1
|
Cortellini D, Canale A, Schmitz JH, Valenti M, Valenti A. A digital protocol for the fabrication of anatomic-contour implant zirconia crowns directly screwed on external hexagonal implant connections without the interposition of a Ti-base component. J Prosthet Dent 2024; 132:1124-1127. [PMID: 36898867 DOI: 10.1016/j.prosdent.2023.01.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 01/15/2023] [Accepted: 01/18/2023] [Indexed: 03/12/2023]
Abstract
A straightforward and effective restorative option is proposed for implant-supported fixed prostheses with external connections by using monolithic zirconia without the interposition of a Ti-base component. The technique is based on a modification of the Brånemark connection used to link metal-ceramic or metal-composite resin restorations directly to the implant.
Collapse
|
2
|
Maceiras L, Liñares A, Nóvoa L, Batalla P, Mareque S, Pérez J, Blanco J. Marginal changes at bone-level implants supporting dental prostheses with or without intermediate standardised abutments after 36 months: Randomised controlled clinical trial. Clin Oral Implants Res 2024; 35:1072-1080. [PMID: 38797975 DOI: 10.1111/clr.14297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 03/18/2024] [Accepted: 05/13/2024] [Indexed: 05/29/2024]
Abstract
OBJECTIVE The objective of this study is to evaluate the changes at marginal bone level at implants restored with screw-retained prosthesis connected directly to the implants or with an intermediate abutment, after 3-year follow-up. MATERIAL AND METHODS Thirty-six partially edentulous patients received 72 implants. Each patient received 2 implants and a 2-4-unit screw-retained implant-prosthesis. The test group implants received a screw-retained prosthesis connected directly to the implant shoulder, the control group prosthesis were connected through a 3-mm standardised intermediate abutment. Clinical and radiological data were recorded at baseline and at 6-, 12-, and 36-month follow-up. RESULTS At 36 months, the mean marginal bone loss was 0.13 ± 0.18 mm for the control group and 0.20 ± 0.24 for the test group, with no significant differences between groups (p > .05). Clinical variables (Probing Pocket Depth, Bleeding on Probing and Plaque Index) at 36 months also showed no significant difference between groups. Minor complications frequency was 6.7% in the control group and 5.3% in test group. None of the groups suffered from mayor complications. Patient Reported Outcomes (PROs) showed a General Satisfaction mean score in the control group of 9.40 (SD 0.82) and 9.37 (SD 1.06) in the test group with no significant differences between groups. CONCLUSIONS Bone-level implants restored with screw-retained partial prostheses with or without intermediate abutments showed similar radiographic and clinical outcomes after 3 years.
Collapse
Affiliation(s)
- Lucía Maceiras
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Antonio Liñares
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
- Medical-Surgical Odontology (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Lourdes Nóvoa
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Pilar Batalla
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Santiago Mareque
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | | | - Juan Blanco
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
- Medical-Surgical Odontology (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| |
Collapse
|
3
|
Angermair J, Iglhaut G, Meyenberg K, Wiest W, Rack A, Zabler S, Fretwurst T, Nelson K, Kernen F. In vitro assessment of internal implant-abutment connections with different cone angles under static loading using synchrotron-based radiation. BMC Oral Health 2024; 24:396. [PMID: 38549137 PMCID: PMC10976688 DOI: 10.1186/s12903-024-04156-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Accepted: 03/18/2024] [Indexed: 04/01/2024] Open
Abstract
BACKGROUND The stability of implant-abutment connection is crucial to minimize mechanical and biological complications. Therefore, an assessment of the microgap behavior and abutment displacement in different implant-abutment designs was performed. METHODS Four implant systems were tested, three with a conical implant-abutment connection based on friction fit and a cone angle < 12 ° (Medentika, Medentis, NobelActive) and a system with an angulated connection (< 40°) (Semados). In different static loading conditions (30 N - 90º, 100 N - 90º, 200 N - 30º) the microgap and abutment displacement was evaluated using synchrotron-based microtomography and phase-contrast radioscopy with numerical forward simulation of the optical Fresnel propagation yielding an accuracy down to 0.1 μm. RESULTS Microgaps were present in all implant systems prior to loading (0.15-9 μm). Values increased with mounting force and angle up to 40.5 μm at an off axis loading of 100 N in a 90° angle. CONCLUSIONS In contrast to the implant-abutment connection with a large cone angle (45°), the conical connections based on a friction fit (small cone angles with < 12°) demonstrated an abutment displacement which resulted in a deformation of the outer implant wall. The design of the implant-abutment connection seems to be crucial for the force distribution on the implant wall which might influence peri-implant bone stability.
Collapse
Affiliation(s)
| | - Gerhard Iglhaut
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany
| | | | - Wolfram Wiest
- Chair of X-ray Microscopy LRM, University Würzburg, 97074, Würzburg, Germany
| | - Alexander Rack
- Experiments Division, ESRF - The European Synchrotron, Grenoble, France
| | - Simon Zabler
- Deggendorf Institute of Technology DIT, Dieter-Görlitz-Platz 2, 94469, Deggendorf, Germany
| | - Tobias Fretwurst
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany
| | - Katja Nelson
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany
| | - Florian Kernen
- Department of Oral and Maxillofacial Surgery, Translational Implantology, Medical Center, Faculty of Medicine, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg, Germany.
| |
Collapse
|
4
|
Sun M, Shui Y, Zhang Y, Ma R, Zhao Y, Chen H, Yu P, Li Z, Wu T, Yu H. Influence of Abutment Screw-Tightening Methods on the Screw Joint: Immediate and Long-Term Stability. Int J Dent 2024; 2024:5768318. [PMID: 38264680 PMCID: PMC10805556 DOI: 10.1155/2024/5768318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/12/2023] [Accepted: 12/20/2023] [Indexed: 01/25/2024] Open
Abstract
Objective To evaluate the influence of screw-tightening methods on the immediate and long-term stability of dental implant screw joints. Methodology. A total of 150 implants of three different implant systems with different diameters were used in this study. Each group was divided into three subgroups (n = 5), according to the tightening methods (A-tightening with recommended torque and retorque after 10 min; B-tightening with recommended torque, then loosening and immediate retorque; C-tightening with recommended torque only once). The operating time of tightening the assemblies was recorded. Ten minutes later, the immediate removal torque (IRT) (Ncm) was measured. After retightening the assemblies, a dynamic load between 20 and 200 N was applied for 105 cycles, and the postloading removal torque (PRT) (Ncm) was measured. Scanning electron microscopy (SEM) was used to observe the surface topography of the screws. Results For different types of implants, the IRTs were 11.92 ± 1.04-34.12 ± 0.36 Ncm for method A, 11.64 ± 0.57-33.96 ± 0.29 Ncm for method B, and 10.30 ± 0.41-31.62 ± 0.52 Ncm for method C, and the IRTs of methods A and B were 6.28%-21.58% higher than that of method C (P ≤ 0.046). The PRTs were 4.08 ± 0.77-29.86 ± 0.65 Ncm for method A, 4.04 ± 0.40-29.60 ± 0.36 Ncm for method B, and 2.98 ± 0.26-26.38 ± 0.59 Ncm for method C, and the PRTs of methods A and B were 11.77%-44.87% higher than that of method C (P ≤ 0.016). The removal torque loss rates of methods A (12.49% ± 0.99%-65.88% ± 4.83%) and B (12.84% ± 0.96%-65.35% ± 1.95%) were 3.04%-7.74% lower than that of method C (16.58% ± 0.56%-71.10% ± 1.58%) (P ≤ 0.017). The operating time of method A was much longer than those of methods B and C (P < 0.001). The structural integrity disruption of the screw thread was observed according to the SEM results in all postloading groups. Conclusions Method B (torquing and then loosening and immediate retorquing) increases the screw joint immediate stability by 6.28%-21.58% and the long-term stability by 11.77%-44.87% compared with method C (torquing only once), has comparable screw joint stability compared with method A (retorquing after 10 min), saves time and is recommended in clinical settings.
Collapse
Affiliation(s)
- Manlin Sun
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yusen Shui
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yuqiang Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ruiyang Ma
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yuwei Zhao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Hongyu Chen
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Ping Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Zhi Li
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Tingting Wu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Haiyang Yu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
5
|
Mitra D, Gurav P, Rodrigues S, Khobragade B, Mahajan A. Evaluation of stress distribution in and around dental implants using three different implant-abutment interfaces with platform-switched and non-platform-switched abutments: A three-dimensional finite element analysis. J Dent Res Dent Clin Dent Prospects 2023; 17:256-264. [PMID: 38584996 PMCID: PMC10998169 DOI: 10.34172/joddd.2023.40723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Accepted: 12/07/2023] [Indexed: 04/09/2024] Open
Abstract
Background A key factor for the success or failure of an implant is how the stresses are transferred to the surrounding bone. The implant‒abutment connection (IAC) is paramount for implant success. The purpose of this finite element analysis (FEA) study was to evaluate the stress distribution in and around three different implant‒abutment interfaces with platform-switched and platform-matched abutments using the finite element method (FEM). Methods Three distinct types of IAC were selected: tri-channel internal connection, conical connection, and internal hex connection. Six models were generated, three in platform-switched and three in non-platform-switched configuration. Computer-Aided Three-Dimensional Interactive Application (CATIA) V5 R20 software was used to generate virtual models of the implants and the mandible. The models were transferred to Analysis of Systems (ANSYS) 15.0 software, in which the models were meshed and underwent FEA. Results On the crestal bone, the highest von Mises stresses in platform-switched abutments were noticed in the internal hex implant‒abutment system (370 MPa), followed by the tri-channel implant‒abutment system (190 MPa) and conical implant‒abutment system (110 MPa). On the implant and the abutment screw, the highest von Mises stresses were observed in the internal hex implant‒abutment system, followed by the conical implant abutment system and tri-channel implant‒abutment system. Platform-switched implants had a more favorable stress distribution on crestal bone. Conclusion Within the constraints of the current study, the internal hex connection exhibited the highest stress. In contrast, the conical abutment connection with platform switching configuration had more favorable stress distribution in crestal bone than other implant abutment systems.
Collapse
Affiliation(s)
- Dipika Mitra
- Department of Periodontology, TPCT’s Terna Dental College & Hospital, Navi Mumbai, Maharashtra, India
| | - Prachi Gurav
- Department of Periodontics and Implantology Terna Dental College & Hospital, Navi Mumbai, Maharashtra, India
| | - Silvia Rodrigues
- Department of Periodontics and Implantology Terna Dental College & Hospital, Navi Mumbai, Maharashtra, India
| | - Bela Khobragade
- Department of Periodontics and Implantology Terna Dental College & Hospital, Navi Mumbai, Maharashtra, India
| | - Amruta Mahajan
- Department of Periodontics and Implantology Terna Dental College & Hospital, Navi Mumbai, Maharashtra, India
| |
Collapse
|
6
|
Kensara A, Saito H, Mongodin EF, Masri R. Microbiological profile of peri-implantitis: Analyses of microbiome within dental implants. J Prosthodont 2023; 32:783-792. [PMID: 36691777 DOI: 10.1111/jopr.13653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/12/2023] [Indexed: 01/25/2023] Open
Abstract
PURPOSE To characterize the microbiome composition within dental implants of peri-implantitis subjects and healthy controls using 16S rRNA gene sequencing. MATERIALS AND METHODS Twenty-three subjects with healthy (n = 11 implants) and diseased (peri-implantitis, n = 21) implants were included in this controlled clinical cross-sectional study. Samples were obtained from internal surfaces of dental implants using sterile paper points for microbiological analysis. DNA was extracted, and the16S rRNA gene was amplified using universal primers targeting the V3-V4 regions. The resulting 16S polymerize chain reaction amplicons were sequenced on Illumina MiSeq, and the sequences were processed using DADA2 and the Human Oral Microbiome Database (HOMD) as references. Alpha and Beta diversity, as well as core microbiome and differential abundance analyses were then performed using the MicrobiomeAnalyst workflow. RESULTS A significant increase in microbial diversity was observed in the internal implant surface of healthy implants compared with the internal surfaces of peri-implantitis (Shannon p = 0.02). Bacterial community structure was significantly different among groups (p = 0.012). High levels of Gram-positive bacteria were detected inside implants with peri-implantitis compared to healthy implants, especially Enterococci. CONCLUSIONS There is a shift in bacterial diversity inside implants with peri-implantitis from the healthy control. The microbial colonization within that space might contribute to the etiology of peri-implant disease.
Collapse
Affiliation(s)
- Anmar Kensara
- Department of Restorative Dentistry, College of Dentistry, Umm Al Qura University, Makkah, Saudi Arabia
- Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, Maryland, USA
| | - Hanae Saito
- Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, Maryland, USA
| | - Emmanuel F Mongodin
- Institute for Genome Sciences, School of Medicine, University of Maryland, Baltimore, Maryland, USA
| | - Radi Masri
- Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, Maryland, USA
| |
Collapse
|
7
|
Pera F, Carossa M, Bagnasco F, Crupi A, Ambrogio G, Isola G, Menini M, Pesce P. Comparison between Bone-Level and Tissue-Level Implants in Immediate-Loading Full-Arch Rehabilitations: A Retrospective Multi-Center 1-Year Follow-Up Study. PROSTHESIS 2023; 5:1301-1311. [DOI: 10.3390/prosthesis5040089] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/01/2024]
Abstract
The objective of the present retrospective multi-center study was to analyze the outcomes of bone-level (BL) implants and tissue-level (TL) implants in immediate-loading full-arch rehabilitations. Patients who were previously rehabilitated with full-arch immediate-loading rehabilitations with either BL or TL implants were considered. Data regarding implant survival rate, marginal bone loss (MBL), peri-implant probing depth (PPD), plaque index (PI), and bleeding on probing (BOP) were recorded, and the 1-year follow-up data were statistically analyzed between the two groups. In total, 38 patients were evaluated for a total implant number of 156 (n = 80 TL implants and n = 76 BL implants). An implant survival rate of 97.37% was recoded for the BL group while an implant survival rate of 100% was noted for the TL group. A total MBL of 1.324 ± 0.64 mm was recorded for BL implants, while a total MBL of 1.194 ± 0.30 mm was recorded for TL implants. A statistically significant difference was highlighted regarding MBL at the mesial aspect (p = 0.01552) of the implants, with BL implants presenting with higher MBL. Within the range of acceptable healthy values, a statistically significant difference was also highlighted regarding BOP (p < 0.00001), with TL implants presenting higher values. No statistically significant difference (p > 0.05) was recorded for any of the other variables analyzed. Within the limitations of the present retrospective study, both TL and BL implants seem to provide good clinical outcomes after a 12-month observational period when employed in immediate-loading full-arch rehabilitation.
