Ertuğrul İF, Arslan HK. Investigation of four nickel titanium endodontic instruments, with cyclic fatigue resistance, scanning electron microscopy, and energy dispersive x-ray spectroscopy. Microsc Res Tech 2024. [PMID: 38988203 DOI: 10.1002/jemt.24655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 06/11/2024] [Accepted: 07/01/2024] [Indexed: 07/12/2024]
Abstract
The aim of this study was to compare of four different nickel-titanium (Ni-Ti) endodontic files and evaluate in terms of cyclic fatigue resistance and metallurgical properties. Four different type Ni-Ti root canal files Protaper Next X2 (PTN) (Dentsply Maillefer, Ballaigues, Switzerland), One Curve (OC) #25.06 (Micro Mega, Besancon, France), EndoPlus Flex Plus Gold X2 (EPG) (Turkuaz Dental, Denizli, Turkey), and EndoPlus Flex Plus Blue #25.06 (EPB) (Turkuaz Dental, Denizli, Turkey) files were tested for cyclic fatigue resistance (n = 20). During experiments artificial zirconia block canal was used. The artificial canal designed with curvature 60° and 5-mm radius. The number of cyclic to fracture (NCF) was noted. Fractured length (FL) parts of Ni-Ti files were recorded to assessment of fracture volumetric point. All fractured surfaces of Ni-Ti files were assessed by scanning electron microscope (SEM) to confirm the type of fractures. Descriptive evaluation become accomplished for the fundamental composition of units with the aid of using energy-dispersive x-ray spectroscopy (EDX). NCF data were evaluated via Bonferroni test with post hoc multiple comparison method. OC showed the highest NCF values (p < .05). The standardization of the study was confirmed as the FL of files was statistically similar in length (p > .05). SEM analysis confirmed that all scanned samples were fractured due to cyclic fatigue. EDX analysis confirmed that EPB established the poorest Ni content file. RESEARCH HIGHLIGHTS: The cyclic fatigue-related failure of One Curve was significantly more resistant than Protaper Next and EndoPlus files. Scanning electron microscopy images showed that One Curve and Protaper Next have round tips Energy dispersive x-ray spectroscopy showed that all four endodontic instruments mainly have Nickel and Titanium elements.
Collapse
Affiliation(s)
- İhsan Furkan Ertuğrul
- Department of Endodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| | - Havva Kübra Arslan
- Department of Endodontics, Faculty of Dentistry, Pamukkale University, Denizli, Turkey
| |
Collapse
|
2
|
Allahem Z, Bendahmash M, Almeaither R, Alfawaz H, Alqedairi A. Evaluation of cyclic fatigue behavior of RACE EVO rotary Files: In-vitro comparative study. Saudi Dent J 2024; 36:656-660. [PMID: 38690374 PMCID: PMC11056425 DOI: 10.1016/j.sdentj.2024.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 03/11/2024] [Accepted: 03/11/2024] [Indexed: 05/02/2024] Open
Abstract
Introduction Comparative evaluation of the newly introduced; RACE EVO file system to the currently well-performing file systems like HyFlex EDM OneFile, Vortex Blue, ProTaper Gold (PTG) with regards to the cyclic fatigue resistance. Materials &Methods.The endodontic rotary files under evaluation were segregated into four groups as follows:; RACE EVO, PTG, Vortex Blue, and HyFlex EDM OneFile. A detailed physical analysis of the cyclic fatigue resistance was performed in 15 files of each type (n = 60). Under the test conditions of 37 °C the test samples were subjected to continuous motion at the manufacturer recommended speed within an artificial curved canal until it fractured. For all the test samples, with the recording of time of fracture, calculation was done for number of cycles to fracture (NCF). In addition, the length of the fractured segment was determined. The fractured surface was further evaluated with scanning electron microscopic (SEM) images. Results Highest significance for NCF was seen in HyFlex EDM OneFile followed by the Vortex Blue, PTG, and; RACE EVO (p < 0.05) by analyzing the data statistically. Significant differences among the lengths of the fractured segments were evident among tested files, ranging between 4.73 and 6.3 mm (p < 0.05) with HyFlex EDM OneFile uniquely differentiating from the others showing the fracture at 6.3 mm. The common features of cyclic fatigue failure was further substantiated by SEM images. Conclusions Compared to the HyFlex EDM OneFile, Vortex Blue, and PTG files; RACE EVO demonstrated significantly lower resistance to cyclic fatigue.
Collapse
Affiliation(s)
- Ziyad Allahem
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Mohammad Bendahmash
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Reem Almeaither
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Hussam Alfawaz
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Abdullah Alqedairi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Langaliya A, Patel N, Pallipurath A, Parmar G, Kothari A, Jhala K. Analysis of cyclic fatigue resistance of different endodontic nickel-titanium rotary instruments: An in vitro study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:95-99. [PMID: 38389747 PMCID: PMC10880468 DOI: 10.4103/jcde.jcde_204_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 11/10/2023] [Accepted: 12/06/2023] [Indexed: 02/24/2024]
Abstract
Aims The aim of this in vitro study was to compare the cyclic fatigue resistance of three different endodontic nickel-titanium rotary instruments using a dynamic testing device. Materials and Methods Ten files each of ProTaper Gold (PG), Hyflex Electro-discharge Machining (HEDM), and TruNatomy (TN) were tested in a custom-fabricated dynamic cyclic fatigue testing device at 60° curvature having a radius of curvature of 5 mm. The number of cycles to the fracture (NCF) of each instrument was calculated and three continuous groups were compared by the Kruskal-Wallis test and Dunn post hoc test was used for pairwise comparison. Results Cyclic fatigue resistance of HEDM was the highest, followed by TN. PG had the lowest among the three. Conclusion Within the limitations of the present in vitro results, it can be concluded that HEDM files appeared to be suitable for shaping complex canals with the greater number of cycles before it fractures.
Collapse
Affiliation(s)
- Akshayraj Langaliya
- Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Neeta Patel
- Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Athulya Pallipurath
- Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Girish Parmar
- Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Anjali Kothari
- Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India
| | - Kairavi Jhala
- Department of Conservative Dentistry and Endodontics, AMC Dental College and Hospital, Ahmedabad, Gujarat, India
| |
Collapse
|
4
|
Yi Ği T Eİ, Çetinkaya İ. Effect of Temperature on the Cyclic Fatigue Resistance and Phase Transformation Behavior of Three Different NiTi Endodontic Instruments. Cureus 2024; 16:e52916. [PMID: 38406139 PMCID: PMC10893821 DOI: 10.7759/cureus.52916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/22/2024] [Indexed: 02/27/2024] Open
Abstract
Background This study aims to analyze the phase transformation behavior and evaluate the effect of different temperatures on the fracture strength of files. Methodology A total of 108 files were used, and cyclic fatigue tests were performed on HyFlex EDM, VDW.ROTATE, and TruNatomy at three different temperatures (+4°C, +35°C, and +60°C) The time to fracture of files was measured, and the number of cycles was calculated. In addition, the fractured fragment lengths were measured. The Kruskal-Wallis test was used to compare the data that were not normally distributed according to groups. The Mann-Whitney U test was performed for comparisons. P-values <0.05 were considered statistically significant. Results As the temperature increased for all files, the number of cycles to fracture (NCF) decreased. NCF was significantly higher for ROTATE at 4°C and 60°C and HyFlex EDM at 35°C. Conclusions The resistance to cyclic fatigue in all files decreased significantly as the temperature increased.
Collapse
|
5
|
Awati AS, Dhaded NS, Mokal S, Doddwad PK. Analysis of the depth of penetration of an epoxy resin-based sealer following a final rinse of irrigants and use of activation systems: An in vitro study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:87-94. [PMID: 38389742 PMCID: PMC10880483 DOI: 10.4103/jcde.jcde_221_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 11/02/2023] [Accepted: 11/06/2023] [Indexed: 02/24/2024]
Abstract
Objective The objective of the study was to compare and evaluate the depth of penetration of an epoxy resin-based sealer following a final rinse of 17% ethylenediaminetetraacetic acid (EDTA) and 18% 1-hydroxyethylidene 1, 1-diphosphonate (HEDP), with diode laser and passive ultrasonic activation (PUI): an in vitro confocal laser scanning microscopy study. Materials and Methods Fifty-two extracted human mandibular premolar teeth with single root and single canal were selected. They were disinfected in 0.1% thymol solution, cleaned of calculus and soft tissues, and stored in 0.1% thymol solution till use. All teeth were radiographed and selected as per the inclusion and exclusion criteria. The teeth were decoronated using a diamond disk under copious water spray to acquire a standardized root length of 14 mm. Working length was established by inserting a size 10-K file into each root canal until it is visible at the apical foramen and by subtracting 1 mm from the recorded length. Instrumentation of the root canal was done till master apical file size of F3 using ProTaper universal, rotary instruments. The canals were irrigated with 2 mL of 3% sodium hypochlorite between successive files. Teeth were randomly divided into four subgroups n = 12 according to the intervention. Passive ultrasonic irrigation and diode laser were used to activate the irrigants. Final irrigation was performed with distilled water. These specimens were examined using confocal laser scanning microscope (OLYMPUS FLUOVIEW FV 3000) for dentinal tubule penetration of the sealer. Two-way ANOVA test and Tukey's multiple post hoc test were used for statistical analysis. Results Highly significant difference was seen between the groups with EDTA and HEDP, with HEDP demonstrating the highest penetration. Among the activation techniques used in this study, PUI showed the highest penetration of the sealer. The least penetration was seen with diode laser activation and EDTA. Conclusions The irrigation activation techniques significantly influence the penetration of sealer into root dentinal tubules. When penetration of sealer with different irrigation techniques and irrigants was evaluated, significant greater level of sealer penetration was attained with PUI activation of HEDP.
