1
|
Hyngstrom AS, Nguyen JN, Murphy SA, Raab SC, Schmit BD, Gutterman DD, Durand MJ. Reduced oxygen desaturation in the vastus lateralis of chronic stroke survivors during graded muscle contractions. Top Stroke Rehabil 2024; 31:513-526. [PMID: 38095272 PMCID: PMC11129930 DOI: 10.1080/10749357.2023.2291902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 12/02/2023] [Indexed: 01/27/2024]
Abstract
BACKGROUND Few studies have examined changes in skeletal muscle physiology post-stroke. This study examined changes in tissue oxygen saturation (StO2) of the vastus lateralis (VL) muscle of stroke survivors and age-matched control participants during maximal and submaximal isometric contractions of the knee extensor muscles. OBJECTIVES We hypothesized that tissue oxygen desaturation (ΔStO2) during knee extensor muscle contractions would be less in the VL in the paretic vs. the non-paretic and control legs. METHODS Ten chronic stroke survivors (>6 months post-stroke) with lower extremity muscle weakness and 10 age-matched controls completed this prospective cohort study. Maximum voluntary contractions (MVCs) of the knee extensor muscles were assessed with a Biodex dynamometer and StO2 of the VL was measured using near-infrared spectroscopy. RESULTS In the paretic leg of the stroke survivors little change in StO2 of the VL was observed during an MVC (ΔStO2 = -1.7 ± 1.8%) compared to the non-paretic (ΔStO2 = -5.1 ± 6.1%; p < 0.05) and control legs (ΔStO2 = -14.4 ± 8.8%; p < 0.05 vs. paretic and non-paretic leg). These differences remained when normalizing for strength differences between the legs. Compared to controls, both the paretic and non-paretic VL showed pronounced reductions in ΔStO2 during ramp and hold contractions equal to 20%, 40%, or 60% of the MVC (p < 0.05 vs. controls at all load levels). CONCLUSIONS These results indicate that oxygen desaturation in response to isometric muscle contractions is impaired in both the paretic and non-paretic leg muscle of stroke survivors compared to age-matched controls, and these differences are independent of differences in muscle strength.
Collapse
Affiliation(s)
| | - Jennifer N. Nguyen
- Department of Physical Medicine and Rehabilitation, Medical College of Wisconsin, Milwaukee, WI, USA, 53226
| | - Spencer A. Murphy
- Department of Physical Therapy, Marquette University, Milwaukee, WI, USA, 53233
| | - Stephanie C. Raab
- Department of Physical Therapy, Marquette University, Milwaukee, WI, USA, 53233
| | - Brian D. Schmit
- Department of Biomedical Engineering, Marquette University and the Medical College of Wisconsin, Milwaukee, WI, USA, 53226
| | - David D. Gutterman
- Department of Medicine, Medical College of Wisconsin, Milwaukee, WI, USA, 53226
- Cardiovascular Center, Medical College of Wisconsin, Milwaukee, WI, USA, 53226
| | - Matthew J. Durand
- Department of Physical Medicine and Rehabilitation, Medical College of Wisconsin, Milwaukee, WI, USA, 53226
- Cardiovascular Center, Medical College of Wisconsin, Milwaukee, WI, USA, 53226
| |
Collapse
|
2
|
Jones B, Waterworth S, Tallent J, Rogerson M, Morton C, Moran J, Southall-Edwards R, Cooper CE, McManus C. Cold-Water Immersion and Lower Limb Muscle Oxygen Consumption as Measured by Near-Infrared Spectroscopy in Trained Endurance Athletes. J Athl Train 2024; 59:317-324. [PMID: 37347152 PMCID: PMC10976338 DOI: 10.4085/1062-6050-0532.22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/23/2023]
Abstract
CONTEXT Cold-water immersion (CWI) has been reported to reduce tissue metabolism postimmersion, but physiological data are lacking regarding the muscle metabolic response to its application. Near-infrared spectroscopy (NIRS) is a noninvasive optical technique that can inform muscle hemodynamics and tissue metabolism. OBJECTIVE To investigate the effects of CWI at 2 water temperatures (10°C and 15°C) on NIRS-calculated measurements of muscle oxygen consumption (mVO2). DESIGN Crossover study. SETTING University sports rehabilitation center. PATIENTS OR OTHER PARTICIPANTS A total of 11 male National Collegiate Athletic Association Division