Collapse
Affiliation(s)
- Francesco Pera
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, 10126 Turin, Italy
| | - Massimo Carossa
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, 10126 Turin, Italy
| | - Francesco Bagnasco
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Armando Crupi
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, 10126 Turin, Italy
| | - Giulia Ambrogio
- Department of Surgical Sciences, C.I.R. Dental School, University of Turin, 10126 Turin, Italy
| | - Gaetano Isola
- Unit of Periodontology, Department of General Surgery and Surgical-Medical Specialties, University of Catania, 95124 Catania, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, 16132 Genoa, Italy
| |
Collapse
|
8
|
Pera F, Pesce P, Menini M, Fanelli F, Kim BC, Zhurakivska K, Mayer Y, Isola G, Cianciotta G, Crupi A, Ambrogio G, Scotti N, Carossa M. Immediate loading full-arch rehabilitation using transmucosal tissue-level implants with different variables associated: a one-year observational study. Minerva Dent Oral Sci 2023; 72:230-238. [PMID: 37194244 DOI: 10.23736/s2724-6329.23.04782-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
BACKGROUND The aim of the present observational study was to investigate the application of transmucosal tissue-level implants in immediate loading full-arch rehabilitation with different variables associated. METHODS Patients needing a full-arch implant rehabilitation were recruited and rehabilitated with four transmucosal tissue level implants. Data related to implants' diameters and lengths, jaw distributions, and presence of angulated abutments were collected. The following outcomes were evaluated: survival rate, marginal bone loss (MBL), Plaque Index (PI), bleeding on probing (BoP), probing depth (PD). Descriptive statistical analysis was reported and univariate linear regression models were built to assess a significant correlation between MBL and the different implant related factors. RESULTS Twenty patients were rehabilitated for a total implant number of 80; 11 rehabilitations were performed on the maxilla, while 9 were performed on the mandible; 48 implants presented a 3.8 mm diameter and 32 implants presented a 4.25 mm diameter. Implants length varied between 10 to 15 mm; 40 tilted implants were connected to angulated abutment, while 40 straight implants were connected directly to the prostheses (no abutments). At the one year follow-up visit no implants failed resulting in an implant survival rate of 100%. The overall MBL was 1.19±0.30 mm. No statistically significant difference (P>0.05) was highlighted among any of the subgroups analyzed. CONCLUSIONS Despite different variables associated, tissue level implants seem to represent a valid option when applied in immediate loading full-arch rehabilitation. Further research and longer observational periods are encouraged to confirm the result.
Collapse
Affiliation(s)
- Francesco Pera
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - Francesco Fanelli
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Byung-Chan Kim
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Khrystyna Zhurakivska
- Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy
| | - Yaniv Mayer
- School of Graduate Dentistry, Health Care Campus Rambam, Haifa, Israel
| | - Gaetano Isola
- School of Dentistry, Department of General Surgery and Surgical-Medical Specialties, University of Catania, Catania, Italy
| | - Giulia Cianciotta
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Armando Crupi
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Giulia Ambrogio
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Nicola Scotti
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy
| | - Massimo Carossa
- C.I.R. Dental School, Department of Surgical Sciences, University of Turin, Turin, Italy -
| |
Collapse
|
9
|
Lafuente-Ibáñez-de-Mendoza I, Marichalar-Mendia X, García-De-La-Fuente AM, Quindós-Andrés G, Eraso-Barrio E, Martínez-Conde-Llamosas R, Fernández-Jiménez A, Aguirre-Urizar JM. Presence and implication of Candida spp. in patients with peri-implantitis enrolled in a supportive peri-implant therapy program of the Basque Country (Spain). A case-control study. Clin Implant Dent Relat Res 2023; 25:938-947. [PMID: 37259674 DOI: 10.1111/cid.13226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/17/2023] [Accepted: 05/12/2023] [Indexed: 06/02/2023]
Abstract
INTRODUCTION The peri-implant sulcus is a good niche for infectious colonization such as Candida spp. In this study, the level of Candida spp. fungal colonization is analyzed in patients with peri-implantitis under supportive peri-implant therapy, as well as its correlation with the main clinicopathological data. METHODS A case-control study was carried out on 161 patients treated with dental implants, 80 with PI and 81 without PI, which corresponded to 91 women and 70 men, whose mean age was 60.90 years. A specific protocol was completed for the clinical and implant data. Microbiological samples were taken by oral rinse and with paper tips from the peri-implant sulcus. For the quantitative and qualitative analysis Candida Chromogenic Agar/CONDA plates were incubated for 72 h at 36 + 1°C. Fungal growth was considered active when having more than 50 CFU. Specific Candida spp. cultures were later confirmed by API ID 32C and PCR. RESULTS Fungal growth was achieved in 28% of oral rinse and 6.75% of peri-implant fluid samples. No significant differences were recognized between study groups. Most of the cultures (>65%) showed more than 50 CFU. The most frequent species were Candida albicans and Candida parapsilosis. There was no association between different PI risk factors and fungal data. The presence of Candida spp. in the oral cavity of patients with dental implants was related to total edentulism and the use of implant-fixed complete prosthesis implant-retained removable prosthesis. CONCLUSIONS These results suggest that there is no link between PI and presence of Candida in patients with dental implants undergoing regular supportive periodontal therapy.
Collapse
Affiliation(s)
| | - Xabier Marichalar-Mendia
- Department of Nursery I, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| | - Ana María García-De-La-Fuente
- Department of Stomatology II, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| | - Guillermo Quindós-Andrés
- Department of Immunology, Microbiology, Parasitology, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| | - Elena Eraso-Barrio
- Department of Immunology, Microbiology, Parasitology, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| | | | - Aitziber Fernández-Jiménez
- Department of Stomatology II, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| | - José Manuel Aguirre-Urizar
- Department of Stomatology II, Faculty of Medicine and Nursery, University of the Basque Country (UPV/EHU), Leioa, Spain
| |
Collapse
|
10
|
Kunrath MF, Gerhardt MDN. Trans-mucosal platforms for dental implants: Strategies to induce muco-integration and shield peri-implant diseases. Dent Mater 2023; 39:846-859. [PMID: 37537095 DOI: 10.1016/j.dental.2023.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 07/19/2023] [Accepted: 07/26/2023] [Indexed: 08/05/2023]
Abstract
OBJECTIVES Trans-mucosal platforms connecting the bone-anchored implants to the prosthetic teeth are essential for the success of oral rehabilitation in implant dentistry. This region promotes a challenging environment for the successfulness of dental components due to the transitional characteristics between soft and hard tissues, the presence of bacteria, and mechanical forces. This review explored the most current approaches to modify trans-mucosal components in terms of macro-design and surface properties. METHODS This critical review article revised intensely the literature until July 2023 to demonstrate, discuss, and summarize the current knowledge about marketable and innovative trans-mucosal components for dental implants. RESULTS A large number of dental implant brands have promoted the development of several implant-abutment designs in the clinical market. The progress of abutment designs shows an optimistic reduction of bacteria colonization underlying the implant-abutment gap, although, not completely inhibited. Fundamental and preclinical studies have demonstrated promising outcomes for altered-surface properties targeting antibacterial properties and soft tissue sealing. Nanotopographies, biomimetic coatings, and antibiotic-release properties have been shown to be able to modulate, align, orient soft tissue cells, and induce a reduction in biofilm formation, suggesting superior abilities compared to the current trans-mucosal platforms available on the market. SIGNIFICANCE Future clinical implant-abutments show the possibility to reduce peri-implant diseases and fortify soft tissue interaction with the implant-substrate, defending the implant system from bacteria invasion. However, the absence of technologies translated to commercial stages reveals the need for findings to "bridge the gap" between scientific evidences published and applied science in the industry.
Collapse
Affiliation(s)
- Marcel F Kunrath
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, P.O. Box 412, SE 405 30 Göteborg, Sweden; School of Health and Life Sciences, Post-Graduate Program in Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, RS, Brazil; School of Technology, Post-Graduate Program in Materials Technology and Engineering, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, RS, Brazil.
| | - Maurício do N Gerhardt
- School of Health and Life Sciences, Post-Graduate Program in Dentistry, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| |
Collapse
|
11
|
Jervøe-Storm PM, Jepsen S, Marder M, Kraus D, Stoilov M, Enkling N. Prevention of internal bacterial colonization of dental implants: A comparative longitudinal observational study. Clin Oral Implants Res 2023; 34:979-986. [PMID: 37394702 DOI: 10.1111/clr.14124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 05/17/2023] [Accepted: 06/21/2023] [Indexed: 07/04/2023]
Abstract
OBJECTIVES Previous studies have indicated a progressive internal bacterial colonization of implants and possible implications for peri-implant bone loss. The aim of this study was to evaluate a decontamination protocol, two disinfectants, and a sealant for their ability to prevent such a colonization. MATERIALS AND METHODS Bacterial samples were harvested from the peri-implant sulcus (external) and following abutment removal from the implant cavity (internal) during routine supportive peri-implant care in 30 edentulous patients 2 years after they had obtained two implants. In a split-mouth design, implants were randomly assigned to receive either internal decontamination alone (10% H2 O2 , brush) or additional placement of either sealant (GS), disinfectant agent (CHX-varnish) or disinfectant gel (1% CHX-gel), in the internal cavity before remounting of abutment/suprastructure. Twelve months later, internal and external sampling was repeated. Total bacterial counts (TBCs) were determined using real-time PCR in a total of 240 samples (eight per patient). RESULTS Total bacterial counts in the internal cavity significantly reduced overall treatment modalities 1 year after the treatments (4.0 [2.3-6.9]-fold reduction; p = .000). No significant differences between the four treatment types were found (p = .348). Comparison of internal and external sampling points revealed significant correlation (R2 = .366; p = .000) with systematically higher TBC counts in external samples. CONCLUSIONS Within the limitations of the present study, it can be concluded that the use of disinfectant agents or a sealant did not show an additional benefit in the prevention of internal bacterial colonization of implants compared to a decontamination protocol alone.
Collapse
Affiliation(s)
- Pia-Merete Jervøe-Storm
- Department of Periodontology, Operative and Preventive Dentistry, University Hospital Bonn, Bonn, Germany
| | - Søren Jepsen
- Department of Periodontology, Operative and Preventive Dentistry, University Hospital Bonn, Bonn, Germany
| | - Michael Marder
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University Hospital Bonn, Bonn, Germany
| | - Dominik Kraus
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University Hospital Bonn, Bonn, Germany
| | - Milan Stoilov
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University Hospital Bonn, Bonn, Germany
| | - Norbert Enkling
- Department of Prosthodontics, Preclinical Education and Dental Material Science, University Hospital Bonn, Bonn, Germany
- Department of Reconstructive Dentistry & Gerodontology, University of Bern, Bern, Switzerland
| |
Collapse
|
12
|
Camps-Font O, Rubianes-Porta L, Valmaseda-Castellón E, Jung RE, Gay-Escoda C, Figueiredo R. Comparison of external, internal flat-to-flat, and conical implant abutment connections for implant-supported prostheses: A systematic review and network meta-analysis of randomized clinical trials. J Prosthet Dent 2023; 130:327-340. [PMID: 34776267 DOI: 10.1016/j.prosdent.2021.09.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2020] [Revised: 09/24/2021] [Accepted: 09/27/2021] [Indexed: 01/19/2023]
Abstract
STATEMENT OF PROBLEM The implant abutment connection interface has been considered one of the major factors affecting the outcome of implant therapy. However, drawbacks of traditional meta-analyses are the inability to compare more than 2 treatments at a time, which complicates the decision-making process for dental clinicians, and the lack of a network meta-analysis. PURPOSE The purpose of this network meta-analysis was to assess whether the implant abutment connection influences the outcome of implant-supported prostheses. MATERIAL AND METHODS An electronic search was undertaken to identify all randomized clinical trials comparing the effect of at least 2 different implant abutment connection designs published from 2009 up to May 2020. Outcome variables were implant survival rate, peri-implant marginal bone loss, and biologic and prosthetic complication rates at 12 months after prosthetic loading. Relevant information was extracted, and quality and risk of bias assessed. Pairwise meta-analyses and network meta-analyses based on a multivariate random-effects meta-regression were performed to assess the comparisons (α=.05 for all analyses). RESULTS For peri-implant marginal bone loss and prosthetic complications, conical interfaces were determined to be the most effective, with significant differences when compared with external hexagonal connections (P=.011 and P=.038, respectively). No significant differences were found among the implant abutment connections in terms of survival and biologic complications (P>.05 in all direct, indirect, and mixed comparisons). CONCLUSIONS After 1 year of loading, conical connections showed lower marginal bone loss and fewer prosthetic complications than external hexagonal connections. However, the implant abutment connection design had no influence on the implant survival and biologic complication rates.
