For: Rutkunas V, Larsson C, Vult von Steyern P, Mangano F, Gedrimiene A. Clinical and laboratory passive fit assessment of implant-supported zirconia restorations fabricated using conventional and digital workflow. Clin Implant Dent Relat Res 2020;22:237-245. [PMID: 32026603 DOI: 10.1111/cid.12885] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2019] [Revised: 12/24/2019] [Accepted: 01/17/2020] [Indexed: 02/04/2023]
Number Cited by Other Article(s)
1
Fakhr MWZF, Alansary H, Hassanien EEY. Internal fit and marginal adaptation of all-ceramic implant-supported hybrid abutment crowns with custom-milled screw-channels on Titanium-base: in-vitro study. BMC Oral Health 2024;24:1073. [PMID: 39261788 PMCID: PMC11391652 DOI: 10.1186/s12903-024-04810-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 08/26/2024] [Indexed: 09/13/2024]  Open
2
Rutkūnas V, Auškalnis L, Pletkus J. Intraoral scanners in implant prosthodontics. A narrative review. J Dent 2024;148:105152. [PMID: 38909643 DOI: 10.1016/j.jdent.2024.105152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 05/15/2024] [Accepted: 06/21/2024] [Indexed: 06/25/2024]  Open
3
Fu XJ, Liu M, Liu BL, Tonetti MS, Shi JY, Lai HC. Accuracy of intraoral scan with prefabricated aids and stereophotogrammetry compared with open tray impressions for complete-arch implant-supported prosthesis: A clinical study. Clin Oral Implants Res 2024;35:830-840. [PMID: 37746813 DOI: 10.1111/clr.14183] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Revised: 09/01/2023] [Accepted: 09/10/2023] [Indexed: 09/26/2023]
4
Eldin BSG, Talaat IA, Nawar NHH, Mohamed AMA. Effect of different fabrication workflows on the passive fit of screw-retained bar splinting two interforaminal implants: a parallel blinded randomised clinical trial. BMC Oral Health 2024;24:410. [PMID: 38566034 PMCID: PMC10985940 DOI: 10.1186/s12903-024-04157-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2023] [Accepted: 03/18/2024] [Indexed: 04/04/2024]  Open
5
Zou J, Li L. An indirect method of verifying passive fit of complete arch implant-supported frameworks fabricated from photogrammetry scans. J Prosthet Dent 2024;131:756-759. [PMID: 37357084 DOI: 10.1016/j.prosdent.2023.04.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/21/2023] [Accepted: 04/21/2023] [Indexed: 06/27/2023]
6
Klein M, Tuminelli FJ, Sallustio A, Giglio GD, Lerner H, Berg RW, Waltuch A. Full-arch restoration with the NEXUS IOS® system: A retrospective clinical evaluation of 37 restorations after a one year of follow-up. J Dent 2023;139:104741. [PMID: 37832627 DOI: 10.1016/j.jdent.2023.104741] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 10/15/2023]  Open
7
Shely A, Lugassy D, Rosner O, Zanziper E, Nissan J, Rachmiel S, Khoury Y, Ben-Izhack G. The Influence of Laboratory Scanner versus Intra-Oral Scanner on Determining Axes and Distances between Three Implants in a Straight Line by Using Two Different Intraoral Scan Bodies: A Pilot In Vitro Study. J Clin Med 2023;12:6644. [PMID: 37892783 PMCID: PMC10607023 DOI: 10.3390/jcm12206644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 10/29/2023]  Open
8
Zhang YJ, Qian SJ, Lai HC, Shi JY. Accuracy of photogrammetric imaging versus conventional impressions for complete arch implant-supported fixed dental prostheses: A comparative clinical study. J Prosthet Dent 2023;130:212-218. [PMID: 34776266 DOI: 10.1016/j.prosdent.2021.09.035] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/29/2021] [Accepted: 09/29/2021] [Indexed: 11/18/2022]
9
Rutkunas V, Bilius V, Simonaitis T, Auskalnis L, Jurgilevicius J, Akulauskas M. The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study. J Dent 2022;126:104267. [PMID: 36029970 DOI: 10.1016/j.jdent.2022.104267] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 08/03/2022] [Accepted: 08/18/2022] [Indexed: 11/16/2022]  Open
10
Ochoa-López G, Cascos R, Antonaya-Martín JL, Revilla-León M, Gómez-Polo M. Influence of ambient light conditions on the accuracy and scanning time of seven intraoral scanners in complete-arch implant scans. J Dent 2022;121:104138. [DOI: 10.1016/j.jdent.2022.104138] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/24/2022] [Accepted: 04/20/2022] [Indexed: 10/18/2022]  Open
11
Suphangul S, Rokaya D, Kanchanasobhana C, Rungsiyakull P, Chaijareenont P. PEEK Biomaterial in Long-Term Provisional Implant Restorations: A Review. J Funct Biomater 2022;13:jfb13020033. [PMID: 35466215 PMCID: PMC9036277 DOI: 10.3390/jfb13020033] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 03/17/2022] [Accepted: 03/21/2022] [Indexed: 02/06/2023]  Open
12
Rutkunas V, Gedrimiene A, Akulauskas M, Fehmer V, Sailer I, Jegelevicius D. In vitro and in vivo accuracy of full-arch digital implant impressions. Clin Oral Implants Res 2021;32:1444-1454. [PMID: 34543478 DOI: 10.1111/clr.13844] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 07/15/2021] [Accepted: 07/19/2021] [Indexed: 11/29/2022]
13
Michelinakis G, Apostolakis D, Kamposiora P, Papavasiliou G, Özcan M. The direct digital workflow in fixed implant prosthodontics: a narrative review. BMC Oral Health 2021;21:37. [PMID: 33478459 PMCID: PMC7819204 DOI: 10.1186/s12903-021-01398-2] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Accepted: 01/13/2021] [Indexed: 12/17/2022]  Open
14
Kim J, Son K, Lee KB. Displacement of scan body during screw tightening: A comparative in vitro study. J Adv Prosthodont 2020;12:307-315. [PMID: 33149852 PMCID: PMC7604234 DOI: 10.4047/jap.2020.12.5.307] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Revised: 05/25/2020] [Accepted: 06/01/2020] [Indexed: 11/08/2022]  Open
15
Congruence between Meshes and Library Files of Implant Scanbodies: An In Vitro Study Comparing Five Intraoral Scanners. J Clin Med 2020;9:jcm9072174. [PMID: 32660070 PMCID: PMC7408706 DOI: 10.3390/jcm9072174] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 07/07/2020] [Accepted: 07/08/2020] [Indexed: 12/17/2022]  Open