Collapse
Affiliation(s)
- Aishwarya Sanjay Awati
- Department of Conservative Dentistry and Endodontics, KLE VK Institute of Dental Sciences, Belagavi, Karnataka, India
| | - Neha S. Dhaded
- Department of Conservative Dentistry and Endodontics, KLE VK Institute of Dental Sciences, Belagavi, Karnataka, India
| | - Siddhesh Mokal
- Department of Conservative Dentistry and Endodontics, KLE VK Institute of Dental Sciences, Belagavi, Karnataka, India
| | - Preeti Kore Doddwad
- Department of Conservative Dentistry and Endodontics, KLE VK Institute of Dental Sciences, Belagavi, Karnataka, India
| |
Collapse
|
6
|
Grande NM, Castagnola R, Minciacchi I, Marigo L, Plotino G. A review of the latest developments in rotary NiTi technology and root canal preparation. Aust Dent J 2023; 68 Suppl 1:S24-S38. [PMID: 37960998 DOI: 10.1111/adj.12998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/18/2023] [Indexed: 11/15/2023]
Abstract
The introduction of nickel-titanium (NiTi) mechanical instruments dramatically changed clinical endodontics over the last few decades. Before NiTi, it was necessary to use more instruments to create an ideal root canal shape, and many approaches, sequences and techniques were developed over the years. Recently, NiTi endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments to improve their root canal preparation outcomes and reduce associated canal preparation risks during root canal treatment. Heat treatment is one of the most fundamental approaches to improving the fatigue resistance and flexibility of NiTi endodontic instruments. In addition, new kinematics have been developed to offer greater safety and efficiency. This narrative review describes the general properties and manufacturing of NiTi instruments, and the mechanical system evolution of NiTi instruments.
Collapse
Affiliation(s)
- N M Grande
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | - R Castagnola
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
| | | | - L Marigo
- Dipartimento di Testa-Collo e organi di senso, Università Cattolica del Sacro Cuore, Rome, Italy
- UOC Odontoiatria Generale e Ortodonzia, Dipartimento Scienze dell'Invecchiamento, Neurologiche, Ortopediche e della Testa-Collo. Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | | |
Collapse
|
7
|
Kermeoglu F, Abduljalil M. Impacts of NaOCl and Irritrol irrigation solutions with/without autoclave sterilisation on the cyclic fatigue resistance of different nickel-titanium files. AUST ENDOD J 2022; 48:392-399. [PMID: 34617638 DOI: 10.1111/aej.12580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 08/22/2021] [Accepted: 09/26/2021] [Indexed: 12/14/2022]
Abstract
This research aimed to examine the impact of NaOCl and Irritrol solutions with/without autoclave sterilisation on the cyclic fatigue resistance of ProTaper, WaveOne Gold and Reciproc NiTi files. Seventy files in every group were separated into seven subgroups (n = 10) according to irrigation solutions and sterilisation procedures. The mean and standard deviations of the time to fracture was calculated for each group, and the data statistical analysis was performed (P ≤ 0.05). Significantly higher cyclic fatigue resistance was found in Reciproc files than the other types of files. The differences between the control and other subgroups were found to be statistically insignificant (P > 0.05), except for subgroups 5 and 7 (P ≤ 0.05). Immersing NiTi files in NaOCl or Irritrol with sterilisation for three times considerably reduced the cyclic fatigue resistance of these files. Reciproc files exhibited the highest cyclic fatigue resistance in comparison with ProTaper and WaveOne Gold files.
Collapse
Affiliation(s)
- Fatma Kermeoglu
- Department of Endodontics, Faculty of Dentistry, Near East University, Mersin10, Turkey
| | - Mohamad Abduljalil
- Department of Endodontics, Faculty of Dentistry, Near East University, Mersin10, Turkey
| |
Collapse
|
8
|
Omori S, Ebihara A, Hirano K, Kasuga Y, Unno H, Nakatsukasa T, Kimura S, Maki K, Hanawa T, Okiji T. Effect of Rotational Modes on Torque/Force Generation and Canal Centering Ability during Rotary Root Canal Instrumentation with Differently Heat-Treated Nickel-Titanium Instruments. MATERIALS (BASEL, SWITZERLAND) 2022; 15:6850. [PMID: 36234189 PMCID: PMC9571549 DOI: 10.3390/ma15196850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Revised: 09/18/2022] [Accepted: 09/27/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to evaluate how various rotational modes influence the torque/force production and shaping ability of ProTaper Universal (PTU; non-heat-treated) and ProTaper Gold (PTG; heat-treated) nickel−titanium instruments. J-shaped resin canals were instrumented with PTU or PTG using an automated instrumentation device operated with reciprocating rotation [150° clockwise and 30° counterclockwise (R150/30) or 240° clockwise and 120° counterclockwise (R240/120)], optimum torque reverse motion (OTR), or continuous rotation (CR) (n = 10 each). Maximum force and torque were recorded, and canal centering ratios were calculated. Statistical analysis was performed with two-way ANOVA and a Bonferroni test (α = 0.05). The results were considered with reference to previous studies on the microstructure of the instruments. The upward force generated by R240/120 and OTR was smaller than that generated by R150/30 and CR in PTG (p < 0.05). The clockwise torque produced by OTR was lower than that produced by R150/30 in PTU and R240/120 and CR in PTG (p < 0.05). R240/120 and OTR induced less canal deviation compared to CR in PTU at 0 mm from the apex (p < 0.05). In conclusion, R240/120 and OTR reduced the screw-in force in PTG and improved the canal centering ability in PTU, which may be associated with the heat treatment-induced microstructural difference of the two instruments.
Collapse
Affiliation(s)
- Satoshi Omori
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Keiko Hirano
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Yuka Kasuga
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Hayate Unno
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Taro Nakatsukasa
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Shunsuke Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Keiichiro Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| | - Takao Hanawa
- Department of Metallic Biomaterials, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University (TMDU), 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8549, Japan
| |
Collapse
|
9
|
Abstract
A very extensive literature review presents the possibilities and needs of using, in endodontics, the alloys commonly known as nitinol. Nitinol, as the most modern group of engineering materials used to develop root canals, is equilibrium nickel and titanium alloys in terms of the elements’ atomic concentration, or very similar. The main audience of this paper is engineers, tool designers and manufacturers, PhD students, and students of materials and manufacturing engineering but this article can also certainly be used by dentists. The paper aims to present a full material science characterization of the structure and properties of nitinol alloys and to discuss all structural phenomena that determine the performance properties of these alloys, including those applied to manufacture the endodontic tools. The paper presents the selection of these alloys’ chemical composition and processing conditions and their importance in the endodontic treatment of teeth. The results of laboratory studies on the analysis of changes during the sterilization of endodontic instruments made of nitinol alloys are also included. The summary of all the literature analyses is an SWOT analysis of strengths, weaknesses, opportunities, and threats, and is a forecast of the development strategy of this material in a specific application such as endodontics.
Collapse
|
10
|
Dablanca-Blanco AB, Arias A, Ginzo-Villamayor MJ, Pérez MC, Castelo-Baz P, Martín-Biedma B. Influence of operator expertise on glide path and root canal preparation of curved root canals with rotary and reciprocating motions. AUST ENDOD J 2021; 48:37-43. [PMID: 34699669 DOI: 10.1111/aej.12585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 09/25/2021] [Accepted: 10/06/2021] [Indexed: 11/30/2022]
Abstract
This study intended to help practitioners selecting the appropriate motion according to their level of expertise for glide path and complete root canal preparation of curved canals in terms of instrument fracture and preparation time. A total of 160 curved root canals (angle >30°, radius <6 mm) were allocated randomly to 4 groups: A/B for expert operators and C/D for nonexpert operators. A/C were shaped with rotary and B/D with reciprocating instruments. Preparation time was registered and compared with Kruskal-Wallis non-parametric test and Dunn's post hoc test. Instrument separation was also registered and compared with chi-square test. A fractographic analysis was performed with scanning electron microscopy. The use of reciprocation motions allowed nonexpert operators to avoid instrument breakage during glide path and to prepare root canals faster. Experts were equally effective in rotary/reciprocating root canal shaping and faster with rotary motions than nonexpert operators, who also fractured significantly more rotary instruments.
Collapse
Affiliation(s)
- Ana Belén Dablanca-Blanco
- Unit of Dental Pathology and Therapeutics II, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Ana Arias
- Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, Madrid, Spain
| | - María José Ginzo-Villamayor
- Department of Statistics, Mathematical Analysis and Optimization, University of Santiago de Compostela, Santiago de Compostela, Spain
| | | | - Pablo Castelo-Baz
- Unit of Dental Pathology and Therapeutics II, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Benjamín Martín-Biedma
- Unit of Dental Pathology and Therapeutics II, School of Medicine and Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| |
Collapse
|
11
|
Oliveira LSDJ, de Bragança RMF, Sarkis-Onofre R, Faria-E-Silva AL. The effectiveness of the supplementary use of the XP-endo Finisher on bacteria content reduction: a systematic review and meta-analysis. Restor Dent Endod 2021; 46:e37. [PMID: 34513643 PMCID: PMC8411000 DOI: 10.5395/rde.2021.46.e37] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 12/16/2020] [Indexed: 12/31/2022] Open
Abstract
Objectives This systematic review evaluated the efficacy of the supplementary use of the XP-endo Finisher on bacteria content reduction in the root canal system. Materials and Methods In-vitro studies evaluating the use of the XP-endo Finisher on bacteria content were searched in four databases in July 2020. Two authors independently screened the studies for eligibility. Data were extracted, and risk of bias was assessed. Data were meta-analyzed by using random-effects model to compare the effect of the supplementary use (experimental) or not (control) of the XP-endo Finisher on bacteria counting reduction, and results from different endodontic protocols were combined. Four studies met the inclusion criteria while 1 study was excluded from the meta-analysis due to its high risk of bias and outlier data. The 3 studies that made it to the meta-analysis had an unclear risk of bias for at least one criterion. Results No heterogeneity was observed among the results of the studies included in the meta-analysis. The study excluded from the meta-analysis assessing the bacteria counting deep in the dentin demonstrated further bacteria reduction upon the use of the XP-endo Finisher. Conclusions This systematic review found no evidence supporting the supplementary use of the XP-endo Finisher on further bacteria counting the reduction in the root canal.
