging between -20 and 20 dB. The method is additionally evaluated on a large set of real signals, demonstrating that it can provide significant quality improvement of the noisy fetal ECG signals. We further show that employment of multi-channel signal information by the network provides superior and more reliable performance as opposed to its single-channel network counterpart. The presented method is able to preserve beat-to-beat morphological variations and does not require any prior information on the power spectra of the noise or the pulse location.
Collapse
Affiliation(s)
- Eleni Fotiadou
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| |
Collapse
|
17
|
Kahankova R, Martinek R, Jaros R, Behbehani K, Matonia A, Jezewski M, Behar JA. A Review of Signal Processing Techniques for Non-Invasive Fetal Electrocardiography. IEEE Rev Biomed Eng 2019; 13:51-73. [PMID: 31478873 DOI: 10.1109/rbme.2019.2938061] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Fetal electrocardiography (fECG) is a promising alternative to cardiotocography continuous fetal monitoring. Robust extraction of the fetal signal from the abdominal mixture of maternal and fetal electrocardiograms presents the greatest challenge to effective fECG monitoring. This is mainly due to the low amplitude of the fetal versus maternal electrocardiogram and to the non-stationarity of the recorded signals. In this review, we highlight key developments in advanced signal processing algorithms for non-invasive fECG extraction and the available open access resources (databases and source code). In particular, we highlight the advantages and limitations of these algorithms as well as key parameters that must be set to ensure their optimal performance. Improving or combining the current or developing new advanced signal processing methods may enable morphological analysis of the fetal electrocardiogram, which today is only possible using the invasive scalp electrocardiography method.
Collapse
|
18
|
Noben L, Clur SA, van Laar JO, Vullings R. Prenatal diagnosis of a bundle branch block based on the fetal ECG. BMJ Case Rep 2019; 12:12/7/e229998. [PMID: 31266761 DOI: 10.1136/bcr-2019-229998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
A non-invasive fetal ECG was performed on a 36-year-old pregnant woman at 24+6 weeks of gestation as part of ongoing clinical research. A paediatric cardiologist suspected an incomplete bundle branch block based on the averaged ECGs from the recording. The characteristic terminal R' wave was present in multiple leads of the fetal ECGs. A fetal anomaly scan had been performed at 20 weeks of gestation and showed no abnormalities. An incomplete right bundle branch block was confirmed on an ECG recorded at the age of 2 years. This case shows the possibility of novel non-invasive fetal ECG technology as an adjunct to the diagnosis of fetal cardiac anomalies in the future.
Collapse
Affiliation(s)
- Lore Noben
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, The Netherlands
| | - Sally-Ann Clur
- Department of Pediatric Cardiology, Emma Children's Hospital AMC, Amsterdam, The Netherlands
| | - Judith Oeh van Laar
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
19
|
Hamelmann P, Mischi M, Kolen AF, van Laar JOEH, Vullings R, Bergmans JWM. Fetal Heart Rate Monitoring Implemented by Dynamic Adaptation of Transmission Power of a Flexible Ultrasound Transducer Array. SENSORS (BASEL, SWITZERLAND) 2019; 19:E1195. [PMID: 30857218 PMCID: PMC6427711 DOI: 10.3390/s19051195] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 02/28/2019] [Accepted: 03/04/2019] [Indexed: 11/16/2022]
Abstract
Fetal heart rate (fHR) monitoring using Doppler Ultrasound (US) is a standard method to assess fetal health before and during labor. Typically, an US transducer is positioned on the maternal abdomen and directed towards the fetal heart. Due to fetal movement or displacement of the transducer, the relative fetal heart location (fHL) with respect to the US transducer can change, leading to frequent periods of signal loss. Consequently, frequent repositioning of the US transducer is required, which is a cumbersome task affecting clinical workflow. In this research, a new flexible US transducer array is proposed which allows for measuring the fHR independently of the fHL. In addition, a method for dynamic adaptation of the transmission power of this array is introduced with the aim of reducing the total acoustic dose transmitted to the fetus and the associated power consumption, which is an important requirement for application in an ambulatory setting. The method is evaluated using an in-vitro setup of a beating chicken heart. We demonstrate that the signal quality of the Doppler signal acquired with the proposed method is comparable to that of a standard, clinical US transducer. At the same time, our transducer array is able to measure the fHR for varying fHL while only using 50% of the total transmission power of standard, clinical US transducers.
Collapse
Affiliation(s)
- Paul Hamelmann
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands.
| | - Massimo Mischi
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands.
| | | | | | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands.
| | - Jan W M Bergmans
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, The Netherlands.