Collapse
Affiliation(s)
- Octavi Camps-Font
- Associate Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain.
| | - Laura Rubianes-Porta
- Graduate student, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Eduard Valmaseda-Castellón
- Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Ronald E Jung
- Head of the Division of Implantology and Vice Chairman of the Center of Dental Medicine of the University of Zürich, Clinic for Fixed and Removable Prosthodontics and Dental Material Science, Zürich, Switzerland
| | - Cosme Gay-Escoda
- Chairman of Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| | - Rui Figueiredo
- Professor, Division of Oral Surgery and Implantology, Faculty of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain
| |
Collapse
|
13
|
Sherigar SR, Feine JS, Cooper LF, Stanford CM, Barwacz CA, McGuire M, Abi Nader S, de Souza RF. Can patients detect peri‑implant mucosal inflammation? Results from a multicentre randomized trial. J Dent 2023; 135:104592. [PMID: 37330036 DOI: 10.1016/j.jdent.2023.104592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 05/31/2023] [Accepted: 06/14/2023] [Indexed: 06/19/2023] Open
Abstract
PURPOSE The objective of this study was to compare patient-reported outcomes (PROs) of peri‑implant soft tissue inflammation and aesthetics around single-tooth implants in the anterior maxillary region with three different implant-abutment interface designs. METHODS Participants were randomized to one of three different types of implant-abutment interface designs [Conical (CI), flat-to-flat (FI), and Platform Switched (PS)]. Implants and provisional crowns with prefabricated titanium abutments were placed 5 months following extraction and/or ridge augmentation. Permanent ceramic crowns with zirconia abutments were placed after 12 weeks. To assess PROs, appearance and inflammation questionnaires were completed from provisional crown placement to the 3-year follow-up. RESULTS Tooth appearance at the 3-year follow-up revealed a difference amongst CI, FI and PS implants (p=0.049; Kruskal-Wallis test). PS was rated better than FI (p=0.047) at 1 year for appearance of soft-tissue and satisfaction with colour. There were no differences for self-consciousness, smile and pain/discomfort while eating/hard food items. CONCLUSIONS Although participants tended to rate the health of mucosa around PS implants as slighty better than the other two implant systems, the differences were minimal and inconsistent. Thus, patient satisfaction in terms self-perceived gingival health and esthetics was high for all 3 systems tested, suggesting that patients are unable to detect mucosal inflammation. CLINICAL SIGNIFICANCE Patients find it difficult to perceive mucosal inflammation; hence, it is recommended that patients attend implant follow-up visits, even if they do not perceive inflammation. The study suggests that there is a relationship between the PROs and the clinical outcomes of tested implants.
Collapse
Affiliation(s)
- Shwetha R Sherigar
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640, University St., # M/65A, Montreal, Quebec H3A2B2, Canada
| | - Jocelyne S Feine
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640, University St., # M/65A, Montreal, Quebec H3A2B2, Canada
| | - Lyndon F Cooper
- Oral Biology Dept, University of Illinois at Chicago, College of Dentistry, Chicago, IL, USA
| | - Clark M Stanford
- Edwin B. Green Endowed Chair. College of Dentistry, University of Iowa, Iowa City, IA, USA
| | - Christopher A Barwacz
- Department of Family Dentistry, The University of Iowa College of Dentistry, Iowa City, IA, USA
| | | | - Samer Abi Nader
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640, University St., # M/65A, Montreal, Quebec H3A2B2, Canada
| | - Raphael F de Souza
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, 3640, University St., # M/65A, Montreal, Quebec H3A2B2, Canada.
| |
Collapse
|
14
|
Kowalski J, Puszkarz AK, Radwanski M, Sokolowski J, Cichomski M, Bourgi R, Hardan L, Sauro S, Lukomska-Szymanska M. Micro-CT Evaluation of Microgaps at Implant-Abutment Connection. MATERIALS (BASEL, SWITZERLAND) 2023; 16:4491. [PMID: 37374674 DOI: 10.3390/ma16124491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 06/10/2023] [Accepted: 06/17/2023] [Indexed: 06/29/2023]
Abstract
The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 µm for Astra and from 0.1 to 4.9 µm for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.
Collapse
Affiliation(s)
- Jakub Kowalski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | - Adam K Puszkarz
- Faculty of Material Technologies and Textile Design, Institute of Material Science of Textiles and Polymer Composites, Lodz University of Technology, 116 Zeromskiego Street, 90-924 Lodz, Poland
| | - Mateusz Radwanski
- Department of Endodontics, Medical University of Lodz, 92-213 Lodz, Poland
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 92-213 Lodz, Poland
| | - Michal Cichomski
- Department of Material Technology and Chemistry, Faculty of Chemistry, University of Lodz, Pomorska 163, 90-236 Lodz, Poland
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Salvatore Sauro
- Dental Biomaterials and Minimally Invasive Dentistry, Departamento de Odontología, Facultad de Cienciasde la Salud, Universidad CEU-Cardenal Herrera, C/Del Pozo ss/n, Alfara del Patriarca, 46115 Valencia, Spain
- Department of Therapeutic Dentistry, I. M. Sechenov First Moscow State Medical University, 119146 Moscow, Russia
| | | |
Collapse
|
15
|
Son M, Song Y, Yu Y, Kim SY, Huh JB, Bae EB, Cho WT, Na HS, Chung J. The oral microbiome of implant-abutment screw holes compared with the peri-implant sulcus and natural supragingival plaque in healthy individuals. J Periodontal Implant Sci 2023; 53:53.e20. [PMID: 37336525 DOI: 10.5051/jpis.2300100005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/14/2023] [Accepted: 04/27/2023] [Indexed: 06/21/2023] Open
Abstract
PURPOSE An implant-supported prosthesis consists of an implant fixture, an abutment, an internal screw that connects the abutment to the implant fixture, and the upper prosthesis. Numerous studies have investigated the microorganisms present on the implant surface, surrounding tissues, and the subgingival microflora associated with peri-implantitis. However, there is limited information regarding the microbiome within the internal screw space. In this study, microbial samples were collected from the supragingival surfaces of natural teeth, the peri-implant sulcus, and the implant-abutment screw hole, in order to characterize the microbiome of the internal screw space in healthy subjects. METHODS Samples were obtained from the supragingival region of natural teeth, the peri-implant sulcus, and the implant screw hole in 20 healthy subjects. DNA was extracted, and the V3-V4 region of the 16S ribosomal RNA was sequenced for microbiome analysis. Alpha diversity, beta diversity, linear discriminant analysis effect size (LEfSe), and network analysis were employed to compare the characteristics of the microbiomes. RESULTS We observed significant differences in beta diversity among the samples. Upon analyzing the significant taxa using LEfSe, the microbial composition of the implant-abutment screw hole's microbiome was found to be similar to that of the other sampling sites' microbiomes. Moreover, the microbiome network analysis revealed a unique network complexity in samples obtained from the implant screw hole compared to those from the other sampling sites. CONCLUSIONS The bacterial composition of the biofilm collected from the implant-abutment screw hole exhibited significant differences compared to the supra-structure of the implant. Therefore, long-term monitoring and management of not only the peri-implant tissue but also the implant screw are necessary.
Collapse
Affiliation(s)
- MinKee Son
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Yuri Song
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
| | - Yeuni Yu
- Interdisciplinary Program of Genomic Science, Pusan National University, Yangsan, Korea
- Department of Biomedical Informatics, School of Medicine, Pusan National University, Busan, Korea
| | - Si Yeong Kim
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jung-Bo Huh
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Eun-Bin Bae
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Won-Tak Cho
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Hee Sam Na
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jin Chung
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea.
| |
Collapse
|
16
|
Khamis MM, Zakaria NH, Farrag KM, Abolgheit S. Evaluation of the dislodgement force of splinted restorations with engaging conical abutments over multiple nonparallel implants (in-vitro study). BMC Oral Health 2023; 23:300. [PMID: 37198623 DOI: 10.1186/s12903-023-02958-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Accepted: 04/10/2023] [Indexed: 05/19/2023] Open
Abstract
BACKGROUND Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments. METHODS Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0-10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman's rank correlation coefficient. RESULTS The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman's rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. CONCLUSIONS Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.
Collapse
Affiliation(s)
- Mohamed Moataz Khamis
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Niveen Hazem Zakaria
- Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Khaled Mohamed Farrag
- Division of Fixed Prosthodontics, Conservative Dentistry Department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Salma Abolgheit
- Department of Dental Biomaterials, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
17
|
Fuda S, Martins BGDS, Castro FCD, Heboyan A, Gehrke SA, Fernandes JCH, Mello-Moura ACV, Fernandes GVO. Marginal Bone Level and Clinical Parameter Analysis Comparing External Hexagon and Morse Taper Implants: A Systematic Review and Meta-Analysis. Diagnostics (Basel) 2023; 13:diagnostics13091587. [PMID: 37174979 PMCID: PMC10178059 DOI: 10.3390/diagnostics13091587] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 04/18/2023] [Accepted: 04/25/2023] [Indexed: 05/15/2023] Open
Abstract
The goal of this systematic review was to verify the marginal bone loss (MBL) and other clinical parameters comparing external hexagon (EH) and Morse taper (MT) implants when they were evaluated within the same study. The focused question was, "For patients (P) treated with external connection (I) or Morse taper (C) dental implants, were there differences in the marginal bone crest maintenance after at least three months in occlusal function (O)"? As for the inclusion criteria that were considered, they included clinical studies in English that compared the MBL in implants with EH and MT, with follow-up of at least three months, that were published between 2011 and 2022; as for the exclusion criteria, they included publications investigating only one type of connection that analyzed other variables and did not report results for the MBL, reports based on questionnaires, interviews, and case reports/series, systematic reviews, or studies involving patients with a significant health problem (ASA Physical Status 3 and above). The PubMed/MEDLINE, Embase, and Web of Science databases were screened, and all of the data obtained were registered in a spreadsheet (Excel®). The Jadad scale was used to assess the quality of the studies. A total of 110 articles were initially identified; 11 were considered for full-text reading. Then, six articles (four RCTs and two prospective studies) met the eligibility criteria and were included in this study. A total of 185 patients (mean age of 59.71) were observed, and the follow-up ranged from 3 months to 36 months. A total of 541 implants were registered (267 EH and 274 MT). The survival rate ranged between 96% and 100% (the average was 97.82%). The MBL was compared among all periods studied; therefore, the common assessment period was the 12-month follow-up, presenting greater MBL for EH than for MT (p < 0.001). A mean MBL of 0.60 mm (95% CI 0.43-0.78) was found after the same period. BoP was reported in 5 studies and plaque index was reported in 4 (2 with more than 30%). Deep PD was observed in three studies. High heterogeneity was observed (I2 = 85.06%). Thus, within the limitation of this review, it was possible to conclude that there is higher bone loss in EH than in MT implants when evaluating and comparing this variable within the same study. However, the results must be carefully interpreted because of this review's limited number of clinical studies, the short assessment period, and the high heterogeneity found.
Collapse
Affiliation(s)
- Samuele Fuda
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | | | | | - Artak Heboyan
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, Yerevan 0025, Armenia
| | - Sergio Alexandre Gehrke
- Department of Research, Bioface/PgO/UCAM, Calle Cuareim 1483, Montevideo 11100, Uruguay
- Instituto de Bioingenieria, Universidad Miguel Hernández, 03202 Elche, Spain
- Department of Biotechnology, Universidad Católica de Murcia (UCAM), 30107 Murcia, Spain
| | | | - Anna Carolina Volpi Mello-Moura
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Gustavo Vicentis Oliveira Fernandes
- Periodontics and Oral Medicine Department, University of Michigan School of Dentistry, Ann Arbor, MI 48109, USA
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| |
Collapse
|
18
|
Maceiras L, Liñares A, Nóvoa L, Batalla P, Mareque S, Pérez J, Blanco J. Marginal changes at bone-level implants supporting fixed screw-retained partial implant prostheses with or without intermediate standardised abutments: 1-year results of a randomised controlled clinical trial. Clin Oral Implants Res 2023; 34:263-274. [PMID: 36708068 DOI: 10.1111/clr.14039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 11/09/2022] [Accepted: 01/06/2023] [Indexed: 01/29/2023]
Abstract
OBJECTIVE To compare marginal changes at bone-level implants restored with screw-retained implant prosthesis with or without intermediate standardised abutments, after 1 year of follow-up. MATERIALS AND METHODS Thirty-six partially edentulous patients received 72 implants. Each patient received 2 implants and a 2- to 4-unit screw-retained implant-prosthesis. The test group received implants consisting of a screw-retained prosthesis connected directly to the implant shoulder, while the prostheses in the control group were connected through a 3-mm standardised intermediate abutment. Clinical and radiological data were recorded at baseline and at 3, 6 and 12 months in follow-up visits. RESULTS At 12 months, the marginal bone loss was 0.17 ± 0.24 mm for the test group (19 patients) and 0.09 ± 0.15 mm for the control group (17 patients), with no statistically significant differences (p > .05). The mean probing pocket depth was 2.96 mm ± 0.46 for the test group and 2.86 ± 0.62 mm for the control group. The test and control groups showed bleeding on probing levels of 18.86 ± 14.12% and 13.73 ± 17.66%, respectively. All patients scored below 25% on the plaque index levels. CONCLUSIONS Restoration of bone-level implants with fixed screw-retained partial prostheses with or without intermediate abutments presented similar radiographic and clinical outcomes after 1 year.
