1
|
Abstract
Permanent cardiac pacemakers (PPM) are effective in the treatment of bradycardia in a growing number of clinical scenarios. An appreciation of the capacity of PPMs to result in negative hemodynamic and proarrhythmic effects has grown alongside clinical experience with permanent pacing. Such experience has necessitated the development of algorithms aimed at optimizing device functionality across a broad spectrum of physiologic and pathologic conditions. This review highlights recent device-based algorithms used in automated threshold testing, reduction of right ventricular pacing, prevention and treatment of pacemaker-mediated tachycardia, mode switching for atrial tachyarrhythmias, rate-modulated pacing, and advances in arrhythmia storage and remote monitoring.
Collapse
Affiliation(s)
- Daniel Sohinki
- Division of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9047, USA.
| | - Owen A Obel
- Division of Internal Medicine, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas, TX 75390-9047, USA; Division of Cardiology, Veterans Health Administration (VA) North Texas Healthcare System, 4500 South Lancaster Road, Dallas, TX 75216, USA
| |
Collapse
|
2
|
KREUZER JOERG, LENNERZ CARSTEN, DIETL JOSEFU, BEIER THOMAS, STRAUCH ALEXEJ, SEMMLER VERENA, BADRAN HAITHAM, ZRENNER BERNHARD, KOLB CHRISTOF. Are Plasma Natriuretic Peptide Levels Influenced by Automatic Pacemaker Algorithms for Ventricular Pacing Minimization? Pacing Clin Electrophysiol 2013; 36:424-32. [DOI: 10.1111/pace.12070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2012] [Revised: 10/26/2012] [Accepted: 10/30/2012] [Indexed: 12/01/2022]
Affiliation(s)
- JOERG KREUZER
- Abteilung für Kardiologie; St Vincenz Krankenhaus; Limburg; Germany
| | - CARSTEN LENNERZ
- Deutsches Herzzentrum and 1. Medizinische Klinik rechts der Isar, Faculty of Medicine; Technische Universität München; Munich; Germany
| | - JOSEF U. DIETL
- Medizinische Klinik; Krankenhaus Landshut-Achdorf; Landshut; Germany
| | - THOMAS BEIER
- I. Medizinische Abteilung; Rotkreuzklinikum München; Munich; Germany
| | - ALEXEJ STRAUCH
- Abteilung für Kardiologie; St Vincenz Krankenhaus; Limburg; Germany
| | - VERENA SEMMLER
- Deutsches Herzzentrum and 1. Medizinische Klinik rechts der Isar, Faculty of Medicine; Technische Universität München; Munich; Germany
| | | | | | - CHRISTOF KOLB
- Deutsches Herzzentrum and 1. Medizinische Klinik rechts der Isar, Faculty of Medicine; Technische Universität München; Munich; Germany
| |
Collapse
|
3
|
Chen KP, Xu G, Wu S, Tang B, Wang L, Zhang S. Clinical evaluation of pacemaker automatic capture management and atrioventricular interval extension algorithm. Europace 2012; 15:395-401. [PMID: 23243132 DOI: 10.1093/europace/eus309] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS The present study was to assess the accuracy of automatic atrial and ventricular capture management (ACM and VCM) in determining pacing threshold and the performance of a second-generation automatic atrioventricular (AV) interval extension algorithm for reducing unnecessary ventricular pacing. METHODS AND RESULTS A total of 398 patients at 32 centres who received an EnPulse dual-chamber pacing/dual-chamber adaptive rate pacing pacemaker (Medtronic, Minneapolis, MN, USA) were enrolled. The last amplitude thresholds as measured by ACM and VCM prior to the 6-month follow-up were compared with manually measured thresholds. Device diagnostics were used to evaluate ACM and VCM and the percentage of ventricular pacing with and without the AV extension algorithm. Modelling was performed to assess longevity gains relating to the use of automaticity features. Atrial and ventricular capture management performed accurately and reliably provided complete capture management in 97% of studied patients. The AV interval extension algorithm reduced the median per cent of right ventricular pacing in patients with sinus node dysfunction from 99.7 to 1.5% at 6-month follow-up and in patients with intermittent AV block (excluding persistent 3° AV block) from 99.9 to 50.2%. On the basis of validated modelling, estimated device longevity could potentially be extended by 1.9 years through the use of the capture management and AV interval extension features. CONCLUSION Both ACM and VCM features reliably measured thresholds in nearly all patients; the AV extension algorithm significantly reduced ventricular pacing; and the use of pacemaker automaticity features potentially extends device longevity.