II long-distance runners (age = 23.4 ± 3.4 years, height = 1.8 ± 0.1 m, mass = 68.8 ± 10.7 kg, mean adipose tissue thickness = 6.7 ± 2.7 mm). INTERVENTION(S) Cold-water immersion at 10°C and 15°C for 20 minutes. MAIN OUTCOME MEASURE(S) We calculated mVO2 preimmersion and postimmersion at water temperatures of 10°C and 15°C. Changes in tissue oxyhemoglobin (O2Hb), deoxyhemoglobin (HHb), total hemoglobin (tHb), hemoglobin difference (Hbdiff), and tissue saturation index (TSI %) were measured during the 20-minute immersion at both temperatures. RESULTS We observed a decrease in mVO2 after immersion at both 10°C and 15°C (F1,9 = 27.7801, P = .001). During the 20-minute immersion at both temperatures, we noted a main effect of time for O2Hb (F3,27 = 14.227, P = .001), HHb (F3,27 = 5.749, P = .009), tHb (F3,27 = 24.786, P = .001), and Hbdiff (F3,27 = 3.894, P = .020), in which values decreased over the course of immersion. Post hoc pairwise comparisons showed that these changes occurred within the final 5 minutes of immersion for tHb and O2Hb. CONCLUSIONS A 20-minute CWI at 10°C and 15°C led to a reduction in mVO2. This was greater after immersion at 10°C. The reduction in mVO2 suggests a decrease in muscle metabolic activity (ie, O2 use after CWI). Calculating mVO2 via the NIRS-occlusion technique may offer further insight into muscle metabolic responses beyond what is attainable from observing the NIRS primary signals.
Collapse
Affiliation(s)
- Ben Jones
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Sally Waterworth
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Jamie Tallent
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Mike Rogerson
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Chris Morton
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Jason Moran
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | | | - Chris E. Cooper
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| | - Chris McManus
- School of Sport, Rehabilitation and Exercise Sciences, University of Essex, Colchester, UK
| |
Collapse
|
3
|
Imai A, Yamaguchi K, Goto K. Comparison of systemic and peripheral responses during high-intensity interval exercise under voluntary hypoventilation vs. hypoxic conditions. Phys Act Nutr 2022; 26:8-16. [PMID: 35982624 PMCID: PMC9395251 DOI: 10.20463/pan.2022.0008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 06/02/2022] [Indexed: 11/22/2022] Open
Abstract
[Purpose] This study aimed to determine the systemic and peripheral responses to high-intensity interval exercise (HIIE) with voluntary hypoventilation at low lung volume (VHL) or HIIE under hypoxic conditions. [Methods] Ten male participants completed a single session of HIIE (three sets of 6 × 8-s high-intensity pedaling at 170% of maximal oxygen uptake [VO2max]) under three different conditions: normoxia with normal breathing (NOR: 23 °C, 20.9% of fraction of inspired oxygen [FiO2]), hypoxia with normal breathing (HYP: 23 °C, 14.5% FiO2), and normoxia with VHL (VHL: 23 °C, 20.9% FiO2). A randomized crossover design was used. Power output, arterial oxygen saturation (SpO2), heart rate, and muscle oxygenation were monitored during the exercise and the 16-s recovery. Muscle blood flow (mBF) of the vastus lateralis was also evaluated. [Results] SpO2 during the exercise and the 16-s recovery in the VHL group was significantly lower than in that of the NOR group. However, this parameter in the VHL group was significantly higher than that of the HYP group (NOR: 94.9 ± 0.4%, HYP: 82.8 ± 1.2%, VHL: 90.4 ± 0.5%; p < 0.001). Muscle oxygen saturation was significantly lower in the HYP group than those in the VHL and NOR groups (NOR: 79.6 ± 17.4%, HYP: 65.5 ± 7.7%, VHL: 74.4 ± 7.8%; p = 0.024). No significant difference in this parameter was observed between the VHL and NOR groups (p > 0.05). Additionally, the exercise-induced increase in mBF did not differ significantly among three groups (p > 0.05). [Conclusion] HIIE-induced SpO2 decrease was smaller under hypoxic conditions than during VHL. Moreover, mBF was not enhanced by the addition of VHL during HIIE.