Collapse
Affiliation(s)
- Lucía Maceiras
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Antonio Liñares
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.,Medical-Surgical Odontology (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Lourdes Nóvoa
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Pilar Batalla
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Santiago Mareque
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | | | - Juan Blanco
- Periodontology Unit, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain.,Medical-Surgical Odontology (OMEQUI) Research Group, Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| |
Collapse
|
19
|
Analysis of the physical, mechanical and morphological properties of polyethylene terephthalate polymer in the manufacture of dentistry prosthetic components. Polym Bull (Berl) 2022. [DOI: 10.1007/s00289-022-04621-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
20
|
Clinical Outcomes of Dental Implants with Two Different Internal Connection Configurations—A RCT. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4040046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: The aim of the present study was to highlight clinical and radiographical differences among implants sharing the same macro-geometry but with two different prosthodontic connections. Methods: Patients requiring at least 2 implants in the posterior area of the jaw were randomly divided into two groups (Conical (CS) and Internal Hexagonal (IH) connection). At implant surgery (T0), insertion torque, implant stability quotient (ISQ values recorded by resonance frequency analysis, RFA), and soft tissue thickness (STH) were assessed. A 1-abutment/1-time protocol was applied, and the prosthesis was realized following a fully digital workflow. At the 36-month follow-up periapical x-rays were taken. In order to statistically analyse differences among the two groups and the different variables, paired T-test was used. Linear regression analysis was conducted to analyze how marginal bone loss (MBL) was affected by other independent variables. A neural network created to predict the success (good or not good) of the implant itself was implemented. Results: 30 out of 33 patients (14 males, 16 females, mean age: 68.94 ± 13.01 years) (32 CS and 32 IH) were analyzed. No implants failed. Marginal bone loss at the 3-year time-point was 0.33 ± 0.34 mm and 0.43 ± 0.37 mm respectively for CS and IH with a significant difference between the two groups (p = 0.004). The presence of keratinized gingiva (p = 0.034) significantly influenced MBL. Conclusions: Both the implant connections investigated presented optimal clinical outcomes with minimal marginal bone loss; however, CS implants and implants with the presence of a greater width of keratinized tissue presented significantly lower MBL.
Collapse
|
21
|
Byun SH, Seo JH, Cho RY, Yi SM, Kim LK, Han HS, On SW, Kim WH, An HW, Yang BE. Finite Element Analysis of a New Non-Engaging Abutment System for Three-Unit Implant-Supported Fixed Dental Prostheses. Bioengineering (Basel) 2022; 9:483. [PMID: 36290451 PMCID: PMC9598935 DOI: 10.3390/bioengineering9100483] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 09/09/2022] [Accepted: 09/15/2022] [Indexed: 07/30/2023] Open
Abstract
(1) Background: The stability of implants plays a significant role in the success of osseointegration. The stability of the connection between the fixture and the abutment is one of the critical factors affecting osseointegration. When restoring multiple, non-parallel, and splinted implants, achieving a passive fit can be complicated and challenging. A new EZ post non-engaging abutment system of the BlueDiamond® (BD) implant allows a wide connection angle while achieving a passive prosthesis fit. This study aimed to confirm the new abutment system's clinical applicability by evaluating its biomechanical characteristics using finite element analysis (FEA). (2) Methods: The implant-supported fixed three-unit dental prostheses model was reproduced for two groups of AnyOne® (AO) and BD implants using FEA. The loading conditions were a preload of 200 N in the first step and loads of 100 N (axial), 100 N (15°), or 30 N (45°) in the second step. (3) Results: The peak Von Mises stress (PVMS) value of the fixture in the BD group was more than twice that in the AO group. In contrast, the PVMS values of the abutment and abutment screws were lower in the BD group than in the AO group. The AO group revealed higher maximal principal stress (MPS) values than that of the BD group in the cortical bone, cancellous bone, and crown. The average stress of the outer surface of the abutment was lower in the AO group than in the BD group. The stress distribution for the inner surface of the fixture confirmed that the BD group displayed a lower stress distribution than the AO group under axial and 15° loads; however, the average stress was 1.5 times higher at the 45° load. The stress values of the entire surface where the cortical and cancellous bone were in contact with the fixture were measured. The AO group showed a higher stress value than the BD group in both cortical and cancellous bone. (4) Conclusions: In the AO group, the PVMS value of the fixture and the stress distribution at the contact surface between the fixture and the abutment were lower than those of the BD group, suggesting that the stability of the fixture would be high. However, due to the high stress in the fastening area of the abutment and abutment screw, the risk of abutment fracture in the AO group is higher than that of the BD group. Therefore, the new EZ post non-engaging abutment of the BD implant can be used without any problems in clinics, similar to the non-engaging abutment of the AO implant, which has been widely used in clinical practice.
Collapse
Affiliation(s)
- Soo-Hwan Byun
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
| | - Joung-Hwa Seo
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
| | - Ran-Yeong Cho
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
| | - Sang-Min Yi
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
| | - Lee-Kyong Kim
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
| | - Hyun-Sook Han
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Department of Prosthodontics, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
| | - Sung-Woon On
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Division of Oral and Maxillofacial Surgery, Department of Dentistry, Hallym University Dongtan Sacred Heart Hospital, Hwaseong 18450, Korea
| | - Won-Hyeon Kim
- Dental Life Science Research Institute/Innovative Research & Support Center for Dental Science, Seoul National University Dental Hospital, Seoul 03080, Korea
| | - Hyun-Wook An
- Research and Development Center, MegaGen Implant Co., Ltd., Daegu 42921, Korea
| | - Byoung-Eun Yang
- Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang 14068, Korea
- Graduate School of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
- Institute of Clinical Dentistry, Hallym University, Chuncheon 24252, Korea
| |
Collapse
|
22
|
Kim S, Lee JW, Kim JH, Truong VM, Park YS. Assessing Microleakage at 2 Different Implant-Healing Abutment Interfaces. Int Dent J 2022; 73:370-376. [PMID: 36075760 DOI: 10.1016/j.identj.2022.07.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/24/2022] [Accepted: 07/27/2022] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES This study aimed to evaluate implants from different manufacturers and determine whether implant-healing abutment interface has a significant impact on implant seal. METHODS An air-injection pressure measurement test was performed on implants with either line-contact (modified TSIII [TSM] and Bone Level Tapered [BLT]) or partial face-contact (BlueDiamond [BD], SuperLine [SL], ISII, and UFII) interface design from 6 different manufacturers. Forty implants per implant type were analysed. Pressure data were evaluated with Kruskal-Wallis test and Dunn's post hoc analysis (statistical significance was set at P < .05). RESULTS BLT implants leaked when the mean pressure was increased to 199.9 kPa. The following implants showed mean leakage pressures of 182.9 (TSM), 157.4 (BD), 112.9 (SL), 101.8 (ISII), and 30.6 (UFII). There was a significant difference between line-contact and partial face-contact implants (P < .001). CONCLUSIONS The implant interface design has a significant impact on implant microbial leakage. Implants with a line-contact interface exhibited a higher resistance to leakage than those with partial face-contact.
Collapse
Affiliation(s)
- Soyeon Kim
- Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Joo Won Lee
- Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Jae-Heon Kim
- Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Van Mai Truong
- Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Young-Seok Park
- Department of Oral Anatomy and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea; Center for Future Dentistry, School of Dentistry, Seoul National University, Seoul, Republic of Korea.
| |
Collapse
|
23
|
Full-Arch Rehabilitation Using Trans-Mucosal Tissue-Level Implants with and without Implant-Abutment Units: A Case Report. Dent J (Basel) 2022; 10:dj10070116. [PMID: 35877390 PMCID: PMC9320847 DOI: 10.3390/dj10070116] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Revised: 06/13/2022] [Accepted: 06/22/2022] [Indexed: 01/27/2023] Open
Abstract
Recently, tissue-level implants with a convergent collar have been introduced. While different studies have investigated the outcomes of this implant design in the rehabilitation of single teeth, its use in full-arch rehabilitation has yet to be investigated. The present case report describes the clinical outcomes of a full-arch immediate loading rehabilitation using tissue-level implants, with and without using implant-abutment units, with 2 years of follow-up. A female patient with mandibular terminal dentition and a high level of bone resorption (distal areas with a few millimeters of residual bone in the vertical dimension and both distal and anterior areas with narrow crestal bone in the horizontal dimension) was seen at the C.I.R Dental School, Turin, Italy. The patient was seeking to be rehabilitated with fixed prosthodontics, and she was found eligible for an immediate loading implant full-arch rehabilitation. Four implants were inserted in the same appointment. The two anterior implants were inserted straight and connected directly to the prosthesis (no abutments); the two distal implants were tilted in order to avoid the alveolar nerve and connected to two 30° angulated abutments. Two years post-implant placement, all of the implants were successfully integrated, resulting in an implant survival rate of 100%. The peri-implant soft tissues were stable at all the implant sites. No differences were highlighted between those implants with and without abutments. Within the limitations of the present clinical report, implant full-arch rehabilitations with tissue-level implants both with and without implant-abutment units showed optimal outcomes after two years of follow-up. Further research is encouraged to confirm whether this implant design may be a valid alternative to traditional implants in this type of rehabilitation, with or without implant-abutment units.
Collapse
|
24
|
Kim YM, Lee JB, Um HS, Chang BS, Lee JK. Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants. J Periodontal Implant Sci 2022; 52:496-508. [PMID: 36468468 PMCID: PMC9807847 DOI: 10.5051/jpis.2200960048] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/02/2022] [Accepted: 05/17/2022] [Indexed: 01/07/2023] Open
Abstract
PURPOSE This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. METHODS Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. RESULTS The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. CONCLUSIONS There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.
Collapse
Affiliation(s)
- Young-Min Kim
- Department of Periodontology and Research Institute of Oral Sciences, Gangneung-Wonju National University College of Dentistry, Gangneung, Korea
| | - Jong-Bin Lee
- Department of Periodontology and Research Institute of Oral Sciences, Gangneung-Wonju National University College of Dentistry, Gangneung, Korea
| | - Heung-Sik Um
- Department of Periodontology and Research Institute of Oral Sciences, Gangneung-Wonju National University College of Dentistry, Gangneung, Korea
| | - Beom-Seok Chang
- Department of Periodontology and Research Institute of Oral Sciences, Gangneung-Wonju National University College of Dentistry, Gangneung, Korea
| | - Jae-Kwan Lee
- Department of Periodontology and Research Institute of Oral Sciences, Gangneung-Wonju National University College of Dentistry, Gangneung, Korea
| |
Collapse
|
25
|
Pokrowiecki R, Szałaj U, Fudala D, Zaręba T, Wojnarowicz J, Łojkowski W, Tyski S, Dowgierd K, Mielczarek A. Dental Implant Healing Screws as Temporary Oral Drug Delivery Systems for Decrease of Infections in the Area of the Head and Neck. Int J Nanomedicine 2022; 17:1679-1693. [PMID: 35440868 PMCID: PMC9013419 DOI: 10.2147/ijn.s333720] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2021] [Accepted: 01/31/2022] [Indexed: 12/13/2022] Open
Abstract
Background Periimplantitis is continuously one of major threats for the uneventful functioning of dental implants. Current approaches of drug delivery systems are being more commonly implemented into oral- and maxillofacial biomaterials in order to decrease the risk of implant failure due to bacterial infection. Silver nanoparticles and their compounds have been proven in eradicating oral bacteria responsible for peri-implant infections. Nevertheless, their evaluation as coating for implant abutments has not been extensively evaluated so far. This article describes a novel coating consisting of zinc oxide (ZnO) and silver (Ag) nanoparticles (NPs). This coating was used to modify healing abutments that could be used as drug delivery systems in oral implantology. Materials and Method Nanoparticles with a ZnO + 0.1% Ag composition were produced by microwave solvothermal synthesis and then incorporated into the surface of titanium healing abutments by high-power ultrasonic deposition. Surface morphology, roughness, wettability were evaluated. Ability of biofilm formation inhibition was tested against S. mutans, S. oralis, S. aureus and E. coli. Results ZnO+0.1%Ag NPs were sufficiently deposed on the surface of the abutments creating nanostructured coating which increased surface roughness and decreased wettability. Modified abutments significantly decreased bacterial biofilm formation. Bacteria present in SEM studies were unlikely to settle and replicate on the experimental abutments as their cells were rounded, insufficiently spread on the surface and covered with released NPs. Conclusion Experimental nanostructured abutments were easily manufactured by high-power ultrasonic deposition and provided significant antibacterial properties. Such biomaterials could be used as temporary drug delivery abutments for prevention and treatment of intra- and extraoral peri-implant infections in the area of the head and neck.
Collapse
Affiliation(s)
- Rafał Pokrowiecki
- Department of Cranio- Maxillofacial Surgery, Oral Surgery and Implantology, Medical University of Warsaw, Warsaw, Poland
- Head and Neck Surgery Department—Maxillofacial Surgery Department, Craniofacial Center, Regional Specialized Children’s Hospital, Olsztyn, 10-561, Poland
| | - Urszula Szałaj
- Institute of High Pressure Physics, Polish Academy of Sciences, Warsaw, Poland
- Faculty of Materials Engineering, Warsaw University of Technology, Warsaw, Poland
| | - Damian Fudala
- Institute of High Pressure Physics, Polish Academy of Sciences, Warsaw, Poland
| | - Tomasz Zaręba
- Department of Antibiotics and Microbiology, National Medicines Institute, Warsaw, Poland
| | - Jacek Wojnarowicz
- Institute of High Pressure Physics, Polish Academy of Sciences, Warsaw, Poland
| | - Witold Łojkowski
- Institute of High Pressure Physics, Polish Academy of Sciences, Warsaw, Poland
| | - Stefan Tyski
- Department of Antibiotics and Microbiology, National Medicines Institute, Warsaw, Poland
| | - Krzysztof Dowgierd
- Head and Neck Surgery Clinic for Children and Young Adults, Department of Clinical Pediatrics, University of Warmia and Mazury, Olsztyn, 10-719, Poland
| | - Agnieszka Mielczarek
- Department of Conservative Dentistry, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
26
|
Galindo-Moreno P, Concha-Jeronimo A, Lopez-Chaichio L, Rodriguez-Alvarez R, Sanchez-Fernandez E, Padial-Molina M. Marginal Bone Loss around Implants with Internal Hexagonal and Internal Conical Connections: A 12-Month Randomized Pilot Study. J Clin Med 2021; 10:jcm10225427. [PMID: 34830709 PMCID: PMC8621760 DOI: 10.3390/jcm10225427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Revised: 11/12/2021] [Accepted: 11/18/2021] [Indexed: 02/07/2023] Open
Abstract
The aim of this study was to analyze the differences in terms of the marginal bone level (MBL) around implants with either an internal conical or an internal hexagonal implant–prosthesis connection. A randomized clinical trial included patients in need of a single implant-supported restoration. The implant–prosthesis connection was either internal conical or internal hexagonal while maintaining the same type of implant macro- and microarchitecture. Clinical and radiographical variables were registered up to 12 months of follow-up, including MBL. A total of 30 patients were included in the study. The main outcome variable, MBL 12 months after prosthesis delivery, was statistically different in both groups: −0.25 (0.12) vs. −0.70 (0.43) (conical vs. hexagonal; p = 0.033). Differences were also observed at the 3- and 6-month follow-up visits as well as for the MBL change from prosthesis delivery to the 12-month follow-up (−0.15 (0.13) vs. −0.56 (0.44); conical vs. hexagonal; p = 0.023). Correlations between MBL around the implants and radiographic measurements on the adjacent teeth, buccal bone to implant, tissue thickness or keratinized tissue were not significant neither globally nor when analyzed independently by group. In view of such results, it can be concluded that single-unit restorations with internal hexagonal-connection implants induce higher marginal bone loss after 12 months of follow-up from prosthesis delivery than internal conical-connection implants.
