1
|
von Kobyletzki LB, Ulriksdotter J, Sukakul T, Aerts O, Agner T, Buhl T, Bruze M, Foti C, Gimenez-Arnau A, Gonçalo M, Hamnerius N, Johansen JD, Rustemeyer T, Stingeni L, Wilkinson M, Svedman C. Prevalence of dermatitis including allergic contact dermatitis from medical devices used by children and adults with Type 1 diabetes mellitus: A systematic review and questionnaire study. J Eur Acad Dermatol Venereol 2024. [PMID: 38400603 DOI: 10.1111/jdv.19908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence and prevalence of dermatitis in persons with T1D using MDs was conducted until December 2021. The Newcastle-Ottawa Scale was used to assess study quality. The inventory performed at EECRDG clinics focused on referral routes, patient numbers and the diagnostic process. Among the 3145 screened abstracts, 39 studies fulfilled the inclusion criteria. Sixteen studies included data on children only, 14 studies were on adults and nine studies reported data on both children and adults. Participants were exposed to a broad range of devices. Skin reactions were rarely specified. It was found that both the diagnostic process and referral routes differ in different centres. Further data on the prevalence of skin reactions related to MDs in individuals with T1D is needed and particularly studies where the skin reactions are correctly diagnosed. A correct diagnosis is delayed or hampered by the fact that, at present, the actual substances within the MDs are not declared, are changed without notice and the commercially available test materials are not adequately updated. Within Europe, routines for referral should be made more standardized to improve the diagnostic procedure when investigating patients with possible ACD from MDs.
Collapse
Affiliation(s)
- L B von Kobyletzki
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
- School of Medical Sciences, Örebro University, Örebro, Sweden
| | - J Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - T Sukakul
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - O Aerts
- Contact Allergy Unit, Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, University of Antwerp, Antwerp, Belgium
| | - T Agner
- Department of Dermatology, Bispebjerg University Hospital, Copenhagen, Denmark
| | - T Buhl
- Department of Dermatology, Venereology and Allergology, University Medical Center Göttingen, Göttingen, Germany
| | - M Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - C Foti
- Section of Dermatology, DIMEPREJ Department, University "Aldo Moro", Bari, Italy
| | - A Gimenez-Arnau
- Department of Dermatology, Hospital del Mar and Research Institute de Barcelona, Universitat Pompeu Fabra, Barcelona, Spain
| | - M Gonçalo
- Clinic of Dermatology, Coimbra University Hospital and Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - N Hamnerius
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - J D Johansen
- Department of Dermatology, Herlev and Gentofte Hospital, Copenhagen, Denmark
| | - T Rustemeyer
- Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - L Stingeni
- Dermatology Section, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - M Wilkinson
- Leeds Teaching Hospitals, NHS Trust, Leeds, UK
| | - C Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
2
|
Passanisi S, Berg AK, Chobot A, Dos Santos TJ, Piona CA, Messer L, Lombardo F. First International Survey on Diabetes Providers' Assessment of Skin Reactions in Youth With Type 1 Diabetes Using Technological Devices. J Diabetes Sci Technol 2023:19322968231206155. [PMID: 37846755 DOI: 10.1177/19322968231206155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
BACKGROUND Advances in diabetes technological devices led to optimization of diabetes care; however, long-lasting skin exposure to devices may be accompanied by an increasing occurrence of cutaneous reactions. METHODS We used an open-link web-based survey to evaluate diabetes-care providers' viewpoint on prevalence, management practices, and knowledge related to skin reactions with the use of diabetes technological devices. A post hoc analysis was applied to investigate differences in the level of awareness on this topic in relation to the experience in diabetes technology. RESULTS One hundred twenty-five responses from 39 different countries were collected. Most respondents (69%) routinely examine patients' skin at each visit. All the preventive measures are not clear and, mainly, homogenously put into clinical practice. Contact dermatitis was the most frequently reported cutaneous complication due to diabetes devices, and its most common provocative causes are not yet fully known by diabetes-care providers. Almost half of the respondents (42%) had discussed the presence of harmful allergens contained in adhesives with device manufacturers. There is general agreement on the need to strengthen knowledge on dermatological complications. CONCLUSIONS Although diabetes-care providers are quite aware of the chance to develop skin reactions in people with diabetes using technological devices, there are still some unmet needs. Large follow-up studies and further dissemination tools are awaited to address the gaps revealed by our survey.
