Mowitz M, Hosseini S, Siemund I, Ulriksdotter J, Svedman C. New device, 'old' allergens. Allergic contact dermatitis caused by the Dexcom G7 glucose sensor. Contact Dermatitis 2024; 90:495-500. [PMID: 38316128 DOI: 10.1111/cod.14514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 01/12/2024] [Accepted: 01/22/2024] [Indexed: 02/07/2024]
Abstract
BACKGROUND Allergic contact dermatitis (ACD) has been reported as an adverse effect from the use of several glucose sensors and insulin pumps from different manufacturers. Isobornyl acrylate (IBOA) has been identified as a major culprit sensitizer, but also other acrylates and (modified) colophonium have been reported as causes of ACD. OBJECTIVES To report the two first cases diagnosed with ACD caused by the Dexcom G7 (DG7) glucose sensor. PATIENTS AND METHODS Two children with suspected ACD from DG7 were patch tested with our medical device series with an addition of selected test preparations including two variants of modified colophonium - methyl hydrogenated rosinate (MHR) and glyceryl hydrogenated rosinate (GHR). Both patients were also tested with acetone extracts made from different parts of the DG7 sensor. The extracts were analysed by gas chromatography-mass spectrometry (GC-MS). RESULTS Both patients tested positive to IBOA, hydroabietyl alcohol and GHR. In addition, patient 1 had a positive reaction to MHR and patient 2 had a positive reaction to colophonium. The GC-MS analyses showed the presence of IBOA and colophonium-related substances in the DG7 extracts. CONCLUSIONS Both patients were diagnosed with contact allergy to well-known medical device-related sensitizers. The presence of IBOA and (modified) colophonium in a newly introduced (on the Swedish market in 2023) glucose sensor is remarkable and indicates an inadequate toxicological assessment of the materials used in the sensor.
Collapse
Affiliation(s)
- Martin Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Sarah Hosseini
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
- Department of Dermatology and Venereology, Ryhov County Hospital, Jönköping, Sweden
| | - Ingrid Siemund
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
2
|
Ulriksdotter J, Sukakul T, Bruze M, Mowitz M, Ofenloch R, Svedman C. Contact Allergy to Allergens in the Swedish Baseline Series Overrepresented in Diabetes Patients with Skin Reactions to Medical Devices - A Retrospective Study from Southern Sweden. Acta Derm Venereol 2024; 104:adv19676. [PMID: 38551376 PMCID: PMC11000652 DOI: 10.2340/actadv.v104.19676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 01/23/2024] [Indexed: 04/02/2024] Open
Abstract
Allergic contact dermatitis is reported among individuals using continuous glucose monitoring systems and insulin pumps. The aim of this study was to describe contact allergy patterns for allergens in the Swedish baseline series and medical device-related allergens among users. Contact allergy to baseline series allergens and isobornyl acrylate was compared between diabetes patients and dermatitis patients patch-tested at the Department of Occupational and Environmental Dermatology during 2017 to 2020. Fifty- four diabetes patients and 2,567 dermatitis patients were included. The prevalence of contact allergy to fragrance mix II and sesquiterpene lactone mix was significantly higher in diabetes patients compared with dermatitis patients. Of the diabetes patients 13.0% and of the dermatitis patients 0.5% tested positive to sesquiterpene lactone mix (p < 0.001). Of the diabetes patients 7.4% and of the dermatitis patients 2.3% tested positive to fragrance mix II (p = 0.041). Of the diabetes patients 70.4% tested positive to medical device-related allergens. Of the diabetes patients 63.0% and of the dermatitis patients 0.2% were allergic to isobornyl acrylate (p < 0.001). In conclusion, not only medical device-related contact allergies, but also contact allergy to baseline series allergens (fragrance mix II and sesquiterpene lactone mix), is overrepresented in diabetes patients who use medical devices.
