Fang Z, Zhou X, Liao H, Xu H. A meta-analysis of Legionella pneumophila contamination in hospital water systems. Am J Infect Control 2023; 51:1250-1262. [PMID: 37054892 DOI: 10.1016/j.ajic.2023.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/31/2023] [Accepted: 04/01/2023] [Indexed: 04/15/2023]
Abstract
BACKGROUND Legionella pneumophila is a common cause of community-acquired pneumonia. We aimed to determine the pooled rates of L pneumophila contamination in the water environment of the hospital. METHODS We searched PubMed, Embase, Web of Science, Chinese National Knowledge Infrastructure, WangFang and Science Direct, The Cochrane Library, and Science Finder, for relevant studies published until December 2022. Stata 16.0 software was used to determine pooled contamination rates, publication bias, and subgroup analysis. RESULTS Forty-eight eligible articles with a total of 23,640 samples of water were evaluated, and the prevalence of L pneumophila was 41.6%. The results of the subgroup analysis showed that the pollution rate of L pneumophila in hot water (47.6%) was higher than that in other water bodies. The rates of L pneumophila contamination were higher in developed countries (45.2%), culture methods (42.3%), published between 1985 and 2015 (42.9%), and studies with a sample size of less than 100 (53.0%). CONCLUSIONS L pneumophila contamination in medical institutions is still very serious and should be paid attention to, especially in developed countries and hot water tanks.
Collapse
Affiliation(s)
- Zisi Fang
- School of Public Health, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Xiaocong Zhou
- School of Public Health, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Hui Liao
- School of Public Health, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, China
| | - Hong Xu
- Department of Environmental Health, Hangzhou Center for Disease Control and Prevention, Hangzhou, Zhejiang, China.
| |
Collapse
|
2
|
Chen Y, Li X, Gao W, Zhang Y, Mo A, Jiang J, He D. Microfiber-loaded bacterial community in indoor fallout and air-conditioner filter dust. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 856:159211. [PMID: 36206901 DOI: 10.1016/j.scitotenv.2022.159211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/29/2022] [Revised: 09/26/2022] [Accepted: 09/30/2022] [Indexed: 06/16/2023]
Abstract
Microfibers (MFs) are widely existed in indoor air; however, characteristic of microbiota on MFs is largely unknown. In this study, air-borne MFs were collected from fallout or air-conditioner (AC) filter dust in three types of indoor space including living room, dormitory and office. Both plastic and natural MFs were identified by Fourier transform infrared spectroscopy. Ultramicroscopic observation showed dense biofilms adhering on surfaces of MFs. Fallout MFs contained more bacteria but fewer fungi than MFs from AC filter dust. MFs-loaded bacteria were of highest abundance in living rooms, following dormitories and offices. Bacterial community and its diversity were further analyzed by 16S rRNA High-throughput sequencing. Up to 4540 of bacterium OTUs were shared in these MFs samples, unique OTUs in fallout and AC filter samples accounting for 26.3 % and 25.7 % of the total. Compared to MFs fallout, AC filter MFs contained more species of pathogenic bacteria, such as Betaproteobacteriales and Ralstonia, with obviously different β-diversity between two groups. Phenotypic analysis showed that fallout and AC filter MFs bacteria presented high index values of film formation, oxidative stress tolerance and potential pathogenicity. Overall, these results suggest that abundant bacteria including pathogen can be loaded on MFs, and would pose health risks through delivery of indoor MFs.
