Back LS, Silva J, Morsch CS, Tumedei M, Magini RDS, Piatelli A, Benfatti CAM. Clinical Performance of 170 Frictional Morse Taper Implants: 2 Years Follow-Up. J ORAL IMPLANTOL 2024; 50:127-135. [PMID: 38530824 DOI: 10.1563/aaid-joi-d-23-00054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
This study evaluated the clinical survival rates of 170 Morse taper implants through clinical and mechanical parameters in different therapeutic approaches such as single crowns, fixed partial prostheses, and fixed full-arch prostheses. Patients referred to the Center on Education and Research on Dental Implants from May 2017 to July 2018 with the indication for dental implant therapy, aged >18 years, without periodontal disease, recent evidence of inflammatory activity or other oral disorders, current pregnancy, uncontrolled diabetes mellitus or heavy smoking habit were included in this study. After 12 weeks of healing since the implants were placed in the mandible and after 16 weeks following implants placed in the maxilla, patients returned to the Center for prosthetic rehabilitation. After implant therapy, all patients underwent periodical, clinical, and prosthetic examinations every 6 months. Prosthetic restorations involved 109 fixed reconstructions in function. Few prosthetic complications were reported (6.55%). Twenty implants were rehabilitated with cemented prostheses; from those, 1 crown suffered a loss in retention/decementation. Of the 148 implants rehabilitated with screwed-retained prostheses, 6.76% suffered prosthetic screw loosening. The cumulative implant survival rate was 98.2%. When peri-implant tissue health was evaluated, the keratinized mucosa band appeared related to peri-implant tissue stability. Thus, Morse taper implants represented a successful procedure for implant rehabilitation, with a high cumulative implant survival rate, low prevalence of biological and prosthetic complications, and good stability of peri-implant tissues over the assessed period.
Collapse
Affiliation(s)
- Lara Steiner Back
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Joseane Silva
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Carolina Schäffer Morsch
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Margherita Tumedei
- Department of Biomedical, Surgical and Dental Sciences, State University of Milano, Milano, Italy and IRCCS, Fondazione Ca' Granda, IRCCS Ospedale Maggiore Policlinico, Milano, Italy
| | - Ricardo de Souza Magini
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| | - Adriano Piatelli
- School of Dentistry, Saint Camillus International University for Health Sciences (Unicamillus), Rome, Italy and Facultad de Medicina, Universidad Catolica San Antonio de Murcia, Murcia Spain
| | - Cesar Augusto Magalhães Benfatti
- Department of Dentistry, Center for Education and Research on Dental Implants (CEPID), Federal University of Santa Catarina (UFSC), Florianópolis, Brazil
| |
Collapse
|
2
|
Abayov P, Sarikov R, Nazarenko LM, Babich O, Haimov E, Juodzbalys G. Outcome Difference between Short and Longer Dental Implants Placed Simultaneously with Alveolar Bone Augmentation: a Systematic Review and Meta-Analysis. J Oral Maxillofac Res 2024; 15:e2. [PMID: 39139356 PMCID: PMC11318658 DOI: 10.5037/jomr.2024.15202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2024] [Accepted: 06/28/2024] [Indexed: 08/15/2024]
Abstract
Objectives This systematic review and meta-analysis aim to provide detailed insights into the clinical performance of short and longer dental implants placed simultaneously with bone augmentation. Material and Methods The search for literature was performed across MEDLINE (PubMed), ScienceDirect and the Cochrane Library databases, adhering to specific selection criteria and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Only articles published in English between 2014 and 2024 were considered for data collection. Primary outcomes were survival rate (SR), marginal bone loss (MBL) and complications. Clinical outcomes were as follows: bleeding on probing (BOP), periodontal pocket depth (PPD), and implant stability quotient (ISQ). Quality and risk of bias assessment were evaluated by the Critical Appraisal Checklist tool for randomized controlled trials developed by the Joanna Briggs Institute. Results A total of 14678 articles were screened, with 9 meeting the inclusion criteria and being utilized for this systematic review and meta-analysis. A total of 495 patients with 984 implants (491 short and 493 longer implants) showing a SR of 93.91% for the short implants and 91.83% for the longer implants. Meta-analysis revealed statistically significant difference between short implants and longer implants simultaneously placed with alveolar bone augmentation in relation to MBL (-0.513 mm, 95% CI = -0.93 to -0.096; P = 0.02), and in PPD (-0.247, 95% CI = -0.515 to 0.022; P = 0.07). Conclusions When comparing the results of treatment with short and longer dental implants combined with alveolar bone augmentation, short implants showed better clinical results regarding the parameters of survival rate, marginal bone loss and complications.
Collapse
Affiliation(s)
- Pinny Abayov
- Department of Maxillofacial Surgery, Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Rafael Sarikov
- Oral and maxillofacial rehabilitation department and the temporomandibular joint diseases unit, Rambam Medical Center, HaifaIsrael.
| | - Lisa-Marie Nazarenko
- Department of Maxillofacial Surgery, Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Oren Babich
- Department of Maxillofacial Surgery, Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Eliezer Haimov
- Department of Maxillofacial Surgery, Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| | - Gintaras Juodzbalys
- Department of Maxillofacial Surgery, Faculty of Odontology, Medical Academy, Lithuanian University of Health Sciences, KaunasLithuania.
| |
Collapse
|
3
|
Verma V, Hazari P, Verma P. Biomechanical efficiency of different implant-abutment connection: a systematic review of studies using photoelastic stress analysis. Evid Based Dent 2023; 24:92. [PMID: 37188921 DOI: 10.1038/s41432-023-00884-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
Abstract
PURPOSE The present review aimed to comparatively evaluate the biomechanical efficiency of different implant-abutment connections studied by photoelastic stress analysis. MATERIALS AND METHODS A comprehensive online literature search was conducted on Medline (Pubmed), Web of Science, and Google Scholar from 2000(Jan) to 2023(Jan). Keywords used initially to carry out the search included implant-abutment connection & photoelastic stress analysis, and stress distribution in different implant-abutment connections. 34 photoelastic stress analysis studies were screened and 30 studies were excluded after the screening of the title, abstract and full article. Finally, 4 studies were included for complete review. RESULT The result of this systematic review showed that the internal connection was more efficient then the external connection as there was less marginal bone loss and favorable distribution of stress in internal connection. CONCLUSION Crestal bone loss is more in external connection when compared to internal connection. In Internal connection, there is more intimate contact between the abutment's outer surface and implant which renders a more stable interface, which favoring uniform stress distribution and protects the retention screw.
Collapse
Affiliation(s)
- Varsha Verma
- Department of Prosthodontics and Crown & Bridge, People's Dental Academy, Bhopal, Madhya Pradesh, India.
| | - Puja Hazari
- Department of Prosthodontics and Crown & Bridge, Peoples Dental Academy, Bhopal, Madhya Pradesh, India
| | - Puja Verma
- School of Humanities and Engineering Sciences, MIT Academy of Engineering, Alandi, Pune, Maharashtra, India
| |
Collapse
|
4
|
Zhang WT, Cheng KJ, Liu YF, Wang R, Chen YF, Ding YD, Yang F, Wang LH. Effect of the prosthetic index on stress distribution in Morse taper connection implant system and peri-implant bone: a 3D finite element analysis. BMC Oral Health 2022; 22:431. [PMID: 36180871 PMCID: PMC9523891 DOI: 10.1186/s12903-022-02465-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 09/19/2022] [Indexed: 11/23/2022] Open
Abstract
Background The combination of a prosthetic index with Morse taper connection was developed, with the purpose of making prosthetic procedures more precise. However, the presence of the index may compromise the mechanical performance of the abutment. The aim of this study is to evaluate the effect of prosthetic index on stress distribution in implant–abutment-screw system and peri-implant bone by using the 3D finite element methodology. Methods Two commercial dental implant systems with different implant–abutment connections were used: the Morse taper connection with platform switching (MT-PS) implant system and the internal hex connection with platform matching (IH-PM) implant system. Meanwhile, there are two different designs of Morse taper connection abutment, namely, abutments with or without index. Consequently, three different models were developed and evaluated: (1) MT-PS indexed, (2) MT-PS non-indexed, and (3) IH-PM. These models were inserted into a bone block. Vertical and oblique forces of 100 N were applied to each abutment to simulate occlusal loadings. Results For the MT-PS implant system, the maximum stress was always concentrated in the abutment neck under both vertical and oblique loading. Moreover, the maximum von Mises stress in the neck of the MT-PS abutment with index even exceed the yield strength of titanium alloy under the oblique loading. For the IH-PM implant system, however, the maximum stress was always located at the implant. Additionally, the MT-PS implant system has a significantly higher stress level in the abutment neck and a lower stress level around the peri-implant bone compared to the IH-PM implant system. The combined average maximum stress from vertical and oblique loads is 2.04 times higher in the MT-PS indexed model, and 1.82 times for the MT-PS non-indexed model than that of the IH-PM model. Conclusions MT-PS with index will cause higher stress concentration on the abutment neck than that of without index, which is more prone to mechanical complications. Nevertheless, MT-PS decreases stress within cancellous bone and may contribute to limiting crestal bone resorption.
Collapse
Affiliation(s)
- Wen-Tao Zhang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Kang-Jie Cheng
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, 310023, China.,National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Yun-Feng Liu
- College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, 310023, China.,Key Laboratory of Special Purpose Equipment and Advanced Processing Technology, Ministry of Education and Zhejiang Province, Zhejiang University of Technology, Hangzhou, 310023, China.,National International Joint Research Center of Special Purpose Equipment and Advanced Processing Technology, Zhejiang University of Technology, Hangzhou, 310023, China
| | - Russell Wang
- Department of Comprehensive Care, Case Western Reserve University School of Dental Medicine, Cleveland, OH, 44106-4905, USA
| | - Yun-Fang Chen
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Yu-de Ding
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China
| | - Fan Yang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China.
| | - Lin-Hong Wang
- Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), No. 158 Shangtang Rd., Hangzhou, 310014, China.
| |
Collapse
|
5
|
de Carvalho Formiga M, Grzech-Leśniak K, Moraschini V, Shibli JA, Neiva R. Effects of Osseodensification on Immediate Implant Placement: Retrospective Analysis of 211 Implants. MATERIALS 2022; 15:ma15103539. [PMID: 35629566 PMCID: PMC9147081 DOI: 10.3390/ma15103539] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/07/2022] [Accepted: 05/12/2022] [Indexed: 01/14/2023]
Abstract
Osseodensification is a new method of bone instrumentation for dental implant placement that preserves bulk bone and increases primary implant stability, and may accelerate the implant rehabilitation treatment period and provide higher success and survival rates than conventional methods. The aim of this retrospective study was to evaluate and discuss results obtained on immediate implant placement with immediate and delayed loading protocols under Osseodensification bone instrumentation. This study included private practice patients that required dental implant rehabilitation, between February 2017 and October 2019. All implants were placed under Osseodensification and had to be in function for at least 12 months to be included on the study. A total of 211 implants were included in the study, with a 98.1% total survival rate (97.9% in the maxilla and 98.5% in the mandible). For immediate implants with immediate load, 99.2% survival rate was achieved, and 100% survival rate for immediate implant placement without immediate load cases. A total of four implants were lost during this period, and all of them were lost within two months after placement. Within the limitations of this study, it can be concluded that Osseodensification bone instrumentation provided similar or better results on survival rates than conventional bone instrumentation.
