Inappropriate Implantable Cardioverter-Defibrillator Therapy. Card Electrophysiol Clin 2009; 1:155-171. [PMID: 28770782 DOI: 10.1016/j.ccep.2009.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Although improvements in implantable cardioverter-defibrillator (ICD) therapy have taken place, many challenges do remain. Inappropriate delivery of therapy is a big problem that impacts the quality of life of ICD recipients. Although there is now a clear understanding that atrial arrhythmias are the main cause of inappropriate ICD therapies, physicians have not been very successful in preventing them. Additionally, although many tachycardia detection discriminators have been shown to be helpful, it is not clear that there is a particular combination that is ideal for all patients. Until such an algorithm is developed (which may not be possible), a detailed knowledge and use of all available programming options, guided by special characteristics of each unique patient, are the only foreseeable solutions. Finally, one must face the prospect that this problem cannot be vanquished, but only ameliorated.
Collapse
|
2
|
|
3
|
Klein GJ, Gillberg JM, Tang A, Inbar S, Sharma A, Unterberg-Buchwald C, Dorian P, Moore H, Duru F, Rooney E, Becker D, Schaaf K, Benditt D. Improving SVT Discrimination in Single-Chamber ICDs: A New Electrogram Morphology-Based Algorithm. J Cardiovasc Electrophysiol 2006; 17:1310-9. [PMID: 17096661 DOI: 10.1111/j.1540-8167.2006.00643.x] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Wide-spread adoption of ICD therapy has focused efforts on improving the quality of life for patients by reducing "inappropriate" shock therapies. To this end, distinguishing supraventricular tachycardia from ventricular tachycardia remains a major challenge for ICDs. More sophisticated discrimination algorithms based on ventricular electrogram morphology have been made practicable by the increased computational ability of modern ICDs. METHODS AND RESULTS We report results from a large prospective study (1,122 pts) of a new ventricular electrogram morphology tachycardia discrimination algorithm (Wavelet Dynamic Discrimination, Medtronic, Minneapolis, MN, USA) operating at minimal algorithm setting (RV coil-can electrogram, match threshold of 70%). This is a nonrandomized cohort study of ICD patients using the morphology discrimination of the Wavelet algorithm to distinguish SVT and VT/VF. The Wavelet criterion was required ON in all patients and all other supraventricular tachycardia discriminators were required to be OFF. Spontaneous episodes (N = 2,235) eligible for ICD therapy were adjudicated for detection algorithm performance. The generalized estimating equations method was used to remove bias introduced when an individual patient contributes multiple episodes. Inappropriate therapies for supraventricular tachycardia were reduced by 78% (90% CI: 72.8-82.9%) for episodes within the range of rates where Wavelet was programmed to discriminate. Sensitivity for sustained ventricular tachycardia was 98.6% (90% CI: 97-99.3%) without the use of high-rate time out. CONCLUSIONS Results from this prospective study of the Wavelet electrogram morphology discrimination algorithm operating as the sole discriminator in the ON mode demonstrate that inappropriate therapy for supraventricular tachycardia in a single-chamber ICD can be dramatically reduced compared to rate detection alone.