Collapse
Affiliation(s)
- Yingxin Chen
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China
| | - Xinyu Li
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China
| | - Wei Gao
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China; Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, East China Normal University, Shanghai 200241, China
| | - Yalin Zhang
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China
| | - Aoyun Mo
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China
| | - Jie Jiang
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China; Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, East China Normal University, Shanghai 200241, China
| | - Defu He
- School of Ecological and Environmental Sciences, East China Normal University, Shanghai 200241, China; Shanghai Engineering Research Center of Biotransformation of Organic Solid Waste, East China Normal University, Shanghai 200241, China; Shanghai Key Laboratory for Urban Ecological Processes and Eco-Restoration, East China Normal University, Shanghai 200241, China; Technology Innovation Center for Land Spatial Eco-restoration in Metropolitan Area, Ministry of Natural Resources, Shanghai 200062, China.
| |
Collapse
|
3
|
Abstract
Legionella pneumophila (LP) widely exists in natural and artificial water environments, which facilitates LP to infect people. LP infection causes Legionnaires' disease (LD), which is an important but relatively uncommon respiratory infection. Approximately 90% of LD is caused by L. pneumophila serogroup 1 (Lp1). Meteorological conditions may affect the infectivity and virulence of Lp1, but the exact relationship between them is still unclear. In this study, we evaluated the virulence of Lp1 by screening of total 156 Lp1 strains isolated from cooling tower water in different region of China by detecting their abilities to activate NF-κB signaling pathway in vitro. In addition, we screened the distribution of some selected virulence genes in these strains. The virulence, virulence gene distribution and the meteorological factors were analyzed. We found that both the virulence and the distribution of virulence genes had a certain regional and meteorological correlation. Although loss of several virulence genes showed significant effects on the virulence of Lp1 strains, the distribution of virulence genes had very limited effects on the virulence of Lp1. IMPORTANCE LD is likely to be under-recognized in many countries. Due to the widespread existence of LP in natural and artificial water environments, and to the lack of cross-protection against different strains, LP is a potentially serious threat to human health. Therefore, effective monitoring of the virulence of LP in the water environment is very important to prevent and control the prevalence of LD. Understanding the virulence of LP can not only help us to predict the risk of possible outbreaks in advance, but can also enable more targeted clinical treatment. This study highlights the importance of understanding the epidemiology and ecology of LP isolated from public facilities in terms of public health and biology. Due to the potential for water sources to harbor and disseminate LP, and to the fact that geographical conditions influence the virulence of LP, timely and accurate LP virulence surveillance is urgently needed.
Collapse
|
4
|
Prevalence and Molecular Characteristics of Waterborne Pathogen Legionella in Industrial Cooling Tower Environments. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2015; 12:12605-17. [PMID: 26473896 PMCID: PMC4626988 DOI: 10.3390/ijerph121012605] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/07/2015] [Revised: 09/25/2015] [Accepted: 09/30/2015] [Indexed: 11/17/2022]
Abstract
Cooling towers are a source of Legionnaires' disease. It is important from a public health perspective to survey industrial cooling towers for the presence of Legionella. Prospective surveillance of the extent of Legionella pollution was conducted at factories in Shijiazhuang, China between March 2011 and September 2012. Overall, 35.7% of 255 industrial cooling tower water samples showed Legionella-positive, and their concentrations ranged from 100 Colony-Forming Units (CFU)/liter to 88,000 CFU/liter, with an average concentration of 9100 CFU/liter. A total of 121 isolates were obtained. All isolates were L. pneumophila, and the isolated serogroups included serogroups 1 (68 isolates, 56.2%), 6 (25, 20.7%), 5 (12, 9.9%), 8 (8, 6.6%), 3 (6, 5.0%) and 9 (2, 1.6%). All 121 isolates were analyzed by pulsed-field gel electrophoresis (PFGE) and 64 different patterns were obtained. All 121 isolates were analyzed sequence-based typing (SBT), a full 7-allele profile was obtained from 117 isolates. One hundred and seventeen isolates were divided into 49 sequence types. Two virulence genes, lvh and rtxA, are analyzed by polymerase chain reaction (PCR). 92.6% (112/121) and 98.3% (119/121) isolates carried lvh and rtxA respectively and 90.9% (110/121) of tested isolates carried both genes. Our results demonstrated high prevalence and genetic polymorphism of L. pneumophila in industrial cooling tower environments in Shijiazhang, China, and the SBT and virulence gene PCR results suggested that the isolates were pathogenic. Improved control and prevention strategies are urgently needed.
