1
|
Gill RL, Fleck R, Chau K, Westerhausen MT, Lockwood TE, Violi JP, Irga PJ, Doblin MA, Torpy FR. Fine particle pollution during megafires contains potentially toxic elements. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2024; 344:123306. [PMID: 38185362 DOI: 10.1016/j.envpol.2024.123306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 01/04/2024] [Accepted: 01/04/2024] [Indexed: 01/09/2024]
Abstract
Wildfires that raged across Australia during the 2019-2020 'Black Summer' produced an enormous quantity of particulate matter (PM) pollution, with plumes that cloaked many urban centres and ecosystems along the eastern seaboard. This has motivated a need to understand the magnitude and nature of PM exposure, so that its impact on both built and natural environments can be more accurately assessed. Here we present the potentially toxic fingerprint of PM captured by building heating, ventilation, and air conditioning filters in Sydney, Australia during the peak of the Wildfires, and from ambient urban emissions one year later (Reference period). Atmospheric PM and meteorological monitoring data were also assessed to determine the magnitude and source of high PM exposure. The wildfires were a major source of PM pollution in Sydney, exceeding the national standards on 19 % of days between November-February. Wildfire particles were finer and more spherical compared to Reference PM, with count median diameters of 892.1 ± 23.1 versus 1484.8 ± 96.7 nm (mean ± standard error). On an equal-mass basis, differences in potentially toxic elements were predominantly due to higher SO42--S (median 20.4 vs 4.7 mg g-1) and NO3--N (2.4 vs 1.2 mg g-1) in Wildfire PM, and higher PO43--P (10.4 vs 1.4 mg g-1) in Reference PM. Concentrations of remaining elements were similar or lower than Reference PM, except for enrichments to F-, Cl-, dissolved Mn, and particulate Mn, Co and Sb. Fractional solubilities of trace elements were similar or lower than Reference PM, except for enhanced Hg (12.1 vs 1.0 %) and greater variability in Cd, Hg and Mn solubility, which displayed upper quartiles exceeding that of Reference PM. These findings contribute to our understanding of human and ecosystem exposures to the toxic components of mixed smoke plumes, especially in regions downwind of the source.
Collapse
Affiliation(s)
- Raissa L Gill
- Productive Coasts, Climate Change Cluster, University of Technology Sydney, Ultimo, NSW, 2007, Australia; Plants and Environmental Quality Research Group, School of Life Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia.
| | - Robert Fleck
- Plants and Environmental Quality Research Group, School of Life Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Ky Chau
- Plants and Environmental Quality Research Group, School of Life Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Mika T Westerhausen
- Hyphenated Mass Spectrometry Laboratory, School of Mathematical and Physical Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Thomas E Lockwood
- Hyphenated Mass Spectrometry Laboratory, School of Mathematical and Physical Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Jake P Violi
- School of Chemistry, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Peter J Irga
- Plants and Environmental Quality Research Group, School of Civil and Environmental Engineering, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| | - Martina A Doblin
- Productive Coasts, Climate Change Cluster, University of Technology Sydney, Ultimo, NSW, 2007, Australia; Sydney Institute of Marine Science, Mosman, NSW, 2088, Australia
| | - Fraser R Torpy
- Plants and Environmental Quality Research Group, School of Life Sciences, University of Technology Sydney, Ultimo, NSW, 2007, Australia
| |
Collapse
|
2
|
Ouyang H, Wang L, Sapkota D, Yang M, Morán J, Li L, Olson BA, Schwartz M, Hogan CJ, Torremorell M. Control technologies to prevent aerosol-based disease transmission in animal agriculture production settings: a review of established and emerging approaches. Front Vet Sci 2023; 10:1291312. [PMID: 38033641 PMCID: PMC10682736 DOI: 10.3389/fvets.2023.1291312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 10/26/2023] [Indexed: 12/02/2023] Open
Abstract
Transmission of infectious agents via aerosols is an ever-present concern in animal agriculture production settings, as the aerosol route to disease transmission can lead to difficult-to-control and costly diseases, such as porcine respiratory and reproductive syndrome virus and influenza A virus. It is increasingly necessary to implement control technologies to mitigate aerosol-based disease transmission. Here, we review currently utilized and prospective future aerosol control technologies to collect and potentially inactivate pathogens in aerosols, with an emphasis on technologies that can be incorporated into mechanically driven (forced air) ventilation systems to prevent aerosol-based disease spread from facility to facility. Broadly, we find that control technologies can be grouped into three categories: (1) currently implemented technologies; (2) scaled technologies used in industrial and medical settings; and (3) emerging technologies. Category (1) solely consists of fibrous filter media, which have been demonstrated to reduce the spread of PRRSV between swine production facilities. We review the mechanisms by which filters function and are rated (minimum efficiency reporting values). Category (2) consists of electrostatic precipitators (ESPs), used industrially to collect aerosol particles in higher flow rate systems, and ultraviolet C (UV-C) systems, used in medical settings to inactivate pathogens. Finally, category (3) consists of a variety of technologies, including ionization-based systems, microwaves, and those generating reactive oxygen species, often with the goal of pathogen inactivation in aerosols. As such technologies are typically first tested through varied means at the laboratory scale, we additionally review control technology testing techniques at various stages of development, from laboratory studies to field demonstration, and in doing so, suggest uniform testing and report standards are needed. Testing standards should consider the cost-benefit of implementing the technologies applicable to the livestock species of interest. Finally, we examine economic models for implementing aerosol control technologies, defining the collected infectious particles per unit energy demand.