Collapse
|
4
|
Theuns DAMJ, Rivero-Ayerza M, Goedhart DM, van der Perk R, Jordaens LJ. Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators. Heart Rhythm 2006; 3:1332-8. [PMID: 17074640 DOI: 10.1016/j.hrthm.2006.06.034] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2006] [Accepted: 06/28/2006] [Indexed: 10/24/2022]
Abstract
BACKGROUND To reduce inappropriate therapy from implantable cardioverter-defibrillators (ICDs), electrogram morphology discrimination has been developed to improve arrhythmia discrimination without compromising device safety. OBJECTIVES The purpose of this study was to determine the accuracy of the morphology discrimination algorithm for detecting ventricular tachycardia (VT). METHODS Stored electrograms of 795 tachyarrhythmias from 106 patients with a St. Jude Medical ICD (51 single-chamber and 55 dual-chamber) were analyzed by the investigators. The data were analyzed for morphology discrimination alone, sudden onset and stability, and morphology discrimination in combination with sudden onset and stability. Data were corrected for multiple episodes within a patient with the generalized estimating equation method. RESULTS Using the nominal template match of 60%, morphology discrimination alone provided sensitivity and specificity of 78% and 95% for single-chamber ICDs and 63% and 92% for dual-chamber ICDs, respectively. Based on the receiver operator characteristic curve, the optimal-match percent threshold was 80% to 85% but at the expense of specificity. Morphology discrimination combined with sudden onset and stability increased sensitivity to 98% with specificity of 86% in single-chamber devices. In dual-chamber devices, the loss in sensitivity is compensated by rate branch analysis, yielding a sensitivity of 98%. CONCLUSION Arrhythmia discrimination based on electrogram morphology has the potential to reject atrial tachyarrhythmias. However, there is a risk for underdetection of ventricular tachyarrhythmias if arrhythmia discrimination is primarily based on morphology. To guarantee patient safety in single-chamber devices, the morphology discrimination algorithm must be programmed in combination with established detection algorithms. In dual-chamber devices, loss of sensitivity is compensated by the V > A rate branch.
Collapse
|
5
|
Compton SJ, Merrill JJ, Dorian P, Cao J, Zhou D, Gillberg JM. Continuous template collection and updating for electrogram morphology discrimination in implantable cardioverter defibrillators. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29:244-54. [PMID: 16606391 DOI: 10.1111/j.1540-8159.2006.00330.x] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Electrogram morphology analysis improves discrimination of supraventricular tachycardias (SVTs) from ventricular tachycardias (VTs) in implantable cardioverter defibrillators (ICDs), but electrogram morphology may change with lead maturation, drugs, or disease progression. We report the clinical performance of an automatic algorithm that creates and updates templates from non-paced, slow rhythm and continuously checks the quality of the template used for arrhythmia discrimination. METHODS AND RESULTS We studied this algorithm in 193 patients with single-chamber ICDs (Marquis VR, Medtronic Inc., Minneapolis, MN, USA). Of the 112 patients who completed 6-month follow-up, 99.1% of the patients had > or =1 automatic template created. Match scores between template and ongoing rhythm are computed using Haar Wavelets. Of the 435 automatic templates evaluated at follow-up, 423 (97.2%) had a median match score > or =70%. Intrinsic rhythm at 1 month had significantly higher match scores (P < 0.001) with automatic templates (90.3 +/- 7.0%) than with manual templates (85.7 +/- 10.9%) generated at pre-hospital discharge (PHD). The percentage of appropriately rejected SVTs was slightly higher with the automatic template (280/339 episodes) than with the manual template at PHD (272/339 episodes) while the Wavelet detection of VT was the same (218/220 episodes). CONCLUSIONS In patients receiving ICDs, the automatic templates were successfully created during a 6-month follow-up period, and consistently matched the patients' intrinsic rhythm at the nominal match threshold. Both early (<1 month postimplant) and late (1- to 3-month follow-up period) changes in electrogram morphology were identified, confirming the need for automatic template updating.
Collapse
|
6
|
Lüthje L, Vollmann D, Rosenfeld M, Unterberg-Buchwald C. Electrogram configuration and detection of supraventricular tachycardias by a morphology discrimination algorithm in single chamber ICDs. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 28:555-60. [PMID: 15955189 DOI: 10.1111/j.1540-8159.2005.50011.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Inappropriate ICD therapy for supraventricular tachycardia (SVT) remains a significant problem. A morphology-based algorithm (Wavelet) compares baseline and tachycardia electrograms (EGM). For this analysis different EGM sources can be programmed. This study evaluates the performance of Wavelet using two different EGM configurations (SVC-Can and RV-Can) for the detection of exercise-induced SVT. METHODS Patients with a Medtronic model 7230 single chamber ICD and a dual coil lead were included. For each EGM source (SVC-Can or RV-Can), a baseline EGM template was acquired and the morphology similarity to this template (match percentage) was evaluated for 10-15 beats at different heart rates during exercise testing. The lower VT detection limit was programmed to 600 ms (therapies off). RESULTS A total of 28 patients (66.9 +/- 4.7 years, 93% men) and 5,824 intracardiac QRS complexes were analyzed. With the RV-Can source, a consistently high similarity to the baseline EGM template was observed (< or =100 bpm: 90.90 +/- 0.56%; >100 bpm: 90.24 +/- 0.55%, P > 0.05). In contrast, SVC-Can was associated with a lower match percentage at baseline and a significant decrease at higher heart rates (< or =100 bpm: 77.91 +/- 2.65%; >100 bpm: 59.05 +/- 5.65%, P < 0.005). Accordingly, the specificity for appropriate detection of exercise-induced SVT was higher with RV-Can (21/21 episodes) than with SVC-Can (8/18 episodes, specificity 100% vs 44%; P < 0.0001). CONCLUSION The RV-Can configuration appears to be superior to SVC-Can as EGM source for appropriate SVT detection with the Wavelet algorithm.