Collapse
Affiliation(s)
- Ke-ping Chen
- Clinical EP Lab and Arrhythmic Center, Fuwai Hospital, Beijing, China
| | | | | | | | | | | | | |
Collapse
|
4
|
Kronborg MB, Poulsen SH, Mortensen PT, Nielsen JC. Left ventricular performance during para-His pacing in patients with high-grade atrioventricular block: an acute study. Europace 2011; 14:841-6. [PMID: 22170898 DOI: 10.1093/europace/eur368] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
AIM To compare changes in left ventricular (LV) performance and mechanical synchrony between atrial-based pacing with intrinsic conduction (AAI), dual-chamber para-His Pacing (DDD-PHP) and dual-chamber right ventricular septal pacing (DDD-RVS) in patients with high-grade atrioventricular block (AVB). METHODS AND RESULTS Patients with high-grade AVB and QRS <120 ms, who had temporary intrinsic atrioventricular (AV) conduction the day after the implantation were included in the study. All patients received a biventricular pacemaker with a para-His lead in the LV port, and a RVS lead in the right ventricular port. Left ventricular three-dimensional echocardiograms, LV outlet tract-velocity time integrals (LVOT-VTI), and LV synchrony with tissue Doppler imaging were recorded during AAI, DDD-PHP, and DDD-RVS. Eleven patients were included. The mean LVOT-VTI was significant lower during DDD-RVS (19.2 ± 5.5 cm) as compared with DDD-PHP (21.4 ± 5.5 cm), P = 0.006 and AAI (21.6 ± 6.8 cm), P = 0.016. The LVEF was higher during AAI than during DDD-PHP (P= 0.02) and DDD-RVS (P< 0.01). The maximal time to peak velocity between basal segments was significant longer with DDD-RVS (95 ± 26 ms) than with AAI (72 ± 30 ms), P = 0.028, whereas no difference was observed between AAI and DDD-PHP (81 ± 42 ms), P = 0.20. CONCLUSIONS Acutely, DDD-PHP preserves LV systolic performance and mechanical synchrony as compared with DDD-RVS.
Collapse
Affiliation(s)
- Mads Brix Kronborg
- Department of Cardiology, Aarhus University Hospital, Skejby, Bendstrupgaardsvej 100, DK-8200 Aarhus N, Denmark.
| | | | | | | |
Collapse
|
5
|
Kronborg MB, Mortensen PT, Gerdes JC, Jensen HK, Nielsen JC. His and para-His pacing in AV block: feasibility and electrocardiographic findings. J Interv Card Electrophysiol 2011; 31:255-62. [PMID: 21465234 DOI: 10.1007/s10840-011-9565-1] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2010] [Accepted: 03/04/2011] [Indexed: 12/13/2022]
Abstract
PURPOSE Right ventricular apical pacing induces a dyssynchronous activation of the left ventricle and is associated with adverse clinical outcome. We aimed to establish permanent His-bundle pacing or para-His pacing in patients with high-grade atrioventricular (AV) block. METHOD We included patients with pacemaker indication due to second- or third-degree AV block, left ventricular ejection fraction >0.40, QRS duration <120 ms, and sinus rhythm. All patients received a pacemaker with one atrial lead, one right ventricular mid-septal lead, and one lead in the His bundle or in the para-His position. Pacing from apex was performed temporarily. Patients were followed for 12 months. RESULTS Thirty-eight patients were included (mean age, 67 ± 10 years; 30 (79%) male). Mean implantation time was 85 ± 31 min, mean fluoroscopy time was 23 ± 13 min, and mean position attempts of the His bundle lead was 8 ± 5. In four patients, we established direct His-bundle pacing with a mean QRS of 100 ± 19 ms, and in 28 patients, para-His pacing was achieved with a mean QRS of 112 ± 18 ms, and in six patients, neither direct His-bundle pacing or para-His pacing could be achieved. The mean QRS duration was 153 ± 12 ms with mid-septal pacing and 161 ± 15 ms with apical pacing. CONCLUSION Stable direct His-bundle pacing or para-His pacing is feasible in 85% of patients with narrow QRS and high-grade AV block and leads to a normal or near-normal ventricular activation pattern.