Collapse
Affiliation(s)
- Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden; Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden .
| | - Thanisorn Sukakul
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Robert Ofenloch
- Occupational Dermatology, Department of Dermatology, University Hospital Heidelberg, Heidelberg, Germany
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
3
|
von Kobyletzki LB, Ulriksdotter J, Sukakul T, Aerts O, Agner T, Buhl T, Bruze M, Foti C, Gimenez-Arnau A, Gonçalo M, Hamnerius N, Johansen JD, Rustemeyer T, Stingeni L, Wilkinson M, Svedman C. Prevalence of dermatitis including allergic contact dermatitis from medical devices used by children and adults with Type 1 diabetes mellitus: A systematic review and questionnaire study. J Eur Acad Dermatol Venereol 2024. [PMID: 38400603 DOI: 10.1111/jdv.19908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence and prevalence of dermatitis in persons with T1D using MDs was conducted until December 2021. The Newcastle-Ottawa Scale was used to assess study quality. The inventory performed at EECRDG clinics focused on referral routes, patient numbers and the diagnostic process. Among the 3145 screened abstracts, 39 studies fulfilled the inclusion criteria. Sixteen studies included data on children only, 14 studies were on adults and nine studies reported data on both children and adults. Participants were exposed to a broad range of devices. Skin reactions were rarely specified. It was found that both the diagnostic process and referral routes differ in different centres. Further data on the prevalence of skin reactions related to MDs in individuals with T1D is needed and particularly studies where the skin reactions are correctly diagnosed. A correct diagnosis is delayed or hampered by the fact that, at present, the actual substances within the MDs are not declared, are changed without notice and the commercially available test materials are not adequately updated. Within Europe, routines for referral should be made more standardized to improve the diagnostic procedure when investigating patients with possible ACD from MDs.
Collapse
Affiliation(s)
- L B von Kobyletzki
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
- School of Medical Sciences, Örebro University, Örebro, Sweden
| | - J Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - T Sukakul
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - O Aerts
- Contact Allergy Unit, Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, University of Antwerp, Antwerp, Belgium
| | - T Agner
- Department of Dermatology, Bispebjerg University Hospital, Copenhagen, Denmark
| | - T Buhl
- Department of Dermatology, Venereology and Allergology, University Medical Center Göttingen, Göttingen, Germany
| | - M Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - C Foti
- Section of Dermatology, DIMEPREJ Department, University "Aldo Moro", Bari, Italy
| | - A Gimenez-Arnau
- Department of Dermatology, Hospital del Mar and Research Institute de Barcelona, Universitat Pompeu Fabra, Barcelona, Spain
| | - M Gonçalo
- Clinic of Dermatology, Coimbra University Hospital and Faculty of Medicine, University of Coimbra, Coimbra, Portugal
| | - N Hamnerius
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - J D Johansen
- Department of Dermatology, Herlev and Gentofte Hospital, Copenhagen, Denmark
| | - T Rustemeyer
- Dermato-Allergology and Occupational Dermatology, Amsterdam University Medical Centers, Amsterdam, The Netherlands
| | - L Stingeni
- Dermatology Section, Department of Medicine and Surgery, University of Perugia, Perugia, Italy
| | - M Wilkinson
- Leeds Teaching Hospitals, NHS Trust, Leeds, UK
| | - C Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
4
|
Ulriksdotter J, Mowitz M, Bruze M, Löndahl M, Svedman C. [Not Available]. Lakartidningen 2021; 118:21046. [PMID: 34637129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Affiliation(s)
- Josefin Ulriksdotter
- doktorand, ST-läkare, hudmottagningen, Helsingborgs lasarett; Yrkes- och miljödermatologiska avdelningen (YMDA), Skånes universitetssjukhus Malmö; institutionen för kliniska vetenskaper i Malmö, Lunds universitet
| | - Martin Mowitz
- PhD, kemist, Yrkes- och miljödermatologiska avdelningen (YMDA), Skånes universitetssjukhus Malmö; institutionen för kliniska vetenskaper i Malmö, Lunds universitet
| | - Magnus Bruze
- senior professor, överläkare, Yrkes- och miljödermatologiska avdelningen (YMDA), Skånes universitetssjukhus Malmö; institutionen för kliniska vetenskaper i Malmö, Lunds universitet
| | - Magnus Löndahl
- docent, överläkare, VE endokrinologi, VO EHRÖ, Skånes universitetssjukhus, Lund; institutionen för kliniska vetenskaper i Lund, Lunds universitet
| | - Cecilia Svedman
- professor, överläkare, Yrkes- och miljödermatologiska avdelningen (YMDA), Skånes universitetssjukhus Malmö; institutionen för kliniska vetenskaper i Malmö, Lunds universitet
| |
Collapse
|
5
|