| |
Collapse
|
20
|
Noben L, Verdurmen KMJ, Warmerdam GJJ, Vullings R, Oei SG, van Laar JOEH. The fetal electrocardiogram to detect the effects of betamethasone on fetal heart rate variability. Early Hum Dev 2019; 130:57-64. [PMID: 30677639 DOI: 10.1016/j.earlhumdev.2019.01.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Revised: 01/15/2019] [Accepted: 01/15/2019] [Indexed: 10/27/2022]
Abstract
BACKGROUND Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm birth. Antenatal corticosteroids are known to reduce fetal heart rate variability (fHRV) in the days following administration. Since decreased fHRV is a marker for fetal distress, this transient decrease of fHRV can cause unnecessary medical intervention. AIM To describe the effect of betamethasone on fHRV, by applying spectral analysis on non-invasive fetal electrocardiogram (fECG) recordings. STUDY DESIGN Secondary analysis of a prospective cohort study. SUBJECTS Women with a singleton pregnancy, at risk for preterm delivery and receiving betamethasone, admitted to the obstetric high care unit in the period from March 2013 until July 2016. OUTCOME MEASURES The primary outcome measure was fHRV in both time- and frequency-domain. Secondary outcome measures included basal fetal heart rate (fHR) and fHR variance. FHRV parameters were then calculated separately for the quiet and active state. RESULTS Following 68 inclusions, 22 patients remained with complete series of measurements and sufficient data quality. FHRV parameters and fHR showed a decrease on day 2 compared to day 1, significant for short-term variability and high-frequency power. Similar results were found when analyzing for separate behavioral states. The number of segments in quiet state increased during days 1 and 2. Normalized values showed no difference for all behavioral states. CONCLUSION FHRV decreases on day 2 after betamethasone administration, while periods of fetal quiescence increase. No changes were found in the normalized values, indicating that the influence of autonomic modulation is minor. Clinical trial registration number NL43294.015.13.
Collapse
Affiliation(s)
- L Noben
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands.
| | - K M J Verdurmen
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - G J J Warmerdam
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - R Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| | - S G Oei
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - J O E H van Laar
- Department of Obstetrics and Gynecology, Maxima Medical Center, Veldhoven, the Netherlands; Eindhoven MedTech Innovation Center (e/MTIC), Eindhoven, the Netherlands
| |
Collapse
|
21
|
Kapaya H, Dimelow ER, Anumba D. Women's experience of wearing a portable fetal-electrocardiogram device to monitor small-for-gestational age fetus in their home environment. ACTA ACUST UNITED AC 2019; 14:1745506518785620. [PMID: 29968515 PMCID: PMC6048658 DOI: 10.1177/1745506518785620] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Objective: To determine the acceptability, to women, of wearing a portable fetal
electrocardiogram recording device at different stages of pregnancy and to
gain insight into their experience of its use for long-periods of monitoring
of small-for-gestational fetuses in the home environment. Methods: A qualitative study using both a questionnaire and focus group involving
women with singleton pregnancy >24 weeks gestation, no evidence of fetal
malformation and an estimated fetal weight below 10th gestational centile on
ultrasound scan. Fetal heart rate recordings were collected for up to
20 h. Results: In total, 59 questionnaires were completed; 35 after wearing the monitor for
the first time and an additional 24 from the women who wore the device for a
second time. Six women participated in the focus group; the principal theme
identified related to the practicality of the fetal electrocardiogram
device. Other themes identified were the discomfort that resulted from
wearing the monitor and the reassurance provided in knowing that the baby’s
heart rate was being monitored. Conclusion: Long-term ambulatory fetal electrocardiogram monitoring is an acceptable
method of monitoring small-for-gestational fetuses. Overall, women concluded
that benefits of wearing the device outweighed any discomfort it caused.
Collapse
Affiliation(s)
- Habiba Kapaya
- 1 Academic Unit of Reproductive & Developmental Medicine, Department of Oncology & Metabolism, The University of Sheffield, Sheffield, UK
| | | | - Dilly Anumba
- 1 Academic Unit of Reproductive & Developmental Medicine, Department of Oncology & Metabolism, The University of Sheffield, Sheffield, UK
| |
Collapse
|
22
|
Sletten J, Lund A, Ebbing C, Cornelissen G, Aßmus J, Kiserud T, Albrechtsen S, Kessler J. The fetal circadian rhythm in pregnancies complicated by pregestational diabetes is altered by maternal glycemic control and the morning cortisol concentration. Chronobiol Int 2019; 36:481-492. [PMID: 30621462 DOI: 10.1080/07420528.2018.1561460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Circadian rhythmicity is fundamental to human physiology, and is present even during fetal life in normal pregnancies. The impact of maternal endocrine disease on the fetal circadian rhythm is not well understood. The present study aimed to determine the fetal circadian rhythm in pregnancies complicated by pregestational diabetes mellitus (PGDM), compare it with a low-risk reference population, and identify the effects of maternal glycemic control and morning cortisol concentrations. Long-term fetal electrocardiogram recordings were made in 40 women with PGDM at 28 and 36 weeks of gestation. Two recordings were made in 18 of the women (45.0%) and one recording was made in 22 (55.0%). The mean fetal heart rate (fHR) and the fHR variation (root mean square of squared differences) were extracted in 1-min epochs, and circadian rhythmicity was detected by cosinor analysis. The study cohort was divided based on HbA1c levels and morning cortisol concentrations. Statistically, significant circadian rhythms in the fHR and the fHR variation were found in 45 (100%) and 44 (95.7%) of the 45 acceptable PGDM recordings, respectively. The rhythms were similar to those of the reference population. However, there was no statistically significant population-mean rhythm in the fHR among PGDM pregnancies at 36 weeks, indicating an increased interindividual variation. The group with higher HbA1c levels (>6.0%) had no significant population-mean fHR rhythm at 28 or 36 weeks, and no significant fHR-variation rhythm at 36 weeks. Similarly, the group with a lower morning cortisol concentration (≤8.8 µg/dl) had no significant population-mean fHR-variation rhythm at 28 and 36 weeks. These findings indicate that individual fetal rhythmicity is present in pregnancies complicated by PGDM. However, suboptimal maternal glycemic control and a lower maternal morning cortisol concentration are associated with a less-well-synchronized circadian system of the fetus.