Collapse
Affiliation(s)
- L Lüthje
- Kardiologie und Pneumologie, Georg-August-Universität Göttingen, Robert-Koch-Strasse 40, D-37099 Göttingen, Germany.
| | | | | | | |
Collapse
|
7
|
Saba S, Barrington W, Ganz LI. New method for real-time discrimination and management of ventricular and supraventricular tachyarrhythmias applicable to patients with dual-chamber cardioverter-defibrillators. Am J Cardiol 2004; 93:111-4. [PMID: 14697482 DOI: 10.1016/j.amjcard.2003.08.080] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
In this study we describe a highly sensitive and specific method for discriminating between ventricular and supraventricular tachyarrhythmias based on the response to simultaneous atrial and ventricular antitachycardia pacing. This new method, which can terminate supraventricular tachycardias in >50% of patients, can be easily implemented in a new generation of dual-chamber defibrillators.
Collapse
Affiliation(s)
- Samir Saba
- Electrophysiology Division, Cardiovascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania 15213, USA.
| | | | | |
Collapse
|
8
|
Rojo-Alvarez JL, Arenal-Maíz A, Artés-Rodríguez A. Discriminating between supraventricular and ventricular tachycardias from EGM onset analysis. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE : THE QUARTERLY MAGAZINE OF THE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY 2002; 21:16-26. [PMID: 11935984 DOI: 10.1109/51.993190] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
9
|
|
10
|
Rojo-Alvarez JL, Arenal-Maíz A, Artés-Rodríguez A. Support vector black-box interpretation in ventricular arrhythmia discrimination. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE : THE QUARTERLY MAGAZINE OF THE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY 2002; 21:27-35. [PMID: 11935985 DOI: 10.1109/51.993191] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
11
|
Abstract
Implantable cardioverter defibrillators (ICDs) have evolved from the treatment of last resort to the gold standard therapy for patients at high risk for ventricular tachyarrhythmias. High-risk patients include those who have survived life-threatening arrhythmias, and individuals with cardiac diseases who are at risk for such arrhythmias, but are symptomless. Use of an ICD will affect the patient's quality of life. Some drugs can substantially affect defibrillator function and efficacy, and possible drug-device interactions should be considered. Patients with ICDs may encounter cell phones, antitheft detectors, and many other sources of potential electromagnetic Interference. In addition to treating ventricular tachyarrhythmias, new defibrillators provide full featured dual chamber pacing, and could treat atrial arrhythmias, and congestive heart failure by means of biventricular pacing.
