Aydın U, Özdemir M, Çulha E, Baştürk Özer MN, Turan B. Evaluation of Cyclic Fatigue Resistance of Novel Replica-Like Instruments in Static Test Model. Appl Bionics Biomech 2024; 2024:8842478. [PMID: 39206445 PMCID: PMC11357823 DOI: 10.1155/2024/8842478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Accepted: 08/06/2024] [Indexed: 09/04/2024] Open
Abstract
Introduction The aim of our study is to comparatively analyze the canal cyclic fatigue resistance of widely used rotary file systems, including EndoArt Touch Gold (ETG), Perfect MTF Plus Gold (PPG), Fanta V-Taper Gold (FVG), and ProTaper Next (PTN). Methods Stainless steel canals with a 60° angle and a 3-mm curvature radius were specially prepared. The canals were shaped with each rotary file system and tested for resistance using a cyclic fatigue testing apparatus. The number of fracture cycles (NFC; K file tip separation) was measured. Data were analysed by one-way ANOVA and post hoc LSD tests. Results PTN and PPG rotary file systems exhibited the highest NFC. The NFC value for PTN was 589 ± 63, and for PPG, it was 507 ± 51. Conclusion The results of this study demonstrate that rotary file systems such as PTN and PPG exhibit higher cyclic fatigue resistance. ETG and FVG rotary file systems also possess generally acceptable cyclic fatigue resistance levels.
Collapse
Affiliation(s)
- Uğur Aydın
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Melih Özdemir
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | - Emre Çulha
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| | | | - Bilal Turan
- Department of EndodonticsGaziantep University, Gaziantep, Türkiye
| |
Collapse
|
2
|
Srikumar GPV, Gadbail V, Alexander AK, Nishad G, Rahane S, Beautlin JS. An in vitro comparative evaluation of cyclic fatigue resistance of two rotary and two reciprocating file systems. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:774-779. [PMID: 39262602 PMCID: PMC11385906 DOI: 10.4103/jcde.jcde_2_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/11/2024] [Accepted: 06/10/2024] [Indexed: 09/13/2024]
Abstract
Context Root canal instrumentation is one of the important procedures for successful endodontic therapy. Unexpected fracture of files occurs during root canal instrumentation without any visible signs of deformation compromising the success of root canal treatment. Aims The aim of the study was to evaluate and compare cyclic fatigue resistance (CFR) of rotary and reciprocating files in simulated canals with 45°, 60°, and 90° angle of curvature. Settings and Design The study design was an In vitro study. Subjects and Methods Sixty nickel-titanium files, 30 each of rotary and reciprocating files were selected and divided into four groups (n = 15) of Neoendo Flex, ProTaper Next, WaveOne Gold (WOG), and Reciproc Blue (RPB) files. Each group was further subdivided into three subgroups containing five samples each based on their use in simulated canals with 45°, 60°, and 90° angle of curvature. To simulate root canals with 45°, 60°, and 90° angle of curvature, three artificial canals were designed in a stainless steel metal block. Each file was autoclaved, immersed in 3% sodium hypochlorite (NaOCl), and coated with 17% ethylenediaminetetraacetic acid (EDTA). Each file was tested for CFR using a torque-controlled reduction handpiece by instrumenting in a simulated canal for 10 s until fracture. The cycle of autoclaving, exposure to NaOCl, EDTA, and testing of CFR for 10 s per canal as per groups and subgroups was repeated again and again until the respective file fracture. The time taken to file fracture was recorded using a digital chronometer. The time taken for each file fracture (in minutes) was multiplied by the number of rotations per minute to attain the number of cycles to failure (NCF). Statistical Analysis Used The obtained results were subjected to statistical analysis using one-way analysis of variance and independent t-test. Results One-way ANOVA test showed a statistically significant difference between the four groups, P < 0.001. Independent "t"-test between individual subgroups showed a statistically significant difference, as P < 0.05. Conclusions WOG and RPB reciprocating file systems showed superior CFR, more especially in canals with abrupt 90° angle of curvature compared to both rotary file systems tested. Among rotary file systems tested, Neoendo Flex showed greater CFR than ProTaper Next.
Collapse
Affiliation(s)
- G P V Srikumar
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Vaishnavi Gadbail
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Arvind Kumar Alexander
- Department of Conservative Dentistry and Endodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India
| | - Geeta Nishad
- Department of Conservative Dentistry and Endodontics, Triveni Institute of Dental Sciences, Hospital and Research Centre, Bilaspur, Chhattisgarh, India
| | - Shripriya Rahane
- Department of Conservative Dentistry and Endodontics, Rajesh Ramdasji Kambe Dental College and Hospital, Akola, Maharashtra, India
| | - J S Beautlin
- Department of Conservative Dentistry and Endodontics, Rajas Dental College and Hospital, Tirunelveli, Tamil Nadu, India
| |
Collapse
|
3
|
Martins JNR, Silva EJNL, Marques D, Braz Fernandes FM, Versiani MA. Comprehensive Assessment of Cyclic Fatigue Strength in Five Multiple-File Nickel-Titanium Endodontic Systems. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2345. [PMID: 38793413 PMCID: PMC11123240 DOI: 10.3390/ma17102345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/02/2024] [Accepted: 05/09/2024] [Indexed: 05/26/2024]
Abstract
The resistance of nickel-titanium endodontic instruments against cyclic fatigue failure remains a significant concern in clinical settings. This study aimed to assess the cyclic fatigue strength of five nickel-titanium rotary systems, while correlating the results with the instruments' geometric and metallurgical characteristics. A total of 250 new instruments (sizes S1/A1, S2/A2, F1/B1, F2/B2, F3/B3) from ProTaper Gold, ProTaper Universal, Premium Taper Gold, Go-Taper Flex, and U-Files systems underwent mechanical testing. Prior to experimental procedures, all instruments were meticulously inspected to identify irregularities that could affect the investigation. Using a stereomicroscope, design characteristics such as the number of spirals, length, spirals per millimeter, and average helical angle of the active blade were determined. The surface finishing characteristics of the instruments were examined using a scanning electron microscope. Differential scanning calorimetry was employed to establish the instruments' phase transformation temperatures, while energy-dispersive X-ray spectroscopy was utilized to analyze the elemental composition of the alloy. The instruments were subjected to cyclic fatigue testing within a stainless steel non-tapered artificial canal featuring a 6 mm radius and 86 degrees of curvature. Appropriate statistical tests were applied to compare groups, considering a significance level of 0.05. The assessed design characteristics varied depending on the instrument type. The least irregular surface finishing was observed in U-Files and Premium Taper Gold files, while the most irregular surface was noted in Go-Taper Flex. All instruments exhibited near-equiatomic proportions of nickel and titanium elements, whereas ProTaper Universal and U-Files instruments demonstrated lower phase transformation temperatures compared to their counterparts. Larger-sized instruments, as well as ProTaper Universal and U-Files, tended to display lower cyclic fatigue strength results. Overall, the design, metallurgical, and cyclic fatigue outcomes varied among instruments and systems. Understanding these outcomes may assist clinicians in making more informed decisions regarding instrument selection.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Emmanuel J. N. L. Silva
- Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
- Department of Endodontics, Fluminense Federal University, Rio de Janeiro 24220-900, Brazil
- Department of Endodontics, Rio de Janeiro University (UERJ), Rio de Janeiro 20550-013, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral (GIBBO), Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), 1600-277 Lisboa, Portugal
- Centro de Estudos de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
| | - Francisco M. Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal
| | - Marco A. Versiani
- Dental Specialty Center, Brazilian Military Police, Belo Horizonte 30350-190, Brazil
| |
Collapse
|
4
|
Hamid T, Malik A, Kumar A, Anjum S. Comparative evaluation of cyclic fatigue resistance of thermomechanically treated NiTi rotary instruments in simulated curved canals with two different radii of curvature: An in vitro Study. JOURNAL OF CONSERVATIVE DENTISTRY AND ENDODONTICS 2024; 27:393-399. [PMID: 38779209 PMCID: PMC11108414 DOI: 10.4103/jcde.jcde_32_24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 02/23/2024] [Accepted: 02/26/2024] [Indexed: 05/25/2024]
Abstract
Background This study aimed to compare the effect of heat treatment on the cyclic fatigue resistance of three different nickel-titanium rotary file systems: TruNatomy, HyFlex CM, and NeoEndo flex in simulated curved canals at two different radii of curvatures. Materials and Methods A total of 60 NiTi rotary files of three types were used, and the samples were divided into three groups TruNatomy, HyFlex CM, and NeoEndo flex. All the instruments were subjected to cyclic fatigue testing using a stainless steel custom-made canal model with a 60° angle of curvature and two radii of curvature 5 mm and 3 mm; the number of cycles to fracture and length of the fractured segment was measured. The separated instruments were subjected to fractographic analysis under scanning electron microscope. Results The number of cycles to failure to fracture a file at a 3 mm radius of curvature is significantly less as compared to a 5 mm radius of curvature (HCM > TRN > NE). Conclusion Within the limitation of the present study, there was a positive correlation between the radius of curvature and fatigue life of NiTi files.
Collapse
Affiliation(s)
- Tahira Hamid
- Department of Conservative Dentistry and Endodontics, Indira Gandhi Government Dental College, Jammu, Jammu and Kashmir, India
| | - Azhar Malik
- Department of Conservative Dentistry and Endodontics, Indira Gandhi Government Dental College, Jammu, Jammu and Kashmir, India
| | - Ajay Kumar
- Department of Conservative Dentistry and Endodontics, Indira Gandhi Government Dental College, Jammu, Jammu and Kashmir, India
| | - Shamim Anjum
- Department of Conservative Dentistry and Endodontics, Indira Gandhi Government Dental College, Jammu, Jammu and Kashmir, India
| |
Collapse
|
5
|
Bürklein S, Maßmann P, Schäfer E, Donnermeyer D. Cyclic Fatigue of Different Reciprocating Endodontic Instruments Using Matching Artificial Root Canals at Body Temperature In Vitro. MATERIALS (BASEL, SWITZERLAND) 2024; 17:827. [PMID: 38399077 PMCID: PMC10890344 DOI: 10.3390/ma17040827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/05/2024] [Accepted: 02/07/2024] [Indexed: 02/25/2024]
Abstract
Reciprocating motion expands the lifetime of endodontic instruments during the preparation of severely curved root canals. This study aimed to investigate the time to fracture (TTF) and number of cycles to failure (NCF) of different reciprocating instruments (n = 20 in each group) at body temperature using a dynamic testing model (amplitude = 3 mm). Reciproc Blue (RPB), size 25/.08, WaveOne Gold (WOG) 25/.07, Procodile (Proc) 25/.06, R-Motion (RM_06) 25/.06 and R-Motion (RM_04) 30/.04 instruments were tested in their specific reciprocating motion in artificial matching root canals (size of the instrument ± 0.02 mm; angle of curvature 60°, radius 5.0 mm, and centre of curvature 5.0 mm from apical endpoint). The number of fractured instruments, TTF, NCF, the and lengths of the fractured instruments were recorded and statistically analysed using the Chi-Square or Kruskal-Wallis test. Both TTF (median 720, 643, 562, 406, 254 s) and the NCF (3600, 3215, 2810, 2032, 1482 cycles) decreased in the following order RM_06 > RPB > RM_04 > Proc > WOG with partially significant differences. During testing, only six RM_06 instruments fractured, whereas 16/20 (RPB), 18/20 (Proc), and 20/20 (RM_04, WOG) fractures were recorded (p < 0.05). Within the limitations of the present study, blue-coloured RPB and RM instruments exhibited a significantly superior cyclic fatigue resistance compared to SE-NiTi and Gold-wire instruments. Heat treatment, cross-sectional design and core mass significantly influenced the longevity of reciprocating instruments in cyclic dynamic testing.