Collapse
Affiliation(s)
- Julie Sletten
- a Department of Clinical Science , University of Bergen , Bergen , Norway
| | - Agnethe Lund
- a Department of Clinical Science , University of Bergen , Bergen , Norway.,b Department of Obstetrics and Gynecology , Haukeland University Hospital , Bergen , Norway
| | - Cathrine Ebbing
- b Department of Obstetrics and Gynecology , Haukeland University Hospital , Bergen , Norway
| | - Germaine Cornelissen
- c Department of Integrative Biology and Physiology, Halberg Chronobiology Center , University of Minnesota , Minneapolis , MN , USA
| | - Jörg Aßmus
- d Centre for Clinical Research , Haukeland University Hospital , Bergen , Norway
| | - Torvid Kiserud
- a Department of Clinical Science , University of Bergen , Bergen , Norway.,b Department of Obstetrics and Gynecology , Haukeland University Hospital , Bergen , Norway
| | - Susanne Albrechtsen
- a Department of Clinical Science , University of Bergen , Bergen , Norway.,b Department of Obstetrics and Gynecology , Haukeland University Hospital , Bergen , Norway
| | - Jörg Kessler
- a Department of Clinical Science , University of Bergen , Bergen , Norway.,b Department of Obstetrics and Gynecology , Haukeland University Hospital , Bergen , Norway
| |
Collapse
|
23
|
The Critical Role of the Central Autonomic Nervous System in Fetal-Neonatal Transition. Semin Pediatr Neurol 2018; 28:29-37. [PMID: 30522725 PMCID: PMC6432941 DOI: 10.1016/j.spen.2018.05.004] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The objective of this article is to understand the complex role of the central autonomic nervous system in normal and complicated fetal-neonatal transition and how autonomic nervous system dysfunction can lead to brain injury. The central autonomic nervous system supports coordinated fetal transitional cardiovascular, respiratory, and endocrine responses to provide safe transition of the fetus at delivery. Fetal and maternal medical and environmental exposures can disrupt normal maturation of the autonomic nervous system in utero, cause dysfunction, and complicate fetal-neonatal transition. Brain injury may both be caused by autonomic nervous system failure and contribute directly to autonomic nervous system dysfunction in the fetus and newborn. The central autonomic nervous system has multiple roles in supporting transition of the fetus. Future studies should aim to improve real-time monitoring of fetal autonomic nervous system function and in supporting typical autonomic nervous system development even under complicated conditions.
Collapse
|
24
|
Sletten J, Cornelissen G, Assmus J, Kiserud T, Albrechtsen S, Kessler J. Maternal exercise, season and sex modify the daily fetal heart rate rhythm. Acta Physiol (Oxf) 2018; 224:e13093. [PMID: 29754451 DOI: 10.1111/apha.13093] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 04/18/2018] [Accepted: 05/03/2018] [Indexed: 12/01/2022]
Abstract
AIM The knowledge on biological rhythms is rapidly expanding. We aimed to define the longitudinal development of the daily (24-hour) fetal heart rate rhythm in an unrestricted, out-of-hospital setting and to examine the effects of maternal physical activity, season and fetal sex. METHODS We recruited 48 women with low-risk singleton pregnancies. Using a portable monitor for continuous fetal electrocardiography, fetal heart rate recordings were obtained around gestational weeks 24, 28, 32 and 36. Daily rhythms in fetal heart rate and fetal heart rate variation were detected by cosinor analysis; developmental trends were calculated by population-mean cosinor and multilevel analysis. RESULTS For the fetal heart rate and fetal heart rate variation, a significant daily rhythm was present in 122/123 (99.2%) and 116/121 (95.9%) of the individual recordings respectively. The rhythms were best described by combining cosine waves with periods of 24 and 8 hours. With increasing gestational age, the magnitude of the fetal heart rate rhythm increased, and the peak of the fetal heart rate variation rhythm shifted from a mean of 14:25 (24 weeks) to 20:52 (36 weeks). With advancing gestation, the rhythm-adjusted mean value of the fetal heart rate decreased linearly in females (P < .001) and nonlinearly in males (quadratic function, P = .001). At 32 and 36 weeks, interindividual rhythm diversity was found in male fetuses during higher maternal physical activity and during the summer season. CONCLUSION The dynamic development of the daily fetal heart rate rhythm during the second half of pregnancy is modified by fetal sex, maternal physical activity and season.