Collapse
|
5
|
Oana K, Kobayashi M, Yamaki D, Sakurada T, Nagano N, Kawakami Y. Applicability assessment of ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ to the eradication of Legionella in rainwater storage tanks for household use. Int J Nanomedicine 2015; 10:4971-9. [PMID: 26346201 PMCID: PMC4531045 DOI: 10.2147/ijn.s87350] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Water environments appear to be the habitats of Legionella species. Legionellosis is considered as a preventable illness because bacterial reservoirs can be controlled and removed. Roof-harvested rainwater has attracted significant attention not only as a groundwater recharge but also as a potential alternative source of nonpotable water. We successfully developed ceramic microbeads coated with hydroxyapatite-binding silver/titanium dioxide ceramic composite earthplus™ using the thermal spraying method. The ceramic microbeads were demonstrated to have bactericidal activities against not only Legionella but also coliform and heterotrophic bacteria. Immersing the ceramic microbeads in household rainwater storage tanks was demonstrated to yield the favorable eradication of Legionella organisms. Not only rapid-acting but also long-lasting bactericidal activities of the ceramic microbead were exhibited against Legionella pneumophila. However, time-dependent attenuation of the bactericidal activities against Legionella were also noted in the sustainability appraisal experiment. Therefore, the problems to be overcome surely remain in constantly managing the Legionella-pollution by means of immersing the ceramic microbeads. The results of our investigation apparently indicate that the earthplus™-coated ceramic microbeads would become the favorable tool for Legionella measures in household rainwater storage tanks, which may become the natural reservoir for Legionella species. Our investigation would justify further research and data collection to obtain more reliable procedures to microbiologically regulate the Legionella in rainwater storage tanks.
Collapse
Affiliation(s)
- Kozue Oana
- Division of Infection Control and Microbiological Regulation, Department of Health and Medical Sciences, Shinshu University Graduate School of Medicine, Matsumoto, Japan ; Division of Clinical Microbiology, Department of Biomedical Laboratory Sciences, School of Health Sciences, Shinshu University School of Medicine, Matsumoto, Japan
| | - Michiko Kobayashi
- Division of Infection Control and Microbiological Regulation, Department of Health and Medical Sciences, Shinshu University Graduate School of Medicine, Matsumoto, Japan
| | - Dai Yamaki
- Shinshu Ceramics Co., Ltd., Kiso, Nagano, Japan
| | | | - Noriyuki Nagano
- Division of Infection Control and Microbiological Regulation, Department of Health and Medical Sciences, Shinshu University Graduate School of Medicine, Matsumoto, Japan ; Division of Clinical Microbiology, Department of Biomedical Laboratory Sciences, School of Health Sciences, Shinshu University School of Medicine, Matsumoto, Japan
| | - Yoshiyuki Kawakami
- Division of Infection Control and Microbiological Regulation, Department of Health and Medical Sciences, Shinshu University Graduate School of Medicine, Matsumoto, Japan ; Division of Clinical Microbiology, Department of Biomedical Laboratory Sciences, School of Health Sciences, Shinshu University School of Medicine, Matsumoto, Japan
| |
Collapse
|
6
|
Sequence types diversity of Legionella pneumophila isolates from environmental water sources in Guangzhou and Jiangmen, China. INFECTION GENETICS AND EVOLUTION 2015; 29:35-41. [DOI: 10.1016/j.meegid.2014.10.023] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2014] [Revised: 10/17/2014] [Accepted: 10/25/2014] [Indexed: 11/18/2022]
|
7
|
Distribution of sequence-based types of legionella pneumophila serogroup 1 strains isolated from cooling towers, hot springs, and potable water systems in China. Appl Environ Microbiol 2014; 80:2150-7. [PMID: 24463975 DOI: 10.1128/aem.03844-13] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
Legionella pneumophila serogroup 1 causes Legionnaires' disease. Water systems contaminated with Legionella are the implicated sources of Legionnaires' disease. This study analyzed L. pneumophila serogroup 1 strains in China using sequence-based typing. Strains were isolated from cooling towers (n = 96), hot springs (n = 42), and potable water systems (n = 26). Isolates from cooling towers, hot springs, and potable water systems were divided into 25 sequence types (STs; index of discrimination [IOD], 0.711), 19 STs (IOD, 0.934), and 3 STs (IOD, 0.151), respectively. The genetic variation among the potable water isolates was lower than that among cooling tower and hot spring isolates. ST1 was the predominant type, accounting for 49.4% of analyzed strains (n = 81), followed by ST154. With the exception of two strains, all potable water isolates (92.3%) belonged to ST1. In contrast, 53.1% (51/96) and only 14.3% (6/42) of cooling tower and hot spring, respectively, isolates belonged to ST1. There were differences in the distributions of clone groups among the water sources. The comparisons among L. pneumophila strains isolated in China, Japan, and South Korea revealed that similar clones (ST1 complex and ST154 complex) exist in these countries. In conclusion, in China, STs had several unique allelic profiles, and ST1 was the most prevalent sequence type of environmental L. pneumophila serogroup 1 isolates, similar to its prevalence in Japan and South Korea.
