1
|
Hajarolasvadi S, Khaleghimeybodi M, Razavi P, Smirnov M, Prepeliă ST. Effect of sound-induced vibrations of the pinna on head-related transfer functions: Experimental and numerical investigations. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 155:2875-2890. [PMID: 38682913 DOI: 10.1121/10.0025773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Accepted: 04/04/2024] [Indexed: 05/01/2024]
Abstract
Numerical simulations of head-related transfer functions (HRTFs) conventionally assume a rigid boundary condition for the pinna. The human pinna, however, is an elastic deformable body that can vibrate due to incident acoustic waves. This work investigates how sound-induced vibrations of the pinna can affect simulated HRTF magnitudes. The work will motivate the research question by measuring the sound-induced vibrational patterns of an artificial pinna with a high-speed holographic interferometric system. Then, finite element simulations are used to determine HRTFs for a tabletop model of the B&K 5128 head and torso simulator for a number of directions. Two scenarios are explored: one where the pinna is modeled as perfectly rigid, and another where the pinna is modeled as linear elastic with material properties close to that of auricular cartilage. The findings suggest that pinna vibrations have negligible effects on HRTF magnitudes up to 5 kHz. The same conclusion, albeit with less certainty, is drawn for higher frequencies. Finally, the importance of the elastic domain's material properties is emphasized and possible implications for validation studies on dummy heads 1as well as the limitations of the present work are discussed in detail.
Collapse
Affiliation(s)
- Setare Hajarolasvadi
- Reality Labs Research at Meta, 8747 Willows Road, Redmond, Washington 98052, USA
| | | | - Payam Razavi
- Reality Labs Research at Meta, 8747 Willows Road, Redmond, Washington 98052, USA
| | - Michael Smirnov
- Reality Labs Research at Meta, 8747 Willows Road, Redmond, Washington 98052, USA
| | - Sebastian T Prepeliă
- Reality Labs Research at Meta, 8747 Willows Road, Redmond, Washington 98052, USA
| |
Collapse
|
2
|
Ugarteburu M, Withnell RH, Cardoso L, Carriero A, Richter CP. Mammalian middle ear mechanics: A review. Front Bioeng Biotechnol 2022; 10:983510. [PMID: 36299283 PMCID: PMC9589510 DOI: 10.3389/fbioe.2022.983510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 09/20/2022] [Indexed: 11/13/2022] Open
Abstract
The middle ear is part of the ear in all terrestrial vertebrates. It provides an interface between two media, air and fluid. How does it work? In mammals, the middle ear is traditionally described as increasing gain due to Helmholtz’s hydraulic analogy and the lever action of the malleus-incus complex: in effect, an impedance transformer. The conical shape of the eardrum and a frequency-dependent synovial joint function for the ossicles suggest a greater complexity of function than the traditional view. Here we review acoustico-mechanical measurements of middle ear function and the development of middle ear models based on these measurements. We observe that an impedance-matching mechanism (reducing reflection) rather than an impedance transformer (providing gain) best explains experimental findings. We conclude by considering some outstanding questions about middle ear function, recognizing that we are still learning how the middle ear works.
