Kato H, Iwahana T, Ono R, Okada S, Matsumiya G, Kobayashi Y. Hemodynamic parameters at rest predicting exercise capacity in patients supported with left ventricular assist device. J Artif Organs 2024; 27:7-14. [PMID: 36933087 DOI: 10.1007/s10047-023-01388-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2023] [Accepted: 02/26/2023] [Indexed: 03/19/2023]
Abstract
Left ventricular assist devices improve prognosis and quality of life, but exercise capacity remains limited in most patients after device implantation. Left ventricular assist device optimization through right heart catheterization reduces device-related complications. However, hemodynamic parameters associated with exercise capacity under optimized conditions. The aim of this study was to elucidate the predictors of exercise capacity from hemodynamic parameters at rest after left ventricular assist device optimization. We retrospectively reviewed 24 patients who underwent a ramp test with right heart catheterization, echocardiography and cardiopulmonary exercise testing more than 6 months after left ventricular assist device implantation. Pump speed was optimized to a lower setting that achieved right atrial pressure < 12 mmHg, pulmonary capillary wedge pressure < 18 mmHg, and cardiac index > 2.2 L/min/m2, then exercise capacity was assessed by cardiopulmonary exercise testing. After left ventricular assist device optimization, the mean right atrial pressure, pulmonary capillary wedge pressure, cardiac index, and peak oxygen consumption were 7 ± 5 mmHg, 10 ± 7 mmHg, 2.7 ± 0.5 L/min/m2, and 13.2 ± 3.0 mL/min/kg, respectively. Pulse pressure, stroke volume, right atrial pressure, mean pulmonary artery pressure, and pulmonary capillary wedge pressure were significantly associated with peak oxygen consumption. Multivariate linear regression analysis of factors predicting peak oxygen consumption revealed that pulse pressure, right atrial pressure, and aortic insufficiency remained independent predictors (β = 0.401, p = 0.007; β = - 0.558, p < 0.001; β = - 0.369, p = 0.010, respectively). Our findings suggests that cardiac reserve, volume status, right ventricular function, and aortic insufficiency predict exercise capacity in patients with a left ventricular assist device.
Collapse
Affiliation(s)
- Hirotoshi Kato
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-Ku, Chiba, Chiba, 260-8677, Japan.
| | - Togo Iwahana
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-Ku, Chiba, Chiba, 260-8677, Japan
| | - Ryohei Ono
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Sho Okada
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-Ku, Chiba, Chiba, 260-8677, Japan
| | - Goro Matsumiya
- Department of Cardiovascular Surgery, Chiba University Graduate School of Medicine, Chiba, Japan
| | - Yoshio Kobayashi
- Department of Cardiovascular Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo-Ku, Chiba, Chiba, 260-8677, Japan
| |
Collapse
|
2
|
Chwiedź A, Minarowski Ł, Mróz RM, Razak Hady H. Non-Invasive Cardiac Output Measurement Using Inert Gas Rebreathing Method during Cardiopulmonary Exercise Testing-A Systematic Review. J Clin Med 2023; 12:7154. [PMID: 38002766 PMCID: PMC10671909 DOI: 10.3390/jcm12227154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Revised: 11/02/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023] Open
Abstract
BACKGROUND The use of inert gas rebreathing for the non-invasive cardiac output measurement has produced measurements comparable to those obtained by various other methods. However, there are no guidelines for the inert gas rebreathing method during a cardiopulmonary exercise test (CPET). In addition, there is also a lack of specific standards for assessing the non-invasive measurement of cardiac output during CPET, both for healthy patients and those suffering from diseases and conditions. AIM This systematic review aims to describe the use of IGR for a non-invasive assessment of cardiac output during cardiopulmonary exercise testing and, based on the information extracted, to identify a proposed CPET report that includes an assessment of the cardiac output using the IGR method. METHODS This systematic review was conducted by PRISMA (Preferred Reporting Items for Systematic Reviews and Meta Analyses) guidelines. PubMed, Web of Science, Scopus, and Cochrane Library databases were searched from inception until 29 December 2022. The primary search returned 261 articles, of which 47 studies met the inclusion criteria for this review. RESULTS AND CONCLUSIONS This systematic review provides a comprehensive description of protocols, indications, technical details, and proposed reporting standards for a non-invasive cardiac output assessment using IGR during CPET. It highlights the need for standardized approaches to CPET and identifies gaps in the literature. The review critically analyzes the strengths and limitations of the studies included and offers recommendations for future research by proposing a combined report from CPET-IGR along with its clinical application.
Collapse
Affiliation(s)
- Agnieszka Chwiedź
- I Department of General and Endocrine Surgery, Medical University of Bialystok, 15-276 Bialystok, Poland
- II Department of Lung Diseases and Tuberculosis, Medical University of Bialystok, 15-540 Bialystok, Poland
| | - Łukasz Minarowski
- II Department of Lung Diseases and Tuberculosis, Medical University of Bialystok, 15-540 Bialystok, Poland
| | - Robert M Mróz
- II Department of Lung Diseases and Tuberculosis, Medical University of Bialystok, 15-540 Bialystok, Poland
| | - Hady Razak Hady
- I Department of General and Endocrine Surgery, Medical University of Bialystok, 15-276 Bialystok, Poland
| |
Collapse
|
3
|
[Cardiac rehabilitation in LVAD patients : Aspects regarding exercise and rhythm]. Herzschrittmacherther Elektrophysiol 2023; 34:45-51. [PMID: 36580090 DOI: 10.1007/s00399-022-00914-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 12/05/2022] [Indexed: 12/30/2022]
Abstract
After implantation of a left ventricular assist device (LVAD), it is strongly recommended that patients participate in an inpatient cardiac rehabilitation program (CR). Relevant topics during CR include sports and exercise therapy as well as aspects of cardiac rhythm control. Over time, LVAD patients usually regain a good quality of life and an adequate functional capacity can be observed. However, maximum performance values remain markedly reduced, in part due to the fixed LVAD pump speed and the limited total cardiac output. Therefore, structured long-term exercise training programs (even beyond CR phase II) are of particular importance in order to optimize neuromuscular control and muscle metabolism. Limitations to physical performance values may also be caused by the occurrence of supraventricular and/or ventricular arrhythmias. In both cases, the cause is an increasing hemodynamic impairment of the right heart, which may also lead to a reduced LVAD pump flow. In addition, inadequate setting of other cardiac implantable electronic devices (e.g., implantable cardioverter-defibrillator [ICD] or cardiac resynchronization therapy with defibrillator [CRT-D]) may also have a crucial impact on hemodynamics after LVAD implantation. In this article, we will discuss specific aspects of LVAD therapy related to exercise and rhythm control, particularly in the context of CR programs.
Collapse
|
4
|
Fatrin S, Okwose NC, Bailey K, Velicki L, Popovic D, Ristic A, Seferovic PM, MacGowan GA, Jakovljevic DG. Haemodynamic determinants of quality of life in chronic heart failure. BMC Cardiovasc Disord 2022; 22:412. [PMID: 36114473 PMCID: PMC9479234 DOI: 10.1186/s12872-022-02829-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Accepted: 08/18/2022] [Indexed: 11/23/2022] Open
Abstract
Background Heart failure patients demonstrate reduced functional capacity, hemodynamic function, and quality of life (QOL) which are associated with high mortality and morbidity rate. The aim of the present study was to assess the relationship between functional capacity, hemodynamic response to exercise and QOL in chronic heart failure. Methods A single-centre prospective study recruited 42 chronic heart failure patients (11 females, mean age 60 ± 10 years) with reduced left ventricular ejection fraction (LVEF = 23 ± 7%). All participants completed a maximal graded cardiopulmonary exercise test with non-invasive hemodynamic (bioreactance) monitoring. QOL was assessed using Minnesota Living with Heart Failure Questionnaire. Results The average value of QOL score was 40 ± 23. There was a significant negative relationship between the QOL and peak O2 consumption (r = − 0.50, p ≤ 0.01). No significant relationship between the QOL and selected exercise hemodynamic measures was found, including peak exercise cardiac power output (r = 0.15, p = 0.34), cardiac output (r = 0.22, p = 0.15), and mean arterial blood pressure (r = − 0.08, p = 0.60). Conclusion Peak O2 consumption, but not hemodynamic response to exercise, is a significant determinant of QOL in chronic heart failure patients.
Collapse
|
5
|
Hiraiwa H, Okumura T, Sawamura A, Araki T, Mizutani T, Kazama S, Kimura Y, Shibata N, Oishi H, Kuwayama T, Kondo T, Furusawa K, Morimoto R, Adachi T, Yamada S, Mutsuga M, Usui A, Murohara T. Relationship between spleen size and exercise tolerance in advanced heart failure patients with a left ventricular assist device. BMC Res Notes 2022; 15:40. [PMID: 35144676 PMCID: PMC8832641 DOI: 10.1186/s13104-022-05939-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Accepted: 01/31/2022] [Indexed: 12/28/2022] Open
Abstract
OBJECTIVE Spleen volume increases in patients with advanced heart failure (HF) after left ventricular assist device (LVAD) implantation. However, the relationship between spleen volume and exercise tolerance (peak oxygen consumption [VO2]) in these patients remains unknown. In this exploratory study, we enrolled 27 patients with HF using a LVAD (median age: 46 years). Patients underwent blood testing, echocardiography, right heart catheterization, computed tomography (CT), and cardiopulmonary exercise testing. Spleen size was measured using CT volumetry, and the correlations/causal relationships of factors affecting peak VO2 were identified using structural equation modeling. RESULTS The median spleen volume was 190.0 mL, and peak VO2 was 13.2 mL/kg/min. The factors affecting peak VO2 were peak heart rate (HR; β = 0.402, P = .015), pulmonary capillary wedge pressure (PCWP; β = - 0.698, P = .014), right ventricular stroke work index (β = 0.533, P = .001), blood hemoglobin concentration (β = 0.359, P = .007), and spleen volume (β = 0.215, P = .041). Spleen volume correlated with peak HR, PCWP, and hemoglobin concentration, reflecting sympathetic activity, cardiac preload, and oxygen-carrying capacity, respectively, and was thus related to peak VO2. These results suggest an association between spleen volume and exercise tolerance in advanced HF.
Collapse
Affiliation(s)
- Hiroaki Hiraiwa
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
| | - Takahiro Okumura
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan.
| | - Akinori Sawamura
- Department of Cardiology, Ichinomiya Municipal Hospital, 2-2-22 Bunkyo, Ichinomiya, 491-8558, Japan
| | - Takashi Araki
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Takashi Mizutani
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Shingo Kazama
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Yuki Kimura
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Naoki Shibata
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Hideo Oishi
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Tasuku Kuwayama
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Toru Kondo
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Kenji Furusawa
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Ryota Morimoto
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Takuji Adachi
- Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, 461-8673, Japan
| | - Sumio Yamada
- Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, 461-8673, Japan
| | - Masato Mutsuga
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Akihiko Usui
- Department of Cardiac Surgery, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| | - Toyoaki Murohara
- Department of Cardiology, Nagoya University Graduate School of Medicine, 65 Tsurumai-cho, Showa-ku, Nagoya, 466-8550, Japan
| |
Collapse
|
6
|
OUP accepted manuscript. Eur J Cardiothorac Surg 2022; 62:6526431. [DOI: 10.1093/ejcts/ezac053] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 12/14/2021] [Accepted: 01/25/2022] [Indexed: 11/12/2022] Open
|
7
|
HeartWare HVAD Flow Estimator Accuracy for Left and Right Ventricular Support. ASAIO J 2021; 67:416-422. [PMID: 33769996 DOI: 10.1097/mat.0000000000001247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
Abstract
This study investigated the accuracy of the HeartWare HVAD flow estimator for left ventricular assist device (LVAD) support and biventricular assist device (BiVAD) support for modes of reduced speed (BiVAD-RS) and banded outflow (BiVAD-B). The HVAD flow estimator was evaluated in a mock circulatory loop under changes in systemic and pulmonary vascular resistance, heart rate, central venous pressure, and simulated hematocrit (correlated to viscosity). A difference was found between mean estimated and mean measured flow for LVAD (0.1 ± 0.3 L/min), BiVAD-RS (-0.1 ± 0.2 L/min), and BiVAD-B (0 ± 0.2 L/min). Analysis of the flow waveform pulsatility showed good correlation for LVAD (r2 = 0.98) with a modest spread in error (0.7 ± 0.1 L/min), while BiVAD-RS and BiVAD-B showed similar spread in error (0.7 ± 0.3 and 0.7 ± 0.2 L/min, respectively), with much lower correlation (r2 = 0.85 and r2 = 0.60, respectively). This study demonstrated that the mean flow error of the HVAD flow estimator is similar when the device is used in LVAD, BiVAD-RS, or BiVAD-B configuration. However, the instantaneous flow waveform should be interpreted with caution, particularly in the cases of BiVAD support.
Collapse
|
8
|
Fresiello L, Gross C, Jacobs S. Exercise physiology in left ventricular assist device patients: insights from hemodynamic simulations. Ann Cardiothorac Surg 2021; 10:339-352. [PMID: 34159115 DOI: 10.21037/acs-2020-cfmcs-23] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Left ventricular assist devices (LVADs) assure longer survival to patients, but exercise capacity is limited compared to normal values. Overall, LVAD patients show high wedge pressure and low cardiac output during maximal exercise, a phenomenon hinting at the need for increased LVAD support. Clinical studies investigating the hemodynamic benefits of an LVAD speed increase during exercise, ended in inhomogeneous and sometimes contradictory results. The native ventricle-LVAD interaction changes between rest and exercise, and this evolution is complex, multifactorial and patient-specific. The aim of this paper is to provide a comprehensive overview on the patient-LVAD interaction during exercise and to delineate possible therapeutic strategies for the future. A computational cardiorespiratory model was used to simulate the hemodynamics of peak bicycle exercise in LVAD patients. The simulator included the main cardiovascular and respiratory impairments commonly observed in LVAD patients, so as to represent an average hemodynamic response to exercise. In addition, other exercise responses were simulated, by tuning the chronotropic, inotropic and vascular functions, and implementing aortic regurgitation and stenosis in the simulator. These profiles were tested under different LVAD speeds and LVAD pressure-flow characteristics. Simulations output showed consistency with clinical data from the literature. The simulator allowed the working condition of the assisted ventricle at exercise to be investigated, clarifying the reasons behind the high wedge pressure and poor cardiac output observed in the clinics. Patients with poorer inotropic, chronotropic and vascular functions, are likely to benefit more from an LVAD speed increase during exercise. Similarly, for these patients, a flatter LVAD pressure-flow characteristic can assure better hemodynamic support under physical exertion. Overall, the study evidenced the need for a patient-specific approach on supporting exercise hemodynamics. In this frame, a complex simulator can constitute a valuable tool to define and test personalized speed control algorithms and strategies.
Collapse
Affiliation(s)
- Libera Fresiello
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium.,Institute of Clinical Physiology, National Research Council, Pisa, Italy
| | - Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Steven Jacobs
- Department of Cardiovascular Sciences, Cardiac Surgery, Katholieke Universiteit Leuven, Leuven, Belgium
| |
Collapse
|
9
|
Dridi NP, Vishram-Nielsen JKK, Gustafsson F. Exercise Tolerance in Patients Treated With a Durable Left Ventricular Assist Device: Importance of Myocardial Recovery. J Card Fail 2020; 27:486-493. [PMID: 33347995 DOI: 10.1016/j.cardfail.2020.12.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 11/30/2020] [Accepted: 12/08/2020] [Indexed: 12/27/2022]
Abstract
The number of patients supported with left ventricular assist devices (LVADs) is growing and support times are increasing. This has led to a greater focus on functional capacity of these patients. LVADs greatly improve heart failure symptoms, but surprisingly, improvement in peak oxygen uptake (pVO2) is small and remains decreased at approximately 50% of normal values. Inadequate increase in cardiac output during exercise is the main responsible factor for the low pVO2 in LVAD recipients. Some patients experience LV recovery during mechanical unloading and these patients have a higher pVO2. Here we review the various components determining exercise cardiac output in LVAD recipients and discuss the potential impact of cardiac recovery on these components. LV recovery may affect several components, leading to improved hemodynamics during exercise and, in turn, physical capacity in patients with advanced heart failure undergoing LVAD implantation.
Collapse
Affiliation(s)
- Nadia Paarup Dridi
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | | | - Finn Gustafsson
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
| |
Collapse
|
10
|
Stephens AF, Gregory SD, Burrell AJC, Marasco S, Stub D, Salamonsen RF. Physiological principles of Starling-like control of rotary ventricular assist devices. Expert Rev Med Devices 2020; 17:1169-1182. [PMID: 33094673 DOI: 10.1080/17434440.2020.1841631] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
Introduction: This review explores the Starling-like physiological control method (SLC) for rotary ventricular assist devices (VADs) for severe heart failure. The SLC, based on mathematical models of the circulation, has two functions modeling each ventricle. The first function controls the output of the VAD to the arterial pool according to Starling's law, while the second function accounts for how the blood returns to the heart from the veins. The article aims to expose clinicians to SLC in an accessible and clinically relevant discussion. Areas Covered: The article explores the physiology underlying the controller, its development and how that physiology can be adapted to SLC. Examples of controller performance are demonstrated and discussed using a benchtop model of the cardiovascular system. A discussion of the limitations and criticisms of SLC is presented, followed by a future outlook on the clinical adoption of SLC. Expert Opinion: Due to its simplicity and emulation of the natural cardiac autoregulation, SLC is the superior physiological control method for rotary VADs. However, current technical and regulatory challenges prevent the clinical translation of SLC of VADs. Further technical and regulatory development will enable the clinical translation of SLCs of VADs in the coming years.
Collapse
Affiliation(s)
- Andrew F Stephens
- Department of Mechanical and Aerospace Engineering, Monash University , Melbourne, Australia.,Cardiorespiratory Engineering and Technology Laboratory, Baker Heart and Diabetes Institute , Melbourne, Australia
| | - Shaun D Gregory
- Department of Mechanical and Aerospace Engineering, Monash University , Melbourne, Australia.,Cardiorespiratory Engineering and Technology Laboratory, Baker Heart and Diabetes Institute , Melbourne, Australia
| | | | - Silvana Marasco
- Department of Cardiothoracic Surgery, Alfred Hospital , Melbourne, Australia
| | - Dion Stub
- Cardiorespiratory Engineering and Technology Laboratory, Baker Heart and Diabetes Institute , Melbourne, Australia.,Department of Cardiology, Alfred Hospital , Melbourne, Australia.,Department of Epidemiology and Preventive Medicine, Monash University , Melbourne, Australia
| | - Robert F Salamonsen
- Intensive Care Unit, Alfred Hospital , Melbourne, Australia.,Department of Epidemiology and Preventive Medicine, Monash University , Melbourne, Australia
| |
Collapse
|
11
|
Mirza KK, Gustafsson F. Determinants of Functional Capacity and Quality of Life After Implantation of a Durable Left Ventricular Assist Device. Card Fail Rev 2020; 6:e29. [PMID: 33133643 PMCID: PMC7592460 DOI: 10.15420/cfr.2020.15] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 07/10/2020] [Indexed: 12/13/2022] Open
Abstract
Continuous-flow left ventricular assist devices (LVAD) are increasingly used as destination therapy in patients with end-stage heart failure and, with recent improvements in pump design, adverse event rates are decreasing. Implanted patients experience improved survival, quality of life (QoL) and functional capacity (FC). However, improvement in FC and QoL after implantation is not unequivocal, and this has implications for patient selection and preimplantation discussions with patients and relatives. This article identifies preimplantation predictors of lack of improvement in FC and QoL after continuous-flow LVAD implantation and discusses potential mechanisms, allowing for the identification of potential factors that can be modified. In particular, the pathophysiology behind insufficient improvement in peak oxygen uptake is discussed. Data are included from 40 studies, resulting in analysis of >700 exercise tests. Mean peak oxygen uptake was 13.4 ml/kg/min (equivalent to 48% of predicted value; 259 days after implantation, range 31–1,017 days) and mean 6-minute walk test distance was 370 m (182 days after implantation, range 43–543 days). Finally, the interplay between improvement in FC and QoL is discussed.