Collapse
|
8
|
Conza L, Pagani SC, Gaia V. Presence of Legionella and free-living Amoebae in composts and bioaerosols from composting facilities. PLoS One 2013; 8:e68244. [PMID: 23844174 PMCID: PMC3699541 DOI: 10.1371/journal.pone.0068244] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2013] [Accepted: 05/22/2013] [Indexed: 11/24/2022] Open
Abstract
Several species of Legionella cause Legionnaires' disease (LD). Infection may occur through inhalation of Legionella or amoebal vesicles. The reservoirs of Legionella are water, soil, potting soil and compost. Some species of free-living amoebae (FLA) that are naturally present in water and soil were described as hosts for Legionella. This study aimed to understand whether or not the composting facilities could be sources of community-acquired Legionella infections after development of bioaerosols containing Legionella or FLA. We looked for the presence of Legionella (by co-culture) and FLA (by culture) in composts and bioaerosols collected at four composting facilities located in southern Switzerland. We investigated the association between the presence of Legionella and compost and air parameters and presence of FLA. Legionella spp. (including L. pneumophila) were detected in 69.3% (61/88) of the composts and FLA (mainly Acanthamoeba, Vermamoeba, Naegleria and Stenamoeba) in 92.0% (81/88). L. pneumophila and L. bozemanii were most frequently isolated. FLA as potential host for Legionella spp. were isolated from 40.9% (36/88) of the composts in all facilities. In Legionella-positive samples the temperature of compost was significantly lower (P = 0.012) than in Legionella-negative samples. Of 47 bioaerosol samples, 19.1% (9/47) were positive for FLA and 10.6% (5/47) for L. pneumophila. Composts (62.8%) were positive for Legionella and FLA contemporaneously, but both microorganisms were never detected simultaneously in bioaerosols. Compost can release bioaerosol containing FLA or Legionella and could represent a source of infection of community-acquired Legionella infections for workers and nearby residents.
Collapse
Affiliation(s)
- Lisa Conza
- Swiss National Reference Centre for Legionella, Cantonal Institute of Microbiology, Bellinzona, Switzerland.
| | | | | |
Collapse
|
9
|
Qin T, Yan G, Ren H, Zhou H, Wang H, Xu Y, Zhao M, Guan H, Li M, Shao Z. High prevalence, genetic diversity and intracellular growth ability of Legionella in hot spring environments. PLoS One 2013; 8:e59018. [PMID: 23527075 PMCID: PMC3601096 DOI: 10.1371/journal.pone.0059018] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2013] [Accepted: 02/09/2013] [Indexed: 11/18/2022] Open
Abstract
Background Legionella is the causative agent of Legionnaires' disease, and hot springs are a major source of outbreaks of this disease. It is important from a public health perspective to survey hot spring environments for the presence of Legionella. Methods Prospective surveillance of the extent of Legionella pollution was conducted at three hot spring recreational areas in Beijing, China in 2011. Pulsed-field gel electrophoresis (PFGE) and sequence-based typing (SBT) were used to describe the genetic polymorphism of isolates. The intracellular growth ability of the isolates was determined by interacting with J774 cells and plating the dilutions onto BCYE agar plates. Results Overall, 51.9% of spring water samples showed Legionella-positive, and their concentrations ranged from 1 CFU/liter to 2,218 CFU/liter. The positive rates of Legionella were significantly associated with a free chlorine concentration of ≥0.2 mg/L, urea concentration of ≥0.05 mg/L, total microbial counts of ≥400 CFU/ml and total coliform of ≥3 MPN/L (p<0.01). The Legionella concentrations were significantly associated with sample temperature, pH, total microbial counts and total coliform (p<0.01). Legionella pneumophila was the most frequently isolated species (98.9%), and the isolated serogroups included serogroups 3 (25.3%), 6 (23.4%), 5 (19.2%), 1 (18.5%), 2 (10.2%), 8 (0.4%), 10 (0.8%), 9 (1.9%) and 12 (0.4%). Two hundred and twenty-eight isolates were analyzed by PFGE and 62 different patterns were obtained. Fifty-seven L. pneumophila isolates were selected for SBT analysis and divided into 35 different sequence types with 5 main clonal groups. All the 57 isolates had high intracellular growth ability. Conclusions Our results demonstrated high prevalence and genetic polymorphism of Legionella in springs in Beijing, China, and the SBT and intracellular growth assay results suggested that the Legionella isolates of hot spring environments were pathogenic. Improved control and prevention strategies are urgently needed.
Collapse
Affiliation(s)
- Tian Qin
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
- * E-mail: (TQ); (ZS)
| | - Gebin Yan
- Changping District Center for Disease Control and Prevention, Changping, Beijing, China
| | - Hongyu Ren
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
| | - Haijian Zhou
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
| | - Huanxin Wang
- Changping District Center for Disease Control and Prevention, Changping, Beijing, China
| | - Ying Xu
- Changping District Center for Disease Control and Prevention, Changping, Beijing, China
| | - Mingqiang Zhao
- Changping District Center for Disease Control and Prevention, Changping, Beijing, China
| | - Hong Guan
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
| | - Machao Li
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
| | - Zhujun Shao
- State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Changping, Beijing, China
- * E-mail: (TQ); (ZS)
| |
Collapse
|
10
|
Conza L, Casati S, Limoni C, Gaia V. Meteorological factors and risk of community-acquired Legionnaires' disease in Switzerland: an epidemiological study. BMJ Open 2013; 3:e002428. [PMID: 23468470 PMCID: PMC3612760 DOI: 10.1136/bmjopen-2012-002428] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2012] [Revised: 01/17/2013] [Accepted: 01/31/2013] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVES The aim of this study was to identify meteorological factors that could be associated with an increased risk of community-acquired Legionnaires' disease (LD) in two Swiss regions. DESIGN Retrospective epidemiological study using discriminant analysis and multivariable Poisson regression. SETTING We analysed legionellosis cases notified between January 2003 and December 2007 and we looked for a possible relationship between incidence rate and meteorological factors. PARTICIPANTS Community-acquired LD cases in two Swiss regions, the Canton Ticino and the Basle region, with climatically different conditions were investigated. PRIMARY OUTCOME MEASURES Vapour pressure, temperature, relative humidity, wind, precipitation and radiation recorded in weather stations of the two Swiss regions during the period January 2003 and December 2007. RESULTS Discriminant analysis showed that the two regions are characterised by different meteorological conditions. A multiple Poisson regression analysis identified region, temperature and vapour pressure during the month of infection as significant risk factors for legionellosis. The risk of developing LD was 129.5% (or 136.4% when considering vapour pressure instead of temperature in the model) higher in the Canton Ticino as compared to the Basle region. There was an increased relative risk of LD by 11.4% (95% CI 7.70% to 15.30%) for each 1 hPa rise of vapour pressure or by 6.7% (95% CI 4.22% to 9.22%) for 1°C increase of temperature. CONCLUSIONS In this study, higher water vapour pressure and heat were associated with a higher risk of community-acquired LD in two regions of Switzerland.