Collapse
Affiliation(s)
- Stefano Passanisi
- Department of Human Pathology in Adult and Developmental Age "Gaetano Barresi," University of Messina, Messina, Italy
| | - Anna Korsgaard Berg
- Copenhagen University Hospital, Steno Diabetes Center Copenhagen, Herlev, Denmark
| | - Agata Chobot
- Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland
| | | | - Claudia Anita Piona
- Pediatric Diabetes and Metabolic Disorders Unit, Regional Center for Pediatric Diabetes, University City Hospital of Verona, Verona, Italy
| | - Laurel Messer
- Barbara Davis Center for Diabetes, University of Colorado Anschutz, Aurora, CO, USA
| | - Fortunato Lombardo
- Department of Human Pathology in Adult and Developmental Age "Gaetano Barresi," University of Messina, Messina, Italy
| |
Collapse
|
3
|
Passanisi S, Salzano G, Galletta F, Aramnejad S, Caminiti L, Pajno GB, Lombardo F. Technologies for Type 1 Diabetes and Contact Dermatitis: Therapeutic Tools and Clinical Outcomes in a Cohort of Pediatric Patients. Front Endocrinol (Lausanne) 2022; 13:846137. [PMID: 35370980 PMCID: PMC8965381 DOI: 10.3389/fendo.2022.846137] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 02/21/2022] [Indexed: 11/13/2022] Open
Abstract
The increasing use of technological devices for the management of diabetes is related to the prolonged exposure of patients' skin to chemical and mechanical agents and, consequently, to the increased risk of developing dermatological complications. Among these, contact dermatitis is the most insidious skin disorder. Despite the magnitude of the issue, no universally accepted recommendations on the management of this common complication are currently available. Our observational study aimed to describe all the solutions adopted by patients and their caregivers to treat and prevent the appearance of contact dermatitis and to describe the clinical impact of this cutaneous complication. Twenty-one pediatric patients (mean age 12.1 ± 3.7 years) with type 1 diabetes were recruited in the study. The most common treatment used to treat acute skin lesions was the application of topical corticosteroids, sometimes associated with topical antibiotics (9.5%). In order to prevent the further appearance of dermatitis, the most frequently adopted measure was the use of hydrocolloid and/or silicone-based adhesives, followed by the application of protective barrier films. One patient reported benefit from the off-label use of fluticasone propionate nasal spray. However, only 52.4% of the study participants achieved a definitive resolution of the skin issue, and 38.1% of patients were forced to discontinue insulin pump therapy and/or continuous glucose monitoring. No differences were observed in glycated hemoglobin values between the period before and after the onset of contact dermatitis. Our study confirms the severity of this dermatological complication that may hinder the spread of new technologies for the management of diabetes. Finally, our findings highlight the importance of establishing close collaboration both with pediatric allergy specialists to prescribe the most suitable treatment and with manufacturing companies to ensure that adhesives of technological devices are free of harmful well-known sensitizers.
Collapse
Affiliation(s)
- Stefano Passanisi
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Messina, Italy
- *Correspondence: Stefano Passanisi,
| | - Giuseppina Salzano
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Messina, Italy
| | - Francesca Galletta
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, Allergy Unit, University of Messina, Messina, Italy
| | - Sara Aramnejad
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Messina, Italy
| | - Lucia Caminiti
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, Allergy Unit, University of Messina, Messina, Italy
| | - Giovanni B. Pajno
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, Allergy Unit, University of Messina, Messina, Italy
| | - Fortunato Lombardo
- Department of Human Pathology in Adult and Developmental Age “Gaetano Barresi”, University of Messina, Messina, Italy
| |
Collapse
|
4
|
Gatica-Ortega ME, Mowitz M, Pastor-Nieto MA, Navarro-Triviño FJ, Fernández-Redondo V, Hernández-Cano N, Borrego L, Gómez-de-la-Fuente E, Torralba M, Svedman C, Giménez-Arnau A. Contact Dermatitis From Glucose Sensors In Spain: A Multicentric Approach. Contact Dermatitis 2021; 85:554-562. [PMID: 34185891 DOI: 10.1111/cod.13924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 06/06/2021] [Accepted: 06/27/2021] [Indexed: 12/01/2022]
Abstract