Collapse
Affiliation(s)
| | | | | | - André Luis Faria-E-Silva
- Graduate Program in Health Sciences, Federal University of Sergipe, Aracaju, Brazil.,Graduate Program in Dentistry, Federal University of Sergipe, Aracaju, Brazil
| |
Collapse
|
12
|
Current technology in endodontic instrumentation: advances in metallurgy and manufacture. Br Dent J 2021; 231:49-57. [PMID: 34244648 DOI: 10.1038/s41415-021-3170-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Accepted: 10/14/2020] [Indexed: 11/08/2022]
Abstract
Since the introduction of nickel-titanium endodontic instruments, there have been a myriad of developments which can be confusing and sometimes contradictory. This article seeks to review and articulate these advances, and allow the reader to better understand the benefits and the limitations of the systems available. Ultimately, this helps clinicians to engage more confidently with trade and have a more informed choice of the most appropriate file to use for each individual endodontic case. All this should facilitate more predictable endodontic outcomes.
Collapse
|
13
|
Yalniz H, Koohnavard M, Oncu A, Celikten B, Orhan AI, Orhan K. Comparative evaluation of dentin volume removal and centralization of the root canal after shaping with the ProTaper Universal, ProTaper Gold, and One-Curve instruments using micro-CT. J Dent Res Dent Clin Dent Prospects 2021; 15:47-52. [PMID: 33927841 PMCID: PMC8058162 DOI: 10.34172/joddd.2021.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 11/29/2020] [Indexed: 11/19/2022] Open
Abstract
Background. The main goal of our study was to assess the volume of dentin removed and transportation in root canals using ProTaper Universal (PTU), ProTaper Gold (PTG) and One-Curve (OC). Ni-Ti rotary instruments in extracted human teeth using by micro-CT. Methods: Thirty human upper 1st premolar teeth with two separate root canals and sturdy, mature root tips were used in the present study. Specimens were decoronated and root length was standardized for micro CT scanning before root canal preparation done. The teeth were randomly separated into three categories (n = 10) according to the rotary NiTi system used for canal instrumentation, i.e., PTU (Dentsply, Maillefer), PTG (Dentsply, Maillefer), and OC (Micro-Mega SA). After root canal preparation, samples were scanned again on micro-CT by the same scanning parameters. Surface area, canal volume, structure model index (SMI), percentage of uninstrumented area and transportation parameters were obtained for each sample before and after micro-CT analyse. Results: No significant differences between the PTG and PTU in terms of the total volume of removed dentin, surface area and percentage of uninstrumented areas were found. However, regarding to parameters above, OC showed a lower efficacy than PTG and PTU in coronal section. Regarding canal transportation, PTG and OC showed lower mean transportation values at all levels. Conclusion: This paper demonstrated the root canal shaping abilities of the PTU, PTG, and OC NiTi file systems. The PTG and OC systems were associated less canal transportation and a better ability to preserve dentinal walls than PTU. There was no significance different between all rotary file systems for SMI values however, PTU and PTG showed greater canal volume and surface area change than OC file systems in coronal section.
Collapse
Affiliation(s)
- Hatice Yalniz
- Bezmialem Vakif University, Faculty of Dentistry, Department of Endodontics, Istanbul, Turkey
| | - Mehrdad Koohnavard
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Aysenur Oncu
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Berkan Celikten
- Ankara University, Faculty of Dentistry, Department of Endodontics, Ankara, Turkey
| | - Ayse Isil Orhan
- Ankara Yildirim Beyazit University, Department of Pediatric Dentistry, Ankara, Turkey
| | - Kaan Orhan
- Ankara University, Faculty of Dentistry, Department of DentoMaxillofacial Radiology, Ankara, Turkey
| |
Collapse
|
14
|
Nakatsukasa T, Ebihara A, Kimura S, Maki K, Nishijo M, Tokita D, Okiji T. Comparative evaluation of mechanical properties and shaping performance of heat-treated nickel titanium rotary instruments used in the single-length technique. Dent Mater J 2021; 40:743-749. [PMID: 33518688 DOI: 10.4012/dmj.2020-255] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
This study aimed to evaluate the mechanical properties of contemporary heat-treated nickel-titanium (NiTi) rotary instruments used in the single-length technique [ProTaper Next (PTN), HyFlex EDM (EDM), and JIZAI (JZ)]. Bending loads, cyclic fatigue resistance, torque/force values and canal-centering ratios were evaluated for the three instruments and a non-heat-treated experimental NiTi instrument with the same geometry as JZ (nJZ). EDM and JZ exhibited significantly lower bending load and more cycles to failure compared with nJZ and PTN (p<0.05). PTN and JZ exhibited significantly better centering ability than nJZ and EDM (p<0.05). JZ and nJZ generated significantly smaller upward force and maximum torque than PTN and EDM (p<0.05). Under the present experimental condition, JZ exhibited flexibility and cyclic fatigue resistance comparable to EDM, better maintained the canal curvature than the other instruments, and generated smaller torque and screw-in force than PTN and EDM.
Collapse
Affiliation(s)
- Taro Nakatsukasa
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Shunsuke Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Keiichiro Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Miki Nishijo
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Daisuke Tokita
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU)
| |
Collapse
|
15
|
Al-Nasrawi SJH, Ayad Jaber Z, Talib Al-Quraine N, Imhemed Aljdaimi A, Jabbar Abdul-Zahra Al-Hmedat S, Zidan S, Haider J. Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument. Int J Dent 2021; 2021:6676005. [PMID: 33531902 PMCID: PMC7837779 DOI: 10.1155/2021/6676005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 01/06/2021] [Accepted: 01/09/2021] [Indexed: 11/18/2022] Open
Abstract
Peracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic instruments in contact with PAA of a certain concentration may affect their fatigue resistance. Therefore, the aim of this study was to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary files. Three types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold (WOG). Each type was divided into three subgroups (n = 6 for each file type): (1) untreated instruments; (2) files immersed in 0.002% PAA; and (3) files immersed in 0.35% PAA. The performance of each file type was tested in a simulated canal. The number of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to 0.002% PAA except the PTG (P=0.209). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a relatively high or low concentration adversely affects the cyclic fatigue resistance. The PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.
Collapse
Affiliation(s)
| | - Zuha Ayad Jaber
- Department of Conservative Dentistry, Faculty of Dentistry, University of Kufa, Najaf, Iraq
| | | | - Abtesam Imhemed Aljdaimi
- College of Dentistry and Oral Surgery, Alasmarya of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, Libya
| | | | - Saleh Zidan
- Department of Dental Materials, Faculty of Dentistry, Sebha University, Sebha, Libya
| | - Julfikar Haider
- Department of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK
| |
Collapse
|
16
|
Hou XM, Yang YJ, Qian J. Phase transformation behaviors and mechanical properties of NiTi endodontic files after gold heat treatment and blue heat treatment. J Oral Sci 2020; 63:8-13. [PMID: 33281148 DOI: 10.2334/josnusd.19-0331] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Abstract
WaveOne Gold, ProTaper Gold, Reciproc Blue, ProTaper Next, WaveOne and ProTaper files were selected to compare the phase transformation behaviors and mechanical properties of nickel-titanium (NiTi) rotary files after gold heat and blue heat treatments. The reverse transformation finishing point temperatures of WaveOne Gold, ProTaper Gold, ProTaper Next and WaveOne were higher than those of the other two instruments investigated. At a deflection of 0.5 mm, the loads were significantly varied except for ProTaper Next and ProTaper Gold. At a deflection of 3.0 mm, the loads of Reciproc Blue and WaveOne Gold were significantly varied compared to WaveOne and ProTaper. Cycles to failure were reduced in the order of WaveOne Gold, Reciproc Blue, ProTaper Gold, ProTaper Next, WaveOne and ProTaper. NiTi instruments after gold heat and blue heat treatments exhibited significantly higher bending properties and cyclic fatigue resistances, representing an improved performance over traditional and M-wire instruments.