Collapse
Affiliation(s)
- Maialen Ugarteburu
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
| | - Robert H. Withnell
- Department of Speech, Language and Hearing Sciences, Indiana University, Bloomington, IN, United States
| | - Luis Cardoso
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
| | - Alessandra Carriero
- Department of Biomedical Engineering, The City College of New York, New York, NY, United States
- *Correspondence: Alessandra Carriero, ; Claus-Peter Richter,
| | - Claus-Peter Richter
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
- Department of Biomedical Engineering, Northwestern University, Chicago, IL, United States
- Department of Communication Sciences and Disorders, Northwestern University, Chicago, IL, United States
- The Hugh Knowles Center, Northwestern University, Chicago, IL, United States
- *Correspondence: Alessandra Carriero, ; Claus-Peter Richter,
| |
Collapse
|
3
|
Abdalla MKTM, Bassiony MA, Aziz MT, Shewel YG. Effect of loading of the central part of the tympanic membrane on pure tone audiometry. ACTA OTORHINOLARYNGOLOGICA ITALICA 2018; 38:229-235. [PMID: 29984800 DOI: 10.14639/0392-100x-1457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Accepted: 06/23/2017] [Indexed: 11/23/2022]
Abstract
SUMMARY This study was conducted to determine the effects of loading of the central part of the tympanic membrane by different weights on pure tone audiometry of healthy ears. Sixty patients with normal otoscopic view, normal pure tone audiometry and wide external auditory canal to allow direct and endoscopic visualization of TM, but without any history of ear surgeries, were selected and divided equally and randomly into two groups. Loading of the central part of the TM was carried out using weights ranging from [(1 λ) 13.6 mg] to [(40 λ) 544 mg]; (λ) is a symbol for the weight of 1 microliter of mercury. The study was carried out in two steps assisted by direct oto-endoscopy, and pure tone audiometry was used to measure the effects of loading on both air and bone conduction hearing. Air conduction hearing thresholds increased in a statistically significant pattern at low frequencies, 500 Hz, 1000 Hz and 2000 Hz, when the TM was loaded by 340 mg (25 λ). The maximal effect was recorded at 544 mg (40 λ), which affected air conduction hearing at all tested frequencies (500 Hz, 1000 Hz, 2000 Hz and 4000 Hz). However, no statistically significant effect was detected on bone conduction hearing thresholds throughout the study. In conclusion, loading of the tympanic membrane by different masses affects the air conduction hearing threshold by only 340 mg (25 λ), which is very large in comparison to the mass of ossicles, without any significant effects on bone conduction hearing.
Collapse
Affiliation(s)
- M K T M Abdalla
- Department of Otorhinolaryngology, Head and Neck Surgery, Alexandria University, Alexandria, Egypt
| | - M A Bassiony
- Department of Otorhinolaryngology, Head and Neck Surgery, Alexandria University, Alexandria, Egypt
| | - M T Aziz
- Department of Otorhinolaryngology, Head and Neck Surgery, Alexandria University, Alexandria, Egypt
| | - Y G Shewel
- Department of Otorhinolaryngology, Head and Neck Surgery, Alexandria University, Alexandria, Egypt
| |
Collapse
|
4
|
Zhang X, Guan X, Nakmali D, Palan V, Pineda M, Gan RZ. Experimental and modeling study of human tympanic membrane motion in the presence of middle ear liquid. J Assoc Res Otolaryngol 2014; 15:867-81. [PMID: 25106467 DOI: 10.1007/s10162-014-0482-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Accepted: 07/18/2014] [Indexed: 10/24/2022] Open
Abstract
Vibration of the tympanic membrane (TM) has been measured at the umbo using laser Doppler vibrometry and analyzed with finite element (FE) models of the human ear. Recently, full-field TM surface motion has been reported using scanning laser Doppler vibrometry, holographic interferometry, and optical coherence tomography. Technologies for imaging human TM motion have the potential to lead to using a dedicated clinical diagnosis tool for identification of middle ear diseases. However, the effect of middle ear fluid (liquid) on TM surface motion is still not clear. In this study, a scanning laser Doppler vibrometer was used to measure the full-field surface motion of the TM from four human temporal bones. TM displacements were measured under normal and disease-mimicking conditions with different middle ear liquid levels over frequencies ranging from 0.2 to 8 kHz. An FE model of the human ear, including the ear canal, middle ear, and spiral cochlea was used to simulate the motion of the TM in normal and disease-mimicking conditions. The results from both experiments and FE model show that a simple deflection shape with one or two major displacement peak regions of the TM in normal ear was observed at low frequencies (1 kHz and below) while complicated ring-like pattern of the deflection shapes appeared at higher frequencies (4 kHz and above). The liquid in middle ear mainly affected TM deflection shapes at the frequencies higher than 1 kHz.
Collapse
Affiliation(s)
- Xiangming Zhang
- School of Aerospace and Mechanical Engineering and Bioengineering Center, University of Oklahoma, 865 Asp Avenue, Room 200, Norman, OK, 73019, USA,
| | | | | | | | | | | |
Collapse
|
5
|
Bergevin C, Olson ES. External and middle ear sound pressure distribution and acoustic coupling to the tympanic membrane. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2014; 135:1294-312. [PMID: 24606269 PMCID: PMC3985947 DOI: 10.1121/1.4864475] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Sound energy is conveyed to the inner ear by the diaphanous, cone-shaped tympanic membrane (TM). The TM moves in a complex manner and transmits sound signals to the inner ear with high fidelity, pressure gain, and a short delay. Miniaturized sensors allowing high spatial resolution in small spaces and sensitivity to high frequencies were used to explore how pressure drives the TM. Salient findings are: (1) A substantial pressure drop exists across the TM, and varies in frequency from ∼10 to 30 dB. It thus appears reasonable to approximate the drive to the TM as being defined solely by the pressure in the ear canal (EC) close to the TM. (2) Within the middle ear cavity (MEC), spatial variations in sound pressure could vary by more than 20 dB, and the MEC pressure at certain locations/frequencies was as large as in the EC. (3) Spatial variations in pressure along the TM surface on the EC-side were typically less than 5 dB up to 50 kHz. Larger surface variations were observed on the MEC-side.