Collapse
|
4
|
Evidence that large vessels do affect near infrared spectroscopy. Sci Rep 2022; 12:2155. [PMID: 35140261 PMCID: PMC8828816 DOI: 10.1038/s41598-022-05863-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 01/12/2022] [Indexed: 11/08/2022] Open
Abstract
The influence of large vessels on near infrared spectroscopy (NIRS) measurement is generally considered negligible. Aim of this study is to test the hypothesis that changes in the vessel size, by varying the amount of absorbed NIR light, could profoundly affect NIRS blood volume indexes. Changes in haemoglobin concentration (tHb) and in tissue haemoglobin index (THI) were monitored over the basilic vein (BV) and over the biceps muscle belly, in 11 subjects (7 M - 4 F; age 31 ± 8 year) with simultaneous ultrasound monitoring of BV size. The arm was subjected to venous occlusion, according to two pressure profiles: slow (from 0 to 60 mmHg in 135 s) and rapid (0 to 40 mmHg maintained for 30 s). Both tHb and THI detected a larger blood volume increase (1.7 to 4 fold; p < 0.01) and exhibited a faster increase and a greater convexity on the BV than on the muscle. In addition, NIRS signals from BV exhibited higher correlation with changes in BV size than from muscle (r = 0.91 vs 0.55, p < 0.001 for THI). A collection of individual relevant recordings is also included. These results challenge the long-standing belief that the NIRS measurement is unaffected by large vessels and support the concept that large veins may be a major determinant of blood volume changes in multiple experimental conditions.
Collapse
|
5
|
Sudakou A, Lange F, Isler H, Lanka P, Wojtkiewicz S, Sawosz P, Ostojic D, Wolf M, Pifferi A, Tachtsidis I, Liebert A, Gerega A. Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: validation for tissue oxygenation studies. BIOMEDICAL OPTICS EXPRESS 2021; 12:6629-6650. [PMID: 34745761 PMCID: PMC8548017 DOI: 10.1364/boe.431301] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 08/06/2021] [Accepted: 09/07/2021] [Indexed: 05/15/2023]
Abstract
We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system's performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.
Collapse
Affiliation(s)
- Aleh Sudakou
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Frédéric Lange
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Helene Isler
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Pranav Lanka
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | | | - Piotr Sawosz
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Daniel Ostojic
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Martin Wolf
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | - Ilias Tachtsidis
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Adam Liebert
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| |
Collapse
|
6
|
Biswas K, Gupta P, Kaushal A, Syed I. Spondylo-Epiphyseal dysplasia - A challenge for operative positioning. Indian J Anaesth 2021; 65:160-162. [PMID: 33776094 PMCID: PMC7983811 DOI: 10.4103/ija.ija_920_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 08/08/2020] [Accepted: 09/29/2020] [Indexed: 12/02/2022] Open
Affiliation(s)
- Konish Biswas
- Department of Anaesthesia, AIIMS, Rishikesh, Uttarakhand, India
| | - Priyanka Gupta
- Department of Anaesthesia, AIIMS, Rishikesh, Uttarakhand, India
| | | | - Ifthekar Syed
- Department of Orthopaedics, AIIMS, Rishikesh, Uttarakhand, India
| |
Collapse
|
7
|
Dennis JJ, Wiggins CC, Smith JR, Isautier JMJ, Johnson BD, Joyner MJ, Cross TJ. Measurement of muscle blood flow and O 2 uptake via near-infrared spectroscopy using a novel occlusion protocol. Sci Rep 2021; 11:918. [PMID: 33441688 PMCID: PMC7806775 DOI: 10.1038/s41598-020-79741-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 12/09/2020] [Indexed: 11/09/2022] Open
Abstract
We describe here a novel protocol that sequentially combines venous followed by arterial occlusions to determine muscle blood flow and O2 uptake from a single measurement point using near-infrared spectroscopy (NIRS) during handgrip exercise. NIRS data were obtained from the flexor digitorum superficialis (FDS) muscle on the dominant arm of 15 young, healthy adults (3 women; 26 ± 7 years; 78.6 ± 9.1 kg). Participants completed a series of 15-s static handgrip contractions at 20, 40 and 60% of maximal voluntary contraction (MVC) immediately followed by either a: (i) venous occlusion (VO); (ii); arterial occlusion (AO); or venous then arterial occlusion (COMBO). Each condition was repeated 3 times for each exercise-intensity. The concordance correlation coefficient (CCC) and robust linear mixed effects modeling were used to determine measurement agreement between vascular occlusion conditions. FDS muscle blood flow ([Formula: see text]) and conductance ([Formula: see text]) demonstrated strong absolute agreement between VO and COMBO trials from rest up to 60%MVC, as evidenced by high values for CCC (> 0.82) and a linear relationship between conditions that closely approximated the line-of-identity (perfect agreement). Conversely, although FDS muscle O2 uptake ([Formula: see text]) displayed "substantial" to "near perfect" agreement between methods across exercise intensities (i.e., CCC > 0.80), there was a tendency for COMBO trials to underestimate [Formula: see text] by up to 7%. These findings indicate that the COMBO method provides valid estimates of [Formula: see text] and, to a slightly lesser extent, [Formula: see text] at rest and during static handgrip exercise up to 60%MVC. Practical implications and suggested improvements of the method are discussed.
