1
|
Zhang L, Han T, Zhao F, Chen Z, Zhou X, Xu Y. Seven-year refractive outcomes comparing small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis for myopia and myopic astigmatism. Lasers Med Sci 2024; 39:250. [PMID: 39373787 DOI: 10.1007/s10103-024-04200-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 09/23/2024] [Indexed: 10/08/2024]
Abstract
This study aimed to compare the seven-year refractive outcomes of small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of myopia and myopic astigmatism. This retrospective cohort study included 97 eyes of 53 patients who had undergone SMILE or FS-LASIK for myopia seven years prior. Measured parameters included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and manifest refraction. There were no significant differences between the SMILE and FS-LASIK groups in logMAR UDVA, cylinder, and logMAR CDVA at 7 years postoperatively (P>0.05). However, there were significant differences between the two groups in sphere and spherical equivalent (P=0.035 and P=0.016, respectively). UDVA was better than or equal to 20/20 in 81% of the eyes after SMILE and in 63% after FS-LASIK (P = 0.045). The efficacy indices of the SMILE and FS-LASIK groups were 1.04 ± 0.23 and 0.97 ± 0.23 (P=0.405), and the safety indices were 1.18 ± 0.19 and 1.10 ± 0.17 (P=0.543), respectively. This study demonstrates the good predictivity of both SMILE and FS-LASIK. SMILE could offer superior refractive outcomes than FS-LASIK during a 7-year follow-up in correcting myopia and myopic astigmatism.
Collapse
Affiliation(s)
- Luoli Zhang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Tian Han
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Feng Zhao
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
- The Department of Ophthalmology, Shuguang Hospital of Shanghai University of Traditional Chinese Medicine, Shanghai, China
| | - Zhuoyi Chen
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China.
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, No.19 Baoqing Road, Shanghai, China.
| | - Ye Xu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
- Key Laboratory of Myopia and Related Eye Diseases, NHC; Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, China.
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, No.19 Baoqing Road, Shanghai, China.
| |
Collapse
|
2
|
Sedaghat MR, Momeni-Moghaddam H, Yekta AA, Maddah N, Roberts CJ, Savardashtaki M. Early elastic and viscoelastic corneal biomechanical changes after photorefractive keratectomy and small incision lenticule extraction. Int Ophthalmol 2024; 44:302. [PMID: 38954134 DOI: 10.1007/s10792-024-03169-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Accepted: 06/15/2024] [Indexed: 07/04/2024]
Abstract
PURPOSE To compare early changes in the corneal biomechanical parameters after photorefractive keratectomy (PRK) and small incision lenticule extraction (SMILE) and their correlations with corneal shape parameters. METHODS One hundred twenty four eyes received myopic PRK and SMILE for similar amounts of myopia. Corneal tomography with Pentacam HR, biomechanical parameters using Corvis ST, and Ocular Response Analyzer (ORA) were evaluated before and 2 weeks after surgery. The change in each parameter was compared between groups, while the difference in central corneal thickness and cornea-compensated intraocular pressure measured before and after surgery were considered as covariates. RESULTS A significant reduction was seen in the corneal stiffness parameter at first applanation, and an increase in deformation amplitude ratio (DAR), and integrated inverse radius (IIR) in both groups after surgery (p < 0.001) Changes in DAR, and IIR were significantly greater in the SMILE than in the PRK group (p < 0.001) Corneal hysteresis (CH) and corneal resistance factor (CRF) decreased in both SMILE and PRK groups after surgery, (p < 0.001) with no statistically significant difference between groups (p > 0.05) Among new Corvis ST parameters, DAR showed a significant correlation with changes in Ambrosio relational thickness in both groups (p < 0.05). CONCLUSIONS Both techniques caused significant changes in corneal biomechanics in the early postoperative period, with greater elastic changes in the SMILE group compared to the PRK group, likely due to lower tension in the SMILE cap and thinner residual stromal bed in SMILE. There were no differences in viscoelastic changes between them, so the lower CH may reflect the volume of tissue removed.
Collapse
Affiliation(s)
| | - Hamed Momeni-Moghaddam
- Rehabilitation Sciences Research Center, Zahedan University of Medical Sciences, Zahedan, Iran.
| | - Abbas-Ali Yekta
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Nasim Maddah
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Cynthia J Roberts
- Department of Ophthalmology and Visual Sciences; and Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Maryam Savardashtaki
- Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| |
Collapse
|
3
|
Dossari SK. Post-refractive Surgery Dry Eye: A Systematic Review Exploring Pathophysiology, Risk Factors, and Novel Management Strategies. Cureus 2024; 16:e61004. [PMID: 38916023 PMCID: PMC11194137 DOI: 10.7759/cureus.61004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/24/2024] [Indexed: 06/26/2024] Open
Abstract
Dry eye disease frequently manifests following corneal refractive procedures, significantly impacting patients' quality of life. This review systematically synthesizes current evidence on the pathophysiological mechanisms, risk factors, and therapeutic interventions for post-refractive surgery dry eye. Following the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines, a systematic review of literature published until August 2023 was conducted, focusing on post-refractive surgery dry eye. Eighteen relevant studies were identified through screening and eligibility assessment. A qualitative synthesis of outcomes was performed using narrative and thematic analysis methods. Surgically induced neurotrophic deficiency, stemming from nerve transection, triggers a cascade of events including apoptosis, inflammation, and lacrimal dysfunction, ultimately leading to tear film instability. Risk factors such as female gender, thyroid eye disease, meibomian gland dysfunction, higher ablation depths, and the use of LASIK over surface ablation exacerbate the condition. While conventional treatments like artificial tears provide temporary relief, emerging interventions such as nerve growth factors, matrix metalloproteinase inhibitors, serum eye drops, and specialized contact lenses show promise in promoting nerve regeneration and epithelial healing. Strategies such as customized ablation profiles, smaller optical zones, and nerve-sparing techniques like small incision lenticule extraction demonstrate potential advantages. A multifaceted therapeutic approach targeting neuroprotection, anti-inflammatory mechanisms, and tear film stabilization is imperative for effectively managing post-refractive surgery dry eye. Future research should focus on evaluating prognostic biomarkers, exploring precision medicine approaches, and investigating neuroprotective adjuvants to further enhance treatment outcomes.
