1
|
Shiraki T, Niidome Y, Roy A, Berggren M, Simon DT, Stavrinidou E, Méhes G. Single-walled Carbon Nanotubes Wrapped with Charged Polysaccharides Enhance Extracellular Electron Transfer. ACS APPLIED BIO MATERIALS 2024; 7:5651-5661. [PMID: 39077871 PMCID: PMC11337164 DOI: 10.1021/acsabm.4c00749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/18/2024] [Accepted: 07/21/2024] [Indexed: 07/31/2024]
Abstract
Microbial electrochemical systems (MESs) rely on the microbes' ability to transfer charges from their anaerobic respiratory processes to electrodes through extracellular electron transfer (EET). To increase the generally low output signal in devices, advanced bioelectrical interfaces tend to augment this problem by attaching conducting nanoparticles, such as positively charged multiwalled carbon nanotubes (CNTs), to the base carbon electrode to electrostatically attract the negatively charged bacterial cell membrane. On the other hand, some reports point to the importance of the magnitude of the surface charge of functionalized single-walled CNTs (SWCNTs) as well as the size of functional groups for interaction with the cell membrane, rather than their polarity. To shed light on these phenomena, in this study, we prepared and characterized well-solubilized aqueous dispersions of SWCNTs functionalized by either positively or negatively charged cellulose-derivative polymers, as well as with positively charged or neutral small molecular surfactants, and tested the electrochemical performance of Shewanella oneidensis MR-1 in MESs in the presence of these functionalized SWCNTs. By simple injection into the MESs, the positively charged polymeric SWCNTs attached to the base carbon felt (CF) electrode, and as fluorescence microscopy revealed, allowed bacteria to attach to these structures. As a result, EET currents continuously increased over several days of monitoring, without bacterial growth in the electrolyte. Negatively charged polymeric SWCNTs also resulted in continuously increasing EET currents and a large number of bacteria on CF, although SWCNTs did not attach to CF. In contrast, SWCNTs functionalized by small-sized surfactants led to a decrease in both currents and the amount of bacteria in the solution, presumably due to the detachment of surfactants from SWCNTs and their detrimental interaction with cells. We expect our results will help researchers in designing materials for smart bioelectrical interfaces for low-scale microbial energy harvesting, sensing, and energy conversion applications.
Collapse
Affiliation(s)
- Tomohiro Shiraki
- Department
of Applied Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
- International
Institute for Carbon-Neutral Energy Research (WPI-I2CNER), Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Yoshiaki Niidome
- Department
of Applied Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Arghyamalya Roy
- Laboratory
of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
| | - Magnus Berggren
- Laboratory
of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
- Wallenberg
Wood Science Center, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
| | - Daniel T. Simon
- Laboratory
of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
| | - Eleni Stavrinidou
- Laboratory
of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
- Wallenberg
Wood Science Center, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
| | - Gábor Méhes
- Laboratory
of Organic Electronics, Department of Science and Technology, Linköping University, Bredgatan 33, Norrköping 601 74, Sweden
- Graduate
School of Information, Production and Systems, Waseda University, Hibikino
2-7, Wakamatsu, Kitakyushu 808-0135, Japan
| |
Collapse
|
2
|
Tseng CP, Liu F, Zhang X, Huang PC, Campbell I, Li Y, Atkinson JT, Terlier T, Ajo-Franklin CM, Silberg JJ, Verduzco R. Solution-Deposited and Patternable Conductive Polymer Thin-Film Electrodes for Microbial Bioelectronics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2109442. [PMID: 35088918 DOI: 10.1002/adma.202109442] [Citation(s) in RCA: 23] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 01/21/2022] [Indexed: 06/14/2023]
Abstract
Microbial bioelectronic devices integrate naturally occurring or synthetically engineered electroactive microbes with microelectronics. These devices have a broad range of potential applications, but engineering the biotic-abiotic interface for biocompatibility, adhesion, electron transfer, and maximum surface area remains a challenge. Prior approaches to interface modification lack simple processability, the ability to pattern the materials, and/or a significant enhancement in currents. Here, a novel conductive polymer coating that significantly enhances current densities relative to unmodified electrodes in microbial bioelectronics is reported. The coating is based on a blend of poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT:PSS) crosslinked with poly(2-hydroxyethylacrylate) (PHEA) along with a thin polydopamine (PDA) layer for adhesion to an underlying indium tin oxide (ITO) electrode. When used as an interface layer with the current-producing bacterium Shewanella oneidensis MR-1, this material produces a 178-fold increase in the current density compared to unmodified electrodes, a current gain that is higher than previously reported thin-film 2D coatings and 3D conductive polymer coatings. The chemistry, morphology, and electronic properties of the coatings are characterized and the implementation of these coated electrodes for use in microbial fuel cells, multiplexed bioelectronic devices, and organic electrochemical transistor based microbial sensors are demonstrated. It is envisioned that this simple coating will advance the development of microbial bioelectronic devices.