Collapse
Affiliation(s)
| | - Kinga Grzech-Leśniak
- Laser Laboratory Oral Surgery Department, Medical University of Wroclaw, 50-425 Wroclaw, Poland;
| | - Vittorio Moraschini
- Department of Periodontology, Veiga de Almeida University, Rio de Janeiro 20271-020, Brazil;
| | - Jamil Awad Shibli
- Department of Periodontology and Oral Implantology, Dental Research Division, University of Guarulhos, Guarulhos 07023-040, Brazil
- Correspondence:
| | - Rodrigo Neiva
- Department of Periodontics, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA;
| |
Collapse
|
6
|
In Vitro Study of Preload Loss in Different Implant Abutment Connection Designs. MATERIALS 2022; 15:ma15041392. [PMID: 35207933 PMCID: PMC8879145 DOI: 10.3390/ma15041392] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 02/02/2022] [Accepted: 02/10/2022] [Indexed: 02/04/2023]
Abstract
The stability and integrity of the abutment-implant connection, by means of a screw, is fallible from the moment the prosthetic elements are joined and is dependent on the applied preload, wear of the components and function. One of the main causes of screw loosening is the loss of preload. The loosening of the screw-abutment can cause complications such as screw fracture, marginal gap, peri-implantitis, bacterial microleakage, loosening of the crown and discomfort of the patient. It is also reported that loosening of the screw/abutment may lead to a failure of osseointegration. It is necessary to evaluate and quantify, with in vitro studies, the torque loss before and after loading in the different connections. Aim: evaluate the influence of implant- abutment connection design in torque maintenance after single tightening, multiple tightening and multiple tightening followed by mechanical cycling. Materials and Methods: 180 Klockner implants divided in 4 groups: 15 SK2 external connection, 25 Ncm tightening torque; 15 KL external connection, 30 Ncm tightening torque; 15 Vega internal connection, 25 Ncm tightening torque; 15 Essential internal connection, 30 Ncm tightening torque. In each group removal torque values (RTV) were evaluated with a digital torque meter, in 3 distinct phases: after one single tightening, 10 multiple tightenings and 10 multiple tightenings and cyclic loading (500 N × 1000 cycles). Results: After one single tightening, and for all connections, RTV were lower than those of insertion, but only for Essential and Vega internal connections this result was statistically significant. After multiple tightening, RTV were significantly lower in all connections. After repeated tightening followed by cyclic loading, mean RTV were significantly lower, when compared to insertion torque. The multiple tightening technique resulted in higher RTV than the single tightening technique, except for Vega implant. The multiple tightening followed by cyclic load, compared to the other phases, was the one that generated the lowest RTV, for all connections. Conclusions: The connection design, in our study, did not seem to influence the maintenance of preload. Loading influenced the loss of preload, in the sense that significantly decreased the removal torque values. The multiple re-tightening technique resulted in higher removal torque values than the single tightening technique. Clinically, our results recommend to retighten retaining screws, a few minutes after insertion.
Collapse
|
7
|
de Aguiar Vilela Júnior R, Aranha LC, Elias CN, Martinez EF. In vitro analysis of prosthetic abutment and angulable frictional implant interface adaptation: Mechanical and microbiological study. J Biomech 2021; 128:110733. [PMID: 34530293 DOI: 10.1016/j.jbiomech.2021.110733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 08/30/2021] [Accepted: 09/01/2021] [Indexed: 10/20/2022]
Abstract
The aim of this study was to evaluate, in vitro, the microbiological sealing at the implant and different angles frictional prosthetic abutment interface, submitted or not to mechanical cycling, as well as the deactivation force and evaluation of the implant-abutment interface by scanning electron microscopy. For this study, the sealing capacity of eighty sets of abutments/implants of each angle, with and without mechanical cycling, with internal conical connection (locking tapper) (4.3 mm × 9.0 mm) constituted in Titanium alloy (Ti6Al4V), and stainless steel angled prosthetic abutment was evaluated (18Cr14Ni2.5Mo) according to ASTM F138-13a (Arcsys, FGM, Joinville, Brazil), 6 mm high and 4.2 mm in diameter at the coronary portion, and 3.5 mm high transmucosal, in 4 different angles (0, 5, 10 and 20°). After in vitro tests, 100% biological sealing was observed at the implant / prosthetic abutment interface within cycled and non-cycled conditions, for the straight, 5, 10 and 20° inclination groups. There was no statistically significant difference in the removal force of the prosthetic abutments at different angles, under non-cycled conditions; however, under mechanical loading, the deactivation force was significantly higher for straight prosthetic abutments than with 10 and 20° of angulation. Surface analysis revealed good adaptation between implants and abutments, and the presence of wear areas, independently of mechanical loading. It is concluded that the analysis of implant and prosthetic abutment interface revealed good adaptation between the parts, for all analyzed samples.
Collapse
Affiliation(s)
| | - Luís Cláudio Aranha
- Materials Science and Technology Center, Nuclear and Energy Research Institute (IPEN), SP, Brazil
| | - Carlos Nelson Elias
- Department of Materials Science, Military Institute of Engineering (IME), Rio de Janeiro, RJ, Brazil
| | | |
Collapse
|
8
|
Montero J. A Review of the Major Prosthetic Factors Influencing the Prognosis of Implant Prosthodontics. J Clin Med 2021; 10:jcm10040816. [PMID: 33671394 PMCID: PMC7921991 DOI: 10.3390/jcm10040816] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2020] [Revised: 01/28/2021] [Accepted: 02/15/2021] [Indexed: 11/16/2022] Open
Abstract
Background: The treatment plan of prosthetic restorations supported by dental implants requires comprehensive scientific knowledge to deliver prostheses with good prognosis, even before the implant insertion. This review aims to analyze the main prosthetic determinants of the prognosis of implant-supported prostheses. Methods: A comprehensive review of the literature was conducted with a PICO (Patient Intervention Comparison Outcomes) question: “For partially or complete edentulous subjects treated with implant-supported prostheses, which prosthetic factors could affect clinical outcomes?”. A literature search was performed electronically in PubMed (MEDLINE), Scopus and Cochrane Library with the following equation [PROGNOS * OR RISK] FACTOR IMPLANT DENTAL, and by hand search in relevant journals and throughout the selected papers. Results: This revision was carried out based on 50 papers focused on several prosthodontics-related risk factors that were grouped as follows: implant-connection, loading protocol, transmucosal abutments, prosthetic fit, provisionalization, type of retention, impression technique, fabrication technique, and occlusion. More than a half of the studies were systematic reviews (30%), meta-analysis (16%), or prospective evaluations of prosthesis with various kinds of events (18%). However, narrative reviews of literature (14%) and in vitro/animal studies (16%) were also found. Conclusions: The current literature provides insufficient evidence for most of the investigated topics. However, based on the accumulated data, it seems reasonable to defend that the best treatment approach is the use of morse taper implants with transmucosal abutments, recorded by means of rigidly splinted copings through the pick-up technique, and screwed by milled prosthesis occlusally adjusted to minimize functional overloading.
Collapse
Affiliation(s)
- Javier Montero
- Department of Surgery, University of Salamanca, 37007 Salamanca, Spain
| |
Collapse
|
9
|
Romanos GE, Delgado-Ruiz RA, Nicolas-Silvente AI. Volumetric Changes in Morse Taper Connections After Implant Placement in Dense Bone. In-Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2020; 13:ma13102306. [PMID: 32429470 PMCID: PMC7287620 DOI: 10.3390/ma13102306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 05/12/2020] [Accepted: 05/13/2020] [Indexed: 06/11/2023]
Abstract
The stability of the implant-abutment interface is crucial for the maintenance of the implant index integrity. Several factors are capable of inducing deformation in implant-abutment connection, such as the actual insertion of the implant into the bone. This study aimed to evaluate the deformations produced in the connection after the insertion of the implant. Ten implants with two different implant carriers (Type A: carrier attached to platform and Type B: carrier attached inside the index-connection) were placed in artificial Type II bone, and volumetric changes were evaluated for different connection features with a 3D digital microscope. ANOVA (analysis of variance), Wilcoxon, and Tukey HSD post-test were used for statistical comparisons. Type A implants presented deformation at the platform level (inner slot angles and slot width), but no volumetric changes were observed inside the connection. Type B implants presented deformation in three parameters inside the connection (outer channel length, coronal step width, and coronal step length). Within the limitations of this study, we can conclude that more deformation is expected at the internal connection when the implant carrier engages this area. The engagement area should be as far away as possible from the index connection.
Collapse
Affiliation(s)
- Georgios E. Romanos
- Periodontology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794-8712, USA
| | - Rafael Arcesio Delgado-Ruiz
- Prosthodontics and Digital Technology, School of Dental Medicine, Stony Brook University, Stony Brook, NY 11794-8712, USA;
| | | |
Collapse
|
10
|
Caetano GM, Pauletto P, Mezzomo LA, Rivaldo EG. Crestal Bone Changes in Different Implants Designs: A Prospective Clinical Trial. Eur J Dent 2020; 13:497-502. [PMID: 31891966 PMCID: PMC6938439 DOI: 10.1055/s-0039-1697216] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Objective
Several modifications, such as changes in the implant–abutment connection, have been suggested in studies on dental implants to better preserve the peri-implant bone level. The aim of this study was to prospectively compare crestal bone level changes between two different implant designs—tissue level (TL) and bone level (BL).