Collapse
Affiliation(s)
- Saif K Dossari
- Department of Surgery, King Faisal University, Al-Hofuf, SAU
| |
Collapse
|
4
|
Zarei-Ghanavati S, Jafarzadeh SV, Es'haghi A, Kiarudi MY, Hassanzadeh S, Ziaei M. Comparison of 110- and 145-µm Small-Incision Lenticule Extraction Cap Thickness: A Randomized Contralateral Eye Study. Cornea 2024; 43:154-158. [PMID: 37186807 DOI: 10.1097/ico.0000000000003294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Accepted: 03/13/2023] [Indexed: 05/17/2023]
Abstract
PURPOSE To investigate the visual, refractive, and biomechanical outcomes of small incision lenticule extraction (SMILE) with two different cap thicknesses. METHODS Thirty-four patients were included in this prospective, randomized, contralateral eye study. Subjects were randomized to receive SMILE surgery with a 110-m cap thickness in one eye and 145-µm cap thickness in the fellow eye. Uncorrected and corrected distance visual acuity, contrast sensitivity (CS), total higherorder aberrations (THOAs) and corneal biomechanical properties were compared 3 months after surgery. RESULTS Postoperative refractive and visual outcomes, CS and THOAs were similar between the two groups ( P > 0.05 for all parameters). At 3 months postoperatively, there was a significant difference in Corvis ST Biomechanical Index (CBI); stiffness parameter at first applanation (SP A1), and Integrated Radius between the two groups (all P < 0.05). CONCLUSIONS Eyes with thicker SMILE corneal caps showed no advantage regarding visual acuity, CS and THOAs over eyes with thinner caps. However, higher cap thickness may result in better corneal biomechanical properties postoperatively.
Collapse
Affiliation(s)
| | | | - Acieh Es'haghi
- Eye Research Center, Five Senses Health Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran
| | | | - Samira Hassanzadeh
- Refractive Error Research Center, Paramedical College, Mashhad University of Medical Sciences, Mashhad, Iran; and
| | - Mohammed Ziaei
- Department of Ophthalmology, New Zealand National Eye Centre, Faculty of Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
5
|
Zhang H, Asroui L, Tarib I, Dupps WJ, Scarcelli G, Randleman JB. Motion-Tracking Brillouin Microscopy Evaluation of Normal, Keratoconic, and Post-Laser Vision Correction Corneas. Am J Ophthalmol 2023; 254:128-140. [PMID: 36963605 PMCID: PMC11108093 DOI: 10.1016/j.ajo.2023.03.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 03/06/2023] [Accepted: 03/11/2023] [Indexed: 03/26/2023]
Abstract
PURPOSE To characterize focal biomechanical differences between normal, keratoconic, and post-laser vision correction (LVC) corneas using motion-tracking Brillouin microscopy. DESIGN Prospective cross-sectional study. METHODS Thirty eyes from 30 patients (10 normal controls [Controls], 10 post-LVC, and 10 stage I or II keratoconus [KC]) had Scheimpflug and motion-tracking Brillouin microscopy imaging using a custom-built device. Mean, maximum (max) and minimum (min) Brillouin shift, spatial standard deviation, and max-min values were compared. Min values were correlated with local Brillouin values at multiple Scheimpflug imaging locations. RESULTS Mean (P < .0003), min (P < .00001), spatial standard deviation (P < .01), and max-min (P < .001) were significantly different between the groups. In post hoc pairwise comparisons, the best differentiators for group comparisons were mean (P = .0004) and min (P = .000002) for Controls vs KC, min (P = .0022) and max-min (P = .002) for Controls vs LVC, and mean (P = .0037) and min (P = .0043) for LVC vs KC. Min (area under the receiver operating characteristic = 1.0) and mean (area under the receiver operating characteristic = 0.96) performed well in differentiating Control and KC eyes. Min values correlated best with Brillouin shift values at the thinnest corneal point (r2 = 0.871, P = .001) and maximum keratometry value identified in the tangential curvature map (r2 = 0.840, P = .002). CONCLUSIONS Motion-tracking Brillouin microscopy effectively characterized focal corneal biomechanical alterations in LVC and KC and clearly differentiated these groups from Controls. Primary motion-tracking Brillouin metrics performed well in differentiating groups as compared with basic Scheimpflug metrics, in contrast to previous Brillouin studies, and identified focal changes after LVC where prior Brillouin studies did not.
Collapse
Affiliation(s)
- Hongyuan Zhang
- From The Cole Eye Institute, Cleveland Clinic (H.Z., L.A., I.T., W.J.D., J.B.R.)
| | - Lara Asroui
- From The Cole Eye Institute, Cleveland Clinic (H.Z., L.A., I.T., W.J.D., J.B.R.)
| | - Imane Tarib
- From The Cole Eye Institute, Cleveland Clinic (H.Z., L.A., I.T., W.J.D., J.B.R.)
| | - William J Dupps
- From The Cole Eye Institute, Cleveland Clinic (H.Z., L.A., I.T., W.J.D., J.B.R.); Cleveland Clinic Lerner College of Medicine of Case Western Reserve University (W.J.D., J.B.R.); Department of Biomedical Engineering, Case Western Reserve University (W.J.D.), Cleveland, Ohio
| | - Giuliano Scarcelli
- Fischell Department of Bioengineering, University of Maryland, College Park, Maryland (GS), USA
| | - J Bradley Randleman
- From The Cole Eye Institute, Cleveland Clinic (H.Z., L.A., I.T., W.J.D., J.B.R.); Cleveland Clinic Lerner College of Medicine of Case Western Reserve University (W.J.D., J.B.R.).
| |
Collapse
|
6
|
Chen S, Ma H, Zhao C. Corneal biomechanics after small incision lenticule extraction and femtosecond laser in situ keratomileusis: A systematic review and meta-analysis. Medicine (Baltimore) 2023; 102:e34580. [PMID: 37565903 PMCID: PMC10419641 DOI: 10.1097/md.0000000000034580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Accepted: 07/13/2023] [Indexed: 08/12/2023] Open
Abstract
BACKGROUND Small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) have been extensively studied as the main surgical methods for corneal refractive surgery. However, there is no consensus on whether SMILE is superior to FS-LASIK in corneal biomechanics. Therefore, this systematic review and meta-analysis used the results of ocular response analyzer and corvis ST to explore whether SMILE is superior to FS-LASIK in corneal biomechanics. METHODS The literature was searched in PubMed, EMBASE, and Controlled Trials Register databases. The Cochrane Collaboration's "risk of bias" tool was used to evaluate the quality of the included randomized clinical trials, and the Newcastle-Ottawa Scale was used to evaluate the included non-randomized controlled trials. The results were analyzed using Revman 5.3. RESULTS Sixteen studies (3 randomized clinical trials and 13 non-randomized controlled trials) were included in this meta-analysis. There was no statistical difference in corneal biomechanics between SMILE and FS-LASIK in corneal hysteresis [mean difference (MD), 0.20; 95% confidence interval (CI): -0.09, 0.49; P = .18] and corneal resistant factor (MD, 0.31; 95% CI: -0.09, 0.71; P = .13), A1 time (MD, -0.02; 95% CI: -0.11, 0.07; P = .66), A1 length (MD, 0.01; 95% CI: -0.01, 0.03; P = .42), A1 velocity (MD, 0.00; 95% CI: -0.01, 0.01; P = .85), A2 velocity (MD, -0.01; 95% CI: -0.11, 0.09; P = .86), HC time (MD, 0.12; 95% CI: -0.13, 0.38; P = .35), The stiffness parameter at first applanation (MD, -7.91; 95% CI: -17.96, 2.14; P = .12), The ratio between the deformation amplitude 2 mm away from apex and the apical deformation (MD, 0.01; 95% CI: -0.26, 0.27; P = .96). CONCLUSION A comprehensive assessment of the parameters of ocular response analyzer and corvis ST showed that SMILE is not superior to LASIK in corneal biomechanics 3 months post-surgery.
