1
|
Garcia-Queiruga J, Pena-Verdeal H, Ferreiro-Figueiras D, Noya-Padin V, Giraldez MJ, Yebra-Pimentel E. Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month. Ophthalmic Physiol Opt 2024; 44:876-883. [PMID: 38712751 DOI: 10.1111/opo.13328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/22/2024] [Accepted: 04/24/2024] [Indexed: 05/08/2024]
Abstract
OBJECTIVE This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.
Collapse
Affiliation(s)
- Jacobo Garcia-Queiruga
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Hugo Pena-Verdeal
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Dolores Ferreiro-Figueiras
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Veronica Noya-Padin
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Maria J Giraldez
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| |
Collapse
|
2
|
Yuan W, Zhao F, Liu X, Xu J. Development of corneal contact lens materials and current clinical application of contact lenses: A review. Biointerphases 2023; 18:050801. [PMID: 37756594 DOI: 10.1116/6.0002618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 08/31/2023] [Indexed: 09/29/2023] Open
Abstract
Unlike conventional glasses, corneal contact lenses (CLs) can directly contact the surface of the tear film through the application of biopolymer materials, to achieve therapeutic and cosmetic purposes. Since the advent of polymethylmethacrylate, a material that has gained widespread use and attention, statistically, there are now more than 150 × 106 people around the world who wear corneal contact lenses. However, the associated complications caused by the interaction of contact lenses with the ocular surface, tear film, endogenous and environmental microorganisms, and components of the solution affect nearly one-third of the wearer population. The application of corneal contact lenses in correcting vision and myopia control has been widely recognized. With the development of related materials, corneal contact lenses are applied to the treatment of ocular surface diseases, including corneal bandage lenses, drug-loaded corneal contact lenses, biosensors, and other new products, while minimizing the side effects associated with CL wear. This paper summarized the development history and material properties of CLs, focused on the current main clinical applications and mechanisms, as well as clarified the possible complications in wearing therapeutic contact lenses and the direction for improvement in the future.
Collapse
Affiliation(s)
- Weichen Yuan
- Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang 110005, China
| | - Fangkun Zhao
- Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang 110005, China
| | - Xiaoyu Liu
- Department of Ophthalmology, Dalian Third People's Hospital Affiliated to Dalian Medical University, Dalian 116033, China
| | - Jun Xu
- Department of Ophthalmology, Dalian Third People's Hospital Affiliated to Dalian Medical University, Dalian 116033, China
| |
Collapse
|
3
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
4
|
Yokoi N, Eftimov P, Georgiev GA. Dynamic Aspects of Pre-Soft Contact Lens Tear Film and Their Relation to Dry Eye: Basic Science and Clinical Relevance. Life (Basel) 2023; 13:life13040859. [PMID: 37109389 PMCID: PMC10142029 DOI: 10.3390/life13040859] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 02/17/2023] [Accepted: 03/16/2023] [Indexed: 04/29/2023] Open
Abstract
Soft contact lens (SCL) perturbs the intimate connection between the pre-lens tear film (PLTF) and the ocular surface in various ways, i.e., (i) decrease in tear meniscus radius and aqueous tear thickness, (ii) attenuation of tear film lipid layer spread, (iii) limited wettability of SCL surface, (iv) increased friction with eyelid wiper, etc. This often results in SCL-related dry eye (SCLRDE) manifested as PLTF instability and contact lens discomfort (CLD). In this review, the individual contributions of factors (i-iv) to PLTF breakup patterns (BUP) and CLD are considered via the tear film-oriented diagnosis framework adopted by the Asia Dry Eye Society from a clinical and basic science perspective. It is shown that SCLRDE (due to aqueous deficiency, increased evaporation, or decreased wettability) and BUP of PLTF classify within the same types as the ones observed for the precorneal tear film. The analysis of PLTF dynamics reveals that the inclusion of SCL enhances the manifestation of BUP associated with (i) decreased thickness of PLTF aqueous layer and (ii) limited SCL wettability as shown by the rapid expansion of BUP area. PLTF thinness and instability result in increased blink-related friction and lid wiper epitheliopathy as major contributor to CLD.
Collapse
Affiliation(s)
- Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan
| | - Petar Eftimov
- Department of Cell and Developmental Biology, Faculty of Biology, Sofia University "St. Kliment Ohridski", 1164 Sofia, Bulgaria
| | - Georgi As Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, Sofia University "St. Kliment Ohridski", 1164 Sofia, Bulgaria
| |
Collapse
|
5
|
Pena-Verdeal H, Noya-Padin V, Losada-Oubiña M, Saborido-Rey M, Vilas-Alonso M, Giraldez MJ. Changes of symptomatology, tear film and ocular surface integrity one week during Somofilcon-A and Omafilcon-A lens wear. Eur J Ophthalmol 2022; 33:11206721221131131. [PMID: 36214157 DOI: 10.1177/11206721221131131] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2024]
Abstract
PURPOSE Clinicians play a key role in prescribing contact lenses that best suited for fitting which materials had an impact on ocular surface parameters. The present study aimed to evaluate the impact on symptomatology, tear film dynamics and ocular surface integrity of a silicone-hydrogel (Somofilcon-A) and a hydrogel (Omafilcon-A) lens before and after wearing for one week in contact lens neophyte participants. METHODS A Somofilcon-A and Omafilcon-A were randomly fitted to one or other the eye on an initial group of 28 participants. Subjects were scheduled for three sessions: basal session previous fitting, second session after 4-wear hours, and final session after 7-wear days for up to 10 h. In each session, CLDEQ-8, tear meniscus height and hyperemia with and without lenses, as well as lipid layer thickness and corneal/conjunctival staining without lenses were assessed. Values were compared between lenses and sessions. RESULTS In intrasession comparison, there were no differences in any parameter between materials on any session with or without lenses (all p≥0.176), except on the conjunctival staining where values obtained during Somofilcon-A wear (all p ≤ 0.006). In intersession analysis, CLDEQ-8 score, tear meniscus height and lipid layer thickness showed a statistical difference during both materials wear (all p ≤ 0.009), while conjunctival hyperemia does not (p = 0.237); corneal staining showed differences during Omafilcon-A wear (p = 0.037), contrary to conjunctival staining which showed differences only during Somofilcon-A wear (p < 0.001). CONCLUSION Contact lenses wear had an impact on ocular parameters that have some specific influences of the material on which lenses were manufactured.