Collapse
Affiliation(s)
- Mads Brix Kronborg
- Department of Cardiology, Aarhus University Hospital, Skejby, Brendstrupgaardsvej 100, 8200, Aarhus, Denmark.
| | | | | | | | | |
Collapse
|
6
|
KOLB CHRISTOF, SCHMIDT ROLAND, DIETL JOSEFU, WEYERBROCK SONJA, MORGENSTERN MARTIN, FLECKENSTEIN MARTIN, BEIER THOMAS, VON BARY CHRISTIAN, MACKES KARLG, WIDMAIER JOCHEN, KREUZER JÖRG, SEMMLER VERENA, ZRENNER BERNHARD. Reduction of Right Ventricular Pacing with Advanced Atrioventricular Search Hysteresis: Results of the PREVENT Study. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2011; 34:975-83. [DOI: 10.1111/j.1540-8159.2011.03075.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
7
|
Lian J, Garner G, Kratschmer H, Mussig D. Simulation of AV hysteresis pacing using an integrated dual chamber heart and pacer model. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2009:3932-5. [PMID: 19963804 DOI: 10.1109/iembs.2009.5333095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Long term right ventricular apical pacing has been known to have adverse effects in cardiac function. The AV hysteresis (AVH) is a feature existing in many dual-chamber cardiac pacemakers that aims to minimize the right ventricular pacing, but its clinical efficacy remains inconclusive due to conflicting evidence from different studies. We have recently developed a novel integrated dual-chamber heart and pacer (IDHP) model, which can simulate various interactions between intrinsic heart activity and extrinsic cardiac pacing. In this study, we use the IDHP model to simulate various atrio-ventricular (AV) conduction pathologies, and to investigate the effects of an AVH algorithm on reducing right ventricular pacing. Our results show that the efficacy of AVH is dependent on the underlying cardiac conditions. While it can preserve intrinsic conduction during minor or moderate first degree AV block, its efficacy is reduced at higher degree AV block conditions. This pilot study further supports using the IDHP model to design and evaluate more advanced pacemaker algorithms for therapeutic interventions.
Collapse
Affiliation(s)
- Jie Lian
- Micro Systems Engineering, Inc., Lake Oswego, OR 97035, USA.
| | | | | | | |
Collapse
|
8
|
Simantirakis EN, Arkolaki EG, Vardas PE. Novel pacing algorithms: do they represent a beneficial proposition for patients, physicians, and the health care system? Europace 2009; 11:1272-80. [DOI: 10.1093/europace/eup204] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
9
|
Nitardy A, Langreck H, Dietz R, Stockburger M. Reduction of right ventricular pacing in patients with sinus node dysfunction through programming a long atrioventricular delay along with the DDIR mode. Clin Res Cardiol 2008; 98:25-32. [DOI: 10.1007/s00392-008-0716-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2007] [Accepted: 08/19/2008] [Indexed: 11/28/2022]
|
10
|
Wiegand UKH. [Avoidance of ventricular pacing in patients with sinus node disease or intermittent AV block]. Herzschrittmacherther Elektrophysiol 2008; 19:3-10. [PMID: 18330670 DOI: 10.1007/s00399-008-0595-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2008] [Accepted: 02/15/2008] [Indexed: 05/26/2023]
Abstract
In patients with frequent right ventricular stimulation, worsening of heart failure and atrial fibrillation may occur. Avoidance of unnecessary right ventricular pacing is a major requirement for pacemaker selection and programming in patients with sinus node disease or intermittent AV block. In dual chamber pacemakers this goal can be achieved by programming a long AV delay or an AV delay hysteresis. Algorithms that allow AAI pacing in a dual chamber pacing mode and change to DDD mode in case of high degree AV block are a new attempt to avoid unnecessary right ventricular pacing. The article describes various strategies to avoid unnecessary ventricular pacing and discusses their advantages and disadvantages.
Collapse
Affiliation(s)
- U K H Wiegand
- Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Medizinische Klinik II, Ratzeburger Allee 160, 23538 Lübeck, Germany.
| |
Collapse
|
11
|
PÜRERFELLNER HELMUT, BRANDT JOHAN, ISRAEL CARSTEN, SHELDON TODD, JOHNSON JAMES, TSCHELIESSNIGG KARLHEINZ, SPERZEL JOHANNES, BORIANI GIUSEPPE, PUGLISI ANDREA, MILASINOVIC GORAN. Comparison of Two Strategies to Reduce Ventricular Pacing in Pacemaker Patients. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2008; 31:167-76. [DOI: 10.1111/j.1540-8159.2007.00965.x] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
12
|
Wang NC, Passman R, Goldberger JJ. Minimizing ventricular pacing in sinus-node disease. N Engl J Med 2007; 357:2733-4; author reply 2734. [PMID: 18160697 DOI: 10.1056/nejmc072863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
13
|
BERTINI MATTEO, BIFFI MAURO, ZIACCHI MATTEO, VALZANIA CINZIA, SAPORITO DAVIDE, BORIANI GIUSEPPE. Automatic Verification of Ventricular Stimulation: Fusion Management Algorithm. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007; 31:64-9. [DOI: 10.1111/j.1540-8159.2007.00926.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
14
|
Brignole M, Giada F, Raviele A, Blanc JJ. Pacing for syncope: what role? which perspective? Eur Heart J Suppl 2007. [DOI: 10.1093/eurheartj/sum061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
15
|
Sweeney MO, Bank AJ, Nsah E, Koullick M, Zeng QC, Hettrick D, Sheldon T, Lamas GA. Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. N Engl J Med 2007; 357:1000-8. [PMID: 17804844 DOI: 10.1056/nejmoa071880] [Citation(s) in RCA: 330] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND Conventional dual-chamber pacing maintains atrioventricular synchrony but results in high percentages of ventricular pacing, which causes ventricular desynchronization and has been linked to an increased risk of atrial fibrillation in patients with sinus-node disease. METHODS We randomly assigned 1065 patients with sinus-node disease, intact atrioventricular conduction, and a normal QRS interval to receive conventional dual-chamber pacing (535 patients) or dual-chamber minimal ventricular pacing with the use of new pacemaker features designed to promote atrioventricular conduction, preserve ventricular conduction, and prevent ventricular desynchronization (530 patients). The primary end point was time to persistent atrial fibrillation. RESULTS The mean (+/-SD) follow-up period was 1.7+/-1.0 years when the trial was stopped because it had met the primary end point. The median percentage of ventricular beats that were paced was lower in dual-chamber minimal ventricular pacing than in conventional dual-chamber pacing (9.1% vs. 99.0%, P<0.001), whereas the percentage of atrial beats that were paced was similar in the two groups (71.4% vs. 70.4%, P=0.96). Persistent atrial fibrillation developed in 110 patients, 68 (12.7%) in the group assigned to conventional dual-chamber pacing and 42 (7.9%) in the group assigned to dual-chamber minimal ventricular pacing. The hazard ratio for development of persistent atrial fibrillation in patients with dual-chamber minimal ventricular pacing as compared with those with conventional dual-chamber pacing was 0.60 (95% confidence interval, 0.41 to 0.88; P=0.009), indicating a 40% reduction in relative risk. The absolute reduction in risk was 4.8%. The mortality rate was similar in the two groups (4.9% in the group receiving dual-chamber minimal ventricular pacing vs. 5.4% in the group receiving conventional dual-chamber pacing, P=0.54). CONCLUSIONS Dual-chamber minimal ventricular pacing, as compared with conventional dual-chamber pacing, prevents ventricular desynchronization and moderately reduces the risk of persistent atrial fibrillation in patients with sinus-node disease. (ClinicalTrials.gov number, NCT00284830 [ClinicalTrials.gov].).
Collapse
Affiliation(s)
- Michael O Sweeney
- Cardiac Arrhythmia Service, Brigham and Women's Hospital, Boston, MA 02115, USA.
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Padeletti L, Lieberman R, Valsecchi S, Hettrick DA. Physiologic Pacing: New Modalities and Pacing Sites. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29 Suppl 2:S73-7. [PMID: 17169136 DOI: 10.1111/j.1540-8159.2006.00493.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Right ventricular (RV) apical pacing impairs left ventricular function by inducing dys-synchronous contraction and relaxation. Chronic RV apical pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. These observations have raised questions regarding the appropriate pacing mode and site, leading to the introduction of algorithms and new pacing modes to reduce the ventricular pacing burden in dual chamber devices, and a shift of the pacing site away from the RV apex. However, further investigations are required to assess the long-term results of pacing from alternative sites in the right ventricle, because long-term results so far are equivocal. The potential benefit of prophylactic biventricular, mono-chamber left ventricular, and bifocal RV pacing should be explored in selected patients with a narrow QRS complex, especially those with impaired left ventricular function. His bundle pacing is a promising and evolving technique that requires improvements in lead technology.
Collapse
Affiliation(s)
- Luigi Padeletti
- Institute of Internal Medicine and Cardiology, University of Florence, Florence, Italy.
| | | | | | | |
Collapse
|