Collapse
Affiliation(s)
- Lisa Conza
- Swiss National Reference Centre for Legionella, Cantonal Institute of Microbiology, Bellinzona, Switzerland
| | - Simona Casati
- Swiss National Reference Centre for Legionella, Cantonal Institute of Microbiology, Bellinzona, Switzerland
| | - Costanzo Limoni
- Alpha5, Biometrics & Data Management, Riva San Vitale, Switzerland
| | - Valeria Gaia
- Swiss National Reference Centre for Legionella, Cantonal Institute of Microbiology, Bellinzona, Switzerland
| |
Collapse
|
11
|
Lee HK, Shim JI, Kim HE, Yu JY, Kang YH. Distribution of Legionella species from environmental water sources of public facilities and genetic diversity of L. pneumophila serogroup 1 in South Korea. Appl Environ Microbiol 2010; 76:6547-54. [PMID: 20693456 PMCID: PMC2950455 DOI: 10.1128/aem.00422-10] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2010] [Accepted: 07/06/2010] [Indexed: 01/19/2023] Open
Abstract
A total of 560 Legionella species were isolated from environmental water sources from public facilities from June to September 2008 throughout South Korea. The distribution of Legionella isolates was investigated according to geographical region, facility type, and sample type. The genetic diversity of 104 isolates of Legionella pneumophila serogroup 1 (sg 1) was analyzed by sequence-based typing (SBT). L. pneumophila was distributed broadly throughout Korea, accounting for 85.0% of the isolates, and L. pneumophila sg 1 predominated in all of the public facilities except for the springs. Legionella anisa and Legionella bozemanii predominated among non-L. pneumophila species (48.1% and 21.0%, respectively). The second most dominant strain differed depending on the facility type: L. anisa was the second most dominant strain in the buildings (10.8%), L. pneumophila sg 5 in public baths (21.6%), L. pneumophila sg 6 in factories (12.0%), and L. pneumophila sg 7 in hospitals (13.1%). In the SBT analysis, 104 L. pneumophila sg 1 isolates were differentiated into 26 sequence types (STs) and categorized into 3 clonal groups (CGs) and 10 singleton STs via the eBURST V3 program. ST1, a potential founder of major CG1, was commonly distributed (48.1%). The dominant ST in hot water was ST-K1 (7, 12, 17, 3, 35, 11, 11), which was designated in this study (36.1%). The second most dominant strain differed depending on the type of facility from which the samples were obtained. The unique allelic profile of ST-K1, obtained from hot water, was not found in the European Working Group for Legionella Infections (EWGLI) SBT database.
Collapse
Affiliation(s)
- Hae Kyung Lee
- Division of Bacterial Respiratory Infections, Center for Infectious Diseases, National Institute of Health, Centers for Disease Control and Prevention, Seoul, Republic of Korea
| | - Jung Im Shim
- Division of Bacterial Respiratory Infections, Center for Infectious Diseases, National Institute of Health, Centers for Disease Control and Prevention, Seoul, Republic of Korea
| | - Hye Eun Kim
- Division of Bacterial Respiratory Infections, Center for Infectious Diseases, National Institute of Health, Centers for Disease Control and Prevention, Seoul, Republic of Korea
| | - Jae Yon Yu
- Division of Bacterial Respiratory Infections, Center for Infectious Diseases, National Institute of Health, Centers for Disease Control and Prevention, Seoul, Republic of Korea
| | - Yeon Ho Kang
- Division of Bacterial Respiratory Infections, Center for Infectious Diseases, National Institute of Health, Centers for Disease Control and Prevention, Seoul, Republic of Korea
| |
Collapse
|