Collapse
Affiliation(s)
- Hugo Pena-Verdeal
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Veronica Noya-Padin
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Martin Losada-Oubiña
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Marcos Saborido-Rey
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Manuel Vilas-Alonso
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| | - Maria J Giraldez
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, 16780Universidade de Santiago de Compostela, Santiago de Compostela (Galicia), Spain
| |
Collapse
|
6
|
Vera J, Redondo B, Molina R, Jiménez R. Effects of wearing swimming goggles on non-invasive tear break-up time in a laboratory setting. JOURNAL OF OPTOMETRY 2022; 15:154-159. [PMID: 33478924 PMCID: PMC9068525 DOI: 10.1016/j.optom.2020.09.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 09/07/2020] [Accepted: 09/18/2020] [Indexed: 06/12/2023]
Abstract
PURPOSE The use of swimming goggles (SG) has demonstrated to alter different ocular parameters, however, the impact of wearing SG on the tear film stability remain unknown. The main objective of this study was to determine the short-term effects of wearing SG on tear film surface quality break-up time (TFSQ-BUT). METHODS Twenty-eight young healthy adults (14 men and 14 women) wore a drilled SG, and TFSQ-BUT was measured before, during and after SG use. Dynamic-area high-speed videokeratoscopy was used for the non-invasive assessment of TFSQ-BUT. RESULTS TFSQ-BUT was significantly reduced while SG wear in comparison to the baseline measurement (4.8 ± 4.5 s vs. 8.8 ± 6.9 s; corrected p-value = 0.017, d = 0.57, mean difference = 4.0 [0.6, 7.3]; 45% reduction). Immediately after SG removal, TFSQ-BUT rapidly recovered baseline levels (8.2 ± 5.9 s vs. 8.8 ± 6.9 s; corrected p-value = 0.744). The impact of wearing SG on TFSQ-BUT were independent of the gender of the participants (p = 0.934). CONCLUSION The use of SG induces a TFSQ-BUT reduction, with these changes returning to baseline levels immediately after SG removal. These data may be of relevance for the management of dry eye patients, who need to avoid circumstances that exacerbate tear film instability. Nevertheless, these results must be interpreted with caution since the experiment did not entirely mimic real-life conditions (e.g., eye cup piece drilled, time of exposure, environmental conditions). Future studies should consider the inclusion of dry eye patients and older individual in order to explore the generalizability of these findings.
Collapse
Affiliation(s)
- Jesús Vera
- Department of Optics, Faculty of Sciences, University of Granada, Spain
| | - Beatríz Redondo
- Department of Optics, Faculty of Sciences, University of Granada, Spain.
| | - Rubén Molina
- Department of Optics, Faculty of Sciences, University of Granada, Spain
| | - Raimundo Jiménez
- Department of Optics, Faculty of Sciences, University of Granada, Spain
| |
Collapse
|
7
|
Xu Y, Xu Z, Shu X, Liu Q, Wang Y, Xia J, Li Y, Qu J, Hu L. Dynamic Changes of Ocular Surface in First-Time Contact Lens Wearers and the Effective Factors of Contact Lens Discomfort. Front Med (Lausanne) 2022; 9:833962. [PMID: 35360725 PMCID: PMC8962650 DOI: 10.3389/fmed.2022.833962] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2021] [Accepted: 02/04/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose The purpose of the study is to investigate the dynamic changes in ocular surface indicators in first-time contact lens (CL) wearers and identify the most influential factors in CL discomfort (CLD). Methods A total of 26 healthy non-CL wearers (26 eyes) were recruited and fitted monthly with disposable hydrogel CLs. Each participant underwent a full ocular surface evaluation, which include Efron grading, tear film breakup time, Schirmer's I test, corneal dendritic cell (DCs) imaging by in vivo confocal microscopy (IVCM), and conjunctival microvasculature evaluation by functional slit-lamp biomicroscopy. CLD was assessed using the Ocular Surface Disease Index questionnaire at baseline, 1 week, 1, 3, and 6 months after wearing it and another 6 months after discontinuing it. Results Clinical signs and CLD were significantly increased in the first week (p < 0.05). The microvascular response and DC activation peaked at the 1-month interval (p < 0.05). During CL wear, CLD is positively correlated with corneal staining (B = 0.238, p = 0.002), papillary conjunctivitis (B = 0.245, p < 0.001), and microvascular blood flow velocity (B = 0.353, p < 0.001). After discontinuation, only DC activation remained elevated at 6 months, whereas the other signs recovered. Conclusions The first week of CL wear was the main period for the appearance of ocular surface clinical signs, and the first month was the main period for the activation of subclinical inflammation. Corneal staining and conjunctival microvascular response are the main factors affecting CLD. Even if the clinical signs recover after discontinuing wear, subclinical inflammation may persist.