Collapse
Affiliation(s)
- Sebastian Bürklein
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - Paul Maßmann
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - Edgar Schäfer
- Central Interdisciplinary Ambulance in the School of Dentistry, University of Münster, 48149 Münster, Germany; (S.B.); (P.M.); (E.S.)
| | - David Donnermeyer
- Department of Periodontology and Operative Dentistry, University of Münster, 48149 Münster, Germany
| |
Collapse
|
6
|
Pedullà E, Carlesi T, Pappalardo A, Canova FS, Malagnino VA, La Rosa GRM, Generali L. Impact of pecking amplitude on cyclic fatigue of new nickel-titanium files. Clin Exp Dent Res 2024; 10:e811. [PMID: 38053521 PMCID: PMC10860459 DOI: 10.1002/cre2.811] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/31/2023] [Accepted: 11/05/2023] [Indexed: 12/07/2023] Open
Abstract
OBJECTIVES The aim of this study is to determine the cyclic fatigue resistance of Mtwo Minimal in static and dynamic tests, with different amplitudes of pecking movements, at intracanal temperature. MATERIALS AND METHODS Two hundred new 25-mm Mtwo Minimal rotary files (#10/0.035, #17.5/0.045, #25/0.05, #40/0.03, #45/0.03) were tested in static and dynamic cyclic fatigue tests at 35°C (±1°C). An artificial stainless-steel canal was used. In the dynamic mode, axial movements were set at 1 and 3 mm. The number of cycles to fracture (NCF) was recorded and statistically analyzed by one-way analysis of variance (p < 0.05). RESULTS The 3-mm dynamic test showed significantly increased NCF than the other tests for the #10/0.035, #17.5/0.045, and #25/0.05 files (p < 0.05). The #40/0.03 and #45/0.03 files showed no significant differences in all the tests (p > 0.05). CONCLUSION Mtwo Minimal showed higher cyclic fatigue resistance in the dynamic test than the static test, except for the larger instruments. The 3-mm pecking amplitude increased the cyclic fatigue resistance of the smaller instruments.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical‐Surgical SpecialtiesUniversity of CataniaCataniaItaly
| | - Teocrito Carlesi
- Department of Medical, Oral and Biotechnological Sciences, Faculty of Medicine and SurgeryUniversity of Chieti—Pescara “G. D'Annunzio”ChietiItaly
- Department of Innovative Technologies in Medicine and Dentistry, Faculty of Medicine and SurgeryUniversity of Chieti—Pescara “G. D'Annunzio”ChietiItaly
| | | | | | - Vito Antonio Malagnino
- Department of Innovative Technologies in Medicine and Dentistry, Faculty of Medicine and SurgeryUniversity of Chieti—Pescara “G. D'Annunzio”ChietiItaly
| | | | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine RelevanceUniversity of Modena and Reggio EmiliaModenaItaly
| |
Collapse
|
7
|
Dos Reis FAS, Abu Hasna A, Ragozzini G, de Moura FB, Campos TMB, de Martin AS, Carvalho CAT, Bueno CES. Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue. Sci Rep 2023; 13:22956. [PMID: 38151487 PMCID: PMC10752872 DOI: 10.1038/s41598-023-50096-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 12/15/2023] [Indexed: 12/29/2023] Open
Abstract
This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey's test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.
Collapse
Affiliation(s)
| | - Amjad Abu Hasna
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil.
- School of Dentistry, Universidad Espíritu Santo, Samborondón, Ecuador.
| | - Gustavo Ragozzini
- Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Endodontia, Campinas, SP, Brazil
| | - Felipe Bernardo de Moura
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil
| | | | | | - Cláudio Antonio Talge Carvalho
- Department of Restorative Dentistry, Endodontics Division, Institute of Science and Technology, São Paulo State University (UNESP), Av. Eng. Francisco José Longo Avenue 777, São José dos Campos, SP, CEP 12245-000, Brazil
| | | |
Collapse
|
8
|
dos Reis FAS, Abu Hasna A, Ragozzini G, de Moura FB, Campos TMB, de Martin AS, Carvalho CAT, Bueno CES. Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue. Sci Rep 2023; 13:22956. [DOI: https:/doi.org/10.1038/s41598-023-50096-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 12/15/2023] [Indexed: 01/17/2024] Open
Abstract
AbstractThis study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey’s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (p < 0.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.
Collapse
|
9
|
La Rosa GRM, Leotta ML, Canova FS, Romeo VR, Cervino G, Generali L, Pedullà E. Cyclic fatigue resistance of different nickel-titanium instruments in single and double curvature at room and body temperatures: A laboratory study. AUST ENDOD J 2023; 49:592-598. [PMID: 37592880 DOI: 10.1111/aej.12789] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 08/07/2023] [Indexed: 08/19/2023]
Abstract
The aim of this study was to compare the cyclic fatigue resistance of nickel-titanium instruments inside single and double-curved canals at different temperatures. 160 HyFlex EDM #20.05 (HEDM), VDW.ROTATE #20.05 and #25.06, Mtwo #25.06 were randomised (n = 10) for the dynamic cyclic fatigue tests according to the curvature (i.e. single and double) at 20° ± 1°C and 35° ± 1°C. The number of cycles to fracture (NCF) was analysed by two-way ANOVA with p < 0.05. Fatigue resistance of all instruments significantly decreased at body temperature in single and double curvatures, except for HEDM in double curvature. The NCF was significantly lower in double curvature than single at both temperatures for all files, except for VDW.ROTATE #20.05 at 35° ± 1°C. Within the study limitations, temperature significantly impaired cyclic fatigue resistance of all files except HEDM #20.05 in double curvature. Similarly, double curvature had a detrimental effect on cyclic fatigue resistance of all files except for VDW.ROTATE #20.05 at body temperature.
Collapse
Affiliation(s)
- Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Maria Laura Leotta
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Francesco Saverio Canova
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Virginia Rosy Romeo
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Gabriele Cervino
- Department of Biomedical and Dental Sciences and Morphological and Functional Imaging, Messina University, Messina, Italy
| | - Luigi Generali
- Department of Surgery, Medicine, Dentistry and Morphological Sciences with Transplant Surgery, Oncology and Regenerative Medicine Relevance (CHIMOMO), University of Modena and Reggio Emilia, Modena, Italy
| | - Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| |
Collapse
|
10
|
Martins JNR, Silva EJNL, Marques D, Pinto R, Francisco H, Ajuz N, Rito Pereira M, Braz Fernandes FM, Versiani MA. Characterization of four heat-treated reciprocating instruments: Design, metallurgy, mechanical performance, and irrigation flow patterns. Int Endod J 2023; 56:1412-1428. [PMID: 37698946 DOI: 10.1111/iej.13971] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/21/2023] [Accepted: 08/23/2023] [Indexed: 09/14/2023]
Abstract
AIM To compare the design, metallurgy, and mechanical properties of four heat-treated reciprocating instruments coupled with the evaluation of the irrigation flow using an in silico model. METHODOLOGY New EdgeOne Fire Primary, Easy-File Flex Regular 25, WaveOne Gold Primary and Reciproc Blue R25 instruments (n = 124) were initially evaluated regarding their design through stereomicroscopy, scanning electron microscopy and 3D surface scanning. In addition, energy-dispersive X-ray spectroscopy was utilized to determine their elemental composition, and differential scanning calorimetry tests to evaluate their phase transformation temperatures. Their mechanical performance was further assessed through torsional and bending tests. Using scans obtained from a real tooth and the instruments, a computational fluid dynamics assessment was conducted to determine the irrigation flow pattern, apical pressure, and wall shear stress in simulated canal preparation. Mood's median and One-way anova post hoc Tukey tests were used for statistical comparisons (α = 5%). RESULTS Reciproc Blue exhibited a superior number of blades (n = 8), whereas EdgeOne Fire had the highest overall volume (4.38 mm3 ) and surface area (32.32 mm2 ). At the 3-mm axial level, EdgeOne Fire displayed the lowest core diameter (0.13 mm), while Reciproc Blue had the highest (0.16 mm). All blades were symmetrical, and the tips of the instruments were non-active but differed from each other. The most irregular surfaces were observed in EdgeOne Fire and Easy-File Flex. All instruments were manufactured from nickel-titanium alloys and exhibited distinct phase transformation temperatures. WaveOne Gold and Reciproc Blue demonstrated the highest maximum torque values (1.87 and 1.62 N cm, respectively), while the lowest was observed on EdgeOne Fire (1.21 N cm) (p < .05). The most flexible (p < .05) were EdgeOne Fire (angle of rotation: 602.6°; maximum bending load: 251.4 g.f) and Reciproc Blue (533.2° and 235.6 g.f). There were no significant differences observed in the irrigation flow among the four domains generated by the tested instruments. CONCLUSIONS Despite observing variations in the design, phase transformation temperatures, and in the torsional and bending test outcomes among the four heat-treated reciprocating instruments, no significant differences were found in the irrigation flow pattern among the different groups in the simulated root canal preparations.