Collapse
Affiliation(s)
- Christopher Bergevin
- Department of Physics & Astronomy, York University, Toronto, Ontario M3J1P3, Canada
| | - Elizabeth S Olson
- Department of Otolaryngology & Head and Neck Surgery, Department of Biomedical Engineering, Columbia University, 630 West 168th Street, P&S 11-452 New York, New York 10032
| |
Collapse
|
6
|
Cheng JT, Hamade M, Merchant SN, Rosowski JJ, Harrington E, Furlong C. Wave motion on the surface of the human tympanic membrane: holographic measurement and modeling analysis. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:918-37. [PMID: 23363110 PMCID: PMC3574078 DOI: 10.1121/1.4773263] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Sound-induced motions of the surface of the tympanic membrane (TM) were measured using stroboscopic holography in cadaveric human temporal bones at frequencies between 0.2 and 18 kHz. The results are consistent with the combination of standing-wave-like modal motions and traveling-wave-like motions on the TM surface. The holographic techniques also quantified sound-induced displacements of the umbo of the malleus, as well as volume velocity of the TM. These measurements were combined with sound-pressure measurements near the TM to compute middle-ear input impedance and power reflectance at the TM. The results are generally consistent with other published data. A phenomenological model that behaved qualitatively like the data was used to quantify the relative magnitude and spatial frequencies of the modal and traveling-wave-like displacement components on the TM surface. This model suggests the modal magnitudes are generally larger than those of the putative traveling waves, and the computed wave speeds are much slower than wave speeds predicted by estimates of middle-ear delay. While the data are inconsistent with simple modal displacements of the TM, an alternate model based on the combination of modal motions in a lossy membrane can also explain these measurements without invoking traveling waves.
Collapse
Affiliation(s)
- Jeffrey Tao Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114, USA.
| | | | | | | | | | | |
Collapse
|
7
|
Furlong C, Dobrev I, Rosowski J, Cheng J. Assessing eardrum deformation by digital holography. SPIE NEWSROOM 2013:10.1117/2.1201212.004612. [PMID: 24375240 PMCID: PMC3872068 DOI: 10.1117/2.1201212.004612] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
A novel system measures the structure, shape, and acoustically induced changes to the membrane of the human middle ear, to help diagnose and treat hearing disorders.
Collapse
Affiliation(s)
- Cosme Furlong
- Department of Mechanical Engineering Worcester Polytechnic Institute Worcester, MA
| | - Ivo Dobrev
- Department of Mechanical Engineering Worcester Polytechnic Institute Worcester, MA
| | - John Rosowski
- Eaton-Peabody Laboratory Massachusetts Eye and Ear Infirmary Boston, MA
| | - Jeffrey Cheng
- Eaton-Peabody Laboratory Massachusetts Eye and Ear Infirmary Boston, MA
| |
Collapse
|
8
|
Solís SM, Hernández-Montes MDS, Santoyo FM. Tympanic membrane contour measurement with two source positions in digital holographic interferometry. BIOMEDICAL OPTICS EXPRESS 2012; 3:3203-10. [PMID: 23243570 PMCID: PMC3521304 DOI: 10.1364/boe.3.003203] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 10/18/2012] [Accepted: 11/04/2012] [Indexed: 05/03/2023]
Abstract
The data acquisition from the shape of an object is a must to complete its quantitative displacement measurement analysis. Over the past years whole field of view optical non-invasive testing has been widely used in many areas, from industrial ones to, for instance, biomedical research topics. To measure the surface contour from the tympanic membrane (TM) of ex-vivo cats digital holographic interferometry (DHI) is used in combination with a two-illumination positions method: the shape is directly measured from the phase change between two source positions by means of a digital Fourier transform method. The TM shape data in conjunction with its displacement data renders a complete and accurate description of the TM deformation, a feature that no doubt will serve to better comprehend the hearing process. Acquiring knowledge from the tissue shape indicates a mechanical behavior and, indirectly, an alteration in the physiological structure due to middle ear diseases or damages in the tissue that can deteriorate sound transmission. The TM shape contour was successfully measured by using two source positions within DHI showing that the TM has a conical shape. Its maximum depth was found to be 2 mm, considering the umbo as the reference point with respect to the TM annulus plane, where the setup is arranged in such a manner that it is capable of measuring a height of up to 7 mm.