Collapse
Affiliation(s)
- Yangyang Xu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Zhiqiang Xu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Xupeng Shu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Qiaoli Liu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Yuzhou Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Jiahui Xia
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Yong Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
| | - Jia Qu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- *Correspondence: Liang Hu
| | - Liang Hu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, China
- Jia Qu
| |
Collapse
|
8
|
Walsh K, Jones L, Moody K. Addressing common myths and misconceptions in soft contact lens practice. Clin Exp Optom 2021; 105:459-473. [PMID: 34886744 DOI: 10.1080/08164622.2021.2003693] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Advances in contact lens technology over the past 50 years since the commercialisation of the first soft lenses in 1971 have been incredible, with significant changes in contact lens materials, frequency of replacement, care systems and lens designs occurring. However, despite the widespread availability of contact lenses, penetration rates for those who need vision correction remain in the low single digits and many practitioners seem to hold on to concepts around the potential value of contact lenses that appear based in the dim and distant past and are certainly no longer valid today. This review addresses 10 common 'myths and misconceptions' around soft contact lenses using an evidence-based approach that can hopefully dispel some of these incorrect assumptions.
Collapse
Affiliation(s)
- Karen Walsh
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, Canada.,Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Shatin, Hong Kong
| | - Kurt Moody
- Johnson & Johnson Vision, Jacksonville, Florida, USA
| |
Collapse
|
9
|
Fernández-Jimenez E, Diz-Arias E, Peral A. Improving ocular surface comfort in contact lens wearers. Cont Lens Anterior Eye 2021; 45:101544. [PMID: 34840071 DOI: 10.1016/j.clae.2021.101544] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 11/11/2021] [Accepted: 11/17/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE Contact lens discomfort (CLD) is a major concern that can lead to the decreased or abandoned use of contact lenses. Contact lens users with dry eye disease are more likely to present with CLD. This study was conducted to evaluate the efficacy of a bioprotective preservative free, hypotonic, 0.15% hyaluronic acid (HA)-3% Trehalose artificial tear in managing dry eye symptoms in contact lens wearers. METHODS A prospective, single-arm, observational pilot study to evaluate the effectiveness of treatment with HA-Trehalose artificial tears in contact lens wearers (N = 33) aged 18-45 years with symptoms of ocular discomfort. Participants used a preservative-free, hypotonic HA-Trehalose artificial tear (1 drop/4 times per day) for 84 days. Participants were assessed using Visual Analogue Scale (VAS) for dry eye symptoms (pain, photophobia, dry eye sensation, blurry vision, foreign body sensation, itching, tingling/burning, and sticky eye feeling), Ocular Surface Disease Index (OSDI), Contact Lens Dry Eye questionnaire (CLDEQ-8), Berkley Dry Eye Flow-Chart (DEFC) on Day 0 and Day 84 and tear break-up time (TBUT), ocular surface staining with fluorescein and lissamine green, tear meniscus evaluation, and visual acuity on Day 0, 35, and 84. RESULTS All VAS symptoms (except tingling/burning and sticky eye feeling), OSDI, CLEDQ-8, and DEFC showed statistically significant (p < 0.05) improvement from baseline (Day 0) to Day 84. Similarly, corneal (fluorescein) and conjunctival (lissamine green) quality improved during the study (p < 0.05 at Day 84 versus baseline). Tear break-up time (TBUT), conjunctival (lissamine green) staining, and tear meniscus decreased but the changes were not statistically significant. Visual acuity did not change during the study. There were no ocular or systemic adverse events. CONCLUSIONS This study showed that the instillation of a preservative-free, hypotonic, HA-Trehalose artificial tear in contact lenses wearers with dry eye syndrome significantly improved symptoms and reduced associated signs such as corneal and conjunctival staining.
Collapse
Affiliation(s)
| | - Elena Diz-Arias
- Faculty of Optics and Optometry, Universidad Complutense de Madrid, Spain
| | - Assumpta Peral
- Faculty of Optics and Optometry, Universidad Complutense de Madrid, Spain.
| |
Collapse
|
10
|
Martinez-Carrasco R, Argüeso P, Fini ME. Membrane-associated mucins of the human ocular surface in health and disease. Ocul Surf 2021; 21:313-330. [PMID: 33775913 PMCID: PMC8328898 DOI: 10.1016/j.jtos.2021.03.003] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 03/02/2021] [Accepted: 03/08/2021] [Indexed: 02/06/2023]
Abstract
Mucins are a family of high molecular weight, heavily-glycosylated proteins produced by wet epithelial tissues, including the ocular surface epithelia. Densely-packed O-linked glycan chains added post-translationally confer the biophysical properties of hydration, lubrication, anti-adhesion and repulsion. Membrane-associated mucins (MAMs) are the distinguishing components of the mucosal glycocalyx. At the ocular surface, MAMs maintain wetness, lubricate the blink, stabilize the tear film, and create a physical barrier to the outside world. In addition, it is increasingly appreciated that MAMs function as cell surface receptors that transduce information from the outside to the inside of the cell. Recently, our team published a comprehensive review/perspectives article for molecular scientists on ocular surface MAMs, including previously unpublished data and analyses on two new genes MUC21 and MUC22, as well as new MAM functions and biological roles, comparing human and mouse (PMID: 31493487). The current article is a refocus for the audience of The Ocular Surface. First, we update the gene and protein information in a more concise form, and include a new section on glycosylation. Next, we discuss biological roles, with some new sections and further updating from our previous review. Finally, we provide a new chapter on MAM involvement in ocular surface disease. We end this with discussion of an emerging mechanism responsible for damage to the epithelia and their mucosal glycocalyces: the unfolded protein response (UPR). The UPR offers a novel target for therapeutic intervention.
