1
|
Chudzik M, Klimczak A, Wranicz JK. Ambulatory Holter monitoring in asymptomatic patients with DDD pacemakers - do we need ACC/AHA Guidelines revision? Arch Med Sci 2013; 9:815-20. [PMID: 24273562 PMCID: PMC3832827 DOI: 10.5114/aoms.2013.38675] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2011] [Revised: 05/16/2011] [Accepted: 06/19/2011] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION We sought to determine the usefulness of ambulatory 24-hour Holter monitoring in detecting asymptomatic pacemaker (PM) malfunction episodes in patients with dual-chamber pacemakers whose pacing and sensing parameters were proper, as seen in routine post-implantation follow-ups. MATERIAL AND METHODS Ambulatory 24-hour Holter recordings (HM) were performed in 100 patients with DDD pacemakers 1 day after the implantation. Only asymptomatic patients with proper pacing and sensing parameters (assessed on PM telemetry on the first day post-implantation) were enrolled in the study. The following parameters were assessed: failure to pace, failure to sense (both oversensing and undersensing episodes) as well as the percentage of all PM disturbances. RESULTS Despite proper sensing and pacing parameters, HM revealed PM disturbances in 23 patients out of 100 (23%). Atrial undersensing episodes were found in 12 patients (p < 0.005) with totally 963 episodes and failure to capture in 1 patient (1%). T wave oversensing was the most common ventricular channel disorder (1316 episodes in 9 patients, p < 0.0005). Malfunction episodes occurred sporadically, leading to pauses of up to 1.6 s or temporary bradycardia, which were, nevertheless, not accompanied by clinical symptoms. No ventricular pacing disturbances were found. CONCLUSIONS Asymptomatic pacemaker dysfunction may be observed in nearly 25% of patients with proper DDD parameters after implantation. Thus, ambulatory HM during the early post-implantation period may be a useful tool to detect the need to reprogram PM parameters.
Collapse
Affiliation(s)
- Michal Chudzik
- Department of Electrocardiology, Medical University of Lodz, Poland
| | | | | |
Collapse
|
2
|
Factors involved in correct analysis of intracardiac electrograms captured by Medtronic Inc. pacemakers during tachycardias. J Arrhythm 2013. [DOI: 10.1016/j.joa.2012.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
3
|
Kolb C, Nölker G, Lennerz C, Jetter H, Semmler V, Pürner K, Gutleben KJ, Reents T, Lang K, Lotze U. Use of an atrial lead with very short tip-to-ring spacing avoids oversensing of far-field R-wave. PLoS One 2012; 7:e38277. [PMID: 22745661 PMCID: PMC3382193 DOI: 10.1371/journal.pone.0038277] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2011] [Accepted: 05/01/2012] [Indexed: 11/18/2022] Open
Abstract
Objective The AVOID-FFS (Avoidance of Far-Field R-wave Sensing) study aimed to investigate whether an atrial lead with a very short tip-to-ring spacing without optimization of pacemaker settings shows equally low incidence of far-field R-wave sensing (FFS) when compared to a conventional atrial lead in combination with optimization of the programming. Methods Patients receiving a dual chamber pacemaker were randomly assigned to receive an atrial lead with a tip-to-ring spacing of 1.1 mm or a lead with a conventional tip-to-ring spacing of 10 mm. Postventricular atrial blanking (PVAB) was programmed to the shortest possible value of 60 ms in the study group, and to an individually determined optimized value in the control group. Atrial sensing threshold was programmed to 0.3 mV in both groups. False positive mode switch caused by FFS was evaluated at one and three months post implantation. Results A total of 204 patients (121 male; age 73±10 years) were included in the study. False positive mode switch caused by FFS was detected in one (1%) patient of the study group and two (2%) patients of the control group (p = 0.62). Conclusion The use of an atrial electrode with a very short tip-to-ring spacing avoids inappropriate mode switch caused by FFS without the need for individual PVAB optimization. Trial Registration ClinicalTrials.gov NCT00512915
Collapse
Affiliation(s)
- Christof Kolb