Collapse
Affiliation(s)
- Pablo Galindo-Moreno
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- Correspondence:
| | - Ada Concha-Jeronimo
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Lucia Lopez-Chaichio
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Roque Rodriguez-Alvarez
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| | - Elena Sanchez-Fernandez
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
| | - Miguel Padial-Molina
- Department of Oral Surgery and Implant Dentistry, School of Dentistry, University of Granada, 18071 Granada, Spain; (E.S.-F.); (M.P.-M.)
- Research Group in Oral Biology and Regeneration (CTS-1028), Junta de Andalucia, 18071 Granada, Spain;
- PhD Program in Clinical Medicine and Public Health, University of Granada, 18016 Granada, Spain; (A.C.-J.); (L.L.-C.)
| |
Collapse
|
27
|
Passarelli PC, Netti A, Lopez MA, Giaquinto EF, De Rosa G, Aureli G, Bodnarenko A, Papi P, Starzyńska A, Pompa G, D’Addona A. Local/Topical Antibiotics for Peri-Implantitis Treatment: A Systematic Review. Antibiotics (Basel) 2021; 10:antibiotics10111298. [PMID: 34827236 PMCID: PMC8615130 DOI: 10.3390/antibiotics10111298] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Revised: 10/13/2021] [Accepted: 10/22/2021] [Indexed: 11/16/2022] Open
Abstract
Most studies indicate that the mechanical removal of the bacterial biofilm from the implant surface is the central goal of peri-implantitis therapy. However, controversial results in the treatment of peri-implantitis have led to the consideration of additional strategies that include surgical approaches and chemical adjuvants. Local/topical antibiotics, such as minocycline, azithromycin, tetracycline, amoxicillin, doxycycline, and metronidazole, may improve the efficacy of the definitive treatment of the disease, but the lack of conclusive findings prevents their use in clinical practice. This systematic review aimed to evaluate the effect of local/topical antibiotics for peri-implantitis treatment. Randomised controlled studies (RCT) on patients with peri-implantitis and comparing the efficacy of local/topical antibiotics vs. placebo or mechanical debridement were included. A systematic search strategy was carried out using three registered databases (PubMed, Web of Science, and Scopus). RoB2 was used to assess risk of bias. Five RCTs were identified (n = 250 patients and 333 implants). Contrast results emerged among the included studies, and a high heterogeneity level was observed. Risk of bias revealed some concerns for three studies out of five, while one study was judged at high risk. Only one study analysed the limitations of its findings. Overall, local antibiotic use can be considered a valid approach in the treatment of peri-implantitis. Therefore, future long-term clinical trials with standardised protocols and antibiotics with similar biological activity profiles should be tested to achieve a valid and definitive conclusion.
Collapse
Affiliation(s)
- Pier Carmine Passarelli
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
| | - Andrea Netti
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
- Correspondence: ; Tel./Fax: +39-06-3015-4079
| | | | - Eleonora Favetti Giaquinto
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
| | - Giuseppe De Rosa
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
| | - Gianmarco Aureli
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
| | - Alina Bodnarenko
- Department of Oral Surgery, Medical University of Gdańsk, 7 Dębinki Street, 80-211 Gdańsk, Poland; (A.B.); (A.S.)
| | - Piero Papi
- Department of Oral and Maxillofacial Sciences, Policlinico Umberto I, “Sapienza” University of Rome, 00161 Rome, Italy; (P.P.); (G.P.)
| | - Anna Starzyńska
- Department of Oral Surgery, Medical University of Gdańsk, 7 Dębinki Street, 80-211 Gdańsk, Poland; (A.B.); (A.S.)
| | - Giorgio Pompa
- Department of Oral and Maxillofacial Sciences, Policlinico Umberto I, “Sapienza” University of Rome, 00161 Rome, Italy; (P.P.); (G.P.)
| | - Antonio D’Addona
- Department of Head and Neck and Sensory Organs, Division of Oral Surgery and Implantology, Institute of Clinical Dentistry, Gemelli Foundation for the University Policlinic, Catholic University of the “Sacred Heart”, 00168 Rome, Italy; (P.C.P.); (E.F.G.); (G.D.R.); (G.A.); (A.D.)
| |
Collapse
|
28
|
Seloto CB, Strazzi-Sahyon HB, Dos Santos PH, Assunção WG. Performance of different abutment/implant joints as a result of a sealing agent. J Prosthodont Res 2021; 65:489-494. [PMID: 34470982 DOI: 10.2186/jpr.jpr_d_20_00025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose This in vitro study aimed to evaluate the effectiveness of a sealing agent in sealing the abutment/implant interface and the preload maintenance of retaining screws after mechanical cycling.Methods Six groups (n = 12) were evaluated according to the abutment/implant system (external-hexagon implant and UCLA abutments, EHU; Morse taper implant and UCLA abutments, MTU; and Morse taper implant and flexcone abutments, MTF) and the presence of an anaerobic gel sealing agent (control group, no sealing agent; experimental group, sealing agent). Toluidine blue (0.7 μL) was inserted into each implant and the abutments were attached to the implants using a digital torque wrench to evaluate the sealing of the abutment/implant interface. The specimens were tested through mechanical cycling (1 × 106 cycles, 2 Hz, and 130 N). Dye release from the abutment/implant interface was analyzed using a spectrophotometer, and the reverse torque values were obtained using a digital wrench. Reverse torque and dye release data were measured after mechanical cycling and analyzed using ANOVA and Tukey's test (α =.05).Results All experimental groups showed higher reverse torque values than the control groups (P <.05). In general, the MTU and MTF experimental groups, as well as the MTF control group, showed no significant dye release at different periods (P >.05).Conclusions The use of a sealing agent improved the preload maintenance of screw-retained implant-supported prostheses. The sealing agent was effective in sealing the Morse taper connection.
Collapse
Affiliation(s)
- Camila Berbel Seloto
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, São Paulo, Brazil
| | - Henrico Badaoui Strazzi-Sahyon
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, São Paulo, Brazil
| | - Paulo Henrique Dos Santos
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, São Paulo, Brazil
| | - Wirley Gonçalves Assunção
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University, São Paulo, Brazil
| |
Collapse
|
29
|
Mukhopadhyay P, Khalikar A, Wankhade S, Deogade S. The Microbial Neck: A Biological Review of the Various Implant–Abutment Connections. JOURNAL OF ADVANCED ORAL RESEARCH 2021. [DOI: 10.1177/23202068211041785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Aim: This study reviews the importance of selecting implant systems with connection designs that ensure better long-term prognosis of the prosthesis, thus placed. Materials and Methods: An electronic search on the PubMed database was done using MeSH keywords (“dental implant OR abutment OR connection AND microleakage OR bone loss”) to review English language articles published since the year 2011, which compared the crestal bone levels and microleakage around various implant–abutment connection designs (external hex, internal hex, and Morse taper). The search screened for articles on human trials and in vitro studies to be included within the review. Results: Based on the inclusion and exclusion criteria applied to the preliminary search, a total of four articles were included in the review for evaluating the influence of connection type on peri-implant bone loss, while nine articles were included to study the influence on bacterial leakage across the implant–abutment interface. Conclusion: Based on the studies reviewed, the conical connection design proved to be the most biologically stable junctional geometry because of the better microbial seal and the lesser micromovement observed in these types of implants during functional loading. Moreover, this review even emphasizes the need for more longitudinal clinical trials to assess the microbial seal of these connection designs within the actual oral environment to evaluate long-term changes in the peri-implant tissues, and subsequently even factor the prognosis of the planned prosthetic intervention.
Collapse
Affiliation(s)
- Pronoy Mukhopadhyay
- Department of Prosthodontics, Government Dental College and Hospital, Nagpur, Maharashtra, India
| | - Arun Khalikar
- Department of Prosthodontics, Government Dental College and Hospital, Nagpur, Maharashtra, India
| | - Sattyam Wankhade
- Department of Prosthodontics, Government Dental College and Hospital, Nagpur, Maharashtra, India
| | - Suryakant Deogade
- Department of Prosthodontics, Government Dental College and Hospital, Nagpur, Maharashtra, India
| |
Collapse
|
30
|
Gehrke SA, Dedavid BA, Marín JMG, Canullo L. Behavior of implant and abutment sets of three different connections during the non-axial load application: An in vitro experimental study using a radiographic method. Biomed Mater Eng 2021; 33:101-112. [PMID: 34511480 DOI: 10.3233/bme-211221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND During the masticatory cycle, loads of different intensities and directions are received by the dental structures and/or implants, which can cause micromovements at the junction between the abutment and implant. OBJECTIVE The objective of this in vitro study was to evaluate the behavior of three different implant connections subjected to different load values using a digital radiography system. Additionally, the torque values for removing the abutment screws were also measured and compared. METHODS Ninety sets of implant and abutment (IA) were used, divided into three groups according to the type of connection (n = 30 per group): EH group, external hexagon type connection; IH group, internal hexagon connection; and, MT group, Morse taper connection. RESULTS MT group showed the better vertical misfit behavior at the three intensity of load applied, in comparison with EH and IH groups. In the analysis of torque maintenance (detorque test), MT group showed higher values of detorque when compared with the measured values of EH and IH groups (p < 0.001). CONCLUSIONS The IA sets of EH and IH groups showed a microgap in all levels of applied loads, unlike the MT group this event was not observed. In the detorque test, MT group increase in the torque values when compared to the initial torque applied, unlike EH and IH groups showed a decrease in the initially torque applied in all conditions tested. A positive correlation was detected between the misfit and detorque values.
Collapse
Affiliation(s)
- Sergio Alexandre Gehrke
- Department of Research, Biotecnos, Montevideo, Uruguay.,Department of Biotechnology, Universidad Católica de Murcia (UCAM), Murcia, Spain
| | - Berenice Anina Dedavid
- Department of Materials Engineering, Pontificia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil
| | | | | |
Collapse
|
31
|
Choudhary S, Verma N, Anand S, Sinha A, Shankar D. Comparative Evaluation of Changes in Microflora in Delayed and Immediate Implant Placement: An In vivo Study. J Pharm Bioallied Sci 2021; 13:S105-S108. [PMID: 34447054 PMCID: PMC8375859 DOI: 10.4103/jpbs.jpbs_572_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 09/26/2020] [Accepted: 10/09/2020] [Indexed: 11/27/2022] Open
Abstract
Aim: This study is aimed to compare and evaluate the changes in the microflora in immediate and delayed placed implants. Materials and Methods: In this study, the implant site sample was taken and assessed during different phases of treatment for delayed and immediate implants. They were looked for Streptococcus, Aggregatibacter actinomycetemcomitans, Prevotella intermedia, Porphyromonas gingivalis, and Fusobacterium nucleatum. Results: The results showed that Streptococci were found in a higher number in all the phases of the treatment. The presence of pathogenic organisms such as P. gingivalis and Fusobacterium, in considerable amounts, was seen in both the groups. Conclusion: Thus, we conclude that implant mode of placement, delayed or immediate placement does not alter the flora of the oral cavity. Organisms present remains the same in all the phase of the treatment. To prevent the disease, one must continuously monitor the implant, with the increasing age changes, the microflora is continually changing in the oral cavity. The periodontal health should be assessed before the placement of the implant, followed by follow-ups after a set period for a better prognosis.