Ulriksdotter J, Svedman C, Bruze M, Mowitz M. Allergic contact dermatitis caused by dipropylene glycol diacrylate in the Omnipod® insulin pump. Br J Dermatol 2021; 186:334-340. [PMID: 34510410 DOI: 10.1111/bjd.20751] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/07/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Cases of allergic contact dermatitis (ACD) caused by isobornyl acrylate (IBOA) in the Omnipod® insulin pump have previously been reported. OBJECTIVES To present three cases of patients with ACD caused by a new allergen in the pump, and results from chemical analyses. METHODS Omnipod pumps from different batches were analysed by gas chromatography-mass spectrometry. Aimed testing, with the department's medical device (MD) series and substances identified in the pump including dipropylene glycol diacrylate (DPGDA) at 0·01% and 0·1% in petrolatum (pet.), was performed. Patch testing also included extracts from the device, the adhesive patch as is, and allergens from baseline series. RESULTS All patients tested positive to 0·1% DPGDA in pet., and two patients additionally to a 0·01% concentration. DPGDA was found in extracts of the Omnipod pumps brought by the patients. An Omnipod pump from an earlier batch contained tripropylene glycol diacrylate, IBOA, N,N-dimethylacrylamide, di(ethylene glycol)ethyl ether acrylate (DEGEA) but no DPGDA. One of the patients reacted positively to all of these allergens except DEGEA, which was not tested. CONCLUSIONS When suspecting ACD to MDs, DPGDA at 0·1% in pet. should be tested. The contents of Omnipod have changed over time. Patch testing with updated test series and relevance assessment of positive reactions is a delicate task. Children, with lifelong use of MDs, risk contracting many allergies with potential cross-allergies. A question should be raised as to whether these low molecular weight acrylates should be used at all in devices constantly worn on the skin.
Collapse
Affiliation(s)
- J Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Helsingborg Hospital, Bergaliden 14, 251 87, Helsingborg, Sweden
| | - C Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - M Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - M Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|
6
|
Mowitz M, Ulriksdotter J, Bruze M, Svedman C. In Response to the Letter to the Editor on Minimizing Adverse Skin Reactions to Wearable Continuous Glucose Monitoring Sensors. J Diabetes Sci Technol 2021; 15:978-979. [PMID: 33880949 PMCID: PMC8258509 DOI: 10.1177/19322968211008241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Martin Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
- Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
- Cecilia Svedman, PhD, YMDA, VO EHRÖ Skåne University Hospital, SUS. Jan Waldenströmsg 16, Malmö, 205 02, Sweden.
| |
Collapse
|
7
|
Svedman C, Bruze M, Antelmi A, Hamnerius N, Hauksson I, Ulriksdotter J, Mowitz M. Continuous glucose monitoring systems give contact dermatitis in children and adults despite efforts of providing less ‘allergy‐ prone’ devices: investigation and advice hampered by insufficient material for optimized patch test investigations. J Eur Acad Dermatol Venereol 2021; 35:730-737. [DOI: 10.1111/jdv.16981] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 09/18/2020] [Indexed: 02/06/2023]
Affiliation(s)
- C. Svedman
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| | - M. Bruze
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| | - A. Antelmi
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| | - N. Hamnerius
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| | - I. Hauksson
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| | - J. Ulriksdotter
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
- Department of Dermatology Helsingborg Hospital Helsingborg Sweden
| | - M. Mowitz
- Department of Occupational and Environmental Dermatology Lund UniversitySkåne University Hospital Malmö Sweden
| |
Collapse
|
8
|
Svedman C, Ulriksdotter J, Lejding T, Bruze M, Mowitz M. Changes in adhesive ingredients in continuous glucose monitoring systems may induce new contact allergy pattern. Contact Dermatitis 2021; 84:439-446. [PMID: 33421157 DOI: 10.1111/cod.13781] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 12/28/2020] [Accepted: 12/30/2020] [Indexed: 12/18/2022]
Abstract
BACKGROUND Medical devices (MD) in close skin-contact for a prolonged time, such as glucose monitoring (CGM) systems, are a risk factor for contact allergy, and there has been an increase in patients using these. Correct diagnosis demands targetted testing. OBJECTIVES We report a new allergen in a continuous CGM system in which the adhesive was changed. The allergy pattern of the patients diagnosed is reported. METHODS The three patients reported were patch tested with an MD series, own material, and possible allergens found through analysis with gas chromatography-mass spectrometry, comparing analysis from the CGM system before and after change. RESULTS The patients were sensitized to isobornyl acrylate (IBOA), found in previously used devices and the present CGM. Apart from IBOA, the culprit allergen was found to be 2,2'-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate. CONCLUSION Allergic contact dermatitis due to CGM systems and insulin pumps are difficult to investigate and require chemical analysis. Because of the lack of information on substances used in the production, and when changes with MDs are initiated, it is difficult to advise patients, especially since they risk sensitization to several allergens. The use of MDs has increased and, thus, the need for collaboration between manufacturers, clinicians, and patient organizations.