- Deutsches Herzzentrum und 1. Medizinische Klinik rechts der Isar, Faculty of Medicine, Technische Universität München, Munich, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Jastrzebski M. Ventricular activation sequence during left ventricular pacing promotes QRS complex oversensing in the atrial channel. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2011; 34:1682-6. [PMID: 21954967 DOI: 10.1111/j.1540-8159.2011.03219.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND Left ventricular (LV)-only pacing has a significant effect on delay in depolarization of parts of the ventricles that are likely oversensed in the right atrial channel. The study aimed to assess the impact of ventricular activation sequence on QRS oversensing and far-field endless-loop pacemaker tachycardia (ELT) in patients who received cardiac resynchronization therapy (CRT) devices. METHODS The study examined 102 patients with CRT devices. Oversensing artifacts in the atrial channel were inspected on intracardiac electrograms, and their timing with respect to the beginning of QRS was determined during DDD-right ventricular (RV), DDD-LV, DDD-biventricular (BiV), and AAI pacing modes. The occurrence of ELT during DDD-LV pacing with a postventricular atrial refractory period (PVARP) of 250 ms was also assessed. RESULTS The timing of oversensing artifacts (in relation to the beginning of surface QRS) was dependent on ventricular activation sequence, occurring promptly following intrinsic activation via the right bundle branch (47.1 ± 26.4 ms), later during RV pacing (108.7 ± 22.5 ms) or BiV pacing (109.4 ± 23.1 ms), and significantly later, corresponding to the final part of the QRS, during LV pacing (209.6 ± 40.0 ms, range: 140-340 ms, P < 0.001). Oversensing was significantly more frequent during LV than during RV pacing (35.3% vs 22.5%, P < 0.001). Far-field ELT was observed in six patients. CONCLUSIONS Oversensing artifacts in the atrial channel are likely caused by depolarization of the basal part of the right ventricle. The novel mechanism of QRS oversensing outside PVARP, caused by a reversed ventricular activation sequence during LV-only pacing, may be important in some CRT patients.
Collapse
Affiliation(s)
- Marek Jastrzebski
- First Department of Cardiology and Hypertension, University Hospital, Cracow, Poland.
| |
Collapse
|
5
|
SILBERBAUER JOHN, ARYA ANITA, VEASEY RICKA, BOODHOO LANA, KAMALVAND KAYVAN, OâNUNAIN SEAN, HILDICK-SMITH DAVID, PAUL VINCE, PATEL NIKHILR, LLOYD GUYW, SULKE NEIL. The Effect of Bipole Tip-to-Ring Distance in Atrial Electrodes upon Atrial Tachyarrhythmia Sensing Capability in Modern Dual-Chamber Pacemakers. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2010; 33:85-93. [DOI: 10.1111/j.1540-8159.2009.02576.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Silberbauer J, Veasey RA, Freemantle N, Arya A, Boodhoo L, Sulke N. The relationship between high-frequency right ventricular pacing and paroxysmal atrial fibrillation burden. Europace 2009; 11:1456-61. [DOI: 10.1093/europace/eup218] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
7
|
Lewalter T, Tuininga Y, Fröhlig G, Remerie S, Eberhardt F, Schmidt J, van Groeningen C, Wohlgemuth P. Morphology-Enhanced Atrial Event Classification Improves Sensing in Pacemakers. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 30:1455-63. [PMID: 18070298 DOI: 10.1111/j.1540-8159.2007.00891.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
8
|
Silberbauer J, Sulke N. The role of pacing in rhythm control and management of atrial fibrillation. J Interv Card Electrophysiol 2007; 18:159-86. [PMID: 17473977 DOI: 10.1007/s10840-007-9087-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2006] [Accepted: 02/01/2007] [Indexed: 11/28/2022]
Abstract
Atrial fibrillation is the most common sustained cardiac arrhythmia and is increasing in prevalence with an ageing population. As the arrhythmia is often asymptomatic the true prevalence is likely even higher. Largely because of stroke this arrhythmia places a huge financial burden on the health economy. Despite this, large studies assessing rate versus rhythm control have been equivocal. Because of the ineffectiveness of pharmacological therapy much research effort has been undertaken in device and ablative approaches to rhythm management. Although catheter ablation has gained favour because of the high success rates the technique requires considerable expertise and still has a significant complication profile maintaining interest in pacing therapies for atrial fibrillation. Dual chamber versus single-chamber ventricular pacing has been shown to significantly reduce the incidence of atrial fibrillation. Research is currently underway to see if minimising the deleterious effects of right ventricular apical pacing could further increase the benefits of atrioventricular synchronous pacing. Several studies show some (albeit variable) reduction in AF burden with anti-AF algorithms in the setting of bradycardia. Antitachycardia pacing, on the other hand, has not been shown to treat AF in a randomised trial despite the successful termination of co-existent atrial tachycardias. There is increasing evidence that alternative atrial pacing sites may treat AF by improving atrial function. Furthermore, these strategies coupled with other therapies in a 'hybrid approach' have also showed promising results.