Collapse
Affiliation(s)
- Kiran K Mirza
- Department of Cardiology, Rigshospitalet Copenhagen, Denmark
| | - Finn Gustafsson
- Department of Cardiology, Rigshospitalet Copenhagen, Denmark
| |
Collapse
|
12
|
Okwose NC, Bouzas-Cruz N, Fernandez OG, Koshy A, Green T, Woods A, Robinson-Smith N, Tovey S, Mcdiarmid A, Parry G, Schueler S, Macgowan GA, Jakovljevic DG. Validity of Hemodynamic Monitoring Using Inert Gas Rebreathing Method in Patients With Chronic Heart Failure and Those Implanted With a Left Ventricular Assist Device. J Card Fail 2020; 27:414-418. [PMID: 33035686 DOI: 10.1016/j.cardfail.2020.09.479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2020] [Revised: 08/24/2020] [Accepted: 09/29/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE The present study assessed agreement between resting cardiac output estimated by inert gas rebreathing (IGR) and thermodilution methods in patients with heart failure and those implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS Hemodynamic measurements were obtained in 42 patients, 22 with chronic heart failure and 20 with implanted continuous flow LVAD (34 males, aged 50 ± 11 years). Measurements were performed at rest using thermodilution and IGR methods. Cardiac output derived by thermodilution and IGR were not significantly different in LVAD (4.4 ± 0.9 L/min vs 4.7 ± 0.8 L/min, P = .27) or patients with heart failure (4.4 ± 1.4 L/min vs 4.5 ± 1.3 L/min, P = .75). There was a strong relationship between thermodilution and IGR cardiac index (r = 0.81, P = .001) and stroke volume index (r = 0.75, P = .001). Bland-Altman analysis showed acceptable limits of agreement for cardiac index derived by thermodilution and IGR, namely, the mean difference (lower and upper limits of agreement) for patients with heart failure -0.002 L/min/m2 (-0.65 to 0.66 L/min/m2), and -0.14 L/min/m2 (-0.78 to 0.49 L/min/m2) for patients with LVAD. CONCLUSIONS IGR is a valid method for estimating cardiac output and should be used in clinical practice to complement the evaluation and management of chronic heart failure and patients with an LVAD.
Collapse
Affiliation(s)
- Nduka C Okwose
- Cardiovascular Research, Clinical and Translational and Biosciences Research Institutes, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK
| | - Noelia Bouzas-Cruz
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Oscar Gonzalez Fernandez
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Aaron Koshy
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Thomas Green
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Andrew Woods
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Nicola Robinson-Smith
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Sian Tovey
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Adam Mcdiarmid
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Gareth Parry
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Stephan Schueler
- Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Guy A Macgowan
- Cardiovascular Research, Clinical and Translational and Biosciences Research Institutes, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK; Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
| | - Djordje G Jakovljevic
- Cardiovascular Research, Clinical and Translational and Biosciences Research Institutes, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK; Departments of Cardiology and Cardiothoracic Surgery, Freeman Hospital, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK; Cardiovascular Research Division, Faculty of Health and Life Sciences, Coventry University, Coventry, UK.
| |
Collapse
|
13
|
Gustafsson F, Mirza KK, Pya Y, Shaw S, Diegeler A, Netuka I, Lavee J, Garbade J, Morshuis M, Heatley J, Saeed D, Potapov E, Schmitto JD, Zimpfer D. Predictors of Physical Capacity 6 Months After Implantation of a Full Magnetically Levitated Left Ventricular Assist Device: An Analysis From the ELEVATE Registry. J Card Fail 2020; 26:580-587. [PMID: 32417377 DOI: 10.1016/j.cardfail.2020.04.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 03/22/2020] [Accepted: 04/06/2020] [Indexed: 11/15/2022]
Abstract
BACKGROUND In patients with a continuous-flow left ventricular assist device, preimplant predictors of poor physical performance are not well-described. We aimed to identify predictors of inability to walk more than 300 m on 6-minute walk test (6MWT) 6 months after HeartMate 3 implantation. METHODS AND RESULTS Using data from the European Registry of Patients Implanted With a Full Magnetically Levitated LVAD, patients with available 6MWT at 6 months after implantation were included (N = 194) and grouped according to 6MWT distance (6MWD) of >300 m (n = 150) or 6MWD of <300 m (n = 44). Patients walking <300 m were older (60 ± 10 vs 52 ± 12 years; P < .001), more often New York Heart Association functional class IV (63% vs 42%; P = .03), and more often had type 2 diabetes (43% vs 17%; P < .001) at implantation. Atrial fibrillation was seen in 57% in those with a 6MWT of <300 m vs 31% in those walking longer (P < .002). Further, hemoglobin and estimated glomerular filtration rate was lower in those walking <300 m (both P < .01). In multivariable regression analysis, independent predictors of a 6MWD of <300 m were: atrial fibrillation (odds ratio [OR], 3.22; 95% confidence interval [CI], 1.12-8.67), older age (OR for 10-year increment, 2.81; 95% CI, 1.55-5.07), New York Heart Association functional class IV (OR, 3.37; 95% CI, 1.27-8.98), and Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2 (OR, 6.53; 95% CI, 1.92-22.19). CONCLUSIONS Six months after HeartMate 3 implantation, 77% of patients walked >300 meters in 6 minutes. Apart from age and measures of heart failure severity, atrial fibrillation at implantation is an independent predictor of low 6MWD at 6 months after implantation.