Collapse
Affiliation(s)
- Jorge N R Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE)-Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
| | - Emmanuel João Nogueira Leal Silva
- School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
- Fluminense Federal University, Rio de Janeiro, Brazil
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE)-Cochrane Portugal, Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, Lisboa, Portugal
| | - Ricardo Pinto
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Grupo de Investigação em Bioquimica e Biologia Oral, Unidade de Investigação em Ciências Orais e Biomédicas (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
| | - Helena Francisco
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
- Instituto de Implantologia, Lisboa, Portugal
- Grupo de Investigação Implantologia e Regeneração Óssea (UICOB), Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Natasha Ajuz
- School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - Mário Rito Pereira
- Faculdade de Medicina Dentária, Universidade de Lisboa, Lisboa, Portugal
| | - Francisco Manuel Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, Caparica, Portugal
| | | |
Collapse
|
11
|
Kasuga Y, Kimura S, Maki K, Unno H, Omori S, Hirano K, Ebihara A, Okiji T. Phase transformation and mechanical properties of heat-treated nickel-titanium rotary endodontic instruments at room and body temperatures. BMC Oral Health 2023; 23:825. [PMID: 37904159 PMCID: PMC10614384 DOI: 10.1186/s12903-023-03550-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 10/18/2023] [Indexed: 11/01/2023] Open
Abstract
BACKGROUND The aim of this study was to evaluate the phase composition, phase transformation temperatures, bending property, and cyclic fatigue resistance of different heat-treated nickel-titanium (NiTi) rotary instruments with the same tip diameter and taper at room (RT; 25 ± 1 °C) and body (BT; 37 ± 1 °C) temperatures. METHODS Five heat-treated NiTi rotary instruments, HyFlex EDM (EDM), HyFlex CM (CM), Vortex Blue (VB), RE file CT (RE) and JIZAI, and a non-heat-treated NiTi rotary instrument (Mtwo) with a size 40, 0.04 taper were investigated. Temperature-dependent phase transformation was examined with differential scanning calorimetry (DSC). The bending loads of the instruments at RT and BT were evaluated using a cantilever-bending test. Cyclic fatigue resistance at RT and BT was measured using a dynamic test, during which the instruments were rotated in combination with a 2-mm back-and-forth motion in an artificial curved canal, and the number of cycles to failure (NCF) was determined. The results were analyzed using two-way repeated measures analysis of variance, a simple main effect test, and the Bonferroni test (α = 0.05). RESULTS DSC results indicated that EDM and Mtwo were primarily composed of martensite/R-phase and austenite, respectively, while the other heat-treated instruments were composed of a mix of martensite/R-phase and austenite at the tested temperatures. Regardless of the temperature setting, the bending loads of heat-treated instruments were significantly lower than those of Mtwo (p < 0.05). EDM showed the lowest bending loads and highest NCF at both temperatures (p < 0.05). CM, VB, and JIZAI showed significantly higher bending loads at BT than at RT (p < 0.05). The NCF of all the heat-treated instruments, except VB, was lower at BT than at RT (p < 0.05). At BT, the NCF of CM, VB, RE, and JIZAI were not significantly higher than that of Mtwo (p > 0.05). CONCLUSIONS Heat-treated NiTi instruments exhibited lower bending loads and higher NCF values than Mtwo. However, this tendency was less pronounced at BT than at RT, especially in the NCF values of instruments with a mixture of martensite/R-phase and austenite phases at the tested temperatures.
Collapse
Affiliation(s)
- Yuka Kasuga
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Shunsuke Kimura
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan.
| | - Keiichiro Maki
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Hayate Unno
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Satoshi Omori
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Keiko Hirano
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Arata Ebihara
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| | - Takashi Okiji
- Department of Pulp Biology and Endodontics, Division of Oral Health Sciences, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8549, Japan
| |
Collapse
|
12
|
Monteiro-Netto RDC, Braambati D, Arruda-Vasconcelos R, Soares ADJ, Frozoni M. Evaluation of the rotary kinematics between actual and set speeds of X-Smart Plus, VDW.Silver and iRoot motors. Braz Dent J 2023; 34:21-26. [PMID: 37194853 DOI: 10.1590/0103-6440202304953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Accepted: 02/01/2023] [Indexed: 05/18/2023] Open
Abstract
The present study evaluated the actual rotational speed of three different endodontic motors compared to the values provided by the manufacturers. A total of three endodontic motors (X-Smart Plus, VDW.Silver, and iRoot) were tested at 400 rpm and 800 rpm and 2 N/cm2 torque. The kinematics of the devices was recorded by using a custom angle-measuring disc with a 50-mm diameter attached to the handpiece provided by the manufacturer, whereas their movement was captured by a high-speed camera at 2,400 frames per second, 800 x 800 pixel-resolution and distance of 0.3 m from the target object. Statistical analysis was performed at a significance level of 5%. At 400 rpm, the iRoot motor had a value of 17.94 rpm above that indicated by the manufacturer, which was significantly different from those of X-Smart Plus (5.20 rpm below that indicated by the manufacturer) and VDW.Silver (0.62 rpm above that indicated by the manufacturer) motors (P < 0.05). At 800 rpm, the iRoot motor had a value of 51.34 rpm below that indicated by the manufacturer, whereas the X-Smart Plus motor had a value of 13.00 rpm below that indicated by the manufacturer (P > 0.05). The VDW.Silver motor statistically differed from the iRoot and X-Smart Plus ones, showing a value of 1.68 rpm above that indicated by the manufacturer. In conclusion, the X-Smart Plus, VDW.Silver, and iRoot motors showed lower variations in the rotational speed values compared to those reported by their manufacturers. The endodontic motors presented different behaviors between them, with the VDW.Silver motor presents the most accurate values and the iRoot presents the most divergent values.
Collapse
Affiliation(s)
- Renata de Castro Monteiro-Netto
- Department of Restorative Dentistry, Division of Endodontics, São Leopoldo Mandic Dental School, Campinas, São Paulo, Brazil
| | - Dieimes Braambati
- Department of Restorative Dentistry, Division of Endodontics, São Leopoldo Mandic Dental School, Campinas, São Paulo, Brazil
| | - Rodrigo Arruda-Vasconcelos
- Department of Restorative Dentistry, Division of Endodontics, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Adriana de-Jesus Soares
- Department of Restorative Dentistry, Division of Endodontics, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Marcos Frozoni
- Department of Restorative Dentistry, Division of Endodontics, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| |
Collapse
|
13
|
SÜRME K, AKMAN H, BÜYÜKÖZER ÖZKAN H, ER K. Kullanılmış ve yeni Revo-S nikel titanyum eğelerin döngüsel yorgunluk dirençlerinin karşılaştırılması. ACTA ODONTOLOGICA TURCICA 2023. [DOI: 10.17214/gaziaot.1035204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Amaç: Bu çalışmanın amacı, yapay kanallar kullanılarak yeni ve kullanılmış Revo-S nikel titanyum döner eğe sisteminin döngüsel yorgunluk (DY) dirençlerinin karşılaştırılmasıdır.
Gereç ve Yöntem: Her gruptan 12 adet olmak üzere toplam 72 adet yeni ve 2 defa klinikte kullanılmış Revo-S SC1 (25/.06), Revo-S SC2 (25/.04) ve Revo-S SU (25/.06) eğeler çalışmaya dahil edildi. DY direnci testleri için iç çapı 1.5 mm olan, 60° eğrilik açısı ve 5 mm eğrilik yarıçapına sahip olan kavisli bir yapay kanal içeren paslanmaz çelik blok kullanıldı. Deney sistemi distile su ile dolduruldu ve ortam sıcaklığı 35 ± 1 °C sıcaklıkta sabit tutuldu. Eğeler kırılma gerçekleşene kadar yapay kanal içinde çalıştırıldı. Her eğe için kırılma gerçekleşene kadar geçen süre kronometre ile kaydedildi ve eğelerin kırılıncaya kadar yaptıkları tur sayısı hesaplandı. Elde edilen veriler tek yönlü varyans analizi ve post-hoc Tukey testi kullanılarak değerlendirildi.
Bulgular: Eğelerin kırılıncaya kadar yaptığı ortalama tur sayısı en yüksek yeni SC2 eğe grubunda (912.3 ± 76.8), en düşük ise kullanılmış SU eğe grubunda (204.2 ± 59.6) bulundu. SC1 ve SC2 eğeler için yeni ve kullanılmış eğeler arasında DY direnci açısından istatistiksel olarak anlamlı bir fark gözlenmez iken (p>0.05), SU eğe grubunda anlamlı bir fark bulundu (p<0.05).
Sonuç: Çalışmamızın sınırlamaları dahilinde; klinik kullanım sonrasında tüm eğelerin DY direncinde azalma olduğu ancak bu azalmanın sadece SU eğe grubunda önemli olduğu bulundu.
Collapse
Affiliation(s)
- Koray SÜRME
- ALANYA ALAADDIN KEYKUBAT UNIVERSITY, FACULTY OF DENTISTRY
| | - Hayri AKMAN
- ALANYA ALAADDİN KEYKUBAT ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR
| | | | - Kürşat ER
- AKDENİZ ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, DİŞ HEKİMLİĞİ PR
| |
Collapse
|
14
|
Al-Amidi AH, Al-Gharrawi HAR. Effect of autoclave sterilization on the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-one nickel-titanium endodontic instruments. J Conserv Dent 2023; 26:26-30. [PMID: 36908740 PMCID: PMC10003289 DOI: 10.4103/jcd.jcd_611_21] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 01/23/2022] [Accepted: 01/30/2022] [Indexed: 11/04/2022] Open
Abstract
Background Rotary nickel-titanium files have become the most commonly used engine-powered endodontic instruments due to their improvement in fatigue resistance and flexibility. The autoclaving is the most commonly used method for sterilization. However, the risk of instrument fracture, mainly due to cyclic fatigue during rotation within a curved canal, is still a matter of critical concern. Aims This study aimed to measure and compares the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-One files in a single curved simulated canal before and after autoclave sterilization. Materials and Methods Twenty-four files each of EdgeFile X7, 2Shape, and F-One files were used in this study. They were grouped as group A: EdgeFile X7, group B: 2Shape, and group C: F-One files. Then, each group was subdivided into two, sterilized and nonsterilized, subgroups. The files were tested using a custom-made artificial canal. The number of cycles to fracture (NCF) was calculated. Statistical Analysis Used One-way analysis of variance, post hoc Tukey's test, and independent t-test were used. Results In nonsterilized instruments, the NCF of the EdgeFile X7 group was significantly higher than that in the other groups (P < 0.05). In sterilized instruments, there was a nonsignificant difference in NCF between EdgeFile X7 and F-One files (P > 0.05). The NCF of 2Shape was significantly lower than other files (P ≤ 0.05) in sterilized and nonsterilized groups. The autoclaving significantly decreased (P ≤ 0.05) the cyclic fatigue resistance of the tested files. Conclusions EdgeFile X7 was the most fatigue resistant. Autoclaving reduced the cyclic fatigue resistance of the tested files.