Collapse
Affiliation(s)
- John Silberbauer
- Eastbourne General Hospital East Sussex Hospitals NHS Trust, Eastbourne, BN21 2UD, UK
| | | |
Collapse
|
9
|
Eberhardt F, Schuchert A, Schmitz D, Zerm T, Mitzenheim S, Wiegand UK. Incidence and Significance of Far-Field R Wave Sensing in a VDD-Implantable Cardioverter Defibrillator. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 30:395-403. [PMID: 17367360 DOI: 10.1111/j.1540-8159.2007.00681.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND A VDD-implantable cardioverter-defibrillator (ICD) provides atrioventricular (AV) synchronous stimulation when necessary and incorporates the advantages of dual chamber arrhythmia discrimination algorithms both at potentially lower costs and less periprocedural complications than a DDD-ICD system. A prerequisite for correct dual chamber ICD function is reliable atrial sensing. METHODS We evaluated atrial near- and ventricular far-field sensing and its impact on the dual-chamber detection algorithm in 106 patients with a single-lead VDD-ICD during a 12-month follow-up period. RESULTS Six hundred and thirty-nine follow-ups were included. Mean near-field amplitude was 3.82 +/- 1.76 mV; mean far-field amplitude was 0.31 +/- 0.15 mV. 46% of patients had far-fields >0.35 mV and 35% of patients showed atrial EGM markers corresponding to a ventricular far-field in at least one follow-up. Six hundred and forty-five tachycardia episodes were evaluated. Due to far-field sensing, three of 66 episodes (4.5%) of sinus tachycardia were misclassified as ventricular tachycardia (VT), leading to antitachycardia therapies. Delayed detection of VT was seen in a 12 of 323 episodes (3.7%) in five of 62 patients (8%) having VT events (delay 6.4 +/- 6.0 seconds (range 2-24 seconds)). Stable far-field amplitudes <0.2 mV in a follow-up had a high negative predictive value for the occurrence of malfunction during tachycardia-conversely, high far-field amplitudes or a high incidence of far-field markers are only moderately correlated with malfunction. CONCLUSIONS Ventricular far-field sensing in a VDD-ICD is not uncommon, however, tachycardia detection by the dual chamber algorithm is not seriously impaired by far-field sensing.
Collapse
Affiliation(s)
- Frank Eberhardt
- Universitätsklinikum Schleswig Holstein Campus Luebeck, Medizinische Klinik II, Luebeck, Germany.
| | | | | | | | | | | |
Collapse
|
10
|
Van Gelder BM, Van Den Broek W, Bracke FA, Meijer A. Paradoxical Atrial Undersensing: Noise Rate Reversion or Amplifier Ringing? J Cardiovasc Electrophysiol 2006; 17:1371-4. [PMID: 16978248 DOI: 10.1111/j.1540-8167.2006.00597.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Atrial tachy-arrhythmias may give rise to mode switching or noise rate reversion in dual-chamber pacemakers. In case of high amplitude of the atrial electrogram during tachycardia, a paradoxical behavior of atrial sensitivity programming can be observed. Two patients with implanted dual-chamber pacemakers showed intermittent and complete loss of atrial sensing during atrial tachycardia during device programming to a higher atrial sensitivity setting. This phenomenon is caused by amplifier ringing and can be considered as a state of amplifier saturation, which disables atrial sensing in spite of the high amplitude of the atrial signal. In patients with high amplitude of the atrial electrogram during atrial tachycardia, a paradoxical behavior of sensitivity programming resulting in atrial undersensing can be observed.