Collapse
Affiliation(s)
- J Sletten
- Department of Clinical Science, University of Bergen, Bergen, Norway
| | - G Cornelissen
- Department of Integrative Biology and Physiology, Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN, USA
| | - J Assmus
- Centre for Clinical Research, Haukeland University Hospital, Bergen, Norway
| | - T Kiserud
- Department of Clinical Science, University of Bergen, Bergen, Norway
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway
| | - S Albrechtsen
- Department of Clinical Science, University of Bergen, Bergen, Norway
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway
| | - J Kessler
- Department of Clinical Science, University of Bergen, Bergen, Norway
- Department of Obstetrics and Gynecology, Haukeland University Hospital, Bergen, Norway
| |
Collapse
|
25
|
Non-invasive fetal monitoring using electrocardiography and phonocardiography: A preliminary study. J Gynecol Obstet Hum Reprod 2018; 47:455-459. [PMID: 30144558 DOI: 10.1016/j.jogoh.2018.08.009] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 07/19/2018] [Accepted: 08/20/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND Continuous fetal monitoring is commonly used during pregnancy and labor to assess fetal wellbeing. The most often used technology is cardiotocography (CTG), but this technique has major drawbacks in clinical use. OBJECTIVES Our aim is to test a non-invasive multimodal technique of fetal monitoring using phonocardiography (PCG) and electrocardiography (ECG) and to evaluate its feasibility in clinical practice, by comparison with CTG. METHODS This prospective open label study took place in a French university hospital. PCG and ECG signals were recorded using abdominal and thoracic sensors from antepartum women during the second half of pregnancy, simultaneously with CTG recording. Signals were then processed to extract fetal PCG and ECG and estimate fetal heart rate (FHR). RESULTS A total of 9 sets of recordings were evaluated. Very accurate fetal ECG and fetal PCG signals were recorded, enabling us to obtain FHR for several subjects. The FHR calculated from ECG was highly correlated with the FHR from the CTG reference (from 74% to 84% of correlation). CONCLUSION This work with preliminary signal processing algorithms proves the feasibility of the approach and constitutes the beginnings of a unique database that is needed to improve and validate the signal processing algorithms.
Collapse
|
26
|
Fotiadou E, van Laar JOEH, Oei SG, Vullings R. Enhancement of low-quality fetal electrocardiogram based on time-sequenced adaptive filtering. Med Biol Eng Comput 2018; 56:2313-2323. [PMID: 29938302 PMCID: PMC6245004 DOI: 10.1007/s11517-018-1862-8] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 06/10/2018] [Indexed: 12/05/2022]
Abstract
Extraction of a clean fetal electrocardiogram (ECG) from non-invasive abdominal recordings is one of the biggest challenges in fetal monitoring. An ECG allows for the interpretation of the electrical heart activity beyond the heart rate and heart rate variability. However, the low signal quality of the fetal ECG hinders the morphological analysis of its waveform in clinical practice. The time-sequenced adaptive filter has been proposed for performing optimal time-varying filtering of non-stationary signals having a recurring statistical character. In our study, the time-sequenced adaptive filter is applied to enhance the quality of multichannel fetal ECG after the maternal ECG is removed. To improve the performance of the filter in cases of low signal-to-noise ratio (SNR), we enhance the ECG reference signals by averaging consecutive ECG complexes. The performance of the proposed augmented time-sequenced adaptive filter is evaluated in both synthetic and real data from PhysioNet. This evaluation shows that the suggested algorithm clearly outperforms other ECG enhancement methods, in terms of uncovering the ECG waveform, even in cases with very low SNR. With the presented method, quality of the fetal ECG morphology can be enhanced to the extent that the ECG might be fit for use in clinical diagnostics. The extracted fetal ECG signals from non-invasive abdominal recordings still contain a substantial amount of noise. The time-sequenced adaptive filter provides a relatively accurate estimate of the underlying fetal ECG signal when the quality of the reference channels is enhanced prior to filtering. ![]()
Collapse
Affiliation(s)
- E Fotiadou
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP, Eindhoven, Netherlands.
| | - J O E H van Laar
- Department of Obstetrics and Gynaecology, Máxima Medical Center, 5504 DB, Veldhoven, Netherlands
| | - S G Oei
- Department of Obstetrics and Gynaecology, Máxima Medical Center, 5504 DB, Veldhoven, Netherlands
| | - R Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP, Eindhoven, Netherlands
| |
Collapse
|
27
|
The influence of betamethasone on fetal heart rate variability, obtained by non-invasive fetal electrocardiogram recordings. Early Hum Dev 2018; 119:8-14. [PMID: 29505915 DOI: 10.1016/j.earlhumdev.2018.02.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2017] [Revised: 02/12/2018] [Accepted: 02/13/2018] [Indexed: 11/24/2022]
Abstract
BACKGROUND Betamethasone is widely used to enhance fetal lung maturation in case of threatened preterm labour. Fetal heart rate variability is one of the most important parameters to assess in fetal monitoring, since it is a reliable indicator for fetal distress. AIM To describe the effect of betamethasone on fetal heart rate variability, by applying spectral analysis on non-invasive fetal electrocardiogram recordings. STUDY DESIGN Prospective cohort study. SUBJECTS Patients that require betamethasone, with a gestational age from 24 weeks onwards. OUTCOME MEASURES Fetal heart rate variability parameters on day 1, 2, and 3 after betamethasone administration are compared to a reference measurement. RESULTS Following 68 inclusions, 12 patients remained with complete series of measurements and sufficient data quality. During day 1, an increase in absolute fetal heart rate variability values was seen. During day 2, a decrease in these values was seen. All trends indicate to return to pre-medication values on day 3. Normalised high- and low-frequency power show little changes during the study period. CONCLUSIONS The changes in fetal heart rate variability following betamethasone administration show the same pattern when calculated by spectral analysis of the fetal electrocardiogram, as when calculated by cardiotocography. Since normalised spectral values show little changes, the influence of autonomic modulation seems minor.