Collapse
Affiliation(s)
- Arkan H. Al-Amidi
- Alkarkh Health Directorate Baghdad, Ministry of Health, Baghdad, Iraq
| | | |
Collapse
|
15
|
Thu M, Ebihara A, Maki K, Nishijo M, Kimura S, Nakatsukasa T, Kyaw MS, Okiji T. Effect of different axial speed patterns on cyclic fatigue resistance of rotary nickel-titanium instruments. BMC Oral Health 2022; 22:617. [PMID: 36529721 PMCID: PMC9761994 DOI: 10.1186/s12903-022-02639-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Accepted: 11/30/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND To evaluate the effect of pecking motions with faster upward speed on the dynamic cyclic fatigue resistance of nickel-titanium rotary instruments with different metallurgy. METHODS Forty each of ProTaper Universal F3 (PTU) and ProTaper Gold F3 (PTG) instruments (size #30/.09) were equally divided into four groups. The test was performed using an 18-mm-long stainless steel artificial canal with a 5-mm radius of curvature, a 45° canal curvature and a 2-mm canal diameter. A downward speed of 100 mm/min was employed, while the upward speed was set at 100, 150, 200 or 300 mm/min. Time to failure (Tf), number of cycles to failure (Nf) and number of pecking motions to failure (Np) were recorded. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests for Tf, Nf, and Np (α = 0.05). RESULTS The 100/300 mm/min group showed significantly higher Np values than the 100/100 mm/min group (p < 0.05), whereas there were no significant differences in Tf and Nf among the tested speed groups (p < 0.05) in either PTU or PTG. PTG exhibited significantly higher Tf, Nf, and Np than PTU (p < 0.05). CONCLUSIONS Under the tested conditions, the fastest upward speed group showed significantly higher cyclic fatigue resistance, as demonstrated by larger Np, than the same speed group. PTG had significantly higher cyclic fatigue resistance than PTU in all groups.
Collapse
Affiliation(s)
- Myint Thu
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Arata Ebihara
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Keiichiro Maki
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Miki Nishijo
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Shunsuke Kimura
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Taro Nakatsukasa
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Moe Sandar Kyaw
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| | - Takashi Okiji
- grid.265073.50000 0001 1014 9130Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 5-45, Yushima 1-chome, Bunkyo-ku, Tokyo, 113-8549 Japan
| |
Collapse
|
16
|
Influence of different heat treatments and temperatures on the cyclic fatigue resistance of endodontic instruments with the same design. Clin Oral Investig 2022; 27:1793-1798. [PMID: 36454355 DOI: 10.1007/s00784-022-04808-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 11/27/2022] [Indexed: 12/04/2022]
Abstract
OBJECTIVES To evaluate the influence of different heat treatments and temperatures on the cyclic fatigue resistance of 2Shape instruments (Micro Mega, Besancon, France) with the same design. MATERIALS AND METHODS A total of 80 2Shape TS1 (#25/.04) and 80 TS2 (#25/.06) files with different heat treatments (no heat-treated, NHT; C-Wire; T-Wire; CM-Wire) were tested at room (25° ± 1 °C) and body (37° ± 1 °C) temperatures in 16-mm stainless steel artificial canal with a curvature of 60° and 5 mm of radius. Files were tested in continuous rotation at 300 rpm using a customized device. Cyclic fatigue resistance was expressed in the number of cyclic to fracture (NCF). The phase transformation temperature of each file was determined by differential scanning calorimetry. Data were statistically analyzed using the two-way ANOVA and the Bonferroni post-hoc test with p < 0.05. RESULTS All CM-Wire TS1 and TS2 files showed higher NCF than the other groups at both temperatures (p < 0.001). C-Wire TS2 showed higher resistance than NHT and T-Wire TS2 (p < 0.001), with no significant differences between the last two. Body temperature significantly decreased NCF of all tested files (p < 0.05) except for NHT and T-Wire TS1. CONCLUSIONS Body temperature negatively affected the cyclic fatigue resistance of C-Wire and CM-Wire TS1 and of all TS2 files compared with room temperature. The CM-Wire instruments exhibited the highest cyclic fatigue resistance of all tested files. CLINICAL RELEVANCE Heat-treated nickel-titanium files can differently perform according to environmental temperature and file dimensions. The CM-Wire 2Shape prototypes displayed the highest flexural resistance in all experimental conditions.
Collapse
|
17
|
Unno H, Ebihara A, Hirano K, Kasuga Y, Omori S, Nakatsukasa T, Kimura S, Maki K, Okiji T. Mechanical Properties and Root Canal Shaping Ability of a Nickel-Titanium Rotary System for Minimally Invasive Endodontic Treatment: A Comparative In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7929. [PMID: 36431416 PMCID: PMC9692467 DOI: 10.3390/ma15227929] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/02/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
Selection of an appropriate nickel−titanium (NiTi) rotary system is important for minimally invasive endodontic treatment, which aims to preserve as much root canal dentin as possible. This study aimed to evaluate selected mechanical properties and the root canal shaping ability of TruNatomy (TRN), a NiTi rotary system designed for minimally invasive endodontic shaping, in comparison with existing instruments: HyFlex EDM (HEDM), ProTaper Next (PTN), and WaveOne Gold (WOG). Load values measured with a cantilever bending test were ranked as TRN < HEDM < WOG < PTN (p < 0.05). A dynamic cyclic fatigue test revealed that the number of cycles to fracture was ranked as HEDM > WOG > TRN > PTN (p < 0.05). Torque and vertical force generated during instrumentation of J-shaped artificial resin canals were measured using an automated instrumentation device connected to a torque and vertical force measuring system; TRN exhibited smaller torque and vertical force values in most comparisons with the other instruments. The canal centering ratio for TRN was smaller than or comparable to that for the other instruments except for WOG at the apex level. Under the present experimental conditions, TRN showed higher flexibility and lower torque and vertical force values than the other instruments.
Collapse
|
18
|
Pedullà E, Kharouf N, Caruso S, La Rosa GRM, Jmal H, Haikel Y, Mancino D. Torsional, Static and Dynamic Cyclic Fatigue Resistance of Reciprocating and Continuous Rotating NiTi Instruments. J Endod 2022; 48:1421-1427. [PMID: 35987386 DOI: 10.1016/j.joen.2022.08.005] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 07/14/2022] [Accepted: 08/10/2022] [Indexed: 11/17/2022]
Abstract
INTRODUCTION To evaluate torsional, dynamic and static cyclic fatigue resistance of the reciprocating One Reci (OR, Micromega, Besançon, France), WaveOne Gold (WOG, Dentsply Maillefer, Ballaigues, Switzerland), rotary One Curve (OC, MicroMega, Besançon, France) and ProTaper Next X2 (PTN X2, Dentsply Sirona, Ballaigues, Switzerland) instruments. METHODS A total of 120 NiTi instruments (n = 30) OR, WOG, OC and PTN X2 were used. Torque and rotation angle until failure under static torsion loading were measured according to the ISO 3630-1. Static and dynamic fatigue resistance was measured as the time to fracture (TTF) in an artificial stainless-steel canal with a 60° angle and 5-mm radius of curvature at intracanal temperature. The results were analyzed with one-way ANOVA and post-hoc Tukey tests. The alpha-type error was set at 5%. Fracture instruments from torsion and fatigue tests were examined with scanning electron microscope. RESULTS The OR showed higher static fatigue resistance and rotation angle at fracture than the WOG, OC and PTN X2 (P < .05). The WOG exhibited higher torsional resistance than the others (P < .05). Dynamic cyclic fatigue resistance tests had highest TTF than static for the PTN X2 and the WOG groups (P < .05). In the dynamic tests, the OR and WOG showed higher TTF than the OC and PTN X2 (P < .05). CONCLUSIONS Under these experimental condition, One Reci exhibited suitable mechanical properties with the highest cyclic fatigue resistance and angle of rotation among the tested instruments.
Collapse
Affiliation(s)
- Eugenio Pedullà
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy.
| | - Naji Kharouf
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Simone Caruso
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Giusy Rita Maria La Rosa
- Department of General Surgery and Medical-Surgical Specialties, University of Catania, Catania, Italy
| | - Hamdi Jmal
- ICube Laboratory, UMR 7357 CNRS, Mechanics Department, University of Strasbourg, Strasbourg, France
| | - Youssef Haikel
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| | - Davide Mancino
- Department of Bioengineering and Biomaterials, INSERM (French National Institute of Health and Medical Research) 1121, University of Strasbourg, Strasbourg, France; Department of Endodontics, Faculty of Dental Medicine, University of Strasbourg, Strasbourg, France
| |
Collapse
|
19
|
What meaningful information are the instruments mechanical testing giving us? A comprehensive review. J Endod 2022; 48:985-1004. [PMID: 35667567 DOI: 10.1016/j.joen.2022.05.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 04/21/2022] [Accepted: 05/26/2022] [Indexed: 11/22/2022]
Abstract
Instruments mechanical strength and flexibility are traditionally tested by running cyclic fatigue, torsional, bending, buckling and microhardness tests. Several cyclic fatigue test models have been used in endodontics, all capable of providing a curved trajectory for the instrument to rotate. The cyclic fatigue testing allowed to identify conditions that may affect the fatigue strength outcomes, such as canal radius and degree of curvature, handpiece static vs dynamic motions, test temperature, kinematics, instrument previously wear and sterilization cycles, or instrument's size and metal alloy features. Due to the international test specifications for both torsional and bending tests, the variations of their models are not as many as for cyclic fatigue. These tests have also identified conditions capable of affecting the outcomes, such as kinematics, instrument's preloading, cross-sectional diameters, or alloy heat treatments. Buckling and microhardness are less common, with the metal alloy being considered to have a major influence on the results. Instruments mechanical testing, having all these individual conditions as independent variables, allowed to understand them and moulded the way the technical procedures are performed clinically. Even though the artificiality and simplicity of these tests will hardly mimic real working situations, and independently of being capable of producing cornerstone knowledge, these tests are also associated with inconsistency, lack of reproducibility and low external validity. Several attempts have been made to increase the generalizability of the outcomes by adding test settings that intend to mimic the clinical condition. Although pertinent, these settings may also add variabilities inherent to their concepts and practical applications in the laboratory environment. Although the actual studies should be seen as laboratory mechanical tests that measure very specific parameters under very particular conditions and that by far do not mimic the clinical condition, the lower validity drawback seems to be possible to be minimized when achieving a comprehensive understanding of the instrument behaviour. A Finite Elements Method and/or a multimethod research approach may lead to superior data collection, analysis, and results' interpretation, which when associated with a reliable confounding factors control and proper study designs may be helpful tools and strategies in order to increase the reliability of the outcomes.