Collapse
Affiliation(s)
- Joshua J Dennis
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA
| | - Chad C Wiggins
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA
| | - Joshua R Smith
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Jennifer M J Isautier
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA.,Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia
| | - Bruce D Johnson
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA
| | - Michael J Joyner
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN, USA
| | - Troy J Cross
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN, USA. .,Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, 2006, Australia.
| |
Collapse
|
8
|
Karlas A, Kallmayer M, Fasoula NA, Liapis E, Bariotakis M, Krönke M, Anastasopoulou M, Reber J, Eckstein HH, Ntziachristos V. Multispectral optoacoustic tomography of muscle perfusion and oxygenation under arterial and venous occlusion: A human pilot study. JOURNAL OF BIOPHOTONICS 2020; 13:e201960169. [PMID: 32134550 DOI: 10.1002/jbio.201960169] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 01/26/2020] [Accepted: 02/11/2020] [Indexed: 05/21/2023]
Abstract
Perfusion and oxygenation are critical parameters of muscle metabolism in health and disease. They have been both the target of many studies, in particular using near-infrared spectroscopy (NIRS). However, difficulties with quantifying NIRS signals have limited a wide dissemination of the method to the clinics. Our aim was to investigate whether clinical multispectral optoacoustic tomography (MSOT) could enable the label-free imaging of muscle perfusion and oxygenation under clinically relevant challenges: the arterial and venous occlusion. We employed a hybrid clinical MSOT/ultrasound system equipped with a hand-held scanning probe to visualize hemodynamic and oxygenation changes in skeletal muscle under arterial and venous occlusions. Four (N = 4) healthy volunteers were scanned over the forearm for both 3-minute occlusion challenges. MSOT-recorded pathophysiologically expected results during tests of disturbed blood flow with high resolution and without the need for contrast agents. During arterial occlusion, MSOT-extracted Hb-values showed an increase, while HbO2 - and total blood volume (TBV)-values remained roughly steady, followed by a discrete increase during the hyperemic period after cuff deflation. During venous occlusion, results showed a clear increase in intramuscular HbO2 , Hb and TBV within the segmented muscle area. MSOT was found to be capable of label-free non-invasive imaging of muscle hemodynamics and oxygenation under arterial and venous occlusion. We introduce herein MSOT as a novel modality for the assessment of vascular disorders characterized by disturbed blood flow, such as acute limb ischemia and venous thrombosis.
Collapse
Affiliation(s)
- Angelos Karlas
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
- Clinic of Vascular and Endovascular Surgery, Technical University of Munich, Munich, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| | - Michael Kallmayer
- Clinic of Vascular and Endovascular Surgery, Technical University of Munich, Munich, Germany
| | - Nikolina-Alexia Fasoula
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Evangelos Liapis
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Michail Bariotakis
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Markus Krönke
- Clinic of Nuclear Medicine, Technical University of Munich, Klinikum Rechts der Isar, Germany
| | - Maria Anastasopoulou
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Josefine Reber
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
| | - Hans-Henning Eckstein
- Clinic of Vascular and Endovascular Surgery, Technical University of Munich, Munich, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| | - Vasilis Ntziachristos
- Chair for Biological Imaging, Center for Translational Cancer Research (TranslaTUM), Technical University of Munich, Munich, Germany
- Helmholtz Zentrum München, Institute of Biological and Medical Imaging, Neuherberg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany
| |
Collapse
|
9
|
Trexler ET, Keith DS, Lucero AA, Stoner L, Schwartz TA, Persky AM, Ryan ED, Smith-Ryan AE. Effects of Citrulline Malate and Beetroot Juice Supplementation on Energy Metabolism and Blood Flow During Submaximal Resistance Exercise. J Diet Suppl 2019; 17:698-717. [DOI: 10.1080/19390211.2019.1650866] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Affiliation(s)
- Eric T. Trexler
- Human Movement Science Curriculum, Department of Allied Health Sciences, University of North Carolina, Chapel Hill, NC, USA
- Applied Physiology Laboratory, Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC, USA
| | - Dale S. Keith
- Applied Physiology Laboratory, Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC, USA
| | - Adam A. Lucero
- School of Sport, Exercise and Nutrition, Massey University, Wellington, NZ
| | - Lee Stoner
- Human Movement Science Curriculum, Department of Allied Health Sciences, University of North Carolina, Chapel Hill, NC, USA
- Applied Physiology Laboratory, Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC, USA
| | - Todd A. Schwartz
- Department of Biostatistics, Gillings School of Global Public Health, University of North Carolina, Chapel Hill, NC, USA
| | - Adam M. Persky
- Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC, USA
| | - Eric D. Ryan
- Human Movement Science Curriculum, Department of Allied Health Sciences, University of North Carolina, Chapel Hill, NC, USA
- Applied Physiology Laboratory, Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC, USA
| | - Abbie E. Smith-Ryan
- Human Movement Science Curriculum, Department of Allied Health Sciences, University of North Carolina, Chapel Hill, NC, USA
- Applied Physiology Laboratory, Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC, USA
| |
Collapse
|
10
|
Barstow TJ. Understanding near infrared spectroscopy and its application to skeletal muscle research. J Appl Physiol (1985) 2019; 126:1360-1376. [PMID: 30844336 DOI: 10.1152/japplphysiol.00166.2018] [Citation(s) in RCA: 250] [Impact Index Per Article: 41.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
Near infrared spectroscopy (NIRS) is a powerful noninvasive tool with which to study the matching of oxygen delivery to oxygen utilization and the number of new publications utilizing this technique has increased exponentially in the last 20 yr. By measuring the state of oxygenation of the primary heme compounds in skeletal muscle (hemoglobin and myoglobin), greater understanding of the underlying control mechanisms that couple perfusive and diffusive oxygen delivery to oxidative metabolism can be gained from the laboratory to the athletic field to the intensive care unit or emergency room. However, the field of NIRS has been complicated by the diversity of instrumentation, the inherent limitations of some of these technologies, the associated diversity of terminology, and a general lack of standardization of protocols. This Cores of Reproducibility in Physiology (CORP) will describe in basic but important detail the most common methodologies of NIRS, their strengths and limitations, and discuss some of the potential confounding factors that can affect the quality and reproducibility of NIRS data. Recommendations are provided to reduce the variability and errors in data collection, analysis, and interpretation. The goal of this CORP is to provide readers with a greater understanding of the methodology, limitations, and best practices so as to improve the reproducibility of NIRS research in skeletal muscle.
Collapse
Affiliation(s)
- Thomas J Barstow
- Department of Kinesiology, Kansas State University , Manhattan, Kansas
| |
Collapse
|
11
|
Cuff inflation time significantly affects blood flow recorded with venous occlusion plethysmography. Eur J Appl Physiol 2019; 119:665-674. [PMID: 30617468 PMCID: PMC6394686 DOI: 10.1007/s00421-018-04056-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2018] [Accepted: 12/13/2018] [Indexed: 12/22/2022]
Abstract
Purpose We tested whether the values of limb blood flow calculated with strain-gauge venous occlusion plethysmography (VOP) differ when venous occlusion is achieved by automated, or manual inflation, so providing rapid and slower inflation, respectively. Method In 9 subjects (20–30 years), we calculated forearm blood flows (FBF) values at rest and following isometric handgrip at 70% maximum voluntary contraction (MVC) when rapid, or slower inflation was used. Result Rapid and slower cuff inflation took 0.23 ± 0.01 (mean ± SEM) and 0.92 ± 0.02 s, respectively, reflecting the range reported in published studies. At rest, FBF calculated from the 1st cardiac cycle after rapid and slower inflation gave similar values: 10.5 ± 1.4 vs. 9.6 ± 1.3 ml dl− 1 min− 1, respectively (P > 0.05). However, immediately post-contraction, FBF was ~ 40% lower with slower inflation: 54.6 ± 5.1 vs. 33.8 ± 4.2 ml dl− 1 min− 1 (P < 0.01). The latter value was similar to that calculated over the 3rd cardiac cycle following rapid inflation: 2nd cardiac cycle: 40.5 ± 4.5; 3rd cycle: 32.6 ± 4.5 ml dl− 1 min− 1. Regression analyses of FBFs recorded at intervals post-contraction showed those calculated over the 1st, 2nd, or 3rd cardiac cycles with rapid inflation correlated well with those from the 1st cardiac cycle with manual inflation (r = 0.79, 0.82, 0.79; P < 0.01). However, only the slope for the 3rd cycle with rapid inflation vs. slower inflation was close to unity (2.07, 1.34, and 0.94, respectively). Conclusion These findings confirm that the 1st cardiac cycle following venous occlusion should be used when calculating FBF using VOP and, but importantly, indicate that cuff inflation should be almost instantaneous; just ≥ 0.9 s leads to substantial underestimation, especially at high flows.
Collapse
|
12
|
Black MJ, Lucero AA, Fink PW, Stoner L, Shultz SP, Lark SD, Rowlands DS. The Effects of Uniquely-Processed Titanium on Balance and Walking Performance in Healthy Older Adults. J Funct Biomater 2018; 9:jfb9020039. [PMID: 29890664 PMCID: PMC6023395 DOI: 10.3390/jfb9020039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2018] [Revised: 06/01/2018] [Accepted: 06/05/2018] [Indexed: 12/03/2022] Open
Abstract
The increased risk of falls associated with advancing age has increased demand for methods to improve balance and mobility. The primary purpose of the study was to determine whether wearing Aqua Titan-treated stockings could improve balance and walking performance in an older population; secondary was to elucidate the mechanisms. In a randomized, double-blind crossover, 16 healthy older adults (age, 67.9 ± 4.2 years; BMI, 24.8 ± 3.1 kg/m2) performed two 4-day trials composed of baseline measures and fatiguing exercise on Day 1, with recovery measures at 14, 38 and 62 h post-exercise, wearing Aqua Titan and control stockings. Balance, walking performance, triceps surae stretch reflex, ankle range of motion and gastrocnemius muscle microvascular perfusion, blood flow and oxygen consumption were measured at baseline and during recovery. Aqua Titan had no effect on the microvascular parameters, but increased total ankle range of motion at 38 h (2.4°; 95% CI ± 1.8°) and 62 h (2.7°; ±1.7°), contributed to by increases in dorsiflexion and plantar flexion. There was decreasing persistence in the medial-lateral center of pressure movement at 38 h (q = 0, −0.0635 ± 0.0455), compared to control stockings. Aqua Titan garments hold potential for improving balance and mobility in older adults in the days following a bout of fatiguing exercise. The proposed mechanisms associated with enhanced sensory feedback require further exploration.
Collapse
Affiliation(s)
- Melissa J Black
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| | - Adam A Lucero
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| | - Philip W Fink
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| | - Lee Stoner
- Department of Exercise and Sport Science, University of North Carolina, Chapel Hill, NC 27514, USA.
| | - Sarah P Shultz
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| | - Sally D Lark
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| | - David S Rowlands
- School of Sport, Exercise and Nutrition, Massey University, Wellington 6021, New Zealand.
| |
Collapse
|
13
|
Lucero AA, Addae G, Lawrence W, Neway B, Credeur DP, Faulkner J, Rowlands D, Stoner L. Reliability of muscle blood flow and oxygen consumption response from exercise using near-infrared spectroscopy. Exp Physiol 2017; 103:90-100. [DOI: 10.1113/ep086537] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Accepted: 10/13/2017] [Indexed: 01/21/2023]
Affiliation(s)
- Adam A. Lucero
- School of Sport & Exercise; Massey University; Wellington New Zealand
| | - Gifty Addae
- School of Public Health; Harvard; Boston MA USA
| | | | | | | | - James Faulkner
- Department of Sport and Exercise; University of Winchester; Winchester UK
| | - David Rowlands
- School of Sport & Exercise; Massey University; Wellington New Zealand
| | - Lee Stoner
- School of Sport & Exercise; Massey University; Wellington New Zealand
- Department of Exercise and Sport Science; University of North Carolina at Chapel Hill; NC USA
| |
Collapse
|