• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4599785)   Today's Articles (3782)   Subscriber (49359)
For: Vigolo P, Fonzi F. An In Vitro Evaluation of Fit of Zirconium-Oxide-Based Ceramic Four-Unit Fixed Partial Dentures, Generated with Three Different CAD/CAM Systems, before and after Porcelain Firing Cycles and after Glaze Cycles. J Prosthodont 2008;17:621-6. [DOI: 10.1111/j.1532-849x.2008.00366.x] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
Number Cited by Other Article(s)
1
Chang MC, Cheng LW, Chuang SF, Chen YC. The influence of pontic distribution on the marginal and internal gaps of CAD/CAM five-unit anterior zirconia framework. J Dent Sci 2024;19:1105-1115. [PMID: 38618091 PMCID: PMC11010717 DOI: 10.1016/j.jds.2023.12.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/12/2023] [Indexed: 04/16/2024]  Open
2
Chokr H, Alshaarani F, Husein HA. Evaluation of the Marginal Fit of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) Zirconia Bridges Fabricated With Different Firing Cycles of Veneering Porcelain: An In Vitro Study. Cureus 2023;15:e34842. [PMID: 36923172 PMCID: PMC10010574 DOI: 10.7759/cureus.34842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/10/2023] [Indexed: 02/12/2023]  Open
3
Jánosi KM, Cerghizan D, Berneanu FD, Kovács A, Szász A, Mureșan I, Hănțoiu LG, Albu AI. Full-Mouth Rehabilitation of a Patient with Gummy Smile-Multidisciplinary Approach: Case Report. MEDICINA (KAUNAS, LITHUANIA) 2023;59:medicina59020197. [PMID: 36837400 PMCID: PMC9967420 DOI: 10.3390/medicina59020197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/05/2023] [Accepted: 01/16/2023] [Indexed: 01/20/2023]
4
Morsy N, El Kateb M, Azer A, Fathalla S. Fit of zirconia fixed partial dentures fabricated from conventional impressions and digital scans: A systematic review and meta-analysis. J Prosthet Dent 2021:S0022-3913(21)00496-0. [PMID: 34696907 DOI: 10.1016/j.prosdent.2021.08.025] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 08/20/2021] [Accepted: 08/23/2021] [Indexed: 10/20/2022]
5
Kitani J, Komine F, Kusaba K, Nakase D, Ito K, Matsumura H. Effect of firing procedures and layering thickness of porcelain on internal adaptation of zirconia cantilever resin-bonded fixed dental prostheses. J Prosthodont Res 2021;66:333-338. [PMID: 34544942 DOI: 10.2186/jpr.jpr_d_21_00055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
6
Lehmann KM, Weyhrauch M, Bjelopavlovic M, Scheller H, Staedt H, Ottl P, Kaemmerer PW, Wentaschek S. Marginal and Internal Precision of Zirconia Four-Unit Fixed Partial Denture Frameworks Produced Using Four Milling Systems. MATERIALS 2021;14:ma14102663. [PMID: 34069551 PMCID: PMC8161266 DOI: 10.3390/ma14102663] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/11/2021] [Revised: 05/12/2021] [Accepted: 05/13/2021] [Indexed: 11/23/2022]
7
Suzuki S, Ueda K, Erdelt K, Watanabe F, Güth JF. Effects of porcelain veneering methods on conformity of the marginal and internal fit of three-unit zirconia framework. Odontology 2021;109:719-728. [PMID: 33759088 DOI: 10.1007/s10266-021-00595-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 02/03/2021] [Indexed: 11/30/2022]
8
Alikhasi M, Ameri N, Siadat H, Shamshiri AR, Nejati M. Dimensional Changes of 3-Unit Implant-Supported Zirconia Frameworks of Two CAD/CAM Systems from Scanning to Sintering. Front Dent 2019;16:194-205. [PMID: 31858085 PMCID: PMC6911669 DOI: 10.18502/fid.v16i3.1591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2018] [Accepted: 11/03/2018] [Indexed: 11/26/2022]  Open
9
Bousnaki M, Chatziparaskeva M, Bakopoulou A, Pissiotis A, Koidis P. Variables affecting the fit of zirconia fixed partial dentures: A systematic review. J Prosthet Dent 2019;123:686-692.e8. [PMID: 31703922 DOI: 10.1016/j.prosdent.2019.06.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 06/02/2019] [Accepted: 06/03/2019] [Indexed: 10/25/2022]
10
Evaluation of marginal adaptation of Co-Cr-Mo metal crowns fabricated by traditional method and computer-aided technologies. J Dent Sci 2019;14:288-294. [PMID: 31528257 PMCID: PMC6742603 DOI: 10.1016/j.jds.2018.11.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Revised: 10/19/2018] [Indexed: 11/26/2022]  Open