Materials and Methods
The sample comprised 18 patients, on whom a total of 30 hydrophilic tissue- and bone level implants were placed (SLActive, Straumann Institut AG, Basel, Switzerland), in the posterior region of the maxilla or the mandible. Impressions were taken after 45 days of healing. Then, cemented-retained metalloceramic crowns were fabricated and installed. Marginal bone level changes were assessed by the paralleling technique of periapical radiographies, on both mesial and distal aspects of each implant, at the moment of the implant placement and after 1 year of loading. Photoshop software was used to perform linear measurements by a single and calibrated examiner.
Statistical Analysis
The Mann–Whitney test at a 5% significance level was used to compare the bone changes among the implants assessed.
Results
A significantly lower (
p
= 0.048) bone remodeling was observed on bone level implants (0.05 mm), when compared to tissue level implants (0.47 mm;
p
= 0.048). The average marginal bone level changes at the distal aspect did not show any statistically significant difference (
p
= 0.325).
Conclusions
Tissue level implants presented greater bone loss in the mesial surface than bone level implants. Both designs presented stable and clinically acceptable bone crests.
Collapse
Affiliation(s)
- Gustavo M Caetano
- Department of Dentistry, Lutheran University of Brazil, Canoas-RS, Brazil
| | - Patrícia Pauletto
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis-SC, Brazil
| | - Luis A Mezzomo
- Department of Dentistry, Federal University of Santa Catarina, Florianópolis-SC, Brazil
| | - Elken G Rivaldo
- Department of Dentistry, Lutheran University of Brazil, Canoas-RS, Brazil
| |
Collapse
|
11
|
Khalaila W, Nasser M, Ormianer Z. Evaluation of the relationship between Periotest values, marginal bone loss, and stability of single dental implants: A 3-year prospective study. J Prosthet Dent 2019; 124:183-188. [PMID: 31780107 DOI: 10.1016/j.prosdent.2019.08.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 08/28/2019] [Accepted: 08/28/2019] [Indexed: 10/25/2022]
Abstract
STATEMENT OF PROBLEM Although the Periotest has been shown to provide reliable information about initial implant stability, whether Periotest values (PTVs) can be correlated with the stability of implants in function for several years is unclear. PURPOSE The purpose of this prospective clinical study was to investigate implant stability by using PTVs, as well as changes in stability and peri-implant marginal bone levels (as measured by radiographs) over a 3-year follow-up period. The exploratory hypothesis was that there is a significant correlation between PTVs and bone loss around the implant and that PTVs can provide predictive information about marginal bone-level changes and implant stability over time. MATERIAL AND METHODS The study population included patients who needed single-tooth replacement with restoration of cemented fixed partial dentures. Clinical data, PTVs, and periapical radiographs were collected at the time points of implant placement, 3 to 6 months after insertion, and 1 year, 2 years, and 3 years after the final definitive prosthetic restoration. Pearson correlation coefficient tests were performed to estimate the correlation between the PTVs received at the first follow-up time point and the subsequent PTVs received during the follow-up period (up to 3 years after the restoration). The Pearson test was applied, as well as the t test and repeated-measures ANOVA, to evaluate PTVs and bone loss changes over time. The Pearson test was also applied to estimate the correlation between the bone loss values measured at the first follow-up visit and the subsequent bone loss values at the annual follow-up time points (up to and including 3 years after the restoration). RESULTS A total of 43 implants were inserted in 34 patients (26 men and 8 women); the average patient age was 52.8 years. A significant reduction in implant stability was detected between implant insertion and the 3- to 6-month follow-up time point, which was then followed by a significant increase in stability at the 1-year follow-up time point and then stabilized during the 2- and 3-year follow-up time points (P<.014). Furthermore, a significant correlation was found between PTVs at the 1-year follow-up and the PTVs at all measured follow-up time points (P<.05). A positive correlation was obtained with high-strength correlation coefficient R (R>0.7) at all follow-up time points. Bone loss changes during the follow-up time points were significantly different and correlated with PTVs (P<.001). CONCLUSIONS The Periotest is a reliable device for assessing implant stability and providing predictive information about marginal bone level changes around an implant.
Collapse
Affiliation(s)
- Waseem Khalaila
- Graduate student, Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Minaem Nasser
- Graduate student, Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Zeev Ormianer
- Senior Lecturer, Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
| |
Collapse
|
12
|
Yao KT, Chang TY, Fang HW, Huang CH, Wang DH, Hsu ML. Abutment screw withdrawal after conical abutment settlement: A pilot study. Clin Oral Implants Res 2019; 31:144-152. [PMID: 31647133 DOI: 10.1111/clr.13550] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 10/11/2019] [Accepted: 10/19/2019] [Indexed: 12/01/2022]
Abstract
OBJECTIVE This study investigated the effects of abutment screw withdrawal after conical abutment settlement on the stability of the implant-abutment connection. MATERIALS AND METHODS Twenty implants of a conical connection system were used. Two two-piece abutment designs were used: cone only (n = 10; NI) and cone plus octagonal index design (n = 10; I); for each design, five samples were used with (S) and without (NS) abutment screw withdrawal before a cyclic test. Finally, four groups, namely Gr S(NI), Gr S(I), Gr NS(NI), and Gr NS(I), were included. The cyclic test included cyclic loading of 20-200 N, 30°, and 4-mm off-axis to implant axis at 10 Hz for 106 cycles, simulating a clinical time interval of 40 months. The fatigue cycles were recorded. The axial displacement of the conical abutments during abutment settlement, screw withdrawal, and cyclic loading were measured. Abutment morphology was examined through scanning electron microscopy (SEM). RESULTS Only Gr NS(NI) failed the test, indicating that without the index design and abutment screw withdrawal, and connection stability seriously deteriorated. Gr NS(I) exhibited significantly higher axial displacement into the implant after abutment settlement than did Gr NS(NI). It also exhibited continuous axial displacement into the implant after cyclic loading. SEM after cyclic testing in Gr NS(I) revealed marked burnishing on lateral edges of the index, indicating that the index design provides an antitorsional ability. CONCLUSION Although this study has few limitations, abutment screw withdrawal is feasible in this conical implant-abutment connection system with index design.
Collapse
Affiliation(s)
- Kuang-Ta Yao
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Tsai-Yu Chang
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Hsu-Wei Fang
- Department of Chemical Engineering and Biotechnology & Institute of Chemical Engineering, National Taipei University of Technology, Taipei, Taiwan.,Division of Medical Engineering Research, National Health Research Institutes, Miaoli, Taiwan
| | - Chang-Hung Huang
- Department of Medical Research, Mackay Memorial Hospital, New Taipei city, Taiwan
| | - Ding-Han Wang
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| | - Ming-Lun Hsu
- School of Dentistry, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
13
|
de Avila ED, van Oirschot BA, van den Beucken JJJP. Biomaterial-based possibilities for managing peri-implantitis. J Periodontal Res 2019; 55:165-173. [PMID: 31638267 PMCID: PMC7154698 DOI: 10.1111/jre.12707] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 08/22/2019] [Accepted: 09/18/2019] [Indexed: 12/13/2022]
Abstract
Peri‐implantitis is an inflammatory disease of hard and soft tissues around osseointegrated implants, followed by a progressive damage of alveolar bone. Oral microorganisms can adhere to all types of surfaces by the production of multiple adhesive factors. Inherent properties of materials will influence not only the number of microorganisms, but also their profile and adhesion force onto the material surface. In this perspective, strategies to reduce the adhesion of pathogenic microorganisms on dental implants and their components should be investigated in modern rehabilitation concepts in implant dentistry. To date, several metallic nanoparticle films have been developed to reduce the growth of pathogenic bacteria. However, the main drawback in these approaches is the potential toxicity and accumulative effect of the metals over time. In view of biological issues and in attempt to prevent and/or treat peri‐implantitis, biomaterials as carriers of antimicrobial substances have attracted special attention for application as coatings on dental implant devices. This review will focus on biomaterial‐based possibilities to prevent and/or treat peri‐implantitis by describing concepts and dental implant components suitable for engagement in preventing and treating this disease. Additionally, we raise important criteria referring to the geometric parameters of dental implants and their components, which can directly affect peri‐implant tissue conditions. Finally, we overview currently available biomaterial systems that can be used in the field of oral implantology.
Collapse
Affiliation(s)
- Erica D de Avila
- Regenerative Biomaterials, Radboudumc, Nijmegen, The Netherlands.,Department of Dental Materials and Prosthodontics, School of Dentistry at Araraquara, Sao Paulo State University-UNESP, Araraquara, São Paulo, Brazil
| | - Bart A van Oirschot
- Regenerative Biomaterials, Radboudumc, Nijmegen, The Netherlands.,Department of Implantology & Periodontology, Radboudumc, Nijmegen, The Netherlands
| | | |
Collapse
|
14
|
MACHADO RCM, THOMÉ G, BERNARDES SR, MELO ACM. Morse taper implant macrodesign, loading protocol and site of installation – retrospective study of 5,601 implants. REVISTA DE ODONTOLOGIA DA UNESP 2019. [DOI: 10.1590/1807-2577.06919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Abstract Introduction The long-term implant-supported prosthetic rehabilitation monitoring is extremely important in evaluating parameters that could interfere in the success of the treatment. Objective To evaluate the influence of macrodesign (shape of the body and apex), length and diameter, insertion torque, site of installation as well as the loading protocol, on long-term survival rates. Material and method The data obtained was from the medical records of rehabilitated patients who had had at least one Morse taper implant surgery done at ILAPEO School between 2006 -2012. Incomplete medical records, from which it would have been impossible to extract all data essential to complete the study, were excluded. Result A total of 1,142 patient’s medical records comprised the sample; documenting the progress of 5,601 implants, done in both jaws and mandibles. The final survival rate was 98.31%, over an average time of 37.54 months. The type of implant most used was cylindrical (70.33%). The mean installation torque most evidenced in the study was between 41 and 50 Ncm. A logistical regression analysis showed that none of the following variables, site of installation, body and apex shape designs and length, had any significant statistical influence on implant loss. Torque increase and diameter influenced implant loss while immediate loading favored implant maintenance. Conclusion It can be concluded that Morse taper implants present a long-term survival rate that can be lowered by excessive torque, as well as by the diameter of the implant.