Collapse
Affiliation(s)
- M Glikson
- Heart Institute, Sheba Medical Centre, Tel Aviv University, Tel Hashomer, Israel
| | | |
Collapse
|
12
|
Duru F, Bauersfeld U, Rahn-Schönbeck M, Candinas R. Morphology discriminator feature for enhanced ventricular tachycardia discrimination in implantable cardioverter defibrillators. Pacing Clin Electrophysiol 2000; 23:1365-74. [PMID: 11025892 DOI: 10.1111/j.1540-8159.2000.tb00964.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The morphology discriminator (MD) feature is an electrogram template matching algorithm that intends to improve tachycardia discrimination in implantable cardioverter defibrillators (ICDs). The aim of this study was to evaluate the performance of this feature during spontaneously occurring ventricular and supraventricular tachyarrhythmias and exercise induced sinus tachycardia. Twenty-three patients (20 men, 3 women; mean age 54.3 +/- 13.8 years) with pectorally implanted Ventritex Contour MD, Angstrom MD, and Profile MD ICDs were studied. The stability of the acquired morphology template and performance of the algorithm during spontaneous tachyarrhythmias were evaluated at follow-up. A treadmill exercise test was performed in 16 patients along with continuous telemetric monitoring of matching scores. A satisfactory template could be acquired at baseline in 22 (96%) patients. Variations in electrogram morphology necessitated new template acquisition in seven (30%) patients at first follow-up (6-8 weeks postimplant). During a mean follow-up of 9.1 +/- 3.7 months, 56 ventricular tachycardia (VT) and 15 supraventricular tachycardia episodes (sinus tachycardia in two-thirds) in 11 patients were all appropriately discriminated by the MD feature. Exercise testing showed appropriate discrimination of sinus tachycardia in 15 (94%) of 16 patients. A common observation was postshock changes in electrogram morphology that resulted in transient mismatch with the template. In conclusion, the recently introduced MD feature in ICDs has a high sensitivity for detection of VT and high specificity for rejection of sinus tachycardia. Postshock changes in electrogram morphology have been observed that may cause inappropriate redetection. Marked variations of electrogram morphology over time may be a concern in some patients, especially during lead maturation.
Collapse
Affiliation(s)
- F Duru
- Cardiac Arrhythmia Unit, University Hospital of Zurich, Switzerland.
| | | | | | | |
Collapse
|
13
|
Abstract
The fifth generation of implantable cardioverter-defibrillators offer enhanced modes of detection of atrial and ventricular arrhythmias, antitachycardia pacing and shocks, multiprogrammability, intracardiac electrogram storage, and all functions of antibradycardia dual-chamber pacing including rate responsiveness and mode switching. There is no consensus on the indications for dual-chamber pacemaker defibrillator systems. This review focuses on the four major options of newer devices that might benefit patients: 1) permanent dual-chamber pacing in ischemic coronary disease patients, 2) detection and management of atrial fibrillation or other atrial tachyarrhythmias, 3) some newer indications for pacing, and 4) the suppression of inappropriate interventions. On the basis of published data, newer indications for the dual-chamber systems, advantages and limitations, and future perspectives are discussed.
Collapse
Affiliation(s)
- D Pfeiffer
- Department of Cardiology, Angiology and Hemostaseology, Division of Internal Medicine, University of Leipzig, Johannisallee 32, D-04103 Leipzig, Germany.
| | | | | |
Collapse
|
14
|
Sticherling C, Klingenheben T, Cameron D, Hohnloser SH. Worldwide clinical experience with a down-sized active can implantable cardioverter defibrillator in 162 consecutive patients. Worldwide 7221 ICD Investigators. Pacing Clin Electrophysiol 1998; 21:1778-83. [PMID: 9744442 DOI: 10.1111/j.1540-8159.1998.tb00278.x] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Treatment with an ICD is the first-line treatment for survivors of sudden cardiac death. More recently, evidence accumulates that prophylactic ICD therapy may be beneficial for selected subgroups of patients after myocardial infarction. Particularly for future studies on the value of prophylactic ICD therapy, downsized devices are needed to allow easy pectoral implantation with a single lead configuration and featuring extended memory capabilities. Accordingly, this study assesses the clinical performance of a downsized fourth-generation ICD in 162 consecutive patients. All devices could be successfully implanted pectorally, in 96% with a single lead configuration with a low defibrillation threshold of 10.6 +/- 5.2 J. During a 3-month follow-up, 26% of the patients received ICD therapy. Twenty percent had appropriate therapy for ventricular fibrillation (n = 9) and VT (n = 23), which was effective in all cases. Of the 450 episodes of VT, 426 were terminated by antitachycardia pacing. Fourteen patients (9%) had inappropriate ICD therapy mainly due to atrial fibrillation or sinus tachycardia, which could be reliably diagnosed by the ICD stored intracardiac electrograms.
Collapse
Affiliation(s)
- C Sticherling
- Department of Medicine, J.W. Goethe University Frankfurt, Germany
| | | | | | | |
Collapse
|