Collapse
Affiliation(s)
- Rafael Martinez-Carrasco
- Department of Ophthalmology, Tufts University School of Medicine at New England Eye Center, Tufts Medical Center, Boston, MA, 02111, USA.
| | - Pablo Argüeso
- Department of Ophthalmology, Harvard Medical School at Schepens Eye Research Institute of Mass, Eye and Ear, Boston, MA, 02114, USA.
| | - M Elizabeth Fini
- Department of Ophthalmology, Tufts University School of Medicine at New England Eye Center, Tufts Medical Center: Program in Pharmacology & Drug Development, Graduate School of Biomedical Sciences, Tufts University, Boston, MA, O2111, USA.
| |
Collapse
|
11
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
12
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
13
|
Downie LE, Bandlitz S, Bergmanson JPG, Craig JP, Dutta D, Maldonado-Codina C, Ngo W, Siddireddy JS, Wolffsohn JS. CLEAR - Anatomy and physiology of the anterior eye. Cont Lens Anterior Eye 2021; 44:132-156. [PMID: 33775375 DOI: 10.1016/j.clae.2021.02.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 02/06/2023]
Abstract
A key element of contact lens practice involves clinical evaluation of anterior eye health, including the cornea and limbus, conjunctiva and sclera, eyelids and eyelashes, lacrimal system and tear film. This report reviews the fundamental anatomy and physiology of these structures, including the vascular supply, venous drainage, lymphatic drainage, sensory innervation, physiology and function. This is the foundation for considering the potential interactions with, and effects of, contact lens wear on the anterior eye. This information is not consistently published as academic research and this report provides a synthesis from all available sources. With respect to terminology, the report aims to promote the consistent use of nomenclature in the field, and generally adopts anatomical terms recommended by the Federative Committee for Anatomical Terminology. Techniques for the examination of the ocular surface are also discussed.
Collapse
Affiliation(s)
- Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Australia.
| | - Stefan Bandlitz
- Höhere Fachschule für Augenoptik Köln, Cologne School of Optometry, Germany; School of Optometry, Aston University, Birmingham, UK
| | - Jan P G Bergmanson
- Texas Eye Research and Technology Center, University of Houston College of Optometry, United States
| | - Jennifer P Craig
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Debarun Dutta
- School of Optometry, Aston University, Birmingham, UK
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, UK
| | - William Ngo
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 14W Hong Kong Science Park, Hong Kong
| | | | - James S Wolffsohn
- School of Optometry, Aston University, Birmingham, UK; Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| |
Collapse
|
14
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
15
|
Arroyo-Del Arroyo C, Novo-Diez A, Blanco-Vázquez M, Fernández I, López-Miguel A, González-García MJ. Does placebo effect exist in contact lens discomfort management? Cont Lens Anterior Eye 2020; 44:101370. [PMID: 33071184 DOI: 10.1016/j.clae.2020.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/18/2020] [Accepted: 09/28/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To study the effect of daily disposable contact lens (DDCL) refitting in monthly contact lens (CL) wearers suffering from contact lens discomfort (CLD), and to assess if there is a placebo effect associated with this CLD intervention. METHODS Symptomatic CL wearers, according to the Contact Lens Dry Eye Questionnaire 8 (CLDEQ-8 ≥ 12 points), were divided into two groups. The study group was provided with DDCLs (delefilcon A) and the control group with a masked pair of their habitual monthly CLs (placebo effect) and were assessed after one month. Then, the control group was provided with the same DDCLs and evaluated one month later. The symptoms were recorded with the CLDEQ-8 and global rating of change scale (GRCS). Non-invasive tear break-up time (NITBUT), conjunctival hyperaemia, fluorescein staining, and lid wiper epitheliopathy (LWE) were evaluated. Changes between visits, groups, and the effect of each intervention were analysed. RESULTS Thirty-one participants (mean age: 23.2 ± 5.3 years) were recruited. The study group (n = 14) showed an improvement of -39.6 ± 25.8 % (p < 0.001) in CLDEQ-8 and 31.3 ± 14.6 points in GRCS (p < 0.001) after one month of DDCL use, while no changes in clinical tests were found. In the control group (n = 17), symptoms improved significantly after wearing the masked monthly CL (CLDEQ-8: -26.1 ± 31.0 %, p = 0.03; GRCS: 14.9 ± 17.0, p = 0.002), however a worsening in bulbar (26.5 ± 40.0 %; p = 0.02) and limbal hyperaemia (21.6 ± 34.7 %, p = 0.02) and an improvement of -19.1 ± 37.0 % (p = 0.049) in LWE was found. When the control group was fitted with the DDCL, improvements in GRCS (20.5 ± 25.5, p = 0.02), NITBUT (37.9 ± 42.3 %, p = 0.002), and conjunctival staining (-47.1 ± 59.9 %, p = 0.005) were noted. CONCLUSIONS Refitting symptomatic monthly CL wearers with Delefilcon A DDCL is effective in reducing symptoms related to CLD. However, clinicians and researchers must be aware of the existence of a placebo effect when assessing the effectiveness of any CL refitting.
Collapse
Affiliation(s)
- Cristina Arroyo-Del Arroyo
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain
| | - Andrea Novo-Diez
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain
| | - Marta Blanco-Vázquez
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
| | - Itziar Fernández
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| | - Alberto López-Miguel
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Redes temáticas de investigación cooperativa en salud (Oftared), Instituto de Salud Carlos III, Madrid, Spain.
| | - María Jesús González-García
- Instituto Universitario de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain; Departamento de Física Teórica, Atómica y Óptica, Universidad de Valladolid, Valladolid, Spain; Networking Research Center on Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Valladolid, Spain
| |
Collapse
|
16
|
Montani G, Martino M. Tear Film Characteristics During Wear of Daily Disposable Contact Lenses. Clin Ophthalmol 2020; 14:1521-1531. [PMID: 32581509 PMCID: PMC7279739 DOI: 10.2147/opth.s242422] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 04/23/2020] [Indexed: 01/30/2023] Open
Abstract
Purpose To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV). Patients and Methods Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after ≥8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink. Results TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times. Conclusion While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.