Collapse
|
11
|
Kolb C, Wille B, Maurer D, Schuchert A, Weber R, Schibgilla V, Klein N, Hümmer A, Schmitt C, Zrenner B. Management of Far-Field R Wave Sensing for the Avoidance of Inappropriate Mode Switch in Dual Chamber Pacemakers: Results of the FFS-Test Study. J Cardiovasc Electrophysiol 2006; 17:992-7. [PMID: 16948743 DOI: 10.1111/j.1540-8167.2006.00545.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
BACKGROUND AND OBJECTIVE Far-field R wave sensing (FFS) in the atrial channel of dual chamber pacemakers is a relevant source for inappropriate mode switch from the DDD mode to the DDI or VDI mode. Inappropriate loss of atrioventricular synchrony due to false positive mode switch is hemodynamically disadvantageous, may induce atrial tachyarrhythmias, can lead to pacemaker syndrome, and impairs the reliability of pacemaker Holter data. The aim of the study was to determine whether individual adjustment of the postventricular atrial blanking period (PVAB) based on an additional test is effective in avoiding inappropriate mode switch due to FFS when compared with standard programming of the PVAB. METHODS A total of 207 patients were supplied with a St. Jude Medical Identity DR or Identity ADx DR dual chamber pacemaker for sinus nodal disease (n = 84), atrioventricular block (n = 79), binodal disease (n = 35), or other indications (n = 9). At hospital discharge, they were randomized to an individually optimized PVAB (n = 100) or to a control group with the PVAB left at the nominal of 100 msec (n = 107). Primary endpoint was the occurrence of inappropriate mode switch due to FFS within 3 months after pacemaker implantation assessed by stored electrograms of the pacemaker. RESULTS At the 3-month follow-up, 28/107 (26%) patients with the standard programming of the PVAB showed at least one episode of inappropriate mode switch due to FFS versus 10/100 (10%) patients with optimized PVAB (P < 0.01). The optimized PVAB was shorter than the nominal PVAB in about one-third of patients and longer in about two-third of patients. Different atrial lead localizations were not associated with the occurrence of inappropriate mode switch. CONCLUSIONS Individual adjustment of the PVAB significantly reduces the incidence of inappropriate mode switch due to FFS.
Collapse
Affiliation(s)
- Christof Kolb
- Deutsches Herzzentrum and 1. Med. Klinik rechts der Isar der TU München, Munich, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Israel CW, Neubauer H, Olbrich HG, Hartung W, Treusch S, Hohnloser SH. Incidence of Atrial Tachyarrhythmias in Pacemaker Patients: Results from the Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated Patients (BEATS) Study. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29:582-8. [PMID: 16784423 DOI: 10.1111/j.1540-8159.2006.00405.x] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVES The prospective Balanced Evaluation of Atrial Tachyarrhythmias in Stimulated patients (BEATS) study compared atrial tachyarrhythmia (AT) detection by means of serial ECG recordings versus device detection. BACKGROUND The annual incidence of AT in patients with dual-chamber pacemakers may be significantly underestimated based on ECG and Holter recordings. METHODS A DDD(R) device capable of AT-triggered dual-channel electrogram (EGM) storage was implanted in 254 patients (70 +/- 11 years, 159 men) with a class I pacing indication. Patients were seen at 6, 26, and 52 weeks after pacemaker implantation. At all visits, symptoms were checked, surface ECGs were recorded including a 24-hour Holter recording at 6 weeks, and the pacemakers were interrogated. Primary study endpoint was AT documentation by surface ECG/Holter versus stored EGMs. Secondary endpoints consisted of the association between patients' symptoms and AT documentation, and of the AT incidence depending on pacing indication and a history of AT. RESULTS ATs were documented by ECG/Holter recordings in 37 patients (15%) and by stored EGMs in 137 patients (54%) (P < 0.0001). Symptoms were absent in 108 of 137 patients (79%) with device-documented AT but present in 70 of 117 patients (60%) without AT documentation. AT documentation was more frequent in patients with a history of AT but not in patients with sinus node compared to AV node disease. CONCLUSION ATs occur in pacemaker patients significantly more frequently than estimated by ECG/Holter recordings. Only the analysis of device-stored EGMs allows reliable assessment of the AT burden.