Collapse
Affiliation(s)
| | - Neeraj Verma
- Department of Dentistry, Patna Medical and Hospital, Patna, Bihar, India
| | - Santosh Anand
- Department of Prosthodontics and Crown and Bridge, Patna Dental College and Hospital, Patna, Bihar, India
| | - Abhishek Sinha
- Department of Dentistry, Patna Medical College, Patna, Bihar, India
| | - Daya Shankar
- Department of Dentistry, Patna Medical College and Hospital, Patna, Bihar, India
| |
Collapse
|
32
|
Fernandes PF, Grenho L, Fernandes MH, Sampaio-Fernandes JC, Sousa Gomes P. Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent. Odontology 2021; 110:231-239. [PMID: 34448952 DOI: 10.1007/s10266-021-00652-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 08/21/2021] [Indexed: 11/26/2022]
Abstract
The present study aims to characterize, for the first time, the microgap and bacterial microleakage of a platform-switched implant system with hybrid connection, screwed at distinct torque values (manufacturer recommended torque-25 N cm-and a reduced torque-5 N cm-mimicking the long-term functional use), in the absence or presence of a silicon-based sealing agent. Microgap was determined through scanning electron microscopy and bacterial microleakage was evaluated in vitro, upon Enterococcus faecalis colonization of the system. The sealing efficacy was evaluated in the absence or presence of a commercially available silicon-based sealer. The cytotoxicity of the sealer was further addressed in vitro, with a fibroblastic cell line, in accordance with reference standards. A low microgap of the implant system was verified, regardless of the applied torque load-maximal values ranged around 0.25 and 1.25 µm, for 25 and 5 N cm torques, respectively. No bacterial microleakage was reported at 25 N cm, while at 5 N cm, leakage was verified on 38% of the samples. The application of a silicon-based sealer-with an adequate cytocompatible profile-was effective on preventing the bacterial microleakage on the assayed experimental setting. The assayed platform-switched implant system with hybrid connection presented a low interfacial misfit and an effective sealing capability at manufacturer recommended torque. Despite the increased microleakage at low torque conditions, the application of a cytocompatible silicon-based sealing agent restored the sealing effectiveness of the system. The use of a silicon-based sealing agent can assist on the maintenance of the sealing effectiveness even at low torque conditions.
Collapse
Affiliation(s)
- Pedro Ferrás Fernandes
- Faculty of Dental Medicine, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
| | - Liliana Grenho
- BoneLab, Laboratory for Bone Metabolism and Regeneration, Faculty of Dental Medicine, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
- LAQV/REQUIMTE, U. Porto, Porto, Portugal
| | - Maria Helena Fernandes
- BoneLab, Laboratory for Bone Metabolism and Regeneration, Faculty of Dental Medicine, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal
- LAQV/REQUIMTE, U. Porto, Porto, Portugal
| | | | - Pedro Sousa Gomes
- BoneLab, Laboratory for Bone Metabolism and Regeneration, Faculty of Dental Medicine, U. Porto, Rua Dr. Manuel Pereira da Silva, 4200-393, Porto, Portugal.
- LAQV/REQUIMTE, U. Porto, Porto, Portugal.
| |
Collapse
|
33
|
Gehrke P, Burg S, Peters U, Beikler T, Fischer C, Rupp F, Schweizer E, Weigl P, Sader R, Smeets R, Schäfer S. Bacterial translocation and microgap formation at a novel conical indexed implant abutment system for single crowns. Clin Oral Investig 2021; 26:1375-1389. [PMID: 34401947 PMCID: PMC8816325 DOI: 10.1007/s00784-021-04112-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 07/27/2021] [Indexed: 10/26/2022]
Abstract
OBJECTIVES A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. MATERIAL AND METHODS A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. RESULTS qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. CONCLUSIONS The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. CLINICAL RELEVANCE Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
Collapse
Affiliation(s)
- Peter Gehrke
- Department of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, 60528, Frankfurt am Main, Germany. .,Private Practice for Oral Surgery and Implant Dentistry, Bismarckstraße 27, 67059, Ludwigshafen, Germany.
| | - Simon Burg
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, 20251Hamburg, Germany
| | - Ulrike Peters
- Department of Periodontics, Preventive and Restorative Dentistry, University Medical Center Hamburg-Eppendorf, 20251, Hamburg, Germany
| | - Thomas Beikler
- Department of Periodontics, Preventive and Restorative Dentistry, University Medical Center Hamburg-Eppendorf, 20251, Hamburg, Germany
| | - Carsten Fischer
- Dental Laboratory, Sirius Ceramics, 60528, Frankfurt am Main, Germany
| | - Frank Rupp
- Section Medical Materials Science and Technology, University Hospital Tuebingen, 72076, Tuebingen, Germany
| | - Ernst Schweizer
- Section Medical Materials Science and Technology, University Hospital Tuebingen, 72076, Tuebingen, Germany
| | - Paul Weigl
- Department of Postgraduate Education, Center for Dentistry and Oral Medicine (Carolinum), University Hospital, Goethe University Frankfurt, 60528, Frankfurt am Main, Germany
| | - Robert Sader
- Department for Oral, Cranio-Maxillofacial and Facial Plastic Surgery, Medical Center, University Hospital, Goethe University Frankfurt, 60528, Frankfurt am Main, Germany
| | - Ralf Smeets
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, 20251Hamburg, Germany.,Department of Oral and Maxillofacial Surgery, Division of Regenerative Orofacial Medicine, University Hospital Hamburg-Eppendorf, 20251, Hamburg, Germany
| | - Sogand Schäfer
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, 20251Hamburg, Germany
| |
Collapse
|
34
|
Pera F, Menini M, Bagnasco F, Mussano F, Ambrogio G, Pesce P. Evaluation of internal and external hexagon connections in immediately loaded full-arch rehabilitations: A within-person randomized split-mouth controlled trial with a 3-year follow-up. Clin Implant Dent Relat Res 2021; 23:562-567. [PMID: 34219356 PMCID: PMC8457096 DOI: 10.1111/cid.13029] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Revised: 05/30/2021] [Accepted: 06/02/2021] [Indexed: 01/28/2023]
Abstract
BACKGROUND Although full-arch immediately loaded rehabilitations are widely used nowadays, little information is available on which implant/abutment connection is the most suitable in this type of treatment. PURPOSE The aim of the present multicentric split-mouth clinical trial was to compare the clinical outcomes of two different implant-abutment connections applied in full-arch immediate loading rehabilitations: external hexagon connection (EHC) versus internal hexagon connection (IHC). MATERIALS AND METHODS Twenty patients were rehabilitated with immediately loaded fixed full-arch rehabilitations. All the implants presented the same macro- and micro-topography but different implant/abutment connection. IHC were used in one randomly selected side of the jaw and EHC in the other side. Outcome measures were implant survival rate, peri-implant marginal bone loss (MBL), plaque index (PI), probing depth (PD), and bleeding on probing (BoP) evaluated at 3, 6, 12, and 36-month post-loading. Any technical and biological complication was recorded. Kaplan-Meier procedure and linear mixed model were used to perform statistical analysis. RESULTS Forty-three EHC and 40 IHC implants were inserted. No patients dropped out and two implants failed in the first 6 months. The CSR was 97.7% for EHC and 97.5% for IHC implants. No statistically significant differences were found among the two groups for any of the parameters at any time point. At the 36-month follow-up visit a slight difference was found in MBL with a mean value of 1.7 mm in the EHC and of 1.9 mm in the IHC group (p = 0.355). No biologic complications were identified. Seven loosed abutment screws were identified in the entire follow-up period, two in the EHC, and five in the IHC group without a statistically significant difference (p = 0.394). CONCLUSIONS After 36 months in function, both internal and external hexagon connections provided good clinical outcomes and were not associated with any significant difference.
Collapse
Affiliation(s)
- Francesco Pera
- CIR Dental School Department of Surgical Sciences, University of Turin, Torino, Italy
| | - Maria Menini
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, Genova, Italy
| | - Francesco Bagnasco
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, Genova, Italy
| | - Federico Mussano
- CIR Dental School Department of Surgical Sciences, University of Turin, Torino, Italy
| | - Giulia Ambrogio
- CIR Dental School Department of Surgical Sciences, University of Turin, Torino, Italy
| | - Paolo Pesce
- Department of Surgical Sciences (DISC), Division of Prosthodontics and Implant Prosthodontics, University of Genoa, Genova, Italy
| |
Collapse
|
35
|
Canullo L, Masucci L, Quaranta G, Patini R, Caponio VCA, Pesce P, Ravidà A, Penarrocha-Oltra D, Penarrocha-Diago M. Culturomic and quantitative real-time-polymerase chain reaction analyses for early contamination of abutments with different surfaces: A randomized clinical trial. Clin Implant Dent Relat Res 2021; 23:568-578. [PMID: 34196453 DOI: 10.1111/cid.13028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Revised: 05/16/2021] [Accepted: 06/02/2021] [Indexed: 11/27/2022]
Abstract
BACKGROUND Rough and/or plasma-activated abutments seem to be able to increase soft tissue adhesion and stability; however, limited evidence is available about bacterial contamination differences. PURPOSE The aim was to investigate the oral microbiota on four dental abutments with different surfaces by quantitative real-time polymerase chain reaction (qRT-PCR) and culturomic approach. METHODS Forty patients needing a single implant rehabilitation were involved in the study. Forty healing abutments, especially designed for the study, were divided into four groups according to the surface topography (1. machined [MAC], 2. machined plasma of argon treated [plasmaMAC], 3. ultrathin threaded microsurface [UTM], 4. UTM plasma of argon treated [Plasma UTM]). Random assignment was performed according to predefined randomization tables. All patients underwent surgical intervention for implant and contextual healing abutment positioning. After 2 months of healing, a sterile cotton swab was used for microbiological sampling for culturomics, while sterile paper points inserted into the sulcus were used for qRT-PCR. RESULTS At the end of the study, 36 patients completed all procedures and a total of 36 abutments (9 per group) were analyzed. qRT-PCR retrieved data for 23 bacterial species whereas culturomics revealed the presence of 74 different bacteria, most of them not routinely included into oral cavity microbiological kits of analysis or never found before in the oral microenvironment. No statistically significant differences emerged analyzing the four different surfaces (p = 0.053). On the contrary, higher total and specific bacterial counts were detected in the plasma-treated surfaces compared to the untreated ones (p = 0.021). CONCLUSIONS Abutments with different topographies and surface treatments resulted contaminated by similar oral bacterial flora. Abutments with moderately rough surface were not associated with a greater bacterial adhesion compared to machined ones. Conversely, more bacteria were found around plasma-treated abutments. Furthermore, data reported suggested to include new species not previously sought in the routine analyses of the oral bacterial microflora.
Collapse
Affiliation(s)
- Luigi Canullo
- Collaborating Professor of the Master in Oral Surgery and Implantology, University of Valencia, Valencia, Spain
| | - Luca Masucci
- Department of Microbiology and Virology, Fondazione Policlinico Universitario Agostino Gemelli, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Gianluca Quaranta
- Department of Microbiology and Virology, Fondazione Policlinico Universitario Agostino Gemelli, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Romeo Patini
- Institute of Dentistry and Maxillofacial Surgery, Fondazione Policlinico Universitario Agostino Gemelli, Università Cattolica del Sacro Cuore, Rome, Italy
| | | | - Paolo Pesce
- Department of Surgical Sciences (DISC), University of Genoa, Genoa, Italy
| | - Andrea Ravidà
- Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry, Ann Arbor, Michigan, USA
| | - David Penarrocha-Oltra
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Miguel Penarrocha-Diago
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| |
Collapse
|
36
|
Carlos LV, C Carlos N, Sm Karina L, K Sunil B, E Carlos P, G Olga L. Comparative study of bacterial microfiltration in the implant-abutment interface, with straight and conical internal connections, in vitro. Clin Exp Dent Res 2021; 7:1014-1024. [PMID: 34151544 PMCID: PMC8638306 DOI: 10.1002/cre2.439] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 03/25/2021] [Accepted: 04/01/2021] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE to determine the presence of marginal bacterial microfiltration in the IAI in different implant/abutment systems, in vitro. MATERIAL AND METHODS Fifty-six implants from seven different brand names, 4 with cone and 3 with straight connections were used, implant and abutment were connected using the Ncm tightening as indicated by each of the manufacturers and then were sealed. The samples were subjected occlusal load and thermal cycling, a first sample of each group was observed by micro CT and in a second sample (both samples randomly selected) length of connection was measured, while the rest of the samples were mounted on devices according to the bacterial microfiltration model with Porphyromonas gingivalis. RESULTS Two of the conical connection system groups did not present bacterial microfiltration, one of the three straight connection groups only microfiltered in one sample, while the other two conical as well as the two straight connection samples showed different and important levels of bacterial microfiltration, all groups presented a direct relationship between the implant-abutment adjustment determined by micro-CT and bacterial microfiltration levels, not related to the connection length. CONCLUSION Only two conical connection systems presented no bacterial microfiltration.
Collapse
Affiliation(s)
- Larrucea V Carlos
- Ex-Postgrado de Rehabilitación Oral, Universidad de Talca, Talca, Chile
| | - Navarro C Carlos
- Servicio de Cirugía Oral y Maxilofacial del Hospital General Universitario Gregorio Marañon de Madrid, Madrid, Spain
| | | | - Boda K Sunil
- MDRCBB-Minnesota Dental Research Center for Biomaterials and Biomechanics, University of Minnesota, Minneapolis, Minnesota, USA
| | - Padilla E Carlos
- Departamento de Microbiología, Universidad de Talca, Talca, Chile
| | - Lobos G Olga
- Departamento de Microbiología, Universidad de Talca, Talca, Chile
| |
Collapse
|
37
|
Lafuente-Ibáñez de Mendoza I, Cayero-Garay A, Quindós-Andrés G, Aguirre-Urizar JM. A systematic review on the implication of Candida in peri-implantitis. Int J Implant Dent 2021; 7:73. [PMID: 34136968 PMCID: PMC8209131 DOI: 10.1186/s40729-021-00338-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 03/30/2021] [Indexed: 01/17/2023] Open
Abstract
Background Candida is a heterogeneous fungal genus. Subgingival sulcus is a refuge for Candida, which has already been related to the pathogenic inflammation of periodontitis. This work aims to review the presence of Candida in the sulcular fluid surrounding dental implants and discuss its potential role in peri-implantitis. Results A bibliographical research was performed in PubMed, Scopus and Web of Science databases, with the keywords candida, peri-implantitis, periimplantitis, “dental implant” and implant. Newcastle-Ottawa Scale was used to assess the methodological quality of the included studies. At the end, nine observational studies were included, which analysed 400 dental implants with PI and 337 without peri-implantitis. Presence of Candida was assessed by traditional microbiological culture in blood agar or/and CHROMagar, though identification was also detected by quantitative real-time PCR, random amplified polymorphic DNA or ATB ID 32C. Dentate individuals and implants with peri-implantitis (range, 3–76.7%) had a bigger presence of Candida. C. albicans was the most isolated species, followed by Candida parapsilosis, Candida tropicalis, and Candida dubliniensis. Conclusion Candida is part of the microbiological profile of the peri-implant sulcular fluid. More studies are needed to compare the link between Candida and other microorganisms and to discover the true role of these fungi in peri-implantitis.