Collapse
Affiliation(s)
- Xiao-Mei Hou
- The Second Dental Center of Peking University School of Stomatology
| | - Yin-Jie Yang
- Department of Stomatology, Beijing Xicheng District Xinjiekou Community Health Service Center
| | - Jun Qian
- The Second Dental Center of Peking University School of Stomatology
| |
Collapse
|
17
|
Nehme W, Araji S, Michetti J, Zogheib C, Naaman A, Khalil I, Pages R, Basarab A, Mallet JP, Diemer F. Assessment of root canal transportation of 2Shape and ProTaper gold in mandibular molar mesial canals: A micro-computed tomographic study. Microsc Res Tech 2020; 84:746-752. [PMID: 33227176 DOI: 10.1002/jemt.23633] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Revised: 07/21/2020] [Accepted: 10/08/2020] [Indexed: 11/07/2022]
Abstract
The aim of this study was to compare shaping abilities of Protaper Gold® (PTG) and 2Shape® (TS) by using a new automatic process and micro-computed tomography (Micro-CT). 32 first mandibular molars with two separate mesial canals were selected. Only mesial roots were prepared with PTG and TS. Pre- and post-operative scans were performed using Micro-CT to provide volumes with a voxel size of 20 μm. Volumes, non-instrumented area, amount of transportation and centering ability in coronal, middle and apical third shaping time and procedural errors were recorded. TS and PTG increased the endodontic volume of 2.98 mm3 (±1.56) and 3.21 mm3 (±1.78) respectively with no statistical difference (p = .168) and no procedural errors. No significant difference was found concerning canal transportation among groups but only within the same group PTG (p value < .001) and TS (p value < .001). The mean centering ratio was significantly different only between the section levels for PTG (p value < .001) and TS (p value = .01); it was significantly reduced in the cervical third. The percentage of untouched canal walls ranged between 29.78% (±15.145) and 36.60% (±11.968) respectively for PTG and TS with no statistical difference among groups (p value = .168). TS and PTG with post machining heat treatment were able to produce centered preparations with no significant difference or procedural errors. TS system provided a shorter preparation time than PTG files.
Collapse
Affiliation(s)
- Walid Nehme
- Saint-Joseph University, IRIT, CNRS UMR 5505, Toulouse, France
| | - Stephanie Araji
- Saint-Joseph University, IRIT, CNRS UMR 5505, Toulouse, France
| | - Jérôme Michetti
- Saint-Joseph University, Campus des Sciences Medicales, Beirut, Lebanon
| | - Carla Zogheib
- Saint-Joseph University, IRIT, CNRS UMR 5505, Toulouse, France
| | - Alfred Naaman
- Saint-Joseph University, IRIT, CNRS UMR 5505, Toulouse, France
| | - Issam Khalil
- Saint-Joseph University, IRIT, CNRS UMR 5505, Toulouse, France
| | - Raphaël Pages
- Saint-Joseph University, Campus des Sciences Medicales, Beirut, Lebanon
| | - Adrian Basarab
- Saint-Joseph University, Campus des Sciences Medicales, Beirut, Lebanon
| | | | - Franck Diemer
- Faculté de Chirurgie Dentaire, CHU de Toulouse, University of Toulouse, Toulouse, France.,Clement Ader Institute, Toulouse, France
| |
Collapse
|
18
|
The Influence of NiTi Alloy on the Cyclic Fatigue Resistance of Endodontic Files. J Clin Med 2020; 9:jcm9113755. [PMID: 33233442 PMCID: PMC7700305 DOI: 10.3390/jcm9113755] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 11/20/2020] [Accepted: 11/20/2020] [Indexed: 11/19/2022] Open
Abstract
Background: The aim of this study was to analyze the influence of NiTi alloy in endodontic rotary instruments on cyclic fatigue resistance. Methods: One hundred and sixty-four (164) sterile endodontic rotary files were selected and distributed into the following study groups: A: 25.08 F2 ProTaper Universal (PTU) (n = 41); B: 25.06 X2 ProTaper Next (PTN) (n = 41); C: 25.08 F2 ProTaper Gold (PTG) (n = 41), and D: 25.06 ProFile Vortex Blue (PVB) (n = 41). A cyclic fatigue device was designed to conduct the static cyclic fatigue tests with stainless steel artificial root canals systems with 250 µm apical diameter, 60° curvature angle, 5 mm radius of curvature, 20 mm length, and 6% (25.06) and 8% taper (25.08). Failure of the endodontic rotary instrument was detected by a single operator through direct observation and was also filmed to allow measurement of the exact time to failure. Results were analyzed using the ANOVA test and Weibull statistical analysis. Results: All pairwise comparisons presented statistically significant differences between the time to failure for the NiTi alloy study groups (p < 0.001), except between the PTN and PVB study groups (p = 0.379). In addition, statistically significant differences between the number of cycles to failure for the NiTi alloy study groups (p < 0.001) were also observed. Conclusions: The NiTi CM-Gold wire alloy of the ProTaper Gold endodontic rotary files resulted in greater resistance to cyclic fatigue than ProFile Vortex Blue, ProTaper Next, and ProTaper Universal endodontic rotary files.
Collapse
|
19
|
Advancement of Mechanical Properties of Nickel-Titanium Rotary Endodontic Instruments by Spring Machining on the File Shaft. MATERIALS 2020; 13:ma13225246. [PMID: 33233623 PMCID: PMC7699742 DOI: 10.3390/ma13225246] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/09/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 11/17/2022]
Abstract
Nickel-titanium (NiTi) endodontic rotary instruments are used extensively in root canal procedures by both general dentists and specialists. However, their vulnerability to fracture is the major reason for clinicians' concern regarding their use. The objective of this study was to investigate the potential effects of spring machining of the file shaft on the fatigue and torsional resistances of NiTi rotary instruments. Three types of NiTi rotary systems with (S) and without (NS) spring machining were used in this study (n = 15 each): a spring file (SPR; #25/.06, SPR-S, SPR-NS), a ProTaper Next X2 (PTN; #25/variable taper, PTN-S, PTN-NS), and a ProTaper Gold F2 (PTG; #25/variable taper, PTG-S, PTG-NS). Spring machining was adjusted on the 6 mm of each file system's shaft via a laser cutting process. The number of rotation cycles until fracture (i.e., cyclic fatigue resistance), ultimate torsional strength, the distortion angle, and the toughness of each subgroup were estimated with specially designed devices. The results were analyzed using a paired t-test at a significance level of 95%. NiTi rotary instruments with spring machining exhibited a higher cyclic fatigue resistance than instruments without spring machining. The groups with spring machining exhibited a higher toughness and larger distortion angle than the groups without it (p < 0.05). In conclusion, spring machining on the shank of NiTi instruments may provide a stress-bearing area and attenuate the torsional and cyclic fatigue of NiTi rotary instruments.
Collapse
|
20
|
Azevedo MAD, Silva TGD, Fernandes Â, Piasecki L, Fariniuk LF, Silva Neto UXD. Endodontic Retreatment Using a Single Instrument from four Nickel-Titanium Systems - A Micro-CT Study. Braz Dent J 2020; 31:605-610. [DOI: 10.1590/0103-6440202003463] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Accepted: 07/01/2020] [Indexed: 01/15/2023] Open
Abstract
Abstract This study evaluated the efficiency of using a single instrument from three different rotary multi-file systems and compared them with that of a reciprocating single-file for endodontic retreatment by means of micro-CT. Sixty extracted canines were prepared using a size F2 ProTaper Universal file and obturated. After 30 days of storage at 37ºC and 100% humidity, the teeth were randomly divided into four groups (n=15) based on the type of instrument used to retreatment: ProTaper Next (PTN), ProTaper Gold (PTG), TRUShape 3D (TS), and WaveOne (WO). The canals were retreated using only the size 40 instrument from each system according to the manufacturer’s recommendations for torque and speed. The time required to remove the filling material was recorded in seconds. The amount of initial and residual filling material and the quantity of dentin removed were assessed by means of micro-CT. Data were statistically analyzed (ANOVA and Kruskal-Wallis) at a 5% significance level. TS instruments required the highest (p<0.05) amount of time (mean, 384.80 ±144.92) compared with the WO (229.67±68.16) and PTG (248.67±64.22) and not so different from PTN instruments (327.67±133.3). No differences in the amount of dentin removed, initial and residual filling volume, and percentages of filling material were observed among the groups. The use of a single rotary instrument from the PTG, TS, and PTN systems was as effective as that of the single-file reciprocating WO system. However, none of the instruments was able to remove the filling materials completely.
Collapse
|
21
|
Tufenkci P, Orhan K, Celikten B, Bilecenoglu B, Gur G, Sevimay S. Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systems. Restor Dent Endod 2020; 45:e30. [PMID: 32839711 PMCID: PMC7431932 DOI: 10.5395/rde.2020.45.e30] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 03/04/2020] [Accepted: 03/04/2020] [Indexed: 11/11/2022] Open
Abstract
Objectives This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.
Collapse
Affiliation(s)
- Pelin Tufenkci
- Department of Endodontics, Faculty of Dentistry, Hatay Mustafa Kemal University, Antakya, Turkey
| | - Kaan Orhan
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey.,OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Leuven, Belgium.,Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium
| | - Berkan Celikten
- Department of Endodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Burak Bilecenoglu
- Department of Anatomy, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Gurkan Gur
- Department of Conservative Dentistry, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Semra Sevimay
- Department of Endodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| |
Collapse
|
22
|
Tüfenkçi P, Yılmaz K. The Effects of Different Endodontic Access Cavity Design and Using XP-endo Finisher on the Reduction of Enterococcus faecalis in the Root Canal System. J Endod 2020; 46:419-424. [DOI: 10.1016/j.joen.2019.11.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 11/16/2019] [Accepted: 11/23/2019] [Indexed: 12/16/2022]
|
23
|
Park SJ, Park SH, Cho KM, Ji HJ, Lee EH, Kim JW. Comparison of vibration characteristics of file systems for root canal shaping according to file length. Restor Dent Endod 2020; 45:e51. [PMID: 33294416 PMCID: PMC7691267 DOI: 10.5395/rde.2020.45.e51] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2020] [Revised: 07/30/2020] [Accepted: 08/04/2020] [Indexed: 12/03/2022] Open
Abstract
Objectives No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.