Collapse
Affiliation(s)
- Carsten W Israel
- J. W. Goethe University, Department of Cardiology, Clinical Electrophysiology, Frankfurt, Germany
| | | | | | | | | | | |
Collapse
|
13
|
Eberhardt F, Bonnemeier H, Lipphardt M, Hofmann UG, Schunkert H, Wiegand UKH. Atrial near-field and ventricular far-field analysis by automated signal processing at rest and during exercise. Ann Noninvasive Electrocardiol 2006; 11:118-26. [PMID: 16630085 PMCID: PMC7479926 DOI: 10.1111/j.1542-474x.2006.00092.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Sophisticated monitoring of atrial activity is a prerequisite for modern pacemaker therapy. Ideally, near-fields and ventricular far-fields ought to be distinguished by beat-to-beat template analysis of the atrial signal. A prerequisite is that atrial signals are stable under different conditions. METHODS AND RESULTS A Matlab routine was developed to analyze atrial electrograms of 23 patients at least 3 months after implantation of a dual chamber pacemaker under several conditions including at rest, bipolar at rest, in an upright position, during treadmill exercise, and postexercise. A near-field and far-field template was created and amplitudes, widths, and slew rates were measured. In bipolar configuration, near-field amplitude at rest was 3.04 +/- 0.94 mV (unipolar)/3.36 +/- 1.0 mV (bipolar) versus 3.18 +/- 1.0 mV (bipolar) at peak exercise. Far-field amplitude at rest was 1.66 +/- 1.18 (unipolar)/0.47 +/- 0.27 mV (bipolar) and 0.41 +/- 0.21 mV (bipolar) at peak exercise (n.s. for bipolar measurements). No overall significant changes were observed for near- and far-field widths and slew rates during exercise. Shorter tip-ring distances of the atrial bipole, lead position, and the presence of sinus node disease did not have any impact on overall near- and far-field signal characteristics. Intraindividual differences between rest and peak exercise were moderate (range: near-field +0.15 to -0.54 mV; range: far-field +0.05 to -0.18 mV). CONCLUSIONS Atrial near and far fields can be automatically classified and quantified by automated signal processing. Signals did not change during exercise or change of posture. This is a prerequisite for the implementation of beat-to-beat template analysis into pacemakers.
Collapse
Affiliation(s)
- Frank Eberhardt
- University Hospital Schleswig Holstein, Campus Luebeck, Medicine II, Luebeck, Germany.
| | | | | | | | | | | |
Collapse
|
14
|
Kolb C, Halbfass P, Zrenner B, Schmitt C. Paradoxical Atrial Undersensing Due to Inappropriate Atrial Noise Reversion of Atrial Fibrillation in Dual-Chamber Pacemakers. J Cardiovasc Electrophysiol 2005; 16:696-700. [PMID: 16050825 DOI: 10.1111/j.1540-8167.2005.40762.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
UNLABELLED Paradoxical atrial undersensing. BACKGROUND Paradoxical atrial undersensing at high atrial sensing levels was described as false atrial noise reversion of dual-chamber pacemakers during atrial fibrillation in a sheep model. It is unknown whether this phenomenon occurs in humans. METHODS In total, 71 patients with implanted dual-chamber pacemakers and atrial fibrillation were tested for the occurrence of paradoxical atrial undersensing. After determination of the sensing threshold of atrial fibrillation (30 seconds of continuous mode switch), the atrial sensing level was stepwise increased. If, after correct mode switch behavior at insensitive levels, loss of mode switch occurred at higher sensing levels and if the pacing mode was consistent with atrial noise reversion, paradoxical atrial undersensing was assumed. RESULTS Paradoxical atrial undersensing could be provoked in 9 of 71 (13%) patients at a median sensing level of 0.4 (range 0.15-2.0) mV. Six different pacemaker models of five different manufacturers were affected. The occurrence of paradoxical atrial undersensing was significantly associated with the sensing threshold of atrial fibrillation (2.7+/-1.5 mV for patients with paradoxical undersensing compared to 1.6+/-1.3 mV for those without, P=0.02). Decreasing the atrial sensing level avoided paradoxical undersensing in 8 of 9 patients while maintaining an adequate safety margin for the detection of atrial fibrillation. CONCLUSION Paradoxical atrial undersensing is inherent to all current dual-chamber pacemakers. The incidence is about 13% when using very high atrial sensing levels. Inappropriate atrial noise reversion can be resolved in most of the cases by decreasing atrial sensing levels and knowledge of this phenomenon is important to avoid unwarranted atrial lead revisions.
Collapse
Affiliation(s)
- Christof Kolb
- Deutsches Herzzentrum München and 1. Med. Klinik, Klinikum rechts der Isar der Technischen Universität München, Munich, Germany.