Collapse
Affiliation(s)
- Songbai Chen
- Aier Huangpi Eye Hospital, Wuhan, Hubei Province, China
| | - Hongjie Ma
- Zhengzhou Aier Eye Hospital, Zhengzhou, Henan Province, China
| | - Congling Zhao
- Aier Huangpi Eye Hospital, Wuhan, Hubei Province, China
| |
Collapse
|
7
|
Ladi JS, Gaikwad A, Shah NA. Comparative study of small incision refractive lenticule extraction with 5 mm versus 6.5 mm optic zone for myopia. Indian J Ophthalmol 2023; 71:2717-2721. [PMID: 37417110 PMCID: PMC10491035 DOI: 10.4103/ijo.ijo_2559_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/31/2023] [Accepted: 04/05/2023] [Indexed: 07/08/2023] Open
Abstract
Purpose To compare residual stromal thickness (RST) in eyes undergoing small incision refractive lenticule extraction (SMILE) using a lenticular diameter of 6.5 mm versus those with a diameter of 5 mm. Methods: In this retrospective comparative case series. , consecutive patients who underwent SMILE between 2016 and 2021 with at least 6 months of follow-up were included. Preoperative best-corrected distance visual acuity (BCDVA), refractive error, contrast sensitivity, central corneal thickness, keratometry, higher order aberrations, and scotopic pupil size were recorded using a Placido disk topography with Sheimpflug tomography-based system. Patients underwent SMILE with a lenticular diameter of 6.5 mm until 2018 (n = 372 eyes). Thereafter, the lenticular diameter was reduced to 5 mm (n = 318). The RST, postoperative refraction, aberrations, subjective glare, and halos were compared across groups at 1 and 6 months. Results The mean age of participants was 26.8 ± 5.8 years with a mean preoperative spherical equivalent of -4.48 D ± 2.16 D (range: -0.75 to -12.25 D) and mean scotopic pupil of 3.7 ± 0.75 mm. Eyes in the 5 mm group had 30.6 m (95% confidence interval [CI] = 28 to 33 m, P < 0.001) greater RST compared to the 6.5 mm group after adjusting for spherical equivalent and preoperative pachymetry. There were no differences in vision, contrast sensitivity, aberrations (wavefront error of 0.19 ± 0.2 vs. 0.25 ± 0.2, P = 0.19) or glare between the two groups. Conclusion SMILE performed with a lenticular diameter of 5 mm leads to greater RST across the myopic range, but without inducing significant higher-order aberrations.
Collapse
Affiliation(s)
- Jeevan S Ladi
- Department of Ophthalmology, Dada Laser Eye Institute, Pune, Maharashtra, India
| | - Anita Gaikwad
- Department of Ophthalmology, Dada Laser Eye Institute, Pune, Maharashtra, India
| | - Nitant A Shah
- Department of Ophthalmology, Dada Laser Eye Institute, Pune, Maharashtra, India
| |
Collapse
|
8
|
Zheng Y, Xue C, Wang J, Chen X, Wang X, Wang Y. Analysis of the correlation between biomechanical properties and corneal densitometry in myopic eyes. Front Bioeng Biotechnol 2023; 11:1182372. [PMID: 37180047 PMCID: PMC10169733 DOI: 10.3389/fbioe.2023.1182372] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 04/04/2023] [Indexed: 05/15/2023] Open
Abstract
Background: To investigate the correlation between corneal biomechanical characteristics (in vitro and in vivo) and corneal densitometry in myopia. Methods: The Pentacam (Oculus, Wetzlar, Germany) corneal densitometry (CD) and Corvis ST (Oculus, Wetzlar, Germany) exams were conducted prior to surgery for myopic patients who were intended to undergo small-incision lenticule extraction (SMILE). CD values (grayscale units, GSUs), and in vivo biomechanical parameters were obtained. The stromal lenticule was subjected to a uniaxial tensile test to obtain the elastic modulus E in vitro. We exam the correlations among in vivo, in vitro biomechanical characteristics and CD values. Results: In this study, 37 myopic patients (63 eyes) were included. The mean age of participants was 25.14 ± 6.74 years (range:16-39 years). The mean CD values of the total cornea, anterior layer, intermediate layer, posterior layer, 0-2 mm region and 2-6 mm region were 15.03 ± 1.23 GSU, 20.35 ± 1.98 GSU, 11.76 ± 1.01 GSU, 10.95 ± 0.83 GSU, 15.57 ± 1.12 GSU and 11.94 ± 1.77 GSU, respectively. Elastic modulus E (in vitro biomechanical indicator) was negatively correlated with intermediate layer CD (r = -0.35, p = 0.01) and 2-6 mm region CD (r = -0.39, p = 0.00). A negative correlation was also found between 0-2 mm central region CD and in vivo biomechanical indicator SP-HC (r = -0.29, p = 0.02). Conclusion: In myopic patients, densitometry is negatively correlated with biomechanical properties both in vivo and in vitro. With an increase in CD, the cornea deformed more easily.