BACKGROUND Allergic contact dermatitis from glucose sensors may interfere with their ongoing application. OBJECTIVE To evaluate a series of Spanish patients with contact dermatitis to glucose sensors regarding former sources of contact allergens, patch test results and outcomes from the ongoing use of the device. METHODS A series of patients with contact dermatitis from glucose sensors was investigated in eight dermatology departments across Spain epidemiologic features, brands, latency time to develop dermatitis, the ability to continue using the devices as well as the patch test results. RESULTS Thirty patients were evaluated mean age: 20 .93 years. 66 .7 % were children and 66 .7 % female. 90 .0 % used Freestyle Libre FSL. 8 /26 30 .8 % reacted to isobornyl acrylate IBOA and 2 /20 10 .0 % to N,N dimethylacrylamide DMAA. The mean latency time to develop dermatitis was 9 months. 16 /29 55 .2 % patients continued using the same sensor causing the reaction. 13 /29 44 .8 % were unable to continue using the sensor due to severe reactions. Of them, 5 were positive to IBOA, one to IBOA and DMAA; one to DMAA; one to colophony and 1 to isopropyl alcohol wipes. In one patient the outcome was unknown. CONCLUSION The frequency of sensitization to IBOA and DMAA, was lower than in other European series, but similar to a previously published Spanish article. Legislation requiring manufacturers to provide information regarding medical devices composition and cooperate with the investigation of contact dermatitis is urgently needed. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | - Martin Mowitz
- Dept. of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - María A Pastor-Nieto
- Dermatology Dept. Hospital Universitario de Guadalajara Guadalajara, Spain.,Dept. of Medicine and Medical Specialties, Faculty of Medicine and Health Sciences, Faculty of Medicine, Alcalá University Alcalá de Henares, Madrid, Spain
| | | | | | | | - Leopoldo Borrego
- Universidad de Las Palmas de Gran Canaria. Dermatology Dept. Hospital Universitario Insular Dermatology Dept. Hospital Universitario Insular
| | | | - Miguel Torralba
- Dept. of Medicine and Medical Specialties, Faculty of Medicine and Health Sciences, Faculty of Medicine, Alcalá University Alcalá de Henares, Madrid, Spain.,Internal Medicine Dept., University Hospital of Guadalajara, Spain
| | - Cecilia Svedman
- Dept. of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Ana Giménez-Arnau
- Dermatology Dept. Hospital del Mar, IMIM, Universitat Autònoma de Barcelona
| |
Collapse
|
5
|
Ulriksdotter J, Mowitz M, Svedman C, Bruze M. Patch testing and diagnosis when suspecting allergic contact dermatitis from medical devices. Contact Dermatitis 2020; 83:333-335. [DOI: 10.1111/cod.13650] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 12/22/2022]
Affiliation(s)
- Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
- Department of Dermatology Helsingborg Hospital Helsingborg Sweden
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| |
Collapse
|
6
|
Ulriksdotter J, Svedman C, Bruze M, Glimsjö J, Källberg K, Sukakul T, Mowitz M. Contact dermatitis caused by glucose sensors-15 adult patients tested with a medical device patch test series. Contact Dermatitis 2020; 83:301-309. [PMID: 32608015 DOI: 10.1111/cod.13649] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 06/23/2020] [Accepted: 06/28/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND Several cases of allergic contact dermatitis (ACD) to the glucose sensor FreeStyle Libre have been reported. Isobornyl acrylate (IBOA) and N,N-dimethylacrylamide (DMAA) are known culprit allergens. OBJECTIVES To evaluate patients with suspected ACD to FreeStyle Libre in a standardized manner, present causative allergens, and assess patient-reported implications. METHODS A total of 15 patients with suspected ACD to FreeStyle Libre were patch tested with the Swedish baseline series and a new medical device series. IBOA and DMAA were tested at 0.1% and 0.3% in petrolatum (pet.). Readings were performed on day (D) 3 and D7. Background data, details on skin reactions, and associated implications were assessed using a questionnaire. RESULTS Thirteen patients were sensitized to IBOA and four to DMAA. Two positive reactions to IBOA and one to DMAA were seen only at 0.3% concentration on D7. Median duration of sensor use before dermatitis onset was 6 months. Half the number of the patients took precautions in everyday life due to sensor-related skin reactions. Six patients discontinued sensor usage. CONCLUSIONS Patients with suspected ACD to glucose sensors should be evaluated with a relevant patch test series containing IBOA and DMAA. Adding the 0.3% pet. concentration is recommended. The reading on D7 is necessary.
Collapse
Affiliation(s)
- Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Jenny Glimsjö
- Department of Medicine, Blekinge Hospital, Karlskrona, Sweden
| | - Kajsa Källberg
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Thanisorn Sukakul
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|