Collapse
|
20
|
Basturk FB, Özyürek T, Uslu G, Gündoğar M. Mechanical Properties of the New Generation RACE EVO and R-Motion Nickel-Titanium Instruments. MATERIALS 2022; 15:ma15093330. [PMID: 35591664 PMCID: PMC9105925 DOI: 10.3390/ma15093330] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/21/2022] [Accepted: 05/03/2022] [Indexed: 12/04/2022]
Abstract
This study aimed to evaluate and compare the dynamic cyclic fatigue, torsional and bending resistance of two novel RACE EVO (FKG Dentaire SA, La Chaux de Fonds, Switzerland) and R-Motion (FKG) nickel−titanium instruments with traditional RaCe (FKG) instruments. RACE EVO, R-Motion and RaCe instruments with a size of 25 and taper of 0.06 were used. A dynamic cyclic fatigue test was used to assess the time to fracture. The fractured surfaces were further analyzed using scanning electron microscopy at ×350 and ×3000 magnifications. A torsional resistance test was performed to measure the maximum torsional strength and angle of rotation. Phase transformations with temperature were evaluated using differential scanning calorimetry. The results were statistically analyzed with a Kruskal−Wallis test at a 5% significance level. R-Motion had the highest time to fracture and the lowest torsional and bending resistance, whereas RaCe had the lowest time to fracture and the highest torsional and bending resistance (p < 0.05). In relation to the angle of rotation, RACE EVO instruments had the highest deformation capacity followed by R-Motion and RaCe instruments (p < 0.05). The greater cyclic fatigue resistance and lower torsional and bending resistance results indicate that the novel R-Motion and RACE EVO instruments are less rigid and more flexible than RaCe instruments.
Collapse
Affiliation(s)
- Fatima Betul Basturk
- Department of Endodontics, Istanbul Gelişim University, Istanbul 34310, Turkey
- Correspondence:
| | - Taha Özyürek
- Department of Endodontics, Bahçeşehir University, Istanbul 34734, Turkey;
| | - Gülşah Uslu
- Department of Endodontics, Çanakkale Onsekiz Mart University, Çanakkale 17100, Turkey;
| | - Mustafa Gündoğar
- Department of Endodontics, Istanbul Medipol University, Istanbul 34083, Turkey;
| |
Collapse
|
21
|
Martins JNR, Marques D, Vasconcelos I, Arantes-Oliveira S, Caramês J, Braz Fernandes FM. Multimethod Assessment of the Cyclic Fatigue Strength of ProGlider, Edge Glide Path and R-Pilot Endodontic Instruments. Dent J (Basel) 2022; 10:dj10020030. [PMID: 35200255 PMCID: PMC8870709 DOI: 10.3390/dj10020030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Revised: 02/11/2022] [Accepted: 02/15/2022] [Indexed: 12/03/2022] Open
Abstract
Background: The aim of this study was to comprehensively evaluate the cyclic fatigue strength of ProGlider, Edge Glide Path, and R-Pilot instruments. Methods: Sixty-three instruments were submitted to a multimethod evaluation. Their design was analyzed by stereomicroscopy and scanning electron microscopy, including the number of blades, helical angle means, cross-sectional design, surface finishing, and symmetry. Energy-dispersive X-ray spectroscopy was used determine the nickel/titanium elements ratio, and differential scanning calorimetry determined the instruments’ phase transformation temperatures. The cyclic fatigue tests were conducted in an artificial canal with a 6 mm radius and 86 degrees of curvature. The Mood’s median test and one-way ANOVA were used to determine differences, with the significance level set at 0.05. Results: The ProGlider presented the highest number of blades (n = 21), while R-Pilot had the highest helical angles (26.4°). Differences were noted in the instruments’ cross-sections and surface finishing. The ProGlider and R-Pilot showed some similarities regarding the phase transformation temperatures but differed from the Edge Glide Path. All alloys showed an almost equiatomic nickel/titanium ratio. The R-Pilot instruments showed a significantly higher (p < 0.05) time to fracture than both the other files. Conclusion: Reciprocating R-Pilot instruments showed a higher cyclic fatigue time to fracture than the ProGlider and Edge Glide Path rotary files.
Collapse
Affiliation(s)
- Jorge N. R. Martins
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
- Implantology Institute, 1070-064 Liaboa, Portugal
- Correspondence:
| | - Duarte Marques
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Centro de Estudo de Medicina Dentária Baseada na Evidência (CEMDBE), 1600-277 Lisboa, Portugal
- Implantology Institute, 1070-064 Liaboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - Isabel Vasconcelos
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Center for Rapid and Sustainable Product Development, Polytechnic Institute of Leiria, 2411-901 Leiria, Portugal
| | - Sofia Arantes-Oliveira
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - João Caramês
- Faculdade de Medicina Dentária, Universidade de Lisboa, 1600-277 Lisboa, Portugal; (D.M.); (I.V.); (S.A.-O.); (J.C.)
- Implantology Institute, 1070-064 Liaboa, Portugal
- LIBPhys-FCT UID/FIS/04559/2013, 1600-277 Lisboa, Portugal
| | - Francisco Manuel Braz Fernandes
- CENIMAT/I3N, Department of Materials Science, NOVA School of Science and Technology, Universidade NOVA de Lisboa, 2829-516 Caparica, Portugal;
| |
Collapse
|
22
|
Sharma S, Savitha S, Kumar V, Chawla A, Vanamail P, Logani A. Effect of body temperature on the cyclic fatigue resistance of the nickel”titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies. J Conserv Dent 2022; 25:338-346. [PMID: 36187856 PMCID: PMC9520645 DOI: 10.4103/jcd.jcd_55_22] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 04/18/2022] [Accepted: 05/03/2022] [Indexed: 11/27/2022] Open
Abstract
Aim: The aim of this systematic review was to compare the effect of body temperature (I) on the cyclic fatigue resistance (O) of nickel–titanium (NiTi) endodontic instruments (P) to that of room temperature (C). Methods: The study was registered in the PROSPERO database (CRD42020204286). A systematic search in PubMed, Scopus, Web of Science, Google Scholar, and OpenGrey was conducted in English until December 31, 2021. In vitro studies comparing the cyclic fatigue resistance of NiTi instruments at the body (35°C ± 2°C) and room temperature (20°C–25°C) were included. Eligible studies were evaluated for risk of bias and meta-analyzed to estimate the effects. Results: Twenty-one studies out of 347 met the criteria for inclusion. The meta-analysis included six studies (n = 215) with comparative study parameters. The overall effect sizes (5.49; 95% confidence interval [CI]: 4.04–6.93) were significantly different (P < 0.001), indicating that the mean values at room temperature were significantly (P < 0.001) higher. The effect sizes for full rotary motion (standardized mean difference [SMD]: 4.80; 95% CI: 3.04–6.56) and reciprocating motion (SMD: 6.37; 95% CI: 3.63–9.11) were not significantly different (P = 0.346). Heterogeneity was high (I2 = 94%). Sensitivity analysis revealed that the SMD values were not significantly different (P > 0.05) from the overall effect size, indicating that none of the studies had an effect on the overall effect size. Conclusions: Within the limitation of the study, the cyclic fatigue resistance of heat-treated NiTi endodontic files is significantly reduced at body temperature when compared to room temperature. Cyclic fatigue testing should be conducted at simulated body temperature.
Collapse
|
23
|
MESQUITA ML, BUENO CEDS, DE MARTIN AS, PELEGRINE RA, FONTANA CE. Influência do hipoclorito de sódio na resistência à fadiga cíclica em instrumentos rotatórios endodônticos de memória controlada de NiTi: uma avaliação experimental. REVISTA DE ODONTOLOGIA DA UNESP 2022. [DOI: 10.1590/1807-2577.04622] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Resumo Introdução É importante saber se o hipoclorito de sódio (NaOCl) influencia a resistência à fadiga cíclica das limas de níquel-titânio (NiTi). Objetivo Avaliar a influência de NaOCl 2,5% na resistência à fadiga cíclica de dois sistemas de NiTi. Material e método: 40 instrumentos rotatórios – 20 TruNatomy® (TRU, Dentsply Sirona, Maillefer, Ballaigues, Suíça) e 20 Prodesing Logic2® (PDL2, Bassi, Belo Horizonte, Minas Gerais, Brasil) – foram aleatoriamente distribuídos em 4 grupos experimentais (n = 10) imersos em água destilada (H2O) e NaOCl 2,5% em temperatura a 37°C. Foram submetidos a testes de fadiga cíclica mensurando o número de ciclos para fratura (NCF) e análise dessas superfícies pós-teste em microscópio eletrônico por varredura. Para a análise estatística entre os grupos, foi aplicada a análise de variância (ANOVA), complementada com o pós-teste de Tukey. Resultado Houve diferença estatística em todos os grupos (P < 0,05). Os instrumentos PDL2 obtiveram maior resistência à fratura nas condições em H2O e em NaOCl 2,5% comparados aos instrumentos TRU. Na análise de grupos de instrumentos nas soluções de NaOCl e H2O, foi observado que o NaOCl 2,5% diminuiu o NCF. Conclusão A resistência à fadiga cíclica dos instrumentos TRU e PDL2 diminuiu com NaOCl 2,5%. Os instrumentos PDL2 foram mais resistentes à fratura em relação aos instrumentos TRU.
Collapse
|
24
|
Comparison of Cyclic Fatigue Resistance of Heat-Treated Nickel-Titanium Reciprocating Instruments at the Intracanal Temperature. BALKAN JOURNAL OF DENTAL MEDICINE 2021. [DOI: 10.2478/bjdm-2021-0014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Summary
Background/Aim: The aim of the present study was to compare the cyclic fatigue resistance of NiTi files running with reciprocal motion and having different characteristics (RPC Blue, WOG, EndoArt Wise Reciproc Gold, EndoArt Wise Reciproc Blue) at the intracanal temperature (35°C) by using NaOCl irrigation solution.
Material and Methods: Totally 60 WaveOne GOLD (Dentsply-Sirona, Ballaigues, Switzerland), Reciproc Blue (VDW, Munich, Germany), EndoArt Wise Reciproc Gold, and EndoArt Wise Blue (Inci Dental Productions Co, Istanbul, Turkey) (n= 15) files were used. Each of the rotary files were tested at the intracanal temperature (35°C) using a dynamic model in a stainless-steel artificial canal with an inner diameter of 1.5 mm, 60° angle of curvature, and 2mm radius of curvature until fracture occurred. The device automatically stopped at the moment of fracture and the number of cycles to the fracture was calculated as per second. The lengths of fractured parts were measured using a digital microcaliper. The One-Way Analysis of Variance (ANOVA) and Tukey’s post-hoc tests were used for intergroup comparisons.
Results: In 2 mm Radius of curvature, the EndoArt Wise Reciproc Blue group had a significantly higher time to fracture followed by the EndoArt Wise Reciproc Gold, Resiproc Blue, WaveOne Gold. No significant difference was found between EndoArt Wise Reciproc Gold and Resiproc Blue groups (P>0.05). Among the groups, there was no statistically significant difference in the lengths of fractured parts of the instruments (P> 0.05).
Conclusions: EndoArt Wise Reciproc Blue files exhibited significantly higher cyclic fatigue resistance compared with other files tested in a 2-mm radius of curvature and a 60° angle in an artificial canal at the intracanal temperature.