Collapse
Affiliation(s)
- Yuwei Zheng
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
- The Second Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Chao Xue
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
| | - Jing Wang
- The Second Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Xuan Chen
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
| | - Xiaohui Wang
- The Second Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
- Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China
| |
Collapse
|
9
|
Li N, Chen T, Tian G, Lin Y, Meng Y, Gao H, Liu M. Changes in aberrations and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) in eyes with high astigmatism: a retrospective case control study. BMC Ophthalmol 2023; 23:62. [PMID: 36782180 PMCID: PMC9923895 DOI: 10.1186/s12886-023-02809-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Accepted: 02/06/2023] [Indexed: 02/15/2023] Open
Abstract
BACKGROUND To compare the 6-month changes in aberration and biomechanics after femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for high astigmatism. METHODS In this retrospective case control study, 47 eyes with high astigmatism (≥ 2.5 D, HA group) and 47 eyes with low astigmatism (≤ 1.0 D, LA group) underwent FS-LASIK. Preoperative and follow-up examinations included visual outcomes, higher order aberrations (HOAs) and biomechanics. Biomechanical parameters include a deformation amplitude ratio of 2 mm (DA ratio 2 mm), integrated inverse radius (IIR), stiffness parameter at first applanation (SP-A1), and ambrosio relational thickness through the horizontal meridian (ARTh). RESULTS Six months postoperatively, there was no significant difference in the efficacy and safety index (both P > 0.05) between the two groups, but the cylinder was higher in the HA group. The HOAs increased significantly after surgery in both groups (all P < 0.05). Six months postoperatively, the changes in spherical aberration and HOAs were larger in the HA group (both P < 0.005), but there was no significant difference between the changes in coma (P > 0.05). Significant decreases in SP-A1 and ARTh and significant increases in the IIR and DA ratio of 2 mm (all P < 0.05) were observed after surgery in both groups. The changes in the DA ratio 2 mm, IIR, SP-A1, and ARTh were not significantly different between the groups. CONCLUSION FS-LASIK had relative comparable efficacy and safety in correcting high and low myopic astigmatism, with higher astigmatic under-correction in eyes with high astigmatism. High astigmatism in eyes after FS-LASIK could introduce larger corneal aberrations, but the impact on corneal stiffness was the same as that in eyes with low astigmatism.
Collapse
Affiliation(s)
- Na Li
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Tong Chen
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Ge Tian
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Yue Lin
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Yuan Meng
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Hua Gao
- grid.490473.dEye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021 Jinan, China ,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021 Jinan, China ,grid.410638.80000 0000 8910 6733School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021 Jinan, China
| | - Mingna Liu
- Eye Institute of Shandong First Medical University, Eye Hospital of Shandong First Medical University (Shandong Eye Hospital), 372 Jingsi Road, 250021, Jinan, China. .,State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, 372 Jingsi Road, 250021, Jinan, China. .,School of Ophthalmology, Shandong First Medical University, 372 Jingsi Road, 250021, Jinan, China.
| |
Collapse
|
10
|
Bao F, Lopes BT, Zheng X, Ji Y, Wang J, Elsheikh A. Corneal Biomechanics Losses Caused by Refractive Surgery. Curr Eye Res 2023; 48:137-143. [PMID: 36001080 DOI: 10.1080/02713683.2022.2103569] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Recent advances, specifically in the understanding of the biomechanical properties of the cornea and its response to diseases and surgical interventions, have significantly improved the safety and surgical outcomes of corneal refractive surgery, whose popularity and demand continue to grow worldwide. However, iatrogenic keratectasia resulting from the deterioration in corneal biomechanics caused by surgical interventions, although rare, remains a global concern. On one hand, in vivo biomechanical evaluation, enabled by clinical imaging systems such as the ORA and the Corvis ST, has significantly improved the risk profiling of patients for iatrogenic keratectasia. That is despite the fact the biomechanical metrics provided by these systems are considered indicators of the cornea's overall stiffness rather than its intrinsic material properties. On the other hand, new surgical modalities including SMILE were introduced to offer superior biomechanical performance to LASIK, but this superiority could not be proven clinically, creating more myths than answers. The literature also includes sound evidence that tPRK provided the highest preservation of corneal biomechanics when compared to both LASIK and SMILE. The aim of this review is twofold; to discuss the importance of corneal biomechanical evaluation prior to refractive surgery, and to assess the current understanding of cornea's biomechanical deterioration caused by mainstream corneal refractive surgeries. The review has led to an observation that new imaging techniques, parameters and evaluation systems may be needed to reflect the true advantages of specific refractive techniques and when these advantages are significant enough to offer better protection against post-surgery complications.
Collapse
Affiliation(s)
- FangJun Bao
- Eye Hospital, Wenzhou Medical University, Wenzhou, China.,The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Bernardo T Lopes
- School of Engineering, University of Liverpool, Liverpool, UK.,Department of Ophthalmology, Federal University of Sao Paulo (UNIFESP), Sao Paulo, Brazil
| | - XiaoBo Zheng
- Eye Hospital, Wenzhou Medical University, Wenzhou, China.,The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - YuXin Ji
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - JunJie Wang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China.,The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, UK.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China.,National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
11
|
Liu M, Jin C, Lu L, Yuan Y, Chen C, Zhao T, Ke B. The Impact of Corneal Epithelial Thickening and Inhomogeneity on Corneal Aberrations After Small Incision Lenticule Extraction. J Refract Surg 2023; 39:23-32. [PMID: 36630428 DOI: 10.3928/1081597x-20221109-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
PURPOSE To investigate the corneal epithelial remodeling profile after small incision lenticule extraction (SMILE), the correlated explanatory variables, and its potential impact on corneal higher order aberrations (HOAs). METHODS This single-center study prospectively evaluated 75 right eyes of 75 patients scheduled for SMILE. An anterior segment optical coherence tomography device was used to automatically obtain central 6-mm corneal epithelial thickness (ET), total corneal HOAs, and individual Zernike components before and after surgery. The ET inhomogeneity over the central 3- and 6-mm cornea was quantified with coefficient of variance (CV). RESULTS Both ET and CV significantly increased 1 month postoperatively (all P < .05). The stepwise multiple regression analysis showed that ET and CV were significantly correlated with preoperative ET and CV, respectively (all P < .01). The corrected spherical equivalent also significantly influenced ET and CV (all P < .01). Over the central 6-mm zone, the alterations of total corneal HOAs and individual Zernike components such as vertical coma (Z7) and spherical aberration (Z12, Z24) were significantly correlated with ET and CV (all P < .05). CONCLUSIONS The SMILE-induced epithelial remodeling involved both ET and ET inhomogeneity. The modulation was associated with preoperative and treatment parameters, and exerted a significant impact on corneal HOA alterations especially over the central 6-mm cornea. Together with the amount of correction and corneal curvature gradient change, preoperative assessment of ET and ET inhomogeneity might help predict postoperative epithelial remodeling. [J Refract Surg. 2023;39(1):23-32.].