Collapse
|
28
|
Warmerdam GJJ, Vullings R, Van Laar JOEH, Van der Hout-Van der Jagt MB, Bergmans JWM, Schmitt L, Oei SG. Detection rate of fetal distress using contraction-dependent fetal heart rate variability analysis. Physiol Meas 2018; 39:025008. [PMID: 29350194 DOI: 10.1088/1361-6579/aaa925] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Monitoring of the fetal condition during labor is currently performed by cardiotocograpy (CTG). Despite the use of CTG in clinical practice, CTG interpretation suffers from a high inter- and intra-observer variability and a low specificity. In addition to CTG, analysis of fetal heart rate variability (HRV) has been shown to provide information on fetal distress. However, fetal HRV can be strongly influenced by uterine contractions, particularly during the second stage of labor. Therefore, the aim of this study is to examine if distinguishing contractions from rest periods can improve the detection rate of HRV features for fetal distress during the second stage of labor. APPROACH We used a dataset of 100 recordings, containing 20 cases of fetuses with adverse outcome. The most informative HRV features were selected by a genetic algorithm and classification performance was evaluated using support vector machines. MAIN RESULTS Classification performance of fetal heart rate segments closest to birth improved from a geometric mean of 70% to 79%. If the classifier was used to indicate fetal distress over time, the geometric mean at 15 minutes before birth improved from 60% to 72%. SIGNIFICANCE Our results show that combining contraction-dependent HRV features with HRV features calculated over the entire fetal heart rate signal improves the detection rate of fetal distress.
Collapse
Affiliation(s)
- G J J Warmerdam
- Faculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands
| | | | | | | | | | | | | |
Collapse
|
29
|
Hoyer D, Żebrowski J, Cysarz D, Gonçalves H, Pytlik A, Amorim-Costa C, Bernardes J, Ayres-de-Campos D, Witte OW, Schleußner E, Stroux L, Redman C, Georgieva A, Payne S, Clifford G, Signorini MG, Magenes G, Andreotti F, Malberg H, Zaunseder S, Lakhno I, Schneider U. Monitoring fetal maturation-objectives, techniques and indices of autonomic function. Physiol Meas 2017; 38:R61-R88. [PMID: 28186000 PMCID: PMC5628752 DOI: 10.1088/1361-6579/aa5fca] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperkinetic, cognitive disorders. Since the autonomic nervous system is involved in all of those systems, cardiac autonomic control may provide relevant functional diagnostic and prognostic information. The fetal heart rate patterns (HRP) are one of the few functional signals in the prenatal period that relate to autonomic control and, therefore, is predestinated for its evaluation. The development of sensitive markers of fetal maturation and its disturbances requires the consideration of physiological fundamentals, recording technology and HRP parameters of autonomic control. Based on the ESGCO2016 special session on monitoring the fetal maturation we herein report the most recent results on: (i) functional fetal autonomic brain age score (fABAS), Recurrence Quantitative Analysis and Binary Symbolic Dynamics of complex HRP resolve specific maturation periods, (ii) magnetocardiography (MCG) based fABAS was validated for cardiotocography (CTG), (iii) 30 min recordings are sufficient for obtaining episodes of high variability, important for intrauterine growth restriction (IUGR) detection in handheld Doppler, (iv) novel parameters from PRSA to identify Intra IUGR fetuses, (v) evaluation of fetal electrocardiographic (ECG) recordings, (vi) correlation between maternal and fetal HRV is disturbed in pre-eclampsia. The reported novel developments significantly extend the possibilities for the established CTG methodology. Novel HRP indices improve the accuracy of assessment due to their more appropriate consideration of complex autonomic processes across the recording technologies (CTG, handheld Doppler, MCG, ECG). The ultimate objective is their dissemination into routine practice and studies of fetal developmental disturbances with implications for programming of adult diseases.
Collapse
Affiliation(s)
- Dirk Hoyer
- Hans Berger Department of Neurology, Biomagnetic Center, Jena University Hospital, Jena 07747, Germany
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Vullings R, Verdurmen KMJ, Hulsenboom ADJ, Scheffer S, de Lau H, Kwee A, Wijn PFF, Amer-Wåhlin I, van Laar JOEH, Oei SG. The electrical heart axis and ST events in fetal monitoring: A post-hoc analysis following a multicentre randomised controlled trial. PLoS One 2017; 12:e0175823. [PMID: 28410419 PMCID: PMC5391944 DOI: 10.1371/journal.pone.0175823] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2016] [Accepted: 03/27/2017] [Indexed: 01/12/2023] Open
Abstract
OBJECTIVE Reducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. However, its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events. METHODS A post-hoc analysis was performed following a multicentre randomised controlled trial, including 1097 patients from two participating centres. All women were monitored with ST analysis during labour. Cases of fetal metabolic acidosis, poor signal quality, missing blood gas analysis, and congenital heart disease were excluded. The orientation of the fetal electrical heart axis affects the height of the initial T/QRS baseline, and therefore the incidence of ST events. We grouped tracings with the same initial baseline T/QRS value. We depicted the number of ST events as a function of the initial baseline T/QRS value with a linear regression model. RESULTS A significant increment of ST events was observed with increasing height of the initial T/QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p<0.001. The most frequent T/QRS baseline is 0.12. CONCLUSION The orientation of the fetal electrical heart axis and accordingly the height of the initial T/QRS baseline should be taken into account in fetal monitoring with ST analysis.