Collapse
Affiliation(s)
- Seong-Jun Park
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Se-Hee Park
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Kyung-Mo Cho
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Hyo-Jin Ji
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| | - Eun-Hye Lee
- Department of Conservative Dentistry, Hanyang University Seoul Hospital, Seoul, Korea
| | - Jin-Woo Kim
- Department of Conservative Dentistry, Gangneung-Wonju National University, Gangneung, Korea
| |
Collapse
|
24
|
Flexural Fatigue of Unicone, Navigator Evo and Protaper Next Files in Reciprocate and Continuous Rotary Systems in Simulated Curved Canals—An In Vitro Study. METALS 2019. [DOI: 10.3390/met10010023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study investigated the cyclic fatigue resistance of three brands of nickel-titanium rotary files—Unicone (size 25 0.06; Medin), Navigator Evo (W-4; size 25 0.06; Medin) and Protaper Next (X2; size 25 0.06 Dentsply Tulsa Dental)—in reciprocating and continuous motion, during artificial canal instrumentation. Seventy-two samples—Unicone (n = 24), Navigator Evo (n = 24), and Protaper Next (n = 24)—each measuring 25 mm in length, were allocated to reciprocating (n = 36) and continuous motion (n = 36) experimental subgroups, and rotated in a simulated steel curved canal until fracture occurred. Fracture times and fragment lengths of samples in the experimental subgroups were recorded. One of the Unicone, Navigator Evo and Protaper Next fractured samples was randomly selected and analyzed for topographic characteristics by using scanning electron microscopy. Times to fracture and fragment lengths of samples were evaluated by analysis of variance and Tukey’s tests. Independent sample t test was used to compare mean values between the different groups. Protaper Next samples displayed significantly higher resistance to cyclic fatigue in reciprocating motion than Unicone and Navigator Evo samples (p < 0.001). Unicone samples exhibited the least fracture-resistant in continuous and reciprocating motion.
Collapse
|
25
|
Gündoğar M, Özyürek T, Yılmaz K, Uslu G. Cyclic fatigue resistance of HyFlex EDM, Reciproc Blue, WaveOne Gold, and Twisted File Adaptive rotary files under different temperatures and ambient conditions. J Dent Res Dent Clin Dent Prospects 2019; 13:166-171. [PMID: 31857861 PMCID: PMC6904914 DOI: 10.15171/joddd.2019.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 07/23/2019] [Indexed: 11/09/2022] Open
Abstract
Background. This study examined the effects of changes in temperature and environmental conditions on the cyclic fatigue resistance of Reciproc Blue, HyFlex EDM, WaveOne Gold, and Twisted File Adaptive. Methods. Forty-five Reciproc Blue (25/.08), 45 HyFlex EDM (25/.08), 45 WaveOne Gold (25/.07), and 45 Twisted File Adaptive (25/.08) files were tested for cyclic fatigue at room temperature (20°C) in air and water and at body temperature (35°C) in water. All the instruments were rotated in artificial canals made of stainless steel with an inner diameter of 1.5 mm, 60° angle of curvature and a radius of curvature of 5 mm until fracture occurred; the time to fracture was recorded in seconds, using a digital chronometer. Mann-Whitney U test was used for the statistical analysis of data, with SPSS 21.0. Results. Cyclic fatigue resistance was significantly higher in all the groups in water at an ambient temperature of 20°C compared with air and water at temperatures of 20°C and 35°C, respectively (P<0.05). The intragroup analysis revealed that HyFlex EDM had the highest cyclic fatigue resistance, followed by Reciproc Blue, WaveOne Gold, and Twisted File Adaptive in both air and water at 20°C (P<0.05). HyFlex EDM exhibited the highest cyclic fatigue resistance in water at 35°C, whereas there was no significant difference between the other groups (P>0.05). Conclusion. Within the limitations of the present study, an increase in the ambient temperature significantly decreased the cyclic fatigue resistance of the tested NiTi files.
Collapse
Affiliation(s)
- Mustafa Gündoğar
- Department of Endodontics, Faculty of Dentistry, Medipol University, İstanbul, Turkey
| | - Taha Özyürek
- Department of Endodontics, Faculty of Dentistry, Istanbul Medeniyet University, İstanbul, Turkey
| | - Koray Yılmaz
- Department of Endodontics, Faculty of Dentistry, Hatay Mustafa Kemal University, Hatay, Turkey
| | - Gülşah Uslu
- Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| |
Collapse
|
26
|
Abstract
Ever since their introduction, nickel–titanium (NiTi) alloys have continued to revolutionize the field of endodontics. They have considerable advantages over the conventional stainless steel file in terms of mechanical properties. However, despite of their superior mechanical properties, NiTi alloys still pose some risk of fracture. Consequently, there has been considerable research conducted to investigate the mechanisms behind the occurrence of these procedural errors. Since the last decade, different proprietary processing procedures have been introduced to further improve the mechanical properties of NiTi alloys. These treatments include thermal, mechanical, electropolishing, and recently introduced electric discharge machining. The main purpose of these treatments is to impart a more martensitic phase into the files at normal body temperature, so that the maximum advantage of flexibility can be obtained. These heat-treated instruments also possess improved cyclic fatigue resistance when compared to conventional NiTi alloys. NiTi alloys can be subclassified as the instruments mainly containing austenitic phase (conventional NiTi, M-wire, R-phase), and those containing martensitic phase (controlled memory wire, ProTaper Gold, and Vortex Blue). Instruments based on austenitic alloys possess superelastic properties due to the stress-induced martensitic transformation. Contrary to this, martensitic alloys can easily be deformed due to phase transformation, and they can demonstrate the shape memory effect when heated. This review discusses the different phase transformations and heat treatments that the NiTi instruments undergo.
Collapse
|
27
|
Scott R, Arias A, Macorra JC, Govindjee S, Peters OA. Resistance to cyclic fatigue of reciprocating instruments determined at body temperature and phase transformation analysis. AUST ENDOD J 2019; 45:400-406. [DOI: 10.1111/aej.12374] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2019] [Indexed: 10/25/2022]
Affiliation(s)
- Raymond Scott
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
| | - Ana Arias
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
- Department of Conservative Dentistry and Prothesis School of Dentistry Complutense University Madrid Spain
| | - José C. Macorra
- Department of Conservative Dentistry and Prothesis School of Dentistry Complutense University Madrid Spain
| | - Sanjay Govindjee
- Department of Civil and Environmental Engineering University of California Berkeley California USA
| | - Ove A. Peters
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
- Oral Health Centre University of Queensland Herston Queensland Australia
| |
Collapse
|
28
|
Algahtani F, Huang X, Haapasalo M, Wang Z, Hieawy A, Zhang D, Aleksejuniene J, Shen Y. Fatigue resistance of ProTaper gold exposed to high-concentration sodium hypochlorite in double curvature artificial canal. Bioact Mater 2019; 4:245-248. [PMID: 31528756 PMCID: PMC6739284 DOI: 10.1016/j.bioactmat.2019.07.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2019] [Revised: 07/10/2019] [Accepted: 07/30/2019] [Indexed: 01/28/2023] Open
Abstract
This study aimed to evaluate and compare the fatigue resistance of ProTaper Gold (PTG) and ProTaper Universal (PTU) in artificial single and double curvature canals in 5% sodium hypochlorite (NaOCl) at body temperature (37 °C). PTG and PTU files (size F1) were subjected to fatigue tests in two different artificial ceramic canals. The single curvature model had a 60° curvature angle with a 5 mm radius. The double curvature model had a 60° curvature angle with a 5 mm radius and a second 30° curvature with a 2 mm radius. A file segment was introduced into the artificial canal and immersed in water or 5% NaOCl at 37 °C. The total number of cycles to fracture (NCF) was recorded. Data were analyzed using t-test and linear regression analysis. The NCF of all files was significantly influenced by the type of NiTi metal alloy (P < .01), canal curvatures (P < .01), and the environmental conditions (P < .05). PTG had higher fatigue resistance than PTU files in both single and double curvature canals (P < .05). The NCF of PTU files in 5% NaOCl was shorter than that in water (P < .05). The mean length of broken PTG was significantly shorter than those of PTU files in both single and double curvature canals (P < .01). The fatigue performance of PTG is better than that of PTU in both single and double curvature. Environmental conditions may affect the fatigue behavior of PTU files with single curvature.
Collapse
Affiliation(s)
- Fahda Algahtani
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada.,College of Dentistry, Princess Nourah Bint Abdulrahman University, Saudi Arabia
| | - Xiangya Huang
- Department of Conservative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-Sen University, Guangzhou, China.,Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Markus Haapasalo
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Zhejun Wang
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Ahmed Hieawy
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Duo Zhang
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Jolanta Aleksejuniene
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| | - Ya Shen
- Department of Oral Biological and Medical Sciences, Faculty of Dentistry, The University of British Columbia, Vancouver, Canada
| |
Collapse
|
29
|
Hülsmann M, Donnermeyer D, Schäfer E. A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments. Int Endod J 2019; 52:1427-1445. [PMID: 31267579 DOI: 10.1111/iej.13182] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 06/30/2019] [Indexed: 11/29/2022]
Abstract
The endodontic literature contains a plethora of studies on static and dynamic cyclic fatigue resistance tests performed on a large array of rotary or reciprocating nickel-titanium endodontic instruments. It was the aim of this review to summarize the currently available evidence to point out the different outcomes from static versus dynamic tests and to assess whether cyclic fatigue tests provide useful data and information for clinical practice. An electronic literature research in the database PubMed was performed using appropriate search terms, and the titles and abstract were screened for relevance. Language was restricted to English. The review reveals marked differences between the results obtained in static and dynamic tests, and also, the results for the same instruments assessed either under static or dynamic experimental conditions are widely inconsistent. Between the lowest and the highest value for one and the same pathfinding instrument was a factor of about 123 when cyclic fatigue was assessed either under static or dynamic experimental conditions. Moreover, standard deviations of up to 30% have been reported. Environmental temperature has a 500% impact on the lifetime of instruments. In conclusion, fatigue resistance tests conducted under room temperature should be regarded as having little meaning and the scientific and clinical benefits of fatigue resistance tests are very limited. These data should be provided by the manufacturer of the instruments.