Collapse
|
12
|
Gao W, Zhao X, Wang Y. Change in the corneal material mechanical property for small incision lenticule extraction surgery. Front Bioeng Biotechnol 2023; 11:1034961. [PMID: 36890912 PMCID: PMC9986312 DOI: 10.3389/fbioe.2023.1034961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Accepted: 02/10/2023] [Indexed: 02/22/2023] Open
Abstract
Purpose: To assess the distribution characteristics and related factors of stress-strain index (SSI) values and discuss changes in biomechanical parameters, including SSI, after small incision lenticule extraction (SMILE) surgery. Methods: This study included 253 patients who underwent SMILE (253 eyes). SSI and other biomechanical parameters were measured using corneal visualization Scheimpflug technology before and 3 months after surgery. The data collected included SSI, central corneal thickness (CCT), and eight other dynamic corneal response parameters. The Kolmogorov-Smirnov test, Pearson and partial correlation analyses, and paired-sample t-tests were used for statistical analyses. Results: Both pre-op SSI and ΔSSI follow a normal distribution, while post-op SSI does not follow a normal distribution. The decline in SSI after SMILE surgery was not statistically significant, and the data dispersion of SSI after SMILE surgery was close to that before surgery (p > 0.05). No statistical correlation was noted between SSI values and age and pre-op CCT (all p > 0.05). However, both pre- and post-op SSI values decreased with increasing degree of myopia (all p < 0.05), and weakly correlated with preoperative intraocular pressure and biomechanically corrected intraocular pressure (all p < 0.05). Other biomechanical parameters changed significantly after surgery (all p < 0.001). After SMILE, the magnitude of the deformation at the highest concave, deformation ratio, and integral radius increased significantly (all p < 0.001), while the Ambrosio relational thickness horizontal, stiffness parameter A1, and Corvis biomechanical index decreased significantly (p < 0.001). Conclusion: SSI, which reflects essential corneal material attributes, differs from other corneal biomechanical parameters and remains stable before and after SMILE surgery, and can be used as an indicator to evaluate changes in corneal material properties after SMILE surgery.
Collapse
Affiliation(s)
- Wenjing Gao
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China.,Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China
| | - Xinheng Zhao
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China.,Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China
| | - Yan Wang
- Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.,Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Tianjin Eye Hospital, Tianjin, China.,Nankai University Eye Institute, Nankai University Affiliated Eye Hospital, Nankai University, Tianjin, China
| |
Collapse
|
13
|
Clinical Evaluation of Corneal Biomechanics following Laser Refractive Surgery in Myopic Eyes: A Review of the Literature. J Clin Med 2022; 12:jcm12010243. [PMID: 36615041 PMCID: PMC9821300 DOI: 10.3390/jcm12010243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/18/2022] [Accepted: 12/23/2022] [Indexed: 12/31/2022] Open
Abstract
The role of corneal biomechanics in laser vision correction (LVC) is currently being raised in the assessment of postoperative corneal ectasia risk. The aim of the paper was to evaluate the changes in corneal biomechanics after LVC procedures based on a systematic review of current studies. The results of a search of the literature in the PubMed, Science Direct, Google Scholar, and Web of Science databases were selected for final consideration according to the PRISMA 2020 flow diagram. Included in our review were 17 prospective clinical studies, with at least 6 months of follow-up time. Corneal biomechanical properties were assessed by Ocular Response Analyzer (ORA), or Corvis ST. The results of the study revealed the highest corneal biomechanics reduction after laser in situ keratomileusis (LASIK) followed by small incision lenticule extraction (SMILE) and surface procedures, such as photorefractive keratectomy (PRK) or laser-assisted sub-epithelial keratectomy (LASEK). In SMILE procedure treatment planning, the use of thicker caps preserves the corneal biomechanics. Similarly, reduction of flap thickness in LASIK surgery maintains the corneal biomechanical strength. Future prospective clinical trials with standardization of the study groups and surgical parameters are needed to confirm the results of the current review.
Collapse
|
14
|
Peñarrocha‐Oltra S, Soto‐Peñaloza R, Alonso‐Arroyo A, Vidal‐Infer A, Pascual‐Segarra J. Laser-based refractive surgery techniques to treat myopia in adults. An overview of systematic reviews and meta-analyses. Acta Ophthalmol 2022; 100:878-893. [PMID: 35535010 PMCID: PMC9790262 DOI: 10.1111/aos.15160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 03/22/2022] [Accepted: 04/18/2022] [Indexed: 12/30/2022]
Abstract
Systematic reviews (SRs) and meta-analyses (MAs) are of great importance for basing clinical decisions. However, misleading interpretations may result when informed decisions rest on biased review papers with methodological issues. To evaluate which treatment is optimal, an overview was made of SRs and MAs to establish the quality and certainty of meta-evidence published on the efficacy of laser-based refractive surgery techniques for treating myopia in adults. A search was made in five databases and was updated using Really Simple Syndication (RSS) feed appliances up to April 2021; SRs with or without MAs were included. Methodological quality was appraised using the AMSTAR-2 tool. The best available reviews were summarized using the GRADE approach. The corrected covered area (CCA) was used to determine the degree of over-representation of publications. The risk of bias of the primary studies was disclosed visually. Thirty-six studies published between 2003 and 2021 were included. Twenty SRs (56%) were conducted in China. The most studied comparisons were SMILE versus FS-LASIK (19%) and FS-LASIK versus MM-LASIK (11%). Of the 251 overlapping index publications, 165 were unique (CCA = 0.015%), representing a negligible risk of skewed reporting. The AMSTAR-2 tool showed most SRs to have critically low or low quality. Nine reviews presented moderate quality. The GRADE approach of the 41 a priori outcomes evidenced critically low and low certainty of evidence. Only the spherical equivalent refraction changes at 12 months between LASEK and PRK showed moderate certainty of evidence, favouring PRK (mean difference 0.06, 95%CI [-0.02 to 0.14], I2 = 0%; p ≥ 0.05). Index trials among less biased reviews are prone to selection, performance and reporting bias. The appraised techniques exhibit comparable results in terms of efficacy. There is moderate certainty of evidence in favour of the use of PRK over LASEK in terms of the spherical equivalent refraction error changes at 1 year of follow-up. Most appraised SRs presented methodological flaws in critical domains, resulting in a low to critically low certainty of evidence after GRADE appraisal. Therefore, investigators need to study and compare the different laser-based refractive techniques to provide better evidence-based medicine. Further well-designed, high-quality clinical trials and SRs are needed to reappraise the current findings.