Collapse
Affiliation(s)
- Giancarlo Montani
- Dipartimento di Matematica e Fisica "Ennio De Giorgi", CERCA Università del Salento, Lecce, Italy
| | - Maurizio Martino
- Dipartimento di Matematica e Fisica "Ennio De Giorgi", CERCA Università del Salento, Lecce, Italy
| |
Collapse
|
17
|
Tavazzi S, Origgi R, Anselmi M, Corvino A, Colciago S, Fagnola M, Bracco S, Zeri F. Effects of Aqueous-Supplementing Artificial Tears in Wearers of Biweekly Replacement Contact Lenses vs Wearers of Daily Disposable Contact Lenses. CLINICAL OPTOMETRY 2020; 12:75-84. [PMID: 32612403 PMCID: PMC7323791 DOI: 10.2147/opto.s249078] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 05/07/2020] [Indexed: 06/11/2023]
Abstract
PURPOSE To compare the effects of artificial tears (ATs) in wearers of biweekly replacement silicone hydrogel contact lenses (BW-Ws) and wearers of daily disposable contact lenses (DD-Ws) of the same material. MATERIALS AND METHODS The aqueous-supplementing ATs, OPTOyalA and OPTOidro, were assigned to be used for 2 weeks to healthy and young subjects: 1) 20 (8 and 12, respectively) BW-Ws wearing silicone hydrogel somofilcon A CLs (Clariti Elite), 2) 18 (9 and 9, respectively) DD-Ws wearing silicone hydrogel somofilcon A CLs (Clarity 1 Day), and 3) a control group of 33 (16 and 17, respectively) N-Ws. Ocular symptoms and comfort, tear volume and stability, and ocular surface condition were assessed by Ocular Surface Disease Index (OSDI), 5-Item Dry Eye Questionnaire (DEQ5), tear meniscus height (TMH), non-invasive tear break-up time (NIBUT), and evaluation of ocular redness (OR). The assessment was performed before and after 15 days of use of the ATs in the 3 groups (BW-Ws, DD-Ws, and N-Ws). RESULTS No clear significant difference was noted in symptoms and signs between OPTOyalA and OPTOidro irrespectively of the group of people studied. ATs use for 15 days produced a significant improvement in DEQ5 and OR in DD-Ws (Δ=-34%, p=0.006; Δ=-23%, p<0.001) and in N-Ws (Δ=-21%, p=0.001; Δ=-10%, p=0.006) but not in BW-Ws (Δ=-5%, p=0.072; Δ=-2%, p=0.257). No significant change was noted for TMH. CONCLUSION In young and healthy subjects, the aqueous-supplementing effect of the ATs under consideration is more a rinsing and tear replacem ent effect than an increase in tear volume, and it produces an improvement of the eye redness and ocular symptoms. Contact lens wear influenced the effectiveness of ATs in a way which is correlated with the CL replacement schedule.
Collapse
Affiliation(s)
- Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
- Research Centre in Optics and Optometry (COMiB), University of Milano-Bicocca, Milan, Italy
| | - Riccardo Origgi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | - Martina Anselmi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | - Andrea Corvino
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | - Sara Colciago
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | - Matteo Fagnola
- Research Centre in Optics and Optometry (COMiB), University of Milano-Bicocca, Milan, Italy
| | - Silvia Bracco
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | - Fabrizio Zeri
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
- Research Centre in Optics and Optometry (COMiB), University of Milano-Bicocca, Milan, Italy
- Ophthalmic Research Group, School of Life and Health Sciences, Aston University, Birmingham, UK
| |
Collapse
|
18
|
Gu T, Zhao L, Liu Z, Zhao S, Nian H, Wei R. Evaluation of tear film and the morphological changes of meibomian glands in young Asian soft contact lens wearers and non-wearers. BMC Ophthalmol 2020; 20:84. [PMID: 32131774 PMCID: PMC7057503 DOI: 10.1186/s12886-020-1328-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 01/23/2020] [Indexed: 01/26/2023] Open
Abstract
Background The aim of this study was to explore the differences in terms of tear film and meibomian glands (MGs) between young Asian soft contact lens (CL) wearers and non-wearers. Methods A prospective, cross-sectional observational study was conducted using 148 subjects (63 non-wearers, and 85 soft CL wearers who had been wearing CLs for more than 1 year) recruited from a clinic in Tianjin, China. All subjects first responded to an Ocular Surface Disease Index (OSDI) questionnaire and then underwent a standardized dry eye examination, which included measuring tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and corneal fluorescein staining (CFS). The MGs were evaluated via ImageJ, distorted MG count and the MG dropout were recorded. Results Compared to the control group (non-wearers), the CL group recorded higher OSDI and CFS scores, lower TMH and NITBUT values, a larger distorted MG count, and larger MG dropout (all P < 0.05). Pearson correlation analysis found a correlation between MG dropout and the duration of CL use (r = 0.440, P < 0.001), OSDI (r = 0.298, P = 0.006), and CFS scores (r = 0.442, P < 0.001). Conclusion CL wearers showed higher MG dropout and reduced TMH and NITBUT, which likely contributes to severe CL-related dry eye symptoms. CL use may lead to a higher MG dropout rate, and the extent of the MG dropout presumably influences the tear film status in CL wearers.