Collapse
Affiliation(s)
| | - Amaia Cayero-Garay
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Vizcaya, Spain
| | - Guillermo Quindós-Andrés
- Department of Immunology, Microbiology and Parasitology, University of the Basque Country (UPV/EHU), Leioa, Vizcaya, Spain
| | - José Manuel Aguirre-Urizar
- Department of Stomatology II, University of the Basque Country (UPV/EHU), Barrio Sarriena s/n, 48940, Leioa, Vizcaya, Spain.
| |
Collapse
|
38
|
Molinero-Mourelle P, Cascos-Sanchez R, Yilmaz B, Lam WYH, Pow EHN, Del Río Highsmith J, Gómez-Polo M. Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study. MATERIALS 2021; 14:ma14092348. [PMID: 33946477 PMCID: PMC8125438 DOI: 10.3390/ma14092348] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 04/20/2021] [Accepted: 04/27/2021] [Indexed: 01/03/2023]
Abstract
The aim of this in vitro study was to investigate the microgaps at the implant-abutment interface when zirconia (Zr) and CAD/CAM or cast Co-Cr abutments were used. METHODS Sixty-four conical connection implants and their abutments were divided into four groups (Co-Cr (milled, laser-sintered and castable) and Zirconia (milled)). After chewing simulation (300,000 cycles, under 200 N loads at 2 Hz at a 30° angle) and thermocycling (10,000 cycles, 5 to 50 °C, dwelling time 55 s), the implant-abutment microgap was measured 14 times at each of the four anatomical aspects on each specimen by using a scanning electron microscope (SEM). Kruskal-Wallis and pair-wise comparison were used to analyze the data (α = 0.05). RESULTS The SEM analysis revealed smaller microgaps with Co-Cr milled abutments (0.69-8.39 μm) followed by Zr abutments (0.12-6.57 μm), Co-Cr sintered (7.31-25.7 μm) and cast Co-Cr (1.68-85.97 μm). Statistically significant differences were found between milled and cast Co-Cr, milled and laser-sintered Co-Cr, and between Zr and cast and laser-sintered Co-Cr (p < 0.05). CONCLUSIONS The material and the abutment fabrication technique affected the implant-abutment microgap magnitude. The Zr and the milled Co-Cr presented smaller microgaps. Although the CAD/CAM abutments presented the most favorable values, all tested groups had microgaps within a range of 10 to 150 μm.
Collapse
Affiliation(s)
- Pedro Molinero-Mourelle
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (R.C.-S.); (J.D.R.H.); (M.G.-P.)
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3007 Bern, Switzerland;
- Correspondence: ; Tel.: +34-913941922
| | - Rocio Cascos-Sanchez
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (R.C.-S.); (J.D.R.H.); (M.G.-P.)
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3007 Bern, Switzerland;
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, 3007 Bern, Switzerland
| | - Walter Yu Hang Lam
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Sai Ying Pun, Hong Kong, China; (W.Y.H.L.); (E.H.N.P.)
| | - Edmond Ho Nang Pow
- Prosthodontics, Restorative Dental Sciences, Faculty of Dentistry, The University of Hong Kong, Sai Ying Pun, Hong Kong, China; (W.Y.H.L.); (E.H.N.P.)
| | - Jaime Del Río Highsmith
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (R.C.-S.); (J.D.R.H.); (M.G.-P.)
| | - Miguel Gómez-Polo
- Department of Conservative Dentistry and Orofacial Prosthodontics, Faculty of Dentistry, Complutense University of Madrid, 28040 Madrid, Spain; (R.C.-S.); (J.D.R.H.); (M.G.-P.)
| |
Collapse
|
39
|
New Generation of Fixture-Abutment Connection Combining Soft Tissue Design and Vertical Screw-Retained Restoration: 1-Year Clinical, Aesthetics and Radiographic Preliminary Evaluation. Dent J (Basel) 2021; 9:dj9040035. [PMID: 33804864 PMCID: PMC8063813 DOI: 10.3390/dj9040035] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/03/2021] [Accepted: 03/18/2021] [Indexed: 11/30/2022] Open
Abstract
Implant design factors and the abutment connection are correlated with crestal bone stability. The aim of the present study was to evaluate a new type of screw-retained prostheses delivered on tissue-level implants with conical external vertical seal and internal hexagon connection. Implants 4.25 mm in diameter and 10 mm in length (Prama, Sweden and Martina) were placed in partially edentulous patients needing at least one implant in the healed site, having sufficient bone volume. The implant neck was positioned above the bone crest. A healing abutment was placed according to a one-stage approach. Outcome measures were implant and prosthesis survival rate, any complications, marginal bone loss (MBL), periodontal parameters, and pink esthetic score (PES). Overall, 13 patients (4 women and 9 men; mean age 50 ± 22 years) with the same number of implants were treated and followed for one year after loading. At the 12-month follow up, no implant and no prosthesis failed, and no complications were experienced. The mean MBL experienced at the one year follow-up was 0.65 ± 0.48 mm. One year after loading, 2 out of 13 implants present bleeding on probing (15.4%), 4 out of 13 patients presented with plaque at the one year of follow-up (30.8%) and the PES was 10.5 ± 2.3 mm. Within the limitations of the present study, the analyzed implants seem to be a viable treatment option for the rehabilitation of a single tooth gap.
Collapse
|
40
|
Conte A, Ghiraldini B, Denófrio PHF, Ribeiro FV, Pimentel SP, Casati MZ, Corrêa MG, Cirano FR. Could implant position influence the peri-implant parameters in edentulous mandibles of diabetics rehabilitated with overdentures? A split-mouth randomized study. Int J Oral Maxillofac Surg 2021:S0901-5027(21)00088-6. [PMID: 33715937 DOI: 10.1016/j.ijom.2021.02.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 12/15/2020] [Accepted: 02/07/2021] [Indexed: 10/21/2022]
Abstract
This randomized controlled trial assessed the impact of crestal level position of implants installed in type 2 diabetes mellitus (T2DM) patients rehabilitated with overdentures. Twenty-two mandibular edentulous T2DM patients were submitted to implant placement for retention of an overdenture. By means of a split-mouth design, two implants were installed: one at supracrestal level (SL) and one at crestal level (CL). Clinical, immunoenzymatic and tomographic analyses were performed at prosthesis placement (baseline) and after 6, 12 and 24 months following implant loading. Increased peri-implant probing depths were detected in CL implants when compared with SL implants at all time-points (baseline P=0.047; 6 months P=0.014; 12 months P=0.027; 24 months P=0.036). Indeed, augmented clinical attachment levels were also detected in CL implants when compared with SL implants at all time-points (baseline P=003; 6 months P=0.045; 12 months P=0.029; 24 months P=0.026). CL implants demonstrated increased amounts of interleukin-6 (IL-6) at 6 months (P=0.043) and higher IL-17 (P=0.021), IL-21 (P=0.034) and tumour necrosis factor alpha (TNF-α) concentrations (P=0.030) at 24 months in comparison with SL implants. CL group revealed enhanced bone loss from baseline to 6 (P=0.032), 12 (P=0.043) and 24 months (P=0.028) when compared with SL. In conclusion, this study showed that implants placed supracrestally in T2DM patients rehabilitated with overdentures demonstrated lower bone loss and better clinical parameters with beneficial modulation of peri-implant immunoinflammatory biomarkers when compared with implants positioned at crestal level.
Collapse
Affiliation(s)
- A Conte
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - B Ghiraldini
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - P H F Denófrio
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - F V Ribeiro
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - S P Pimentel
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - M Z Casati
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - M G Corrêa
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil
| | - F R Cirano
- Dental Research Division, School of Dentistry, Paulista University, São Paulo, Brazil.
| |
Collapse
|
41
|
Tissue-level versus bone-level single implants in the anterior area rehabilitated with feather-edge crowns on conical implant abutments: An up to 5-year retrospective study. J Prosthet Dent 2021; 128:936-941. [PMID: 33715833 DOI: 10.1016/j.prosdent.2021.01.031] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2020] [Revised: 01/19/2021] [Accepted: 01/19/2021] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Limited information is available on the differences between tissue-level implants with an ultrathin threaded microsurface conical transmucosal portion and bone-level implants rehabilitated with conical custom abutments. PURPOSE The purpose of this retrospective study was to assess the outcomes of crowns designed as per the biologically oriented preparation technique (BOPT) cemented on conical titanium abutments on tissue-level and bone-level implants. MATERIAL AND METHODS Patients consecutively rehabilitated with a delayed loading protocol with anterior implant-supported single crowns with a feather-edge margin, in function for at least 4 years, were recruited and divided into 2 groups based on the implant type they had received: tissue-level implants with a conical transmucosal portion or bone-level implants rehabilitated with a conical abutment by following the platform switching concept. Bone resorption, pink esthetic score (PES), and white esthetic score (WES) were collected and analyzed. The nonparametric Mann-Whitney test was performed to analyze all parameters (α=.05 for all tests). RESULTS A total of 43 participants (48 implants) were included in the present study. The mean follow-up period was 4.5 years (range 52-64 months). A statistically significant difference (P=.004) was found in the mean ±standard deviation bone resorption between tissue-level implants (0.38 ±0.46 mm) and bone-level implants (0.83 ±0.58 mm). Higher values for both PES and WES were obtained in the tissue-level implant group. CONCLUSIONS Within the limitations of the present retrospective study, tissue-level implants with a conical transmucosal portion seem to provide a suitable alternative to bone-level implants in the anterior area.
Collapse
|
42
|
Marginal Adaptation and Microbial Leakage at Conometric Prosthetic Connections for Implant-Supported Single Crowns: An In Vitro Investigation. Int J Mol Sci 2021; 22:ijms22020881. [PMID: 33477311 PMCID: PMC7830972 DOI: 10.3390/ijms22020881] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/21/2020] [Accepted: 01/14/2021] [Indexed: 01/02/2023] Open
Abstract
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.
Collapse
|
43
|
Review of expandable dental implants. Br J Oral Maxillofac Surg 2020; 59:546-554. [PMID: 33865645 DOI: 10.1016/j.bjoms.2020.11.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Accepted: 11/23/2020] [Indexed: 12/17/2022]
Abstract
In the last few years the dental implants market has grown both in developed and developing countries, and is associated with high aesthetic expectations and well-being. Although the success rate of commercial implants is high, some problems associated with a lack of initial stability, marginal bony resorption, and periodontal health, remain, especially with immediate placement and loading. The market offers different designs of dental implants, but cylindrical and tapered devices that are fixed to the bone via an external thread are dominant. One lesser-known but potentially useful design is the expandable dental implant (EDI). This paper presents a review of expandable dental implants that encompasses a survey of the literature, published patents, and available commercial devices. We found 15 articles: prospective human trials (n=4), human case reports (n=3), published independent discussions of other articles (n=2), three big animal trials (n=3), and in silico studies (n=3). A total of 73 published patents were found and two expandable dental implants are commercially available to date. We propose a classification system that differentiates between the expansion mechanism and the origin of the expanding action. Some expandable designs have been shown to provide good primary stability, but evidence to date is limited. We encourage future clinical and biomechanical studies to clarify and optimise the potential benefits of these implants.
Collapse
|
44
|
Yu P, Zhi Li, Tan X, Yu H. Effect of sealing gel on the microleakage resistance and mechanical behavior during dynamic loading of 3 implant systems. J Prosthet Dent 2020; 127:308-317. [PMID: 33246561 DOI: 10.1016/j.prosdent.2020.05.030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 05/20/2020] [Accepted: 05/20/2020] [Indexed: 02/05/2023]
Abstract
STATEMENT OF PROBLEM Sealing products have been produced to reduce microleakage at the implant abutment interface. However, little is known about their effectiveness and any alterations in mechanical behavior of implant systems with their application. PURPOSE The purpose of this in vitro study was to evaluate the effect of a silicone sealing gel on implant abutment interface microleakage, abutment screw torque loss, and thread wear of implant systems in a simulated oral environment. MATERIAL AND METHODS Five specimens each of 3 implants systems (Nobel, Straumann, and WEGO) that included sealed and unsealed groups were analyzed (N=30). Before assembling the components, toluidine blue solution was injected to the implant intaglio cavity to evaluate implant abutment interface microleakage. After tightening to the recommended torque, 20 to 200 N of 30-degree off-axis dynamic force was applied at 2 Hz for 48 hours. The toluidine blue solution was extracted to test optical density values at 1, 3, 9, 24, 33, and 48 hours. Detorque values were measured before and after cycling loading, and torque loss rates were calculated. The abutment screw morphologies were observed by using scanning electron microscopy. The coefficient of friction tendency of applying sealing gel was explored with a ball-on-flat configuration. One-way ANOVA and Student t test were used for statistical analysis (α=.05). RESULTS The optical density value increased with the loading time, especially for Straumann group. The sealing gel decreased the implant abutment interface microleakage of Straumann assemblies after cyclic loading of 9 hours (P=.044), whereas no statistical difference was found for Nobel (P=.140) or WEGO groups (P=.402) at 6 time points. Torque loss occurred during tightening and further increased after dynamic cyclic load in each group. Among the 3 implant systems, Straumann implants reported the best antiloosening property (P<.001). The application of sealing gel reduced the initial (P=.048) and final (P=.032) torque loss rate in all the 3 systems. Scanning electron microscopy observations revealed the bottom thread tended to have more abrasion than the first thread. After applying sealing gel, less thread abrasion was found in Nobel and WEGO assemblies, whereas the protective effect was not evident for the Straumann group. The coefficient of friction of sealed group (0.17 ±0.026) was significantly (P=.012) lower than that of unsealed group (0.24 ±0.044). CONCLUSIONS The silicone sealing gel improved the immediate fastening and long-term antiloosening performances of 3 implant systems, decreased the implant abutment interface microleakage of Straumann system, and reduced abutment screw thread abrasion of the Nobel and WEGO systems.