Collapse
Affiliation(s)
- M Hülsmann
- Department of Preventive Dentistry, Periodontology and Cariology, University Medicine Göttingen (UMG), Göttingen, Germany
| | - D Donnermeyer
- Department of Periodontology and Operative, Westphalian Wilhelms-University, Münster, Germany
| | - E Schäfer
- Central Interdisciplinary Ambulance, Westphalian Wilhelms-University, Münster, Germany
| |
Collapse
|
30
|
Galal M, Ismail AG, Omar N, Zaazou M, Nassar MA. Influence of Thermomechanical Treatment on the Mechanical Behavior of Protaper Gold versus Protaper Universal (A Finite Element Study). Open Access Maced J Med Sci 2019; 7:2157-2161. [PMID: 31456845 PMCID: PMC6698121 DOI: 10.3889/oamjms.2019.552] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 06/09/2019] [Accepted: 06/20/2019] [Indexed: 11/23/2022] Open
Abstract
AIM: To compare and evaluate the influence of thermomechanical treatment of Protaper Gold file versus Protaper Universal file during testing of bending and torsion using finite-element analysis. METHODS: Two nickel-titanium NiTi rotary files (ProTaper Gold and ProTaper Universal) were used in this study. The files were imaged using stereomicroscope to produce 3D models. The behaviour of the instrument during bending and torsion was numerically analysed in CAD/CAM software package. RESULTS: Under bending, ProTaper, Gold showed higher flexibility and flexural resistance than ProTaper Universal. The highest stress was related at the cutting edge of both files. While during testing of torsion, the maximum amount of stresses was related to the base of the flutes in both files. ProTaper Gold showed higher torsional resistance than the ProTaper Universal file. CONCLUSION: Thermomechanical treatment improved the mechanical response (bending and torsional resistance) of NiTi files.
Collapse
Affiliation(s)
- Manar Galal
- Restorative and Dental Materials Department, National Research Centre, Cairo, Egypt
| | - Amira Galal Ismail
- Restorative and Dental Materials Department, National Research Centre, Cairo, Egypt
| | - Nada Omar
- Restorative and Dental Materials Department, National Research Centre, Cairo, Egypt
| | - Mohamed Zaazou
- Restorative and Dental Materials Department, National Research Centre, Cairo, Egypt
| | | |
Collapse
|
31
|
Alqedairi A, Alfawaz H, Abualjadayel B, Alanazi M, Alkhalifah A, Jamleh A. Torsional resistance of three ProTaper rotary systems. BMC Oral Health 2019; 19:124. [PMID: 31226984 PMCID: PMC6588856 DOI: 10.1186/s12903-019-0820-7] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Accepted: 06/12/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The aim of this study is to compare the torsional resistance of the available ProTaper rotary systems, namely, ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG). METHODS A total of 195 files from the three systems distributed into 13 groups (PTU-S1, PTU-S2, PTU-F1, PTU-F2, PTU-F3, PTG-S1, PTG-S2, PTG-F1, PTG-F2, PTG-F3, PTN-X1, PTN-X2 and PTN-X3) were subjected to torsional fatigue until failure. The torsional test was performed according to ISO 3630-1, where each file was placed in a straight position to eliminate the influence of cyclic fatigue. The Kruskal-Wallis test was conducted to compare the mean maximum torques and angular deflections at fracture for the groups, and the Mann-Whitney test was performed for pairwise comparisons. The significance level was set at 0.05 and the fractured surfaces were examined under a scanning electron microscope. RESULT Among the tested files, PTG-S1 had the lowest torsional fatigue resistance, whereas PTU-F2 and PTU-F3 had the highest torsional resistance. The scanning electron microscope showed typical features of torsional failure. CONCLUSION The new ProTaper systems (PTG and PTN) did not show improved torsional resistance in comparison with PTU.
Collapse
Affiliation(s)
- Abdullah Alqedairi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Hussam Alfawaz
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Bader Abualjadayel
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Mohammad Alanazi
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Ahmad Alkhalifah
- Department of Restorative Dental Sciences, College of Dentistry, King Saud University, Riyadh, Kingdom of Saudi Arabia
| | - Ahmed Jamleh
- King Abdullah International Medical Research Centre, Restorative and Prosthetic Dental Sciences, College of Dentistry, Ministry of National Guard Health Affairs, King Saud bin Abdulaziz University for Health Sciences, P.O. Box 22490, Riyadh, 11426, Saudi Arabia.
| |
Collapse
|
32
|
Khalil WA, Natto ZS. Cyclic fatigue, bending resistance, and surface roughness of ProTaper Gold and EdgeEvolve files in canals with single- and double-curvature. Restor Dent Endod 2019; 44:e19. [PMID: 31149617 PMCID: PMC6529793 DOI: 10.5395/rde.2019.44.e19] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 01/31/2019] [Accepted: 03/26/2019] [Indexed: 11/25/2022] Open
Abstract
Objectives The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files. Materials and Methods The instruments (n = 15/each) were tested for cyclic fatigue in single- (60° curvature, 5-mm radius) and double-curved (coronal curvature 60°, 5-mm radius, and apical curvature of 30° and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach 45°. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra). Results EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p < 0.05) and both files were more resistant to cyclic fatigue in single-curved canals than double-curved canals (p < 0.05). EdgeEvolve files exhibited significantly more flexibility than did ProTaper Gold files (p < 0.05). Both files had approximately similar Ni and Ti contents (p > 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05). Conclusions Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.
Collapse
Affiliation(s)
- Wafaa A Khalil
- Department of Endodontics, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Zuhair S Natto
- Department of Dental Public Health, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
33
|
Fernández-Pazos G, Martín-Biedma B, Varela-Patiño P, Ruíz-Piñón M, Castelo-Baz P. Fracture and deformation of ProTaper Next instruments after clinical use. J Clin Exp Dent 2019; 10:e1091-e1095. [PMID: 30607226 PMCID: PMC6311394 DOI: 10.4317/jced.54910] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Accepted: 10/15/2018] [Indexed: 11/25/2022] Open
Abstract
Background The aim of this study was to evaluate the fracture and defects observed in ProTaper Next files discarded after a normal clinical use. Material and Methods 571 ProTaper Next rotary instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, later all the files were evaluated under a stereomicroscope to observe defects such as unwinding, curving or fracture. The data obtained were analyzed using a chi-square and z test. Results 13.83% of the discarded files showed defects, the most frequent defect was fracture (7.53%). The highest rate of fracture was observed in the X1 (17.04) files (19.87%). The presence of deformations without fracture was also more frequent in the 17.04 file (11.8%). Conclusions Because of the relatively high incidence of deformation of smaller files, these instruments should be considered as a single use. It is important not to exceed the maximum uses recommended by the manufacturer to reduce the risk of cyclic fatigue, the main cause of fracture of the files (79.07%). It is also important to observe each file after use to discard small defects or fractures. Key words:Clinical use, deformation, fracture, M-Wire, ProTaper Next.
Collapse
Affiliation(s)
- Gema Fernández-Pazos
- Department of Pathology and Dental Therapeutics II, Universidad de Santiago de Compostela, Galicia, Spain
| | - Benjamín Martín-Biedma
- Department of Pathology and Dental Therapeutics II, Universidad de Santiago de Compostela, Galicia, Spain
| | - Purificación Varela-Patiño
- Department of Pathology and Dental Therapeutics II, Universidad de Santiago de Compostela, Galicia, Spain
| | - Manuel Ruíz-Piñón
- Department of Pathology and Dental Therapeutics II, Universidad de Santiago de Compostela, Galicia, Spain
| | - Pablo Castelo-Baz
- Department of Pathology and Dental Therapeutics II, Universidad de Santiago de Compostela, Galicia, Spain
| |
Collapse
|
34
|
Gavini G, Santos MD, Caldeira CL, Machado MEDL, Freire LG, Iglecias EF, Peters OA, Candeiro GTDM. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res 2018; 32:e67. [PMID: 30365608 DOI: 10.1590/1807-3107bor-2018.vol32.0067] [Citation(s) in RCA: 103] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 06/11/2018] [Indexed: 11/22/2022] Open
Abstract
The introduction of automated instrumentation in endodontics represented a major advance in progress for this specialty, with improvements in the quality and predictability of root canal preparation and a significant reduction in procedural errors. In recent years, endodontic instruments have undergone a series of changes brought about by modifications in design, surface treatments, and thermal treatments. In addition, new movements have also been incorporated to offer greater safety and efficiency, optimizing the properties of the NiTi alloy, especially through eccentric rotary motion. An understanding of the mechanical properties of these new NiTi instruments and their effect on the clinical performance of root canal preparation is essential if dental practitioners are to select the instruments that provide optimal clinical outcomes, especially in curved or flattened canals. The objective of this literature review is to present and discuss the characteristics of the NiTi alloys used in the major instrumentation systems available in the market, as well as the influence of the metallurgical and mechanical properties of NiTi instruments and the movements that drive them, to enable more accurate and predictable planning of root canal preparation.