Collapse
Affiliation(s)
| | - Geninho THOMÉ
- Instituto Latino Americano de Pesquisa e Ensino Odontológico, Brasil
| | | | | |
Collapse
|
15
|
Splinted and Nonsplinted Crowns with Different Implant Lengths in the Posterior Maxilla by Three-Dimensional Finite Element Analysis. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:3163096. [PMID: 30254726 PMCID: PMC6140271 DOI: 10.1155/2018/3163096] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Accepted: 07/30/2018] [Indexed: 02/06/2023]
Abstract
The aim of this study was to evaluate stress distribution in the implants/components and bone tissue for splinted and nonsplinted prostheses with different lengths of implants using three-dimensional finite element analysis. Six models from the posterior maxillary area were used in simulations. Each model simulated three Morse taper implants of 4.0 mm diameter with different lengths, which supported metal-ceramic crowns. An axial load of 400 N and an oblique load of 200 N were used as loading conditions. Splinted prostheses exhibited better stress distribution for the implants/components, whereas nonsplinted prostheses exhibited higher stress in the first molar under axial/oblique loading. Implant length did not influence stress distribution in the implants/components. In cortical bone tissue, splinted prostheses decreased the tensile stress in the first molar, whereas nonsplinted prostheses were subjected to higher tensile stress in the first molar; implant length had no influence on stress distribution. Within the limitations of this study, we conclude that splinted prostheses contributed to better stress distribution in the implant/abutment and cortical bone tissue; however, the reduction in the implant length did not influence the stress distribution.
Collapse
|
16
|
Wong CKK, Narvekar U, Petridis H. Prosthodontic Complications of Metal-Ceramic and All-Ceramic, Complete-Arch Fixed Implant Prostheses with Minimum 5 Years Mean Follow-Up Period. A Systematic Review and Meta-Analysis. J Prosthodont 2018; 28:e722-e735. [DOI: 10.1111/jopr.12797] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/21/2018] [Indexed: 10/17/2022] Open
|
17
|
Schoenbaum TR, Chang YY, Stevenson RG. Screw Access Mark for Cemented Implant Crowns: A Universal Technique to Simplify Retrievability. J ORAL IMPLANTOL 2018; 44:71-73. [DOI: 10.1563/aaid-joi-d-17-00147] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The use of cemented implant prostheses for partially edentulous patients continues to increase in clinical practice. One of the primary complications of the cemented implant crown is difficulty in retrieval, should the need arise. Drilling through most prosthetic materials is of little difficulty for most clinicians, but the complication lies in determining where exactly the access hole needs to be drilled. During fabrication, the location of the screw access channel is marked with a strong contrasting color stain on the surface of the prosthesis. The technique proposed here marks the location of the screw access directly on the prosthesis, thus improving the ease and predictability of future retrieval.
Collapse
Affiliation(s)
- Todd R. Schoenbaum
- Division of Constitutive and Regenerative Sciences, University of California-Los Angeles School of Dentistry, Los Angeles, Calif
| | | | - Richard G. Stevenson
- Division of Constitutive and Regenerative Sciences, University of California-Los Angeles School of Dentistry, Los Angeles, Calif
| |
Collapse
|
18
|
Abstract
PURPOSE To evaluate the effect of blasting and bonding on abutment surface to prevent screw loosening in Morse taper connections. MATERIAL AND METHODS Twenty-eight Morse taper connection implants were divided into 4 groups: no treatment (G1), blasting (G2), bonding (G3), and blasting + bonding (G4). In groups G2 and G4, the abutments were blasted with aluminum oxide granules; in groups G3 and G4, the conical abutment region was covered with a thin layer of bond thread lock agent. In all implants, the abutment-implant joint was tightened at a torque of 35 Ncm. The specimens were submitted to the mechanical cycling, under an oblique load for 1.0 × 10 cycles. The torque was measured with a digital torque meter. Data were analyzed by the t test, one-way analysis of variance, and Tukey tests (95%). RESULTS The loosening strength was significantly higher in group G4 (35.83 ± 3.02 Ncm). There was no significant difference among groups G1 (25.86 ± 1.96 Ncm), G2 (25.86 ± 3.29 Ncm), and G3 (26.14 ± 2.12 Ncm). CONCLUSION The association of blasting and bonding on abutment surface can be used to prevent screw loosening in Morse taper implants.
Collapse
|
19
|
Liu Y, Wang J. Influences of microgap and micromotion of implant-abutment interface on marginal bone loss around implant neck. Arch Oral Biol 2017; 83:153-160. [PMID: 28780384 DOI: 10.1016/j.archoralbio.2017.07.022] [Citation(s) in RCA: 80] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2017] [Revised: 07/19/2017] [Accepted: 07/27/2017] [Indexed: 01/14/2023]
Abstract
OBJECTIVE To review the influences and clinical implications of micro-gap and micro-motion of implant-abutment interface on marginal bone loss around the neck of implant. DESIGN Literatures were searched based on the following Keywords: implant-abutment interface/implant-abutment connection/implant-abutment conjunction, microgap, micromotion/micromovement, microleakage, and current control methods available. The papers were then screened through titles, abstracts, and full texts. RESULTS A total of 83 studies were included in the literature review. Two-piece implant systems are widely used in clinics. However, the production error and masticatory load result in the presence of microgap and micromotion between the implant and the abutment, which directly or indirectly causes microleakage and mechanical damage. Consequently, the degrees of microgap and micromotion further increase, and marginal bone absorption finally occurs. We summarize the influences of microgap and micromotion at the implant-abutment interface on marginal bone loss around the neck of the implant. We also recommend some feasible methods to reduce their effect. CONCLUSIONS Clinicians and patients should pay more attention to the mechanisms as well as the control methods of microgap and micromotion. To reduce the corresponding detriment to the implant marginal bone, suitable Morse taper or hybrid connection implants and platform switching abutments should be selected, as well as other potential methods.
Collapse
Affiliation(s)
- Yang Liu
- Department of Prosthodontics, School of Stomatology, Wuhan University, Wuhan, 430079, China.
| | - Jiawei Wang
- Department of Prosthodontics, School of Stomatology, Wuhan University, Wuhan, 430079, China.
| |
Collapse
|
20
|
Marginal bone loss around non-submerged implants is associated with salivary microbiome during bone healing. Int J Oral Sci 2017. [PMID: 28621324 PMCID: PMC5518974 DOI: 10.1038/ijos.2017.18] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Marginal bone loss during bone healing exists around non-submerged dental implants. The aim of this study was to identify the relationship between different degrees of marginal bone loss during bone healing and the salivary microbiome. One hundred patients were recruited, and marginal bone loss around their implants was measured using cone beam computed tomography during a 3-month healing period. The patients were divided into three groups according to the severity of marginal bone loss. Saliva samples were collected from all subjected and were analysed using 16S MiSeq sequencing. Although the overall structure of the microbial community was not dramatically altered, the relative abundance of several taxonomic groups noticeably changed. The abundance of species in the phyla Spirochaeta and Synergistetes increased significantly as the bone loss became more severe. Species within the genus Treponema also exhibited increased abundance, whereas Veillonella, Haemophilus and Leptotrichia exhibited reduced abundances, in groups with more bone loss. Porphyromonasgingivalis, Treponemadenticola and Streptococcus intermedius were significantly more abundant in the moderate group and/or severe group. The severity of marginal bone loss around the non-submerged implant was associated with dissimilar taxonomic compositions. An increased severity of marginal bone loss was related to increased proportions of periodontal pathogenic species. These data suggest a potential role of microbes in the progression of marginal bone loss during bone healing.
Collapse
|
21
|
Ye L. [Current dental implant design and its clinical importance]. HUA XI KOU QIANG YI XUE ZA ZHI = HUAXI KOUQIANG YIXUE ZAZHI = WEST CHINA JOURNAL OF STOMATOLOGY 2017; 35:18-28. [PMID: 28326723 DOI: 10.7518/hxkq.2017.01.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The development of clinical implant dentistry was intensively affected by dental implant design improvement and innovation, which brought about new concept, even milestone-like changes of clinical protocol. The current improvements of dental implant design and their clinical importance could be highlighted as followings: 1) The implant apical design influences the implant preliminary stability in immediate implant. The apical 3-5 mm design of implant makes implant stable in immediate implant, because this part would be screwed into alveolar bone through fresh socket, the other part of implant could not be tightly screwed in the socket because of smaller implant diameter. Implant apical form, screw design, self-taping of apical part would be essential for immediate implant. 2) The enough preliminary stability of implant makes immediate prosthesis possible. When osseointegration does not occur, the implant stability comes from a mechanical anchorage, which depends on implant form, screw thread and self-taping design. 3) Implant neck design may have influence for soft tissue recession in esthetic zone. The implant with large shoulder would not be selected for the esthetic area. The platform design may be more favorable in the area. 4) The connection design between implant and abutment is thought a very important structure in implant long-term stability. Moose taper and "tube in tube" were well documented structure design in 20-year clinical practice in Peking University. 5) In last 15 years, the plenty studies showed the platform design of implant had positive influence in implant marginal bone level. Whatever in single implant restoration or multi-implant prosthesis. 6) The digital technology makes clinical work more precise and high-tech. This would be a trend in implant dentistry. New generation of chair-side digital computer-aided design/computer-aided manufacturing makes immediate prosthesis without conventional impression possible. 7) New abutment design have changed clinical protocol greatly. The All-on-four concept and Weldone concept benefit both from the abutment innovation, which were large angulated abutment and special welding abutment materials.
Collapse
Affiliation(s)
- Lin Ye
- Dept. of Oral Implant, School and Hospital of Stomatology, Peking University, Beijing 100081, China
| |
Collapse
|
22
|
Teixeira ABV, Shimano AC, Macedo AP, Valente MLC, dos Reis AC. Influence of torsional strength on different types of dental implant platforms. IMPLANT DENT 2017; 24:281-6. [PMID: 25961168 DOI: 10.1097/id.0000000000000247] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
AIM The study assessed deformation of implant components submitted to torsion tests of 80 and 120 N · cm using an optical stereomicroscope. MATERIAL AND METHODS The following 3 types of Titaniumfix conical implant connections (n = 5) measuring Ø 4.0 × 11.5 mm were used: external, internal hexagon and Morse taper connections. The diagonal and lateral measurements of the hexagon implant platform were measured before and after the torsion test. RESULTS The torsion test using torque of 80 and 120 N · cm altered the implant dental platforms. All groups presented deformation of implant component after torque of 80 N · cm with no statistical difference among them. During torque of 120 N · cm, a difference in the Morse taper connection in relation to the internal and external hexagon connection was observed. The Morse taper connection implant, followed by the internal hex implant, underwent less deformation. Greater deformation occurred in the external hex implants. CONCLUSION For all the implants, high insertion torques deformed the implant platform preventing long-term maintenance and stability of implants.