Collapse
Affiliation(s)
- Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, SUS, University of Lund, Malmö, Sweden
| | - Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, SUS, University of Lund, Malmö, Sweden.,Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden University of Lund, Malmö, Sweden
| | - Tina Lejding
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, SUS, University of Lund, Malmö, Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, SUS, University of Lund, Malmö, Sweden
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology, Skåne University Hospital, SUS, University of Lund, Malmö, Sweden
| |
Collapse
|
9
|
Ulriksdotter J, Mowitz M, Svedman C, Bruze M. Patch testing and diagnosis when suspecting allergic contact dermatitis from medical devices. Contact Dermatitis 2020; 83:333-335. [DOI: 10.1111/cod.13650] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 12/22/2022]
Affiliation(s)
- Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
- Department of Dermatology Helsingborg Hospital Helsingborg Sweden
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology Lund University, Skåne University Hospital Malmö Sweden
| |
Collapse
|
10
|
Ulriksdotter J, Svedman C, Bruze M, Glimsjö J, Källberg K, Sukakul T, Mowitz M. Contact dermatitis caused by glucose sensors-15 adult patients tested with a medical device patch test series. Contact Dermatitis 2020; 83:301-309. [PMID: 32608015 DOI: 10.1111/cod.13649] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2020] [Revised: 06/23/2020] [Accepted: 06/28/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND Several cases of allergic contact dermatitis (ACD) to the glucose sensor FreeStyle Libre have been reported. Isobornyl acrylate (IBOA) and N,N-dimethylacrylamide (DMAA) are known culprit allergens. OBJECTIVES To evaluate patients with suspected ACD to FreeStyle Libre in a standardized manner, present causative allergens, and assess patient-reported implications. METHODS A total of 15 patients with suspected ACD to FreeStyle Libre were patch tested with the Swedish baseline series and a new medical device series. IBOA and DMAA were tested at 0.1% and 0.3% in petrolatum (pet.). Readings were performed on day (D) 3 and D7. Background data, details on skin reactions, and associated implications were assessed using a questionnaire. RESULTS Thirteen patients were sensitized to IBOA and four to DMAA. Two positive reactions to IBOA and one to DMAA were seen only at 0.3% concentration on D7. Median duration of sensor use before dermatitis onset was 6 months. Half the number of the patients took precautions in everyday life due to sensor-related skin reactions. Six patients discontinued sensor usage. CONCLUSIONS Patients with suspected ACD to glucose sensors should be evaluated with a relevant patch test series containing IBOA and DMAA. Adding the 0.3% pet. concentration is recommended. The reading on D7 is necessary.
Collapse
Affiliation(s)
- Josefin Ulriksdotter
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Helsingborg Hospital, Helsingborg, Sweden
| | - Cecilia Svedman
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Magnus Bruze
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Jenny Glimsjö
- Department of Medicine, Blekinge Hospital, Karlskrona, Sweden
| | - Kajsa Källberg
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Thanisorn Sukakul
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden.,Department of Dermatology, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Martin Mowitz
- Department of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| |
Collapse
|