Collapse
Affiliation(s)
- Hui Ouyang
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States
- Department of Mechanical Engineering, University of Texas-Dallas, Richardson, TX, United States
| | - Lan Wang
- Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN, United States
| | - Deepak Sapkota
- Department of Mechanical Engineering, University of Texas-Dallas, Richardson, TX, United States
| | - My Yang
- Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN, United States
| | - José Morán
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Li Li
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Bernard A. Olson
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Mark Schwartz
- Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN, United States
- Schwartz Farms, Sleepy Eye, MN, United States
| | - Christopher J. Hogan
- Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN, United States
| | - Montserrat Torremorell
- Department of Veterinary Population Medicine, University of Minnesota, Saint Paul, MN, United States
| |
Collapse
|
3
|
Solar energy optimization in solar-HVAC using Sutterby hybrid nanofluid with Smoluchowski temperature conditions: a solar thermal application. Sci Rep 2022; 12:11484. [PMID: 35798787 PMCID: PMC9262953 DOI: 10.1038/s41598-022-15685-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 06/28/2022] [Indexed: 11/18/2022] Open
Abstract
In solar heating, ventilation, and air conditioning (HVAC), communications are designed to create new 3D mathematical models that address the flow of rotating Sutterby hybrid nanofluids exposed to slippery and expandable seats. The heat transmission investigation included effects such as copper and graphene oxide nanoparticles, as well as thermal radiative fluxing. The activation energy effect was used to investigate mass transfer with fluid concentration. The boundary constraints utilized were Maxwell speed and Smoluchowksi temperature slippage. With the utilization of fitting changes, partial differential equations (PDEs) for impetus, energy, and concentricity can be decreased to ordinary differential equations (ODEs). To address dimensionless ODEs, MATLAB’s Keller box numerical technique was employed. Graphene oxide Copper/engine oil (GO-Cu/EO) is taken into consideration to address the performance analysis of the current study. Physical attributes, for example, surface drag coefficient, heat move, and mass exchange are mathematically processed and shown as tables and figures when numerous diverse factors are varied. The temperature field is enhanced by an increase in the volume fraction of copper and graphene oxide nanoparticles, while the mass fraction field is enhanced by an increase in activation energy.
Collapse
|
4
|
Qiao Y, Yang M, Marabella IA, McGee DA, Olson BA, Torremorell M, Hogan CJ. Wind tunnel-based testing of a photoelectrochemical oxidative filter-based air purification unit in coronavirus and influenza aerosol removal and inactivation. INDOOR AIR 2021; 31:2058-2069. [PMID: 33960547 PMCID: PMC8242653 DOI: 10.1111/ina.12847] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Revised: 03/17/2021] [Accepted: 04/12/2021] [Indexed: 05/27/2023]
Abstract
Recirculating air purification technologies are employed as potential means of reducing exposure to aerosol particles and airborne viruses. Toward improved testing of recirculating air purification units, we developed and applied a medium-scale single-pass wind tunnel test to examine the size-dependent collection of particles and the collection and inactivation of viable bovine coronavirus (BCoV, a betacoronavirus), porcine respiratory coronavirus (PRCV, an alphacoronavirus), and influenza A virus (IAV), by a commercial air purification unit. The tested unit, the Molekule Air Mini, incorporates a MERV 16 filter as well as a photoelectrochemical oxidating layer. It was found to have a collection efficiency above 95.8% for all tested particle diameters and flow rates, with collection efficiencies above 99% for supermicrometer particles with the minimum collection efficiency for particles smaller than 100 nm. For all three tested viruses, the physical tracer-based log reduction was near 2.0 (99% removal). Conversely, the viable virus log reductions were found to be near 4.0 for IAV, 3.0 for BCoV, and 2.5 for PRCV, suggesting additional inactivation in a virus family- and genus-specific manner. In total, this work describes a suite of test methods which can be used to rigorously evaluate the efficacy of recirculating air purification technologies.