Collapse
Affiliation(s)
- Giulio Gavini
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Marcelo Dos Santos
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Celso Luis Caldeira
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | | | - Laila Gonzales Freire
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Elaine Faga Iglecias
- Universidade de São Paulo - USP, School of Dentistry, Discipline of Endodontics, São Paulo, SP, Brazil
| | - Ove Andrea Peters
- University of the Pacific, Arthur A. Dugoni School of Dentistry, Department of Endodontics, San Francisco, CA, United States
| | | |
Collapse
|
35
|
Machado MEDL, Nabeshima CK, Caballero-Flores H, Elmadjian-Filho M, Duarte MAH, Odinola-Zapata R, Cai S. Instrument Design May Influence Bacterial Reduction During Root Canal Preparation. Braz Dent J 2018; 28:587-591. [PMID: 29215683 DOI: 10.1590/0103-6440201701506] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 06/20/2017] [Indexed: 11/22/2022] Open
Abstract
The aim of this study was to evaluate the bacterial reduction promoted by ProTaper Next and Twisted File by comparing to ProTaper Universal and manual technique. Sixty distobuccal root canals of maxillary molars sterilized with ethylene oxide were contaminated with Enterococcus faecalis broth culture. After incubation for 21 days, bacterial samples were collected and cultured on m-Enterococcus agar plates. The root canals were divided into 4 groups, according to the system used for instrumentation: ProTaper Next, Twisted File, ProTaper Universal, and crown down manual technique. Other 8 uncontaminated root canals were control asepsis. Bacterial samples were collected immediately and 7 days after instrumentation. The bacterial reduction was calculated and then made intragroup analysis by paired t-test and intergroup analysis by ANOVA and Tukey tests, all at 5% significance. All techniques significantly reduced the bacterial number in the root canal (p<0.05). ProTaper Next and Twisted File resulted in more bacterial reduction than ProTaper Universal and manual technique (p<0.05). ProTaper Next and Twisted File were similar (p>0.05). It can be concluded that ProTaper Next and Twisted File promote a higher bacterial reduction than Protaper Universal and manual technique.
Collapse
Affiliation(s)
| | - Cleber Keiti Nabeshima
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | - Hector Caballero-Flores
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | - Moyzés Elmadjian-Filho
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | | | - Ronald Odinola-Zapata
- Department of Endodontics, Bauru School of Dentistry, USP - Universidade de São Paulo, Bauru, SP, Brazil
| | - Silvana Cai
- Derpartment of Microbiology, Institute of Biological Science, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
36
|
Guillén RE, Nabeshima CK, Caballero-Flores H, Cayón MR, Mercadé M, Cai S, Machado MEDL. Evaluation of the WaveOne Gold and One Shape New Generation in Reducing Enterococcus faecalis from Root Canal. Braz Dent J 2018; 29:249-253. [PMID: 29972450 DOI: 10.1590/0103-6440201801910] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2017] [Accepted: 03/01/2018] [Indexed: 01/22/2023] Open
Abstract
The aim of this study was to evaluate the WaveOne Gold and One Shape New Generation systems regarding the bacterial removal from root canals infected with Enterococcus faecalis by comparing them to the conventional WaveOne and One Shape systems. Forty-eight distobuccal root canals of maxillary molars sterilized with ethylene oxide were infected with E. faecalis for 21 days, and then root canal initial bacterial sample was collected with paper cones and plated on M-enterococcus agar. The specimens were randomly divided into 4 groups according to the instrumentation: WaveOne Gold, One Shape New Generation, WaveOne and One Shape. After instrumentation, samples were collected with use of scraping and paper cones at immediate and 7 days after instrumentation. The bacterial reduction was calculated and then made intragroup analysis by Friedman test and intergroup analysis by Kruskal-Wallis with Dunn's post-hoc test, all at 5% significance. All techniques significantly reduced the number of bacteria in the root canal (p<0.05). WaveOne Gold and One Shape New Generation promoted higher bacterial reduction than WaveOne and One Shape systems (p<0.05), but no significant difference was found between WaveOne Gold and One Shape New Generation or between WaveOne and One Shape (p>0.05). Novel single-file systems promote better bacterial removal than the conventional single-file systems.
Collapse
Affiliation(s)
- Raquel Esmeralda Guillén
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | - Cleber Keiti Nabeshima
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | - Hector Caballero-Flores
- Department of Restorative Dentistry, School of Dentistry, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | - Miguel Roig Cayón
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, CT, Spain
| | - Montse Mercadé
- Department of Dentistry, Universitat de Barcelona, Barcelona, CT, Spain
| | - Silvana Cai
- Derpartment of Microbiology, Institute of Biological Science, USP - Universidade de São Paulo, São Paulo, SP, Brazil
| | | |
Collapse
|
37
|
Nishad SV, Shivamurthy GB. Comparative Analysis of Apical Root Crack Propagation after Root Canal Preparation at Different Instrumentation Lengths Using ProTaper Universal, ProTaper Next and ProTaper Gold Rotary Files: An In vitro Study. Contemp Clin Dent 2018; 9:S34-S38. [PMID: 29962761 PMCID: PMC6006869 DOI: 10.4103/ccd.ccd_830_17] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Aim To compare the incidence of apical root crack formation after root canal preparation at different instrumentation lengths using ProTaper Universal (PTU), ProTaper Next (PTN) and ProTaper Gold (PTG) file systems. Subjects and Methods Eighty-four mandibular first premolars with single and straight root canal were mounted in resin block after simulating periodontal ligaments. 1-2 mm of root apex was exposed followed by sectioning of 1 mm of root tip for better stereomicroscopic visualization. While the Control group was left unprepared, experimental groups were instrumented up to root canal length (RCL) and (RCL-1 mm) respectively using PTU, PTN and PTG. After staining the root apex with 1% methylene blue dye, stereomicroscopic images were obtained for evaluating apical root cracks. The data were analyzed using Chi-square, phi and Cramer test. The significance level was set at P < 0.05. Results Significantly less dentinal defects were seen between PTG and PTU while there was no significant difference between PTU-PTN and PTN-PTG. Furthermore, samples instrumented up to RCL-1 mm showed lesser cracks as compared with samples instrumented up to RCL. Conclusion PTG produced least number of cracks followed by PTN and PTU. Furthermore, instrumenting short of RCL reduced the crack formation risk.
Collapse
Affiliation(s)
- Sonalkumari Vakilram Nishad
- Department of Conservative Dentistry and Endodontics, College of Dental Sciences, Davangere, Karnataka, India
| | - G B Shivamurthy
- Department of Conservative Dentistry and Endodontics, College of Dental Sciences, Davangere, Karnataka, India
| |
Collapse
|
38
|
Yammine S, Jabbour E, Diemer F, Majzoub Z. Canal Straightening Following Overinstrumentation with Three Nickel-Titanium Rotary Instruments. J Int Soc Prev Community Dent 2018; 8:245-251. [PMID: 29911063 PMCID: PMC5985682 DOI: 10.4103/jispcd.jispcd_18_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Accepted: 01/30/2018] [Indexed: 12/22/2022] Open
Abstract
AIM The aim of the present in vitro study to compare canal straightening following shaping of curved canals with three types of new generation nickel-titanium (NiTi) rotary instruments-ProTaper Next (PTN)®, BT RaCe (BTR)®, and WaveOne Gold (WOG)®- and three different levels of protrusion beyond the major apical foramen. MATERIALS AND METHODS Forty-five extracted human maxillary and mandibular molars with at least one curved canal were distributed in three comparable groups of 15 canals each. The canals were instrumented to the major foramen and then overinstrumented with the final file 0.5 mm, 1 mm, and 1.5 mm beyond the foramen using PTN (Group PTN = 15), BTR (Group BTR = 15), and WOG (Group WOG = 15). Standardized pre- and post-instrumentation radiographs of the root canal were obtained for all groups using digital intraoral radiographs coupled with software. Differences in the degree of curvature were regarded as straightening and canal curvature was evaluated based on Schneider technique using the AmScope software for measurements and compared between groups and levels of instrumentation applying Mixed-model ANOVA. Significance was set at 0.05. RESULTS Canal curvature tended to gradually straighten out as the level of instrumentation increased in all three groups without statistically significant difference among the groups (P = 0.826). CONCLUSION Overinstrumentation in curved canals resulted in straightening of the canal curvature.
Collapse
Affiliation(s)
- Salwa Yammine
- Department of Endodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| | - Edgard Jabbour
- Department of Endodontics, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| | - Franck Diemer
- Université Paul Sabatier, Institut Clément Ader, CHU de Toulouse, France
| | - Zeina Majzoub
- Department of Periodontology, Faculty of Dental Medicine, Lebanese University, Hadath, Beirut, Lebanon
| |
Collapse
|
39
|
Zupanc J, Vahdat-Pajouh N, Schäfer E. New thermomechanically treated NiTi alloys - a review. Int Endod J 2018; 51:1088-1103. [DOI: 10.1111/iej.12924] [Citation(s) in RCA: 166] [Impact Index Per Article: 27.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 03/16/2018] [Indexed: 11/29/2022]
Affiliation(s)
- J. Zupanc
- Department of Periodontology and Operative Dentistry; Westphalian Wilhelms-University; Münster Germany
| | - N. Vahdat-Pajouh
- Department of Periodontology and Operative Dentistry; Westphalian Wilhelms-University; Münster Germany
| | - E. Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry; Münster Germany
| |
Collapse
|
40
|
Park HJ, Seo MS, Moon YM. Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals. Restor Dent Endod 2018; 43:e3. [PMID: 29487834 PMCID: PMC5816992 DOI: 10.5395/rde.2018.43.e3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Accepted: 11/28/2017] [Indexed: 11/11/2022] Open
Abstract
Objectives The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods Thirty canals with 20°-45° of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.