| | | | | | | |
Collapse
|
15
|
Van Hemel NM, Wohlgemuth P, Engbers JG, Lawo T, Nebaznivy J, Taborsky M, Witte J, Boute W, Munneke D, Van Groeningen C. Form Analysis Using Digital Signal Processing Reliably Discriminates Far-Field R Waves from P Waves. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2004; 27:1615-24. [PMID: 15613124 DOI: 10.1111/j.1540-8159.2004.00694.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
The correct detection of atrial arrhythmias by pacemakers is often limited by the presence of far-field R waves (FFRWs) in the atrial electrogram. Digital signal processing (DSP) of intracardiac signals is assumed to provide improved discrimination between P waves and FFRWs when compared to current methods. For this purpose, 100 bipolar and unipolar intracardiac atrial recordings from 31 patients were collected during pacemaker replacement and used for the off-line application of a novel DSP algorithm. Digital processing of the atrial intracardiac electrogram (IEGM) signals (8 bit, 800 samples/s) included filtering and calculation of the maximum amplitude and slope of the detected events. The form parameter was calculated, being the sum of the most negative value of the amplitude and that of the slope of the detected event. The algorithm collects form parameter data of P waves and FFRWs and composes histograms of these data. A sufficiently large gap between the FFRW and P wave histograms allows discrimination of these two signals based on form parameters. Three independent observers reviewed the reliability of classification with this algorithm. Sensitivity and specificity of FFRW detection were 99.63% and 100%, respectively, and no P waves were falsely classified. It can be concluded that this novel DSP algorithm shows excellent discrimination of FFRWs under off-line conditions and justify the implementation of this algorithm in future pacemakers for real-time discrimination between P waves and FFRWs. This method prevents false mode switching and allows correct and immediate intervention pacing for atrial tachyarrhythmias.
Collapse
Affiliation(s)
- Norbert M Van Hemel
- Heart Lung Center Utrecht, Department of Cardiology, St. Antonius Hospital, Nieuwegein, the Netherlands.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Inama G, Santini M, Padeletti L, Boriani G, Botto G, Capucci A, Gulizia M, Ricci R, Rizzon P, Ferri F, Miraglia F, Raneri R, Grammatico A. Far-Field R Wave Oversensing in Dual Chamber Pacemakers Designed for Atrial Arrhythmia Management:. Effect of Pacing Site and Lead Tip to Ring Distance. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2004; 27:1221-30. [PMID: 15461712 DOI: 10.1111/j.1540-8159.2004.00613.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
INAMA, G., et al.: Far-Field R Wave Oversensing in Dual Chamber Pacemakers Designed for Atrial Arrhythmia Management: Effect of Pacing Site and Lead Tip to Ring Distance. The aim of the study was to determine the incidence and practical implications of far-field R wave oversensing (FFRWO) and its association with pacing site and lead tip to ring spacing (TTRS) in implantable devices designed to diagnose and treat atrial tachyarrhythmias and programmed with a fixed and short postventricular blanking period. The study included 395 patients who were implanted with a DDDRP pacemaker and prospectively followed. At implant and follow-up visits FFRWO was assessed by analyzing lead electrical measures and atrial tachyarrhythmic episodes collected in the device diagnostics. During a median follow-up of 12 months 11 (2.8%) of 395 patients showed a clinically significant FFRWO that induced inappropriate detection or pacemaker malfunctioning. The atrial pacing site of these 11 patients was right atrium appendage (RAA) for 3 patients, representing 1.1% of 254 RAA patients, coronary sinus ostium (CSO) for 7 patients, representing 7.4% of 94 CSO patients (P < 0.005 vs RAA), and lateral wall (LW) for 1 (2.9%) of 34 LW patients. The minimal value of the FFRWO to P wave ratio, measured at implant, associated with a clinically significant FFRWO was 0.6; therefore, a value of 0.5 was used as a cutoff to identify patients at risk of undesirable device behavior induced by FFRWO: there were 11 (9.6%) of 114 of RAA patients with short (< or = 10 mm) TTRS, 22 (18.8%) of 117 of RAA patients with long (> or = 17 mm) TTRS (P < 0.05 vs short TTRS), 21 (30.6%) of 64 of CSO patients short TTRS (P < 0.001 vs RAA patients with short TTRS) and 3 (30%) of 10 of CSO patients with long TTRS. The analysis showed that, despite the short postventricular blanking time, FFRWO inducing undesired functioning in AT500 pacemakers is infrequent (2.8% of patients). Compared to RAA, the CSO lead position was more frequently associated with FFRWO.TTRS < 10 mm was associated with lower risk of clinically significant FFRWO in RAA. (PACE 2004; 27:1221-1230).