Collapse
Affiliation(s)
- Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
| | - Kim M. J. Verdurmen
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, the Netherlands
| | | | - Stephanie Scheffer
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, the Netherlands
| | - Hinke de Lau
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, the Netherlands
| | - Anneke Kwee
- Department of Obstetrics and Gynaecology, University Medical Centre Utrecht, Utrecht, the Netherlands
| | - Pieter F. F. Wijn
- Department of Clinical Physics, Máxima Medical Centre, Veldhoven, the Netherlands
| | - Isis Amer-Wåhlin
- Department of Women and Child Health, Karolinska Institute, Stockholm, Sweden
| | | | - S. Guid Oei
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, Veldhoven, the Netherlands
| |
Collapse
|
31
|
Jongen GJLM, van der Hout-van der Jagt MB, Oei SG, van de Vosse FN, Bovendeerd PHM. Simulation of fetal heart rate variability with a mathematical model. Med Eng Phys 2017; 42:55-64. [PMID: 28196652 DOI: 10.1016/j.medengphy.2017.01.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Revised: 12/23/2016] [Accepted: 01/17/2017] [Indexed: 11/28/2022]
Abstract
In the clinic, the cardiotocogram (CTG), the combined registration of fetal heart rate (FHR) and uterine contractions, is used to predict fetal well-being. Amongst others, fetal heart rate variability (FHRV) is an important indicator of fetal distress. In this study we add FHRV to our previously developed CTG simulation model, in order to improve its use as a research and educational tool. We implemented three sources of variability by applying either 1/f or white noise to the peripheral vascular resistance, baroreceptor output, or efferent vagal signal. Simulated FHR tracings were evaluated by visual inspection and spectral analysis. All power spectra showed a 1/f character, irrespective of noise type and source. The clinically observed peak near 0.1 Hz was only obtained by applying white noise to the different sources of variability. Similar power spectra were found when peripheral vascular resistance or baroreceptor output was used as source of variability. Sympathetic control predominantly influenced the low frequency power, while vagal control influenced both low and high frequency power. In contrast to clinical data, model results did not show an increase of FHRV during FHR decelerations. Still, addition of FHRV improves the applicability of the model as an educational and research tool.
Collapse
Affiliation(s)
- Germaine J L M Jongen
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands; Department of Gynecology and Obstetrics, Máxima Medical Center, PO Box 7777, 5500 MB Veldhoven, The Netherlands.
| | - M Beatrijs van der Hout-van der Jagt
- Department of Gynecology and Obstetrics, Máxima Medical Center, PO Box 7777, 5500 MB Veldhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands
| | - S Guid Oei
- Department of Gynecology and Obstetrics, Máxima Medical Center, PO Box 7777, 5500 MB Veldhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands
| | - Frans N van de Vosse
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands
| | - Peter H M Bovendeerd
- Department of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB Eindhoven, The Netherlands.
| |
Collapse
|
32
|
Garabedian C, De Jonckheere J, Butruille L, Deruelle P, Storme L, Houfflin-Debarge V. Understanding fetal physiology and second line monitoring during labor. J Gynecol Obstet Hum Reprod 2017; 46:113-117. [PMID: 28403965 DOI: 10.1016/j.jogoh.2016.11.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 11/04/2016] [Accepted: 11/10/2016] [Indexed: 12/31/2022]
Abstract
Cardiotocography (CTG) is a technique used to monitor intrapartum fetal condition and is one of the most common obstetric procedures. Second line methods of fetal monitoring have been developed in an attempt to reduce unnecessary interventions due to continuous cardiotocography and to better identify fetuses at risk of intrapartum asphyxia. The acid-base balance of the fetus is evaluated by fetal blood scalp samples, the modification of the myocardial oxygenation by the fetal ECG ST-segment analysis (STAN) and the autonomic nervous system by the power spectral analysis of the fetal heart variability. To correctly interpret the features observed on CTG traces or second line methods, it seems important to understand normal physiology during labor and the compensatory mechanisms of the fetus in case of hypoxemia. Therefore, the aim of this review is first to describe fetal physiology during labor and then to explain the modification of the second line monitoring during labor.