Collapse
|
25
|
Nino-Barrera J, Sanchez-Aleman J, Acosta-Humanez M, Gamboa-Martinez L, Cortes-Rodriguez C. Shot peening increases resistance to cyclic fatigue fracture of endodontic files. Sci Rep 2021; 11:12961. [PMID: 34155287 PMCID: PMC8217493 DOI: 10.1038/s41598-021-92382-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 06/09/2021] [Indexed: 11/09/2022] Open
Abstract
The objective of this study was to assess the resistance to fatigue fracture of conventional nickel–titanium files after undergoing shot peening. Forty NITIFLEX endodontic files, number 30, were divided into two groups; one was submitted to shot peening treatment and the other was not. All instruments were tested for fatigue fracture in simulated canals with a TRI-AUTO ZX endodontic motor. One file of each group was subjected to a residual stress analysis by XRD. Finally, the fractured surface was observed and elemental analysis performed by means of SEM and EDX. Roughness analysis was made by focal variation microscope. The shot peening group showed greater resistance to fatigue fracture; there was no difference in the length of the fractured fragments. XRD results showed the presence of residual compression stresses in the file submitted to shot peening, a decrease in the interplanar spacing, and an increase in the full-width-at-half-maximum and the microstrains. SEM and EDX showed a ductile fracture with zones of fatigue and an equiatomic ratio between the nickel and titanium. Surface roughness increased after the file was subjected to the shot peening procedure. In conclusion, shot peening increases the resistance to fatigue fracture due to the presence of residual compression stresses in files manufactured from a conventional nickel–titanium alloy.
Collapse
Affiliation(s)
- Javier Nino-Barrera
- Faculty of Dentistry, Endodontics Program, Universidad Nacional de Colombia, Building 210, Office 301, Bogotá, Colombia.
| | - Jose Sanchez-Aleman
- Faculty of Dentistry, Endodontics Program, Universidad Nacional de Colombia, Building 210, Office 301, Bogotá, Colombia
| | | | - Luis Gamboa-Martinez
- School of Dentistry, Endodontics Program, Universidad El Bosque, Bogotá, Colombia
| | | |
Collapse
|
26
|
Zubizarreta-Macho Á, Albaladejo Martínez A, Falcão Costa C, Quispe-López N, Agustín-Panadero R, Mena-Álvarez J. Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model. BMC Oral Health 2021; 21:179. [PMID: 33827530 PMCID: PMC8028824 DOI: 10.1186/s12903-021-01538-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 03/25/2021] [Indexed: 11/10/2022] Open
Abstract
Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files.
Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodontic files was registered. The results were analyzed by ANOVA and Weibull statistics. Results Statistically significant differences were found when the number of cycles of in-and-out movement and the time to failure of ReFlex Dynamic and Reciproc reciprocating movement (p < 0.001) and between ReFlex Smart and Reciproc reciprocating movement (p < 0.001) were compared in pairs. However, no statistically significant differences were observed between time to failure and number of cycles of in-and-out movement of ReFlex Dynamic and ReFlex Smart reciprocating movement (p = 0.253). Conclusions The ReFlex Smart reciprocating movement increased the cyclic fatigue resistance of endodontic reciprocating files compared with traditional reciprocating movement.
Collapse
Affiliation(s)
- Álvaro Zubizarreta-Macho
- Department of Endodontics, Faculty of Dentistry, Alfonso X el Sabio University, 28691, Madrid, Spain
| | | | - Carlos Falcão Costa
- Faculty of Health Sciences, Fernando Pessoa University, 4150-518, Porto, Portugal
| | - Norberto Quispe-López
- Department of Endodontics, Faculty of Dentistry, Alfonso X el Sabio University, 28691, Madrid, Spain
| | - Ruben Agustín-Panadero
- Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010, Valencia, Spain
| | - Jesús Mena-Álvarez
- Department of Endodontics, Faculty of Dentistry, Alfonso X el Sabio University, 28691, Madrid, Spain. .,Department of Endodontics, Faculty of Dentistry, Alfonso X El Sabio University, Albarracin 35, 28037, Madrid, Spain.
| |
Collapse
|
27
|
Abstract
OBJECTIVE The aim of this study was to evaluate the cyclic fatigue, torsional behavior and bending resistance of EdgeTaper Platinum [ETP (tip 25, taper 0.06)], Flex Gold [FG (tip 25, taper 0.08)], Pro-T [PT (tip 25, taper 0.08)] and ProTaper Gold [PTG (tip 25, taper 0.08)] systems. METHODS Rotary instruments of ETP, PT, FG, and PTG were used (n=30). Cyclic fatigue tests were performed using an artificial stainless-steel canal with a 60o angle and a 5-mm radius of curvature at body temperature (35°±1°C). The time and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). The bending test evaluated the torque required to bend the instruments at an angular deflection of 60°. Data were analyzed using one-way ANOVA and Tukey tests, and the level of significance was set at 5%. RESULTS The ETP had highest time until fracture and NCF than all the groups (P<0.05). The PTG had the highest torsional strength, followed by FG (P<0.05). The ETP had the highest angular rotation, followed by PT and PTG (P<0.05). The FG showed the highest bending resistance, followed by the PTG (P<0.05). CONCLUSION In conclusion, the ETP and PT exhibited higher cyclic fatigue resistance, higher angular deflection values and lower bending force than FG and PTG. The PTG instruments showed the highest torsional strength and the lowest cyclic fatigue resistance.
Collapse
|
28
|
Martins JN, Silva EJ, Marques D, Pereira MR, Ginjeira A, Silva RJ, Braz Fernandes FM, Versiani MA. Mechanical Performance and Metallurgical Features of ProTaper Universal and 6 Replicalike Systems. J Endod 2020; 46:1884-1893. [DOI: 10.1016/j.joen.2020.08.021] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 08/25/2020] [Accepted: 08/29/2020] [Indexed: 11/29/2022]
|
29
|
Seracchiani M, Miccoli G, Di Nardo D, Zanza A, Cantore M, Gambarini G, Testarelli L. Effect of Flexural Stress on Torsional Resistance of NiTi Instruments. J Endod 2020; 47:472-476. [PMID: 33096192 DOI: 10.1016/j.joen.2020.10.011] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 09/27/2020] [Accepted: 10/15/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION Previously published studies have deeply investigated the characteristics of flexural and torsional resistance of nickel-titanium rotary instruments, but none of them investigated the relationship between the 2 stresses. The objective of the present study was to evaluate the influence of flexural stresses over torsional resistance. METHODS Sixty S-One 20.04 files (Fanta Dental, Shanghai, China) were used in the present study (N = 60) and divided into 3 test groups of 20 files. A customized device made of a mobile structure with a connection that holds the handpiece and the artificial canal was used for the experiment to make the measurements repeatable. The artificial canals were created with a 90° curvature, a 60° curvature, and lastly a straight canal. Each file was rotated at 300 rpm with a maximum torque value of 5.5 Ncm with the apical 2 mm firmly secured in a vise. The torque at fracture and the time to fracture were recorded by the software integrated in the handpiece and evaluated through statistical analysis. RESULTS Statistical analysis found significant differences in the values of torque to fracture (TtF) between these 3 groups (P < .05). The 90° curved canal group showed the highest TtF value, and the 60° curved canal group showed a higher TtF value than the straight canal group. CONCLUSIONS The results of the present study demonstrated a positive influence of flexural stresses over torque at fracture of rotary files. When nickel-titanium instruments were used in a 90° or 60° curvature, the values of torque at fracture increased compared with the same instruments that rotated in the straight canal.
Collapse
Affiliation(s)
- Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Gabriele Miccoli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy.
| | - Alessio Zanza
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Marco Cantore
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
30
|
Uslu G, Gundogar M, Özyurek T, Plotino G. Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature. J Dent Res Dent Clin Dent Prospects 2020; 14:111-115. [PMID: 32908652 PMCID: PMC7464224 DOI: 10.34172/joddd.2020.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Accepted: 02/12/2020] [Indexed: 11/09/2022] Open
Abstract
Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical environment. Methods. Eighty NiTi files were used for the fatigue testing in stainless steel canals compatible with instrument sizes until fracture occurred (n=20): VDW.ROTATE (04./25#), TruNatomy Prime (04./26#), HyFlex CM (04./25#) and 2Shape TS04./25#( 1). For each instrument, the number of cycles to fracture (NCF) was calculated, and the fractured fragment length (FL) was measured. To verify that the files were fractured due to cyclic fatigue, the fractured surfaces of the files were evaluated under a scanning electron microscope. Data were statistically analyzed using the Kruskal-Wallis and Student's t-tests at the %95 confidence level. Results. The failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature (P<0.05). The highest fatigue resistance was observed in VDW.ROTATE and HyFlex CM files in both curvatures (P<0.05). There were no significant differences in the fatigue resistance between the HyFlex CM and VDW.ROTATE files or between the 2Shape and the TruNatomy files (P>0.05). There was no difference in the fractured lengths of the files between the apical and coronal curvatures (P>0.05). Conclusion. In artificial S-shaped root canals, VDW.ROTATE and HyFlex CM files exhibited higher fatigue resistance compared to 2Shape and TruNatomy files.
Collapse
Affiliation(s)
- Gülşah Uslu
- Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Mustafa Gundogar
- Department of Endodontics, Faculty of Dentistry, Istanbul Medipol University, İstanbul, Turkey
| | - Taha Özyurek
- Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | | |
Collapse
|
31
|
Gündoğar M, Uslu G, Özyürek T, Plotino G. Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature. Restor Dent Endod 2020; 45:e37. [PMID: 32839718 PMCID: PMC7431933 DOI: 10.5395/rde.2020.45.e37] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 03/23/2020] [Accepted: 03/23/2020] [Indexed: 11/11/2022] Open
Abstract
Objectives This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature. Materials and Methods In total, 80 VDW.ROTATE (25/0.04), TruNatomy (26/0.04), 2Shape (25/0.04), and HyFlex CM (25/0.04) NiTi rotary files (n = 20 in each group) were subjected to static cyclic fatigue testing at body temperature (37°C) in stainless-steel artificial canals prepared according to the size and taper of the instruments until fracture occurred. The number of cycles to fracture (NCF) was calculated, and the lengths of the fractured fragments were measured. The data were statistically analyzed using a 1-way analysis of variance and post hoc Tamhane tests at the 5% significance level (p < 0.05). Results There were significant differences in the cyclic fatigue resistance among the groups (p < 0.05), with the highest to lowest NCF values of the files as follows: VDW.ROTATE, HyFlex CM, 2Shape, and TruNatomy. There was no significant difference in the lengths of the fractured fragments among the groups. The scanning electron microscope images of the files revealed typical characteristics of fracture due to cyclic fatigue. Conclusions The VDW.ROTATE files had the highest cyclic fatigue resistance, and the TruNatomy and 2Shape files had the lowest cyclic fatigue resistance in artificial canals at body temperature.