Collapse
Affiliation(s)
- Ana Beatriz V Teixeira
- *Postgraduate Student, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. †Associate Professor, Department of Biomechanics, Medicine and Rehabilitation of the Locomotor System, Medicine School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. ‡Research Laboratory Specialist, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. §Postgraduate Student, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil. ‖Titular Professor, Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil
| | | | | | | | | |
Collapse
|
23
|
Bordin D, Witek L, Fardin VP, Bonfante EA, Coelho PG. Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs. J Prosthodont 2016; 27:659-664. [PMID: 27859976 DOI: 10.1111/jopr.12540] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/27/2016] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To evaluate the reliability of narrow diameter dental implants (NDIs) with similar macrogeometry and 3 implant-abutment connection designs. MATERIALS AND METHODS Eighty-four NDIs (3.5 × 10 mm) were selected and divided into 4 groups (n = 21/group) according to implant-abutment connection design, as follows: EH - external hexagon, IH - internal hexagon, IC - internal conical, and IC-M - internal conical connected to a monolithic titanium abutment. Identical abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. Use of level probability Weibull curves, and reliability for a mission of 50,000 cycles at 75 N and 200 N were calculated. RESULTS The beta (β) values were: 1.48 for IC, 1.40 for IC-M, 8.54 for EH, and 1.98 for IH, indicating that damage accumulation was an acceleration factor for failure of all groups. At 75 N the probability of survival was not significantly different between groups. A decrease in reliability was observed for all groups at 200 N with no significant differences between IC (81.71%) and IC-M (94.28%), or between EH and IH (0%) which presented the lowest values. EH failures were primarily restricted to the screw, while IH involved screw and implant fracture. IC and IC-M were restricted to prosthetic failures (fracture and bending). CONCLUSIONS Narrow implants with external or internal hexagon connections presented the lowest reliability at high loads compared to internal conical connections. Failure modes differed among connections.
Collapse
Affiliation(s)
- Dimorvan Bordin
- Prosthodontic and Periodontology Department, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil.,Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY
| | - Lukasz Witek
- Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY
| | - Vinícius P Fardin
- Department of Prosthodontics, Bauru College of Dentistry, University of São Paulo, Bauru, Brazil
| | - Estevam A Bonfante
- Department of Prosthodontics, Bauru College of Dentistry, University of São Paulo, Bauru, Brazil
| | - Paulo G Coelho
- Department of Biomaterials and Biomimetics, College of Dentistry, New York University, New York, NY.,Hansjörg Wyss Department of Plastic Surgery, New York University School of Medicine, New York, NY
| |
Collapse
|
24
|
Macedo JP, Pereira J, Vahey BR, Henriques B, Benfatti CAM, Magini RS, López-López J, Souza JCM. Morse taper dental implants and platform switching: The new paradigm in oral implantology. Eur J Dent 2016; 10:148-154. [PMID: 27011755 PMCID: PMC4784146 DOI: 10.4103/1305-7456.175677] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
The aim of this study was to conduct a literature review on the potential benefits with the use of Morse taper dental implant connections associated with small diameter platform switching abutments. A Medline bibliographical search (from 1961 to 2014) was carried out. The following search items were explored: “Bone loss and platform switching,” “bone loss and implant-abutment joint,” “bone resorption and platform switching,” “bone resorption and implant-abutment joint,” “Morse taper and platform switching.” “Morse taper and implant-abutment joint,” Morse taper and bone resorption,” “crestal bone remodeling and implant-abutment joint,” “crestal bone remodeling and platform switching.” The selection criteria used for the article were: meta-analysis; randomized controlled trials; prospective cohort studies; as well as reviews written in English, Portuguese, or Spanish languages. Within the 287 studies identified, 81 relevant and recent studies were selected. Results indicated a reduced occurrence of peri-implantitis and bone loss at the abutment/implant level associated with Morse taper implants and a reduced-diameter platform switching abutment. Extrapolation of data from previous studies indicates that Morse taper connections associated with platform switching have shown less inflammation and possible bone loss with the peri-implant soft tissues. However, more long-term studies are needed to confirm these trends.
Collapse
Affiliation(s)
- José Paulo Macedo
- School of Dentistry, Universidade Fernando Pessoa (UFP), Porto, 4249-004, Portugal
| | - Jorge Pereira
- School of Dentistry, Universidade Fernando Pessoa (UFP), Porto, 4249-004, Portugal
| | - Brendan R Vahey
- Herman Ostrow School of Dentistry of USC, 925 W 34 St. Los Angeles, CA 90089, USA.,School of Dentistry (ODT), Federal University of Santa Catarina (UFSC), Florianopolis/SC, 88040-900, Brazil
| | - Bruno Henriques
- School of Dentistry (ODT), Federal University of Santa Catarina (UFSC), Florianopolis/SC, 88040-900, Brazil
| | - Cesar A M Benfatti
- School of Dentistry (ODT), Federal University of Santa Catarina (UFSC), Florianopolis/SC, 88040-900, Brazil
| | - Ricardo S Magini
- School of Dentistry, Universidade Fernando Pessoa (UFP), Porto, 4249-004, Portugal
| | - José López-López
- Oral Health and Masticatory System Group (Bellvitge Biomedical Research Group), School of Dentistry, L'Hospitalet de Llobregat, Universitat de Barcelona, 402 4270, Barcelona, Spain
| | - Júlio C M Souza
- School of Dentistry (ODT), Federal University of Santa Catarina (UFSC), Florianopolis/SC, 88040-900, Brazil
| |
Collapse
|
25
|
Goiato MC, Shibayama R, Gennari Filho H, de Medeiros RA, Pesqueira AA, dos Santos DM, de Araújo CA. Stress distribution in implant-supported prostheses using different connection systems and cantilever lengths: digital photoelasticity. J Med Eng Technol 2016; 40:35-42. [PMID: 26783652 DOI: 10.3109/03091902.2015.1127440] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Photoelastic analysis was used to evaluate the biomechanical behaviour of implant-supported, double-screwed crowns with different connection systems and cantilever lengths. Three models were made in PL-2 photoelastic resin and divided into six groups, on the basis of the implant connection system (external hexagon [EH] or Morse taper [MT]), type of abutment (Mini Pilar [Neodent, Curitiba, Paraná, Brazil] or "UCLA") and number of crowns in the cantilever (one or two). The implant-prosthesis unit was placed in a circular polariscope. Occlusal surfaces of the crowns were subjected to 100-N loads in the axial and oblique (45°) directions in a universal testing machine (EMIC). Generated stresses were recorded and analysed qualitatively in a graphics program (Adobe Photoshop). Under axial loading, all of the groups had similar numbers of fringes, which were increased when the crowns were subjected to oblique loading. The highest number of fringes was found during oblique loading in the EH + Mini Pilar group. In conclusion, although the type of implant connection system did not have a direct influence on the stress distribution for axial loading, the cantilever length did have a direct influence on stress distribution. Models with two crowns in the cantilever showed more stress, with a greater concentration of force on the cervical part of the implant.
Collapse
Affiliation(s)
- Marcelo Coelho Goiato
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Ricardo Shibayama
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Humberto Gennari Filho
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Rodrigo Antonio de Medeiros
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Aldiéris Alves Pesqueira
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Daniela Micheline dos Santos
- a Department of Dental Materials and Prosthodontics , Araçatuba Dental School, UNESP , Araçatuba , São Paulo , Brazil
| | - Cleudmar Amaral de Araújo
- b Department of Mechanical Projects , Federal University of Uberlândia , Uberlândia , Minas Gerais , Brazil
| |
Collapse
|
26
|
Siadat H, Pirmoazen S, Beyabanaki E, Alikhasi M. Does Abutment Collar Length Affect Abutment Screw Loosening After Cyclic Loading? J ORAL IMPLANTOL 2015; 41 Spec No:346-51. [PMID: 26237093 DOI: 10.1563/aaid-joi-d-d-14-00021] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A significant vertical space that is corrected with vertical ridge augmentation may necessitate selection of longer abutments, which would lead to an increased vertical cantilever. This study investigated the influence of different abutment collar heights on single-unit dental implant screw-loosening after cyclic loading. Fifteen implant-abutment assemblies each consisted of an internal hexagonal implant were randomly assigned to 3 groups: Group1, consisting of 5 abutments with 1.5 mm gingival height (GH); Group2, 5 abutments with 3.5 mm GH; and Group3, 5 abutments with 5.5 mm GH. Each specimen was mounted in transparent auto-polymerizing acrylic resin block, and the abutment screw was tightened to 35 Ncm with an electric torque wrench. After 5 minutes, initial torque loss (ITL) was recorded for all specimens. Metal crowns were fabricated with 45° occlusal surface and were placed on the abutments. A cyclic load of 75 N and frequency of 1 Hz were applied perpendicular to the long axis of each specimen. After 500 000 cycles, secondary torque loss (STL) was recorded. One-way ANOVA analysis was used to evaluate the effects of abutment collar height before and after cyclic loading. One-way ANOVA showed that ITL among the groups was not significantly different (P = .52), while STL was significantly different among the groups (P = .008). Post-hoc Tukey HSD tests showed that STL values were significantly different between the abutments with 1.5 mm GH (Group1) and with 5.5 mm GH (Group3) (P = .007). A paired comparison t-test showed that cyclic loading significantly influenced the STL in comparison with the ITL in each group. Within the limitations of this study, it can be concluded that increase in height of the abutment collar could adversely affect the torque loss of the abutment screw.
Collapse
Affiliation(s)
- Hakimeh Siadat
- 1 Dental Implant Research Center and Department of Prosthodontics, Tehran University of Medical Sciences, School of Dentistry, Tehran, Iran
| | - Salma Pirmoazen
- 2 Dental Implant Research Center and Department of Endodontics, Tehran University of Medical Sciences, School of Dentistry, Tehran, Iran
| | - Elaheh Beyabanaki
- 1 Dental Implant Research Center and Department of Prosthodontics, Tehran University of Medical Sciences, School of Dentistry, Tehran, Iran
| | - Marzieh Alikhasi
- 1 Dental Implant Research Center and Department of Prosthodontics, Tehran University of Medical Sciences, School of Dentistry, Tehran, Iran
| |
Collapse
|
27
|
Abstract
Dental implant-abutment connection design has developed into the use of a conical, shank and socket connection between the implant abutment and fixture. The connection between these two elements is, in effect, a conical wedge that may exert lateral forces under load that may result in fracture of the coronal implant socket fixture walls. This study evaluated the axial loading on a conical connection and found that axial loads were well tolerated but off-axial loads were not. Fracture of the implant coronal socket fixture wall occurred under off-axial loading.