11
TURKER B, KELES MA. In Vitro Gap Changes After Porcelain Firing Cycles of Three and Four Unit of CAD/CAM Milling, Laser Sintering and Cast Metal Ceramic Restorations. CLINICAL AND EXPERIMENTAL HEALTH SCIENCES 2019. [DOI: 10.33808/clinexphealthsci.565912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
12
Al Maaz A, Thompson GA, Drago C, An H, Berzins D. Effect of finish line design and metal alloy on the marginal and internal gaps of selective laser melting printed copings. J Prosthet Dent 2019;122:143-151. [PMID: 30948295 DOI: 10.1016/j.prosdent.2019.02.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Revised: 02/07/2019] [Accepted: 02/07/2019] [Indexed: 10/27/2022]
13
Izadi A, Vafaee F, Shishehian A, Roshanaei G, Fathi Afkari B. Evaluation of dimensional accuracy of dental bridges manufactured with conventional casting technique and CAD/CAM system with Ceramill Sintron blocks using CMM. J Dent Res Dent Clin Dent Prospects 2019;12:264-271. [PMID: 30774792 PMCID: PMC6368946 DOI: 10.15171/joddd.2018.041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Accepted: 11/19/2018] [Indexed: 11/09/2022]  Open
14
Yu H, Chen YH, Cheng H, Sawase T. Finish-line designs for ceramic crowns: A systematic review and meta-analysis. J Prosthet Dent 2019;122:22-30.e5. [PMID: 30782459 DOI: 10.1016/j.prosdent.2018.10.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 10/09/2018] [Accepted: 10/09/2018] [Indexed: 10/27/2022]
15
Micro-CT Analysis of Y-TZP Copings Made by Different CAD/CAM Systems: Marginal and Internal Fit. Int J Dent 2018;2018:5189767. [PMID: 30254675 PMCID: PMC6145157 DOI: 10.1155/2018/5189767] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2018] [Revised: 07/05/2018] [Accepted: 08/01/2018] [Indexed: 11/17/2022]  Open
16
Influence of Material Selection on the Marginal Accuracy of CAD/CAM-Fabricated Metal- and All-Ceramic Single Crown Copings. BIOMED RESEARCH INTERNATIONAL 2018;2018:2143906. [PMID: 29765979 PMCID: PMC5885340 DOI: 10.1155/2018/2143906] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Accepted: 02/14/2018] [Indexed: 11/23/2022]
17
Kim WK, Kim S. Effect of number of pontics and impression technique on the accuracy of four-unit monolithic zirconia fixed dental prostheses. J Prosthet Dent 2018. [PMID: 29526302 DOI: 10.1016/j.prosdent.2017.10.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
18
Daou EE, Ounsi H, Özcan M, Al-Haj Husain N, Salameh Z. Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography. J Prosthet Dent 2018;120:409-414. [PMID: 29724558 DOI: 10.1016/j.prosdent.2018.01.006] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2016] [Revised: 01/09/2018] [Accepted: 01/09/2018] [Indexed: 10/17/2022]
19
Pilo R, Folkman M, Arieli A, Levartovsky S. Marginal Fit and Retention Strength of Zirconia Crowns Cemented by Self-adhesive Resin Cements. Oper Dent 2018;43:151-161. [PMID: 29394141 DOI: 10.2341/16-367-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
20
Yun MJ, Jeon YC, Jeong CM, Huh JB. Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques. J Adv Prosthodont 2017;9:1-13. [PMID: 28243386 PMCID: PMC5321583 DOI: 10.4047/jap.2017.9.1.1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 11/09/2016] [Accepted: 12/20/2016] [Indexed: 11/08/2022]  Open
21
Ates SM, Yesil Duymus Z, Caglar I, Hologlu B. The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings. Clin Oral Investig 2017;21:2553-2560. [PMID: 28091875 DOI: 10.1007/s00784-017-2054-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Accepted: 01/09/2017] [Indexed: 10/20/2022]
22
Kale E, Seker E, Yilmaz B, Özcelik TB. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J Prosthet Dent 2016;116:890-895. [DOI: 10.1016/j.prosdent.2016.05.006] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Revised: 05/03/2016] [Accepted: 05/04/2016] [Indexed: 10/21/2022]
23
In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems. J Prosthet Dent 2016;117:762-766. [PMID: 27836145 DOI: 10.1016/j.prosdent.2016.09.011] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2016] [Revised: 09/24/2016] [Accepted: 09/26/2016] [Indexed: 11/21/2022]
24