Collapse
Affiliation(s)
- Mustafa Gündoğar
- Department of Endodontics, Faculty of Dentistry, İstanbul Medipol University, İstanbul, Turkey
| | - Gülşah Uslu
- Department of Endodontics, Faculty of Dentistry, Çanakkale Onsekiz Mart University, Çanakkale, Turkey
| | - Taha Özyürek
- Department of Endodontics, Faculty of Dentistry, Istanbul Medeniyet University, Istanbul, Turkey
| | | |
Collapse
|
32
|
Duque JA, Bramante CM, Duarte MAH, Alcalde MP, Silva EJNL, Vivan RR. Cyclic Fatigue Resistance of Nickel-Titanium Reciprocating Instruments after Simulated Clinical Use. J Endod 2020; 46:1771-1775. [PMID: 32818567 DOI: 10.1016/j.joen.2020.08.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 07/23/2020] [Accepted: 08/10/2020] [Indexed: 12/11/2022]
Abstract
INTRODUCTION The aim of this study was to evaluate the cyclic fatigue resistance of different heat-treated nickel-titanium reciprocating instruments in 2 different situations: new and used instruments after preparing 3 curved canals. METHODS A total sample of 60 nickel-titanium instruments of 3 systems (n = 20 per system) were used in this study: ProDesign R (tip 25, 0.06 taper; Easy Dental Equipment, Belo Horizonte, Brazil), Reciproc Blue (tip 25, 0.08v taper; VDW, Munich, Germany), and WaveOne Gold (tip 25, 0.07v taper; Dentsply Sirona, Ballaigues, Switzerland). Thirty new instruments (n = 10 per system) were used to prepare 90 curved single-rooted mandibular premolars (n = 30). Each instrument was used to prepare 3 root canals, and after each canal preparation the instrument was ultrasonic cleaned and submitted to autoclave sterilization procedures. The other 30 instruments (n = 10 per system) were kept without use. Then, the new and used instruments were subjected to the cyclic fatigue test in an artificial canal with a 30° angle and a 5-mm radius of curvature. The time and number of cycles to fatigue were recorded. Data were analyzed using the unpaired t test for intragroup comparison. For intergroup comparison, analysis of variance and the Tukey test for multiple comparisons were used. RESULTS The intergroup comparison of new instruments showed that ProDesign R had the highest cyclic fatigue resistance followed by Reciproc Blue and WaveOne Gold (P < .05). Regarding the used instruments, WaveOne Gold had the lowest cyclic fatigue resistance (P < .05). The intragroup comparison between new and used instruments showed that WaveOne Gold and ProDesign R presented a significant reduction in the cyclic fatigue resistance after simulated clinical use (P < .05); no difference was found with the Reciproc Blue instruments (P > .05). CONCLUSIONS ProDesign R had the highest cyclic fatigue resistance, whereas WaveOne Gold had the lowest for new and used instruments. Simulated clinical use affected the cyclic fatigue resistance of ProDesign R and WaveOne Gold but not of Reciproc Blue instruments.
Collapse
Affiliation(s)
- Jussaro Alves Duque
- Department of Endodontics, Ourinhos Integrated School, Ourinhos, São Paulo, Brazil; Department of Dentistry, Endodontics, and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, São Paulo, Brazil.
| | - Clovis Monteiro Bramante
- Department of Dentistry, Endodontics, and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, São Paulo, Brazil
| | - Marco Antonio Hungaro Duarte
- Department of Dentistry, Endodontics, and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, São Paulo, Brazil
| | - Murilo Priori Alcalde
- Department of Dentistry, Endodontics, and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, São Paulo, Brazil
| | | | - Rodrigo Ricci Vivan
- Department of Dentistry, Endodontics, and Dental Materials, School of Dentistry of Bauru, University of São Paulo, São Paulo, São Paulo, Brazil
| |
Collapse
|
33
|
Thu M, Ebihara A, Maki K, Miki N, Okiji T. Cyclic Fatigue Resistance of Rotary and Reciprocating Nickel-Titanium Instruments Subjected to Static and Dynamic Tests. J Endod 2020; 46:1752-1757. [PMID: 32818563 DOI: 10.1016/j.joen.2020.08.006] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Revised: 07/28/2020] [Accepted: 08/10/2020] [Indexed: 11/18/2022]
Abstract
INTRODUCTION This study compared the static and dynamic cyclic fatigue resistance of contemporary nickel-titanium instruments with different kinematic, metallurgic, and design features to establish whether the fatigue-reducing effect of the pecking motion differs among different nickel-titanium instruments. METHODS ProTaper Gold (PTG), Hyflex EDM (EDM), Reciproc Blue (RPB), and WaveOne Gold (WOG) files were divided into 2 groups of 10 for the static and dynamic cyclic fatigue resistance tests. A stainless steel artificial canal with 1.5-mm inner diameter, 60° angulation, and 3-mm radius of curvature was used. In the dynamic cyclic fatigue resistance test, speeds were set at 100 and 200 mm/min for the descending and ascending motion, respectively. The number of cycles to fracture (NCF) was calculated, the fractured lengths were recorded, and fractographic analysis of the fractured surfaces was carried out by scanning electron microscopy. Data were analyzed statistically with the Kruskal-Wallis test with Bonferroni correction (alpha = 0.05). RESULTS The RPB and EDM showed significantly higher NCF in the static and dynamic cyclic fatigue resistance tests (P < .05). The dynamic cyclic fatigue resistance test showed significantly higher NCF than the static cyclic fatigue resistance test in the PTG and EDM (P < .05). There was no significant difference between the RPB and WOG (P > .05). CONCLUSIONS In the experimental condition where the ascending speed was higher than the descending speed, the dynamic cyclic fatigue resistance was significantly higher than the static cyclic fatigue resistance in continuous rotary instruments, but not in reciprocating instruments.
Collapse
Affiliation(s)
- Myint Thu
- Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TDMU), Tokyo, Japan
| | - Arata Ebihara
- Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TDMU), Tokyo, Japan.
| | - Keiichiro Maki
- Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TDMU), Tokyo, Japan
| | - Nishijo Miki
- Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TDMU), Tokyo, Japan
| | - Takashi Okiji
- Division of Oral Health Sciences, Department of Pulp Biology and Endodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TDMU), Tokyo, Japan
| |
Collapse
|
34
|
Lopes WSP, Vieira VTL, Silva EJNL, Silva MCD, Alves FRF, Lopes HP, Pires FR. Bending, buckling and torsional resistance of rotary and reciprocating glide path instruments. Int Endod J 2020; 53:1689-1695. [PMID: 32767775 DOI: 10.1111/iej.13385] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 07/31/2020] [Accepted: 08/04/2020] [Indexed: 11/27/2022]
Abstract
AIM To evaluate the bending, buckling and torsional resistance of ProGlider (PG) (Dentsply Sirona, Ballaigues, Switzerland), R-Pilot (RP) (VDW, Munich, Germany) and WaveOne Gold Glider (WOGG) (Dentsply Sirona). METHODOLOGY Ninety instruments were used: 30 PG (size 0.16, .02v taper), 30 RP (size 0.125, .04 taper) and 30 WOGG (size 0.15, .02v taper). The bending resistance test was performed on 10 randomly selected instruments of each system according to ISO 3630-1 specifications. For the buckling resistance test, a loading was applied in the axial direction of each instrument using a universal test machine, with a 20 N cell and 15 mm min-1 speed, in the axial direction. When a lateral elastic displacement of 1 mm occurred, the force was registered. The torsional resistance test was performed according to ISO 3630-1 specifications. Statistical analysis was performed using one-way anova and post hoc Student-Newman-Keuls test (P < 0.05). RESULTS WOGG had the lowest bending resistance, whilst RP had the highest bending resistance (P < 0.05). RP also had the highest buckling resistance, and WOGG had the lowest (P < 0.05). PG had intermediate results regarding bending and buckling resistance, with significant differences to RP and WOGG (P < 0.05). RP had the highest torsional strength and the lowest angular deflection when compared to PG and WOGG (P < 0.05). No differences in the torsional strength and angular deflection were observed between WOGG and PG (P> 0.05). CONCLUSION The glide path instruments had different behaviours in term of bending, buckling and torsional resistance.
Collapse
Affiliation(s)
- W S P Lopes
- Department of Endodontics, School of Dentistry, UNESA - Estácio de Sá University, Rio de Janeiro, Brazil
| | - V T L Vieira
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - E J N L Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - M C D Silva
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - F R F Alves
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - H P Lopes
- Department of Endodontics, Grande Rio University (UNIGRANRIO), Rio de Janeiro, Brazil
| | - F R Pires
- Department of Endodontics, School of Dentistry, UNESA - Estácio de Sá University, Rio de Janeiro, Brazil
| |
Collapse
|
35
|
Martins JN, Nogueira Leal Silva EJ, Marques D, Ginjeira A, Braz Fernandes FM, De Deus G, Versiani MA. Influence of Kinematics on the Cyclic Fatigue Resistance of Replicalike and Original Brand Rotary Instruments. J Endod 2020; 46:1136-1143. [DOI: 10.1016/j.joen.2020.05.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/16/2020] [Accepted: 05/01/2020] [Indexed: 10/24/2022]
|
36
|
Novel Electronic Device to Quantify the Cyclic Fatigue Resistance of Endodontic Reciprocating Files after Using and Sterilization. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10144962] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background: The aim of this study was to analyze the effects of the time of use (TU) and sterilization cycles (SC) of endodontic reciprocating files on cyclic fatigue resistance. Methods: One-hundred-and-twenty (120) Procodile NiTi endodontic reciprocating instruments were selected at random and distributed into the following study groups: A: 0 sterilization cycles/0s time of use (n = 10); B: 0/60 (n = 10); C: 0/120 (n = 10); D: 1/0 (n = 10); E: 1/60 (n = 10); F: 1/120 (n = 10); G: 5/0 (n = 10); H: 5/60 (n = 10); I: 5/120 (n = 10); J: 10/0 (n = 10); K: 10/60 (n = 10); and L: 10/120 (n = 10). A dynamic cyclic fatigue device was designed using computer-aided design/computer-aided engineering (CAD/CAE) technology and created with a 3D printer to simulate the pecking motion performed by the clinician. Failure of the endodontic rotary instrument was detected by a light-emitting diode-light-dependent resistor (LED-LDR) system controlled by an Arduino driver complex and management software. The results were analyzed using the ANOVA test. Results: All pairwise comparisons presented statistically significant differences between the time to failure, number of cycles to failure and number of cycles of in-and-out movement for the time of use study groups (p < 0.001), but not in the number of sterilization cycles (p > 0.05). Conclusions: The time of use of NiTi endodontic reciprocating files negatively affects dynamic cyclic fatigue resistance. Dynamic cyclic resistance is not affected by the number of sterilization cycles.