Collapse
Affiliation(s)
- Sonia Peñarrocha‐Oltra
- Hospital Lluís AlcanyísXàtivaSpain,Faculty of Medicine and DentistryUniversity of ValenciaValenciaSpain
| | | | - Adolfo Alonso‐Arroyo
- UISYS. Department of History of Science and Information ScienceSchool of Medicine and Dentistry, University of ValenciaValenciaSpain
| | - Antonio Vidal‐Infer
- UISYS. Department of History of Science and Information ScienceSchool of Medicine and Dentistry, University of ValenciaValenciaSpain
| | | |
Collapse
|
15
|
Zarei-Ghanavati S, Jafarpour S, Hassanzadeh S, Bakhtiari E, Daraee G, Monadi SD, Ziaei M. Changes in Corneal Biomechanical Properties After Small-Incision Lenticule Extraction and Photorefractive Keratectomy, Using a Noncontact Tonometer. Cornea 2022; 41:886-893. [PMID: 34690272 DOI: 10.1097/ico.0000000000002888] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/14/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The aim of this study was to evaluate and compare early corneal biomechanical changes after small-incision lenticule extraction (SMILE) and photorefractive keratectomy (PRK). METHODS The study comprised 74 patients eligible for refractive surgery, equally allocated to PRK (37 patients) and SMILE (37 patients). Corneal biomechanical properties were recorded and compared between the 2 groups at preoperatively and 3 months after surgery using a dynamic ultra-high-speed Scheimpflug camera equipped with a noncontact tonometer. RESULTS Both procedures significantly affected corneal biomechanical properties at 3 months after surgery. Patients in the PRK group showed significantly better results for deformation amplitude ratio (DA ratio) ( P = 0.03), maximum inverse radius (InvRadMax) ( P = 0.02), and A2 time ( P = 0.03). The mean changes in DA ratio, HC radius, InvRadMax, and Ambrosio relational thickness were significantly higher in the SMILE group in comparison with those of the PRK group (all, P < 0.05). In both groups, change in CCT was significantly correlated with changes in DA ratio and InvRadMax ( P < 0.05). CONCLUSIONSS Both SMILE and PRK refractive surgeries significantly altered corneal biomechanical properties but the changes were more prominent after SMILE.
Collapse
Affiliation(s)
- Siamak Zarei-Ghanavati
- Ophthalmology Department, Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Soheyla Jafarpour
- Ophthalmology Department, Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Samira Hassanzadeh
- Department of Optometry, Refractive Error Research Center, Paramedical College, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Elham Bakhtiari
- Department of ophthalmology, Eye Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Ghazaleh Daraee
- Student Research Committee, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; and
| | - Sahar Darabi Monadi
- Student Research Committee, School of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran; and
| | - Mohammed Ziaei
- Faculty of Medical and Health Sciences, Department of Ophthalmology, New Zealand National Eye Centre, University of Auckland, Auckland, New Zealand
| |
Collapse
|
16
|
Zhang D, Tian L, Zhang H, Zheng Y, Fu C, Zhai C, Jie Y, Li L. Differences of Corneal Biomechanics Among Thin Normal Cornea, Forme-Fruste Keratoconus, and Cornea After SMILE. Front Bioeng Biotechnol 2022; 10:861924. [PMID: 35646859 PMCID: PMC9136087 DOI: 10.3389/fbioe.2022.861924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 04/12/2022] [Indexed: 11/13/2022] Open
Abstract
Background: To compare the corneal biomechanics of thin normal cornea (TNC) with thinnest corneal thickness (TCT) (≤500 µm), forme-fruste keratoconus (FFKC) and cornea after small incision lenticule extraction (Post-SMILE) had their central corneal thickness (CCT) matched by Corneal Visualization Scheimpflug Technology (Corvis ST).Methods: CCT were matched in 23 eyes with FFKC, 23 eyes by SMILE in 3 months post-operatively, and 23 TNC eyes. The differences in corneal biomechanics by Corvis ST among the three groups were compared.Results: There was no significant difference in CCT among the three groups, and the biomechanically corrected intraocular pressure (bIOP) did not differ significantly among the three groups (all p > 0.05). There were significant differences in most DCR parameters between pre- and post-operatively (all p < 0.05). Compared with TNC, the values of corneal deflection amplitude during the first applanation (A1DA), length at the first applanation (A1L), corneal deflection amplitude during the second applanation (A2DA), and maximum deformation amplitude (DA) decreased in 3 months after SMILE (all p < 0.05), these values increased in the FFKC (all p < 0.05).Conclusion: The majority of the DCR parameters were different among the three groups. The parameters A1DA, A1L, A2DA, and DA may be different between TNC and Post-SMILE, TNC and FFKC, and Post-SMILE and FFKC.
Collapse
Affiliation(s)
- Di Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-based Precision Medicine, Capital Medical University, Beijing, China
| | - Lei Tian
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beijing Tongren Hospital, Beihang University and Capital Medical University, Beijing, China
| | - Haixia Zhang
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-based Precision Medicine, Capital Medical University, Beijing, China
| | - Yan Zheng
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Caiyun Fu
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Changbin Zhai
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- *Correspondence: Lin Li, ; Changbin Zhai, ; Ying Jie,
| | - Ying Jie
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Institute of Ophthalmology, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- *Correspondence: Lin Li, ; Changbin Zhai, ; Ying Jie,
| | - Lin Li
- School of Biomedical Engineering, Capital Medical University, Beijing, China
- Beijing Key Laboratory of Fundamental Research on Biomechanics in Clinical Application, Capital Medical University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-based Precision Medicine, Capital Medical University, Beijing, China
- *Correspondence: Lin Li, ; Changbin Zhai, ; Ying Jie,
| |
Collapse
|
17
|
Xin Y, Lopes BT, Wang J, Wu J, Zhu M, Jiang M, Miao Y, Lin H, Cao S, Zheng X, Eliasy A, Chen S, Wang Q, Ye Y, Bao F, Elsheikh A. Biomechanical Effects of tPRK, FS-LASIK, and SMILE on the Cornea. Front Bioeng Biotechnol 2022; 10:834270. [PMID: 35433653 PMCID: PMC9009506 DOI: 10.3389/fbioe.2022.834270] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Accepted: 02/15/2022] [Indexed: 11/17/2022] Open
Abstract
Purpose: The objective of this study is to evaluate the in vivo corneal biomechanical response to three laser refractive surgeries. Methods: Two hundred and twenty-seven patients who submitted to transepithelial photorefractive keratectomy (tPRK), femtosecond laser-assisted in-situ keratomileusis (FS-LASIK), or small-incision lenticule extraction (SMILE) were included in this study. All cases were examined with the Corvis ST preoperatively (up to 3 months) and postoperatively at 1, 3, and 6 months, and the differences in the main device parameters were assessed. The three groups were matched in age, gender ratio, corneal thickness, refractive error corrections, optical zone diameter, and intraocular pressure. They were also matched in the preoperative biomechanical metrics provided by the Corvis ST including stiffness parameter at first applanation (SP-A1), integrated inverse radius (IIR), deformation amplitude (DA), and deformation amplitude 2 mm away from apex and the apical deformation (DARatio2mm). Results: The results demonstrated a significant decrease post-operation in SP-A1 and significant increases in IIR, DA, and DARatio2mm (p < 0.05), all of which indicated reductions in overall corneal stiffness. Inter-procedure comparisons provided evidence that the smallest overall stiffness reduction was in the tPRK group, followed by the SMILE, and then the FS-LASIK group (p < 0.05). These results remained valid after correction for the change in CCT between pre and 6 months post-operation and for the percentage tissue altered. In all three surgery groups, higher degrees of refractive correction resulted in larger overall stiffness losses based on most of the biomechanical metrics. Conclusion: The corneal biomechanical response to the three surgery procedures varied significantly. With similar corneal thickness loss, the reductions in overall corneal stiffness were the highest in FS-LASIK and the lowest in tPRK.