Collapse
|
9
|
Abstract
HYPOTHESIS The sound-induced motion of the tympanic membrane has features that are most consistent with modal responses to a uniform stimulus. BACKGROUND Conceptual models of the coupling of tympanic membrane motion to the ossicular chain can be classified as either modal responses to a uniform stimulation of the entire membrane or traveling wave models in which sound energy is captured at the membrane's rim and travels along the surface to the umbo. The stroboscopic holography technique we use can separate strongly modal or traveling wave-dominated motions of the tympanic membrane surface. METHODS We use computer-aided optoelectronic holography with stroboscopic illumination to measure the magnitude and phase of the sound-induced motion of more than 40,000 points on the surface of the tympanic membrane in cadaveric human temporal bones. Our techniques are sensitive to motions of the membrane as small as 0.01 µm and allow determinations of membrane displacement at frequencies as large as 20 kHz. RESULTS We report clear signs of both modal tympanic membrane responses and traveling waves on the human tympanic membrane. Modal responses are seen throughout the frequency range, whereas the traveling waves are most apparent between 2 and 8 kHz. In general, the magnitudes of the traveling waves are small compared with the modal magnitudes. CONCLUSION Much of the motion of the tympanic membrane is well approximated by modal motions of the tympanic membrane surface. This conclusion has implications for eardrum pathology and its treatment.
Collapse
|
10
|
Solís SM, Santoyo FM, Hernández-Montes MDS. 3D displacement measurements of the tympanic membrane with digital holographic interferometry. OPTICS EXPRESS 2012; 20:5613-5621. [PMID: 22418368 DOI: 10.1364/oe.20.005613] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A digital holographic interferometry (DHI) system with three object-illumination beams is used for the first time to measure micro-deformations along the x, y and z axes (3D) on the tympanic membrane (TM) surface of a post-mortem cat. In order to completely and accurately measure the TM surface displacements its shape is required to map on it the x, y and z micro-deformations. The surface contour is obtained by applying small shifts to the object illumination source position. A cw laser in stroboscopic mode and a CCD camera were used and synchronized to the acoustic excitation wave that produces a resonant vibration mode on the tympanic membrane surface. This research work reports on the 3D full field of view response of the TM to sound pressure, and has as its main goal the presentation of DHI as an alternative technique to study the TM real displacement behavior when subjected to sound waves, so it can be used as a diagnostic tool to prevent and treat TM diseases.
Collapse
Affiliation(s)
- S Muñoz Solís
- Centro de Investigaciones en Óptica, A.C., Loma del Bosque 115, León, Guanajuato, 37150, Mexico.
| | | | | |
Collapse
|
11
|
Flores-Moreno JM, Furlong C, Rosowski JJ, Harrington E, Cheng JT, Scarpino C, Santoyo FM. Holographic otoscope for nanodisplacement measurements of surfaces under dynamic excitation. SCANNING 2011. [PMID: 21898459 DOI: 10.1002/sca.v33.5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
We describe a novel holographic otoscope system for measuring nanodisplacements of objects subjected to dynamic excitation. Such measurements are necessary to quantify the mechanical deformation of surfaces in mechanics, acoustics, electronics, biology, and many other fields. In particular, we are interested in measuring the sound-induced motion of biological samples, such as an eardrum. Our holographic otoscope system consists of laser illumination delivery (IS), optical head (OH), and image processing computer (IP) systems. The IS delivers the object beam (OB) and the reference beam (RB) to the OH. The backscattered light coming from the object illuminated by the OB interferes with the RB at the camera sensor plane to be digitally recorded as a hologram. The hologram is processed by the IP using the Fresnel numerical reconstruction algorithm, where the focal plane can be selected freely. Our holographic otoscope system is currently deployed in a clinic, and is packaged in a custom design. It is mounted in a mechatronic positioning system to increase its maneuverability degrees to be conveniently positioned in front of the object to be measured. We present representative results highlighting the versatility of our system to measure deformations of complex elastic surfaces in the wavelength scale including a copper foil membrane and postmortem tympanic membrane. SCANNING 33: 342-352, 2011. © 2011 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- J M Flores-Moreno
- Center for Holographic Studies and Laser micro-mechaTronics, WPI, Worcester, MA 01609, USA.
| | | | | | | | | | | | | |
Collapse
|
12
|
Flores-Moreno JM, Furlong C, Rosowski JJ, Harrington E, Cheng JT, Scarpino C, Santoyo FM. Holographic otoscope for nanodisplacement measurements of surfaces under dynamic excitation. SCANNING 2011; 33:342-52. [PMID: 21898459 PMCID: PMC3193549 DOI: 10.1002/sca.20283] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2011] [Accepted: 08/02/2011] [Indexed: 05/12/2023]
Abstract
We describe a novel holographic otoscope system for measuring nanodisplacements of objects subjected to dynamic excitation. Such measurements are necessary to quantify the mechanical deformation of surfaces in mechanics, acoustics, electronics, biology, and many other fields. In particular, we are interested in measuring the sound-induced motion of biological samples, such as an eardrum. Our holographic otoscope system consists of laser illumination delivery (IS), optical head (OH), and image processing computer (IP) systems. The IS delivers the object beam (OB) and the reference beam (RB) to the OH. The backscattered light coming from the object illuminated by the OB interferes with the RB at the camera sensor plane to be digitally recorded as a hologram. The hologram is processed by the IP using the Fresnel numerical reconstruction algorithm, where the focal plane can be selected freely. Our holographic otoscope system is currently deployed in a clinic, and is packaged in a custom design. It is mounted in a mechatronic positioning system to increase its maneuverability degrees to be conveniently positioned in front of the object to be measured. We present representative results highlighting the versatility of our system to measure deformations of complex elastic surfaces in the wavelength scale including a copper foil membrane and postmortem tympanic membrane. SCANNING 33: 342-352, 2011. © 2011 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- J M Flores-Moreno
- Center for Holographic Studies and Laser micro-mechaTronics, WPI, Worcester, MA 01609, USA.
| | | | | | | | | | | | | |
Collapse
|
13
|
Biomechanics of the tympanic membrane. J Biomech 2011; 44:1219-36. [PMID: 21376326 DOI: 10.1016/j.jbiomech.2010.12.023] [Citation(s) in RCA: 94] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2010] [Revised: 12/13/2010] [Accepted: 12/17/2010] [Indexed: 11/23/2022]
|
14
|
Middle ear mechanics of cartilage tympanoplasty evaluated by laser holography and vibrometry. Otol Neurotol 2010; 30:1209-14. [PMID: 19779389 DOI: 10.1097/mao.0b013e3181bc398e] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
GOALS To assess the effects of thickness and position of cartilage used to reconstruct the tympanic membrane (TM) using a novel technique, time-averaged laser holography. BACKGROUND Cartilage is commonly used in TM reconstruction to prevent formation of retraction pockets. The thickness, position, and shape of the cartilage graft may adversely affect TM motion and hearing. We sought to systematically investigate these parameters in an experimental setting. METHODS Computer-assisted optoelectronic laser holography was used in 4 human cadaveric temporal bones to study sound-induced TM motion for 500 Hz to 8 kHz. Stapes velocity was measured with a laser Doppler vibrometer. Baseline (control) measurements were made with the TM intact. Measurements were repeated after a 0.5- or 1.0-mm-thick oval piece of conchal cartilage was placed on the medial TM surface in the posterior-superior quadrant. The cartilage was rotated so that it was either in contact with the bony tympanic rim and manubrium or not. RESULTS At frequencies less than 4 kHz, the cartilage graft had only minor effects on the overall TM fringe patterns. The different conditions had no effects on stapes velocity. Greater than 4 kHz, TM motion was reduced over the grafted TM, both with 0.5- and 1.0-mm-thick grafts. No significant differences in stapes velocity were seen with the 2 different thicknesses of cartilage compared with control. CONCLUSION Computer-assisted optoelectronic laser holography is a promising technique to investigate middle ear mechanics after tympanoplasty. Such positioning may prevent postoperative TM retraction. These findings and conclusions apply to cartilage placed in the posterior-superior TM quadrant.
Collapse
|
15
|
Cheng JT, Aarnisalo AA, Harrington E, Hernandez-Montes MDS, Furlong C, Merchant SN, Rosowski JJ. Motion of the surface of the human tympanic membrane measured with stroboscopic holography. Hear Res 2009; 263:66-77. [PMID: 20034549 DOI: 10.1016/j.heares.2009.12.024] [Citation(s) in RCA: 91] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Revised: 12/15/2009] [Accepted: 12/16/2009] [Indexed: 11/19/2022]
Abstract
Sound-induced motion of the surface of the human tympanic membrane (TM) was studied by stroboscopic holographic interferometery, which measures the amplitude and phase of the displacement at each of about 40,000 points on the surface of the TM. Measurements were made with tonal stimuli of 0.5, 1, 4 and 8 kHz. The magnitude and phase of the sinusoidal displacement of the TM at each driven frequency were derived from the fundamental Fourier component of the raw displacement data computed from stroboscopic holograms of the TM recorded at eight stimulus phases. The correlation between the Fourier estimates and measured motion data was generally above 0.9 over the entire TM surface. We used three data presentations: (i) plots of the phasic displacements along a single chord across the surface of the TM, (ii) phasic surface maps of the displacement of the entire TM surface, and (iii) plots of the Fourier derived amplitude and phase-angle of the surface displacement along four diameter lines that define and bisect each of the four quadrants of the TM. These displays led to some common conclusions: at 0.5 and 1kHz, the entire TM moved roughly in-phase with some small phase delay apparent between local areas of maximal displacement in the posterior half of the TM. At 4 and 8 kHz, the motion of the TM became more complicated with multiple local displacement maxima arranged in rings around the manubrium. The displacements at most of these maxima were roughly in-phase, while some moved out-of-phase. Superposed on this in- and out-of-phase behavior were significant cyclic variations in-phase with location of less than 0.2 cycles or occasionally rapid half-cycle step-like changes in-phase. The high frequency displacement amplitude and phase maps discovered in this study can not be explained by any single wave motion, but are consistent with a combination of low and higher order modal motions plus some small traveling-wave-like components. The observations of the dynamics of TM surface motion from this study will help us better understand the sound-receiving function of the TM and how it couples sound to the ossicular chain and inner ear.
Collapse
Affiliation(s)
- Jeffrey Tao Cheng
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA 02114, USA.
| | | | | | | | | | | | | |
Collapse
|
16
|
Aarnisalo AA, Cheng JT, Ravicz ME, Furlong C, Merchant SN, Rosowski JJ. Motion of the tympanic membrane after cartilage tympanoplasty determined by stroboscopic holography. Hear Res 2009; 263:78-84. [PMID: 19909803 DOI: 10.1016/j.heares.2009.11.005] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2009] [Revised: 10/29/2009] [Accepted: 11/05/2009] [Indexed: 10/20/2022]
Abstract
Stroboscopic holography was used to quantify dynamic deformations of the tympanic membrane (TM) of the entire surface of the TM before and after cartilage tympanoplasty of the posterior or posterior-superior part of the TM. Cartilage is widely used in tympanoplasties to provide mechanical stability for the TM. Three human cadaveric temporal bones were used. A 6 mm x 3 mm oval cartilage graft was placed through the widely opened facial recess onto the medial surface of the posterior or posterior-superior part of the TM. The graft was either in contact with the bony tympanic rim and manubrium or not. Graft thickness was either 0.5 or 1.0mm. Stroboscopic holography produced displacement amplitude and phase maps of the TM surface in response to stimulus sound. Sound stimuli were 0.5, 1, 4 and 7 (or 8)kHz tones. Middle-ear impedance was measured from the motion of the entire TM. Cartilage placement generally produced reductions in the motion of the TM apposed to the cartilage, especially at 4 kHz and 7 or 8 kHz. Some parts of the TM showed altered motion compared to the control in all three cases. In general, middle-ear impedance was either unchanged or increased somewhat after cartilage reconstruction both at low (0.5 and 1 kHz) and high (4 and 7 kHz) frequencies. At 4 kHz, with the 1.0mm thick graft that was in contact with the bony tympanic rim, the impedance slightly decreased. While our earlier work with time-averaged holography allowed us to observe differences in the pattern of TM motion caused by application of cartilage to the TM, stroboscopic holography is more sensitive to TM motions and allowed us to quantify the magnitude and phase of motion of each point on the TM surface. Nonetheless, our results are similar to those of our earlier work: The placement of cartilage on the medial surface of TM reduces the motion of the TM that apposes the cartilage. These obvious local changes occur even though the cartilage had little effect on the sound-induced motion of the stapes.