Collapse
Affiliation(s)
- Yuechen Qiao
- Department of Mechanical EngineeringCollege of Science and EngineeringUniversity of MinnesotaMinneapolisMNUSA
| | - My Yang
- Department of Veterinary Population MedicineCollege of Veterinary MedicineUniversity of MinnesotaSaint PaulMNUSA
| | - Ian A. Marabella
- Department of Mechanical EngineeringCollege of Science and EngineeringUniversity of MinnesotaMinneapolisMNUSA
| | - Devin A.J. McGee
- Department of Mechanical EngineeringCollege of Science and EngineeringUniversity of MinnesotaMinneapolisMNUSA
| | - Bernard A. Olson
- Department of Mechanical EngineeringCollege of Science and EngineeringUniversity of MinnesotaMinneapolisMNUSA
| | - Montserrat Torremorell
- Department of Veterinary Population MedicineCollege of Veterinary MedicineUniversity of MinnesotaSaint PaulMNUSA
| | - Christopher J. Hogan
- Department of Mechanical EngineeringCollege of Science and EngineeringUniversity of MinnesotaMinneapolisMNUSA
| |
Collapse
|
5
|
Mahdavi A, Dingle J, Chan AWH, Siegel JA. HVAC filtration of particles and trace metals: Airborne measurements and the evaluation of quantitative filter forensics. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2021; 271:116388. [PMID: 33388682 DOI: 10.1016/j.envpol.2020.116388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 12/12/2020] [Accepted: 12/23/2020] [Indexed: 06/12/2023]
Abstract
Filters installed in the heating, ventilation, and air-conditioning (HVAC) systems can serve as air-cleaning and sampling devices for indoor particles. The purpose of this article is to evaluate these dual roles. An occupied home with a central HVAC system equipped with a Minimum Efficiency Reporting Value (MERV, from ASHRAE Standard 52.2) 11 filter was monitored for six weeks. Weekly airborne gravimetric and real-time sampling was performed to measure the particle size distribution and the concentration of total suspended particles (TSP), PM10, PM2.5, PM1, and 12 trace metals. The weekly system runtimes were intentionally changed to provide a wide range of weekly filtration volumes. The quantitative filter forensics (QFF) concentrations of particulate matter (PM) and trace metals were calculated using the analysis of the dust collected on the HVAC filter, the filtration volume, and filter in-situ efficiency. The results indicated that filtration was not influential to remove PM and trace metals as the concentrations during the weeks with continuous HVAC operation were not consistently lower than those during the other weeks. This suggests the dominance of other particle and trace metal source and loss mechanisms weakens the influence of filtration in this home. The QFF evaluation results indicated that the concentration of TSP and over half of the tested trace metals (e.g., Pb, Cd, Ni, V, Sb, K, and Sr) could be estimated by QFF within a factor of two when compared to airborne sampling results. PM10, PM2.5, and PM1 concentrations were significantly underestimated by QFF potentially due to the limitations of size distribution analysis by a laser diffraction particle sizer (LDPS) for the detection of <1 μm particles. Overall, while QFF was promising for TSP and some trace metals, improvement in size distribution analysis could extend the application of QFF for airborne sampling.
Collapse
Affiliation(s)
- Alireza Mahdavi
- Department of Civil and Mineral Engineering, University of Toronto, Toronto, Canada
| | - Justin Dingle
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada
| | - Arthur W H Chan
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada
| | - Jeffrey A Siegel
- Department of Civil and Mineral Engineering, University of Toronto, Toronto, Canada; Dalla Lana School of Public Health, University of Toronto, Toronto, Canada.
| |
Collapse
|
6
|
Rajagopalan S, Brauer M, Bhatnagar A, Bhatt DL, Brook JR, Huang W, Münzel T, Newby D, Siegel J, Brook RD. Personal-Level Protective Actions Against Particulate Matter Air Pollution Exposure: A Scientific Statement From the American Heart Association. Circulation 2020; 142:e411-e431. [PMID: 33150789 DOI: 10.1161/cir.0000000000000931] [Citation(s) in RCA: 113] [Impact Index Per Article: 28.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Since the publication of the last American Heart Association scientific statement on air pollution and cardiovascular disease in 2010, unequivocal evidence of the causal role of fine particulate matter air pollution (PM2.5, or particulate matter ≤2.5 μm in diameter) in cardiovascular disease has emerged. There is a compelling case to provide the public with practical personalized approaches to reduce the health effects of PM2.5. Such interventions would be applicable not only to individuals in heavily polluted countries, high-risk or susceptible individuals living in cleaner environments, and microenvironments with higher pollution exposures, but also to those traveling to locations with high levels of PM2.5. The overarching motivation for this document is to summarize the current evidence supporting personal-level strategies to prevent the adverse cardiovascular effects of PM2.5, guide the use of the most proven/viable approaches, obviate the use of ineffective measures, and avoid unwarranted interventions. The significance of this statement relates not only to the global importance of PM2.5, but also to its focus on the most tested interventions and viable approaches directed at particulate matter air pollution. The writing group sought to provide expert consensus opinions on personal-level measures recognizing the current uncertainty and limited evidence base for many interventions. In doing so, the writing group acknowledges that its intent is to assist other agencies charged with protecting public health, without minimizing the personal choice considerations of an individual who may decide to use these interventions in the face of ongoing air pollution exposure.
Collapse
|