Collapse
Affiliation(s)
- Yue Xin
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - Bernardo T. Lopes
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - JunJie Wang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Jie Wu
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - ManMan Zhu
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - MuChen Jiang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - YuanYuan Miao
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
| | - HuiNi Lin
- STU-CUHKJoint Shantou International Eye Center, Shantou, China
| | - Si Cao
- Wuhan Puren Hospital, Wuhan, China
| | - XiaoBo Zheng
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - ShiHao Chen
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
- *Correspondence: ShiHao Chen, ; YuFeng Ye, ; FangJun Bao,
| | - QinMei Wang
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
| | - YuFeng Ye
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- *Correspondence: ShiHao Chen, ; YuFeng Ye, ; FangJun Bao,
| | - FangJun Bao
- Eye Hospital, Wenzhou Medical University, Wenzhou, China
- The Institute of Ocular Biomechanics, Wenzhou Medical University, Wenzhou, China
- *Correspondence: ShiHao Chen, ; YuFeng Ye, ; FangJun Bao,
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
- National Institute for Health Research (NIHR) Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, United Kingdom
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China
| |
Collapse
|
18
|
Fuest M, Mehta JS. Advances in refractive corneal lenticule extraction. Taiwan J Ophthalmol 2021; 11:113-121. [PMID: 34295616 PMCID: PMC8259523 DOI: 10.4103/tjo.tjo_12_21] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 03/16/2021] [Indexed: 01/31/2023] Open
Abstract
Refractive errors are the leading cause of reversible visual impairment worldwide. In addition to the desired spectacle independence, refractive procedures can improve quality of life, working ability, and daily working performance. Refractive corneal lenticule extraction (RCLE) is a relatively new technique, dependent only on a femtosecond laser (FS). This leads to potential benefits over laser-assisted in situ keratomileusis (LASIK) including a quicker recovery of dry eye disease, a larger functional optical zone, and no flap-related complications. SMILE, available with the VisuMax FS (Carl Zeiss Meditec AG, Jena, Germany), is the most established RCLE application, offering visual and refractive outcomes comparable to LASIK. SmartSight (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany) and CLEAR (Ziemer Ophthalmic Systems AG, Port, Switzerland) are two new RCLE applications that received Conformité Européenne (CE) approval in 2020. In this article, we review refractive and visual outcomes, advantages, and disadvantages of RCLE and also report on the latest advances in RCLE systems.
Collapse
Affiliation(s)
- Matthias Fuest
- Department of Ophthalmology, RWTH Aachen University, Aachen, Germany
| | - Jodhbir S Mehta
- Tissue Engineering and Stem Cell Group, Singapore Eye Research Institute, Singapore.,Singapore National Eye Centre, Singapore.,Eye-Academic Clinical Program, Duke-National University of Singapore Graduate Medical School, Singapore.,School of Material Science and Engineering, Nanyang Technological University, Singapore
| |
Collapse
|
19
|
Abstract
The emergence of SMILE in the last decade has provided an alternative to LASIK for patients considering cornea laser refractive surgery. SMILE offers a novel approach using the femtosecond laser to create an intrastromal lenticule that can be removed through a small three to four millimeter incision.The purpose of this study is to review the recent literature on popular SMILE claims - reduced iatrogenic dry eye, better recovery of corneal sensation, and a biomechanically stronger cornea - summarize the published outcomes, and determine which claims are myths versus realities.SMILE is still in its infancy as a refractive technique in the US after recent USFDA approval for its treatment of myopia astigmatism in October 2018. Future randomized controlled studies are needed to compare its outcomes to LASIK, which has well-documented good visual outcomes, rapid postoperative recovery, and good safety profile.
Collapse
Affiliation(s)
- Grace Huang
- Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.,Boston Eye Group, Brookline, MA, USA
| | - Samir Melki
- Massachusetts Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.,Boston Eye Group, Brookline, MA, USA
| |
Collapse
|
20
|
Lanza M, De Rosa L, Sbordone S, Boccia R, Gironi Carnevale UA, Simonelli F. Analysis of Corneal Distortion after Myopic PRK. J Clin Med 2020; 10:jcm10010082. [PMID: 33379378 PMCID: PMC7794860 DOI: 10.3390/jcm10010082] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 12/14/2020] [Accepted: 12/24/2020] [Indexed: 01/22/2023] Open
Abstract
The purpose of the study is to evaluate the corneal biomechanical properties (CBP) and their behaviors after myopic refractive surgery both with Ocular Response Analyzer (ORA) and Corvis ST (CST). This retrospective study included 145 eyes of 145 patients with a mean age of 33.13 ± 9.24 years, who underwent myopic photorefractive keratectomy (PRK) for a refractive defect, measured as spherical equivalent, of mean −4.69 ± 2.04 D and have been evaluated before surgery and at 1, 3 and 6 months follow-up. Corneal hysteresis (CH) and corneal resistance factor (CRF) values significantly decreased after 1 month and remained statistically stable during further follow-ups. CST parameters had a different evolution: only second applanation time (AT2) differences showed a significant variation after 1 month that did not statistically change over time. Highest concavity deformation amplitude (HCDA), highest concavity peak distance (HCPD), first applanation time (AT1) and velocity (AV1) showed continuous significant differences both after 3 and after 6 months. This study suggests that after central surface ablation surgery, such as myopic PRK, corneal shape is remodeling, and its deformation parameters are going to change even at 6 months follow-up. This indicates that it should be important to evaluate refractive surgery patients during a longer follow-up because this could allow earlier diagnosis and better management of late-onset complications.