Collapse
|
28
|
Palaska I, Tsaousoglou P, Vouros I, Konstantinidis A, Menexes G. Influence of placement depth and abutment connection pattern on bone remodeling around 1-stage implants: a prospective randomized controlled clinical trial. Clin Oral Implants Res 2014; 27:e47-56. [DOI: 10.1111/clr.12527] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/22/2014] [Indexed: 01/10/2023]
Affiliation(s)
- Iro Palaska
- Molecular Immunopharmacology and Drug Discovery Laboratory; Department of Integrative Physiology and Pathobiology; Tufts University School of Medicine; Boston MA USA
| | - Phoebus Tsaousoglou
- Department of Preventive Dentistry; Periodontology & Implant Biology; School of Dentistry; Aristotle University of Thessaloniki; Thessaloniki Greece
| | - Ioannis Vouros
- Department of Preventive Dentistry; Periodontology & Implant Biology; School of Dentistry; Aristotle University of Thessaloniki; Thessaloniki Greece
| | - Antonis Konstantinidis
- Department of Preventive Dentistry; Periodontology & Implant Biology; School of Dentistry; Aristotle University of Thessaloniki; Thessaloniki Greece
| | - George Menexes
- Department of Agronomy; School of Agriculture; Aristotle University of Thessaloniki; Thessaloniki Greece
| |
Collapse
|
29
|
Mangano C, Iaculli F, Piattelli A, Mangano F. Fixed restorations supported by Morse-taper connection implants: a retrospective clinical study with 10-20 years of follow-up. Clin Oral Implants Res 2014; 26:1229-36. [PMID: 24954285 DOI: 10.1111/clr.12439] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2014] [Indexed: 01/30/2023]
Abstract
OBJECTIVES Rehabilitation with implant-supported fixed prostheses is a predictable modality to restore lost function and esthetics; however, fixed restorations are subject to biological and prosthetic complications, which may represent a problem in the long-term. The aim of this study was to evaluate the long-term survival and complication rates of fixed restorations supported by Morse-taper connection implants. MATERIALS AND METHODS Between January 1992 and December 2002, 49 patients (age range 22-70 years), were included in this study. The restorations involved 58 fixed reconstructions (15 single crowns [SCS], 29 partial prostheses, 14 full-arches), supported by 178 Morse-taper connection implants with a follow-up ranging from 10 to 20 years. Outcomes such as implant survival, marginal bone loss, frequency of biological and prosthetic complications as well as "complication-free" survival of restorations were investigated. RESULTS The 20-year overall cumulative implant survival was 97.2%. A few biological (3.4%) and prosthetic (10.3%) complications were reported. The "complication-free" survival rate of restorations was 85.5%. No statistically significant differences were observed among patients' gender, age, smoking or parafunctional habits, prosthesis site and type. CONCLUSIONS Satisfactory "complication-free" survival rates can be achieved after 20 years for fixed restorations supported by Morse-taper connection implants, with minimal marginal bone loss and complications.
Collapse
Affiliation(s)
- Carlo Mangano
- Department of Surgical and Morphological Science, Dental School, University of Varese, Varese, Italy
| | - Flavia Iaculli
- Department of Medical, Oral and Biotechnological Sciences, Dental School, University of Chieti-Pescara, Chieti, Italy
| | - Adriano Piattelli
- Department of Medical, Oral and Biotechnological Sciences, Dental School, University of Chieti-Pescara, Chieti, Italy
| | - Francesco Mangano
- Department of Surgical and Morphological Science, Dental School, University of Varese, Varese, Italy
| |
Collapse
|
30
|
Comparative Histological and Histomorphometrical Evaluation of Marginal Bone Resorption Around External Hexagon and Morse Cone Implants. IMPLANT DENT 2014; 23:270-6. [DOI: 10.1097/id.0000000000000089] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Delben JA, Barão VA, Ferreira MB, da Silva NR, Thompson VP, Assunção WG. Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems. Dent Mater 2014; 30:408-16. [DOI: 10.1016/j.dental.2014.01.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2013] [Revised: 01/07/2014] [Accepted: 01/14/2014] [Indexed: 11/16/2022]
|
32
|
Rinke S, Roediger M, Eickholz P, Lange K, Ziebolz D. Technical and biological complications of single-molar implant restorations. Clin Oral Implants Res 2014; 26:1024-30. [PMID: 24673690 DOI: 10.1111/clr.12382] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/22/2014] [Indexed: 11/28/2022]
Abstract
OBJECTIVES Retrospective evaluation of the biological and technical complications in implant-supported single-tooth molar restorations performed in a private practice after functional periods of ≥4 years. MATERIAL AND METHODS Sixty-five patients (34 females, age 51.7 ± 10.6 years) with 112 implants received annual follow-up examinations and participated in a maintenance program. The survival (in situ) and success (complication-free) rates of implants and superstructures were evaluated. Time-dependent peri-implantitis rates were calculated, and the influencing factors were identified using a multiple Cox regression. RESULTS The implant survival rate was 100%. Three of 112 crowns required replacement (prosthetic survival rate = 98.1%). Thirty technical complications were observed: loss of retention (16), ceramic fracture (10), and screw loosening (4). The success rate of the superstructures was 79.0% after 7 years. Overall, 9.2% of the patients developed peri-implantitis (probing depth ≥5 mm, BOP, suppuration, bone loss ≥3.5 mm); (smokers: 41.6%, non-smokers: 1.8%). After 7 years, the time-dependent implant success rate (free of peri-implantitis) was 100% for non-smokers and 58.6% for smokers. Multiple analysis showed a significant effect of smoking (hazard ratio, 19.5; P = 0.008) on peri-implantitis. CONCLUSIONS Implants with cemented single-tooth restorations in the molar region constitute a reliable treatment in private practice. Smokers have a significantly increased peri-implantitis rate.
Collapse
Affiliation(s)
| | - Matthias Roediger
- Department of Prosthodontics, Georg-August-University, Goettingen, Germany
| | - Peter Eickholz
- Department of Periodontology, Center for Dental Medicine, Oral and Maxillofacial Medicine, Johann Wolfgang Goethe-University, Frankfurt/Main, Germany
| | - Katharina Lange
- Department of Medical Statistics, Georg-August-University, Goettingen, Germany
| | - Dirk Ziebolz
- Department of Operative Dentistry, Preventive Dentistry and Periodontology, Georg-August-University, Göttingen, Germany
| |
Collapse
|
33
|
Maiorana C, Farronato D, Pieroni S, Cicciu M, Andreoni D, Santoro F. A Four-Year Survival Rate Multicenter Prospective Clinical Study on 377 Implants: Correlations Between Implant Insertion Torque, Diameter, and Bone Quality. J ORAL IMPLANTOL 2014; 41:e60-5. [PMID: 24517193 DOI: 10.1563/aaid-joi-d-13-00206] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this study was to evaluate the survival rate and incidence of prosthetic complications in 377 implants with a double octagon connection. Furthermore, the correlations among implant dimensions (diameter and length), bone quality, and insertion torque were investigated. A 4-year multicenter prospective clinical study was designed to evaluate the survival rate of 377 dental implants inserted in 189 patients between January 2004 and April 2010. After an average follow-up of 46 months, the implant survival rate was 99.7%, and the incidence of complication was 0.53%. Moreover, insertion torque was statistically related in a significant way to implant diameter. The connection system seemed to reduce the risk that the prosthetic component screw would loosen. Within the limits of this study, it was observed that a wider diameter corresponded to a higher implant primary stability. Implant length did not seem to be critical in obtaining higher primary stability.
Collapse
Affiliation(s)
- Carlo Maiorana
- 1 Oral Surgery and Implantology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, University of Milan, Milan, Italy
| | - Davide Farronato
- 2 Department of Implantology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, University of Milan, Milan, Italy
| | - Stefano Pieroni
- 2 Department of Implantology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, University of Milan, Milan, Italy
| | - Marco Cicciu
- 3 Department of Human Pathology, Dental School, University of Messina, Messina, Italy
| | - Dario Andreoni
- 2 Department of Implantology, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, University of Milan, Milan, Italy
| | - Franco Santoro
- 4 Dental Clinic, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico Milano, University of Milan, Milan, Italy
| |
Collapse
|
34
|
Alves DCC, Carvalho PSPD, Martinez EF. In Vitro Microbiological Analysis of Bacterial Seal at the Implant-Abutment Interface Using Two Morse Taper Implant Models. Braz Dent J 2014; 25:48-53. [DOI: 10.1590/0103-6440201302178] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Accepted: 02/12/2014] [Indexed: 11/22/2022] Open
Abstract
The objective of this study was to evaluate the bacterial seal at the implant-abutment interface using two morse taper implant models, by means of an in vitro microbiological analysis. For that were used 15 implants with mini-abutments tightened by friction, no screws (Group 1); and 30 implants with screw-tightened abutments, of which 15 received 20 N.cm of closing torque (Group 2) and the other 15 received 30 N.cm (Group 3). Microbiological analysis was carried out using colonies of Escherichia coli transported directly from a culture dish to the prosthetic component. Friction implants (Group 1) were activated by tapping and a torque wrench was used for screw-tightened implants (Groups 2 and 3). Each abutment/implant set was immersed in test tubes containing 5 mL of brain-heart infusion broth and incubated at 37 °C for 14 days, observed daily for the presence of contamination. A statistically significant difference was observed regarding the number of contaminated implants. There was greater contamination in Group 2 implants (p<0.05), with no statistically significant difference between the other groups (Group 1 = 20% and Group 3 = 0%). It was concluded that there was no significant difference in in vitro bacterial sealing between implants with mini-abutments tightened by friction without screws and implants with screw-tightened abutments with 30 N.cm of closing torque. The difference in closing torque altered the in vitro sealing ability of the tested abutments, with a greater contamination for components that received a closing torque of 20 N.cm.