Collapse
Affiliation(s)
- Finn Gustafsson
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Denmark.
| | - Kiran K Mirza
- Department of Cardiology, Rigshospitalet, University of Copenhagen, Denmark
| | - Yuri Pya
- National Research Center for Cardiac Surgery, Astana, Kazakhstan
| | - Steven Shaw
- Manchester University NHS Foundation Trust, Southmoor Road, Manchester, UK
| | - Anno Diegeler
- Herzchirurgie, Herz- und Gefäßklinik Bad Neustadt, Bad Neustadt, Germany
| | - Ivan Netuka
- Herzchirurgie, Herz- und Gefäßklinik Bad Neustadt, Bad Neustadt, Germany
| | - Jacob Lavee
- Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Jens Garbade
- Heart Transplantation Unit, Leviev Heart Center, Sheba Medical Center and Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Michiel Morshuis
- University Department for Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany
| | - Jerry Heatley
- Department of Cardiothoracic Surgery, Herz- und Diabeteszentrum NRW, Bad Oeynhausen, Germany
| | | | - Evgenij Potapov
- University Department for Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany; Department of Cardiothoracic and Vascular Surgery, German Heart Center Berlin, Berlin, Germany; DZHK (German Centre for Cardiovascular Research), partner site Berlin, Berlin, Germany
| | - Jan D Schmitto
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Medizinische Hochschule Hannover, Hannover, Germany
| | - Daniel Zimpfer
- Department of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | | |
Collapse
|
14
|
Hemodynamic exercise responses with a continuous-flow left ventricular assist device: Comparison of patients' response and cardiorespiratory simulations. PLoS One 2020; 15:e0229688. [PMID: 32187193 PMCID: PMC7080259 DOI: 10.1371/journal.pone.0229688] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/11/2020] [Indexed: 12/24/2022] Open
Abstract
Background Left ventricular assist devices (LVADs) are an established treatment for end stage heart failure patients. As LVADs do not currently respond to exercise demands, attention is also directed towards improvements in exercise capacity and resulting quality of life. The aim of this study was to explore hemodynamic responses observed during maximal exercise tests to infer underlying patient status and therefore investigate possible diagnostics from LVAD derived data and advance the development of physiologically adaptive LVAD controllers. Methods High resolution continuous LVAD flow waveforms were recorded from 14 LVAD patients and evaluated at rest and during maximum bicycle exercise tests (n = 24). Responses to exercise were analyzed in terms of an increase (↑) or decrease (↓) in minimum (QMIN), mean (QMEAN), maximum flow (QMAX) and flow pulsatility (QP2P). To interpret clinical data, a cardiorespiratory numerical simulator was used that reproduced patients’ hemodynamics at rest and exercise. Different cardiovascular scenarios including chronotropic and inotropic responses, peripheral vasodilation, and aortic valve pathologies were simulated systematically and compared to the patients’ responses. Results Different patients’ responses to exercise were observed. The most common response was a positive change of ΔQMIN↑ and ΔQP2P↑ from rest to exercise (70% of exercise tests). Two responses, which were never reported in patients so far, were distinguished by QMIN↑ and QP2P↓ (observed in 17%) and by QMIN↓ and QP2P↑ (observed in 13%). The simulations indicated that the QP2P↓ can result from a reduced left ventricular contractility and that the QMIN↓ can occur with a better left ventricular contractility and/or aortic insufficiency. Conclusion LVAD flow waveforms determine a patients’ hemodynamic “fingerprint” from rest to exercise. Different waveform responses to exercise, including previously unobserved ones, were reported. The simulations indicated the left ventricular contractility as a major determinant for the different responses, thus improving patient stratification to identify how patient groups would benefit from exercise-responsive LVAD control.
Collapse
|
15
|
Severin R, Sabbahi A, Ozemek C, Phillips S, Arena R. Approaches to improving exercise capacity in patients with left ventricular assist devices: an area requiring further investigation. Expert Rev Med Devices 2019; 16:787-798. [PMID: 31453716 DOI: 10.1080/17434440.2019.1660643] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Introduction: Left ventricular assist device (LVAD) implantation has become a well-established treatment option for patients with end stage heart failure (HF) who are refractory to medical therapy. While LVADs implantation does effectively improve hemodynamic performance many patients still possess peripheral pathological adaptations often present in end-stage HF. Therefore, increased attention has been placed on investigating the effects of exercise training for patients with LVADs to improve clinical outcomes. However, the available evidence on exercise training for patients with LVADs is limited. Areas covered: The purpose of this narrative review is to summarize: 1) The evolution of LVAD technology and usage; 2) The physiological responses to exercise in patients with LVADs; 3) The available evidence regarding exercise training; 4) Potential strategies to implement exercise training programs for this patient population. Expert opinion: The available evidence for exercise training to improve physical function and clinical outcomes for patients with LVADs is promising but limited. Future research is needed to further elucidate the ideal exercise training parameters, method of delivery for exercise training, and unique barriers and facilitators to exercise training for patients receiving LVAD implantation.