Collapse
Affiliation(s)
| | - Min-Seock Seo
- Department of Conservative Dentistry, Wonkwang University Daejeon Dental Hospital, Wonkwang University, Daejeon, Korea
| | - Young-Mi Moon
- Department of Conservative Dentistry, Wonkwang University Daejeon Dental Hospital, Wonkwang University, Daejeon, Korea
| |
Collapse
|
41
|
Özyürek T, Yılmaz K, Uslu G. The effects of autoclave sterilization on the cyclic fatigue resistance of ProTaper Universal, ProTaper Next, and ProTaper Gold nickel-titanium instruments. Restor Dent Endod 2017; 42:301-308. [PMID: 29142878 PMCID: PMC5682146 DOI: 10.5395/rde.2017.42.4.301] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Accepted: 09/19/2017] [Indexed: 11/17/2022] Open
Abstract
Objectives It was aimed to compare the cyclic fatigue resistances of ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG) and the effects of sterilization by autoclave on the cyclic fatigue life of nickel-titanium (NiTi) instruments. Materials and Methods Eighty PTU, 80 PTN, and 80 PTG were included to the present study. Files were tested in a simulated canal. Each brand of the NiTi files were divided into 4 subgroups: group 1, as received condition; group 2, pre-sterilized instruments exposed to 10 times sterilization by autoclave; group 3, instruments tested were sterilized after being exposed to 25%, 50%, and 75% of the mean cycles to failure, then cycled fatigue test was performed; group 4, instruments exposed to the same experiment with group 3 without sterilization. The number of cycles to failure (NCF) was calculated. The data was statistically analyzed by using one-way analysis of variance and post hoc Tukey tests. Results PTG showed significantly higher NCF than PTU and PTN in group 1 (p < 0.05). Sterilization significantly increased the NCF of PTN and PTG (p < 0.05) in group 2. PTN in group 3 had significantly higher cyclic fatigue resistance than PTN group 4 (p < 0.05). Also, significantly higher NCF was observed for PTG in group 2 than in groups 3 and 4 (p < 0.05). Conclusions PTG instrument made of new gold alloy was more resistant to fatigue failure than PTN and PTU. Autoclaving increased the cyclic fatigue resistances of PTN and PTG.
Collapse
Affiliation(s)
- Taha Özyürek
- Department of Endodontics, Ondokuz Mayıs University Faculty of Dentistry, Samsun, Turkey
| | | | - Gülşah Uslu
- Department of Endodontics, Ondokuz Mayıs University Faculty of Dentistry, Samsun, Turkey
| |
Collapse
|
42
|
Vasconcelos RA, Arias A, Peters OA. Lateral and axial cutting efficiency of instruments manufactured with conventional nickel-titanium and novel gold metallurgy. Int Endod J 2017; 51:577-583. [DOI: 10.1111/iej.12822] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2017] [Accepted: 07/20/2017] [Indexed: 11/30/2022]
Affiliation(s)
- R. A. Vasconcelos
- Department of Endodontics; Arthur A Dugoni School of Dentistry; University of the Pacific; San Francisco CA USA
- Department of Restorative Dentistry; Sao Jose dos Campos School of Dentistry; Institute of Science and Technology Sao Jose dos Campos ICT/UNESP; Sao Jose dos Campos SP Brazil
| | - A. Arias
- Department of Endodontics; Arthur A Dugoni School of Dentistry; University of the Pacific; San Francisco CA USA
- Department of Conservative Dentistry; School of Dentistry; Complutense University; Madrid Spain
| | - O. A. Peters
- Department of Endodontics; Arthur A Dugoni School of Dentistry; University of the Pacific; San Francisco CA USA
| |
Collapse
|
43
|
Bayram HM, Bayram E, Ocak M, Uygun AD, Celik HH. Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro–computed Tomographic Study. J Endod 2017; 43:1166-1169. [DOI: 10.1016/j.joen.2017.02.005] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 02/01/2017] [Accepted: 02/12/2017] [Indexed: 11/15/2022]
|
44
|
Duque JA, Vivan RR, Cavenago BC, Amoroso-Silva PA, Bernardes RA, Vasconcelos BCD, Duarte MAH. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems. J Appl Oral Sci 2017; 25:27-33. [PMID: 28198973 PMCID: PMC5289397 DOI: 10.1590/1678-77572016-0230] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Accepted: 07/19/2016] [Indexed: 01/13/2023] Open
Abstract
Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn's tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.
Collapse
Affiliation(s)
- Jussaro Alves Duque
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru, SP, Brasil
| | - Rodrigo Ricci Vivan
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru, SP, Brasil
| | | | - Pablo Andrés Amoroso-Silva
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru, SP, Brasil
| | | | | | - Marco Antonio Hungaro Duarte
- Universidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos, Bauru, SP, Brasil
| |
Collapse
|
45
|
Comparison of Cyclic Fatigue Resistance of WaveOne and WaveOne Gold Small, Primary, and Large Instruments. J Endod 2017; 43:623-627. [DOI: 10.1016/j.joen.2016.11.021] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 11/21/2016] [Accepted: 11/24/2016] [Indexed: 11/19/2022]
|
46
|
Arias A, de Vasconcelos RA, Hernández A, Peters OA. Torsional Performance of ProTaper Gold Rotary Instruments during Shaping of Small Root Canals after 2 Different Glide Path Preparations. J Endod 2017; 43:447-451. [DOI: 10.1016/j.joen.2016.10.034] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 10/14/2016] [Accepted: 10/24/2016] [Indexed: 10/20/2022]
|
47
|
Plotino G, Grande NM, Mercadé Bellido M, Testarelli L, Gambarini G. Influence of Temperature on Cyclic Fatigue Resistance of ProTaper Gold and ProTaper Universal Rotary Files. J Endod 2017; 43:200-202. [DOI: 10.1016/j.joen.2016.10.014] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2016] [Accepted: 10/16/2016] [Indexed: 10/20/2022]
|
48
|
Evaluation of the Cyclic Fatigue and Torsional Resistance of Novel Nickel-Titanium Rotary Files with Various Alloy Properties. J Endod 2016; 42:1840-1843. [DOI: 10.1016/j.joen.2016.07.015] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 07/13/2016] [Accepted: 07/16/2016] [Indexed: 11/23/2022]
|
49
|
Silva EJNL, Tinoco JM, Tinoco EMB, Vieira VTL, Sassone LM, Lopes HP. Bending Resistance and Cyclic Fatigue Life of a new Single-File Reciprocating Instrument Waveone Gold. Eur Endod J 2016; 1:1-4. [PMID: 32566901 PMCID: PMC7299058 DOI: 10.5152/eej.2016.16018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 06/23/2016] [Accepted: 08/30/2016] [Indexed: 11/22/2022] Open
Abstract
Objective: The present study aimed to evaluate the bending resistance and cyclic fatigue fracture resistance of a new single-file reciprocating instrument called WaveOne Gold. Reciproc and WaveOne instruments were used as references for comparison. Methods: Sixty 25-mm NiTi instruments (Reciproc R25, WaveOne Primary and WaveOne Gold Primary) were tested. Flexibility was determined by applying 45° bending tests using a universal testing machine (n=10). A custom-made device was used during cyclic fatigue test (n=10), comprising a stainless steel artificial canal measuring 1.4 mm in diameter, 19 mm in total length with an 86° angle and 6 mm radius of curvature. Possible deformations at the helical shaft and mode of fracture were evaluated using scanning electron microscopy analysis. Statistical analysis was performed using one-way analysis of variance. Post hoc pair-wise comparisons were performed using Tukey’s test for multiple comparisons (P<0.05). Results: WaveOne presented significantly higher bending resistance than the other tested systems (P<0.05), whereas Reciproc presented the lowest bending resistance (P<0.05). Reciproc revealed a significantly longer cyclic fatigue fracture resistance than the other systems (P<0.05). Conclusion: Although WaveOne Gold presented higher flexibility than WaveOne, no differences in the resistance to fatigue were observed between both systems. The Reciproc files were more flexible and resistant to fatigue for the angle of curvature of 86° and 6 mm radius than WaveOne and WaveOne Gold files.
Collapse
Affiliation(s)
- Emmanuel João Nogueira Leal Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO) School of Dentistry, Rio de Janeiro, Brazil.,Department of Endodontics, Rio de Janeiro State University (UERJ) School of Dentistry, Rio de Janeiro, Brazil
| | - Justine Monnerat Tinoco
- Department of Endodontics, Rio de Janeiro State University (UERJ) School of Dentistry, Rio de Janeiro, Brazil
| | | | | | - Luciana Moura Sassone
- Department of Endodontics, Rio de Janeiro State University (UERJ) School of Dentistry, Rio de Janeiro, Brazil
| | - Hélio Pereira Lopes
- Department of Endodontics, Estácio de Sá University (UNESA) School of Dentistry, Rio de Janeiro, Brazil
| |
Collapse
|
50
|
Elnaghy AM, Elsaka SE. Mechanical properties of ProTaper Gold nickel-titanium rotary instruments. Int Endod J 2015; 49:1073-1078. [DOI: 10.1111/iej.12557] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Accepted: 09/24/2015] [Indexed: 11/27/2022]
Affiliation(s)
- A. M. Elnaghy
- Department of Endodontics; Mansoura University; Mansoura Egypt
| | - S. E. Elsaka
- Department of Dental Biomaterials; Faculty of Dentistry; Mansoura University; Mansoura Egypt
| |
Collapse
|