Collapse
|
35
|
Mangano C, Levrini L, Mangano A, Mangano F, Macchi A, Caprioglio A. Esthetic Evaluation of Implants Placed after Orthodontic Treatment in Patients with Congenitally Missing Lateral Incisors. J ESTHET RESTOR DENT 2013; 26:61-71. [DOI: 10.1111/jerd.12081] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Carlo Mangano
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| | - Luca Levrini
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| | - Alessandro Mangano
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| | - Francesco Mangano
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| | - Aldo Macchi
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| | - Alberto Caprioglio
- Department of Surgical and Morphological Sciences; University of Insubria; Varese Italy
| |
Collapse
|
36
|
Ugurel CS, Steiner M, Isik-Ozkol G, Kutay O, Kern M. Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections. Clin Oral Implants Res 2013; 26:137-42. [PMID: 24313278 DOI: 10.1111/clr.12303] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/23/2013] [Indexed: 11/30/2022]
Abstract
OBJECTIVE The screwless morse taper (SMT) implant-abutment connection is an alternative to conventional external or internal screw-retained (ISR) connections. The aim of this in vitro study was to evaluate mechanical resistance of the SMT connection and to compare it with three different ISR connections. MATERIALS AND METHODS Four implant systems were tested in this study: SMT system; Tasarimmed Octo (Istanbul, Turkey), ISR systems; Straumann Bone Level (Basel, Switzerland), Biohorizons Internal (Birmingham, AL, USA), and Dentsply Friadent Xive (Mannheim, Germany). Overall, 64 specimens with stylized single crowns were prepared: 32 for dynamic loading (DL) and 32 for static loading (SL). DL was carried out using a chewing simulator with 120 N at 1.75 Hz for 1.2 × 10(6) cycles, and SL was performed with a universal testing machine at a crosshead speed of 2 mm/min with an angulation of 30°. Cycles until failure from DL and fracture/bending loads at SL were recorded. Statistical analyses were made with Dunn's multiple comparison. RESULTS Median cycles until failure in DL were as follows: Octo 86,354 (24,810-153,875), Straumann 1,200,000 (1,156,618-1,200,000), Biohorizons 539,719 (437,224-858,732), Xive 139,411 (139,411-139,411). Median fracture/bending loads in Newton at SL were as follows: Octo 429.6 (404.5-482.7), Straumann 574.6 (544.6-629.9), Biohorizons 548.7 (532.9-567.3), Xive 431.5 (412.5-520.5). There were significant differences between the implant systems under both loading conditions (P ≤ 0.05) revealing that the Octo implant system's SMT connection showed significantly lower cycles to failures and lower fracture/bending loads compared with the ISR connections of the Straumann and Biohorizons implant systems. However, there was no significant difference compared with the Xive implant system. CONCLUSION The mechanical resistance of the screwless morse taper implant system is lower than that of the ISR implant systems that might result in more frequent clinical complications.
Collapse
Affiliation(s)
- Cihan Sadi Ugurel
- Department of Prosthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey
| | | | | | | | | |
Collapse
|
37
|
Frisch E, Ziebolz D, Ratka-Krüger P, Rinke S. Double crown-retained maxillary overdentures: 5-year follow-up. Clin Implant Dent Relat Res 2013; 17:22-31. [PMID: 23679159 DOI: 10.1111/cid.12087] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
BACKGROUND There is a lack of data concerning implant-supported overdentures (IODs) retained by double crowns in the edentulous maxilla. PURPOSE To perform a retrospective evaluation of clinical outcomes (survival/success rates) of maxillary overdentures retained on four implants via double crowns. MATERIAL AND METHODS Between 1993 and 2011, 28 patients with edentulous maxillae were restored with overdentures supported by four implants with a Morse taper connection (Ankylos, Dentsply Friadent, Mannheim, Germany) and double crowns according to the Marburg Double Crown (MDC) technique in a private practice. For retrospective evaluation of implant and prosthetic survival (in situ criterion) and success (event-free observational period), only patients attending a professional maintenance program were included (n = 20). RESULTS Twenty patients (13 female/ seven male, mean age: 63.45 ± 7.18 years) with 80 implants met the inclusion criteria. The mean follow-up period was 5.64 ± 3.50 years. One implant was lost (cumulative survival rate: 98.75%). Eight implants (10.1%) in two patients (10%) showed peri-implantitis; both patients were active smokers (cumulative success rate: 88.75%). All dentures were still functional (prosthetic survival rate 100%) at the time of investigation. Technical maintenance procedures (e.g., abutment loosening, screw loosening, acrylic fracture or relining) were required at a rate of 0.222/patient-year. CONCLUSIONS Within the limitations of this study, we conclude that MDC-IODs are a promising treatment alternative for edentulous maxillae offering high implant and prosthesis survival rates > 98% and a limited incidence of biological and technical complications after a mean observational period of >5 years.
Collapse
Affiliation(s)
- Eberhard Frisch
- Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Goettingen, Goettingen, Germany
| | | | | | | |
Collapse
|
38
|
Mangano FG, Shibli JA, Sammons RL, Iaculli F, Piattelli A, Mangano C. Short (8-mm) locking-taper implants supporting single crowns in posterior region: a prospective clinical study with 1-to 10-years of follow-up. Clin Oral Implants Res 2013; 25:933-40. [DOI: 10.1111/clr.12181] [Citation(s) in RCA: 51] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/28/2013] [Indexed: 11/30/2022]
Affiliation(s)
| | - Jamil Awad Shibli
- Oral Implantology Clinic; Department of Periodontology; Dental Research Division; Guarulhos University; Guarulhos Sao Paulo Brazil
| | | | - Flavia Iaculli
- Dental School; University of Chieti-Pescara; Chieti Italy
| | - Adriano Piattelli
- Department of Medical; Oral and Biotechnological Sciences; Dental School; University of Chieti-Pescara; Chieti Italy
| | - Carlo Mangano
- Oral Surgery Unit; Department of Surgical and Morphological Science; Dental School; University of Insubria; Varese Italy
| |
Collapse
|
39
|
Coelho Goiato M, Pesqueira AA, Falcón-Antenucci RM, Dos Santos DM, Haddad MF, Bannwart LC, Moreno A. Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections. Acta Odontol Scand 2013; 71:283-8. [PMID: 22486241 DOI: 10.3109/00016357.2012.672823] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. MATERIALS AND METHODS Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). RESULTS Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. CONCLUSION In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading.
Collapse
Affiliation(s)
- Marcelo Coelho Goiato
- Department of Dental Materials and Prosthodontics, Araçatuba School of Dentistry, São Paulo State University-UNESP, Araçatuba, São Paulo, Brazil.
| | | | | | | | | | | | | |
Collapse
|
40
|
Sailer I, Mühlemann S, Zwahlen M, Hämmerle CHF, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res 2012; 23 Suppl 6:163-201. [DOI: 10.1111/j.1600-0501.2012.02538.x] [Citation(s) in RCA: 192] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Irena Sailer
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; University of Zurich; Switzerland
| | - Sven Mühlemann
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; University of Zurich; Switzerland
| | - Marcel Zwahlen
- Institute of Social and Preventive Medicine; University of Bern; Bern; Switzerland
| | - Christoph H. F. Hämmerle
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; University of Zurich; Switzerland
| | - David Schneider
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science; University of Zurich; Switzerland
| |
Collapse
|
41
|
|
42
|
Freitas-Júnior AC, Almeida EO, Bonfante EA, Silva NR, Coelho PG. Reliability and failure modes of internal conical dental implant connections. Clin Oral Implants Res 2012; 24:197-202. [DOI: 10.1111/j.1600-0501.2012.02443.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/29/2012] [Indexed: 11/30/2022]
Affiliation(s)
- Amilcar C. Freitas-Júnior
- Postgraduate Program in Dentistry; School of Health Sciences; Potiguar University - UnP; Natal; RN; Brazil
| | - Erika O. Almeida
- Department of Dental Materials and Prosthodontics; São Paulo State University; Araçatuba School of Dentistry; Araçatuba; São Paulo; Brazil
| | - Estevam A. Bonfante
- Postgraduate Program in Dentistry; UNIGRANRIO University-School of Health Sciences; Duque de Caxias; RJ; Brazil
| | - Nelson R.F.A. Silva
- Department of Prosthodontics; New York University College of Dentistry; New York; NY; USA
| | - Paulo G. Coelho
- Department of Biomaterials and Biomimetics; Director for Research, Department of Periodontology and Implant Dentistry; New York University College of Dentistry; New York; NY; USA
| |
Collapse
|
43
|
Guerra M, Vozza I, Quaranta A. Histological Evaluation of Peri-Implant Soft Tissues in Immediately Loaded Implants Featuring Different Implant-Abutment Connections: A Preliminary Study. EUR J INFLAMM 2012. [DOI: 10.1177/1721727x1201000110] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The aim of the present study is to evaluate the peri-implant soft tissues and the amount of inflammatory cells around two different implant-abutment connections (self-locking conical connection with platform switching and screwed connection with standard abutment and internal anti-rotational system). Histological analysis was made of 14 implants, 7 with self-locking Morse tapered connection (experimental group A) and 7 with screw-retained anti-rotational connection (control group B). Sixty days after non-functional immediate loading, peri-implant tissue biopsies were performed. In the samples taken from the experimental group the peri-implant connective tissue consisted of a greater density of collagen and fibroblasts compared to the connective tissue of the control group. The experimental group specimens showed less inflammatory infiltrate close to the self-locking tapered connection compared to the tissues around the screw-retained connection. The SEM observations showed less microgap in the self-locking conical connection than in the screw connections with standard abutment and internal anti-rotational system. The presence of connective tissue with few inflammatory cells and the absence of inflammatory infiltrate, in self-locking conical connection implants is due to the minimal size of the implant-abutment microgap that does not allow the passage of fluids and bacteria from the oral cavity to the implant thus preventing tissue inflammation.