Collapse
Affiliation(s)
- Richard Severin
- Department of Physical Therapy, University of Illinois , Chicago , IL , USA
| | - Ahmad Sabbahi
- Department of Physical Therapy, University of Illinois , Chicago , IL , USA
| | - Cemal Ozemek
- Department of Physical Therapy, University of Illinois , Chicago , IL , USA
| | - Shane Phillips
- Department of Physical Therapy, University of Illinois , Chicago , IL , USA
| | - Ross Arena
- Department of Physical Therapy, University of Illinois , Chicago , IL , USA
| |
Collapse
|
16
|
Reiss N, Schmidt T, Langheim E, Bjarnason-Wehrens B, Marx R, Sindermann JR, Knoglinger E. Inpatient Cardiac Rehabilitation of LVAD Patients-Updated Recommendations from the Working Group of the German Society for Prevention and Rehabilitation of Cardiovascular Diseases. Thorac Cardiovasc Surg 2019; 69:70-82. [PMID: 31170737 DOI: 10.1055/s-0039-1691837] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Cardiac rehabilitation physicians are faced to an increasing number of heart failure patients supported by left ventricular assist devices (LVAD). Many of these patients have complex medical issues and prolonged hospitalizations and therefore need special cardiac rehabilitation strategies including psychological, social, and educational support which are actually poorly implemented.Cardiac rehabilitation with clear guidance and more evidence should be considered as an essential component of the patient care plan especially regarding the increasing number of destination patients and their long-term follow-up.In this article the working group for postimplant treatment and rehabilitation of LVAD patients of the German Society for Prevention and Rehabilitation of Cardiovascular Diseases has summarized and updated the recommendations for the cardiac rehabilitation of LVAD patients considering the latest literature.
Collapse
Affiliation(s)
- Nils Reiss
- Schüchtermann-Klinik Bad Rothenfelde, Bad Rothenfelde, Germany
| | - Thomas Schmidt
- Schüchtermann-Klinik Bad Rothenfelde, Bad Rothenfelde, Germany.,Institute of Cardiology and Sports Medicine, German Sports University, Cologne, Germany
| | | | | | - Roger Marx
- MediClin Fachklinik Rhein/Ruhr, Essen, Germany
| | | | | |
Collapse
|
17
|
Malchesky PS. Artificial Organs 2018: A Year in Review. Artif Organs 2019; 43:288-317. [PMID: 30680758 DOI: 10.1111/aor.13428] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Accepted: 01/22/2019] [Indexed: 12/24/2022]
Abstract
In this Editor's Review, articles published in 2018 are organized by category and summarized. We provide a brief reflection of the research and progress in artificial organs intended to advance and better human life while providing insight for continued application of these technologies and methods. Artificial Organs continues in the original mission of its founders "to foster communications in the field of artificial organs on an international level." Artificial Organs continues to publish developments and clinical applications of artificial organ technologies in this broad and expanding field of organ Replacement, Recovery, and Regeneration from all over the world. Peer-reviewed special issues this year included contributions from the 13th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion edited by Dr. Akif Undar, and the 25th Congress of the International Society for Mechanical Circulatory Support edited by Dr. Marvin Slepian. Additionally, many editorials highlighted the worldwide survival differences in hemodialysis and perspectives on mechanical circulatory support and stem cell therapies for cardiac support. We take this time also to express our gratitude to our authors for offering their work to this journal. We offer our very special thanks to our reviewers who give so generously of time and expertise to review, critique, and especially provide meaningful suggestions to the author's work whether eventually accepted or rejected. Without these excellent and dedicated reviewers the quality expected from such a journal could not be possible. We also express our special thanks to our Publisher, John Wiley & Sons for their expert attention and support in the production and marketing of Artificial Organs. We look forward to reporting further advances in the coming years.
Collapse
|
18
|
Schmidt T, Bjarnason-Wehrens B, Mommertz S, Schulte-Eistrup S, Willemsen D, Sindermann J, Predel HG, Reiss N. Development of exercise-related values in heart failure patients supported with a left ventricular assist device. Int J Artif Organs 2018; 42:201-206. [DOI: 10.1177/0391398818815492] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Following implantation of a left ventricular assist device, the build-up and long-term maintenance of adequate exercise capacity and functional performance become crucial. The aim of this study was to observe the development of exercise-related values at different times, as well as to detect possible influencing factors. We performed a prospective single-centre study: 10 patients (63 years, 100% male, body mass index = 27.5, 100% HeartWare) underwent the following diagnostic tests during cardiac rehabilitation and during two subsequent ambulatory visits: 6-min walking test, handgrip strength test, cardiopulmonary exercise test and Minnesota Living with Heart Failure questionnaire. Mean follow-up was 482 days after left ventricular assist device implantation. Significant improvements could be observed between the end of cardiac rehabilitation and ambulatory visit 1; 6-min walking distance increased from 367 to 449 m (p < 0.01), peak VO2 from 10.0 to 11.9 mL/kg/min (p < 0.05) and peak load from 62.4 to 83.0 W (p < 0.01). However, there were no further improvements between ambulatory visit 1 and ambulatory visit 2. In the long term, a significant mean weight gain of more than 10 kg could be observed (p < 0.01). A negative linear correlation between weight gain and absolute improvement in peak load (r = −0.77, p < 0.01) and peak VO2 (r = −0.75, p < 0.05) could be demonstrated. In conclusion, exercise-related values following left ventricular assist device implantation initially improve significantly. Later, however, no further improvements can be observed. In the long term, pronounced weight gain is conspicuous, concomitant with a significantly lower increase in exercise values of the patients. In the future, both dietary and structured physical activity follow-up interventions should be integrated in patient routines.