Collapse
Affiliation(s)
- Giuseppe Inama
- Institute of Cardiology, Maggiore Hospital, Crema, Italy.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Sweeney MO, Hellkamp AS, Ellenbogen KA, Glotzer TV, Silverman R, Yee R, Lee KL, Lamas GA. Prospective Randomized Study of Mode Switching in a Clinical Trial of Pacemaker Therapy for Sinus Node Dysfunction. J Cardiovasc Electrophysiol 2004; 15:153-60. [PMID: 15028043 DOI: 10.1046/j.1540-8167.2004.03146.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
INTRODUCTION Atrial fibrillation (AF) is common in pacemaker patients with sinus node dysfunction (SND) and may result in rapid ventricular pacing (RVP) in the DDDR mode. Mode switching (MS) reduces RVP, but its clinical benefit in patients with SND is unknown. METHODS AND RESULTS Two hundred two patients in the Mode Selection Trial (MOST; 2,010-patient, 6-year trial of DDDR vs VVIR pacing in SND) randomized to DDDR pacemakers with atrial high-rate episode (AHRE) storage capabilities were subrandomized to MS ON (N = 96) or MS OFF (N = 106). Cardiovascular symptoms, quality of life (QOL), reprogramming due to RVP, death, stroke, and heart failure hospitalization (HFH) were compared between groups. The treatment groups were similar with regard to AF history (59% MS ON vs 57% MS OFF). AHREs occurred in 49% patients during median follow-up of 2.2 years. Median AHRE duration (in min; MS ON 116 vs MS OFF 58, P = 0.29), frequency AHREs/week (MS ON 3.5 vs MS OFF 6.4, P = 0.23), and time spent in AHRE (min/week) (MS ON 450, MS OFF 268) were similar. Reprogramming due to any RVP during AHREs occurred more in MS OFF vs MS ON (13.2% vs 3.1%, P = 0.011) and marginally more for symptomatic RVP (8.5% vs 2.1%, P = 0.062). Cardiovascular symptoms occurred in 93.6% MS ON vs 90.2% MS OFF (P = 0.38). Median number of symptoms reported per visit was similar (MS ON 1.3 vs MS OFF 1.5, P = 0.62). Median symptom frequency/severity, summed and averaged over visits, was similar (MS ON 4.3 vs MS OFF 4.5, P = 0.74). QOL was not different between groups. Death, stroke, and HFH were not different between groups. CONCLUSION MS reduces pacemaker reprogramming due to RVP during AHREs in a small number of patients but does not improve QOL or cardiovascular symptoms overall among patients with SND.
Collapse
Affiliation(s)
- Michael O Sweeney
- Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts 02115, USA.
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Pollak WM, Simmons JD, Interian A, Castellanos A, Myerburg RJ, Mitrani RD. Pacemaker diagnostics: a critical appraisal of current technology. Pacing Clin Electrophysiol 2003; 26:76-98. [PMID: 12685144 DOI: 10.1046/j.1460-9592.2003.00154.x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Diagnostic information retrieved from a pacemaker offers the ability to improve patient care. Pacemaker diagnostic data provides information regarding pacemaker function and activity, lead function, arrhythmia occurrence, and data to aid in optimal pacemaker programming. Current pacemakers incorporate greater storage capabilities, more efficient means of storing and presenting data between follow-up visits, and more options for programming diagnostic functions and algorithms. The cardiac rhythm of the paced patient can be evaluated via real-time intracardiac electrograms at interrogation, surface electrocardiograms, ambulatory electrocardiograms, and by pacemaker stored diagnostic function that may include stored intracardiac electrograms. This article focuses on the various methods of obtaining diagnostic information regarding pacemaker activity, pacemaker function, and diagnostic information on cardiac arrhythmias. The current clinical applicability and limitations of these methods and the use of stored diagnostic data in the clinical follow-up and study of patients with pacemakers is discussed.
Collapse
Affiliation(s)
- Wayne M Pollak
- Department of Medicine, Division of Cardiology, University of Miami Medical Center, Miami, Florida, USA
| | | | | | | | | | | |
Collapse
|
19
|
Stroobandt RX, Barold SS, Vandenbulcke FD, Willems RJ, Sinnaeve AF. A reappraisal of pacemaker timing cycles pertaining to automatic mode switching. J Interv Card Electrophysiol 2001; 5:417-29. [PMID: 11752910 DOI: 10.1023/a:1013298012367] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Automatic mode switching algorithms of dual chamber pacemakers require fundamental changes in the operation of pacemaker timing cycles to optimize detection of supraventricular tachyarrhythmias. The timing cycles related to mode switching are basically independent of the algorithm design. Blanking periods (when the sensing amplifier is temporarily disabled) should be optimized to a relatively small fraction of the pacing cycle to enhance atrial sensing and prevent far-field sensing. This review explains the function of the timing cycles pertaining to mode switching and proposes simpler terminology to facilitate the understanding of pacemaker function and electrographic interpretation of complex recordings.