Collapse
Affiliation(s)
- Chia-Ping Tseng
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX, 77005, USA
| | - Fangxin Liu
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX, 77005, USA
| | - Xu Zhang
- Department of BioSciences, Rice University, Houston, TX, 77005, USA
| | - Po-Chun Huang
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX, 77005, USA
| | - Ian Campbell
- Department of BioSciences, Rice University, Houston, TX, 77005, USA
| | - Yilin Li
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX, 77005, USA
| | - Joshua T Atkinson
- Department of Physics and Astronomy, University of Southern California, Los Angeles, CA, 90007, USA
| | - Tanguy Terlier
- SIMS Laboratory, Shared Equipment Authority, Rice University, Houston, TX, 77005, USA
| | | | | | - Rafael Verduzco
- Department of Chemical and Biomolecular Engineering, Rice University, Houston, TX, 77005, USA
- Department of Materials Science and NanoEngineering, Rice University, Houston, TX, 77005, USA
| |
Collapse
|
3
|
Méhes G, Roy A, Strakosas X, Berggren M, Stavrinidou E, Simon DT. Organic Microbial Electrochemical Transistor Monitoring Extracellular Electron Transfer. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2020; 7:2000641. [PMID: 32775155 PMCID: PMC7404149 DOI: 10.1002/advs.202000641] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 05/08/2020] [Indexed: 05/11/2023]
Abstract
Extracellular electron transfer (EET) denotes the process of microbial respiration with electron transfer to extracellular acceptors and has been exploited in a range of microbial electrochemical systems (MESs). To further understand EET and to optimize the performance of MESs, a better understanding of the dynamics at the microscale is needed. However, the real-time monitoring of EET at high spatiotemporal resolution would require sophisticated signal amplification. To amplify local EET signals, a miniaturized bioelectronic device, the so-called organic microbial electrochemical transistor (OMECT), is developed, which includes Shewanella oneidensis MR-1 integrated onto organic electrochemical transistors comprising poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) combined with poly(vinyl alcohol) (PVA). Bacteria are attached to the gate of the transistor by a chronoamperometric method and the successful attachment is confirmed by fluorescence microscopy. Monitoring EET with the OMECT configuration is achieved due to the inherent amplification of the transistor, revealing fast time-responses to lactate. The limits of detection when using microfabricated gates as charge collectors are also investigated. The work is a first step toward understanding and monitoring EET in highly confined spaces via microfabricated organic electronic devices, and it can be of importance to study exoelectrogens in microenvironments, such as those of the human microbiome.
Collapse
Affiliation(s)
- Gábor Méhes
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| | - Arghyamalya Roy
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| | - Xenofon Strakosas
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| | - Magnus Berggren
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
- Wallenberg Wood Science CenterDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| | - Eleni Stavrinidou
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
- Wallenberg Wood Science CenterDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| | - Daniel T. Simon
- Laboratory of Organic ElectronicsDepartment of Science and TechnologyLinköping UniversityNorrköping60174Sweden
| |
Collapse
|
4
|
Cornejo JA, Sheng H, Edri E, M Ajo-Franklin C, Frei H. Nanoscale membranes that chemically isolate and electronically wire up the abiotic/biotic interface. Nat Commun 2018; 9:2263. [PMID: 29891950 PMCID: PMC5995903 DOI: 10.1038/s41467-018-04707-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 05/11/2018] [Indexed: 01/02/2023] Open
Abstract
By electrochemically coupling microbial and abiotic catalysts, bioelectrochemical systems such as microbial electrolysis cells and microbial electrosynthesis systems synthesize energy-rich chemicals from energy-poor precursors with unmatched efficiency. However, to circumvent chemical incompatibilities between the microbial cells and inorganic materials that result in toxicity, corrosion, fouling, and efficiency-degrading cross-reactions between oxidation and reduction environments, bioelectrochemical systems physically separate the microbial and inorganic catalysts by macroscopic distances, thus introducing ohmic losses, rendering these systems impractical at scale. Here we electrochemically couple an inorganic catalyst, a SnO2 anode, with a microbial catalyst, Shewanella oneidensis, via a 2-nm-thick silica membrane containing -CN and -NO2 functionalized p-oligo(phenylene vinylene) molecular wires. This membrane enables electron flow at 0.51 μA cm-2 from microbial catalysts to the inorganic anode, while blocking small molecule transport. Thus the modular architecture avoids chemical incompatibilities without ohmic losses and introduces an immense design space for scale up of bioelectrochemical systems.