Collapse
|
21
|
Yesilkaya C, Arıcı M, Yıldırım Y, Agca A, Demircan A, Taskapılı M. Short and long term outcomes after small-incision lenticule extraction: A tertiary referral centre experience. J Fr Ophtalmol 2020; 43:753-760. [PMID: 32620412 DOI: 10.1016/j.jfo.2019.11.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 09/29/2019] [Accepted: 11/13/2019] [Indexed: 10/24/2022]
Abstract
PURPOSE The objective of this study is to evaluate the preoperative and short- and long-term postoperative results in terms of visual acuity, refractive error, and corneal wavefront aberrations in patients with myopia and myopic astigmatism undergoing small incision lenticule extraction (SMILE). METHODS Seventy-nine eyes of 52 myopes with or without astigmatism (41 right and 38 left) were enrolled in this retrospective study. The measurements included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), spherical equivalent (SE) and wavefront aberrations. All the measurements before and after SMILE surgery were systematically recorded. RESULTS Mean preoperative UDVA was 1.19±0.24 logMAR and improved to 0.06±0.17 logMAR at the 3-year postoperative follow-up. At the conclusion of the 3-year follow-up, UDVA was better than or equal to 20/20 and 20/25 in 73% and 84% of eyes, respectively. At 1 month postoperatively, CDVA was 0.05±0.23 logMAR and significantly lower than the preoperative CDVA, 0.02±0.04 log MAR (P>0.05). However, at 1 year and 3 years after surgery, CDVA showed a significant increase compared to preoperative CDVA. At the conclusion of the 3-year follow-up, SE was -0.47 D, and 69.6% and 83.5% of the eyes were within±0.50 D and±1.00 D, respectively, of the intended correction. HOA's, coma, and spherical aberration increased significantly. No significant change in trefoil was detected. CONCLUSION This study showed that SMILE produces a stable, safe outcome for surgical treatment of myopia and myopic astigmatism.
Collapse
Affiliation(s)
- C Yesilkaya
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey.
| | - M Arıcı
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - Y Yıldırım
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - A Agca
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - A Demircan
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| | - M Taskapılı
- Department of Ophthalmology, Health Sciences University, Beyoğlu Eye Research and Training Hospital, Istanbul, Turkey
| |
Collapse
|
22
|
Effectiveness of 4 tonometers in measuring IOP after femtosecond laser-assisted LASIK, SMILE, and transepithelial photorefractive keratectomy. J Cataract Refract Surg 2020; 46:967-974. [PMID: 32271270 DOI: 10.1097/j.jcrs.0000000000000204] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE To test the performance of 4 tonometers in estimating intraocular pressure (IOP) after 3 forms of refractive surgery. SETTING Eye Hospital, Wenzhou Medical University, China. DESIGN Prospective case series. METHODS Patients matched for preoperative age, corneal thickness, and myopic correction enrolled for femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK), small-incision lenticule extraction (SMILE), or transepithelial photorefractive keratectomy (tPRK) were included in the study. For each patient, 4 measurements of IOP were obtained preoperatively and 3 months postoperatively, using the Goldmann applanation tonometer (GAT-IOP), the Dynamic Contour Tonometer (DCT-IOP), corneal-compensated IOP (IOPcc) from the Ocular Response Analyzer, and biomechanically corrected IOP (bIOP) from the Corvis ST. Overall corneal stiffness was also estimated based on the stiffness parameter (SP-A1) provided by the Corvis ST. RESULTS The study included 144 eyes of 144 patients. Among the 3 procedures, the smallest variances between preoperative and postoperative IOP estimates and SP-A1 values were observed with the tPRK, followed by SMILE and FS-LASIK. In the tPRK group, no significant differences were observed in both bIOP (-0.18 ± 1.63 mm Hg) and DCT-IOP (-.64 ± 2.34 mm Hg), whereas they were larger and significant in GAT-IOP (-1.78 ± 2.29 mm Hg) and IOPcc (-2.77 ± 1.84 mm Hg). In FS-LASIK and SMILE groups, although there were similar significant reductions in IOP postoperatively, these reductions were still lower in bIOP and DCT-IOP than those in GAT-IOP and IOPcc. CONCLUSIONS The bIOP and DCT-IOP were the least affected IOP estimates between the 3 refractive surgery procedures considered. It was evident that tPRK produced significantly smaller reductions in IOP readings than did FS-LASIK and SMILE.
Collapse
|
23
|
Siedlecki J, Siedlecki M, Luft N, Kook D, Meyer B, Bechmann M, Wiltfang R, Sekundo W, Priglinger SG, Dirisamer M. Surface Ablation Versus CIRCLE for Myopic Enhancement After SMILE: A Matched Comparative Study. J Refract Surg 2019; 35:294-300. [PMID: 31059578 DOI: 10.3928/1081597x-20190416-02] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 04/15/2019] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the outcomes of enhancement after small incision lenticule extraction (SMILE) using surface ablation versus the VisuMax CIRCLE option (Carl Zeiss Meditec AG, Jena, Germany), which converts the SMILE cap into a femtosecond laser-assisted laser in situ keratomileusis flap. METHODS The databases of the SMILE Eyes centers in Munich, Marburg, and Cologne, Germany, and Linz, Austria, were screened for eyes that had undergone enhancement using surface ablation with mitomycin C or CIRCLE. Eyes from both enhancement methods suitable for a retrospective matched analysis were identified based on pre-SMILE and pre-enhancement mean refractive spherical equivalent (MRSE), astigmatism, age, and corrected and uncorrected distance visual acuity (CDVA/UDVA). Refractive and functional outcomes were compared after a follow-up of 3 months. RESULTS After the application of the matching criteria on 2,803 SMILE procedures, 24 eyes (12 in each group) with a follow-up of 3 months or longer were available for analysis. Enhancement was performed after a mean 9.7 ± 7.2 (surface ablation) and 11.0 ± 4.4 (CIRCLE) months for a residual MRSE of -0.91 ± 0.55 (surface ablation) and -0.90 ± 0.61 (CIRCLE) diopters. At 3 months, residual MRSE showed comparable accuracy with -0.07 ± 0.19 (surface ablation) and 0.04 ± 0.22 (CIRCLE) diopters (P = .18). UDVA improvement was similar to a final value of 0.02 ± 0.10 (surface ablation) versus 0.03 ± 0.07 (CIRCLE) logMAR (P = .78). Only one eye in the surface ablation group and no eye in the CIRCLE group lost one line of CDVA. At 3 months, the safety (surface ablation: 1.00, CIRCLE: 1.06; P = .36) and efficacy (surface ablation: 0.95, CIRCLE: 1.03; P = .36) indices were equivalent. In terms of speed of visual recovery, at week 1 UDVA and CDVA were significantly better after CIRCLE than surface ablation (P = .008 and .002, respectively). CONCLUSIONS In this first study directly comparing surface ablation versus CIRCLE enhancement after SMILE, both methods yielded comparable results at 3 months. However, CIRCLE re-treated eyes showed a markedly increased speed of recovery concerning UDVA and CDVA compared to surface ablation. [J Refract Surg. 2019;35(5):294-300.].
Collapse
|