Collapse
Affiliation(s)
- C Garabedian
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France; Department of obstetrics, Jeanne-de-Flandre hospital, CHU Lille, 59000 Lille, France.
| | - J De Jonckheere
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France; CIC-IT 1403, Maison Régionale de la Recherche Clinique, CHU Lille, 59000 Lille, France
| | - L Butruille
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France
| | - P Deruelle
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France; Department of obstetrics, Jeanne-de-Flandre hospital, CHU Lille, 59000 Lille, France
| | - L Storme
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France; Department of neonatology, Jeanne-de-Flandre hospital, CHU Lille, 59000 Lille, France
| | - V Houfflin-Debarge
- EA 4489, perinatal growth and environment, university Lille, 59000 Lille, France; Department of obstetrics, Jeanne-de-Flandre hospital, CHU Lille, 59000 Lille, France
| |
Collapse
|
33
|
Verdurmen KMJ, Hulsenboom ADJ, van Laar JOEH, Oei SG. Effect of tocolytic drugs on fetal heart rate variability: a systematic review. J Matern Fetal Neonatal Med 2016; 30:2387-2394. [PMID: 27756155 DOI: 10.1080/14767058.2016.1249844] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
INTRODUCTION Tocolytics may cause changes in fetal heart rate (HR) pattern, while fetal heart rate variability (HRV) is an important marker of fetal well-being. We aim to systematically review the literature on how tocolytic drugs affect fetal HRV. MATERIALS AND METHODS We searched CENTRAL, PubMed and EMBASE up to June 2016. Studies published in English, using computerized or visual analysis to describe the effect of tocolytics on HRV in human fetuses were included. Studies describing tocolytics during labor, external cephalic version, pre-eclampsia and infection were excluded. Eventually, we included six studies, describing 169 pregnant women. RESULTS Nifedipine, atosiban and indomethacin administration show no clinically important effect on fetal HRV. Following administration of magnesium sulfate decreased variability and cases of bradycardia are described. Fenoterol administration results in a slight increase in fetal HR with no changes in variability. After ritodrine administration increased fetal HR and decreased variability is seen. The effect of co-administration of corticosteroids should be taken into account. CONCLUSION In order to prevent iatrogenic preterm labor, the effects of tocolytic drugs on fetal HRV should be taken into account when monitoring these fetuses.
Collapse
Affiliation(s)
- Kim M J Verdurmen
- a Department of Obstetrics and Gynecology , Máxima Medical Center , Veldhoven , the Netherlands and
| | - Alexandra D J Hulsenboom
- a Department of Obstetrics and Gynecology , Máxima Medical Center , Veldhoven , the Netherlands and
| | - Judith O E H van Laar
- a Department of Obstetrics and Gynecology , Máxima Medical Center , Veldhoven , the Netherlands and
| | - S Guid Oei
- a Department of Obstetrics and Gynecology , Máxima Medical Center , Veldhoven , the Netherlands and.,b Faculty of Electrical Engineering , Eindhoven University of Technology , Eindhoven , the Netherlands
| |
Collapse
|
34
|
Verdurmen KMJ, Hulsenboom ADJ, van Laar JOEH, Wijn PFF, Vullings R, Oei SG. Orientation of the electrical heart axis in mid-term pregnancy. Eur J Obstet Gynecol Reprod Biol 2016; 207:243-246. [PMID: 27865582 DOI: 10.1016/j.ejogrb.2016.10.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Revised: 10/02/2016] [Accepted: 10/21/2016] [Indexed: 11/25/2022]
Affiliation(s)
- Kim M J Verdurmen
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands.
| | | | - Judith O E H van Laar
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands
| | - Pieter F F Wijn
- Department of Clinical Physics, Máxima Medical Center, Veldhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - S Guid Oei
- Department of Obstetrics and Gynecology, Máxima Medical Center, Veldhoven, The Netherlands; Department of Electrical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
35
|
Verdurmen KMJ, Lempersz C, Vullings R, Schroer C, Delhaas T, van Laar JOEH, Oei SG. Normal ranges for fetal electrocardiogram values for the healthy fetus of 18-24 weeks of gestation: a prospective cohort study. BMC Pregnancy Childbirth 2016; 16:227. [PMID: 27531050 PMCID: PMC4987971 DOI: 10.1186/s12884-016-1021-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2015] [Accepted: 08/08/2016] [Indexed: 01/27/2023] Open
Abstract
Background The fetal anomaly ultrasound only detects 65 to 81 % of the patients with congenital heart disease, making it the most common structural fetal anomaly of which a significant part is missed during prenatal life. Therefore, we need a reliable non-invasive diagnostic method which improves the predictive value for congenital heart diseases early in pregnancy. Fetal electrocardiography could be this desired diagnostic method. There are multiple technical challenges to overcome in the conduction of the fetal electrocardiogram. In addition, interpretation is difficult due to the organisation of the fetal circulation in utero. We want to establish the normal ranges and values of the fetal electrocardiogram parameters in healthy fetuses of 18 to 24 weeks of gestation. Methods/Design Women with an uneventful singleton pregnancy between 18 and 24 weeks of gestation are asked to participate in this prospective cohort study. A certified and experienced sonographist performs the fetal anomaly scan. Subsequently, a fetal electrocardiogram recording is performed using dedicated signal processing methods. Measurements are performed at two institutes. We will include 300 participants to determine the normal values and 95 % confidence intervals of the fetal electrocardiogram parameters in a healthy fetus. We will evaluate the fetal heart rate, segment intervals, normalised amplitude and the fetal heart axis. Three months postpartum, we will evaluate if a newborn is healthy through a questionnaire. Discussion Fetal electrocardiography could be a promising tool in the screening program for congenital heart diseases. The electrocardiogram is a depiction of the intimate relationship between the cardiac nerve conduction pathways and the structural morphology of the fetal heart, and therefore particularly suitable for the detection of secondary effects due to a congenital heart disease (hypotrophy, hypertrophy and conduction interruption).