Collapse
|
37
|
Micoogullari Kurt S, Kaval ME, Serefoglu B, Kandemir Demirci G, Çalışkan MK. Cyclic fatigue resistance and energy dispersive X-ray spectroscopy analysis of novel heat-treated nickel-titanium instruments at body temperature. Microsc Res Tech 2020; 83:790-794. [PMID: 32170795 DOI: 10.1002/jemt.23469] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2019] [Revised: 01/25/2020] [Accepted: 02/22/2020] [Indexed: 11/12/2022]
Abstract
The aim of this study was to evaluate the cyclic fatigue resistance of Dia-X, WaveOne Gold and One Curve files in a water bath at intracanal temperature (35°C). Thirty-nine instruments Dia-X, WaveOne Gold, and One Curve systems (n = 13) were tested in an artificial canal with a curvature angle of 60° and a radius of 3 mm. A water bath setup at a temperature of 35°C was used to simulate the intracanal temperature and time to fracture (TTF) as seconds was recorded. The mean data were analyzed statistically using one-way ANOVA, and post hoc Tukey test (p = .05). The fractured surface of the instruments was examined with scanning electron microscopy (SEM) and chemical composition of the instruments were investigated with energy dispersive X-ray spectroscopy (EDS). Statistically significant differences were detected in TTF values of all the systems as follows: One Curve > WaveOne Gold > Dia-X (p < .05). One Curve instruments demonstrated the highest TTF values in all the tested instruments. The EDS microanalysis revealed similar NiTi composition of on the surface of One Curve, WaveOne Gold, and Dia-X instruments. The novel manufacturing process, including C-wire heat treatment and the variable cross-section of the One Curve files, could be the main factors affecting the fatigue life of the instruments.
Collapse
Affiliation(s)
| | - Mehmet Emin Kaval
- Department of Endodontology, Faculty of Dentistry, Ege University, İzmir, Turkey
| | - Burcu Serefoglu
- Department of Endodontology, Faculty of Dentistry, Ege University, İzmir, Turkey
| | | | | |
Collapse
|
38
|
Elnaghy AM, Elsaka SE, Elshazli AH. Dynamic cyclic and torsional fatigue resistance of TruNatomy compared with different nickel-titanium rotary instruments. AUST ENDOD J 2020; 46:226-233. [PMID: 32022376 DOI: 10.1111/aej.12396] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/15/2020] [Indexed: 12/11/2022]
Abstract
This study evaluated the dynamic cyclic and torsional fatigue resistance of recently introduced TruNatomy instruments (TRN) and compare with HyFlex CM (HFC), Vortex Blue (VB) and FlexMaster (FM) instruments. Size 20, 0.04 taper of TRN, HFC, VB and FM instruments was tested for dynamic cyclic and torsional fatigue resistance. Dynamic cyclic fatigue resistance was evaluated using an artificial canal with a radius of 5 mm and a 90° angle of curvature. The number of cycles to failure (NCF) was calculated. The dynamic torsional fatigue resistance was evaluated by holding a 5 mm of the tip of each instrument in a metal block with composite resin. Torsional fatigue resistance was recorded by counting the number of load applications before fracture for each instrument. The HFC instruments had greater fatigue resistance than VB, TRN and FM. FM had a higher resistance to torsional stress than TRN, HFC and VB instruments.
Collapse
Affiliation(s)
- Amr M Elnaghy
- Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| | - Shaymaa E Elsaka
- Department of Dental Biomaterials, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.,Department of Restorative Science, Alfarabi Private College for Dentistry and Nursing, Jeddah, Saudi Arabia
| | - Alaa H Elshazli
- Department of Endodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt
| |
Collapse
|
39
|
Serefoglu B, Miçooğulları Kurt S, Kaval ME, Güneri P, Kandemir Demirci G, Çalışkan MK. Cyclic Fatigue Resistance of Multiused Reciproc Blue Instruments during Retreatment Procedure. J Endod 2019; 46:277-282. [PMID: 31812359 DOI: 10.1016/j.joen.2019.10.024] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/18/2019] [Accepted: 10/25/2019] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Root canal retreatment procedure may reduce the mechanical resistance of nickel-titanium instruments and increase the frequency of instrument fracture. The aim of the present study was to evaluate the effect of multiuse of Reciproc Blue R25 instruments on cyclic fatigue resistance during retreatment procedure in mandibular molar teeth. METHODS Forty-eight Reciproc Blue R25 files were included in the study. In control group, 12 new Reciproc Blue R25 instruments were subjected to cyclic fatigue test by using a stainless steel artificial canal with a 90° angle and 3-mm radius of curvatures. In experimental groups, Reciproc Blue R25 files (n = 12) were used to remove the root canal filling (RCF) material of 1, 2, and 3 molar teeth, respectively. Then cyclic fatigue tests of these 36 instruments were performed. The number of cycles to fracture (NCF) and the length of the fractured fragment were calculated for each instrument. Working time for retreatment procedures was determined in seconds with a digital chronometer. The data were analyzed by using one-way analysis of variance followed by post hoc Tukey test and mixed-effect analysis (P = .05). RESULTS No significant difference was found between NCF values of new and first time used files (P > .05), but NCF values of new and first time used files were significantly higher than those of second and third time used files (P < .05). The second and third time used files revealed no difference (P > .05). As the number of uses increased, the average time for retreatment procedure statistically extended (P < .05). CONCLUSIONS Reciproc Blue R25 instrument can be used to remove RCF material of 2 molar teeth. However, because of its decreased NCF values, multiple use over 2 molars may not be suggested.
Collapse
Affiliation(s)
- Burcu Serefoglu
- Department of Endodontics, School of Dentistry, Ege University, Bornova, İzmir, Turkey.
| | | | - Mehmet Emin Kaval
- Department of Endodontics, School of Dentistry, Ege University, Bornova, İzmir, Turkey
| | - Pelin Güneri
- Department of Oral and Maxillofacial Radiology, School of Dentistry, Ege University, Bornova, Izmir, Turkey
| | | | - Mehmet Kemal Çalışkan
- Department of Endodontics, School of Dentistry, Ege University, Bornova, İzmir, Turkey
| |
Collapse
|
40
|
Scott R, Arias A, Macorra JC, Govindjee S, Peters OA. Resistance to cyclic fatigue of reciprocating instruments determined at body temperature and phase transformation analysis. AUST ENDOD J 2019; 45:400-406. [DOI: 10.1111/aej.12374] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/05/2019] [Indexed: 10/25/2022]
Affiliation(s)
- Raymond Scott
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
| | - Ana Arias
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
- Department of Conservative Dentistry and Prothesis School of Dentistry Complutense University Madrid Spain
| | - José C. Macorra
- Department of Conservative Dentistry and Prothesis School of Dentistry Complutense University Madrid Spain
| | - Sanjay Govindjee
- Department of Civil and Environmental Engineering University of California Berkeley California USA
| | - Ove A. Peters
- Department of Endodontics University of the Pacific Arthur A. Dugoni School of Dentistry San Francisco California USA
- Oral Health Centre University of Queensland Herston Queensland Australia
| |
Collapse
|
41
|
Gambarini G, Galli M, Di Nardo D, Seracchiani M, Donfrancesco O, Testarelli L. Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire. J Clin Exp Dent 2019; 11:e609-e613. [PMID: 31516658 PMCID: PMC6731004 DOI: 10.4317/jced.55839] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Accepted: 06/12/2019] [Indexed: 11/10/2022] Open
Abstract
Background Aim of this study is to investigate the cyclic fatigue resistance of the Gold treated WaveOne Gold and the Firewire treated EdgeOne Fire instruments. The null hypotesis was that there were no differences between the lifespan of Gold treated and FireWire treated instruments when subjected to cyclic fatigue tests. Material and Methods 40 new NiTi instruments with a length of 25 mm were tested: 20 Wave One Gold Medium (WOG), tip size 35 and variable taper (Dentsply Maillefer, Ballaigues, Switzerland) and 20 Edge One Fire (EOF) (EdgeEndo, Albuquerque, New Mexico) tip size 35 and the same variable taper. A mobile support for the electric handpiece and a stainless-steel block containing the artificial canals were used. The same artificial root canal with a 90 degrees angle of curvature and 2 mm radius of curvature was used for all the tested instruments and the WOG counter-clock wise reciprocating motion with an engaging angle of 150° and a disengaging angle of 30° at 300 rpm, was selected for the test. All instruments were inserted at the same length (18mm) and then rotated in the same reciprocating motion until fracture occurred: the time was stopped as soon as the fracture was visible and video-recorded with a 1/100 sec chronometer. Differences among groups were statistically evaluated with an analysis of variance test ANOVA (significance level was set at p<0.05). Results Mean values of time to fracture (TtF) for EOF instruments were 28,00 seconds (SD +/- 2,64) and for WOG instruments were 14,67 seconds (SD +/- 2,41). Statistical analysis found significant differences between the TtF of the two instruments (p<0,05). Conclusions Firewire instruments resulted to be about two times more resistant to cyclic fatigue when compared with identical instruments made with Gold treatment. Key words:Endodontics, NiTi, Waveone Gold, EdgeOne Fire, Cyclic Fatigue.
Collapse
Affiliation(s)
- Gianluca Gambarini
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| | - Massimo Galli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| | - Dario Di Nardo
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| | - Marco Seracchiani
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| | - Orlando Donfrancesco
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| | - Luca Testarelli
- Department of Oral and Maxillo-Facial Sciences, Sapienza University of Rome, Italy
| |
Collapse
|
42
|
Silva EJNL, Giraldes JFN, de Lima CO, Vieira VTL, Elias CN, Antunes HS. Influence of heat treatment on torsional resistance and surface roughness of nickel‐titanium instruments. Int Endod J 2019; 52:1645-1651. [DOI: 10.1111/iej.13164] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2018] [Accepted: 05/22/2019] [Indexed: 12/16/2022]
Affiliation(s)
- E. J. N. L. Silva
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO)Rio de Janeiro RJBrazil
| | - J. F. N. Giraldes
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO)Rio de Janeiro RJBrazil
| | - C. O. de Lima
- Department of Endodontics School of Dentistry State University of Rio de Janeiro (UERJ)Rio de Janeiro RJBrazil
| | - V. T. L. Vieira
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO)Rio de Janeiro RJBrazil
| | - C. N. Elias
- Materials Science Department Instituto Militar de Engenharia Rio de Janeiro RJ Brazil
| | - H. S. Antunes
- Department of Endodontics School of Dentistry Grande Rio University (UNIGRANRIO)Rio de Janeiro RJBrazil
| |
Collapse
|