Kocaağaoğlu H, Kılınç Hİ, Albayrak H, Kara M. In vitro evaluation of marginal, axial, and occlusal discrepancies in metal ceramic restorations produced with new technologies. J Prosthet Dent 2016;116:368-74. [DOI: 10.1016/j.prosdent.2016.03.013] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Revised: 03/17/2016] [Accepted: 03/18/2016] [Indexed: 10/21/2022]
25
Oka Y, Sasaki JI, Wakabayashi K, Nakano Y, Okamura SY, Nakamura T, Imazato S, Yatani H. Fabrication of a radiopaque fit-testing material to evaluate the three-dimensional accuracy of dental prostheses. Dent Mater 2016;32:921-8. [PMID: 27063458 DOI: 10.1016/j.dental.2016.03.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2015] [Revised: 09/09/2015] [Accepted: 03/22/2016] [Indexed: 10/22/2022]
26
Ates SM, Yesil Duymus Z. Influence of Tooth Preparation Design on Fitting Accuracy of CAD-CAM Based Restorations. J ESTHET RESTOR DENT 2016;28:238-46. [PMID: 27061751 DOI: 10.1111/jerd.12208] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
27
Schneebeli E, Brägger U, Scherrer SS, Keller A, Wittneben JG, Hicklin SP. Quality Evaluation of Zirconium Dioxide Frameworks Produced in Five Dental Laboratories from Different Countries. J Prosthodont 2015;26:399-409. [DOI: 10.1111/jopr.12391] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/07/2015] [Indexed: 11/26/2022]  Open
28
Comparison of Conventional Methods and Laser-Assisted Rapid Prototyping for Manufacturing Fixed Dental Prostheses: An In Vitro Study. BIOMED RESEARCH INTERNATIONAL 2015;2015:318097. [PMID: 26576419 PMCID: PMC4631850 DOI: 10.1155/2015/318097] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2014] [Accepted: 01/21/2015] [Indexed: 11/17/2022]
29
Effects of Computer-Aided Manufacturing Technology on Precision of Clinical Metal-Free Restorations. BIOMED RESEARCH INTERNATIONAL 2015;2015:619027. [PMID: 26557681 PMCID: PMC4628743 DOI: 10.1155/2015/619027] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Accepted: 08/12/2015] [Indexed: 11/17/2022]
30
Vigolo P, Mutinelli S, Biscaro L, Stellini E. An In Vivo Evaluation of the Fit of Zirconium-Oxide Based, Ceramic Single Crowns with Vertical and Horizontal Finish Line Preparations. J Prosthodont 2015;24:603-9. [DOI: 10.1111/jopr.12340] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/20/2015] [Indexed: 11/29/2022]  Open
31
Bayramoğlu E, Kulak Özkan Y, Yildiz C. Comparison of marginal and internal fit of press-on-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study. J Prosthet Dent 2015;114:52-8. [DOI: 10.1016/j.prosdent.2015.01.002] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 01/12/2015] [Accepted: 01/14/2015] [Indexed: 11/29/2022]
32
El-Dessouky R, Salama M, Shakal M, Korsel A. Marginal adaptation of CAD/CAM zirconia-based crown during fabrication steps. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.tdj.2014.12.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
33
Chellan P, Sadler PJ. The elements of life and medicines. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2015;373:20140182. [PMID: 25666066 PMCID: PMC4342972 DOI: 10.1098/rsta.2014.0182] [Citation(s) in RCA: 111] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
34
Demir N, Ozturk AN, Malkoc MA. Evaluation of the marginal fit of full ceramic crowns by the microcomputed tomography (micro-CT) technique. Eur J Dent 2014;8:437-444. [PMID: 25512721 PMCID: PMC4253096 DOI: 10.4103/1305-7456.143612] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
35
Lins L, Bemfica V, Queiroz C, Canabarro A. In vitro evaluation of the internal and marginal misfit of CAD/CAM zirconia copings. J Prosthet Dent 2014;113:205-11. [PMID: 25453562 DOI: 10.1016/j.prosdent.2014.09.010] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2014] [Revised: 09/15/2014] [Accepted: 09/15/2014] [Indexed: 11/30/2022]
36
Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies. J Prosthet Dent 2014;112:1432-6. [DOI: 10.1016/j.prosdent.2014.07.002] [Citation(s) in RCA: 85] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2014] [Revised: 07/04/2014] [Accepted: 07/09/2014] [Indexed: 12/14/2022]
37
Nam J, Tokutomi H. Using zirconia-based prosthesis in a complete-mouth reconstruction treatment for worn dentition with the altered vertical dimension of occlusion. J Prosthet Dent 2014;113:81-5. [PMID: 25438749 DOI: 10.1016/j.prosdent.2014.08.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2014] [Revised: 07/15/2014] [Accepted: 08/19/2014] [Indexed: 11/18/2022]