Collapse
Affiliation(s)
- Jose A Cornejo
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA
| | - Hua Sheng
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA
| | - Eran Edri
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA.,Department of Chemical Engineering, Ben-Gurion University of the Negev Be'er Sheva, 8410501, Beersheba, Israel
| | - Caroline M Ajo-Franklin
- Molecular Foundry Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA. .,Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA.
| | - Heinz Frei
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, University of California, Berkeley, CA, 94720, USA.
| |
Collapse
|
5
|
Kumar G, Waters MS, Farooque TM, Young MF, Simon CG. Freeform fabricated scaffolds with roughened struts that enhance both stem cell proliferation and differentiation by controlling cell shape. Biomaterials 2012; 33:4022-30. [PMID: 22417619 PMCID: PMC3428138 DOI: 10.1016/j.biomaterials.2012.02.048] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2012] [Accepted: 02/26/2012] [Indexed: 11/20/2022]
Abstract
We demonstrate that freeform fabricated (FFF) scaffolds with a roughened surface topography can support hBMSC proliferation, while also inducing osteogenic differentiation, for maximized generation of calcified, bone-like tissue. Previously, hBMSCs rapidly proliferated, without osteogenic differentiation, during culture in FFF scaffolds. In contrast, hBMSCs underwent osteogenic differentiation, with slow proliferation, during culture in nanofiber scaffolds. Analysis of cell morphology showed that the topography presented by the nanofiber scaffolds drove hBMSC differentiation by guiding them into a morphology that induced osteogenic differentiation. Herein, we hypothesized that using the high-surface area architecture of FFF scaffolds to present a surface roughness that drives hBMSCs into a morphology that induces osteogenic differentiation would yield a maximum amount differentiated hBMSCs and bone-like tissue. Thus, a solvent etching method was developed that imparted a 5-fold increase in roughness to the surface of the struts of poly(ε-caprolactone) (PCL) FFF scaffolds. The etched scaffolds induced osteogenic differentiation of the hBMSCs while un-etched scaffolds did not. The etched scaffolds also supported the same high levels of hBMSC proliferation that un-etched scaffolds supported. Finally, hBMSCs on un-etched scaffolds had a large spread area, while hBMSCs on etched scaffolds has a smaller area and were more rounded, indicating that the surface roughness from the etched scaffolds dictated the morphology of the hBMSCs. The results demonstrate that FFF scaffolds with surface roughness can support hBMSC proliferation, while also inducing osteogenic differentiation, to maximize generation of calcified tissue. This work validates a rational approach to scaffold fabrication where the structure of the scaffold was designed to optimize stem cell function by controlling cell morphology.
Collapse
Affiliation(s)
- Girish Kumar
- Polymers Division, National Institute of Standards & Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA
- National Institute of Dental & Craniofacial Research, National Institutes of Health, 30 Convent Drive, Bethesda, MD, 20892, USA
- Division of Biology, Office of Science & Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food & Drug Administration, 10903 New Hampshire Ave, Silver Spring, MD, 20993, USA
| | - Michael S. Waters
- Polymers Division, National Institute of Standards & Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA
| | - Tanya M. Farooque
- Polymers Division, National Institute of Standards & Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA
| | - Marian F. Young
- National Institute of Dental & Craniofacial Research, National Institutes of Health, 30 Convent Drive, Bethesda, MD, 20892, USA
| | - Carl G. Simon
- Polymers Division, National Institute of Standards & Technology, 100 Bureau Drive, Gaithersburg, MD, 20899, USA
| |
Collapse
|
6
|
Waters MS, El-Naggar MY, Hsu L, Sturm CA, Luttge A, Udwadia FE, Cvitkovitch DG, Goodman SD, Nealson KH. Simultaneous interferometric measurement of corrosive or demineralizing bacteria and their mineral interfaces. Appl Environ Microbiol 2009; 75:1445-9. [PMID: 19124590 PMCID: PMC2648148 DOI: 10.1128/aem.02039-08] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2008] [Accepted: 12/26/2008] [Indexed: 11/20/2022] Open
Abstract
Here, we report simultaneous surface profile measurements of several bacterial species involved in microbially influenced corrosion and their solid-surface interfaces by using vertical scanning interferometry. The capacity to nondestructively quantify microscale topographic changes beneath a single bacterium without its removal offers a unique opportunity to examine in vivo microbe-surface interactions.
Collapse
Affiliation(s)
- M S Waters
- University of Southern California, Department of Molecular and Computational Biology, 1050 Childs Way MCB 201B, Los Angeles, California 90089-2910, USA
| | | | | | | | | | | | | | | | | |
Collapse
|