Collapse
Affiliation(s)
- Kim M J Verdurmen
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. box 7777, 5500 MB, Veldhoven, The Netherlands.
| | - Carlijn Lempersz
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. box 7777, 5500 MB, Veldhoven, The Netherlands
| | - Rik Vullings
- Faculty of Electrical Engineering, Eindhoven University of Technology, P.O. box 513, 5612 AZ, Eindhoven, The Netherlands
| | - Christian Schroer
- Department of Paediatrics, Máxima Medical Centre, P.O. box 7777, 5500 MB, Veldhoven, The Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, P.O. Box 616, 6200 MD, Maastricht, The Netherlands
| | - Judith O E H van Laar
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. box 7777, 5500 MB, Veldhoven, The Netherlands
| | - S Guid Oei
- Department of Obstetrics and Gynaecology, Máxima Medical Centre, P.O. box 7777, 5500 MB, Veldhoven, The Netherlands.,Faculty of Electrical Engineering, Eindhoven University of Technology, P.O. box 513, 5612 AZ, Eindhoven, The Netherlands
| |
Collapse
|
36
|
A systematic review of prenatal screening for congenital heart disease by fetal electrocardiography. Int J Gynaecol Obstet 2016; 135:129-134. [PMID: 27634052 DOI: 10.1016/j.ijgo.2016.05.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 05/21/2016] [Accepted: 07/27/2016] [Indexed: 11/20/2022]
Abstract
BACKGROUND Congenital heart disease (CHD) is the most common severe congenital anomaly worldwide. Diagnosis early in pregnancy is important, but the detection rate by two-dimensional ultrasonography is only 65%-81%. OBJECTIVES To evaluate existing data on CHD and noninvasive abdominal fetal electrocardiography (ECG). SEARCH STRATEGY A systematic review was performed through a search of the Cochrane Library, PubMed, and Embase for studies published up to April 2016 using the terms "congenital heart disease," "fetal electrocardiogram," and other similar keywords. SELECTION CRITERIA Primary articles that described changes in fetal ECG among fetuses with CHD published in English were included. DATA COLLECTION AND ANALYSIS Outcomes of interest were changes in fetal ECG parameters observed for fetuses with congenital heart disease. Findings were reported descriptively. MAIN RESULTS Only five studies described changes observed in the fetal electrocardiogram for fetuses with CHD, including heart rate, heart rate variability, and PR, QRS, and QT intervals. Fetal ECG reflects the intimate relationship between the cardiac nerve conduction system and the structural morphology of the heart. It seems particularly helpful in detecting the electrophysiological effects of cardiac anatomic defects (e.g. hypotrophy, hypertrophy, and conduction interruption). CONCLUSIONS Fetal ECG might be a promising clinical tool to complement ultrasonography in the screening program for CHD.
Collapse
|
37
|
Romano M, Iuppariello L, Ponsiglione AM, Improta G, Bifulco P, Cesarelli M. Frequency and Time Domain Analysis of Foetal Heart Rate Variability with Traditional Indexes: A Critical Survey. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2016; 2016:9585431. [PMID: 27195018 PMCID: PMC4852340 DOI: 10.1155/2016/9585431] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 03/06/2016] [Accepted: 03/07/2016] [Indexed: 11/17/2022]
Abstract
Monitoring of foetal heart rate and its variability (FHRV) covers an important role in assessing health of foetus. Many analysis methods have been used to get quantitative measures of FHRV. FHRV has been studied in time and in frequency domain and interesting clinical results have been obtained. Nevertheless, a standardized definition of FHRV and a precise methodology to be used for its evaluation are lacking. We carried out a literature overview about both frequency domain analysis (FDA) and time domain analysis (TDA). Then, by using simulated FHR signals, we defined the methodology for FDA. Further, employing more than 400 real FHR signals, we analysed some of the most common indexes, Short Term Variability for TDA and power content of the spectrum bands and sympathovagal balance for FDA, and evaluated their ranges of values, which in many cases are a novelty. Finally, we verified the relationship between these indexes and two important parameters: week of gestation, indicator of foetal growth, and foetal state, classified as active or at rest. Our results indicate that, according to literature, it is necessary to standardize the procedure for FHRV evaluation and to consider week of gestation and foetal state before FHR analysis.
Collapse
Affiliation(s)
- Maria Romano
- DMSC, University “Magna Graecia”, Catanzaro, Italy
| | | | | | - Giovanni Improta
- Department of Public Health, University of Naples “Federico II” Hospital, Naples, Italy
| | - Paolo Bifulco
- DIETI, University of Naples “Federico II”, Naples, Italy
| | | |
Collapse
|