38
Varol S, Kulak-Özkan Y. In Vitro Comparison of Marginal and Internal Fit of Press-on-Metal Ceramic (PoM) Restorations with Zirconium-Supported and Conventional Metal Ceramic Fixed Partial Dentures Before and After Veneering. J Prosthodont 2014;24:387-93. [PMID: 25274041 DOI: 10.1111/jopr.12229] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/30/2014] [Indexed: 11/28/2022]  Open
39
Kim KB, Kim JH, Kim WC, Kim JH. In vitro evaluation of marginal and internal adaptation of three-unit fixed dental prostheses produced by stereolithography. Dent Mater J 2014;33:504-9. [PMID: 25087659 DOI: 10.4012/dmj.2014-017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
40
Bugurman BB, Turker SB. Clinical gap changes after porcelain firing cycles of zirconia fixed dentures. J Adv Prosthodont 2014;6:177-84. [PMID: 25006381 PMCID: PMC4085241 DOI: 10.4047/jap.2014.6.3.177] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 02/13/2014] [Accepted: 03/05/2014] [Indexed: 11/19/2022]  Open
41
Boitelle P, Mawussi B, Tapie L, Fromentin O. A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 2014;41:853-74. [DOI: 10.1111/joor.12205] [Citation(s) in RCA: 138] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2014] [Indexed: 11/27/2022]
42
MIURA S, INAGAKI R, KASAHARA S, YODA M. Fit of zirconia all-ceramic crowns with different cervical margin designs, before and after porcelain firing and glazing. Dent Mater J 2014;33:484-9. [DOI: 10.4012/dmj.2013-284] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
43
Raigrodski AJ, Yu A, Chiche GJ, Hochstedler JL, Mancl LA, Mohamed SE. Clinical efficacy of veneered zirconium dioxide-based posterior partial fixed dental prostheses: five-year results. J Prosthet Dent 2013;108:214-22. [PMID: 23031727 DOI: 10.1016/s0022-3913(12)60165-6] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
44
Yucel MT, Aykent F, Avunduk MC. In vitro evaluation of the marginal fit of different all-ceramic crowns. J Dent Sci 2013. [DOI: 10.1016/j.jds.2012.05.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]  Open
45
Song TJ, Kwon TK, Yang JH, Han JS, Lee JB, Kim SH, Yeo IS. Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems. J Adv Prosthodont 2013;5:219-25. [PMID: 24049561 PMCID: PMC3774934 DOI: 10.4047/jap.2013.5.3.219] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2012] [Revised: 05/06/2013] [Accepted: 06/13/2013] [Indexed: 12/02/2022]  Open
46
Kim KB, Kim JH, Kim WC, Kim HY, Kim JH. Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques. J Adv Prosthodont 2013;5:179-86. [PMID: 23755345 PMCID: PMC3675292 DOI: 10.4047/jap.2013.5.2.179] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2012] [Revised: 04/26/2013] [Accepted: 05/07/2013] [Indexed: 11/12/2022]  Open
47
Kim KB, Kim WC, Kim HY, Kim JH. An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system. Dent Mater 2013;29:e91-6. [PMID: 23680302 DOI: 10.1016/j.dental.2013.04.007] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2012] [Revised: 10/19/2012] [Accepted: 04/19/2013] [Indexed: 10/26/2022]
48
Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Ozcan M, Lassila LV. Effect of Surface Modification on the Bond Strength between Zirconia and Resin Cement. J Prosthodont 2013;22:529-536. [DOI: 10.1111/jopr.12030] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/27/2012] [Indexed: 11/27/2022]  Open
49
Nawafleh NA, Mack F, Evans J, Mackay J, Hatamleh MM. Accuracy and Reliability of Methods to Measure Marginal Adaptation of Crowns and FDPs: A Literature Review. J Prosthodont 2013;22:419-28. [DOI: 10.1111/jopr.12006] [Citation(s) in RCA: 151] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/08/2012] [Indexed: 11/30/2022]  Open
50
Takaba M, Tanaka S, Ishiura Y, Baba K. Implant-supported fixed dental prostheses with CAD/CAM-fabricated porcelain crown and zirconia-based framework. J Prosthodont 2013;22:402-7. [PMID: 23289495 DOI: 10.1111/jopr.12001] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/20/2012] [Indexed: 11/28/2022]  Open
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA