1
|
Du Y, Di Y, Yang S, Mo F, Cui G, Chen D, Li Y. Association of myopia and astigmatism with postoperative ocular high order aberration after small incision lenticule extraction. BMC Ophthalmol 2024; 24:211. [PMID: 38741093 DOI: 10.1186/s12886-024-03475-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Accepted: 05/02/2024] [Indexed: 05/16/2024] Open
Abstract
OBJECTIVE To investigate the correlation between higher-order aberrations (HOA) after small incision lenticule extraction (SMILE) and the severity of myopia and astigmatism, along with the relevant factors. These findings will provide valuable insights for decreasing the occurrence of HOA after SMILE and enhancing visual quality. METHODS A total of 75 patients (150 eyes) with myopia and astigmatism who underwent SMILE were categorized into four groups based on the severity of myopia and astigmatism: Myopia Group 1 (Group M1, spherical diopter ranged from -1.00 D to -4.00 D), Myopia Group 2 (Group M2, spherical diopter ranged from -4.10 D to -10.00 D), Astigmatism Group 1 (Group A1, cylindrical diopter ranged from 0 D to -1.00 D), and Astigmatism Group 2 (Group A2, cylindrical diopter ranged from -1.10 D to -3.00 D). A comprehensive assessment was performed to examine the association between HOA and various relevant factors, including a detailed analysis of the subgroups. RESULTS Group M1 had significantly lower levels of total eye coma aberration (CA), corneal total HOA (tHOA), internal tHOA, and vertical CA ( Z 3 - 1 ) after SMILE than Group M2 (P < 0.05). Similarly, Group A1 had significantly lower levels of total eye tHOA, CA, trefoil aberration (TA), corneal tHOA, TA, and vertical TA ( Z 3 - 3 ) after SMILE than Group A2 (P < 0.05). Pearson correlation analysis indicated a statistically significant positive relationship between the severity of myopia/astigmatism and most HOA (P < 0.05). Subgroup evaluations demonstrated a notable increase in postoperative HOA associated with myopia and astigmatism in Groups M2 and A2 compared with the control group. Lenticule thickness, postoperative central corneal thickness (CCT), postoperative uncorrected distance visual acuity (UDVA), and postoperative corneal Km and Cyl were strongly correlated with most HOA. Age, eyes, and postoperative intraocular pressure (IOP) were only associated with specific HOA. CONCLUSION HOA positively correlated with the severity of myopia and astigmatism after SMILE. However, this relationship was not linear. HOA after SMILE was influenced by various factors, and additional specialized investigations are required to establish its clinical importance.
Collapse
Affiliation(s)
- Yifan Du
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Yu Di
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Shan Yang
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Fei Mo
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Ge Cui
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Di Chen
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China
| | - Ying Li
- Department of Ophthalmology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, People's Republic of China.
| |
Collapse
|
2
|
Kanclerz P, Bazylczyk N, Przewłócka K, Khoramnia R, Atchison DA, Tuuminen R. Risk Factors for Corneal Monochromatic Aberrations and Implications for Multifocal and Extended Depth-of-Focus Intraocular Lens Implantation. J Refract Surg 2024; 40:e420-e434. [PMID: 38848055 DOI: 10.3928/1081597x-20240416-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2024]
Abstract
PURPOSE To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation. METHODS PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal aberrations as of August 27, 2023. The following keywords were used in various combinations: corneal, aberrations, defocus, astigmatism, spherical aberration, coma, trefoil, quadrafoil, intraocular lens, and IOL. RESULTS Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal astigmatism, particularly concerning trefoil and coma. Increased levels of corneal higher-order aberrations are noted following contact lens wear, in patients with dry eye disease, and with pterygium. Increased higher-order aberrations have been reported following corneal refractive surgery and for 3 months following trabeculectomy; regarding intraocular lens surgery, the results remain controversial. CONCLUSIONS Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises in their design and performance with respect to spherical aberration. Preoperative evaluation is critical for proper IOL choice, particularly in corneas with risk of high levels of aberrations. [J Refract Surg. 2024;40(6):e420-e434.].
Collapse
|
3
|
Hashemi H, Mesbahi S, Jamali A, Ostadimoghaddam H, Yekta A, Khabazkhoob M. The association between ocular biometric components and corneal aberrations. Clin Exp Optom 2023:1-7. [PMID: 37844336 DOI: 10.1080/08164622.2023.2258126] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Accepted: 09/08/2023] [Indexed: 10/18/2023] Open
Abstract
CLINICAL RELEVANCE Evaluating factors affecting corneal higher-order aberration component has a very important role in interpreting the characteristics of the formed image on the retina. BACKGROUND To determine the relationship between ocular biometric components and corneal higher-order aberrations in an elderly population. METHODS This report is related to a subsample of the Tehran Geriatric Eye study (TGES), a population-based cross-sectional study that was conducted on individuals aged 60 years and above in Tehran city, Iran using multistage stratified random cluster sampling. All study participants underwent ocular examinations including visual acuity measurement, refraction and slit-lamp biomicroscopy. Anterior segment imaging and corneal aberrometry were performed using Pentacam AXL. RESULTS In the present study, 644 eyes of 415 individuals (56.9% female) with mean age of 66.36 ± 4.70 years were evaluated. According to a multiple generalised estimating equation model, the root mean square of total higher-order aberrations was related to age (β = 0.081, p = 0.002), crystalline lens thickness (β = 0.08, p < 0.001), and corneal diameter (β = -0.04, p = 0.014). The root mean square of total coma aberration was directly related to the female sex (β = 0.02, p = 0.05), and crystalline lens thickness (β = 0.06, p < 0.001). There was a direct relationship between the root mean square of third- and fourth-order higher-order aberrations and crystalline lens thickness (p < 0.001). Spherical aberration was directly related to the male sex (β = -0.02, p = 0.004), axial length (β = 0.05, p < 0.001) and central corneal thickness (β = 0.001, p = 0.025), and was inversely related to anterior chamber depth (β = -0.07, p = 0.031) and crystalline lens thickness (β = -0.25, p < 0.001). CONCLUSION Ocular biometric components are related to corneal aberrations in the elderly. These factors need to be considered in respect of medical and surgical procedures required for the elderly.
Collapse
Affiliation(s)
- Hassan Hashemi
- Noor Research Center for Ophthalmic Epidemiology, Noor Eye Hospital, Tehran, Iran
| | - Shima Mesbahi
- Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Alireza Jamali
- Rehabilitation Research Center, Department of Optometry, Iran University of Medical Sciences, Tehran, Iran
| | - Hadi Ostadimoghaddam
- Refractive Errors Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Abbasali Yekta
- Department of Optometry, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mehdi Khabazkhoob
- Department of Basic Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Hernández CS, Gil A, Casares I, Poderoso J, Wehse A, Dave SR, Lim D, Sánchez-Montañés M, Lage E. Prediction of manifest refraction using machine learning ensemble models on wavefront aberrometry data. JOURNAL OF OPTOMETRY 2022; 15 Suppl 1:S22-S31. [PMID: 35431181 PMCID: PMC9732475 DOI: 10.1016/j.optom.2022.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/28/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
PURPOSE To assess the performance of machine learning (ML) ensemble models for predicting patient subjective refraction (SR) using demographic factors, wavefront aberrometry data, and measurement quality related metrics taken with a low-cost portable autorefractor. METHODS Four ensemble models were evaluated for predicting individual power vectors (M, J0, and J45) corresponding to the eyeglass prescription of each patient. Those models were random forest regressor (RF), gradient boosting regressor (GB), extreme gradient boosting regressor (XGB), and a custom assembly model (ASB) that averages the first three models. Algorithms were trained on a dataset of 1244 samples and the predictive power was evaluated with 518 unseen samples. Variables used for the prediction were age, gender, Zernike coefficients up to 5th order, and pupil related metrics provided by the autorefractor. Agreement with SR was measured using Bland-Altman analysis, overall prediction error, and percentage of agreement between the ML predictions and subjective refractions for different thresholds (0.25 D, 0.5 D). RESULTS All models considerably outperformed the predictions from the autorefractor, while ASB obtained the best results. The accuracy of the predictions for each individual power vector component was substantially improved resulting in a ± 0.63 D, ±0.14D, and ±0.08 D reduction in the 95% limits of agreement of the error distribution for M, J0, and J45, respectively. The wavefront-aberrometry related variables had the biggest impact on the prediction, while demographic and measurement quality-related features showed a heterogeneous but consistent predictive value. CONCLUSIONS These results suggest that ML is effective for improving precision in predicting patient's SR from objective measurements taken with a low-cost portable device.
Collapse
Affiliation(s)
- Carlos S Hernández
- Department of Electronics and Communications Technology, Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain; PlenOptika, Inc., Boston, MA, USA; Instituto de Investigación Sanitaria Fundación Jiménez Diaz, Madrid, Spain
| | - Andrea Gil
- Department of Electronics and Communications Technology, Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain; PlenOptika, Inc., Boston, MA, USA; Instituto de Investigación Sanitaria Fundación Jiménez Diaz, Madrid, Spain
| | - Ignacio Casares
- Department of Electronics and Communications Technology, Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain; Instituto de Investigación Sanitaria Fundación Jiménez Diaz, Madrid, Spain
| | - Jesús Poderoso
- Department of Electronics and Communications Technology, Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain; Instituto de Investigación Sanitaria Fundación Jiménez Diaz, Madrid, Spain
| | | | | | | | - Manuel Sánchez-Montañés
- Department of Computer Science. Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain
| | - Eduardo Lage
- Department of Electronics and Communications Technology, Escuela Politécnica Superior, Universidad Autónoma de Madrid, Spain; PlenOptika, Inc., Boston, MA, USA; Instituto de Investigación Sanitaria Fundación Jiménez Diaz, Madrid, Spain.
| |
Collapse
|
5
|
Gui X, Zhang R, Li S, Zhao N, Zhang HR, Zhou YK, Huan CY, Zhao CY, Wang HY, Song HY, Shen W, Zhang JH. Comparative analysis of the clinical outcomes between wavefront-guided and conventional femtosecond LASIK in myopia and myopia astigmatism. Int J Ophthalmol 2021; 14:1581-1588. [PMID: 34667736 DOI: 10.18240/ijo.2021.10.16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 08/20/2021] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the clinical outcomes of wavefront guided femtosecond LASIK (WFG LASIK) and conventional femtosecond LASIK (NWFG LASIK) in eyes with myopia and myopia astigmatism. METHODS This was a retrospective, nonrandomized, comparative investigation enrolling 236 eyes of 122 patients (18-50y) with low & moderate and high myopia. The WFG group including 97 eyes (50 patients) undergone WFG LASIK and the NWFG group including 139 eyes (72 patients) undergone conventional LASIK. Mean efficacy index, high order aberrations (HOAs), pupil size and the quality of visual questionnaire were evaluated 6mo postoperatively. RESULTS There is no difference between WFG group (-0.054±0.049 in logMAR) and NWFG group (-0.040±0.056) in uncorrected distance visual acuity (UDVA) postoperatively. The myopia astigmatism is higher in WFG group than that in NWFG group (P<0.05). However, the mean efficacy index (MEI) in the WFG group (1.09±0.106) is better than that in the NWFG group (1.036±0.124; P<0.001). Increased HOAs were observed in NWFG group (0.30±0.196) than that in WFG group (0.146±0.188; P<0.001). The pupil size is larger in WFG group (5.15±0.76 mm) than that in NWFG group (4.32±0.52 mm). The patients are satisfied with the clinical surgery, yet WFG group showed better visual quality using the questionnaire survey. Meanwhile, high myopia would result in worse MEI, HOAs and visual quality than low & moderate myopia. CONCLUSION WFG and NWFG FS-LASIK are both effective and safe procedures to correct low & moderate and high myopia, but WFG FS-LASIK gives a better postoperative MEI, aberrometric control and predictable outcome. Meanwhile, WFG FS-LASIK is better than NWFG FS-LASIK in correction of myopia astigmatism. Low & moderate myopia allow better clinical outcomes than high myopia using any surgical method.
Collapse
Affiliation(s)
- Xiao Gui
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Rui Zhang
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Sha Li
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Na Zhao
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Hao-Rui Zhang
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Yu-Kun Zhou
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Chen-Yang Huan
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Chun-Yan Zhao
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Hong-Ying Wang
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Hong-Yuan Song
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China.,Department of Ophthalmology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
| | - Wei Shen
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| | - Jian-Hua Zhang
- Department of Ophthalmology, the First Affiliated Hospital of Naval Medical University, Shanghai 200433, China
| |
Collapse
|
6
|
Alzaben Z, Gammoh Y, Freixas M, Zaben A, Zapata MA, Koff DN. <p>Inter-Ocular Asymmetry in Anterior Corneal Aberrations Using Placido Disk-Based Topography</p>. Clin Ophthalmol 2020; 14:1451-1457. [PMID: 32546953 PMCID: PMC7266388 DOI: 10.2147/opth.s255086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Objective Inter-ocular asymmetry in anterior corneal high-order aberrations has previously not been investigated. This study aims to investigate the normal range of inter-ocular asymmetry in corneal high-order aberrations (HOAs) using a Placido disk-based corneal topographer to explore the relationship between the HOA parameters of the anterior corneal for each eye individually and the refractive error. Patients and Methods A total of 257 subjects (98 males and 159 females) were participated, with an age range of 6 to 81 years (average of 40.2 ±17.53). Participants were divided into three groups: myopia (spherical equivalent (SEQ) of refraction ≥−0.50 D), hypermetropia (SEQ ≥+0.50 D), and emmetropia. For all patients, high-order aberrations were measured using a corneal topographer (CA.200TM; Topcon). Inter-ocular asymmetry was represented by RMS (root mean square) for three, five, and seven mm as pupil entry; aberrations for five mm pupil (vertical and oblique trefoil, vertical and horizontal comma, and primary spherical aberration) were recorded using the instrument’s built-in software. Results Hypermetropes exhibit the highest inter-ocular asymmetry of all RMS values, mostly in spherical aberrations, and higher-order trefoil values. Oblique trefoil aberrations had the highest interocular asymmetry in the myopic groups. The interocular asymmetry in horizontal coma values was the highest in emmetropes and the lowest in hypermetropes. Conclusion To our knowledge, this is the first observational study of inter-ocular differences in high-order aberrations of the anterior corneal surface of the human eye. This study’s results could be used to establish normal values of inter-ocular asymmetry of HOAs of the anterior cornea. The use of such normal values should be investigated further to serve as a guideline for clinicians when establishing the best management route for the patient’s refractive error.
Collapse
Affiliation(s)
- Zeyad Alzaben
- Department of Optometry, Opticalia Clinic, Olot, Spain
- Correspondence: Zeyad Alzaben Department of Optometry, Opticalia Clinic, (Plz/Clarà, 12), Olot, Catalonia17800, SpainTel +34 678922564 Email
| | - Yazan Gammoh
- Department of Optometry, Opticalia Clinic, Olot, Spain
- Department of Optometry Science, Faculty of Allied Medical Sciences, Al-Ahliyya Amman University, Amman, Jordan
| | - Marta Freixas
- Department of Optometry, Opticalia Clinic, Olot, Spain
| | | | - Miguel A Zapata
- Ophthalmology Department, Vall d’Hebron Hospital, Barcelona, Spain
| | - Dana N Koff
- Department of Optometry Science, Faculty of Allied Medical Sciences, Al-Ahliyya Amman University, Amman, Jordan
| |
Collapse
|
7
|
Fu D, Zeng L, Zhao J, Miao HM, Yu ZQ, Zhou XT. Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision. BMC Ophthalmol 2018; 18:131. [PMID: 29855287 PMCID: PMC5984466 DOI: 10.1186/s12886-018-0794-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2018] [Accepted: 05/22/2018] [Indexed: 12/02/2022] Open
Abstract
Background To investigate the safety and optical quality of small-incision lenticule extraction (SMILE) combined with monovision, and patient satisfaction with the procedure. Methods The present study assessed a non-random case series involving 60 eyes of 30 patients (mean age 45.53 ± 3.20 years [range 41 to 52 years]) treated bilaterally using the VisuMax 500 system (Carl Zeiss Meditec, Jena, Germany) between January and July 2016. The target refraction was plano for the distance eye, and between − 0.5 and − 1.75 diopters (D) for the near eye. Visual acuity, refraction errors, ocular aberrations, and satisfaction questionnaire scores were calculated 1 year after surgery. Results All surgeries were uneventful, with a mean safety index of 1.03 and 1.04 in dominant and nondominant eyes, respectively. Binocular uncorrected distance visual acuity of all patients was ≥20/32, while binocular uncorrected near visual acuity was ≥20/40 1 year postoperatively. Higher-order aberration (0.45 ± 0.14, 0.51 ± 0.15 μm), spherical (0.18 ± 0.15, 0.21 ± 0.14 μm) and coma aberration (0.31 ± 0.16, 0.27 ± 0.17 μm) were identical between dominant and nondominant eyes after surgery. The overall satisfaction rate was 86.7% (26/30), with large contributions from age (OR = 1.76 95% CI: 1.03–2.53; P = 0.036). Binocular uncorrected distance visual acuity was related to preoperative spherical diopter (r = − 0.500; P = 0.005). Conclusions Monovision appears to be a safe and effective option for myopia patients with presbyopia who are considering the SMILE procedure. Patients with younger age were more satisfied with the procedure.
Collapse
Affiliation(s)
- Dan Fu
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Li Zeng
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Jing Zhao
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Hua-Mao Miao
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
| | - Zhi-Qiang Yu
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia (Fudan University), No. 83 FenYang Road, Shanghai, 200031, People's Republic of China
| | - Xing-Tao Zhou
- Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China. .,NHC Key Laboratory of Myopia (Fudan University), No. 83 FenYang Road, Shanghai, 200031, People's Republic of China.
| |
Collapse
|
8
|
Reliability of Ocular Aberration Measurements in Children with Moderate and Low Myopia under Scotopic Conditions. J Ophthalmol 2018; 2018:2043718. [PMID: 29607213 PMCID: PMC5828559 DOI: 10.1155/2018/2043718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 11/19/2017] [Accepted: 11/30/2017] [Indexed: 11/17/2022] Open
Abstract
Purpose To investigate the reliability of ocular aberration measurement in myopic children under scotopic conditions and to validate the mathematical Zernike pupil scaling-down technique. Methods Ocular aberrations of 45 myopic children were examined under scotopic conditions via iTrace aberrometer. The intra- and intersession repeatability was evaluated for both the measured values with the true pupil sizes and the estimated ones that were determined by scaling down the pupil sizes to the largest integer value across all measurements. Results The intra- and intersession difference of clinically measured aberration was generally insignificant, and the ICCs for each aberration component exhibited good to excellent reliability (ICCs > 0.4). Similar results were found for the estimated aberration using the scaling-down technique. Although the majority of the estimated Zernike components were comparable with the corresponding measured one, the estimated values of defocus, coma, and the corresponding total aberrations were found significantly smaller than the measured values (all P < 0.01). Conclusions The ocular aberration measurements in myopic children under the circumstances described are reliable. The scaling-down technique is a useful option for comparing the results obtained from different pupil sizes, but the estimated Zernike coefficients were not always comparable with the corresponding measured values.
Collapse
|
9
|
Kobayashi N, Hirooka K, Nitta E, Ukegawa K, Tsujikawa A. Visual acuity and corneal higher-order aberrations after EX-PRESS or trabeculectomy, and the determination of associated factors that influence visual function. Int Ophthalmol 2017; 38:1969-1976. [PMID: 28799080 DOI: 10.1007/s10792-017-0685-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Accepted: 08/01/2017] [Indexed: 11/30/2022]
Abstract
PURPOSE This study investigated postoperative visual acuity and corneal higher-order aberrations following EX-PRESS or trabeculectomy. METHODS Out of 56 eyes of 56 patients analyzed, 30 eyes were treated using trabeculectomy, while 26 eyes were treated with EX-PRESS. Visual acuity and corneal higher-order aberrations were analyzed in both groups before and at 2 weeks, 1, 2, and 3 months after the surgeries. Risk factors that could potentially influence corneal higher-order aberrations were evaluated. RESULTS Significant reductions in the IOP were observed at 3 months after the surgery in both groups. Although a significant decrease in the visual acuity (logMAR) was observed at 2 weeks after the surgery in both groups, at 1 month after the surgeries, there were no significant differences found for the vision as compared to the baseline. At each study visit in the trabeculectomy group, significantly higher corneal higher-order aberrations compared to baseline were noted. In the EX-PRESS group, however, these aberrations were no longer significantly different from the baseline at month 2 (P = 0.36). Analysis of the risk factors indicated that hypotony could influence corneal higher-order aberrations after surgery. CONCLUSIONS Corneal higher-order aberrations were significantly increased at 1 month after EX-PRESS treatment, with levels returning to baseline by 2 months. After trabeculectomy, however, corneal higher-order aberrations remained significantly increased at 3 months after the procedure.
Collapse
Affiliation(s)
- Nobuko Kobayashi
- Department of Ophthalmology, Kagawa University Faculty of Medicine, 1750-1 Ikenobe, Miki, Kagawa, 761-0793, Japan
| | - Kazuyuki Hirooka
- Department of Ophthalmology, Kagawa University Faculty of Medicine, 1750-1 Ikenobe, Miki, Kagawa, 761-0793, Japan.
| | - Eri Nitta
- Department of Ophthalmology, Kagawa University Faculty of Medicine, 1750-1 Ikenobe, Miki, Kagawa, 761-0793, Japan
| | - Kaori Ukegawa
- Department of Ophthalmology, Kagawa University Faculty of Medicine, 1750-1 Ikenobe, Miki, Kagawa, 761-0793, Japan
| | - Akitaka Tsujikawa
- Department of Ophthalmology, Kagawa University Faculty of Medicine, 1750-1 Ikenobe, Miki, Kagawa, 761-0793, Japan
| |
Collapse
|
10
|
Park YM, Choi BJ, Lee JS. Effect of incision types for Artisan phakic intraocular lens implantation on ocular higher order aberrations. Int J Ophthalmol 2016; 9:1785-1789. [PMID: 28003980 DOI: 10.18240/ijo.2016.12.14] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2015] [Accepted: 01/12/2016] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the effect of incision types for Artisan phakic intraocular lens (PIOL) implantation on ocular higher-order aberrations (HOAs). METHODS A retrospective review was conducted of the patients who had undergone Artisan PIOL implantation for the correction of myopia and followed up for at least 6mo. Patients are classified into 2 groups considering the incision type: cornea group with patients undergone clear corneal incision; sclera group with patients undergone sclera tunnel incision. All patients with postoperative astigmatism of under 1 diopter (D) were included to minimize the effect of residual astigmatism on postoperative HOAs. Visual acuity, special equivalents, astigmatism, predictability (±1 D from target refraction), HOAs (coma, trefoil, spherical aberration), and corneal endothelial counts were analyzed preoperatively and 6mo postoperatively. RESULTS At the postoperative 6mo, all patients of both groups achieved uncorrected visual acuity of 16/20 or better, and significantly decreased the spherical equivalents compared with preoperative values. The predictability of refractive correction was 96% in the former, and 94% in the latter. Unlike the sclera group, preoperative astigmatism decreased significantly in cornea group at postoperative 6mo. The HOAs increased significantly at postoperative 6mo compared to the preoperative values in both groups, and the root mean square (RMS) total and trefoil wavefront aberration of cornea group were significantly higher than those of sclera group. CONCLUSION Although corneal incision significantly reduces preexisting astigmatism, the postoperative 6mo of total RMS and trefoil aberration change may deteriorate the visual quality after Artisan PIOL implantation.
Collapse
Affiliation(s)
- Young Min Park
- Department of Ophthalmology, Gyeongsang National University School of Medicine, Gyeongsang National University Changwon Hospital, 11 Samjeongja-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do 51472, Korea
| | | | - Jong Soo Lee
- Department of Ophthalmology, School of Medicine, Pusan National University and Medical Research Institute, Pusan National University Hospital, Pusan 602-739, Korea
| |
Collapse
|
11
|
Objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity. Eye (Lond) 2016; 31:452-459. [PMID: 27858933 DOI: 10.1038/eye.2016.239] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2015] [Accepted: 08/30/2016] [Indexed: 12/22/2022] Open
Abstract
PurposeTo explore the objective functional visual outcomes of cataract surgery in patients with good preoperative visual acuity.MethodsWe enrolled 130 cataract patients whose best-corrected visual acuity (BCVA) was 20/40 or better preoperatively. Objective visual functions were evaluated with a KR-1W analyzer before and at 1 month after cataract surgery.ResultsThe nuclear (N), cortical (C), and N+C groups had very high preoperative ocular and internal total high-order aberrations (HOAs), coma, and abnormal spherical aberrations. At 1 month after cataract surgery, in addition to the remarkable increase of both uncorrected visual acuity and BCVA, both ocular and internal HOAs in the three groups decreased significantly after cataract surgery (all P<0.05). Point spread function and modulation transfer functions were also improved significantly in these patients (all P<0.05).ConclusionsThe objective functional vision of patients with 20/40 or better preoperative BCVA improved significantly after cataract surgery. This finding shows that the arbitrary threshold of BCVA worse than 20/40 in China cannot always be used to determine who will benefit from cataract surgery.
Collapse
|
12
|
Khan MS, Humayun S, Fawad A, Ishaq M, Arzoo S, Mashhadi F. Comparison of higher order aberrations in patients with various refractive errors. Pak J Med Sci 2015; 31:812-5. [PMID: 26430409 PMCID: PMC4590385 DOI: 10.12669/pjms.314.7538] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To compare the mean root mean square (RMS) of total higher order aberrations (HOAs), coma and spherical aberrations in individuals with myopia, hypermetropia and myopic astigmatism. METHODS This prospective analytical study was conducted at Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan from Jan 2014 to Dec 2014. Two hundred eyes of 121 patients with age ranging from 18-40 years were included in the study. Patients were divided into 4 group namely Low myopia, High myopia, Astigmatism and Hypermetropia on the basis of refractive error. Included were the patients who had refractive error more than ± 0.5D and best corrected visual acuity (BCVA) of 0.00 or better. Patients who had history of surgery and / or eye disease were excluded from the study. Visual acuity (VA), Spherical equivalent (SE) of refractive error, RMS value of total HOAs, coma and spherical aberrations were evaluated. HOAs were measured with aberrometer (Wavelight analyzer version 1073) at 6 mm pupil size. RESULTS Age of the patients ranged from 18 years to 40 years with mean age of 29.10±10.6 years. Seventy one (35.5%) were males and 129 (64.5%) were female. Mean RMS value of HOAs, coma and spherical aberrations was calculated in all four groups. RMS of total HOAs and spherical aberrations in hypermetropia was 0.96±0.96 and 0.30±0.42 respectively and it was higher than other three groups. CONCLUSIONS In overall comparison the mean RMS of total HOAs and spherical aberrations was significantly increased in hypermetropia group and there was a statistically significant negative correlation of SE of hypermetropia with RMS of total HOAs and spherical aberration.
Collapse
Affiliation(s)
- Muhammad Saim Khan
- Dr. Muhammad Saim Khan, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| | - Sadia Humayun
- Dr. Sadia Humayun, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| | - Aisha Fawad
- Dr. Aisha Fawad, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| | - Mazhar Ishaq
- Prof. Dr. Mazhar Ishaq, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| | - Sabahat Arzoo
- Miss. Sabahat Arzoo, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| | - Fawad Mashhadi
- Dr. Fawad Mashhadi, Armed Forces Institute of Ophthalmology, Rawalpindi, Pakistan
| |
Collapse
|
13
|
Zhu X, Ye H, Yang J, Lu Y. Effect of pupil size on higher-order aberrations in high-myopic pseudophakic eyes with posterior staphyloma. Eye (Lond) 2014; 29:98-105. [PMID: 25323850 DOI: 10.1038/eye.2014.242] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2013] [Accepted: 09/10/2014] [Indexed: 01/19/2023] Open
Abstract
PURPOSE To evaluate the effect of pupil size on higher-order aberrations (HOAs) in high-myopic pseudophakic eyes with posterior staphyloma using KR-1W aberrometer. METHODS Forty eyes of 40 high-myopic cataract patients with posterior staphyloma and 20 eyes of 20 age-related cataract patients with normal axial length were recruited. At 1 month after phacoemulsification and intraocular lens implantation, ocular and internal HOAs as well as the visual quality data in the two groups were evaluated with KR-1W analyzer before and after mydriasis. RESULTS Compared with normal axial length eyes, high-myopic pseudophakic eyes with posterior staphyloma had significantly lower values of internal coma both under 4-mm and 6-mm pupil sizes (P<0.001 and 0.020), as well as internal total HOAs (P<0.001) and third-order aberrations at 6-mm pupil size (P=0.018). Statistically significant differences were also found in the variation from 4- to 6-mm pupil sizes for internal coma (P=0.001), internal third-order aberrations (P=0.009), internal total HOAs (P=0.007), and ocular coma aberrations (P=0.006) between two groups. After mydriasis, Strehl ratio increased significantly in high-myopic eyes, whereas decreased slightly in normal axial length eyes (P=0.032 when compared with the variation between the two groups). Statistically significant differences were also found for the variation of modulation transfer functions (MTFs) at frequencies of 15, 30, 45, and 60 cycles/degree between the two groups (P=0.002, 0.002, 0.004, and 0.010, respectively). CONCLUSIONS High-myopic pseudophakic eyes with posterior staphyloma had significantly lower internal coma and less coma variations during mydriasis.
Collapse
Affiliation(s)
- X Zhu
- Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
| | - H Ye
- Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
| | - J Yang
- Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
| | - Y Lu
- Department of Ophthalmology, Eye and Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
| |
Collapse
|
14
|
Lyall DAM, Srinivasan S, Gray LS. Changes in ocular monochromatic higher-order aberrations in the aging eye. Optom Vis Sci 2014; 90:996-1003. [PMID: 23839701 DOI: 10.1097/opx.0b013e31829cac79] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To characterize corneal, internal, and total ocular monochromatic higher-order aberration (MHOA) changes that occur in the aging eye. METHODS Prospective observational case series including 300 eyes of 167 patients (mean age = 63.8 years) attending the ophthalmology service at University Hospital Ayr, Scotland. Corneal, internal, and total ocular aberrations were measured over a 6-mm dilated pupil. Zernike coefficients were obtained to the sixth order. Changes in MHOA between age groups and inter-eye correlations between right and left eyes were analyzed. RESULTS A significant inter-eye correlation was found for refractive mean spherical equivalent and cylinder. A significant inter-eye correlation for the whole eye, corneal, and internal MHOA was found (p < 0.001). Right eye analysis found a significant positive correlation between age and the root mean square of whole eye MHOA (p = 0.012), with an increase from 0.517 μm in the fifth decade to 0.824 μm in the ninth. Total internal MHOA increased from 0.411 to 0.704 μm. A significant positive correlation was found between age and internal fourth- (p = 0.007), fifth- (p = 0.029), and sixth-order (p = 0.025) root mean square aberrations. There were no significant age-related changes in corneal MHOA or corneal spherical aberration. Overall mean (SD) corneal SA was 0.203 (0.082) μm. CONCLUSIONS A strong correlation between the right and left eyes exists for MHOA. Whole eye MHOA increases with age. Such changes can be attributed to age-related changes in the internal optical quality of the eye. Such normative data are useful to the cataract surgeon when considering the use of an aspherical IOL to counteract corneal-induced SA during cataract surgery.
Collapse
Affiliation(s)
- Douglas A M Lyall
- Department of Ophthalmology, University Hospital Ayr, NHS Ayrshire and Arran, Glasgow, Scotland, United Kingdom
| | | | | |
Collapse
|
15
|
Hashemian SJ, Soleimani M, Foroutan A, Joshaghani M, Ghaempanah MJ, Jafari ME, Yaseri M. Ocular higher-order aberrations and mesopic pupil size in individuals screened for refractive surgery. Int J Ophthalmol 2012; 5:222-5. [PMID: 22762055 DOI: 10.3980/j.issn.2222-3959.2012.02.21] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2011] [Accepted: 03/10/2012] [Indexed: 11/02/2022] Open
Abstract
AIM To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. METHODS Ocular HOAs and mesopic pupil size were studied in 2 458 eyes of 1 240 patients with myopia, myopic astigmatism and compound myopic astigmatism and 215 eyes of 110 patients with hyperopia, hyperopic astigmatism and compound hyperopic astigmatism using the Zywave aberrometer (Busch& Lomb). All patients had correctable refractive errors without a history of refractive surgery or underlying diseases. Root-mean-square values of HOAs, total spherical aberration, total coma and mesopic pupil size were analyzed. Ocular HOAs were measured across a ≥ 6.0 mm pupil, and pupil size measurements were performed under the mesopic condition. RESULTS The mean values of HOAs, total spherical aberration and total coma in the myopic group were 0.369µm, ±0.233, 0.133± 0.112µm and 0.330±0.188µm, respectively. In the hyperopic group the mean values of HOAs, total spherical aberration and total coma were 0.418µm ±0.214, 0.202±0.209µm and 0.343±0.201µm, respectively. Hyperopes showed greater total HOAs (P<0.01) and total spherical aberration (P<0.01) compared to myopes. In age-matched analysis, only the amount of total spherical aberration was higher in the hyperopic group (P=0.05). Mesopic pupil size in the myopic group was larger (P≤0.05). CONCLUSION The results suggested that significant levels of HOAs were found in both groups which are important for planning refractive surgeries on Iranians. There were significantly higher levels of total spherical aberration in hyperopes compared to myopes. Mesopic pupil size was larger in myopic group.
Collapse
Affiliation(s)
- Seyed Javad Hashemian
- Eye Research center, Rasoul Akram Hospital Tehran University of Medical Sciences, Tehran, Iran
| | | | | | | | | | | | | |
Collapse
|
16
|
Method for expressing clinical and statistical significance of ocular and corneal wave front error aberrations. Cornea 2012; 31:212-21. [PMID: 22157570 DOI: 10.1097/ico.0b013e318221ce7d] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE The significance of ocular or corneal aberrations may be subject to misinterpretation whenever eyes with different pupil sizes or the application of different Zernike expansion orders are compared. A method is shown that uses simple mathematical interpolation techniques based on normal data to rapidly determine the clinical significance of aberrations, without concern for pupil and expansion order. METHODS Corneal topography maps (TOMEY, Inc, Nagoya, Japan) from 30 normal corneas were collected, and the corneal wave front error was analyzed by Zernike polynomial decomposition into specific aberration types for pupil diameters of 3, 5, 7, and 10 mm and Zernike expansion orders of 6, 8, 10, and 12. Using this 4 × 4 matrix of pupil sizes and fitting orders, the best-fitting 3-dimensional functions were determined for the mean and standard deviation of the root-mean-square error for specific aberrations. The functions were encoded into a software application to determine the significance of data acquired from nonnormal cases. RESULTS The best-fitting functions for 6 types of aberrations were determined: defocus, astigmatism, prism, coma, spherical aberration, and all higher-order aberrations. A clinical screening method of color coding the significance of aberrations in normal, postoperative laser in situ keratomileusis, and keratoconus cases having different pupil sizes and different expansion orders is demonstrated. CONCLUSIONS A method to calibrate wave front aberrometry devices using a standard sample of normal cases was devised. This method could be potentially useful in clinical studies involving patients with uncontrolled pupil sizes or in studies that compare data from aberrometers that use different Zernike fitting-order algorithms.
Collapse
|
17
|
Jang JY, Oh HJ, Yoon KC. Changes of Higher-Order Aberrations after Microcoaxial Cataract Surgery According to Pupil Size. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2012. [DOI: 10.3341/jkos.2012.53.9.1260] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Jae Yong Jang
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| | - Han Jin Oh
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| | - Kyung Chul Yoon
- Department of Ophthalmology, Chonnam National University Medical School, Gwangju, Korea
| |
Collapse
|
18
|
Kamiya K, Umeda K, Igarashi A, Ando W, Shimizu K. Factors influencing the changes in coma-like aberrations after myopic laser in situ keratomileusis. Curr Eye Res 2011; 36:905-9. [PMID: 21950695 DOI: 10.3109/02713683.2011.593729] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To assess factors affecting changes in coma-like aberrations after myopic laser in situ keratomileusis (LASIK). METHODS We retrospectively examined 91 eyes of 48 patients undergoing LASIK (mean patient age ± standard deviation, 29.6 ± 8.1 years; gender, 29 male and 19 female; manifest refraction, -4.76 ± 1.42 diopters). We quantitatively assessed the values of coma-like aberrations for 4-mm and 6-mm pupils using a Hartmann-Shack aberrometer before and 3 months after surgery. Multiple regression analysis was used to assess the relevant factors of the changes in coma-like aberrations. RESULTS The mean changes in coma-like aberrations for 4-mm and 6-mm pupils were 0.08 ± 0.09 μm and 0.31 ± 0.30 μm, respectively. Explanatory variables relevant to the changes in coma-like aberrations were, in order of influence, amount of spherical equivalent correction (partial regression coefficient B = 0.022, p <0.001 for a 4-mm pupil, B = 0.090, p <0.001 for a 6-mm pupil), and surgical technique (B = -0.062, p = 0.01 for a 4-mm pupil, B = -0.169, p = 0.03 for a 6-mm pupil). No significant correlation was seen with other clinical factors such as age, gender, astigmatism correction, mean keratometric readings, central corneal thickness, or eye tracking (with or without). CONCLUSIONS High myopic eyes requiring larger amounts of laser correction and eyes undergoing conventional LASIK tend to induce more coma-like aberration after surgery. Wavefront-guided LASIK may be a better surgical approach for preventing the induction of coma-like aberrations, especially in eyes with high myopia.
Collapse
Affiliation(s)
- Kazutaka Kamiya
- Department of Ophthalmology, University of Kitasato School of Medicine, Sagamihara, Kanagawa, Japan.
| | | | | | | | | |
Collapse
|
19
|
Patient Evaluation and Selection in Refractive Surgery. Cornea 2011. [DOI: 10.1016/b978-0-323-06387-6.00166-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
20
|
Takmaz T, Genç I, Yildiz Y, Can I. Ocular wavefront analysis and contrast sensitivity in eyes implanted with AcrySof IQ or AcrySof Natural intraocular lenses. Acta Ophthalmol 2009; 87:759-63. [PMID: 18976313 DOI: 10.1111/j.1755-3768.2008.01339.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
PURPOSE This study aimed to compare ocular wavefront aberrations for pupil diameters of 4 mm and 6 mm, and contrast sensitivity, in eyes with AcrySof IQ and AcrySof Natural intraocular lenses (IOLs). METHODS Sixty eyes of 60 patients were enrolled in this prospective randomized study. After phacoemulsification the eyes received either AcrySof IQ SN60WF or AcrySof Natural SN60AT IOLs. One month after surgery, all patients underwent complete ophthalmological examination including corneal topography, wavefront analysis for pupil diameters of 4 mm and 6 mm, and contrast sensitivity measurements with the CSV 1000E instrument under photopic and mesopic conditions with and without glare. RESULTS There was no statistically significant difference between groups in age, sex or other preoperative ocular characteristics (p > 0.05). Patients with AcrySof IQ IOLs had higher contrast sensitivity at 6 c.p.d. under photopic conditions, at 6 c.p.d. and 18 c.p.d. under mesopic conditions, and at 6 c.p.d., 12 c.p.d. and 18 c.p.d. under mesopic conditions with glare (p < 0.05). Corneal spherical aberration was 0.273 ± 0.074 μm in the AcrySof Natural group and 0.294 ± 0.086 μm in the AcrySof IQ group (p = 0489). Ocular spherical aberration was 0.362 ± 0.141 μm and 0.069 ± 0.043 μm (p < 0.001) for 6-mm diameter pupils and 0.143 ± 0.091 μm and 0.017 ± 0.016 μm (p < 0.001) for 4-mm diameter pupils, with AcrySof Natural and AcrySof IQ IOLs, respectively. There were no significant differences in other higher-order aberrations between the groups (p > 0.05). CONCLUSIONS Aspherical AcrySof IQ IOLs significantly reduced spherical aberration for pupil diameters of both 4 mm and 6 mm and also improved contrast sensitivity more than spherical AcrySof Natural IOLs, especially in mesopic conditions.
Collapse
Affiliation(s)
- Tamer Takmaz
- Second Ophthalmology Department, Atatürk Training and Research Hospital, Ankara, Turkey.
| | | | | | | |
Collapse
|
21
|
Knapp S, Awwad ST, Ghali C, McCulley JP. Ocular aberrations measured by the Fourier-based WaveScan and Zernike-based LADARWave Hartmann-Shack aberrometers. J Refract Surg 2009; 25:201-9. [PMID: 19241771 DOI: 10.3928/1081597x-20090201-05] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate agreements in lower and higher order aberration measurements by two Hartmann-Shack wavefront-sensing devices. METHODS Using the VISX WaveScan and Alcon LADARWave aberrometers, ocular aberrations at a fixed optical zone of 6 mm were measured on 36 eyes of 18 patients. A tunable light intensity source was used to control pupil size, which was checked using infrared pupillometry. Repeatability of measurements was evaluated using the intra-class correlation coefficient with 3 consecutive measurements on each aberrometer. RESULTS Mean absolute defocus for WaveScan and LADARWave was 2.82 +/- 2.69 and 2.93 +/- 3.24 root-mean-square (RMS) microm, whereas astigmatism was 0.81 +/- 0.49 and 0.87 +/- 0.57 microm, respectively. Pearson correlation coefficients between the two aberrometers were 0.908 and 0.870 for defocus and astigmatism, respectively, whereas higher order aberration correlation was less tight (Pearson correlation coefficient=0.596 for coma, 0.746 for trefoil, 0.836 for spherical aberration, 0.637 for secondary astigmatism, and 0.963 for quadra-foil [P<.001 for all]). The LADARWave had a tendency to display more spherical aberration than the WaveScan, especially at high aberration values, with mean absolute difference in measurement of 0.12 +/- 0.08 microm, and only 44% of eyes having less than +/-0.10 RMS microm of difference. The mean total higher order aberration absolute difference was 0.14 +/- 0.14 microm, with only 50% of eyes within +/-0.1 RMS of agreement. Vector analysis revealed appreciable discrepancies in third- and fourth-order directional Zemike components, while showing similar values for fifth-order components. Intra-class correlation coefficient values for both aberrometers over different aberration orders showed excellent repeatability. CONCLUSIONS The WaveScan and LADARWave share similar lower order aberration measurements, but display significantly different higher order aberration values.
Collapse
Affiliation(s)
- Stefanie Knapp
- Department of Ophthalmology, UT Southwestern Medical Center, Dallas, Texas 75390-9057, USA
| | | | | | | |
Collapse
|