Collapse
Affiliation(s)
| | - I. Vozza
- Oral and Maxillofacial Department, Sapienza University of Rome, Rome Italy
| | - A. Quaranta
- Oral and Maxillofacial Department, Sapienza University of Rome, Rome Italy
| |
Collapse
|
44
|
Oderich E, Boff LL, Cardoso AC, Magne P. Fatigue resistance and failure mode of adhesively restored custom implant zirconia abutments. Clin Oral Implants Res 2011; 23:1360-8. [DOI: 10.1111/j.1600-0501.2011.02360.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/18/2011] [Indexed: 12/28/2022]
Affiliation(s)
- Elisa Oderich
- Department of Restorative Sciences; Herman Ostrow School of Dentistry; University of Southern California; Los Angeles; CA; USA
| | - Luís Leonildo Boff
- Department of Restorative Sciences; Herman Ostrow School of Dentistry; University of Southern California; Los Angeles; CA; USA
| | - Antônio Carlos Cardoso
- Department of Dentistry; Federal University of Santa Catarina - UFSC; Florianópolis; SC; Brazil
| | - Pascal Magne
- The Don & Sybil Harrington Foundation, Division of Restorative Sciences; The Herman Ostrow School of Dentistry; University of Southern California; Los Angeles; CA; USA
| |
Collapse
|
45
|
Vaz P, Gallas MM, Braga AC, Sampaio-Fernandes JC, Felino A, Tavares P. IL1 gene polymorphisms and unsuccessful dental implants. Clin Oral Implants Res 2011; 23:1404-13. [PMID: 22092925 DOI: 10.1111/j.1600-0501.2011.02322.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/11/2011] [Indexed: 12/23/2022]
Abstract
OBJECTIVES This study aimed to analyse the association between polymorphisms in the IL1 gene cluster and failure of dental implants in a Portuguese population. MATERIAL AND METHODS A total of 155 Caucasian Portuguese subjects were divided into two groups: 100 with successful dental implants and 55 with unsuccessful dental implants. DNA was obtained through an oral mucosa scraping. PCR was used to identify the polymorphisms: single nucleotide changes in positions -889 of IL1A gene and +3953 of IL1B gene. RESULTS The prevalence of the polymorphisms -889IL1A gene and +3953IL1B gene, determined by the positive result of TGP (Genetic Test for Periodontitis; CGC, Genetics, Portugal), in the studied population rehabilitated with dental implants was of 33.50%. Allele 1 of the IL1B gene was the most prevalent (62.20%), followed by allele 1 of the IL1A gene (54.80%) and the least frequent was allele 2 of IL1B gene (37.40%). Success of dental implants was mainly associated with a negative TGP result, whereas no success was found to be related to a positive result. There were no statistically significant differences between the alleles 1 and 2 of the genes IL1A and IL1B and the tobacco and alcohol consumption for the success or no success of the dental implants. CONCLUSIONS The alleles 1 and 2 of IL1A gene and the alleles 1 and 2 of IL1B gene were statistically associated with the success or no success of the dental implants. Tobacco habit and alcohol consumption showed no statistically significant association with success or no success of the dental implants.
Collapse
Affiliation(s)
- P Vaz
- Serviço de Genética Médica e Orofacial, Faculdade de Medicina Dentária, Universidade do Porto, Porto, Portugal.
| | | | | | | | | | | |
Collapse
|
46
|
Mangano F, Mangano C, Ricci M, Sammons RL, Shibli JA, Piattelli A. Single-tooth Morse taper connection implants placed in fresh extraction sockets of the anterior maxilla: an aesthetic evaluation. Clin Oral Implants Res 2011; 23:1302-7. [PMID: 22092363 DOI: 10.1111/j.1600-0501.2011.02307.x] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/26/2011] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this retrospective study was to evaluate the aesthetic outcome of single-tooth Morse taper connection implants placed in fresh extraction sockets of the anterior maxilla, by means of the pink aesthetic/white aesthetic score (PES/WES) index. MATERIALS AND METHODS Twenty-six adult patients (18 men, 8 women, aged between 20 and 62 years; average: 48.7 years) who were treated with an immediate, single-tooth Morse taper connection implant (Leone Implant System(R) , Florence, Italy) in the aesthetic area of the anterior maxilla, were enrolled in this retrospective study. An independent calibrated examiner applied the PES/WES index to 26 single-tooth implant-supported restorations, respectively, 3 months and 2 years after implant placement. RESULTS No implants were lost. All 26 anterior maxillary single-tooth implants fulfilled the established success criteria for dental implants with regard to osseointegration, including the absence of pain, suppuration, clinically detectable implant mobility, peri-implant radiolucency and prosthetic complications at the implant-abutment interface, with an overall implant-crown success of 100.0%. At the 2-year examination, the mean DIB was 0.44 ± 0.14 mm (95% CI: 0.41-0.47); the mean total PES/WES was 14.30 ± 2.78 (range 8-19); the mean PES was 7.30 ± 1.78 (range 4-10) and the mean WES was 7.00 ± 1.35 (range 4-10). CONCLUSIONS The immediate placement of single-tooth Morse taper connection implants in the anterior maxilla seems to represent a successful procedure, from an aesthetic point of view. Further studies are needed to evaluate the aesthetic outcome of single-tooth Morse taper connection implants placed in fresh extraction sockets of the anterior maxilla.
Collapse
|
47
|
De Paolis G, Quaranta A, Zappia S, Vozza I, Quaranta M. Valutazione clinica e microbiologica di impianti a connessione conometrica rispetto a impianti a connessione esagonale: caso clinico. DENTAL CADMOS 2011. [DOI: 10.1016/j.cadmos.2010.12.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
48
|
Chaar MS, Att W, Strub JR. Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review. J Oral Rehabil 2011; 38:697-711. [PMID: 21395638 DOI: 10.1111/j.1365-2842.2011.02209.x] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The aim of the article is to assess the current literature in terms of the prosthetic outcome of cement-retained implant-supported fixed restorations, as well as to determine the type of cement that can be recommended for clinical application. A review of the literature published up to May 2010 was conducted to identify clinical studies about cement-retained implant-supported fixed restorations. The search strategy applied was a combination of MeSH terms and free text words, including the following keywords: implants, implant-supported fixed dental prostheses (FDPs), bridges, implant-supported single crowns (SCs), cement-retained, cement fixation, cement, cementation, cement failure, retention, and loss of retention, technical complications, mechanical complications, prosthetic complication, retrievability and maintenance. Thirty-two studies met the inclusion criteria. The studies were divided into two categories: 15 short-term clinical studies with an observation period of less than 5 years, and 17 long-term clinical studies with an observation period of 5 years and more. The most common technical complications of cement-retained implant-supported fixed restorations were loss of retention, chipping and abutment screw loosening. The results of the current review revealed no guidelines about cement or cementation procedures. It may be stated that despite the questionable retrievability of cement-retained implant-supported fixed restorations, this treatment modality is a reliable and effective option, especially for implant-supported SCs and short-span FDPs. The literature does not provide accurate information about the clinical outcome of cement-retained implant-supported fixed restorations nor about the ideal type of cement that facilitates stability and maintains retrievability. Standardised randomised clinical trials will provide valuable information to this issue.
Collapse
Affiliation(s)
- M S Chaar
- Department of Prosthodontics, School of Dentistry, Albert-Ludwigs University, Freiburg, Germany
| | | | | |
Collapse
|
49
|
Mangano C, Mangano F, Shibli JA, Ricci M, Sammons RL, Figliuzzi M. Morse taper connection implants supporting "planned" maxillary and mandibular bar-retained overdentures: a 5-year prospective multicenter study. Clin Oral Implants Res 2011; 22:1117-1124. [PMID: 21251077 DOI: 10.1111/j.1600-0501.2010.02079.x] [Citation(s) in RCA: 37] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVES In contrast to the excellent long-term outcomes described for implant-supported mandibular overdentures, less favorable long-term survival and success rates have been reported for maxillary implants supporting overdentures. The aim of this study was to evaluate the treatment outcome of "planned" bar-retained maxillary and mandibular overdentures supported by Morse taper connection implants, investigating implant survival, peri-implant tissue health, marginal bone resorption and prosthetic complications. MATERIAL AND METHODS Over a 2-year period, 60 patients were enrolled in this study, in four different clinical centers. The overdentures (maxilla 38, mandible 34) were planned with support from four implants anchored on a bar. A total of 288 Morse taper connection implants (Leone Implant System(®)) were inserted (152 maxilla, 136 mandible). Implants were evaluated 5 years after insertion. Success criteria included the absence of pain, suppuration or clinical mobility, the distance between implant shoulder and first crestal bone-implant contact (DIB) <2 mm and no exudate history. RESULTS The overall 5-year implant survival rate was 98% (maxilla 97.4%, mandible 98.6%), with 282 implants still in function. Among these surviving implants, 278 (98.6%) were classified in the success group. At the 5-year examination, the mean DIB was 0.7 mm (±0.53). Few prosthetic complications were reported. CONCLUSIONS With "planned" bar-retained maxillary and mandibular overdentures supported by Morse taper connection implants, satisfactory survival and success rate can be achieved.
Collapse
Affiliation(s)
- Carlo Mangano
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| | - Francesco Mangano
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| | - Jamil Awad Shibli
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| | - Massimiliano Ricci
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| | - Rachel Lilian Sammons
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| | - Michele Figliuzzi
- Dental School, University of Varese, Varese, ItalyPrivate Practice, Como, ItalyDental School, University of Guarulhos, Sao Paulo, BrazilDental School, University of Genova, Genova, ItalyDental School, University of Birmingham, Birmingham, UKDental School, University of Catanzaro, Catanzaro, Italy
| |
Collapse
|
50
|
Mangano C, Mangano F, Shibli JA, Tettamanti L, Figliuzzi M, d'Avila S, Sammons RL, Piattelli A. Prospective evaluation of 2,549 Morse taper connection implants: 1- to 6-year data. J Periodontol 2010; 82:52-61. [PMID: 20653436 DOI: 10.1902/jop.2010.100243] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
BACKGROUND The aim of this study is to evaluate the implant survival, the implant-crown success, and the prosthetic complications of 2,549 Morse taper interference-fit connection implants. METHODS A total of 2,549 Morse taper connection implants were inserted in 893 patients from January 2003 until December 2008. At each annual recall, clinical, radiographic, and prosthetic parameters were assessed. The implant-crown success criteria included the absence of pain, suppuration, and clinical mobility; an average distance between the implant shoulder and the first visible bone contact <2 mm from initial surgery; and the absence of prosthetic complications at the implant-abutment interface. Prosthetic restorations were fixed partial prostheses (462 units); fixed full-arch prostheses (60 units); single crowns (531 units); and overdentures (93 units). RESULTS The cumulative implant survival rate was 98.23% (97.25% maxilla, 99.05% mandible). The implant-crown success was 92.49%. A few prosthetic complications at implant-abutment interface were reported (0.37%). After 6 years, distance between the implant shoulder and the first visible bone contact was 1.10 mm (± 0.30 mm). CONCLUSION The use of Morse taper connection implants represents a successful procedure for the rehabilitation of partially and completely edentulous arches.
Collapse
|