Collapse
Affiliation(s)
- Antti A Aarnisalo
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA, USA.
| | | | | | | | | | | |
Collapse
|
17
|
Rosowski JJ, Cheng JT, Ravicz ME, Hulli N, Hernandez-Montes M, Harrington E, Furlong C. Computer-assisted time-averaged holograms of the motion of the surface of the mammalian tympanic membrane with sound stimuli of 0.4-25 kHz. Hear Res 2009; 253:83-96. [PMID: 19328841 PMCID: PMC2711632 DOI: 10.1016/j.heares.2009.03.010] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2009] [Revised: 03/12/2009] [Accepted: 03/18/2009] [Indexed: 11/17/2022]
Abstract
Time-averaged holograms describing the sound-induced motion of the tympanic membrane (TM) in cadaveric preparations from three mammalian species and one live ear were measured using opto-electronic holography. This technique allows rapid measurements of the magnitude of motion of the tympanic membrane surface at frequencies as high as 25 kHz. The holograms measured in response to low and middle-frequency sound stimuli are similar to previously reported time-averaged holograms. However, at higher frequencies (f>4 kHz), our holograms reveal unique TM surface displacement patterns that consist of highly-ordered arrangements of multiple local displacement magnitude maxima, each of which is surrounded by nodal areas of low displacement magnitude. These patterns are similar to modal patterns (two-dimensional standing waves) produced by either the interaction of surface waves traveling in multiple directions or the uniform stimulation of modes of motion that are determined by the structural properties and boundary conditions of the TM. From the ratio of the displacement magnitude peaks to nodal valleys in these apparent surface waves, we estimate a Standing Wave Ratio of at least 4 that is consistent with energy reflection coefficients at the TM boundaries of at least 0.35. It is also consistent with small losses within the uniformly stimulated modal surface waves. We also estimate possible TM surface wave speeds that vary with frequency and species from 20 to 65 m/s, consistent with other estimates in the literature. The presence of standing wave or modal phenomena has previously been intuited from measurements of TM function, but is ignored in some models of tympanic membrane function. Whether these standing waves result either from the interactions of multiple surface waves that travel along the membrane, or by uniformly excited modal displacement patterns of the entire TM surface is still to be determined.
Collapse
Affiliation(s)
- John J Rosowski
- Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, MA 02114, USA.
| | | | | | | | | | | | | |
Collapse
|
18
|
Del Socorro Hernández-Montes M, Furlong C, Rosowski JJ, Hulli N, Harrington E, Cheng JT, Ravicz ME, Santoyo FM. Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranes. JOURNAL OF BIOMEDICAL OPTICS 2009; 14:034023. [PMID: 19566316 PMCID: PMC2718319 DOI: 10.1117/1.3153898] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Current methodologies for characterizing tympanic membrane (TM) motion are usually limited to either average acoustic estimates (admittance or reflectance) or single-point mobility measurements, neither of which suffices to characterize the detailed mechanical response of the TM to sound. Furthermore, while acoustic and single-point measurements may aid in diagnosing some middle-ear disorders, they are not always useful. Measurements of the motion of the entire TM surface can provide more information than these other techniques and may be superior for diagnosing pathology. We present advances in our development of a new compact optoelectronic holographic otoscope (OEHO) system for full field-of-view characterization of nanometer-scale sound-induced displacements of the TM surface at video rates. The OEHO system consists of a fiber optic subsystem, a compact otoscope head, and a high-speed image processing computer with advanced software for recording and processing holographic images coupled to a computer-controlled sound-stimulation and recording system. A prototype OEHO system is in use in a medical research environment to address basic science questions regarding TM function. The prototype provides real-time observation of sound-induced TM displacement patterns over a broad frequency range. Representative time-averaged and stroboscopic holographic interferometry results in animals and human cadaver samples are shown, and their potential utility is discussed.
Collapse
Affiliation(s)
- Maria Del Socorro Hernández-Montes
- Worcester Polytechnic Institute, Department of Mechanical Engineering and Center for Holographic Studies and Laser micro-mechaTronics, Worcester, Massachusetts 21202, USA.
| | | | | | | | | | | | | | | |
Collapse
|