Collapse
Affiliation(s)
- Ping Yu
- Doctoral candidate, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Zhi Li
- Resident Doctor, Aerospace Center Hospital, Beijing, PR China
| | - Xin Tan
- Doctoral candidate, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China
| | - Haiyang Yu
- Professor, State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
| |
Collapse
|
45
|
Dubar M, Clerc-Urmès I, Baumann C, Clément C, Alauzet C, Bisson C. Relations of Psychosocial Factors and Cortisol with Periodontal and Bacterial Parameters: A Prospective Clinical Study in 30 Patients with Periodontitis Before and After Non-Surgical Treatment. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17207651. [PMID: 33092182 PMCID: PMC7588876 DOI: 10.3390/ijerph17207651] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/18/2022]
Abstract
(1) Background: The progression of periodontitis, induced by polymicrobial dysbiosis, can be modified by systemic or environmental factors such as stress or anxiety affecting host response. The purpose of this study is to evaluate the potential associations between psychosocial factors scores or salivary cortisol levels with clinical periodontal parameters and bacterial environment in patients with periodontitis; (2) Methods: Subgingival microbiota was collected in two pathological and one healthy sites from thirty diseased patients (before/after scaling and root planing (SRP)) and from one healthy site from thirty control patients. Usual clinical periodontal parameters were recorded, and a saliva sample was harvested. Patients completed stress and anxiety self-assessment questionnaires. Cortisol concentrations were determined by ELISA and bacteria were identified by PCR; (3) Results: No correlation between salivary cortisol and the stress-anxiety self-declared was found (p > 0.05), but high concentrations of this molecule were associated positively and linearly with periodontal pocket depth (p = 0.04). It appeared that certain psychosocial stressors are associated with a modulation of the bacterial colonization of pockets of diseased group (before/after SRP), notably concerning Tannerella forsythia (p = 0.02), Porphyromonas gingivalis (p = 0.03), Fusobacterium nucleatum (p = 0.049) and Campylobacter rectus (p = 0.01). (4) Conclusion: This study reveals associations between bacteria colonization and psychosocial parameters in periodontitis that needs to be further investigated.
Collapse
Affiliation(s)
- Marie Dubar
- Department of Periodontology, School of Dentistry, Lille University Hospital, 59000 Lille, France
- Stress Immunity Pathogens Unit (SIMPA), EA 7300, University of Lorraine, F-54000 Nancy, France; (C.A.); (C.B.)
- Correspondence:
| | - Isabelle Clerc-Urmès
- Department of Methodology, Promotion and Investigation, UMDS, University Hospital of Nancy, 54500 Vandoeuvre-lès-Nancy, France; (I.C.-U.); (C.B.)
| | - Cédric Baumann
- Department of Methodology, Promotion and Investigation, UMDS, University Hospital of Nancy, 54500 Vandoeuvre-lès-Nancy, France; (I.C.-U.); (C.B.)
| | - Céline Clément
- CHRU Nancy, Department of Public Health Dentistry, University Hospital, 54000 Nancy, France;
- “Interpsy” Laboratory, University of Lorraine, EA 4432, CEDEX 54015 Nancy, France
- «Health Systemic Process» Laboratory, University Lyon 1, EA 4129, 69008 Lyon, France
| | - Corentine Alauzet
- Stress Immunity Pathogens Unit (SIMPA), EA 7300, University of Lorraine, F-54000 Nancy, France; (C.A.); (C.B.)
- CHRU Nancy, Microbiology Department, University Hospital, F-54000 Nancy, France
| | - Catherine Bisson
- Stress Immunity Pathogens Unit (SIMPA), EA 7300, University of Lorraine, F-54000 Nancy, France; (C.A.); (C.B.)
- Department of Periodontology, Nancy University Hospital, Lorraine University, 54500 Vandoeuvre-lès-Nancy, France
| |
Collapse
|
46
|
Is an internal tapered connection more efficient than an internal nontapered connection? A systematic review and meta-analysis. J Prosthet Dent 2020; 124:431-438. [DOI: 10.1016/j.prosdent.2019.07.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 07/26/2019] [Accepted: 07/26/2019] [Indexed: 01/11/2023]
|
47
|
Cosola S, Marconcini S, Boccuzzi M, Menchini Fabris GB, Covani U, Peñarrocha-Diago M, Peñarrocha-Oltra D. Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17186920. [PMID: 32971869 PMCID: PMC7557536 DOI: 10.3390/ijerph17186920] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 08/31/2020] [Accepted: 09/09/2020] [Indexed: 12/14/2022]
Abstract
Background: to assess the radiological marginal bone loss between bone-level or tissue-level dental implants through a systematic review of literature until September 2019. Methods: MEDLINE, Embase and other database were searched by two independent authors including only English articles. Results: The search provided 1028 records and, after removing the duplicates through titles and abstracts screening, 45 full-text articles were assessed for eligibility. For qualitative analysis 20 articles were included, 17 articles of them for quantitative analysis counting a total of 1161 patients (mean age 54.4 years) and 2933 implants, 1427 inserted at Tissue-level (TL) and 1506 inserted at Bone-level (BL). The survival rate and the success rate were more than 90%, except for 2 studies with a success rate of 88% and 86.2%. No studies reported any differences between groups in term of success and survival rates. Three studies showed that BL-implants had statistically less marginal bone loss (p < 0.05). Only one study reported statistically less marginal bone loss in TL-implants (p < 0.05). Conclusion: In the most part of the studies, differences between implant types in marginal bone loss were not statistically significant after a variable period of follow-up ranged between 1 and 5 years.
Collapse
Affiliation(s)
- Saverio Cosola
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
- Correspondence:
| | - Simone Marconcini
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Michela Boccuzzi
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Giovanni Battista Menchini Fabris
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
- Department of Stomatology, University of Studies Guglielmo Marconi, 44, 00193 Roma, Italy
| | - Ugo Covani
- Tuscan Stomatologic Institute, via Aurelia, 335, 55041 Lido di Camaiore, Italy; (S.M.); (M.B.); (G.B.M.F.); (U.C.)
| | - Miguel Peñarrocha-Diago
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
| | - David Peñarrocha-Oltra
- Oral Surgery Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 13, 46010 Valencia, Spain; (M.P.-D.); (D.P.-O.)
| |
Collapse
|
48
|
Misfit detection in implant-supported prostheses of different compositions by periapical radiography and cone beam computed tomography: An in vitro study. J Prosthet Dent 2020; 126:205-213. [PMID: 32723499 DOI: 10.1016/j.prosdent.2020.04.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Revised: 04/14/2020] [Accepted: 04/15/2020] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Misfits at the implant-abutment joint (IAJ) can cause the biological and mechanical failure of implant therapy. Standard parallel periapical radiography (PERI) is the method of choice for assessing the fitting of implant-supported prostheses. Although current guidelines do not support the use of cone beam computed tomography (CBCT) solely for misfit detection, CBCT scans can also register misfits as imaging findings. Whether the material used for prostheses manufacturing influences misfit appearance in PERI and CBCT images is unknown. PURPOSE The purpose of this in vitro study was to assess the influence of the type of prosthesis material on misfit detection at the IAJ by using PERI and CBCT. MATERIAL AND METHODS Thirty-two implants with an external hexagon connection were placed in dried human mandibles. Implant-supported crowns were manufactured with different materials and allocated to 3 experimental groups: metal-ceramic (MC), titanium abutment veneered with acrylic resin (TIT), and zirconia abutment veneered with glass-ceramic (ZIR). All crowns were installed both with and without a simulated 200-μm-thick gap at the IAJ (n=64) and were assessed by PERI and CBCT scans. Four dentists evaluated the images for the presence or absence of misfit. Statistical analysis included the Kappa test and areas under the receiver operating characteristics curve (Az values) comparisons (α=.05). RESULTS Kappa values indicated almost perfect intraevaluator and interevaluator reproducibility for PERI and ranged from fair to almost perfect for CBCT. For PERI, Az values were not significantly different among the MC (0.995), TIT (0.997), and ZIR groups (1.000) (P>.05). Regarding CBCT, the Az values found for TIT (0.941) and MC (0.890) were significantly higher than for ZIR (0.762) (P<.05). Az values for PERI were significantly higher than for CBCT (P<.05). CONCLUSIONS The type of prosthesis material did not influence misfit detection at the IAJ with PERI; however, ZIR had lower diagnostic accuracy than TIT and MC implant-supported crowns with CBCT.
Collapse
|
49
|
Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit. J Clin Med 2020; 9:jcm9082365. [PMID: 32722131 PMCID: PMC7463581 DOI: 10.3390/jcm9082365] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 07/18/2020] [Accepted: 07/22/2020] [Indexed: 12/26/2022] Open
Abstract
Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading and the misfit was measured by scanning electron microscopy. Data were analyzed with one-way ANOVA, t-test and Kruskal-Wallis test. Results: Significant differences (p < 0.001) were found between connections and abutments regardless of the torque applied. Morse taper connections with straight and angulated abutments showed the lowest misfit values (0.6 µm). Misfit values decreased as torque increased. Conclusions: The misfit was affected by the type of connection. The type of abutment did not influence the fit in the Morse taper connection. The higher the tightening torque applied the increase in the fit of the implant-abutment interface.
Collapse
|
50
|
Dubar M, Frippiat JP, Remen T, Boufenzer A, Alauzet C, Baumann C, Gibot S, Bisson C. Comparison of sTREM-1 and associated periodontal and bacterial factors before/after periodontal therapy, and impact of psychosocial factors. J Clin Periodontol 2020; 47:1064-1078. [PMID: 32602969 DOI: 10.1111/jcpe.13339] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Revised: 05/11/2020] [Accepted: 06/18/2020] [Indexed: 01/11/2023]
Abstract
AIM The immune receptor triggering receptor expressed on myeloid cell-1 (TREM-1) is responsible for an amplification of the immuno-inflammatory response in inflammatory diseases. Its role in the aetiopathogenesis of periodontitis is underexplored. The aim of this case-control and before-after study was to determine the evolution of soluble form of TREM-1 (sTREM-1) concentrations after scaling and root planing (SRP), and its prognostic value and evaluate associated microbial, periodontal and psychosocial factors. METHODS Gingival crevicular fluid was collected in two pathological sites (periodontal pocket depth (PPD) ≥ 5 mm) and one healthy site (PPD ≤ 3 mm) from thirty periodontitis patients (before/after SRP), and in one healthy site from thirty controls (patients without periodontal disease). Each patient filled-in stress/anxiety self-assessment questionnaires and provided a saliva sample. Diseased patients were followed for a total of 13-15 weeks in initial periodontal treatment. sTREM-1 and salivary cortisol levels were determined by ELISA and periodontopathogens by PCR. RESULTS Before SRP, higher crevicular sTREM-1 levels were positively associated with some increased clinical parameters (Plaque Index, tooth mobility, bleeding on probing, p < .05) and inversely with Aggregatibacter actinomycetemcomitans abundance (p = .03). No correlation with psychological factors nor cortisol was found with salivary sTREM-1 concentrations. After SRP, crevicular sTREM-1 levels decreased (p < .001) and were not linked to a PPD decrease but remained higher in pathological than in healthy sites (p < .001). Higher concentrations were also found out in unimproved sites (no change or increase in PPD) compared to improved ones (p = .02). Higher sTREM-1 levels were associated with Porphyromonas gingivalis, Treponema denticola and Campylobacter rectus in pathological sites after SRP (p < .05). CONCLUSION Crevicular sTREM-1 level decreased after SRP but did not appear to be a site outcome predictive factor of periodontal healing and remained an inflammatory parameter.
Collapse
Affiliation(s)
- Marie Dubar
- Department of Periodontology, School of Dentistry, Lille University Hospital, Lille, France.,Laboratory of Stress Immunity Pathogens, EA 7300, Faculty of Medicine, University of Lorraine, Vandoeuvre-lès-Nancy, France
| | - Jean-Pol Frippiat
- Laboratory of Stress Immunity Pathogens, EA 7300, Faculty of Medicine, University of Lorraine, Vandoeuvre-lès-Nancy, France
| | - Thomas Remen
- Clinical Research Support Facility PARC, UMDS, Nancy University Hospital, Vandoeuvre-lès-Nancy, France
| | | | - Corentine Alauzet
- Laboratory of Stress Immunity Pathogens, EA 7300, Faculty of Medicine, University of Lorraine, Vandoeuvre-lès-Nancy, France.,Laboratory of Bacteriology, Nancy University Hospital, University of Lorraine, Vandoeuvre-Lès-Nancy, France
| | - Cedric Baumann
- Clinical Research Support Facility PARC, UMDS, Nancy University Hospital, Vandoeuvre-lès-Nancy, France
| | - Sebastien Gibot
- Medical Intensive Care Unit, Hôpital Central, Nancy University Hospital, Nancy, France.,Department de Periodontology, Nancy University Hospital, University of Lorraine, Nancy, France
| | - Catherine Bisson
- Laboratory of Stress Immunity Pathogens, EA 7300, Faculty of Medicine, University of Lorraine, Vandoeuvre-lès-Nancy, France.,Department of Periodontology, University Hospital and University of Lorraine, Nancy, France
| |
Collapse
|