Collapse
Affiliation(s)
- Thomas Schmidt
- Schüchtermann-Klinik Bad Rothenfelde, Bad Rothenfelde, Germany
- Institute of Cardiology and Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Birna Bjarnason-Wehrens
- Institute of Cardiology and Sports Medicine, German Sport University Cologne, Cologne, Germany
| | | | | | | | | | - Hans-Georg Predel
- Institute of Cardiology and Sports Medicine, German Sport University Cologne, Cologne, Germany
| | - Nils Reiss
- Schüchtermann-Klinik Bad Rothenfelde, Bad Rothenfelde, Germany
| |
Collapse
|
19
|
Gross C, Marko C, Mikl J, Altenberger J, Schlöglhofer T, Schima H, Zimpfer D, Moscato F. LVAD Pump Flow Does Not Adequately Increase With Exercise. Artif Organs 2018; 43:222-228. [PMID: 30155903 PMCID: PMC6589923 DOI: 10.1111/aor.13349] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Revised: 07/27/2018] [Accepted: 08/20/2018] [Indexed: 12/26/2022]
Abstract
Left ventricular assist devices (LVADs) restore cardiovascular circulatory demand at rest with a spontaneous increase in pump flow to exercise. The relevant contribution of cardiac output provided by the LVAD and ejected through the aortic valve for exercises of different intensities has been barely investigated in patients. The hypothesis of this study was that different responses in continuous recorded pump parameters occur for maximal and submaximal intensity exercises and that the pump flow change has an impact on the oxygen uptake at peak exercise (pVO2 ). Cardiac and pump parameters such as LVAD flow rate (QLVAD ), heart rate (HR), and aortic valve (AV) opening were analyzed from continuously recorded LVAD data during physical exercises of maximal (bicycle ergometer test) and submaximal intensities (6-min walk test and regular trainings). During all exercise sessions, the LVAD speed was kept constant. Cardiac and pump parameter responses of 16 patients for maximal and submaximal intensity exercises were similar for QLVAD : +0.89 ± 0.52 versus +0.59 ± 0.38 L/min (P = 0.07) and different for HR: +20.4 ± 15.4 versus +7.7 ± 5.8 bpm (P < 0.0001) and AV-opening with 71% versus 23% of patients (P < 0.0001). Multi-regression analysis with pVO2 (R2 = 0.77) showed relation to workload normalized by bodyweight (P = 0.0002), HR response (P = 0.001), AV-opening (P = 0.02), and age (P = 0.06) whereas the change in QLVAD was irrelevant. Constant speed LVADs provide inadequate support for maximum intensity exercises. AV-opening and improvements in HR show an important role for higher exercise capacities and reflect exercise intensities. Changes in pump flow do not impact pVO2 and are independent of AV-opening and response in HR. An LVAD speed control may lead to adequate left ventricular support during strenuous physical activities.
Collapse
Affiliation(s)
- Christoph Gross
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria
| | - Christiane Marko
- PVA Center for Ambulatory Rehabilitation Vienna, Vienna, Austria
| | - Johann Mikl
- Rehabilitation Center Felbring, Felbring, Austria
| | - Johann Altenberger
- Rehabilitation Center Großgmain, Großgmain, Austria.,Paracelsus Medical University, Salzburg, Austria
| | - Thomas Schlöglhofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria.,Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Heinrich Schima
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria.,Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Daniel Zimpfer
- Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria.,Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ludwig-Boltzmann-Cluster for Cardiovascular Research, Vienna, Austria
| |
Collapse
|
20
|
Chatterjee A, Feldmann C, Dogan G, Hanke JS, Ricklefs M, Deniz E, Haverich A, Schmitto JD. Clinical overview of the HVAD: a centrifugal continuous-flow ventricular assist device with magnetic and hydrodynamic bearings including lateral implantation strategies. J Thorac Dis 2018; 10:S1785-S1789. [PMID: 30034853 DOI: 10.21037/jtd.2018.04.148] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Growing worldwide incidences of end-stage heart failure and declining rates of cardiac transplants have given rise to the need for alternative treatment options, based on mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs). Technologically advanced LVADs such as the HVAD® (HeartWare®, Medtronic) facilitate safe and efficient treatment of heart failure patients with reduced post-operative complications, which is attributed to their considerably miniaturized size. This also facilitates the development and implementation of novel, minimally-invasive surgical techniques. The HVAD is a centrifugal pump, manufactured by HeartWare Inc., (Framingham, MA, USA) and subsequently by Medtronic Inc., (Minnesota, MN, USA), and has been approved for clinical application after receiving the CE Mark approval in 2008 and the FDA approval in 2012. Current research efforts are focused on further miniaturization alongside optimization of electronic and software controllers as well as implementation of the transcutaneous energy transfer (TET) technology. Salient features of the HVAD pump technology, clinical applications and future optimization strategies have been discussed in this article.
Collapse
Affiliation(s)
- Anamika Chatterjee
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Christina Feldmann
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Guenes Dogan
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Jasmin S Hanke
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Marcel Ricklefs
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Ezin Deniz
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Axel Haverich
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| | - Jan D Schmitto
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany
| |
Collapse
|