Collapse
Affiliation(s)
- R X Stroobandt
- Department of Cardiology, AZ Damiaan Hospital, Oostende, Belgium.
| | | | | | | | | |
Collapse
|
20
|
Israel CW, Gascon D, Nowak B, Campanale G, Pascotto P, Hartung W, Lellouche D. Diagnostic value of stored electrograms in single-lead VDD systems. Pacing Clin Electrophysiol 2000; 23:1801-3. [PMID: 11139928 DOI: 10.1111/j.1540-8159.2000.tb07023.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
UNLABELLED Evaluation of the quality of atrial sensing is indispensable to monitor the performance of VDD single-lead systems. In addition to counters, a new VDD system offers storage of intracardiac electrograms (EGMs). The clinical contribution of stored EGMs in a VDD pacemaker was prospectively examined in a multicenter study, and the reliability of its counters was evaluated on the basis of EGM information. METHODS A VDD system (Pulsar 870, Guidant Co.) was implanted in 46 patients with atrioventricular block. EGM storage was activated upon detection of ventricular tachycardia (VT), recurrent premature ventricular complexes (PVCs), and mode switch ("atrial tachy reaction," ATR). Stored EGMs were retrieved before discharge of the patients from the hospital, and at 6-week, 3-month, and 6-month follow-up. RESULTS A total of 440 stored EGMs were retrieved and analyzed. Of 30 VT episodes detected, 2 (7%) were confirmed, and all others were attributable to ventricular oversensing. One postmortem interrogation documented VT as the cause of sudden death. Of 175 EGMs stored upon detection of PVCs, 43 episodes (25%) were confirmed and 124 (70%) showed intermittent atrial undersensing with spontaneous AV conduction; in 8 episodes (5%) no abnormality was observed. Of 235 episodes stored upon ATR, 82 (35%) were confirmed and 153 were due to atrial oversensing. CONCLUSIONS (1). Stored EGMs indicated a high percentage (69%) of event misdiagnosis by the pacemaker. Thus, pacemaker counter information without the availability of stored EGMs should be interpreted with caution. (2). Misclassified events are of high clinical importance since they unmask otherwise unsuspected intermittent under- or oversensing.
Collapse
Affiliation(s)
- C W Israel
- St. Josef-Hospital, Ruhr-University Bochum, Germany
| | | | | | | | | | | | | |
Collapse
|
21
|
Abstract
INTRODUCTION Dual chamber implantable cardioverter defibrillator (ICD) technology extended ICD therapy to more than termination of hemodynamically unstable ventricular tachyarrhythmias. It created the basis for dual chamber arrhythmia management in which dependable detection is important for treatment and prevention of both ventricular and atrial arrhythmias. METHODS AND RESULTS Dual chamber detection algorithms were investigated in two Medtronic dual chamber ICDs: the 7250 Jewel AF (33 patients) and the 7271 Gem DR (31 patients). Both ICDs use the same PR Logic algorithm to interpret tachycardia as ventricular tachycardia (VT), supraventricular tachycardia (SVT), or dual (VT+ SVT). The accuracy of dual chamber detection was studied in 310 of 1,367 spontaneously occurring tachycardias in which rate criterion only was not sufficient for arrhythmia diagnosis. In 78 episodes there was a double tachycardia, in 223 episodes SVT was detected in the VT or ventricular fibrillation zone, and in 9 episodes arrhythmia was detected outside the boundaries of the PR Logic functioning. In 100% of double tachycardias the VT was correctly diagnosed and received priority treatment. SVT was seen in 59 (19%) episodes diagnosed as VT. The causes of inappropriate detection were (1) algorithm failure (inability to fulfill the PR<RP condition in atrial tachyarrhythmias with 1:1 AV conduction, and far-field R wave sensing intermittently present during sinus tachycardia); (2) programming settings (atrial fibrillation/atrial flutter with ventricular rate above the SVT limit); and (3) algorithm limitations (atrial tachycardia with ventricular rate around the shortest programmable SVT limit and SVT redetection following VT therapy). Programming measures improved detection ability in 13 of 59 of inappropriately detected arrhythmias. CONCLUSION Dual chamber detection algorithms evaluated in a subset of diagnostically difficult arrhythmias allow safe detection of double tachycardias but require further extension and programmability to improve VT:SVT discrimination rules.
Collapse
Affiliation(s)
- B Dijkman
- Department of Cardiology, Academic Hospital Maastricht, The Netherlands.
| | | |
Collapse
|