Collapse
Affiliation(s)
- Tianpu Gu
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China.,Eye Institute and School of Optometry, Tianjin, 300384, China.,Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Lu Zhao
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China.,Eye Institute and School of Optometry, Tianjin, 300384, China.,Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Zhuzhu Liu
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China.,Eye Institute and School of Optometry, Tianjin, 300384, China.,Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Shaozhen Zhao
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China.,Eye Institute and School of Optometry, Tianjin, 300384, China.,Tianjin Medical University Eye Hospital, Tianjin, 300384, China
| | - Hong Nian
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China. .,Eye Institute and School of Optometry, Tianjin, 300384, China. .,Tianjin Medical University Eye Hospital, Tianjin, 300384, China.
| | - Ruihua Wei
- Tianjin Key Laboratory of Retinal Functions and Disease, Tianjin, 300384, China. .,Eye Institute and School of Optometry, Tianjin, 300384, China. .,Tianjin Medical University Eye Hospital, Tianjin, 300384, China.
| |
Collapse
|
19
|
Colciago S, Picarazzi S, Lecchi M, D'Arienzo M, Tavazzi S, Zeri F. Zeta potential of tear samples: A tool to explore the effects of wear of contact lenses. Cont Lens Anterior Eye 2019; 42:487-491. [PMID: 31519352 DOI: 10.1016/j.clae.2019.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2018] [Revised: 06/14/2019] [Accepted: 06/17/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE The aim was to develop a method to assess the electrostatic properties of human tear samples, and to evaluate their modifications induced by the wear of contact lenses (CLs). METHOD The barrier method was developed for the measurement of the isoelectric point (IEP) on relatively small quantities. The method was applied to compare three groups: tears (TNW) of non-wearers, tears (TW_etaf) of regular wearers of etafilcon A CLs, and tears (TW_omaf) of regular wearers of omafilcon A CLs. Zeta potential (ζ) as a function of pH was measured by a Zetasizer Nano ZS90 (Malvern Instruments) on 40%-diluted samples, obtained by mixing 57 μL of tears of different subjects of the same group with 85 μL of HCl aqueous solution. IEP was deduced as the pH at which ζ is zero, i.e. the net electric charge on tear constituents being neutralized. RESULTS Within an error of about 0.05, IEPs were found to be 2.90 (TNW), 2.80 (TW_omaf), and 3.16 (TW_etaf). On average, a lower H+ concentration is needed to neutralize the surface charge of the tear components of etafilcon A wearers, compared to both TNW and TW_omaf. CONCLUSION IEP measurements on tear samples of wearers of different types of CLs are proposed in order to enhance the knowledge on the modifications of the profile of charged species in tears. The TW_etaf results, compared to those of the other groups, are compatible with an increase, due to the wear of etafilcon A CLs, of the relative concentration of high-IEP proteins.
Collapse
Affiliation(s)
- Sara Colciago
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy
| | - Sara Picarazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy
| | - Marzia Lecchi
- University of Milano Bicocca, Department of Biotechnology and Bioscience, Piazza della Scienza 2, I-20126 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy
| | - Massimiliano D'Arienzo
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy.
| | - Fabrizio Zeri
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Centre, via R. Cozzi 55, I-20125 Milan, Italy; School of Life & Health Sciences, Aston University, Aston Triangle, Birmingham, B4 7ET, UK
| |
Collapse
|
20
|
Effects of Blink Rate on Tear Film Optical Quality Dynamics with Different Soft Contact Lenses. J Ophthalmol 2019; 2019:4921538. [PMID: 31360543 PMCID: PMC6652047 DOI: 10.1155/2019/4921538] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 05/27/2019] [Accepted: 06/10/2019] [Indexed: 12/12/2022] Open
Abstract
Objective The aim of this study was to investigate tear film optical quality dynamics for four types of silicone hydrogel contact lenses (SHCLs) for daily wear over a 15-day period and for different blink rate (BR) patterns. Methods A prospective randomized, double-blind, cross-over pilot study including four SHCLs (A: lotrafilcon B (Air Optix plus HydraGlyde, Alcon Laboratories); B: samfilcon A (Ultra, Bausch & Lomb); C: comfilcon A (Biofinity, CooperVision); and D: filcom V3 (Blu:gen, Mark'Ennovy)). Serial measurements of Objective Scatter Index (OSI) using the HD Analyzer (Visiometrics S.L., Terrassa, Spain) were taken at different blinking patterns: blinking every 2.5 seconds (high BRs) and every 9 seconds (low BRs). They were performed during the first visit before CL insertion (baseline), after 20 minutes of CL wear (Day 1), and during the last visit after 8 hours of CL wear on day 15 of use (Day 15). Results Normal young healthy subjects were recruited and fitted with the four lenses. For low BRs, the mean OSI value increased over time for all CLs and the slope of the curve also increased for all CLs, except for CL D. However, for high BRs, the mean OSI value increased only for CLs B and C and the slope of the curve did not change over time for any of them. Conclusions These results suggest that the tear film optical quality dynamics after wearing SCHLs for 15 days seems to undergo a slight deterioration only for lowest BR.
Collapse
|
21
|
Lee JW, Cho HG, Moon BY, Kim SY, Yu DS. Effects of prolonged continuous computer gaming on physical and ocular symptoms and binocular vision functions in young healthy individuals. PeerJ 2019; 7:e7050. [PMID: 31198647 PMCID: PMC6555390 DOI: 10.7717/peerj.7050] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 05/01/2019] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND AND OBJECTIVE Addiction to computer gaming has become a social problem in Korea and elsewhere, and it has been enlisted as a mental health disorder by the World Health Organization. Most studies related to computer use and vision have individually assessed physical and ocular symptoms and binocular vision. Accordingly, the present study comprehensively assessed subjective physical and ocular symptoms and functions related to binocular vision after prolonged continuous computer gaming. This study aimed to investigate the effects of prolonged continuous computer gaming on physical and ocular health and visual functions in young healthy individuals. METHODS Fifty healthy college students (35 male/15 female), aged 19-35 years old, were enrolled in this study. The inclusion criteria were no binocular vision problems and no reported history of ocular disease. Participants played continuously for 4 h from 6:00 to 10:00 p.m. Physical and ocular symptoms and visual functions such as convergence, accommodation, phoria, and the blink rate were assessed before and after continuous computer gaming for 4 h. RESULTS Continuous computer gaming for 4 h resulted in convergence and accommodation disturbances and increased physical and ocular discomfort. Near phoria showed an exophoric shift, whereas distance phoria showed no change. Moreover, the accommodative and vergence facilities and blink rate were significantly decreased. All visual functions recovered to the baseline levels by the following morning. DISCUSSION Our findings suggest that excessive and continuous computer gaming impairs visual functions and causes ocular and physical fatigue. Our findings further the understanding of the adverse effects of excessive computer use on physical and ocular health, and adequate breaks are necessary to reduce physical and visual discomfort during computer gaming.
Collapse
Affiliation(s)
- Ji-Woo Lee
- Department of Optometry and Vision Science, Kyungwoon University, Gumi, South Korea
| | - Hyun Gug Cho
- Department of Optometry, Kangwon National University, Samcheok, South Korea
| | - Byeong-Yeon Moon
- Department of Optometry, Kangwon National University, Samcheok, South Korea
| | - Sang-Yeob Kim
- Department of Optometry, Kangwon National University, Samcheok, South Korea
| | - Dong-Sik Yu
- Department of Optometry, Kangwon National University, Samcheok, South Korea
| |
Collapse
|
22
|
Downie LE, Gad A, Wong CY, Gray JHV, Zeng W, Jackson DC, Vingrys AJ. Modulating Contact Lens Discomfort With Anti-Inflammatory Approaches: A Randomized Controlled Trial. Invest Ophthalmol Vis Sci 2019; 59:3755-3766. [PMID: 30046817 DOI: 10.1167/iovs.18-24758] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To assess the efficacy of anti-inflammatory approaches, comprising a topical corticosteroid and omega-3 supplements, for modulating the inflammatory overlay associated with contact lens discomfort (CLD). Methods This randomized controlled trial involved 72 adults with CLD, randomized (1:1:1:1) to one of the following: placebo (oral olive oil), oral fish oil (900 mg/d eicosapentaenoic acid [EPA] + 600 mg/d docosohexaenoic acid [DHA]), oral combined fish+flaxseed oils (900 mg/d EPA + 600 mg/d DHA + 900 mg/d alpha-linolenic acid), or omega-3 eye-drops (0.025% EPA + 0.0025% DHA four times per day [qid]) for 12 weeks, with visits at baseline, weeks 4 and 12. At week 12, participants who received placebo were assigned a low-potency corticosteroid (fluorometholone [FML] 0.1%, drops, three times per day [tid]) for 2 weeks (week 14). Results Sixty-five participants completed the primary endpoint. At week 12, contact lens dry-eye questionnaire (CLDEQ-8) score was reduced from baseline with oral fish oil (-7.3 ± 0.8 units, n = 17, P < 0.05), compared with placebo (-3.5 ± 0.9 units, n = 16). FML produced significant reductions in tear IL-17A (-71.1 ± 14.3%, n = 12) and IL-6 (-47.6 ± 17.5%, n = 12, P < 0.05) relative to its baseline (week 12). At week 12, tear IL-17A levels were reduced from baseline in the oral fish oil (-63.2 ± 12.8%, n = 12, P < 0.05) and topical omega-3 (-76.2 ± 10.8%, n = 10, P < 0.05) groups, compared with placebo (-3.8 ± 12.7%, n = 12). Tear IL-6 was reduced with all omega-3 interventions, relative to placebo (P < 0.05) at week 12. Conclusions CLD was attenuated by oral long-chain omega-3 supplementation for 12 weeks. Acute (2 week) topical corticosteroids and longer-term (12 week) omega-3 supplementation reduced tear levels of the proinflammatory cytokines IL-17A and IL-6, demonstrating parallels in modulating ocular inflammation with these approaches.
Collapse
Affiliation(s)
- Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| | - Anne Gad
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| | - Chinn Yi Wong
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, Australia
| | - John Henry V Gray
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, Australia
| | - Weiguang Zeng
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, Australia
| | - David C Jackson
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, Australia
| | - Algis J Vingrys
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
23
|
Eftimov P, Yokoi N, Peev N, Georgiev GA. Impact of Air Exposure Time on the Water Contact Angles of Daily Disposable Silicone Hydrogels. Int J Mol Sci 2019; 20:ijms20061313. [PMID: 30875896 PMCID: PMC6471927 DOI: 10.3390/ijms20061313] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 03/05/2019] [Accepted: 03/07/2019] [Indexed: 01/17/2023] Open
Abstract
The wettability of silicone hydrogel (SiHy) contact lens (CLs) is crucial for the pre-lens tear film stability throughout the day. Therefore, sessile drop and captive bubble setups were used to study the advancing and receding water contact angles (CA) of four SiHy materials: narafilcon A (TE), senofilcon A (AOD), stenfilcon A (MD), and delefilcon A (DT). TE and AOD have 48% and 38% water content, respectively, and no surface coating. MD (54% water) implements "smart chemistry" with just 4.4% bulk silicone content, while DT has >80% water at its surface. These SiHy were subjected to continuous blink-like air exposure (10 s)/rehydration (1s) cycles for 0, 1, 2, 3, 4, 6, 8, 10, 12, 14, and 16 h. The advancing CA, which measures the rehydration propensity of the CL surface, proved to be the most sensitive parameter to discriminate between the samples. The order of performance for the entire time scale was DT > MD >> AOD ≥ TE. The extended desiccation/rehydration cycling increased the differences between the CA of DT and MD compared to AOD and TE. This suggests that the low Si surface content and the high surface hydration are major determinants of SiHy wettability.
Collapse
Affiliation(s)
- Petar Eftimov
- Department of Cytology, Histology and Embryology, Faculty of Biology, St. Kliment Ohridski University of Sofia, Sofia 1164, Bulgaria.
| | - Norihiko Yokoi
- Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto 602-8566, Japan.
| | - Nikola Peev
- Department of Optics and Spectroscopy, Faculty of Physics, St. Kliment Ohridski University of Sofia, Sofia 1164, Bulgaria.
| | - Georgi As Georgiev
- Department of Optics and Spectroscopy, Faculty of Physics, St. Kliment Ohridski University of Sofia, Sofia 1164, Bulgaria.
| |
Collapse
|
24
|
Chrysouli M, Banti C, Milionis Ι, Koumasi D, Raptopoulou C, Psycharis V, Sainis I, Hadjikakou S. A water-soluble silver(I) formulation as an effective disinfectant of contact lenses cases. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 93:902-910. [DOI: 10.1016/j.msec.2018.08.061] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2018] [Revised: 07/28/2018] [Accepted: 08/30/2018] [Indexed: 01/22/2023]
|
25
|
Gad A, Vingrys AJ, Wong CY, Jackson DC, Downie LE. Tear film inflammatory cytokine upregulation in contact lens discomfort. Ocul Surf 2018; 17:89-97. [PMID: 30321605 DOI: 10.1016/j.jtos.2018.10.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 10/05/2018] [Accepted: 10/11/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE To investigate the ocular inflammatory response, using clinical and immunological techniques, in people experiencing contact lens (CL) discomfort. METHODS This study involved 38 adults who were full-time, silicone-hydrogel CL wearers. Participants were categorized into groups based upon a validated CL dry-eye questionnaire (CLDEQ-8) (n = 17 'asymptomatic', CLDEQ-8 score <9; n = 21 'symptomatic', CLDEQ-8 score ≥13). Examinations were performed at two visits (one with, and one without, CL wear), separated by one-week. Testing included: tear osmolarity, ocular redness, tear stability, ocular surface staining, meibography, tear production and tear collection. Tear osmolarity was taken from the inferior-lateral and superior-lateral menisci. The 'Inferior-Superior Osmotic Difference', I-SOD, was the absolute osmolarity difference between these menisci. Concentrations of seven cytokines (IL-2, IL-4, IL-6, IL-10, IL-17A, IFN-gamma, TNF-alpha) were assayed from basal tears using multiplex cytometric bead array. RESULTS At baseline, there was no significant difference in key clinical signs between asymptomatic and symptomatic CL wearers (p > 0.05). The I-SOD was greater in symptomatic than asymptomatic CL wearers (23.1 ± 2.6 versus 11.3 ± 1.4 mOsmol/L, p = 0.001). People experiencing CL discomfort had higher tear IL-17A (122.6 ± 23.7 versus 44.0 ± 10.0 pg/mL, p = 0.02) and reduced tear stability (6.3 ± 1.1 versus 10.4 ± 1.6 s, p = 0.03) after several hours of CL wear. Tear IL-17A levels correlated with both the I-SOD (r = 0.43, p = 0.01) and CLDEQ-8 score (r = 0.40, p = 0.01). CONCLUSIONS CL discomfort occurs in individuals having no clinical dry eye signs, and is associated with higher tear levels of the pro-inflammatory cytokine IL-17A. These findings support an association between the discomfort response and low-grade, ocular surface inflammation.
Collapse
Affiliation(s)
- Anne Gad
- Department of Optometry and Vision Sciences, Australia
| | | | - Chinn Yi Wong
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | - David Charles Jackson
- Department of Microbiology and Immunology at the Peter Doherty Institute of Infection and Immunity, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | | |
Collapse
|
26
|
Tseng RC, Chen CC, Hsu SM, Chuang HS. Contact-Lens Biosensors. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2651. [PMID: 30104496 PMCID: PMC6111605 DOI: 10.3390/s18082651] [Citation(s) in RCA: 62] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/06/2018] [Accepted: 08/10/2018] [Indexed: 12/14/2022]
Abstract
Rapid diagnosis and screening of diseases have become increasingly important in predictive and preventive medicine as they improve patient treatment strategies and reduce cost as well as burden on our healthcare system. In this regard, wearable devices are emerging as effective and reliable point-of-care diagnostics that can allow users to monitor their health at home. These wrist-worn, head-mounted, smart-textile, or smart-patches devices can offer valuable information on the conditions of patients as a non-invasive form of monitoring. However, they are significantly limited in monitoring physiological signals and biomechanics, and, mostly, rely on the physical attributes. Recently, developed wearable devices utilize body fluids, such as sweat, saliva, or skin interstitial fluid, and electrochemical interactions to allow continuous physiological condition and disease monitoring for users. Among them, tear fluid has been widely utilized in the investigation of ocular diseases, diabetes, and even cancers, because of its easy accessibility, lower complexity, and minimal invasiveness. By determining the concentration change of analytes within the tear fluid, it would be possible to identify disease progression and allow patient-oriented therapies. Considering the emerging trend of tear-based biosensing technology, this review article aims to focus on an overview of the tear fluid as a detection medium for certain diseases, such as ocular disorders, diabetes, and cancer. In addition, the rise and application of minimally invasive detection and monitoring via integrated contact lens biosensors will also be addressed, in regards to their practicality and current developmental progress.
Collapse
Affiliation(s)
- Ryan Chang Tseng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Ching-Chuen Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Sheng-Min Hsu
- Department of Ophthalmology, National Cheng Kung University Hospital, Tainan City 704, Taiwan.
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
- Medical Device Innovation Center, National Cheng Kung University, Tainan City 701, Taiwan.
| |
Collapse
|